Validation of ENVI-met PMV values by in-situ measurements

Similar documents
Assessment of Thermal Comfort in Respect to Building Height in a High-Density City in the Tropics

Cool spots in hot climates: a means to achieve pedestrian comfort in hot climates

Watts in a comfort index:

4.2 PHYSIOLOGICALLY EQUIVALENT TEMPERATURE AND CLIMATE CHANGE IN FREIBURG

BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

Greener & Cooler. Thermal comfort as ecosystem service in the urban forest of Florence, Italy

Mitigating and adapting thermal stress with urban green - Quantification with measurements and micro scale models. Andreas Matzarakis

Case Study: Bio-Climatic Building Design for Tropical Climates

Passive Cooling Design Options to Improve Thermal Comfort in an Urban District of Rome, Under Hot Summer Conditions

Urban microclimate and thermal comfort evaluation

Workshop: Architecture-Tradition and Modernization. Climate Responsive Urban Design

Thermal Comfort in Architecture

Central Arizona-Phoenix Long-Term Ecological Research Project

Activity report Simulation survey (Villaggio Artigiano)

Designing Air-Distribution Systems To Maximize Comfort

Influence of Urban Morphology on Outdoor Thermal Comfort in Summer: A Study in Tunis, Tunisia

Optimizing Indoor Environments for Occupant Satisfaction. Presented by: Kelli Goldstone April 2016

Trees Configuration Model for Hot Humid Tropic Urban Parks

Assessing The Microclimate of Green and Less-Green Tropical Landscape Environment

Macro and Micro Climate Climate

Work environment. Microclimate - definition. Main microclimate elements. Core temperature. Microclimate

10 minutes temperatures vary on local scales

The influence of the surrounding environment on the building s energy performance

Thermal Delight in Architecture

Use of a mobile platform for assessing urban heat stress in Rotterdam

Thermal Delight in Architecture

Field investigation on indoor thermal environment of a high-rise condominium in hot-humid climate of Bangkok, Thailand

Bio-climatic Chart for Different Climatic Zones of Northeast India

Impact of Vegetation on Urban Microclimates

Bioclimatic approaches of modern residential architecture in Cyprus,

POST OCCUPANCY DESIGN INERVENTION TO IMPROVE COMFORT AND ENERGY PERFORMANCE IN A DESERT HOUSE

Thermal comfort comparison and evaluation in different climates

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Research on indoor thermal environment of stilted buildings in Chongqing, China

! #! %%%%&%%% &( &% )) + # +,% #.!. # 0! 1 2! ,%,% 0 # 0! 1 2! ,4&,) 5,%

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

The Urban Environment and Climate Change

Micheal Okpara University of Agriculture Umudike. Abstract

Available online at ScienceDirect. Procedia Engineering 145 (2016 ) 18 25

COMPARISON OF THE STANDARDIZED REQUIREMENTS FOR INDOOR CLIMATE IN OFFICE BUILDINGS

Towards green design guidelines for thermally comfortable streets

Environmental Impacts of Urban Heat Islands and their Countermeasures - Experiences of Japanese dense cities-

Urban Climate. Prof. Dr. Lutz Katzschner Environmental Meteorology Department Faculty of Architecture and Planning University Kassel / Germany

A STUDY ON THE COOLING EFFECTS OF GREENING FOR IMPROVING THE OUTDOOR THERMAL ENVIRONMENT IN PENANG, MALAYSIA

Energy and Thermal Comfort Management in a Kindergarten School Building in the South of Portugal in Winter Conditions

The utilization of first derivatives and violinplots of meteorological parameters for the evaluation of thermal behavior of small urban sites.

SPATIAL URBAN CLIMATE AND URBAN PLANNING UNDER CONSIDERATION OF GLOBAL CLIMATE CHANGE. Prof. Dr. Lutz Katzschner University Kassel Germany

ABSTRACT INTRODUCTION

Experimental investigation of zero energy office under natural and forced ventilation

GREEK TRADITIONAL BIOCLIMATIC ARCHITECTURE

Outdoor Thermal Comfort in the Hot Arid Climate The effect of socio-economic background and cultural differences

Influence of trees on the air temperature in outdoor spaces according to planting parameters: the case of the city of Aix-en-Provence in France

