Energy And Exergy Analysis Of Fully Condensing Steam Turbine At Various Steam Load Condition

Similar documents
Energy Analysis of 12.5 MW Co-generation plant at Porbandar

Lecture No.1. Vapour Power Cycles

Lecture No.3. The Ideal Reheat Rankine Cycle

Chapter 10 VAPOR AND COMBINED POWER CYCLES

Chapter 10 POWER CYCLES. Department of Mechanical Engineering

ME ENGINEERING THERMODYNAMICS UNIT III QUESTION BANK SVCET

Chapter 10. In Chap. 9 we discussed gas power cycles for which the VAPOR AND COMBINED POWER CYCLES. Objectives

Energy and Exergy Analysis of Boiler and Extraction cum Condensing Steam Turbine in Sugar Cogeneration Plant

Chapter 10. In Chap. 9 we discussed gas power cycles for which the VAPOR AND COMBINED POWER CYCLES. Objectives

Chapter 1 STEAM CYCLES

ENERGY AND EXERGY ANALYSIS OF A 250MW COAL FIRED THERMAL POWER PLANT AT DIFFERENT LOADS

PERFORMANCE ANALYSIS OF A STEAM POWER PLANT OPERATING UNDER SUPERHEATED AND ISENTROPIC CONDITIONS

Practice Final Exam (A) Six problems. (Open-book, HW solutions, and notes) (Plus /minus 10 % error acceptable for all numerical answers)

External and Internal Irreversibility

Application of Exergy Analysis. Value and Limitations

CHAPTER 1 BASIC CONCEPTS

Consider a simple ideal Rankine cycle with fixed turbine inlet conditions. What is the effect of lowering the condenser pressure on

Chapter 9: Vapor Power Systems

Problems in chapter 9 CB Thermodynamics

Energy and Exergy Analysis of a 250 mw Coal Thermal Power Plant at Design Load Conditions

UNIVERSITY OF TORONTO FACULTY OF APPLIED SCIENCE AND ENGINEERING FINAL EXAMINATION, DECEMBER 2008 MIE 411H1 F - THERMAL ENERGY CONVERSION

PARAMETRIC STUDY OF GAS TURBINE CYCLE COUPLED WITH VAPOR COMPRESSION REFRIGERATION CYCLE FOR INTAKE AIR COOLING

FEE, CTU in Prague Power Engineering 2 (BE5B15EN2) Exercise 3

Thermoelectric Design

R13 SET - 1 '' ''' '' ' '''' Code No: RT31035

Thermodynamic Simulation of Steam Power Cycles using GUI- MatLab Interfaces

Efficiency improvement of steam power plants in Kuwait

- 2 - SME Q1. (a) Briefly explain how the following methods used in a gas-turbine power plant increase the thermal efficiency:

EFFECT OF AMBIENT TEMPERATURE, GAS TURBINE INLET TEMPERATURE AND COMPRESSOR PRESSURE RATIO ON PERFORMANCE OF COMBINED CYCLE POWER PLANT

Vapor and Combined Power Cycles

MEM 310 Design Project Assignment

Improvement of distillation column efficiency by integration with organic Rankine power generation cycle. Introduction

OPTIMIZATION OF PARAMETERS FOR HEAT RECOVERY STEAM GENERATOR (HRSG) IN COMBINED CYCLE PLANTS

Exergy in Processes. Flows and Destruction of Exergy

Energy and Exergy Analysis of Coal Fired Thermal Power Plant.

Chapter 1 Basic Concepts

2. The data at inlet and exit of the turbine, running under steady flow, is given below.

Second Law Based Thermodynamic Analysis of Cogeneration Plant

Reading Problems , 11.36, 11.43, 11.47, 11.52, 11.55, 11.58, 11.74

THERMODYNAMIC ANALYSIS OF A FLUIDIZED BED COAL COMBUSTOR STEAM PLANT IN TEXTILE INDUSTRY

ANALYSIS OF DIFFERENT TYPES OF REGULATION AND ITS EFFICIENCY IN STEAM POWER CYCLES MASTER THESIS

Chapter 6: Stationary Combustion Systems

AC : HANDS-ON EXPERIENCE WITH RANKINE CYCLE IN THE THERMAL SCIENCE LABORATORY COURSE

ME 331 Thermodynamics II

Reg. No. : Question Paper Code : B.E./B.Tech. DEGREE EXAMINATION, NOVEMBER/DECEMBER Second Semester

EXTRA CREDIT OPPORTUNITY: Due end of day, Thursday, Dec. 14

MECHANICAL ENGINEERING DEPARTMENT, OITM

Thermodynamic Analysis of Organic Rankine Cycle using Different Working Fluids

a. The power required to drive the compressor; b. The inlet and output pipe cross-sectional area. [Ans: kw, m 2 ] [3.34, R. K.

