SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

Similar documents
ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

Aliphatic Acrylic-Polyester Polyurethane

1.1 This Section includes surface preparation and the application of base coats, intermediate and topcoats.

Refer to Substrates & Surface Preparation.

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

SECTION 1045 PAINT FOR STRUCTURAL STEEL

PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Coating Types. Coating Systems. Coating Basics. Why coatings are used Component of coatings Methods of protection Service environment

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

1.4 kg/l (11.4 lb/us gal) Maximum 295 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) 50 to 63 μm (2.0 to 2.

Tnemec Standard Paint Schedule

ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

Associated Spec Consultants, Inc. February 27, 2014 SECTION ARCHITECTURAL COATINGS

INDUSTRIAL PAINTING SCHEDULE GUIDE

TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING

Florock Seamless Flooring Systems

DURASHIELD 310 &

Section COATING RESTORATION

Pacific Polymers Elasto-Deck BT Guide Specification

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

SECTION EPOXY RESIN FLOORING

SECTION EPOXY RESIN FLOORING

Valspar InspireME Coil and Extrusion Product Guide Specification Section Shop-Applied Coatings for Metal

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

SECTION EPOXY FLOORING SYSTEMS

GRIP-GARD PLUS BRUSH / ROLL ADDITIVE

Corlar LV PR 178 Series Epoxy Primer

SECTION RESILIENT SHEET FLOORING

- Aromatic hydrocarbons - Binder 2,67 kg/dm³ (±0,06 Kg/dm³) Solid content - 80% by weight (±2%) - 58% by volume (±2%) according to ASTM D2697

Application Guidelines

Engine Bay Floors Floor Resurfacing 4000

PRODUCT GUIDE SPECIFICATION

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

SECTION A. American Society for Testing and Materials (ASTM):

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

RUST TRAP TECHNICAL DATA SHEET

To ensure warranty eligibility, each job must be approved by American WeatherStar before it begins.

GigaCrete Specification PlasterMax. PlasterMax : Fire Rated Plaster for Direct Application over Cement Masonry Units (CMU) Interior Walls

Specifier Notes: Edit the following list as required by the project. List other sections with work directly related to the floor coating.

***********************************************************************************

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

SECTION EPOXY TERRAZZO

RUST TRAP TM TECHNICAL DATA SHEET

2 COMPONENT LIQUID WATERPROOFING PART 1 GENERAL. A. Two component liquid waterproofing for positive side waterproofing on mineral substrates

Pre-qualification testing in accordance with NORSOK M-501, Rev. 5, System 1, suitable for exterior exposure in offshore environment, below 120 C.

Product Guide Specification

Priming and Painting Slip Critical Steel Connections. Troy Fraebel Corrosion Specification Specialist

Frank D. Rea Director of Coatings Services / Chief Chemist

Corrosion, Coatings and Hydropower

two component high build amine adduct cured phenolic epoxy primer

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-US/Hong Kong. US EPA method 24 (tested)

SECTION JOINT SEALANTS PART 1 - GENERAL 1.01 RELATED DOCUMENTS

Maximum Rust Protection!

SECTION HYDRAULIC CEMENT UNDERLAYMENT

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1

Cleaning and Protecting Concrete Surface Preparation, Application, and Inspection. NESMEA October 17, 2017 Kenneth A. Trimber KTA-Tator, Inc.

STERI-COAT P. Multi Functional, Pigmented High Build Epoxy Novolac Coating, For Wall & Ceiling Applications mils GREEN BUILDING FEATURES

Normadur 65 HS. Technical Data PROPERTIES AND RECOMMENDED USAGE TECHNICAL DATA

Property Test/Standard Description

The Application Guide offers product details and recommended practices for the use of the product.

Kolorines Glass Mosaic Tiles Project Specification

3MTM FireDamTM Intumescent Coating WB Installation Manual. Thinner is. Better

Property Test/Standard Description

Technical Data Sheet

Rust Bullet Home and Farm FAQ s

Instruction Guide APPLICATION OF CIM TO CONCRETE

FLUID APPLIED WATERPROOFING

DIVISION 9 FINISHES Section Floor Finishes

KOSTER AMERICAN CORPORATION

SSPC: The Society for Protective Coatings. Commercial Blast Cleaning

Joint Surface Preparation Standard. NACE No. 3/SSPC-SP 6 Commercial Blast Cleaning

Table of Contents. List of Drawings

Interior Painting Artesi II & III Day Care Facilities at 777 & 333 W. Matthews Road

Avoiding Fading Paint

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-EU EU VOC Directive 2004/42/CE (theoretical) 14 g/l

The required quality of surface preparation can vary depending on the area of use, expected durability and if applicable, project specification.