USING CERAMIC TILES ON THE WALLS OF A BUILDING AS MITIGATION MODEL FOR URBAN HEAT ISLAND

Ethiopian Journal of Environmental Studies and Management Vol. 6 Supplement 2013

ENERGY STRATEGIES IN THE TROPICAL CONTEXT THE USE OF SIMULATION TOOLS IN INFORMING URBAN BIOCLIMATIC DESIGN IN A MALAYSIAN HIGHRISE DEVELOPMENT

CropSyst Modelling Solution. Reference documentation

ARCH-MEDES (I) CONSULTANTS PVT. LTD. Green Park Delhi

681: Environmentally Responsive Architecture; Passive Design for School in Southern India

CONTENTS. Introduction x

Bioclimatic landscape design in extremely hot and arid climates

IMPLICATIONS OF CLIMATE CHANGE AND OCCUPANT BEHAVIOUR ON FUTURE ENERGY DEMAND IN A ZERO CARBON HOUSE

Human thermal comfort below the canopy of street trees on a typical Central European summer day

Thermal comfort and psychological adaptation as a guide for designing urban spaces

Thermal Comfort Evaluation of HDB flats

ScienceDirect. Influence of the balcony glazing construction on thermal comfort of apartments in retrofitted large panel buildings

Urban Greening and the UHI: Seasonal Trade-offs in Heating and Cooling Energy Consumption in Manchester, UK

MODELLING THE URBAN MICROCLIMATE AND ITS INFLUENCE ON BUILDING ENERGY DEMANDS OF AN URBAN NEIGHBOURHOOD

A Field Study of the Thermal Environment in Residential Buildings in Harbin

Microclimate Effects of Urban Geometry on Outdoor Thermal Comfort in the Brazilian Tropical Semi-arid Climate

Heating, Cooling, Lighting: Sustainable Design Methods for Architects

LINKE TURBIDITY FACTOR FOR BRAŞOV URBAN AREA

Natural Ventilation Approached on Circular Courtyard Building in Hot Humid Climate

Estimation of the extreme meteorological and hydrological conditions in Slovenia in the future

Evaluation of Stability for Ecological Revetment Method with Stone Mattress and Vegetation Mound Using ANSYS Fluent

The Earth s Global Energy Balance

AN ASSESSMENT OF CONDITIONS OF HUMAN COMFORT IN OPEN LANDSCAPED AREAS OF LODZ OCENA KOMFORTU CZŁOWIEKA W STREFIE NIEZABUDOWANEJ ŁODZI

Integration of Energy Efficiency Through Architectural Design. Presentation by TERI. 10 th June,2010

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Volume 8, ISSN (Online), Published at:

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Properly situated homes pay big dividends

Heat Stress Monitor by using Low-Cost Temperature and Humidity Sensors

Integrated BIPV performance assessment for tropical regions: a case study for Bangalore

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

Crop Water Use Program for Irrigation

A student investigated the efficiency of a motor using the equipment in Figure 1. Figure 1

Weather and Oceans: Uneven Heating of the Earth

CFD/FEM Based Analysis Framework for Wind Effects on Tall Buildings in Urban Areas

Factors affecting evaporation 3/16/2010. GG22A: GEOSPHERE & HYDROSPHERE Hydrology. Several factors affect the rate of evaporation from surfaces:

OFFICE DE CONSULTATION PUBLIQUE DE MONTRÉAL

A Case Study on Suitable Area and Resource for Development of Floating Photovoltaic System

ENERGY AND THERMAL COMFORT EVALUATION FOR DIFFERENT PASSIVE SOLUTIONS IN A KINDERGARTEN IN SUMMER CONDITIONS.

Heat Exposure Study in the Workplace in a Glass Manufacturing Unit in India

Earth, Wind & Fire Natural Airconditioning [1] Research objectives and Methods

A Study on the Operational Status of the Chamber for Testing the Thermal Performance of Curtain Walls

NUMERICAL SIMULATION OF CAR COCKPIT HEATING DURING WINTER 1

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Thermal Comfort & Green Buildings. Dr. Ommid Saberi. "Green Retrofit Conference. WSP Environment & Energy (Middle East)

External Environment and Indoor Microclimate

Introduction to Environmental Physics

Calibration of outdoor thermal comfort models

Transcription:

Validation of ENVI-met values by in-situ measurements Dain Jeong 1, Kyunghun Park 2*, Bonggeun Song 3, Gyeongah Kim 4, Chulhyun Choi 5, Byunghyun Moon 6 Dain, Jeong 1 Department of Environmental Engineering of Changwon National University, 20 Changwondaehak-ro Uichang-gu Changwon-si, Gyeongsangnam-do 641-773, Rep. of KOREA, dohundain@naver.com 2* Department of Environmental Engineering of Changwon National University, 20 Changwondaehak-ro Uichang-gu Changwon-si, Gyeongsangnam-do 641-773, Rep. of KOREA, landpkh@changwon.ac.kr *corresponding author 3 National Institute of Ecology, 1210 Geumgang-ro Maseo-myeon Seocheon-gun, Chungcheongbuk-do 325-813, Rep. of KOREA, bgsong@nie.re.kr 4 Department of Environmental Engineering of Changwon National University, 20 Changwondaehak-ro Uichang-gu Changwon-si, Gyeongsangnam-do 641-773, Rep. of KOREA, wing1128@naver.com 5 department of landscape Architecture of Kyungpook National university, 80 Daehak-ro, Buk-gu, Daegu, Republic of Korea, 702-701, Kenix@naver.com 6 Department of Environmental Engineering of Changwon National University, 20 Changwondaehak-ro Uichang-gu Changwon-si, Gyeongsangnam-do 641-773, Rep. of KOREA, bhmoon@changwon.ac.kr 1. Introduction The increased use of artificial paving, such as concrete and asphalt, has contributed to the deterioration of the thermal environment of urban areas. Moreover, it has caused changes in the microclimate of those areas, such as heat waves in summer, and the 'heat island effect'. Problems caused by changes in the microclimate bring about discomfort for urban dwellers and pedestrians and increase the demand for spaces with more comfort. Thermal comfort is the mental state of feeling satisfied with the ambient environmental conditions. In order to improve the thermal comfort of an urban space, waste heat needs to be reduced and the evapotranspiration of the urban green spaces needs to be increased.[1] Furthermore, the additional heat from artificial paving should be reduced to a minimum. Therefore, rather than understanding the thermal environment only by measuring the microclimate, human psychological and physiological factors should also be considered to solve the issue of thermal comfort.[2] Many studies have been conducted worldwide on the thermal comfort and the heat stress experienced by people in- and outdoors. More than 40 thermal comfort indices have been developed and applied, including WBGT (Wet Bulb Globe Temperature), WCT (Wind Chill Temperature), and DI (Discomfort Index). Recent additions are (Predicted Mean Vote) and PET (Physiological Equivalent Temperature), which are used for statistical calculations on the human thermal sensation in an actual environment. The (Predicted Mean Vote) index conceived by P. Ole Fanger is used to calculate the thermal load of the human body and to describe the extent of warm and cold sensations. The is regarded as more sensitive than the other indices. For this study, we used the index to measure thermal comfort, as the considers both the microclimate components (temperature, humidity, air velocity, and mean radiant temperature) and the subjective features of an individual, such as metabolism and the amount of clothing worn. In general, the range is between 3.5 and +3.5, while the comfort range is between 0.5 and +0.5. In addition to the thermal comfort indices, microclimate models, such as ENVI-met and Rayman, which can calculate and project the thermal comfort indices, have been developed and used [3,4]. However, simulation by a microclimate model cannot fully represent the complex urban spaces of the actual world. Consequently, verification is needed on the accuracy of the modeling results in comparison with the actual situation [5]. In South Korea, many researchers have studied the thermal environment using microclimate models, but the results obtained have not often been verified by comparison with data obtained from in-situ observations. Therefore, this research aims to verify the accuracy of ENVI-met, based on the on-site observation of. Depending on whether the ENVI-met modelling results demonstrate adequate accuracy, our ultimate goal is to bring about and assess the thermal comfort of various places, using gained from the ENVI-met microclimate modeling.

