Environment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra

Similar documents
Environment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand

SIX MONTHLY REPORT OF EMP CLEARANCE J11015/536/2008- IA-II(M) FOR THE PERIOD OCTOBER-2014 TO MARCH-2015 (1 ST June 2015)

Discipline Chemical Testing Issue Date Certificate Number T-3790 Valid Until Last Amended on - Page 1 of 5

ENVIPRO Laboratories, 2nd Floor, Sy. No. 63/4, Site No. 5, P&T Layout Road, Ashwath Nagar, Srigandhada Kaval, Sunkadakatte, Bangalore, Karnataka

Discipline Chemical Testing Issue Date Certificate Number T-3617 Valid Until Last Amended on

KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana

Deep Testing Laboratories, Plot No.- 338, Sector-58, Ballabhgarh, Faridabad, Haryana. Discipline Chemical Testing Issue Date

Madhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh

Winmet Technologies Private Limited, Plot No. E-65, Site-IV, UPSIDC, Greater Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date

Prakruti Environmental Engineers (Environmental Laboratory), 1, Utkanth Society, B/H Alkapuri Club, Alkapuri, Vadodara, Gujarat

ENVIRONMENTAL CLEARANCE (J-11015/121/ IA.II(M) ) October 14 to March 15. INTEGRATED ASHOK WASHERY cum FBC

Nichrome Testing Laboratory and Research Private Limited, No nd Main, German Hospital Road, Narayanpur, Dharwad, Karnataka

Superintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal

Discipline Chemical Testing Issue Date Certificate Number T-3553 Valid Until Last Amended on - Page 1 of 9

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed

Haryana Test House & Consultancy Services, 50-C, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date

Nexus Test Labs Pvt. Ltd., No. 29, 2 nd Floor, 3 rd Cross, Singaiahnapalya, Mahadevapura, Bangalore, Karnataka

MECON LIMITED RANCHI , INDIA

Annex 7.1 National Ambient Air Quality Standards for Nepal, 2003

SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS

MECON LIMITED RANCHI , INDIA

Jordan Water Company/ Miyahuna. Quality, Laboratories and Water Safety Department. Service Price List

A. SPECIFIC CONITIONS:- SL NO. Peak production from Jarangdih OCP is not exceeding 0.88 MTPA

Jordan Water Company/ Miyahuna. Quality, Laboratories and Water Safety Department. Service Price List

QUALITY ASSESSMENT of WATER and WASTEWATER

Jordan Water Company/ Miyahuna. Quality, Laboratories and Water Safety Department. Service Price List. No. Test Test Method

GLOBAL TECH. ENVIRO EXPERTS PVT. LTD. (FORMERLY GLOBAL EXPERTS) An ISO-9001:2008 Certified Company

Jordan Water Company/ Miyahuna Production and Quality Directorate Quality Control and Assurance Department Service Price List

2. GUIDELINES FOR THE EVALUATION OF DRINKING-WATER QUALITY FOR HUMAN CONSUMPTION WITH REGARD TO CHEMICAL, PHYSICAL AND BACTERIOLOGICAL QUALITY

2019 Microbac Laboratories Inc. Ohio Valley Division

ANALYTES available for testing

DRINKING WATER ANALYSIS SUMMARY

French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road

SPECIFICATION NO.1197S Addendum No.4 Attachment D. Appendix L- Ground Water Quality Data and Revised Construction Groundwater Discharge Plan

Mahabal Enviro Engineers Pvt. Ltd. Pollution monitoring, Engineers & Contractors in Environmental Management

Durban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July June 2014

Appendix I. Agreement on National Environmental Standards of Lao PDR, 2009

Final Report WP-225. WatR Pollution Study. Open Date: 10/18/13. Close Date: 12/02/13. Report Issued Date: 12/04/13

Appendix U. Mapping of Water Quality Concentration Contours across the Province

Parameter monitored Standard methodology used Detection limit

ENVIRONMENTAL LABORATORY

Laboratory & Field Instruments: Sample Cells. Sample Cells. See Inside!