Series - 1

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

FOR STEEL POTABLE WATER TANKS INTERIOR AND EXTERIOR CORROSION PROTECTION. Hydro-Zinc

PRODUCT DATA SHEETS CUSTOM COATINGS FORMULATED TO MATCH YOUR NEEDS USCOATINGS.COM // St. Louis, Missouri

SECTION CONCRETE AND MASONRY COATINGS

1.5 SUBMITTALS A. General: Submit samples, product data, shop drawings, warranties and certificates in accordance with

The University of Oklahoma Kuhlman Ct. Water Tower November 17, 2017 Coating and Painting Water Tanks OU Project #42-18

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.

University of Missouri St. Louis UMSL Project No. S Thomas Jefferson Library Elevator R&B Project No: Renovation & Repairs

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

2018 Flooring Specification - Tile Set Method TECTURA DESIGNS CEMENT TERRAZZO TILES

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.

Bharat Heavy Electricals Limited Piping Centre Chennai-17. Specification Number Revision Number Sheet Number PC:E:GF: of 7 CONTENTS

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

Transcription:

- 1 - SECTION 099600 High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes) PART 1 GENERAL 1.1 SECTION INCLUDES A. Systems for field applied acrylic urethane coatings; opaque and metallic finishes. 1.2 REFERENCES A. ASTM D 16 - Terminology Relating to Paint, Varnish, Lacquer, and Related Products. B. SSPC-SP 1 - Solvent Cleaning. C. SSPC-SP 2 - Hand Tool Cleaning. D. SSPC-SP 3 - Power Tool Cleaning. E. SSPC-SP 6/NACE 3 - Commercial Blast Cleaning. F. SSPC-SP 10 - Near White Blast Cleaning G. SSPC-SP 13 Concrete Surface Preparation 1.3 DEFINITIONS A. Definitions of Painting Terms: ASTM D 16, unless otherwise specified. 1.5 SUBMITTALS A. Comply with Section 01330 - Submittal Procedures. B. Product Data: Submit manufacturer's product data for each coating, including generic description, complete technical data, surface preparation, and application instructions. C. Manufacturer s Quality Assurance: Submit manufacturer s certification that coatings comply with specified requirements and are suitable for intended application. D. Warranty: Submit manufacturer s standard warranty. High Performance Coatings Field Applied 09960-1

- 2-1.6 QUALITY ASSURANCE A. Manufacturer s Qualifications: 1. Manufacture of coatings shall demonstrate a minimum of 10 years successful experience. 2. Manufacture shall supply a list of successful performance on comparable projects. 3. Source Responsibility: Coatings and coating application accessories shall be products of a single supplier. B. Applicator s Qualifications: 1. Experienced in application of specified coatings for a minimum of 2 years on projects of similar size and complexity to this Work. 2. Applicator's Personnel: Supervisory personnel shall be trained in the successful application of the specified coatings. 1.7 DELIVERY, STORAGE, AND HANDLING A. Delivery: Deliver materials to site in manufacturer's original, unopened containers and packaging, with labels clearly identifying: 1. Coating or material name. 2. Manufacturer. 3. Color name and number. 4. Batch or lot number. 5. Date of manufacture. 6. Mixing and thinning instructions. B. Storage: 1. Store materials in a clean, dry area and within temperature range in accordance with manufacturer's instructions. 2. Keep containers sealed until ready for use. 3. Do not use materials beyond manufacturer s shelf life limitations. C. Handling: Protect materials during handling and application to prevent damage or contamination. 1.8 ENVIRONMENTAL REQUIREMENTS A. Weather: 1. Air and Surface Temperatures: Prepare surfaces and apply and cure coatings within air and surface temperature range in accordance with manufacturer s instructions. 2. Surface Temperature: Minimum of 5 degrees F (3 degrees C) above dew point. 3. Relative Humidity: Prepare surfaces and apply and cure coatings within relative humidity range in accordance with manufacturer s instructions. 4. Precipitation: Do not prepare surfaces or apply coatings in rain, snow, fog, or mist. 5. Wind: Do not spray coatings if wind velocity is above manufacturer s limit. B. Ventilation: Provide ventilation during coating evaporation stage in confined or enclosed areas in accordance with manufacturer s instructions. C. Dust and Contaminants: 1. Schedule coating work to avoid excessive dust and airborne contaminants. 2. Protect work areas from excessive dust and airborne contaminants during coating application and curing. High Performance Coatings Field Applied 09960-2