2. Methodology 2.1 Study area This research was conducted at the pedestrian spaces and the square on the campus of the Changwon National University of South Korea(Fig. 1). The university is located at latitude 35 14'N and longitude 128 41 E, in the south of the country. Although the target location was small, it was chosen for its diverse spa tial properties, such as different paving, green spaces, d areas, and open spaces. In additi on, it was convenient for mobile measurements and for applying an ENVI-met model, which simulates a s mall space. Figure 1. Research location Figure 2. Mobile measurement equipment 2.2 Research process First, we consulted domestic and international studies on thermal comfort. We examined the theories of t hermal comfort and the research methods relevant to in-situ measurements and microclimate simulation. S ubsequently, we selected the research location, the spots for the mobile measurements, and the microclim ate components were measured, which include temperature, humidity, air velocity, and the MRT, measured by the black-globe thermometer, needed to project. Thereafter, operating the ENVI-met modeling on the same day, we compared the differences and the characteristics of each space. Finally, we analyzed t he accuracy of the ENVI-met model, based on the in-situ measurements. 2.3 In-situ measurements To calculate, we performed mobile measurements of the microclimate from 08:00 to 17:00 on Sept ember 20, 2014 and from 10:00 to 16:00 on June 1, 2015. On September 20, 2014, the temperature was relatively too high for autumn in South Korea, and the thermal environment was considered unpleasant. T he maximum temperature during the day was 27 C and the weather was clear, with almost no clouds. O n June 1, 2015, the start of summer in South Korea, the maximum temperature was 28 C. We spent les s than two hours on each mobile measurement. Because of the time differences in the mobile measurem ents between the measurements spots, it was necessary to adjust the measurements to take into account the time differences. We corrected the resultant values, using a correction formula in relation to the mobil e measurements. We measured the microclimate components, such as temperature, humidity, air velocity, and the black-globe thermometer. The measurements were made at five-second intervals with Testo 480(F ig. 2), which was set up vertically and 1.2 m from the ground. The various paving, surrounding buildings, trees, and the d areas were considered in selecting the spots for the mobile measurement s. We selected 27 spots on September 20, 2014 and 20 spots on June 1, 2015. We considered metaboli sm and clothing as individual variables to calculate. Since the selected places were meant for pedes trians, we set the level of metabolism at 2.0met, which is usual for slow walking. Taking into account the weather on the day of measuring, we set the amount of clothing at 0.7clo, relevant to light tropical clothin g.

2.4 Microclimate modeling The ENVI-met model used for this research is a three-dimensional microclimate analysis program. Data f or this model, such as information on the buildings, paving, and vegetation are entered in a grid at the level of the urban canopy layer of an urban environment. The model can predict the distribution of the temperature, humidity, radiant energy, air current, and fluid flow at a micro scale. Two input data sets, i.e., an IN file (input file) and a CF file (main configuration file) are needed for an ENVI-met simulation. An IN file constructs the spatial properties of the target area, such as the geographical location, the mate rials and heights of the buildings, the types of vegetation, and the paving. For the purposes of o ur research, we set the size of the research area at 388m wide and 168m high, and the size of the grid at 2m. In addition, we entered the digitized information on the height of the buildings, pavement types, an d vegetation, using orthographic projection of aerial photographs. The CF file enters the initial meteorologic al values, such as the date and time of the measurement, temperature, humidity, and wind velocity. We e ntered the data as shown in Table 1. We used the 3.5 version of the ENVI-met model for the simulation, while the Leonardo 2014 program was used for the deduction and analysis of the data. Table 1. ENVI-met CF file (configuration file) setting Parameter 2014.09.20 2015.06.01 Simulation date 2014.09.20 2015.06.01 Simulation time 06:00~18:00 06:00~18:00 State time 60 60 Ta (air temperature) 299.3 K 300.5 K RH, Relative humidity 32% 53% V, Wind velocity 1.6m/s at 10m height 0.9m/s at 10m height Wind direction West West Roughness Length Z0 at Reference point 0.1 0.1 3. Results and Discussion 3.1 The results of in-situ measurements We set the basis for our analysis on the measurements taken at 13:00 and 15:00 on September 20, 2014 and at 12:00 and 14:00 on June 1, 2015. The in-situ measurements at 13:00 on September 20, 2014 for spot no. 27, which is close to buildings and has a grass pavement, indicated 4.8, the most unpleasant level(table 2). We presume that because spot no. 27 was close to the buildings, it was affected by both the radiant energy from the buildings and the radiant energy from the sun. In contrast, the of spot no. 8 was 1.03, which is the most pleasant level. This area is paved with soil and d by buildings. At 15:00, spot no. 3 was the most unpleasant, and spot no. 6 was the most pleasant. Spot no. 3, an open space, did not have adequate compared with the other spots; therefore, we conjecture that its value was caused by radiant energy from the sun. As the measurements at 12:00 on June 1, 2015 indicate, spot no. 17, which has a grass pavement and is in direct sunlight, exhibited the most unpleasant level, while spot no. 6, which has a grass pavement and is d by trees, exhibited the most pleasant level(table 3). We presume that as spot no. 17 is situated close to buildings, it was affected by both radiant energy from the sun and radiant energy from the buildings. Spot no. 9, with similar properties to those of spot no. 17, was affected by radiant energy from the nearby buildings. However, because of provided by trees, it was relatively more pleasant than was spot no. 17. Nevertheless, while the other d spots measured at the same time exhibited a value of 2.5 on average, spot no. 9 exhibited a value of 3.95, which is regarded as quite problematic. We surmise that this spot was affected more by the radiant energy from buildings than were the other spots. At 14:00, spot no. 18, paved with clay blocks and receiving direct sunlight, exhibited the highest value, while spot no. 6, paved with grass and d by both trees and buildings, was the most pleasant.