EXERGETIC ANALYSIS OF SOLAR AIDED COAL FIRED (210MW) THERMAL POWER PLANT

Exergy Based Analysis of an Open Cycle Gas Turbine Power Plant

PERFORMANCE ANALYSIS OF REHEATED GAS TURBINE BASED POWER PLANT CYCLE

Engineering Thermodynamics

Parametric Study of a Double Effect Absorption Refrigeration System

ASSIGNMENT 2 Coal and Ash Handling System and Draught Systems

Stationary Combustion Systems Chapter 6

Exergy Analysis of 210 Mw of Vijayawada Thermal Power Station (V.T.P.S)

Hydrogen oxygen steam generator integrating with renewable energy resource for electricity generation

PI Heat and Thermodynamics - Course PI 25 CRITERION TEST. of each of the following a. it

Eng Thermodynamics I - Examples 1

Chapter 10 Vapor and Combined Power Cycles

K.S. Rawat 1, H. Khulve 2, A.K. Pratihar 3 1,3 Department of Mechanical Engineering, GBPUAT, Pantnagar , India

DE-TOP User s Manual. Version 2.0 Beta

R13. II B. Tech I Semester Regular/Supplementary Examinations, Oct/Nov THERMODYNAMICS (Com. to ME, AE, AME) Time: 3 hours Max.

Performance Optimization of Steam Power Plant through Energy and Exergy Analysis

MUZAFFARPUR INSTITUTE OF TECHNOLOGY COURSE FILE OF THERMODYNAMICS FACULTY NAME: AMIT KUMAR ASSISTANT PROFESSOR DEPARTMENT OF MECHANICAL ENGINEERING

COMPARATIVE ANALYSES OF TWO IMPROVED CO 2 COMBINED COOLING, HEATING, AND POWER SYSTEMS DRIVEN BY SOLAR ENERGY

R13. (12M) efficiency.

Applied Thermo Fluids-II: (Autumn 2017) Section-A: Thermal Power Plants

Exergetic Sensitivity Analysis of ORC Geothermal Power Plant Considering Ambient Temperature

Eng Thermodynamics I - Examples 1

Available online at ScienceDirect. Energy Procedia 110 (2017 )

Performance of a Gas Turbine Power Plant

MODIFICATIONS OF STEAM POWER PLANT INTO COMBINED CYCLE BY INTRODUCING LNG AS FUEL

Thermodynamic analysis on post combustion CO 2 capture of natural gas fired power plant

Second Law Analysis of a Carbon Dioxide Transcritical Power System in Low-grade Heat Source Recovery

Electrical Energy Production from the Waste Heat Released the Gas Turbine Beaings Cooled with Oil using the Organic Rankine Cycle

S.E. (Mechanical) (First Semester) EXAMINATION, 2012 APPLIED THERMODYNAMICS (2008 PATTERN) Time : Three Hours Maximum Marks : 100

CHAPTER 8 CONCLUSIONS

Pinch Analysis for Power Plant: A Novel Approach for Increase in Efficiency

Technical and economical feasibility of the Rankine compression gas turbine (RCG)

MODELING THERMODYNAMIC ANALYSIS AND SIMULATION OF ORGANIC RANKINE CYCLE USING GEOTHERMAL ENERGY AS HEAT SOURCE

International Journal of Advance Engineering and Research Development

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM IV (ME-41, 42,43 & 44)] QUIZ TEST-1 (Session: )

Optimization of operating parameters for a 600MW Rankine cycle based Ultra Supercritical power plant

MCG THERMODYNAMICS II. 22 April 2008 Page 1 of 7 Prof. W. Hallett

Energy Analysis of Omotosho Phase 1 Gas Thermal Power Plant

CHAPTER 4 STEAM TURBINE and CYCLE HEAT BALANCE

Potential of Allam cycle with natural gas to reduce carbon dioxide emission in India

Faculty of Engineering 2 nd year 2016 Mechanical Engineering Dep. Final-exam (code: M 1222)