- 3 - PART 2 PRODUCTS 2.1 Material shall be as manufactured by Precision Coatings Incorporated (PCI), Springfield, MO 2.1.1 Represented by Pacific Southwest Supply, Inc., Brea, CA (562) 691 9600 2.2 COATING SYSTEMS FOR STEEL - INTERIOR A. Interior Acrylic Urethane Finish Solid Color, Pearl or Metallic : Mild Abuse Interior : Less than 250 grams per liter 2. Surface Preparation: SSPC-SP 2 and SSPC-SP3 Hand tool and power tool clean. 3. Primer: [PCI DTM 1300 Sanding Primer DFT 2.0 to 6.0 mils] [PCI DTM 1400 Non-Sanding Primer DFT 1.5-3.0 mils] 5. Total DFT: 3.0 to 9.0 mils. Low VOC Mild Abuse Interior: Less than 100 grams per liter 1. System Type: direct to metal polyurethane primer / aliphatic acrylic 3. Primer: [PCI DTM 3000 Primer DFT 1.5 to 3.0 mils] 5. Total DFT: 2.5 to 5.5 mils. High Abuse Interior: Less than 250 grams per liter 3. Primer: [PCI DTM 1300 Sanding Primer DFT 2.0 to 6.0 mils] [PCI DTM 1400 Non-Sanding Primer DFT 1.5-3.0 mils] 4. Intermediate Coat: [PCI DTM 1300 Sanding Primer DFT 2.0 to 6.0 mils] [PCI DTM 1400 Non-Sanding Primer DFT 1.5-3.0 mils] 5. Finish Coat: [PCI PC3V100 Matte Finish] [PCI PC3V100 Satin Finish] [PCI High Performance Coatings Field Applied 09960-3

- 4-6. Total DFT: 5.0 to 16.0 mils. 2.3 COATING SYSTEMS FOR STEEL EXTERIOR A. Exterior Acrylic Urethane Finish Solid Color, Pearl or Metallic: Mild Atmospheric Exterior: Less than 250 grams per liter 2. Surface Preparation: SSPC-SP 2 and SSPC-SP3 Hand tool and power tool clean. 3. Primer: [PCI DTM 1300 Sanding Primer DFT 2.0 to 6.0 mils] [PCI DTM 1400 Non-Sanding Primer DFT 1.5-3.0 mils] 5. Total DFT: 3.0 to 9.0 mils. Low VOC Mild Abuse Exterior: Less than 100 grams per liter 1. System Type: direct to metal polyurethane primer / aliphatic acrylic 3. Primer: [PCI DTM 3000 Primer DFT 1.5 to 3.0 mils] 5. Total DFT: 2.5 to 5.5 mils. High Abuse Exterior: Less than 250 grams per liter 3. Primer: [PCI DTM 1300 Sanding Primer DFT 2.0 to 6.0 mils] [PCI DTM 1400 Non-Sanding Primer DFT 1.5-3.0 mils] 4. Intermediate Coat: [PCI DTM 1300 Sanding Primer DFT 2.0 to 6.0 mils] [PCI DTM 1400 Non-Sanding Primer DFT 1.5-3.0 mils] 5. Finish Coat: [PCI PC3V100 Matte Finish] [PCI PC3V100 Satin Finish] [PCI 6. Total DFT: 5.0 to 16.0 mils. Coastal Zone, Corrosive Environment, High Abuse Exterior: SCAQMD compliant 1. System Type: organic zinc epoxy primer / epoxy ketamine intermediate / aliphatic acrylic High Performance Coatings Field Applied 09960-4

