WATER TREATMENT PLANT BASED ON REVERSE OSMOSIS TECHNOLOGY litres Per Hour

Similar documents
5000 LPH COMPLETE MINERAL WATER PLANT

Sea Water Reverse Osmosis Container. 1. Description:

Commercial Reverse Osmosis System

'HR' SERIES INDUSTRIAL HIGH REJECTION SYSTEMS

PROflex* 60 Hz reverse osmosis machines from 50 to 360 gpm (12-82 m 3 /hr) Water Technologies & Solutions fact sheet.

PROflex* 60 Hz Reverse Osmosis Machines from 50 to 360 gpm

Seawater Desalination Plant General Specification

Water supplied by Marafiq does not meet the process requirements.

Reverse Osmosis. Lecture 17

Nairobi Funeral Home and Forensics BOREHOLE BILLS OF QUANTITIES

REVERSE OSMOSIS WATER TREATMENT

--... _ 2-- I I J: 3 4 /

Reverse Osmosis Desalinators

Engineering & Equipment Division

Cleaning. DATA Monitoring

Water Treatment Technology

The Basics. Reverse Osmosis is a process that is used to remove. Front Side 1. Controller


Aqualife Products (Australia) Pty Ltd Steam Sterilisor Water System

FLOW REVERSAL DESALINATION TECHNOLOGY

Membrane Technique MF UF NF - RO

Specifications: MoBetta Pro Series Water Store Skid 2600/5200/7800

Commercial Reverse Osmosis Systems and Accessories

Plot No. 1-7/B, Laxmi Co-op Industrial Estate, Hatkanangale , Kolhapur Dist. TENDER NO D5

FILMTEC Membranes. Tech Manual Excerpts. Principle of Reverse Osmosis. Figure 1: Overview of Osmosis / Reverse Osmosis

1500G-3000G USER'S MANUAL. Trouble shooting

Reverse Osmosis. Background to Market and Technology

PURE-PRO REVERSE OSMOSIS SYSTEM

Construction of new small scale desalination Units for education sector in the Gaza Strip

Water Purification & Reverse Osmosis

Never underestimate your fresh water needs

Ultra Watech Systems.

HYUNDAI MIRO-3A. Address: , Gongreung-Dong, Nowon-Ku, Seoul, Korea Tel) Fax) Homepage:

AXEON Tap Water Reverse Osmosis Systems... SECTION 1. FLEXEON Tap Water Reverse Osmosis Systems... SECTION 2

CONTENTS. reverse osmosis _02. the R.O. plant _04. Micro series _06. LE/HR series _08. series from 500 to 1250 l/h _10

RO102 P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address RO102

SERIES L ,000 GPD RO SYSTEMS

REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL. R12-Wall Mount

U-Version. Incoming City Water

Sea Water & Brackish Water Reverse Osmosis System

DRINKING WATER CONDITIONERS WATER PURIFIERS U.V. STERILIZERS REVERSE OSMOSIS GELPUR FILTER 113 GELPUR FILTER SI 113 GELPUR SL

PRODUCTS & APPLICATIONS COURSE WATER TREATMENT PRESENTATION John Waema

DemandPure Commercial EDI Systems

Commercial. Softeners Filters Reverse Osmosis


ElectroChemTM Advanced EDR

PRESENTATION OF DESALINATION VIA REVERSE OSMOSIS

EMERGENCY WATER. Immediate delivery when emergency response for water and/or waste water is required

Mission Statement. Profile and History. R.O. UltraTec s Advantages

Advanced water purifier system operation manual and setup guide

KTDA SEMINAR WATER TREATMENT PRESENTATION. John Waema

Well Water Quality Update and Next Steps. Public Works Commission Meeting April 17,

PSP Series Water Purification Systems

COMMERCIAL / INDUSTRIAL COOLING TOWER SIDE STREAM FILTER SYSTEMS

Some Standard Membranes: Filmtec Membrane, Hydronatics Membrane, Torry membrane and Koch Membrane.

HIGH COURT OF KARNATAKA, BENGALURU, DATED : 3 rd SEPTEMBER, TENDER NOTIFICATION

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

There will be a technical and financial evaluation. Technical evaluation will be 70% and 30% for financial.

Industrial & Municipal Catalogue

NIPPON PAPER RO SYSTEM + 2 Others

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

NANO FILTERING SYSTEM

Understanding Reverse Osmosis Mark Rowzee Mark Rowzee

COMMERCIAL REVERSE OSMOSIS. Installation Considerations. Model C350

AstroBoy Quick install guide

SPIRIT. Water purifier. Complete User Manual

Technical Presentation RO Basics. MWQA October Bill Loyd Technical Services & Development Dow Water & Process Solutions

FOR THOSE WHO WANT TO STAY AHEAD IN ENVIRONMENTAL and quality issues. desalination

Tender Notice. Description of work: Setting up Reverse Osmosis(RO) Plant for Model Village Adoption Project at Rajamayong Village, Morigaon, Assam.

