Performance evaluation of a small-scale polygeneration plant including a desiccant cooling system and an innovative natural gas ICE

Similar documents
HIGH EFFICIENCY POLYGENERATION APPLICATIONS (HEGEL) I,II

Experimental assessment of a small-scale trigeneration plant with a natural gas microturbine and a liquid desiccant system

Perspectives and evolution of reciprocating cogeneration systems. Pasquale Campanile

POLYGENERATION: TECHNOLOGIES & POSSIBILITIES. Prof.Emeritus S.Srinivasa Murthy Refrigeration & Clean Energy Technologies

Combined Heat and Power

Combined Heat & Power An Overview

Cogeneration. Thermal Chillers. and. .. ASHRAE National Capital Chapter. Arlington, VA 10/10/2012

A CHCP System Constituted by Microturbine and Exhaust Absorption Chiller

3 Mechanical System Redesign

The Present and Future of Refrigeration, Power Generation and Energy Storage. R.Z. Wang Shanghai Jiao Tong University

ago congelo When hot turns to cold

December 13, 2012 Energy Efficient Cooling Information Service Webinar Series Christine Brinker and Gearoid Foley CHP with Absorption Chilling

Investigation of the Performance of Trigeneration and CO 2 Refrigeration Systems in Supermarket Applications

Project Proposal Proposal for Investigation of Alternative Systems

ENERGY CONSERVATION STRATEGIES FOR HVAC SYSTEMS

Implementation of energy efficiency programs using cogeneration based on internal combustion engines

Rank. Rank Technology.

The 34 th Congress of Euroheat & Power

ORGANIC RANKINE CYCLE TECHNOLOGY PRODUCTS AND APPLICATIONS APRIL 2013 EAR 99 - NLR

Innovative Systems for Solar Air Conditioning of Buildings

DESIGN SUSTAINABLE BUILDING WITH OPTIMIZED COMBINED HEATING, COOLING, AND POWER (CHCP) SYSTEM

A Cooling, Heating, and Power for Buildings (CHP-B) Instructional Module

BUILDINGS & OFFICE SPACES INDUSTRIAL SOLUTIONS. Combined production of Heat and Power. Waste Heat Recovery Bottoming Cycle

CHP 201: Commercial & Critical Facilities

Combined Heat and Power (CHP)

Overview of cogeneration technology and application

Heat Recovery. Integrated CHP Systems Corp.

Available online at ScienceDirect. Energy Procedia 75 (2015 )

Learning objectives and outcomes

Energy Audit Summary Report Audit No. 21. Pharmaceutical Industry

Cogeneration in a Hospital: a case Study

Research on Heat Conversion Systems for Power and Refrigeration

JMS620 Natural Gas 3MW Tri-generation System

Efficiency Maine Symposium Combined Heat & Power Portland, ME. Dan Kelley-Vice President. & Service Line Leader Portland, ME

Combined Cooling, Heating and Power (CCHP) in Distributed Generation (DG)

A Study on the Integration of a Novel Absorption Chiller into a Microscale Combined Cooling, Heating, and Power (Micro-CCHP) System

Application of Advanced Energy Technologies

Termotecnica Pompe di Industriale. Gli atti dei convegni e più di contenuti su

ADVANCED ABSORPTION CHILLER CONVERTS TURBINE EXHAUST TO AIR CONDITIONING

Report on thermal cooling system implementation and performance

Gas Turbine Inlet Air Cooling System

Combined Heat and Power *

CHP and the Industrial Sector (Recycling Energy)

Workshop Industrial application of SOFC systems: the DEMOSOFC project

Eurammon Symposium Ammonia Absorption Refrigeration. Colibri b.v.

