SECTION THROUGH-PENETRATION FIRE STOP SYSTEMS

Similar documents
SECTION FIRESTOP SYSTEMS

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

FIRESTOPPING & SMOKE SEALS

St. Monica Food Pantry

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

SECTION PENETRATION FIRESTOPPING

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING

SECTION FIRESTOPPING

OUTLET PUTTY PADS SPECIFICATIONS

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION C 2012

SECTION FIRE RESISTIVE JOINT SYSTEMS

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 07 Thermal and Moisture Protection 8400 Firestopping

SECTION (07810) - APPLIED FIREPROOFING

A. Section includes Sprayed Fire-Resistive Materials: (SFRM) A. Pre-Installation Conference: Conduct conference at Project Site.

SECTION INTUMESCENT MASTIC FIREPROOFING

Blair Building Office Renovation - Sexual Offender Treatment Services (SORTS) M BA#16026 SECTION FIRESTOPPING

SECTION THROUGH-PENETRATION FIRESTOPPING

/ADF BuyLine 1632 FIREBARRIER FIRESTOP SYSTEMS

Over 98% of our products meet the requirements of the Buy American Act. Below is a list of our product categories that comply with this act.

SECTION JOINT SEALERS 1.03 THIS SECTION INCLUDES JOINT SEALERS FOR THE FOLLOWING LOCATIONS:

RECOMMENDED DESIGN SPECIFICATION

1. Division 15 Sections specifying duct and piping penetrations. 2. Division 16 Sections specifying cable and conduit penetrations.

SECTION INTUMESCENT FIREPROOFING

SECTION PENETRATION FIRESTOPPING PART 1- GENERAL PART 2- PRODUCTS 1.1 RELATED DOCUMENTS

Normal, Medium And High Density Fireproofing Materials

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

SECTION GYPSUM BOARD

SECTION JOINT SEALANTS

International Fireproof Technology Inc.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Life Hall Renovation Issued: July 9, 2014 Montclair State University Addendum No. 1 Owner's Project No Cannon Design Project No

Fire Protection Product Applications by Contractor Trades Through Penetrations & Joints

NEW CONSTRUCTION (digital copy available Firestop Solutions Inc.) FIRESTOPPING SPECIFICATION SECTION FIRESTOPPING

ARCHITECTURAL SPECIFICATION

SECTION APPLIED FIREPROOFING

SECTION BUILDING INSULATION. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION FIRE RESISTIVE JOINT SYSTEMS Display hidden notes to specifier. (Don't know how? Click Here)

SECTION APPLIED FIREPROOFING

FIRESTOP AND FIRE PROTECTION

Bid Opportunity Pacific Avenue, Winnipeg, Manitoba Page 1..1 CGSB 51-GP-23M-[78] Thermal Insulation, Urethane, Spray in Place.

A. Source Limitations: Obtain each type of building insulation through one source.

SECTION JOINT SEALANTS. A. Preparation of substrate surfaces to receive sealants.

International Fireproof Technology Inc.

BICSI March 19 th, 2009 Canadian Regional Meeting NBCC Moncton, New Brunswick. Firestop, it s not Magic It s understanding!

Request for Information (RFI) - 52

THERMAL AND MOISTURE PROTECTION

CAJ. Combos. C-AJ of 5. Through Penetrations Series. Concrete. 3Fire Protection Products

PRODUCT SPECIFICATIONS

E. Manufacturers Standardization Society of the Valve and Fittings Industry:

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 07 THERMAL AND MOISTURE PROTECTION

Firestop and Fire Protection Systems

SECTION BARRIER COAT FIREPROOFING. Display hidden notes to specifier. (Don't know how? Click Here)

The City of Winnipeg Section Bid Opportunity No Turtle Island Community Centre Renovation Page 1 of 6

SECTION Fiber Reinforced Stucco 1

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

07840 FIRESTOPPING AND SMOKE SEALING

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

C. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations.

NFCA 400 Field Quality Assurance Procedure for Application of Mastic and Thin-Film Intumescent Fire Resistive Coatings

University of Delaware

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO

SPECIFIER SHALL REMOVE COMMENTS IN BOLD TEXT PRIOR TO SUBMITTING.

IN2 Sleeves and Sleeve Seals for Electrical Raceways and Cabling

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

E. Manufacturers Standardization Society of the Valve and Fittings Industry:

FIRESTOP SUBMITTAL PACKAGE

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

SECTION INSULATION. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION JOINT SEALANTS PART 1 - GENERAL 1.01 RELATED DOCUMENTS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

IN2 Sleeves and Sleeve Seals for Communications Pathways and Cabling

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

FIRESTOP 101: An Introduction to Firestopping

Master Specification WALLTITE ECO v.2 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

SECTION Domestic Water Piping. A. American National Standards Institute (ANSI)/American Water Works Association (AWWA)

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

SECTION ROOFING AND SIDING PANELS

Protecting Penetrations in Fire Rated Construction

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

SECTION RESINOUS FLOORING

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Alply CLASSIC WALL Architectural Insulated Panel Wall System

A. This Section includes traffic coatings for the following applications:

Construction Standards PAGE

University of New Hampshire Scholars' Repository

PRODUCT CONTROL SECTION

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

Master Specification WALLTITE Eco v.3 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

SECTION SEALANTS AND CAULKING

SECTION TEXTURED COATINGS. A. Section includes textured coating for tilt-up panels.

SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING

Expansion Joint Covers (079513)

Expansion Joint Covers

SECTION ELASTOMERIC MEMBRANE ROOFING

Jean Vaillancourt Fire Protection Specialist Hilti (Canada) Corp.

SECTION CEMENTITIOUS WOOD FIBER DECKS

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

Transcription:

SECTION 07841 THROUGH-PENETRATION FIRE STOP SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Section includes firestopping and through-penetration system materials and accessories; firestopping tops of fire rated walls; and smoke sealing at joints between floor slabs and exterior walls. B. Firestopping of all penetrations and interruptions to fire rated assemblies, whether indicated on the Contract Drawings and/or specified herein or not, and other openings indicated. 1.02 SYSTEM DESCRIPTION A. Firestopping Materials: ASTM E119, ASTM E814, UL 263, UL 1479 to achieve fire ratings of adjacent construction in accordance with Factory Mutual (FM), Underwriters Laboratories Inc. (UL) and Warnock Hersey (WH) Design Numbers as noted on the Contract Drawings and/or specified herein. B. Surface Burning: ASTM E84, UL 723 with a maximum flame spread/smoke developed rating of 25/450. C. Firestop interruptions to fire rated assemblies, materials and components. 1.03 PERFORMANCE REQUIREMENTS A. Conform to applicable code FM, UL and WH for fire resistance ratings and surface burning characteristics. B. Provide certificate of compliance from jurisdiction authority indicating project materials approval. 1.04 REFERENCED SECTIONS A. Section 09260 Gypsum Board Assemblies. B. Section 09910 Painting Page 1 of 8

C. Division 15 Mechanical Mechanical work requiring firestopping. D. Division 16 Electrical: Electrical work requiring firestopping. 1.05 REFERENCED STANDARDS A. American Society for Testing and Materials (ASTM) 1. ASTM E 84 Standard Test Method for Surface Burning Characteristics of Building Materials. 2. ASTM E119 Standard Test Method for Fire Tests of Building Construction and Materials 3. ASTM E814 Standard Test Method for Fire Tests of Through- Penetration Firestops. B. Factory Mutual Engineering Corporation (FM) Fire Hazard Classifications. C. Underwriters Laboratories, Inc. (UL) 1. UL Fire Resistance Directory (FRD) current edition. 2. UL 263 Fire Tests of Building Construction and Materials. 3. UL 723 Test for Surface Burning Characteristics of Building Materials. 4. UL 1479 Fire Tests of Through-Penetration Firestops. 5. Warnock Hersey (WH) Directory of Listed Products. 6. Uniform Building Code (UBC), Current approved edition. 1.06 DEFINITIONS A. Firestopping (Through-Penetration Protection System): A sealing or stuffing material or assembly placed in spaces between and penetrations through building materials to arrest the movement of fire, smoke, heat and hot gases through firerated construction. 1.07 SUBMITTALS A. Specification Section 01330 Submittals: Submittal procedures. B. Product Data: Submit data on product characteristics, performance and limitation criteria. C. Schedule: Provide a schedule of opening locations and sizes, penetrating items and the required listed design numbers to seal openings to maintain the fire resistance rating of the adjacent assembly. Page 2 of 8

D. Manufacturer s Installation Instructions: Submit preparation and installation instructions. E. Engineering Judgements: For conditions not covered by UL or WH listed designs, provide judgements by a licenses professional engineer suitable for presentation to the jurisdiction authority for acceptance as meeting code fire protection requirements. 1.08 QUALITY ASSURANCE A. Fire Testing: Provide firestopping assemblies of designs which provide the specified fire ratings when tested in accordance with methods indicated. B. Manufacturer Qualifications: company specializing in manufacturing the products specified in this section with a minimum 5 years documented experience. C. Installer Qualifications: Company specializing in performing the work of this section with minimum 5 years experience. PART 2 PRODUCTS 2.01 QUALIFICATIONS A. Manufacturer: Company specializing in manufacturing products specified in this section with a minimum three years documented experience. 2.02 FIRESTOPPING ASSEMBLIES A. Firestopping: Any material meeting requirements. 1. Fire Ratings: Use any system listed by UL or tested in accordance with ASTM E814 that has an F Rating equal to the fire rating of penetrated assembly and minimum T Rating Equal to F Rating and that meets all other specified requirements. B. Acceptable Manufacturers 1. Dow Corning Corp. 2. 3M Fire Protection Products Page 3 of 8