Residential R.O. components

A Brief about Reverse Osmosis & Ultrafiltration!!

.1 All equipment, controls and accessories to be compatible with system design, and matched to the steam boiler(s) by the boiler Manufacturer.

Overview. Commercial High-Purity Water Systems and Applications. Quality Water Is Our Business

LABORATORY & DEIONIZED WATER SYSTEMS DESIGN AND CONSTRUCTION STANDARD

CHAPTER 2 COLD WATER SUPPLY. Prof. Dr. Uğur Atikol

Reverse Osmosis Water Purifying System DIRO

Membrane Technology: From Manufacture to. May Production

ERS-106UV USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

BSDI SERIES PACKAGED FILTRATION & DEIONISATION SYSTEMS FOR HIGH PURITY WATER PRODUCTION FOR GENERAL INDUSTRY

Jai Ambe Maa Aqua Tech

PRODUCTS CATALOGUE. Solar powered desalination and water purification

ADDITIONAL DETAILS OF THE PROJECT

Introduction of HR-800(M) Components. Cartridge filters. Installation diagram. Change membrane. Change filters. Operation regulation FAQ

Product Description / Equipment Specifications FlowMAX Reverse Osmosis Products FM Horizontal Pump Series

Reverse Osmosis, Nano Filtration and Ultra Filtration

FILMTEC Membranes How FILMTEC Seawater Membranes Can Meet Your Need for High-Pressure Desalination Applications

SRO-1000 SRO-2000 SRO-4000 INSTALLATION MANUAL US 33 N. Churubusco, IN Ph. (260) Fax (260)

OPERATION AND MAINTENANCE MANUAL UF-6-HF ULTRAFILTRATION SYSTEM

You get more for less at FSHS!

FS-8000 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product FS Date of purchase. Address

We are a leader in renewable energy powered water treatment systems.

Design Parameters Affecting Performance

Journal of Chemical and Pharmaceutical Research, 2014, 6(10): Research Article

SRO-300 INSTALLATION MANUAL

POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation

Industrial / Municipal

PURE WATER. Installation, Operation and Maintenance Manual. Wall Mounted Commercial Reverse Osmosis Systems. Series PWR2511. Table Of Contents.

S800-Direct Flow USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

NOTES P: 888-H2O-LOGIC ( ) F:

Transcription:

WATER TREATMENT PLANT BASED ON REVERSE OSMOSIS TECHNOLOGY Capacity: 25000 litres Per Hour 1

TECHNICAL SPECIFICATIONS Flow Rate : Feed Water : 48000 LPH Treated Water : 25000 LPH 1 RAW WATER PUMP To feed the Dual Media Filter at pressure more than 2.0 bar, which is min. operating pressure for filter. a) MOC : CI b) Type : Horizontal Centrifugal c) Flow Rate : 30000 liters per hour d) Head : 35 m e) Power Required : 2.2 KW 2

f) Electrical : 440 V, Three phase, 50 hz g) Cycle : 2900 rpm h) Make : Kirloskar i) Quantity : 1 No. 2 DUAL MEDIA FILTER To remove the total suspended solids, dirt, iron and reduce silt density index which can foul the membranes Vessel : a) Make :PPF Fabricated b) Material of Construction : SS 304 c) Diameter : 1400 mm d) Height : 2400 mm e) Shell Thickness: 3mm f) Dish Thickness: 4 mm g) Testing Pressure : 10 kg/cm 2 h) Opening : Top & Bottom i) Quantity : 1 No. Valve : a) Make :Prahar / Initiative, India b) Material of Construction : Noryl c) Type : Multiport Single lever value d) Size : 2 inches e) Maximum Flow Rate : 14,000 LPH f) Working Pressure : 2-4 Bar g) Working : Down-Flow Media : Mixed bed sand media consisting of the following i) Gravel ii) Pebbles iii) Quartz Sand iv) Anthracite Average Porosity 50 micron particulate size 3

Bed depth : 1800 mm Pipelines & Accessories : Pipes and fittings in SS 304 3 ACTIVATED CARBON FILTER Vessel : To remove the total color, smell, odor, from the water. a) Make: PPF b) Material of Construction: SS 304 c) Diameter :1400 mm d) Height : 2400 mm e) Shell Thickness: 3mm f) Dish Thickness: 4 mm g) Testing Pressure : 10 kg/cm 2 h) Opening : Top & Bottom i) Quantity : 1 No. Valve : a) Make: Initiative b) Material of Construction : Noryl c) Type : Multiport Single lever value d) Size : 2 inches e) Maximum Flow Rate : 30,000 LPH f) Working Pressure : 2-4 Bar g) Working : Down-Flow Media : Mixed bed sand media consisting of the following i) Gravel ii) Pebbles iii) Carbon Average Porosity 50 micron particulate size Bed depth : 1800 mm 4