Waste Heat Recovery at Compressor Stations

Optimization of a Cogeneration System in the Automotive Industry

US1 IEA. Renovation of Wausau West High School, Wisconsin, United States of America

CEE NATIONAL MARKET TRANSFORMATION COMBINED HEAT & POWER. Gearoid Foley, Sr. Advisor DOE s Mid-Atlantic CHP TAP April 1, 2014

ST-4 Polygeneration plant. Parc de l Alba Cerdanyola del Vallès

Climate Change is the biggest challenge of today Mankind. Until now, there is not an easy solution

Simulation And Optimization of a Solar Absorption Cooling System Using Evacuated Tube Collectors

Energy Recovery Process Cooling Example. Presentation - Overview. Air Change Australia Pty Ltd. Air Change Energy Recovery Range

8Combined Cooling, Heating and Power Technologies (CHP): An Overview

Enhanced Efficiency, Sustainable Power Generation, and CO2 Emission Reduction through Organic Rankine Cycle Technology

Low temperature cogeneration using waste heat from research reactor as a source for heat pump

wb Thermodynamics 2 Lecture 11 Energy Conversion Systems

Evaluation of Distributed Generation Technologies in Luxury Hotels Marco Gambini, Michela Vellini

Fresh air pre-cooling and energy recovery by using indirect evaporative cooling in hot and humid region a case study in Hong Kong

THESIS PROPOSAL UNIVERSITY RIDGE AT EAST STROUDSBURG UNIVERSITY EAST STROUDSBURG, PA PREPARED FOR: JAMES FREIHAUT, PH.D.

TransPacific Energy Advantage: Case Studies

Microturbine Energy Solutions in the CHP Industry

Trigeneration using Absorption Chiller Technology

Waste Heat Recapture from Supermarket Refrigeration Systems

ImprovIng energy efficiency with chp: how to evaluate potential cost savings

2. TECHNICAL DESCRIPTION OF THE PROJECT

Influence of the control strategy on the heat rejection potential and electricity consumption of air-to-water condensers for solar cooling systems

COMBINED HEAT AND POWER (CHP) MARKET MARKET SIZE, SEGMENTATION, REGULATIONS AND KEY COUNTRY ANALYSIS TO 2025

RESEARCH ON MICRO GAS TURBINE EXHAUST HEAT RECOVERY AND USAGE

A TEST FACILITY FOR DISTRIBUTED COGENERATION: EXPERIENCES ON A MICROTURBINE AND CHILLER BASED PLANT

Ing. Alberto Cavallo, Ing. Ezio Pasqualon

INNOVATIONS IN VENTILATION TECHNOLOGY 21ST ANNUAL INTERNATIONAL AIVC CONFERENCE THE HAGUE, NETHERLANDS, SEPTEMBER 2000

CHP The Concept. An Introduction to Combined Heat and Power CHP The Trustees of the University of Illinois

FMI ENERGY CONFERENCE. Orlando September 2008

Integrated Production of Power Cooling and Water Jürgen Scharfe

Thermally operated mobile air-conditioning system

ashrae) VENTILATING PRINCIPLES AIR CONDITIONING OF HEATING AND 7th Edition A Textbook with Design Data Based on the 2013 ASHRAE Handbook Fundamentals

TRIGENERATION FOR BUILDINGS European Seminar by COGEN Europe. Market opportunities in South Europe

Enhancing Energy Efficiency in Dairies. Mr. Anshuman Pandey, Lead Application Engineer OPRA Turbines International B.V

Heat recovery from industrial installations

Heat recovery from diesel engines and gas turbines

Syllabus Cogeneration: Definition, Need, Application, Advantages, Classification, Saving potentials

Heat recovery from diesel engines and gas turbines

A Study Regarding the Performances of Trigeneration Systems

ENERGY AND ECONOMIC ANALYSIS OF AN AUDITORIUM S AIR CONDITIONING SYSTEM WITH HEAT RECOVERY IN VARIOUS CLIMATIC ZONES

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Organic Rankine Cycle System for Waste Heat Recovery from Twin Cylinder Diesel Engine Exhaust

Performance Evaluation Of Gas Turbine By Reducing The Inlet Air Temperature

Industrial Thermal Utilities

Engineering Thermodynamics

PECO CHP Symposium Mid Atlantic CHP Technical Assistance Partnership CHP Overview September 20, 2018

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

Customized Absorption Heat Pumps for Utilization of Low-Grade Heat Sources

AIRAH - BUILDING ENERGY PRECINCTS

OPTIPOLYGEN. TRAINING MATERIAL in POLYGENERATION in the FOOD INDUSTRY. WP5 Derivable Work Package Leader: Instituto Superior Técnico