Exergy Analysis Of Thermal Power Plant; A Review

International Journal of Advance Engineering and Research Development

water is typically used as the working fluid because of its low cost and relatively large value of enthalpy of vaporization

HW-1: Due Tuesday 13 Jun 2017 by 2:00:00 pm EDT to Your Division s GradeScope Site

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

CHAPTER 1 BASIC CONCEPTS THEORY

Bagasse based high pressure co-generation in Pakistan

Rankine cycle. Contents. Description

Introduction to Aerospace Propulsion. Prof. Bhaskar Roy. Prof. A. M. Pradeep. Department of Aerospace Engineering

Thermodynamic Analysis on Gas Turbine Unit

Transcription:

International Journal of ChemTech Research CODEN( USA): IJCRGG ISSN : 0974-4290 Vol.5, No.2, pp 957-963, April-June 2013 ICGSEE-2013[14 th 16 th March 2013] International Conference on Global Scenario in Environment and Energy Energy And Exergy Analysis Of Fully Condensing Steam Turbine At Various Steam Load Condition A.H.Rana 1, J.R.Mehta 2 * Mechanical Engineering Department, Faculty of Technology and Engineering, The M.S.Unirsity of Baroda,Vadodara, Gujarat(India). *Corres.author: jrmehta1999@gmail.com Abstract: The power is very vital factor for development of any nation. Energy resources are limited in stock and its present consumption rate is in increasing trend. There fore energy efficiency and energy conservation are prime important. More over the technology largely used today to produce electricity from coal causes significant negative environmental impacts. Energy and exergy analysis are used to analyse the performance of thermal systems. Energy analysis deals with quantity aspect whereas exergy analysis deals with quality and quantity aspects of energy. Exergy analysis focuses on magnitude and location of energy loss. In this analysis energy efficiency, exergy destructions, exergy efficiency and turbine heat rates are evaluated at 40%, 50%, 60%, 70 % and 80 % Maximum continuos rating condition of steam turbine. Analysis shows that operating turbine at 80 attract plant heat rate improvement by 1356.72 kj/kwh, which reduce environmental CO 2 emission by 1907.79 kg/h, SO 2 emission by 43.66 kg/h and ash generation by 122.58 kg/ h. Keywords: Energy efficiency; Exergy efficiency; Exergy destruction; CO 2 emission; Heat rate; Steam Turbine; SO 2 emission. I. Introduction The steam power plant supply 57 % of total power demand in India. The Coal being the major source of energy to produce steam and to generate power in steam power plant.the energy conversion efficiency of steam power plant is low and while burning coal creates environmental emissions 1.Therefore efficiency enhancement of coal to electric power generation is major issue of steam power plant. Inefficient use of coal not only waste resource but create environmental pollution issues such as CO 2, SO 2 and NO X emissions. Hence energy conservation is paramount important. Energy Conservation mainly focused energy efficiency. The first law of thermodynamics is normally used to analyze the energy utilization, but it doesn t use the quality aspect of energy. Exergy is the consequent of second law of thermodynamics. It is a property that enables us to determine the useful work potential of a given amount of energy at some specified state. A thorough understanding of exergy and the insights it can provide into the efficiency, environmental impact and sustainability of energy systems. Exergy analysis has been widely used in design, simulation and performance evaluation of thermal and thermo-chemical systems 2,3.