Table 2. measurements on September 20, 2014, spot 13:00 15:00 spot 13:00 15:00 1 Asphalt Building 1.29 Building 1.27 15 Clay block x 3.73 x 2.82 2 Clay block x 3.64 x 2.87 16 Asphalt x 3.88 x 3.06 3 Clay block x 3.29 x 3.94 17 Asphalt Building 1.78 Building 1.04 4 Clay block Tree 1.88 Tree 1.47 18 Clay block x 3.24 x 2.38 5 Clay block Building 1.32 Building 0.96 19 Clay block x 4.19 x 2.81 6 Clay block Building 1.19 Building 0.85 20 Wooden deck x 3.85 Tree 1.34 7 Grass Building 1.24 Building 0.96 21 Asphalt x 4.33 x 2.67 8 Soil Building 1.01 Building 1.03 22 Concrete x 3.42 x 2.62 9 Grass x 2.96 x 2.93 23 Grass Tree 2.95 x 2.07 10 Soil x 3.83 x 3.32 24 Clay block x 3.95 Building 1.09 11 Grass x 3.15 Tree 2.20 25 Clay block x 3.75 x 1.90 12 Grass x 3.61 x 3.26 26 Clay block x 3.68 x 2.29 13 Urethane x 4.06 x 3.77 27 Grass x 4.80 x 2.52 14 Stone slab (gray) x 3.75 x 2.38 Spot 12:00 14:00 Spot 12:00 14:00 1 Asphalt x 3.05 x 4.23 11 Wooden panel x 4.25 x 4.52 2 Clay block Tree 2.76 x 3.85 12 Grass Tree 2.55 Tree 2.66 3 Clay block x 3.69 x 3.80 13 Grass x 4.24 x 3.84 4 Clay block Tree 2.42 Tree 2.34 14 Urethane x 4.17 x 4.68 5 Clay block x 4.21 Building 2.46 15 Asphalt x 4.41 x 4.16 6 Grass Tree 2.26 Table 3. measurements on June 1, 2015, Building & Tree 2.16 16 Asphalt x 4.19 Building 2.45 7 Grass x 3.68 x 3.64 17 Grass x 4.76 x 4.17 8 Grass x 2.97 x 4.40 18 Clay block x 4.55 x 4.74 9 Grass Tree 3.95 x 4.30 19 Asphalt x 3.42 x 4.29 10 Clay block x 3.84 x 4.05 20 Concrete x 3.84 x 3.77 3.2 Results of ENVI-met, comparison of in-situ measurements, and analysis of their correlativity From the ENVI-met output data, we extracted the temperature, humidity, wind velocity, and Mean Radiant Temperature, necessary for calculating, in order to compare the in-situ measurements with the resul ts from the ENVI-met modeling. We compared the measurements conducted at 13:00 and at 15:00 on Se ptember 20, 2014, and the measurements conducted at 12:00 and 14:00 on June 1, 2015(Fig. 2). After c omparing the value of the ENVI-met model and the value of the in-situ measurements, we fou nd that relevant to the measurements at 13:00 on September 20, 2014, the of the in-situ measurem ents was generally higher than was the of the ENVI-met model. Verifying the accuracy, using a scatt er diagram distribution, indicated that in most cases the R² was 0.601(Fig. 3). Unlike the measurements at 13:00, the at 15:00 exhibited similar values for both the in-situ measurements and the ENVI-met m odeling. However, large differences were found between some other pots, and the R² was 0.480. Therefor e, it appears that the measurements at 13:00 were slightly more accurate than were the measurements at