3. Nelson Firestop Products 4. United States Gypsum Co. Model Thermafiber 5. Specified Technologies, Inc. C. Color: As selected from manufacturer s full range of colors. 2.03 MATERIALS A. Elastomeric Silicone Firestopping: Single component silicone elastomeric compound and compatible silicone sealant. a. A/D Fire Protection Systems, Inc. b. 3M Fire Protection Products. c. Specified Technologies, Inc. d. Or Approved Equivalent. B. Foam Firestopping: Single component foam compound. a. 3M Fire Protection Products. b. Specified Technologies, Inc. C. Fibered Compound Firestopping: Formulated compound mixed with incombustible non-asbestos fibers. a. A/D Fire Protection Systems, Inc. b. United States Gypsum Co. D. Intumescent Firestop Sealants and Caulks Putty: Compound which expands on exposure to surface heat gain. a. 3M Fire Protection Products Fire Barrier Caulk CP25WB+. b. Specified Technologies, Inc.(STI) SpecSeal S100 and S500 Sealant. c. International Protective Coatings Corp. E. Latex Firestop Sealant: Page 4 of 8

1. Acceptable Manufacturer: a. Specified Technologies, Inc.(STI) SpecSeal LC150 Sealant. F. Silicone Firestop Sealants and Caulks: G. Firestop Putty: a. Specified Technologies, Inc.(STI) SpecSeal Pensil 100 and 300. b. 3M Fire Protection Products Fire Barrier Silicone Sealants. c. Nelson CLK Firestop Sealant. H. Firestop Collars: a. Specified Technologies, Inc.(STI) SpecSeal Firestop Putty Bars and Pads. b. 3M Fire Protection Products Fire Barrier Moldable Putty. c. Nelson FSP Firestop Putty. I. Wrap Strips: a. Specified Technologies, Inc.(STI) SpecSeal Firestop Collars. b. 3M Fire Protection Products Fire Barrier PPD s. a. Specified Technologies, Inc.(STI) SpecSeal Wrap Strip. b. 3M Fire Protection Products Fire Barrier FS195 Wrap Strip. J. 2-Part Silicone Firestop Foam: K. Firestop Mortar: a. Specified Technologies, Inc.(STI) SpecSeal Pensil 200. b. 3M Fire Protection Products Fire Barrier 2001 Silicone Foam. Page 5 of 8

L. Composite Board: a. Specified Technologies, Inc.(STI) SpecSeal Mortar. b. Nelson CMP Firestop Compound. M. Firestop Pillows: a. 3M Fire Protection Products Barrier Sheet Material. b. Nelson CPS Composite Sheet. a. Nelson PLW Firestop Pillow. b. Specified Technologies, Inc.(STI) SpecSeal Firestop Pillows. 2.04 ACCESSORIES A. Primers, Sleeves and Forms: Type recommended by firestopping manufacturer for the specific substrate surfaces and suitable for the required fire ratings and required for tested assembly design. B. Dam Material: Permanent 1. Mineral Fiberboard. 2. Mineral fiber matting. C. Installation Accessories: Provide clips, collars, fasteners, temporary stops or dams and other devices required to position and retain materials in place. PART 3 EXECUTION 3.01 QUALIFICATIONS A. Applicator: Company specializing in performing the Work of this section with minimum three years documented experience and approved by the manufacturer. 3.02 ENVIRONMENTAL REQUIREMENTS Page 6 of 8

A. Do not apply materials when temperature of substrate material and ambient air is below 60 o F. B. Comply with firestopping manufacturer s recommendations and instructions for temperature and conditions during and after installation. Maintain minimum temperature before, during and for 3 days after installation of materials. C. Provide ventilation in areas where solvent-cured materials are being installed. 3.03 EXAMINATION A. Specification Section 01039 Coordination and Meetings: Coordination and project conditions. B. Verify openings are ready to receive the Work of this section. 3.04 PREPARATION A. Clean substrate surfaces of dirt, dust, grease, oil, loose material or other matter which may affect the bonding of the firestopping material. B. Remove incompatible materials which may affect the bond. C. Install backing damming materials to arrest liquid material leakage. 3.05 APPLICATION A. Install materials in the manner described in the fire test report and in accordance with the manufacturer s instructions, completely closing openings. B. Install material at fire rated construction perimeters and openings which contain penetrating sleeves, piping, ductwork, conduit and other items requiring firestopping. C. Apply primer where recommended by the manufacturer for the type of firestopping material and substrate involved and as required for compliance with the required fire ratings. D. Apply firestopping material in sufficient thickness to achieve the required fire and smoke rating to uniform density and texture. E. Compress fibered material to a maximum 40% of its uncompressed size. Page 7 of 8

F. Place foamed material in layers to ensure homogeneous density, filling cavities and spaces. Place sealant to completely seal junctions with adjacent dissimilar materials. G. Place intumescent coating in sufficient coats to achieve required rating. H. Dam material to remain. I. Do not cover installed firestopping until inspected by the A/E or Owner s Representative. J. Install labeling as required by the code. 3.06 CLEANING AND PROTECTION A. Specification Section 01770 Contract Closeout: Final cleaning B. Clean adjacent surfaces of firestopping materials. 3.07 PROTECTION OF INSTALLED CONSTRUCTION A. Specification Section 01770 Contract Closeout: Protecting installed construction. B. Protect adjacent surfaces from damage by material installation. END OF SECTION 07841 Page 8 of 8