High voltage for apparatus under Safe Access Rules and statutory regulations is defined as being greater than 1000V ac or 1500V dc.

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

Fixed Electrical Testing

Specification for the Installation of Low Voltage Internal Mains and Services

Installation Address. Postcode. Purpose of the report This form to be used only for reporting on the condition of an existing installation.

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

Control of Equipment on Masts, Towers and Rooftops BOP018.8

QUALIFICATION HANDBOOK

Detailed Requirements Document (DRD) Level 3 OLE Context Core and Specialisms

Supervision of Persons who are not Limited Certificate Holders

PORT OF SAN FRANCISCO ELECTRICAL CODE. Based on the 2016 California Electrical Code

MEMORANDUM TO COMMUNITIES AND LOCAL GOVERNMENT SELECT COMMITTEE ON PART P OF BUILDING REGULATIONS

RIS RIS-1800-ENE. Rail Industry Standard for Network and Depot Interface Management Isolation Documentation. Rail Industry Standard

The Legal Obligations of Employers to Maintain all Portable Electric Equipment in a Safe Condition

Route to Authorisation

UNIVERSITY OF ROEHAMPTON LONE WORKING POLICY

Guidance on Independent Assessment. Rail Industry Guidance Note. Published by: RSSB Block 2 Angel Square 1 Torrens Street London EC1V 1NY

Guidance for Airport Operators Designating Known Suppliers of Airport Supplies

C&G 2382 BS7671: th Edition IEE Wiring Regulations. 25 Questions

QUALIFICATION SPECIFICATION

AS/NZS 3012:2003 AS/NZS

ELECTRICITY at WORK REGULATIONS

GEK B Instructions. Test Cabinet. for Power/Vac Vacuum Circuit Breakers

WHS Management Plans

Integrated Safety, Quality and Environmental Management System WHS AS/NZS 4801 QUALITY AS/NZS ISO 9001 ENVIRONMENT AS/NZS ISO 14001

How to Become an Accredited Service Provider (ASP) Andrew Loukopoulos

ELECTRICAL BULLETIN

ESTATES DEPARTMENT Health & Safety Manager

Verify Category A Audit Content

CHAS Health & Safety Training Requirements July 2017

DOMESTIC ELECTRICAL INSTALLATION PERIODIC INSPECTION REPORT (FOR A SINGLE DWELLING) B ADDRESS AND DETAILS OF THE INSTALLATION Address: SPECIMEN

Guidance on the Application. of ISO / IEC Accreditation International Association for Certifying Bodies

GE/GN8640. Risk Evaluation and Assessment. Guidance on Planning an Application of the Common Safety Method on. Rail Industry Guidance Note

ABBE Level 3 NVQ Diploma in Site Inspection (QCF) Qualification Handbook

SEMEMI SQA Unit Code H2AT 04 Carrying out scheduled maintenance tasks on electrical equipment

Hazardous. Scheme. the power behind your business

Client Requirements to make Particular Safety & Health Appointments

Quality Assurance Manual

Procedure UE PR Access to the United Energy Electricity Network. Document UE PR 0001

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

WORK PLACEMENT INFORMATION BOOKLET

Volunteer Placement Scheme Policy

FPIC2023A Trim and crosscut felled trees

ANGLE GRINDER USE PROCEDURE

IMI ACCREDITATION DIGITAL AUDIO BROADCASTING (DAB)

BIIAB Level 1 Certificate in Business Administration

Site Safety Plus. Site Management Safety Training Scheme (SMSTS) Course appendix G

DISTRIBUTION, OPERATION and MAINTENANCE STRATEGY WORK PROCEDURE

IOSH Electrical Safety in the Food industry Case study: LV Electrical safety rules. Jackie Wooldridge Governance H&S Adviser 18th Nov 2010

Want construction work done safely?

Recruitment and Appointment Policy Responsible Officer. Executive Director, Human Resources Approved by

This Network Rail code of practice contains colour-coding according to the following Red Amber Green classification.