15:00. As regards the large difference between the values from the in-situ measurements and the values from the ENVI-met modeling, it is surmised that there were errors in the ranges of the provided b y the trees and buildings, and the pixel size of the modeling did not produce an adequate resolution. On June 1, 2015, the R² value was 0.403 at 12:00 and 0.614 at 14:00. The measurements at 14:00 were mo re accurate than were the measurements at 12:00. As with the measurements on September 20, 2014, th e measurements on June 1, 2015 tended to be similar at most of the spots. However, in relation to the tr ees, the range of and the degree of blocking the sun were dissimilar, depending on the height, wat er pipes, and the leaf size. The differences are attributed to the inability of the modeling to represent real situations exactly. (a) 1p.m. on September 20 (b) 3p.m. on September 20 (c) 12p.m. on June 1 (d) 2p.m. on June 1 Figure 2 Comparison of between In-situ and ENVI-met on September 20, June 1, 4. Conclusions In this research, we performed in-situ measurements and ENVI-met modeling at the pedestrian paths on the university campus on September 20, 2014 and on June 1, 2015. We compared the thermal comfort in spaces with different properties, and verified the accuracy of the of the in-situ measurements and the of the ENVI-met modeling. As regards the in-situ measurement, the values differed, depending on the spatial properties. In summer, comfort largely depended on the presence or absence of sunlight. In particular, the provided by buildings resulted in more comfort than did the provided by trees. It appears that solar radiant energy is more effectively blocked by buildings than it is by trees. At the location directly exposed to radiant energy from the sun and situated near buildings, the level of thermal comfort was quite low in comparison with the other locations. This is attributable to the radiant energy from the sun, the buildings, and the surface of the earth. The results of a comparison of the of ENVI-met and the of the in-situ measurements show that the R² was 0.601 at 13:00 and 0.480 at 15:00 on September 20, 2014,while it was 0.403 at 12:00 and 0.614 at 14:00 on June 1, 2015. The results of modeling and the values from the in-situ measurement were mostly similar; however, at some specific spots, they were quite dissimilar. As urban areas have complicated and diverse spatial characteristics, modeling does not adequately represent the actual situations. In order to improve the accuracy of modeling, the paving, trees, and the building types of the target locations need to be studied in more detail and the information obtained have to be entered as data. If the accuracy of modeling is improved in future, it could be

expected to more accurately predict the thermal comfort of various spatial conditions. ENVI-met can also be used to plan urban spaces that afford more comfort and to improve less comfortable spaces. (a) 1p.m. on September 20 (b) 3p.m. on September 20 (c) 2p.m. on June 1 (d) 2p.m. on June 1 Figure 3. Scatter Plots of between In-situ and ENVI-met on September 20, June 1 Acknowledgment This research was supported by Basic Science Research Program through the National Research Foundation of Korea(NRF) funded by the Ministry of Education (NRF-2013R1A1A2008033) References [1] Lee, J. A., 2010: An evaluation of human thermal comfort and improvement of thermal environment by spatial structure. Journal of the Korean Institute of Landscape Architecture, 38(5), 12-20 [2] Joo, C. H., Yoon, Y. H., 2008: The Influence of land cover types on thermal comfort in urban openspace. Journal of Korean Society for People Plants and Environment, 11(46), 59-65 [3] Epstein, Y., Moran, D. S., 2006: Thermal comfort and the heat stress indices. Industrial Health, 44, 388-398 [4] Lee, C. S., Ryu, N. H., 2014: The Comparison of the Solar Radiation and the Mean Radiant Temperature(MRT) under the Shade of landscaping Trees in Summertime. Journal of the Korean Institute of Landscape Architecture, 42(5), 22-30 [5] Song, B. G., Park, K. H., 2014: Validation of ENVI-met model with in situ measurements considering spatial characteristics of land use types. Journal of the Korean association of geographic information studies, 17(2), 156-172 [6] Fanger, P. O., 1972: Thermal comfort : Analysis and Applications in Environmental Engineering, New York: McGraw-Hill