CALA Directory of Laboratories

QUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;

A. Water sampling and analysis

GOVERNMENT OF ZAMBIA. The Environmental Protection and Pollution Control Act, 1990 (No. 12 of 1990)

CALA Directory of Laboratories

Appendix C1: Batch Kinetics Tests

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CALA Directory of Laboratories

Annex 2: National Environmental Quality Standards (Extract from the Gazette of Pakistan applicable to STZ CETP)

W12A Landfill Groundwater, Leachate, Water Well, Landfill Gas and Surface Water Quality Monitoring Program

CALA Directory of Laboratories

CATEGORY 1 & 2 TRADE WASTE QUALITY LIMITS. The temperature shall not exceed 28 degrees Celsius.

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

Environmental Protection Agency

CALIFORNIA STATE ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing

Indian Standard DRINKING WATER SPECIFICATION (Second Revision)

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

CALA Directory of Laboratories

West Virginia Department of Environmental Protection hereby certifies Microbac - Ohio Valley Division

Environmental Management System

Panasonic India Pvt. Ltd.

APPENDIX I. LAMPIRAN I - RKL DAN RPL KEGIATAN TERPADU PROYEK PENGEMBANGAN TANGGUH LNG i

Final Report DMR-QA 36. NPDES Permit: IL DMR-QA Study. Open Date: 03/18/16. Close Date: 07/01/16. Report Issued Date: 07/29/16

Consolidated TEXT CONSLEG: 1979L /06/2003. produced by the CONSLEG system. of the Office for Official Publications of the European Communities

QCVN 40:2011/BTNMT NATIONAL TECHNICAL REGULATION ON INDUSTRIAL WASTEWATER

Central Institute of Fisheries Technology, Matsyapuri P.O., Willingdon Island, Cochin, Kerala. Discipline Chemical Testing Issue Date

Notification of Ministry of Industry. Industrial Effluent Standards B.E. 2560

having examined Legislative Decree No.21 of 1996 with respect to the and Ministerial Order No.10 of 1999 with respect to the Environmental

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE

Water and Waste Water Management in Yangon, Myanmar

Specifies test methods that cover the determination of chloride ion in water, wastewater and brines.

Submitted by: M/s Panasonic India Ltd

Atmy Analytical Labs Pvt. Ltd., I-38, DLF Industrial Area, Phase-1, Faridabad, Haryana. Discipline Chemical Testing Issue Date

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

DROGHEDA LANDFILL SITE COLLON ROAD, MELL, DROGHEDA

Acceptance standards and charging rates for

Schedule. This laboratory has demonstrated its technical competence to operate in accordance with MS ISO/IEC 17025:2005 (ISO/IEC 17025:2005).

Tolerance and Classification

OFFICE OF LICENSING & GUIDANCE

REVISED NATIONAL ENVIRONMENTAL QUALITY STANDARDS (NEQS)

REGULATIONS FOR WASTEWATER RE-USE AND DISCHARGE

Thermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries

Report Transmission Cover Page

In the fall of 2008, Barr and PolyMet identified four sources of historical Colby Lake water quality data. Those sources are listed below:

Abu Dhabi Trade Effluent Standards & Regulations Summary

ENVIRONMENTAL LEGISLATION AND REGULATION IN MALAYSIA

Micro Methods Laboratory Quality Assurance Manual

Schedule of Accreditation

THE WATER POLLUTION CONTROL REGULATIONS, 1999

Schedule. Type of Test/ Properties Measured/ Range of Measurement. Biochemical Oxygen Demand (BOD) Calcium as Ca. Chromium, Hexavalent

DR 1900 PORTABLE SPECTROPHOTOMETER

Independent Analytical Supplies Ltd (Trading as) IAS Laboratories

CE 370. Wastewater Characteristics. Quality. Wastewater Quality. The degree of treatment depends on: Impurities come from:

Chapter 1 (BFC32403) and Standards

DelAgua Safe Water. Reagent Identification Chart for Lovibond Tintometer photometers

Chemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits

EPA USGS I EPA SM 4500-NH 3 B [18 th, 19 th, 20 th ] AOAC SM 4500 NH 3 C [19 th, 20 th ] SM 4500 NH 3 E [18 th ]

Hitech Healthcare Laboratory and Research Centre, 201, Sahaj Arcade, Science City Road, Ahmedabad, Gujarat

Transcription:

Last Amended on - Page 1 of 9 I. POLLUTION & ENVIRONMENT 1 Effluent / Waste Water (As per EPA 2000) Ammonical Nitrogen / Free Ammonia IS 3025(Part 34):1988, RA 2009, Nessler s Method 0.02-2.5 mg/l, B.O.D (3 days 27 o C) IS 3025 (Part 44): 1993, RA 2003 3 day incubation at 27 C 2.00-100.00 mg/l, Cadmium COD AAS-GTA Method, 3111B Closed Reflux, Titrimetric Method, 5220C 0.5-15.00 µg/l, 4.0-800.0 mg/l Chromium IS 3025 (Part 52) : 2003 AAS-Flame Copper IS 3025 (Part 42) : 1992 RA 2009, AAS-Flame 0.06-15.0 mg/l, 0.03-10.0 mg/l Dissolved Phosphate as PO4-3, 4500C Molybdovanadate Method, 4500C 0.3-45.0 mg/l Iron IS 3025 (Part 53) : 2003, RA 2009, 0.06-15.0 mg/l

Last Amended on - Page 2 of 9 Fluoride SPANDS Method, 4500F, D Hexavalent Chromium 1,5-Diphenylcarbohydrazide Method, 3500C 0.01-0.7 mg/l Manganese IS 3025 (Part 59) : 2006, Nickel IS 3025 (Part 54) : 2003, 0.02-5.0 mg/l 0.1-20.0 mg/l Nitrate Nitrogen UV-Spectrphotometric Method, 4500B 0.5-45.0 mg/l Oil & Grease IS 3025(Part 39):1991, RA 2003, Partition Gravimetric Method 2.0-1000.0 mg/l Lead AAS-GTA Method 3113B 5.0-100.0 µg/l ph value IS 3025 (Part 11):1983, RA 1996, Electrometric Method 0.2-13.9

Last Amended on - Page 3 of 9 Phenolic Compounds 4-Amino antipyrine Method, 5530C 0.002-0.25 mg/l Sulphide Methylene Blue Method, 4500D 0.005-0.9 mg/l Temperature IS 3025 (Part 9):1984, RA 2002, Thermometeric Method 0.5-100.0 o C Total Kjeldahl Nitrogen Total Residual Chlorine Kjeldahl Method, 4500C DPD Method, 4500G 1.0-150.0 mg/l Total Suspended Solids IS 3025 (Part 17):1984, RA 1996, Gravimetric Method Zinc IS 3025 ( Part 49 ) : 1994, RA 2009, Color IS 3025 (Part 4): 1983 Platinum Cobalt Method 10.0-5000.0 mg/l 0.01-10 mg/l 5.00-500.0 Hazen

Last Amended on - Page 4 of 9 II. WATER 1. SURFACE WATER Dissolved Oxygen IS 3025 (Part 38):1989, Winkler Azide Method Odour IS 3025 (Part 5):1983, Physical (Qualitative) Turbidity IS 3025 (Part 10):1984, Nephelometric Method B.O.D (3 days 27 o C) IS 3025 (Part 44): 1993, RA 2003, 3 day incubation at 27 C 0.1-20.0 mg/l Qualitative 1.0-100.0 NTU 2.00-100.00 mg/l, Cadmium AAS-GTA Method,3113 0.5-15.00 µg/l, Chlorides IS 3025(Part 32):1988, RA 2007, Argentometric Method, 5530C Colour IS 3025 (Part 4): 1983 Platinum Cobalt Method Copper IS 3025 (Part 42) : 1992 RA 2009, Disolved Oxygen IS 3025 (Part 38):1989, RA 2003, Winkler Azide Method 2.0-1500.0 mg/l 4.5-500.0 Hazen unit 0.03-10.0 mg/l 0.1-20.0 mg/l