Pipelines & Accessories : Pipes and fittings in SS 304 4 DOSING SYSTEM 5 MICRON FILTER To dose antiscalant chemical to protect the scaling formation on RO membranes. a) MOC : PP b) Capacity : 5 LPH c) Pressure : 7 Bar d) Qty. : 1 No. e) Make :SEKO / Etatron DS,Italy To remove the fine particles up to 05 microns and reduce silt density index levels to acceptable level. Cartridge Filter & Housing Housing : a) Make: Pentair India b) MOC of Housing: PP c) Length : 20 d) Diameter: 4.5 e) Quantity : 2 no. Cartridge : f) Make : Filtermation,Malaysia g) Cartridge MOC : Polypropylene h) Length: 20 i) Diameter : 4.0 j) Quantity: 2 no. k) Micron rating : 05 micron 6 HIGH PRESSURE PUMP 2 nos 5

To feed the Reverse Osmosis Membrane at pressure more than the osmotic pressure taking into consideration flux rate, flow and recovery. a) MOC : Stainless Steel 304 b) Type : Vertical Multistage c) Flow Rate : 48000 liters per hour d) Head : 100 mwc e) Power Required : 11 KW f) Electrical : 440 V, three phase, 50 hz g) Cycle : 2900 rpm h) Make : Grundfos. 7 RO MEMBRANE To remove the major part of TDS up to 98% by Reverse Osmosis Membranes arranged and designed to give adequate flow and recovery. a) Type : Spiral Wounded b) Diameter of Membrane : 8.0 inch c) Length of Membranes : 1 Mt. d) No. of Membranes : 10 e) Recovery per Membrane : 10-15% f) Salt Rejection per Membrane : 98-99% g) Make of Membranes : Dow/Hydranautics, USA h) System Recovery : 60-65 % 8 RO PRESSURE TUBE To pack Reverse Osmosis Membranes and operate at high pressure up to 300 psi a) MOC : FRP 6

b) Diameter of Pressure Vessel : 8.2 inch c) Length of Pressure Vessel : 3.2 meters d) Thickness: 4 mm d) No. Pressure Vessels : 2 e) No. of Membrane per Vessel : 5 f) Make : wave cyber / Code line USA g) Position : Horizontal, Series h) Arrays : 5 No. 9 RO CLEANING SYSTEM 10 ELECTRICAL PANEL 11 INSTRUMENTATION We provide a flushing system, which shall help to clean the membrane and get rid of the foulness that get deposited on the membranes. a) Flushing Time : 15 minutes b) Flushing Media : Treated Water / Chemical c) Flushing Tank Size : 500 L d) Tank MOC : HDPE e) Flushing Pump :SS Pump will be used f) Semi automatic with two ball valves operation A control panel is provided as a safety measure for the pumps & other electrical items. a) Complete Starters, Overload relays, and single-phase preventor for Pump. b) Voltmeter, Ammeter, MCB s, indicating lights c) Push Buttons d) Rocker Switches for Dosers e) Incomers, Auto-Manual Switches 7

a) Flow Meter: To measure the online flow of water b) TDS Meter: To measure the online TDS of water c) Low Pressure Switch: To protect RO pump from dry running e) High Pressure Switch: To protect RO pump from back pressure f) Pressure Gauges: For calculate ^P for each unit in RO system Rota Meter : Quantity : 2 Nos.( permeate & reject line) Range : 30 cu.m. per hour Make : Flowstar, India/ Aster, India Digital TDS meter : Quantity : 1 No.(permeate line) Range : 0 500 PPM Optional Features : Make : Aster, India Pressure Switch : Quantity : 2 No.(Low & High) Range : 0-450 psi Make : Indfos, India Pressure Gauges : Quantity : 7 No. Range : 0 7 bar Dai Size : 6 inches Type : Bourdon Make : Feibig/Guru, India 12 ph DOSING SYSTEM To dose Sodium Bi-carbonate for enhance product water 8

PH. a) MOC : PP b) Capacity : 5 LPH c) Pressure : 7 Bar d) Qty. : 1 No. e) Make :Etatron DS,Italy 13 OZONATOR 1 no a) Capacity : 50 Gm/ Hr. b) Make : Creative Concept India c) MOC : SS 304 d) Quantity : 1 No 14 SS PUMP FOR OZONE BLENDING a) Capacity: 25000 LPH b) Make: Wilo / Kirloskar, c) MOC: Ozone resistant SS 304 15 U.V.Sterlizer a) Capacity : 25000 lph b) MOC : SS 304 c) Make : Standard with Philips d) Quantity : 1 No. 9

17 PLUMBING & FITTINGS a) Valves, pipelines RO module is in SS304 after MF, till the permeate line termination point. b) NRV s, pressure relief valves, wherever needed c) The System will be on common SS base frame. 10