Diaphragm Liquid Pumps MODELS 52 F F 12 FP 21 52 F F 12 FP 21 FEATURES Self priming Dry running Oil-less, non lubricated Suitable for continuous operation Chemical resistent pump materials for aggressive media Drive available for all required voltages in AC and DC TYPICAL APPLICATIONS Chemical industry Medical devices Laboratory and analysis Industrial applications Hygiene Consult factory for customized solutions
+ Diaphragm Liquid Pump 52F 4 ml/min up to 15 m H 2 O 6 m H 2 O 31(1.22) 81(3.19) 4(1.58) 3(1.18) 6x 3(.12) 3.4(.13) 4.9(.19) 26.9(1.6) 29.9(1.18) 5.5(1.99) 3(1.18) 26.9(1.6) 5.4(.21) 47(1.85) 6.5(.26) 1.5(.41) M 5(.2) 3.5(1.2) + 4.9(.19) 52(2.5) 1.5(4.13) 14.5(.57) 21(.83) Option: Kopf mit M5 Gewinde head with M5 threads Drawing 17729 Type PA/ PPS/FKM Carbon/PTFE Part number 12 V DC 5312 5315 5318 24 V DC 5313 5316 5319 Free flow at U n 4 ml/min 4 ml/min 4 ml/min Max. pressure height at U n 4 m H 2 O 4 m H 2 O 4 m H 2 O up to 15 m H 2 O up to 15 m H 2 O up to 1 m H 2 O (dry) 6 m H 2 O 6 m H 2 O 5 m H 2 O Permanent magnet Permanent magnet Permanent magnet 12/24 V DC 12/24 V DC 12/24 V DC Nominal speed 3 rpm 3 rpm 3 rpm Nominal current,4/,2 A,58/,29 A,58/,29 A 1,7/,85 A 1,7/,85 A 1,7/,85 A Power consumption max. 5 W 7 W 7 W A A A IP2 IP2 IP2 EMC protection Basic EMC filter (2L) Basic EMC filter (2L) Basic EMC filter (2L) Ambient temperature to 4 C 15 to 4 C 15 to 4 C Temperature range - medium to 7 C 15 to 7 C 15 to 7 C housing temperature max. 15 C max. 15 C max. 15 C,19 kg,19 kg,19 kg PA PPS Carbon (Ridurid ) Diaphragm FPM PTFE Valves FPM FFPM The technical data are based using a PVC-tubing, Ø 4 x 1,5 mm, 1 m length, 65 Sh. The use of a different tubing will change the flow. curve [ml/min] 45 4 35 Carbon/PTFE PA/ PPS/FKM 53... Stock programme Options: with M5 female thread (PA, PPS) Pulsation damper 3 25 2 15 1 5 5 1 15 2 25 3 Pressure height [m H2O] 2
Diaphragm Liquid Pump 52FZ 85 ml/min up to 15 m H 2 O 5 m H 2 O Drawing 17599 A Type PA/ Part number 12 V DC 5322 24 V DC 5323 Free flow at U n 85 ml/min Max. pressure height at U n 4 m H 2 O up to 15 m H 2 O (dry) 5 m H 2 O Permanent magnet 12/24 V DC Nominal speed 3 rpm Nominal current,8 A/,4 A 3,6 A/1,8 A Power consumption max. 9 W E IP EMC protection EN 5511 Ambient temperature to 4 C Temperature range - medium to 7 C housing temperature max. 86 C,34 kg Configuration Parallel PA Diaphragm Valves The technical data are based using a PVC-tubing, Ø 4 x 1,5 mm, 1 m length, 65 Sh. The use of a different tubing will change the flow. curve [ml/min] 9 8 7 PA/ 53... Stock programme Options: with M5 female thread (PA, PPS) Pulsation damper 6 5 4 3 2 1 5 1 15 2 25 3 Pressure height [m H2O] 3
Diaphragm Liquid Pump F12-Stepper 26 ml/min up to 5 m H 2 O 4 m H 2 O 5 8 Drawing 17762 Type F12-28 Part number 24 V DC without circuit board 712246 24 V DC with circuit board 712242 Control range n1 n2 n3 n4 Free flow at U n 1-9 ml/min 1-4 ml/min 2,5-14 ml/min 5-26 ml/min Max. pressure height* 6 m H 2 O 6 m H 2 O 5 m H 2 O 4 m H 2 O up to 5 m H 2 O up to 5 m H 2 O up to 4 m H 2 O up to 3 m H 2 O (dry) 4 m H 2 O 4 m H 2 O 4 m H 2 O 4 m H 2 O Stepper, bipolar Stepping angle 1,8 24 V DC or 2 V AC** Speed range,2-3 rpm Max. current,8 A 5 A B IP Ambient temperature to 4 C Temperature range - medium to 7 C,63 kg Diaphragm, valves Fixing disk PPS FPM 1.4571 (AISI 316 Ti) The technical data are based using a PVC-tubing, Ø 4 x 1,5 mm, 1 m length, 65 Sh. The use of a different tubing will change the flow. * Pressure higher than indicated can lead to a motor blocking. ** Use a time-lag fuse. curve Drive electronic with 1/8 steps [ml/min] 3 275 F12-28 n2 F12-28 n3 25 F12-28 n4 225 2 175 15 125 1 75 5 25 1 2 3 4 5 6 Pressure height [m H 2O] Drawing L17747 We recommend a cooling of the IC at continous duty (see option below). Option: Cooling bar 29 x 11,5 x 37,5 mm, part no. 298915 Connector cable with plug, 2 mm 14-pole, rocker switch for clockwise and lefthanded running, potentiometer and speed-push-botton, part no. 2972 Pulsation damper (UVS 1) 4