BEYOND COMBINED HEAT AND POWER: POLIGENERATIVE SMALL SCALE RENEWABLE PLANT

SOME ENERGY-EFFICIENT TECHNOLOGIES IN JAPAN

24th World Gas Conference ARGENTINA WOC 5.1: Industrial Utilisation CHP - Sharing on Gas District Cooling (GDC) in Malaysia

Heat pumps. Oilon ChillHeat. Optimized cooling and heating performance

POLYCITY- WORKSHOP BASEL SUSTAINABLE TOWN PLANNING AND ENERGY BENCHMARKING OF BUILDINGS

Transcription:

Performance evaluation of a small-scale polygeneration plant including a desiccant cooling system and an innovative natural gas ICE Armando Portoraro Energetics Department Politecnico di Torino (Italy) 1

Armando Portoraro Armando Portoraro is graduated at Politecnico di Torino in Aerospace Engineering in 2002. He worked as a fellow tenure at CRF from September 2001 till May 2002. After a consultancy experience of 4 years in KPMG, an international firm of business advisory services, he is presently fellow researcher in the Energetics Department at Politecnico di Torino in the field of design and construction of microgeneration system for civil and industrial infrastructures. 2

Politecnico di Torino Dipartimento di Energetica Performance evaluation of a small-scale poly-generation plant including a desiccant cooling system and an innovative natural gas ICE Torino, 25 th of May 2007

Combined Heat, Cooling and Power: the concept Combined Heat, Cooling and Power applications Integrated System Located at or near a building facility Provide a portion of the electrical load Utilization of the Thermal Energy: Heating Cooling Dehumidification Process heat System designation Size range Applications Mega Large Mid Small-scale 50 100+ MWel 10 s of MWel 100 s kwel several MWel <100 s kwel Very Large Industrial Plants Usually Multiple Smaller Units Custom Engineered Systems Industrial & Large Commercial Plants Usually Multiple Smaller Units Custom Engineered Systems Commercial & Light Industrial Plants Single to Multiple Units Potential Packaged Units Small Commercial & Residential Appliance Like 4

Typical small and medium scale trigeneration system functional layout Cogeneration and trigeneration allow a fuel economy of 15 30 % (with respect to separate production) 5

Small-scale CHCP technologies Electric generation equipment Reciprocating engines Microturbines Heat recovery Hot water steam Thermally Activated Technologies (TAT) Absorption Chillers Desiccant dehumidification 6

Reciprocating engines Fastest selling, least expensive and most commonly used CHP prime movers Heat usually recovered as hot water at 85-90 C or low pressure steam (100-120 C) Electrical efficiency range: 30% - 35% Type of engines: Spark ignited: natural gas compression ignition: diesel Good part load operation 7

Microturbines Small turbines with recuperation Capacity range: 25 kw to 400 kw Electrical Efficiency Range: 25% to 30% Thermal (Recoverable) Energy: exhaust gases Advantages: Compact Size Low Emissions Fuel Flexibility Modular Lower Maintenance Quicker Start Disadvantages: Moderate Conversion Efficiencies Poor Part Load Operation Requires High Pressure Gas or Gas Compressor 8

Thermally Activated Technologies Absorption Chillers Liquid Desiccant Direct Combustion or Waste Heat Fired Water as the Refrigerant and Lithium Bromide as the absorbent Ammonia as the refrigerant and water as the absorbent Remove bacteria, pollutants and viruses Operates with low reactivation temperatures Can connect many process air sections with a single regeneration section Humidity control - vary solution concentration ; temperature control - vary solution temperature 9

The liquid desiccant cooling system Air dehumidification is obtained through the sorption of the humidity by a LiCl-water solution This capacity to absorb moisture is due to the difference between the water vapour pressure at desiccant surface and that of the surrounding air: when the vapour pressure at the desiccant surface is lower than that of the air, the desiccant attracts moisture. Vice versa, the desiccant releases moisture (regeneration process) The liquid desiccant system operates in three phases: 1. conditioning phase: air is dehumidified through air contact with the LiCl-water solution in a porous matrix; humidity sorption always generates an amount of sensible heat equal to the latent heat of the water vapour taken up by the desiccant, so that the desiccant is warmed 2. regeneration phase: hot water from the heat recovery unit of the ICE heats the desiccant solution so that its water vapour pressure becomes higher than that of the outside air. Outside air is passed through the desiccant, and water evaporates into the air from the desiccant solution, thus concentrating the solution 3. desiccant cooling phase: all the thermal energy acquired by the desiccant substance during the conditioning and the regeneration phases must be dissipated, so that a cooling tower is needed 10