- 5-3. Primer: [Amercoat 68HS] DFT 3 to 4 mils 4. Intermediate Coat: [PCI DTM 1300 Sanding Primer DFT 2.0 to 6.0 mils] [PCI DTM 1400 Non-Sanding Primer DFT 1.5-3.0 mils] 5. Finish Coat: [PCI PC3V100 Matte Finish] [PCI PC3V100 Satin Finish] [PCI 6. Total DFT: 5.5 to 16.0 mils. 2.4 COATING SYSTEMS FOR CONCRETE AND MASONRY - INTERIOR A. Interior Acrylic Urethane Finish Solid Color, Pearl or Metallic : Moderate Conditions, Physical Contact and/or Abuse, Wall and Non-Floor Areas: 1. System Type: direct to concrete epoxy-ketamine primer / aliphatic acrylic 2. Surface Preparation: SSPC-SP 13 3. Primer: [PCI DTM 1300 Sanding Primer DFT 4.0 to 6.0 mils] 5. Total DFT: 5.0 to 9.0 mils. Moderate to Severe Conditions, Physical Contact and/or Abuse, Wall and Non-Floor Areas: 1. System Type: direct to concrete epoxy-ketamine primer / aliphatic acrylic 2. Surface Preparation: SSPC-SP 13 3. Primer: [PCI DTM 1300 Sanding Primer DFT 4.0 to 6.0 mils] 4. Intermediate: [PCI DTM 1300 Sanding Primer DFT 4.0 to 6.0 mils] 5. Finish Coat: [PCI PC3V100 Matte Finish] [PCI PC3V100 Satin Finish] [PCI 6. Total DFT: 9.0 to 11.0 mils. 2.5 COATING SYSTEMS FOR CONCRETE AND MASONRY - EXTERIOR A. Exterior Acrylic Urethane Finish Solid Color, Pearl or Metallic : Mild to Moderate Conditions, Physical Contact and/or Abuse, Wall and Non-Floor Areas: 1. System Type: direct to concrete epoxy-ketamine primer / aliphatic acrylic 2. Surface Preparation: SSPC-SP 13 3. Primer: [PCI DTM 1300 Sanding Primer DFT 4.0 to 6.0 mils] 5. Total DFT: 5.0 to 9.0 mils. High Performance Coatings Field Applied 09960-5

- 6 - Moderate to Severe Conditions, Physical Contact and/or Abuse, Wall and Non-Floor Areas: 1. System Type: direct to concrete epoxy-ketamine primer / aliphatic acrylic 2. Surface Preparation: SSPC-SP 13 3. Primer: [PCI DTM 1300 Sanding Primer DFT 4.0 to 6.0 mils] 4. Primer: [PCI DTM 1300 Sanding Primer DFT 4.0 to 6.0 mils] 5. Finish Coat: [PCI PC3V100 Matte Finish] [PCI PC3V100 Satin Finish] [PCI PC3V100 Semi-Gloss Finish] [PCI PC3V100 High Gloss Finish]. DFT 1.0 to 6. Total DFT: 9.0 to 11.0 mils. 2.6 COATING SYSTEMS FOR GALVANIZED STEEL AND NONFERROUS METAL Interior or Exterior A. Interior / Exterior Acrylic Urethane Finish Solid Color, Pearl or Metallic : Atmospheric Interior Overhead Deck, Ductwork, Conduit, Dry: Less than 250 grams per liter 2. Surface Preparation: Treat the surface with PCI Metal Conditioner to remove galvanize process preservatives or lightly abrasive blast to remove galvanize process preservatives. 3. Primer: [PCI DTM 1300 Sanding Primer DFT 2.0 to 6.0 mils] [PCI DTM 1400 Non-Sanding Primer DFT 1.5-3.0 mils] 4. Finish Coat: [PCI PC3V100 Matte Finish] [PCI PC3V100 Satin Finish] [PCI PC3V100 Semi-Gloss Finish] [PCI PC3V100 High Gloss Finish]. DFT 1.0 to 5. Total DFT: 3.0 to 9.0 mils. 2.7 COATING SYSTEMS FOR GYPSUM BOARD - INTERIOR A. Interior Acrylic Urethane Finish Solid Color, Pearl or Metallic: 1. Low VOC Mild Abuse Interior: Less than 100 grams per liter 2. System Type: Acrylic primer / aliphatic acrylic 3. Surface Preparation: Level 5 Drywall Finish. 4. Primer: Frazee 168 Prime Plus Primer DFT 1.5 to 3.0 mils] 5. Finish Coat: [PCI PC3V100 Matte Finish] [PCI PC3V100 Satin Finish] [PCI PC3V100 Semi-Gloss Finish] [PCI PC3V100 High Gloss Finish]. DFT 1.0 to 6. Total DFT: 2.5 to 5.5 mils. 7. Finish Color: [ ] [As indicated on the drawings] 2.9 ACCESSORIES A. Coating Application Accessories: 1. Accessories required for application of specified coatings in accordance with High Performance Coatings Field Applied 09960-6