Diaphragm Liquid Pump F12G 9 ml/min (only for intermittent duty) 4(1.58) up to 2 m H 2 O 4 m H 2 O ø4.2(.17) 4.2(.16) ø42(1.65) 6.3(.25) Drawing 176 41(1.62) 5(.2) 32(1.25) 43(1.7).8(.3) 36.8(1.45) 75(2.95) 48(1.89) Type F12G Part number 12 V DC 71217 24 V DC 71225 Free flow at U n 9 ml/min Max. pressure height at U n > 5 m H 2 O up to 2 m H 2 O (dry) 4 m H 2 O Nominal speed Nominal current Power consumption max. EMC protection Permanent magnet 12/24 V DC 3 rpm 2,/1, A 5,4/3,5 A 24 W E IP5 Basic EMC filter (2L + 1C)* Ambient temperature to 4 C Temperature range - medium to 7 C,7 kg PPS Diaphragm, valves FPM Fixing disk 1.4571 (AISI 316 Ti) The technical data are based using a PVC-tubing, Ø 4 x 1,5 mm, 1 m length, 65 Sh. The use of a different tubing will change the flow. * at 24 V DC: 2L only curve [ml/min] 9 8 F12G 7 6 5 4 3 2 1 5 1 15 2 25 3 35 4 45 5 Pressure height [m H2O] 5
Diaphragm Liquid Pump FP21 9 ml/min up to 2 m H 2 O 1,5 m H 2 O 89(3.5) 84(3.31) ø M4(.16) 4x X 8(3.15) 9(.35) 24(.95) 158(6.22) 2(.79) 5(1.97) 1(.39) 1(.39) 6(2.36) 7(2.76) Ansicht X 32(1.26) M4(.16) 9(.35) 8x Drawing 17582 5(1.97) ø7(2.76) 18.5(.73) 23(.91) Type FP 21 Part number 23 V/5 Hz 72141 Free flow at U n 9 ml/min Max. pressure height at U n 3 m H 2 O up to 2 m H 2 O (dry) 1,5 m H 2 O Shaded pole 23 V/5 Hz Nominal speed 26 rpm Nominal current,6 A,7 A Power consumption max. 6 W B IP EMC protection EN 5511 Ambient temperature to 4 C Temperature range - medium to 7 C,7 kg PA, PP Diaphragm Gasket, valves Chlorbutadiene rubber Spring 1.4571 (AISI 316 Ti) The technical data are based using a PVC-tubing, Ø 4 x 1,5 mm, 1 m length, 65 Sh. The use of a different tubing will change the flow. curve [ml/min] 9 8 FP21 7 6 5 4 3 2 1 5 1 15 2 25 3 Pressure height [m H2O] 6
Diaphragm Liquid Pump FP21Z 2,2 l/min up to 2 m H 2 O 1,5 m H 2 O 89(3.5) 24(.95) ø ø42(1.65) 5(1.97) 5(1.97) 1(.39) 1(.39) 9(.35) M4(.16) 8x X 95(3.74) 181(7.13) 6(2.36) Drawing 17581 Ansicht X 32(1.26) 99(3.9) M4(.16) 16 x 32(1.26) 9(.35) 18.5(.73) 23(.91) 95(3.74) Type FP21Z Part number 12 V DC 721151 24 V DC 721152 Free flow at U n 2,2 l/min Max. pressure height at U n 35 m H 2 O up to 2 m H 2 O (dry) 1,5 m H 2 O Nominal speed Nominal current Power consumption max. EMC protection Permanent magnet 12/24 V DC 36/39 rpm 2,1/1,1 A 7,6/5,3 A 26 W E IP5 Basic EMC filter (2L)* Ambient temperature to 4 C Temperature range - medium to 7 C,7 kg Configuration Parallel Diaphragm Gasket, valves Spring curve PA, PP Chlorbutadiene rubber 1.4571 (AISI 316 Ti) The technical data are based using a PVC-tubing, Ø 4 x 1,5 mm, 1 m length, 65 Sh. The use of a different tubing will change the flow. * 2L + 2C at 12 V DC [l/min] 2,4 2,2 FP21Z 2, 1,8 1,6 1,4 1,2 1,,8,6,4,2 5 1 15 2 25 3 Pressure height [m H 2O] 7