The ICE-D application The application falls within HEGEL, the acronym of an R&D project funded in the EU 6th Framework Program, whose objective is to develop, demonstrate and compare high efficiency applications of micro-trigeneration for the civil and industrial sectors The ICE-D application consist of a natural gas ICE coupled to a liquid desiccant (LiClwater) cooling system From some preliminary researches conducted on this topic it seems that this system architecture has not yet been thoroughly investigated. For this reason a similar trigeneration plant was included in the investigation objectives of the 6 th European Framework Program and is going to be installed and tested at the Politecnico di Torino Internal Combustion Engine Cogenerator The ICE-D application Liquid desiccant cooling system 11

The plant layout The concept layout of the system consist of: one CRF ICE cogenerator unit (capacity of 120kWel, 195 kwt) a liquid desiccant system operating on fresh air (nominal capacity of 20.000 m 3 /h) one open cooling tower to provide cold water to the desiccant conditioner one rotary heat exchanger (supply/return air) two 20.000 m 3 /h adiabatic humidifiers, operating on the supply and return air Exhaust air Exhaust fan D E Regenerator Exhaust air 90 C 80 C F C High temperature heat exchanger Exhaust gases ICE cooling water Low temperature heat exchanger electrical power B Power electronic unit Battery Natural gas A To grid / user G 25 C 50% Building Air-filter O Humidifier R 19 C 90% N Rotary Heat Exchanger 25 C 60% S M T Regenerator Conditioner I L Regenerator fan Air-filter Outdoor air 20.000 m 3 /h 28,8 C 68% H 18 C 66% 21 C 48% Humidifier 27,6 C 32% Q Supply fan Air-filter Outdoor air 20.000 m 3 /h 28,8 C 68% Cooling tower 24 C P 12

The ICE cogenerator The cogenerator (120 kwel, 195 kwt) was developed and set up by FIAT Centre of Research in Turin, Italy The heat is recovered from the ICE cooling water and from the exhaust gases, through two heat exchangers and a secondary hot water loop The innovations of the system concern both the technology and the provided services: high part load efficiency low pollutant emissions (lower than an equivalent boiler) built-in UPS system, which assures power continuity without the need of external devices high efficiency and high flexibility, even during stand-alone applications (i.e. not connected to any external grid) 13

The ICE cogenerator (2) The power electronic unit, made up of an AC/DC-DC/AC converter, allows the engine to operate at variable speed, while delivering 50 Hz AC to the grid ηel/ηel,max 1.2 1 0.8 0.6 variable speed 0.4 costant speed 0.2 0 0 0.2 0.4 0.6 0.8 1 Pel/Pel,max ICE UPS System Command, protection and measure Utilities The power electronics unit allows the engine to operate at part load conditions by varying the rotating speed; this strategy allows the engine to achieve higher part load efficiency than conventional cogenerators CHP unit technical features Engine type Otto 4T Displacement ~6 litres Emission reduction TWC Dry weight 4000 kg Fuel Natural Gas Generator Asynchronous water-cooled Power electronics AC/DC - DC/AC converter Container dimensions (L/W/H) 3800 / 1200 / 1900 mm Electric power 120 kw Thermal power 195 kw Electrical efficiency 32% Energy utilization factor 84% 14

The liquid desiccant cooling system Principle and functional representation of a liquid desiccant cooling system Characteristics of the desiccant cooling system Number of units 4 Typical air capacity (conditioner) 5000 m 3 /h Typical air capacity (regenerator) 5000 m 3 /h Typical Latent cooling capacity ~ 40 kw Desiccant solution type LiCl-water Desiccant solution max concentration 55% Desiccant solution capacity 125 lt Typical Moisture extraction ~ 50 lt/h Auxiliary power 4.8 kw el Net weight 540 kg Operating weight (including LiCl) 690 kg Dimensions (L/W/H) (mm) 2240/1420/1575 15