- 7 - manufacturer s instructions, including thinners. 2. Products of coating manufacturer: 1. [PCI 12030 Urethane Accelerator] 2. [PCI 15000 Surface Tension Eliminator] 3. [PCI 16050 VOC Exempt Reducer] 4. [PCI 17000 VOC Exempt Gun Cleaner] 5. [PCI 02150 Metal Conditioner] PART 3 EXECUTION 3.1 EXAMINATION A. Examine areas and conditions under which coating systems are to be applied. Notify Architect of areas or conditions not acceptable. Do not begin surface preparation or application until unacceptable areas or conditions have been corrected. 3.2 PROTECTION OF SURFACES NOT SCHEDULED TO BE COATED A. Protect surrounding areas and surfaces not scheduled to be coated from damage during surface preparation and application of coatings. B. Immediately remove coatings that fall on surrounding areas and surfaces not scheduled to be coated. 3.3 SURFACE PREPARATION OF STEEL A. Prepare steel surfaces in accordance with manufacturer s instructions. B. Fabrication Defects: 1. Correct steel and fabrication defects revealed by surface preparation. 2. Remove weld spatter and slag. 3. Round sharp edges and corners of welds to a smooth contour. 4. Smooth weld undercuts and recesses. 5. Grind down porous welds to pinhole-free metal. 6. Remove weld flux from surface. C. Ensure surfaces are dry. D. Remove visible oil, grease, dirt, dust, mill scale, rust, paint, oxides, corrosion products, and other foreign matter in accordance with SSPC-SP 6/NACE 3, unless otherwise specified. E. Abrasive Blast-Cleaned Surfaces: Coat abrasive blast-cleaned surfaces with primer before visible rust forms on surface. Do not leave blast-cleaned surfaces uncoated for more than 8 hours. F. Shop Primer: Prepare shop primer to receive field coat in accordance with manufacturer s instructions. 3.4 SURFACE PREPARATION OF CONCRETE AND MASONRY A. Prepare concrete and masonry surfaces in accordance with manufacturer s instructions, High Performance Coatings Field Applied 09960-7

SSPC-SP 13/NACE 6, and ICRI 03732. - 8 - B. Ensure surfaces are clean, dry, and free of oil, grease, dirt, dust, and other contaminants. C. Test concrete for moisture in accordance with ASTM D 4263 and F 1869. D. Allow concrete and mortar to cure for a minimum of 28 days before coating and determine that concrete is dry enough to coat. E. Level protrusions and mortar spatter. 3.6 SURFACE PREPARATION OF GALVANIZED STEEL AND NONFERROUS METAL A. Prepare galvanized steel and nonferrous metal surfaces in accordance with manufacturer s instructions. Surface preparation recommendations will vary depending on substrate and exposure conditions. 3.7 SURFACE PREPARATION OF GYPSUM BOARD A. Prepare gypsum board surfaces in accordance with Level 5 Drywall Finish. B. Ensure surfaces are clean, dry, and free of oil, grease, dirt, dust, and other contaminants. C. Sand joint compound smooth and feather edge. D. Avoid heavy sanding of adjacent gypsum board surfaces, which will raise nap of paper covering. E. Do not apply putty, patching pencils, caulking, or masking tape to gypsum board surfaces to be painted. F. Lightly scuff-sand tape joints after priming to remove raised paper nap. Do not sand through primer. 3.8 APPLICATION A. Apply coatings in accordance with manufacturer's instructions. B. Mix and thin coatings, including multi-component materials, in accordance with manufacturer s instructions. C. Keep containers closed when not in use to avoid contamination. D. Do not use mixed coatings beyond pot life limits. E. Use application equipment, tools, pressure settings, and techniques in accordance with manufacturer s instructions. F. Uniformly apply coatings at spreading rate required to achieve specified DFT. G. Apply coatings to be free of film characteristics or defects that would adversely affect performance or appearance of coating systems. H. Stripe paint with brush critical locations on steel such as welds, corners, and edges using specified primer. 3.9 REPAIR High Performance Coatings Field Applied 09960-8

- 9 - A. Materials and Surfaces Not Scheduled To Be Coated: Repair or replace damaged materials and surfaces not scheduled to be coated. B. Damaged Coatings: Touch-up or repair damaged coatings. Touch-up of minor damage shall be acceptable where result is not visibly different from adjacent surfaces. Recoat entire surface where touch-up result is visibly different, either in sheen, texture, or color. C. Coating Defects: Repair in accordance with manufacturer s instructions coatings that exhibit film characteristics or defects that would adversely affect performance or appearance of coating systems. 3.11 CLEANING A. Remove temporary coverings and protection of surrounding areas and surfaces. 3.12 PROTECTION OF COATING SYSTEMS A. Protect surfaces of coating systems from damage during construction. END OF SECTION High Performance Coatings Field Applied 09960-9