Last Amended on - Page 5 of 9 Iron IS 3025 (Part 53) : 2003, RA 2009, 0.06-15.0 mg/l Fluoride Hexavalent Chromium Nitrate Lead SPANDS Method, 4500D 1,5-Diphenylcarbohydrazide Method, 3500C UV-Spectrphotometric Method,4500B AAS-GTA Method, 3113B 0.01-0.7 mg/l 0.5-45.0 mg/l 5.0-100.0 µg/l ph value IS 3025 (Part 11):1983, RA 1996, Electrometric Method 0.2-13.9 Phenolics Sulphate 4-Amino antipyrine Method, 5530C Turbidity Method,4500E 0.002-0.25 mg/l 2.0-70.0 mg/l

Last Amended on - Page 6 of 9 2. DRINKING WATER Total Dissolved Solids IS 3025 (Part 16):1984 RA 2006, Gravimetric Method Total Suspended Solids IS 3025 (Part 17):1984, RA 1996, Gravimetric Method Zinc IS 3025 ( Part 49 ) : 1994, RA 2009, Alkalinity IS 3025(Part 23):1986, RA 2009, Titration Method 25.0-5000.0 mg/l 10.0-5000.0 mg/l 0.01-10 mg/l 4.0-2000.0 mg/l Boron Carmine Method,4500B 0.2-15.0 mg/l Calcium IS 3025 (Part 40): 1991, RA 2009, EDTA Method 1.6-800.0 mg/l Cadmium AAS-GTA Method, 3113B 0.5-15.0 µg/l, Chlorides IS 3025 (Part 32):1988, RA 2007, Argentometric Method 2.0-1500.0 mg/l

Last Amended on - Page 7 of 9 Colour IS 3025 (Part 4): 1983 Platinum Cobalt Method Copper IS 3025 (Part 42) : 1992 RA 2009, Iron IS 3025 (Part 53) : 2003, RA 2009, 4.5-500.0 Hazen unit 0.03-10.0 mg/l 0.06-15.0 mg/l Fluoride Hexavalent Chromium SPANDS Method, 4500D 1,5-Diphenylcarbohydrazide Method, 3500C 0.01-0.7 mg/l Manganese IS 3025 (Part 59) : 2006, 0.02-5.0 mg/l Nitrate UV-Spectrphotometric Method, 4500B 0.5-45.0 mg/l Odour IS 3025 (Part 5):1983, RA 2012 Qualitative

Last Amended on - Page 8 of 9 Lead AAS-GTA Method, 3113B 5.0-100.0 µg/l ph value IS 3025 (Part 11):1983, RA 1996, Electrometric Method 0.2-13.9 Sulphate Turbidity Method, 4500E 2.0-70.0 mg/l Total Dissolved Solids IS 3025 (Part 16):1984 RA 2006, Gravimetric Method Total Hardness (CaCo 3 ) IS 3025 (Part 21):2009, EDTA Method 25.0-5500.0 mg/l 4.0-2000.0 mg/l Total Residual Free chlorine DPD Method, 4500G Turbidity IS 3025 (Part 10):1984, RA 1996, Nephelometric Method Zinc IS 3025 ( Part 49 ) : 1994, RA 2009, Odour IS 3025 (Part 5):1983, RA 2012 1.0-100.0 NTU 0.01-10 mg/l Qualitative

Last Amended on - Page 9 of 9 III. AIR, GASES & ATMOSPHERE 1. AMBIENT AIR QUALITY PM 10 IS 5182 (Part -23):2006 3.5-1000 µg/m 3 SO 2 IS 5182 (Part-II) : 1969 West & Gaeke Method 10-1050 µg/m 3 NOx IS 5182 (Part VI) : 1975 Jacobs & Hochheiser 06-750 µg/m 3 -X-X-X-X-X-X-X-X-X-X-X-X-X-X-