The plant layout The ICE-D application at the Politecnico di Torino has been conceived to supply airconditioning to a building dedicated to educational activities (several classrooms) The building is currently heated in winter through an all-air system integrated with hot water heaters (heat, both for AHU and heaters, is provided by a connection to district heating). No cooling is present in summer 16

System performance In order to evaluate system performance, ASHRAE climate conditions for Turin has been considered as outdoor temperature and relative humidity conditions. The set point condition inside the building are the typical one for summer season Indoor set point conditions Design wet bulb temperature T db = 25 C T wb = 18 C R.H. = 50% T db = 28.8 C T wb = 24.2 C R.H. = 68% X=17.2 g v /kg a D C High temperature heat exchanger Exhaust gases B E ICE cooling water Natural gas A first preliminary assessment of the performances of the system has been made for the nominal operating condition, considering values of temperature and R.H. in different points of the plant supplied by the designer 25 C 50% Building R 19 C 90% Air-filter Humidifier O N 18 C 66% 21 C 48% Humidifier Regenerator Exhaust air Exhaust air F 90 C 80 C Exhaust fan 25 C 60% Regenerator Rotary S T Heat Exchanger M Conditioner 27,6 C 32% Q Low temperature heat exchanger electrical power I Regenerator fan L Supply fan A Power To grid / user electronic unit G Battery Outdoor air Air-filter 20.000 m 3 /h 28,8 C 68% H Outdoor air Air-filter 20.000 m 3 /h 28,8 C 68% Cooling tower 24 C P 17

System performance (2) Ventilation required by the building 20.000 m 3 /h Power introduced into the internal combustion engine by the natural gas Pfuel = 375 kw Thermal power provided by the CHP system Qth = 195 kwt Cooling power supplied by the conditioner Qc = 168 kwc Total cooling power supplied to the building (desiccant + rotary heat exchanger) Qc,p = 215 kwc Electrical power produced by the CHP unit Pel = 120 kwe. Pnet = 76 kwe CHCP plant efficiency (Pnet + Qc,p) / Pfuel = 0.78 60 kw t net losses76 input fuel 375 kw el electrical 120 kw el kwel power CHP 195 kwt cooling 168 kw c tower power liquid desiccant building 215 kw c + rotary exhausted exch. 242 kw t thermal power cooling power supplied to the building 18

System innovation The innovation of the application can be considered at four levels: 1 Reciprocating cogenerator The plant will be connected to a local grid that is not only able to satisfy the requirements of the connected local users, but is also available for experimental activities and transient load simulations 4 Electrical connections The CHP unit, has the distinct feature of showing a very high efficiency above all at part load conditions ICE-D Desiccant cooling system Thermally Activated air Conditioner (TAC) system with a liquid desiccant solution is applied. The task of the TAC is to remove humidity from the air without the aid of any additional mechanical cooling system 2 Regeneration heat is recovered from the CRF CHP unit, which among its distinctive characteristics is capable of operating in dual mode function (in parallel to the grid or in standalone UPS mode) Particular architecture of the system 3 19

Road map Ongoing activities Refining of sizing and performance assessment Ducting and integration of Desiccant units with cogenerator. The cogenerator will be installed in a separate building, a direct hot water connection with the desiccant units is foreseen. Also current air ducting will be modified to exploit the existing AHU and allow for integration of cooling sub-systems. To do activities Design and setup of system controls Installation of the system (foreseen within summer 2007) Design and setup of the measurement system and the data acquisition devices Emissions evaluation Air Quality assessment Operation and Maintenance costs evaluation Extensive performance analysis and experimental tests (steady state and transient) 20

Acknowledgement The support provided for this work under EU Sixth Framework Program Priority 6.1 (contract TREN/05/FP6EN/S07.56687/020153, HEGEL Project, High Efficiency polygeneration applications) is gratefully acknowledged 21

Corresponding Author Politecnico di Torino Dipartimento di Energetica Corso Duca degli Abruzzi, 24-10129 Torino Dr. Armando Portoraro Energy and Environment Systems Tel. +39 011 564 4485 Fax. +39 011 564 4599 E-mail armando.portoraro@polito.it HEGEL Contract n 20153 High Efficient polygeneration applications 6th Framework Program - Priority 6.1 22