J.R.Mehta et al/int.j.chemtech Res.2013,5(2) 958 Fig.1 Interdisciplinary triangle covered by exergy analysis 4 Steam power plant working on rankine cycle. This utilizes steam as a working medium to produce electrical power. This ideal cycle is friction less and not having any internal irreversibility. Rankine Cycle consists of the following four processes: isobaric heat addition in a boiler, isentropic expansion in a turbine, isobaric heat rejection in a condenser, and isentropic compression in a pump 5. Superheated steam is produced in a boiler by utilizing the heat of combustion process. Assuming an open system, the high pressure forces the steam to the turbine where it expands isentropically and we get work by the rotation of the turbine shaft. The turbine is coupled with gear speed reducer and out put shaft of gear speed reducer is again coupled to electric generator. So by rotation of turbine shaft, generator rotate and electrical power is produced. The steam then exhausted into a condenser, where cooling medium absorbs the latent heat of steam and convert it to a saturated liquid (Condensate) 5. In actual rankine cycle, the expansion of steam in steam turbine is not isentropic due to various internal irreversibilities. There fore entropy generation during steam expansion process ceases the second law efficiency. Steam turbine system is usually analyzed by energy analysis which uses first law, in this analysis energy efficiency and plant heat rate are worked out. But better understanding is attained when a more complete thermodynamic view is taken, which utilises the second law analysis (Exergy Analysis) 6. This study is focused on energy and exergy analysis of 22 MW fully condensing Steam Turbine. Energy efficiency, Plant heat rate, Exergy destruction and Exergy efficiencies are worked out at different load conditions such as 40%, 50%, 60%, 70 % and 80 % Maximum continuous rating condition of steam turbine. The effect of turbine heat rate improvement on coal consumption, ash generation, environment pollution such as CO 2 and SO 2 emissions are also discussed. II. Methodology This section presents equations for energy and exergy analysis.it also present schematic diagram (Fig.2) and experimental data (Tab. 1). 1. Energy And Exergy Efficiency Relations The expression of energy efficiency (First law efficiency - ɳ I ) and exergy efficiency (Second law efficiency - ɳ II ) for the fully condensing steam turbine are based on the following definitions, First Law Efficiency, ɳ I % = (Ė in- Ė out ) / Ė in (1) Exergy Efficiency, ɳ II % = Ψ out / Ψ in = ( Ψ power ) / ṁ i (h i - T o S i ) (2) Exergy Destruction, Ψ d = Ψ in - Ψ out - Ψ power kj/s (3) 2. Plant Heat Rate Considering Boiler Efficiency HR = ṁ i ( h i - hw ) / (Power x ɳ Boiler ) kj/kwh (4) 3. Coal Saving Coal saving =HR Improvement x Gen.Power / GCV (5) 4. Co2 Emmision Reduction CO 2 emission reduction =3.66 x % C coal x Coal saving kg/h (6)

J.R.Mehta et al/int.j.chemtech Res.2013,5(2) 959 5. So2 Emmision Reduction SO 2 emission reduction =2 x Sulphur % in coal x Coal saving kg/h (7) 6. Ash Generation Reduction\ Ash Gen. Reduction = Coal saving x % ash in coal kg/h (8) 7. The Reference Environment Exergy is always evaluated with respect to a reference environment. The reference environment is in stable equilibrium, acts as an infinite system, and is a sink or source for heat and materials, and experience only internal reversible processes, in which its intensive properties (i. e. temperature T 0, pressure P 0 ) remains constant. In this analysis surrounding temperature and pressure are taken as T 0 =34 0 C and P 0 =101.325 kpa as based on weather and climate condition at Bhavnagar, Gujarat (India). 8. Data of Steam Turbine Data for study is taken at 40%, 50%, 60%, 70 % and 80 (Maximum Continuous Rating) of Fully Condensing Steam Turbine working at Nirma Ltd., Bhavnagar, Gujarat. The boiler of this power plant is fired by coal blend having lignite (70%) & Indonesian coal (30%) and c oal firing rate is 10.5 kg/s. The Ultimate analysis of coal blend is as follows, C - 44.65%, N2-1.21%, H2-3.06%, O2-10.8%, S - 1.87%, Ash - 10.5%, Moisture - 27.78% and GCV of coal is 4226 Kcal/kg (17664.68 kj/kg). Table I: Experimental Data of Steam Turbine Sr. No. Particular Unit Value at 40 Value at 50 % MCR Value at 60 Value at 70 % MCR Value at 80 1 Main Steam Flow Ton Per Hour 34.00 41.00 48.00 56.00 65.00 2 Main Steam Pressure kg/cm 2 109.00 107.00 109.00 107.00 101.00 3 Main Steam Temperature 0 C 497.00 493.00 496.00 497.00 494.00 4 Enthalpy of Inlet Steam kj / kg 3355.20 3347.30 3352.60 3357.70 3357.70 5 Entropy of Inlet Steam kj/kg K 6.53 6.53 6.53 6.55 6.57 6 Exhaust Steam Flow Ton Per Hour 34.00 41.00 48.00 56.00 65.00 7 Exhaust Steam Pressure kg/cm 2-0.92-0.92-0.91-0.92-0.90 8 Exhaust Hood (Steam) Temperature 0 C 44.50 44.56 46.50 45.50 48.30 9 Enthalpy of Exhaust Steam kj / kg 2341.80 2341.90 2345.80 2319.90 2313.60 10 Entropy of Exhaust Steam kj/kg K 7.41 7.41 7.39 7.32 7.25 11 Condensate (Feed Water) Enthalpy kj / kg 186.21 186.46 194.56 190.38 202.08 12 Turbine Power KW 8881.96 11050.81 13219.66 15698.34 18590.14 13 Generator Power KW 8600.00 10700.00 12800.00 15200.00 18000.00 Assumptions: 1. There is no steam loss across steam turbine. 2. Gear box efficiency as per manufacturer 98.40 % 3. Generator efficiency as per manufacturer 98.03 % 4. Boiler efficiency is 83.53 % 5. Condensate is reused as feed water in boiler. 9. Steam Turbine Main Specifications 7 Manufacturer: Hang Zhou Steam Turbine Co. Limited, China Model & Type: HNK/ 50/63/56 Nominal Rating: 20000 KW Nominal Speed: 5408 rpm Maximum allowable steam flow: 8100 kg/h Maximum allowable steam temperature: 525 0 C Maximum allowable steam pressure: 110 bar