Level 3 Principles, Practices and Legislation for the Periodic Inspection, Testing and Condition Reporting of Electrical Installations.

The Canadian Electrical Code (Saskatchewan Amendments) Regulations, 1999

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

Quality and Environmental Business Process Manual

Inspection and Testing Plan

LANTRA. Highways Sector Scheme 12D SKILLS. TRAINING CENTRE

ISO 9001:2015 ISO 14001:2015 OHSAS

Management of health and safety is very important to us and given the appropriate priority.

St Edward s Church of England Primary School. Work Experience Policy

Business Management Assignment General assessment information

OPITO APPROVED STANDARD. LOLER Competent Person. Competence Assessment Standard

CHAS Assessment Standards

NEBOSH International Technical Certificate in Oil & Gas Operational Safety

PROBUILD GUIDE SUBCONTRACTOR QUALITY MANAGEMENT. Section Two Project Specific Quality Management Plans. Version No 1.

STANDARDS ORGANISATION OF NIGERIA

Level 3 NVQ Diplomas in Electrotechnical Technology (2357)

Community & Client Services. Health & Regulatory Services

Construction (Design and Management) Safety Guidance Document

UPS Electrical Design and. Installation. critica POWER SUPPLIES

Apply Occupational Health and Safety regulations, codes and practices in the workplace

Level 3 Certificate for Traffic Office ( )

Safety Statement Including Risk Assessment

IUU Regulation guidance note

Supervision Guideline for Electrician to Lineworker Apprentices

Permits and authorisations

SEMPEO SQA Unit Code FP3G 04 Forming and assembling electrical cable enclosure and support systems

QUALIFICATION HANDBOOK

COMPETENT PERSON SCHEME SCHEME HANDBOOK

COSVR641 Conform to general workplace health, safety and welfare

Terms and conditions for laboratories appointed to undertake the testing of compost under the Compost Certification Scheme aligned to PAS 100 and the

NC State University OESAD GUIDELINES Contract Year

Level 2 Certificate in Warehousing and Storage Skills (QCF)

COSVR705 - SQA Unit Code H6AP 04 Allocate and monitor the use of plant, equipment or machinery

1. Overview. 2. Benefits. 3. Roles and Responsibilities. 3.1 Student

INSTALLATION INSTRUCTIONS

Casework Technical Support (Social Welfare - Project Management)

Quality Control and Quality Assurance for Installation of Steel Deck

Basic Service. This Section provides information regarding a. Introduction

Supervision of Trainees Holding a Limited Certificate

UKCP media pack. Advertise in The Psychotherapist. About the UK Council for Psychotherapy

Construction Skills Certification Scheme

COMPANY ENVIRONMENT HEALTH and SAFETY POLICY

BHC-P-03.1 Training, Competence and Induction

Transcription:

Electrical Method Statement Guidance Note 8 1

Electrical Method Statement - A Basic Guide to preparation Introduction This Guidance Note gives practical information about creating a method statement. A completed sample template has been included in Appendix 1 and a blank template in Appendix 2. If you wish to use the template in Appendix 2 to construct your own documents, you must ensure that all references to Alcumus SafeContractor Accreditation have been removed and the final documents are clearly incorporated into your existing safety management system. A method statement is an ideal way of recording the hazards involved in a specific work activity and communicating the risk and precautions required to all those involved in the work, including those undertaking the work and their immediate managers. A method statement should be developed in conjunction with a risk assessment and together these demonstrate a safe system of work. The method statement needs be clear, no longer than necessary, and not over complicated. The document should avoid ambiguities or generalisations, which could lead to confusion, and layout a step-by-step sequence of work to describe how the activity is to be carried out safely. Format The actual format is dependent on the work being undertaken and the organisational arrangements in place but generally the following headings should be present: Organisation/company in control of the operation Named individual responsible for the activity and its safety Name of method statement originator and authorisation date Arrangements for changing/deviating from method statement General description of activity Location of activity including access and restrictions General working environment considerations, e.g. temperature and wind speed Protection of others, e.g. members of the public Emergency procedures, including location of emergency equipment Identity of operatives (and any specific training or certification required) Requirements for Personal Protective Equipment Plant and equipment used, including safety precautions and restrictions Materials information e.g. hazard information and storage/transport requirements Work sequence, including associated risks and required control measures for each stage Safety checks/clearances at specific stages Final clearance that activity is completed to specification 2