Chemical Resistance Chart PP Thermoplastics Elastomers Thermoplastics Elastomers PVC PA PPS Carbon Stainless steel (AISI316) PFTE FPM PP PVC PA PPS Carbon Stainless steel (AISI316) PFTE FPM Acetaldehyde A C A A A A A C A Urea A A A A A A A A A Acetate C C A A A A A C A Uric Acid A A A A A A A A A Acetone A C A A A A A C A Isoprophyl alcohol A A B - A A A A A Aluminium chloride A A C A A C A A A Jodine C C C C A C A A B Aluminium sulfate A A C A A B A A A Kaliumhydroxyde A B A A A A A A C Formic acid A A C A A C A C A Potassium salts A A A A A B A A A Ammonia A A B A A A A C A Ketones C B A A A A A C C Amyl acetate B C C A A A A C A Aqua regia B C C C C C A B C Amyl alcohol B A A A A A A A A Oil, linseed A A A B A A A A C Amyl chloride C C C A A A A B C Magnesium chloride solution A A A A A A A A A Aniline C C C A A B A C B Methanol A A C A A A A C A Arsenic acid A A C A A A A A A Methyl ethyl ketone A C A A A A A C A Ether C C A A A B A C C Lactic acid A B C A A B A A A Ethyl alcohol B C A A - A A C C Sodium chloride A A A A A C A A A Barium hydroxide B A A A A B A A A Sodium hydroxide 4 % A A A A A C A C A Benzaldehyde A C C A A B A C A Sodium hypochlorite <5% B A A A B C A A B Petrol C A A A A A A A C Sodium hypochlorite 12 % B C A A C C A A B Benzoic acid C A C A C B A A C Sodium carbonate A A A A A A A A A Benzene A C C A - A A A B Sodium salt A A A A A - A A A Benzylalcohol A C C A - A A A B Oil, hydraulic C A A C B A A A C Hydrocyanic acid A A C B A B A B A Oil, mineral C A A A A A A A C Bleaching agent A A C C A C A A A Oil, vegatable A C A - A A A A B Boric acid A A B A A A A A A Oil, animal - - - - A A A A B Break liquuid A A C - - - A C A Oleic acid B C B A A B A B B Bromine C C C C C C A A C Oxalic acid A A B A A B A A A Butane C C A A A A A A C Paraffins A A A A A A A B C Butanol A B B A A A A A B Perchloroethylene C C C A A A A B C Calcium hypochlorite A B C A A B A A B Perchloric acid - - C A - B A A B Carbon disulphide C C A A - B - B C Phenol B C C A A B A A B Chlorine, liquid C A C C A C A A C Phosphoric acid, 25 % A - C A - C A A B Chlorobenzene C C B A A B B C C Phtalic acid, 9 % C C - - A A A A A Chloracetic acid C B C A A A A C B Pyridine A C B A A A A C B Chloroform C C C A A A A B C Mercury salts A A - A C C A A A Chromium salts C C A - - B A A C Nitrous acid 1 % A A - - A A A A A Chromic acid 5 % B C C A A B A A B Hydrochloric acid B B C A A C A B C Cyclohexane C C A A A A A B C Sulphurdioxide, wet gas A A A A A A A A A Diesel fuel A A A A A A A A C Sulphuric acid, 3 % A A C A A C A A B Ferric sulfate A A A A A A A A A Sulphuric acid, 75-1% C C C A C C A A B Photograpic solutionsa A A - A A A A B Sulphurtrioxide C A C - C A A A B Acetic acid B C A A A A A C B Hydrogen sulphide A B C A A C A C A Acetic anhydride B C C A A A A C A Soap solution A A A A A A A B A Ethanol B C A A A A A C B Stearic acid, 5 % A B A - A A A A B Ethyl chloride A C A - - A A B A Turpentine B B A A A A A A C Ethylene glycol A A B A A A A A A Tetrahydrofurane C C C A A A A C B Fluoroboric acid, 48 %A A C A A B A A A Toluole C C C A A A A A C Fluor silicium acid A A C A A C A A A Trichloroehtylene B C C A B B A B C Formaldehyde C A C B - A A C A Hydrogen peroxide B A C C C A A A B Formamide A A - - - - A C A Xylene C C C A A A A A C Furfural C C B A A B A C B Zinc chloride A A A A A C A A A Tannic acid A B A A A A A B B Citric acid A B A A A A A A A A = small or no effect B = minor or moderate effect C = severe effect The material resistance is influenced by temperature and concentration of the medium. The data has to be seen as indication and does not guarantee the material properties. Printed in Germany. Art.-Nr.: 17182 5/28 Gardner Denver Thomas GmbH Siemensstraße 4 Gewerbegebiet Nord D-82178 Puchheim Phone: +49 89 89- Fax: +49 89 88368 e-mail: thomas.de@gardnerdenver.com http://www.gd-thomas.com