J.R.Mehta et al/int.j.chemtech Res.2013,5(2) 960 Maximum Power at Max. Steam flow: 2200 KW Normal Exhaust steam pressure: -0.916 bar Normal Exhaust steam temperature: 48.6 0 C Number of stages: (1+32) / (Impulse + Reaction) Governor Manufacturer: Wood Ward Governor Type: Electric & Hydraulic 10.Schematic Diagram of Steam Turbine III. Calculation Energy Calculation For 80 % Mcr Fig.2 Process Flow Diagram of Condensing Steam Turbine 1. Energy Input : Ė i = ṁ i x h i = 65 x 1000 x 3357.70 / 3600 = 60625.13 kj/s. 2. Energy Output: Ė o = ṁ exh x h exh = 65 x 1000 x 2313.60 / 3600 = 41773.33 kj/s. 3. Work done: W.D = Ė i - Ė o =60625.13-41773.33 = 18851.80 Kw 4. Actual Power develop by turbine: P = Generator power x ɳ -1 gearbox x ɳ -1 generator = 18000 x (0.984) -1 x (0.9803) -1 = 18590.14 Kw 5. Energy efficiency (First Law Efficiency) of turbine: ɳ I = Net Work done by turbine/ Energy input = (Ė i - Ė o )/ Ė i = 18851.80 / 60625.13 = 30.66 % 6. Plant Heat Rate Considering Boiler Efficiency 8 HR = Net Heat Input /Generator Power = 65 x 1000 (3357.70 202.08) / 18000 =13642.15 kj/kwh 7. Coal Saving due to Heat Rate improvement: Coal Saving = HR Improvement x Gen.Power / GCV = 1356.72 x 18000 / 17664.68 = 1167.42 kg/h

J.R.Mehta et al/int.j.chemtech Res.2013,5(2) 961 8. CO 2 emission reduction due to Heat Rate improvement: CO 2 emission reduction = 3.66 x % C coal x Coal saving kg/h 9 = 3.66 x 0.4465 x 1167.42 = 1907.7942 kg/h 9. SO 2 emission reduction due to Heat Rate improvement: SO 2 emission reduction = 2 x Sulphur % in coal x Coal saving kg/h 10 = 2 x 0.0187 x 1167.42 = 43.66 kg/h 10. Ash Generation Reduction due to Heat Rate improvement: Ash Gen. Reduction = Coal saving x % ash in coal kg/h = 1167.42 x 0.105 = 122.57 kg/h Exergy Calculation For 80 % Mcr 1. Exergy Input : Ψ in = ṁ i (h i -T 0 S i ) = 18.06 (3357.70 -(307x 6.57)) = 24213.22 kj/s. 2. Exergy out : Ψ out = ṁ exh (h exh -T 0 S exh ) = 18.06 (2313.60-(307x7.25)) = 1586.57 kj/s. 3. Exergy Destruction Steam Turbine : Ψ des = Ψ in - Ψ out - Ψ Turbine Power = 24213.22-1586.57 18590.14 = 4036.51 kj/s. 4. Exergy Efficiency (Second Law Efficiency) of Steam Turbine : ɳ II = Ψ power / Ψ in =18590.14 / 24213.22 = 76.78 %. IV. Result And Discussion Table II: Experimental Result 22 MW Condensing Steam Turbine S N Particulars Value at 40 Value at 50 Value at 60 Value at 70 Value at 80 % MCR 1 Energy Efficiency % 28.03 28.99 29.57 30.06 30.66 2 Exergy Destruction 3223.26 3470.83 3716.28 4151.94 4036.51 (kj/sec) 3 Exergy Efficiency % 69.73 72.30 73.59 74.82 76.82 4 Heat Rate (kj/kwh ) 14998.88 14499.97 14177.72 13969.92 13642.16 5 Improved Heat Rate 0 498.91 821.16 1028.96 1356.72 (kj/kwh ) 6 Coal Saving kg/h 0 242.90 497.40 745.60 1167.42 7 CO 2 emission reduction 0 396.94 812.85 1218.44 1907.79 kg/h 8 SO 2 emission reduction 0 9.08 18.60 27.89 43.66 kg/h 9 Ash generation reduction kg/h 0 25.50 52.23 78.29 122.58