Any other additional information that may be relevant. The list above is not exhaustive and a method statement may or may not include each and every item. However, as a minimum it must achieve the following objectives: It should be up to date, identifiable and its source accountable. It should contain the sequence of works. It should identify the associated risks and control measures. It should state actions/authorisation required to deviate from method statement. Appendix 1 is a sample method statement for electrical works. It can be as simple or as detailed as the job/risk requires, so long as it meets the four main objectives. 3

Appendix 1 Electrical Method Statement Contract Manager: Joe Bloggs Site Supervisor: David Jones Originator: Joe Bloggs Position: Contracts Manager Date: 01/07/2016 Strict adherence to this method statement is critical to the health and safety of all engaged in the work. Any deviation must first be authorised by the Site Supervisor. Planned Task/Activity Description: Modifying/Extending/Relocating Existing Lighting Circuits and Points (Single Core Cables in Trunking and Conduit). Location and Access: (attached plan as appropriate) Main Office Area. Working Environment & Restrictions: Open Plan Office. Only Electrical Contractors permitted to be present during operation. Existing sections of ceiling will be removed by others. Protection of others: Work undertaken out of hours. Only contractors and client representative present. Emergency Procedures: Normal site evacuation procedure to apply. Operatives/Competence: C&G Qualified Electricians. Personal Protective Equipment: Safety Footwear, Gloves, Goggles Plant & Equipment: Podium Steps, Cordless Drill. Materials Handling/Storage & Safety Information: All material in manageable individual lengths. 4

Critical Stages: (must be undertaken in correct sequence) 1. On arrival site contact made and site induction undertaken 2. Work area cleared for safe access 3. Final circuit arrangements will be determined as indicated on the installation drawings 4. Obtain Permit to work 5. Circuits to be modified will be identified, isolated from the electrical supply by the turning off the relevant circuit protective devices and fuses removed, danger label fitted and circuit verified dead. 6. Existing luminaries will be unplugged and removed to allow access to ceiling roses as required 7. Ceiling roses will be disconnected and removed 8. All wiring contained within the conduits will be pulled back to the nearest convenient point and left neatly coiled 9. The existing conduit/trunking installation will be amended to suit the new layout as indicated on the installation drawings 10. When the amended conduit installation is complete the cables will be drawn back in 11. Circuits will be rewired/amended as necessary to suit the new layout 12. The complete circuit will be tested in accordance with B.S.7671 17 TH Edition I.E.E. Wiring Regulations prior to connection. 13. Accessories/equipment will be second fixed. Luminaires will be replaced and repositioned/new luminaries will be installed. 14. When all accessories are fitted and it is safe to do so the circuits will be re-energised and danger label removed 15. Final live tests will be carried out 16. Site will be cleared and equipment replaced. 17. Site contact notified of work finished. 18. Cancel permit to work Final Clearance: (Work/Activity completed to satisfaction). Name Position: Date: 5

Appendix 2 Blank Method Statement Template Contract Manager: Site Supervisor: Originator: Position: Date: Strict adherence to this method statement is critical to the health and safety of all engaged in the work. Any deviation must first be authorised by the Site Supervisor. Planned Task/Activity Description: Location and Access: (attached plan as appropriate) Working Environment & Restrictions: Protection of others: Emergency Procedures: Operatives/Competence: Personal Protective Equipment: Plant & Equipment: Materials Handling/Storage & Safety Information: Critical Stages: (must be undertaken in correct sequence) Final Clearance: (Work/Activity completed to satisfaction). Name Position: Date: 6

Copyright Alcumus SafeContractor 2016 This publication may be freely reproduced, except for advertising, endorsement or commercial purposes. 7