J.R.Mehta et al/int.j.chemtech Res.2013,5(2) 962 The experimental result shows that as steam and power load on steam turbine increases its energy and exergy efficiency increases. Energy efficiency increased by 2.63 % and exergy efficiency by 7.09 % during 40 to 80 turbine operation. Fig.3 Grass man diagram for exergy flow through Steam Turbine at 80 The exergy destruction during 40 to 80 condition is increased by 813.25 kj/s. The exergy destruction is mainly due to steam turbine irreversibilities. Real steam expansion process is away from ideal isentropic process in steam turbine due to internal friction. The energy efficiency is remarkably lower in all cases because leaving steam from turbine carrying considerable amount of energy that is purely waste in condenser. There is an improvement observed in plant heat rate by 1356.72 kj/kwh at 80 compare to 40 % MCR turbine operation. Coal saving is achieved due to this heat rate improvement by 1167.42 kg/h. Coal saving further reduced ash handling plant load by 122.58 kg/h and more improved life of plant because ash is highly erosive in nature. This creates mechanical wear during handling. Improved heat rate at 80 turbine operation lead to CO 2 emission reduction by 1907.79 kg/h and SO 2 emission reduction by 43.66 kg/h. V. Conclusion Acknowledgment Energy and exergy efficiencies are higher at higher MCR operation of turbine. Exergy loss is 25.30 % and 16.67 % as corresponding to 40 % and 80 turbine operation. Coal consumption reduced by 1167.42 kg/h Ash handling plant load reduced by 122.58 kg/h CO 2 emission reduced by 1907.79 kg/h SO 2 emission reduced by 43.66 kg/h The support for this work provided by Shri G.J.Adroja, Shri D.G.Jakhade,Shri L.M.Mavani, Shri D.R.Fondekar, Shri K.N.Pandya and Shri H.V.Mendpara of The Nirma Ltd, Kalatalav, Bhavnagar, Gujarat (India) is gratefully acknowledged. References 1. Ministry of Power,Govt. of India, 2. Web site,www.powermin.nic.in/indian_electricity_scenario.(accessed on 7/12/2012) 3. Ganapathy T, Alagumurthi N, Gakkhar RP, Murugesan K, Exergy analysis of operating lignite fired thermal power plant, Journal of Engineering Science and Technology Review 2009; 2:123 30.

J.R.Mehta et al/int.j.chemtech Res.2013,5(2) 963 4. Kanoglu, M, Dincer, I, Rosen, M A., 2007, Understanding energy and exergy efficiencies for improved energy management in power plants. Energy Policy 35, 3967 3978. 5. Rosen, M.A., Dincer I.2001, Exergy as the confluence of energy, environment and sustainable development,exergy, an International Journal 1(1), 3-13. 6. Y. A. Çengel and M. A. Boles, Thermodynamics: An Engineering Approach, 5th ed, McGraw-Hill, 2006,Chap 10,553-554. 7. I.Dincer and M.Rosen, Energy, Exergy and Sustainable Development, Elsevier, 2007, Chap- 12,257-265. 8. Hang Zhou Steam Turbine Co. Limited, China, Data Manual of Steam Turbine Model - HNK/ 50/ 63/56,Doc.No.1116-02-2350. Bureau of Energy Efficiency, Ministry of Power Govt. of India, Energy Auditor guide book, vol 4,2005,Chap-3,45-53. 9. P Chattopadhyay, Boiler Operation Engineering, 2nd ed, McGraw-Hill, 2000, Chap-10,314. 10. N.C.Pandya and NC.S.Shah, Heat Engines,9 th ed,charotar Publishing House,Anand, 1990, Chap-13, 594. *****