PROPOSED CONSTRUCTION BUILDING CODES FOR TURF AND LANDSCAPE IRRIGATION SYSTEMS

Similar documents
Broward County Amendments 2004 Florida Building Code Plumbing / Appendix F. Broward County Edition Loose-leaf Supplement. Plumbing Insert New Pages

APPENDIX F PROPOSED CONSTRUCTION BUILDING CODES FOR TURF AND LANDSCAPE IRRIGATION SYSTEMS TABLE OF CONTENTS

Glossary Irrigation Terminology

SECTION POLYVINYL CHLORIDE (PVC) WATERLINE

STANDARDS FOR LANDSCAPE IRRIGATION SYSTEMS JANUARY 2008 EDITION

CURRENT NORTH LAS VEGAS ADDENDA

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

December Illinois American Water Cross Connection Control Program

SECTION EXCAVATING, BACKFILLING, AND COMPACTION FOR UTILITIES

President, Florida Chapter

1. B16.1 Cast Iron Pipe Flanges and Flanged Fittings, Class C 111 Rubber Gasket Joints for Ductile Iron Pressure Pipe and Fittings

Amendment to OPSS 493 (Nov 2015) Construction Specification for Temporary Potable Water Supply Services

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS

2. A preconstruction meeting with the TWA s staff is required prior to initiating construction.

SECTION TRENCHING & BACKFILLING

4A General Information A. Concept... 1 B. Conditions... 1

GRAY WATER SYSTEMS (Reference California Plumbing Code Chapter 16 and 16A) Revised: 6/11/14

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

DIVISION 32 EXTERIOR IMPROVEMENTS IRRIGATION

Questions & Responses RFP No Design-Build Services, Twin Brooks Golf Course Renovations

PHILADELPHIA GAS WORKS SPECIFICATION BOOK For Common Trenching For Natural Gas Mains and Services

***************************************************************************************************************

SECTION UNCLASSIFIED EXCAVATION AND GRADING

This is only a general checklist; please refer to the CVWD Development Design Manual (DDM) for all requirements and regulations.

BAYFILTER SPECIFICATIONS

SECTION 3.0 SPECIFICATIONS FOR DRINKING WATER DISTRIBUTION SYSTEMS DESIGN

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

SEPTIC TANK CONSTRUCTION GUIDELINES

Rural Servicing Guidelines

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

SECTION 8 WATER SUPPLY SYSTEMS

C. Foundation stabilization for pipe and utility structures.

B. Subsurface data is available from the Owner. Contractor is urged to carefully analyze the site conditions.

C900/RJ. CertainTeed. PVC Pipe. with CertainTeed s proven Certa-Lok restrained joint system. Directional Drilling

Residential Sewer Backup Prevention Program

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING)

SECTION FACILITY SANITARY SEWERS

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

GRAY WATER RECYCLING SYSTEMS

SEGMENTAL BLOCK RETAINING WALLS. Comply with Division 1 - General Provisions and Covenants, as well as the following:

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION 820 PUMP STATION DEMOLITION AND SITE RESTORATION

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

SYNTHETIC GRASS INDOOR SURFACE SPECIFICATIONS: K9GRASS LITE

MATERIAL ALLOWANCES AND UNIT PRICES

Gainesville Technical Center 5399 Wellington Branch Drive Gainesville VA Phone (703)

SPECIFICATION : BORING AND JACKING

GENERAL CONSTRUCTION

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

S T A N D A R D. ANSI/ASAE S376.2 JAN1998 (R2004) Design, Installation and Performance of Underground, Thermoplastic Irrigation Pipelines

SECTION IV. PIPELINE EXCAVATION AND BACKFILL

***************************************************************************************************************

Landscape Services QA/QC Manual Sample Selected pages (not a complete plan)

Underground Piping for Private Hydrants & Sprinkler Supply Line

SANITARY SEWER CHEMICAL GROUTING

SECTION LANDSCAPE IRRIGATION

UNIFORM DESIGN AND CONSTRUCTION STANDARDS FOR EXTENDING WATER DISTRIBUTION SYSTEMS SECTION 2 DESIGN STANDARDS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

JACKSON COUNTY WATER AND SEWERAGE AUTHORITY. Cross-Connection Control Program

SECTION FOUNTAINS

DGR PROJECT NUMBER:

GUIDELINES FOR SEPTIC SYSTEM DESIGN

Push Fit Drain, Waste and Vent (DWV) Fittings

SECTION GRAVITY IRRIGATION PIPELINES RUBBER GASKETED REINFORCED CONCRETE PIPE (RGRCP)

Basic Irrigation Design

DIVISION 33 - UTILITIES SECTION UTILITY PIPE BORING AND JACKING DIVISION 33 UTILITIES SECTION UTILITY PIPE BORING AND JACKING

SECTION WATER MAINS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

SECTION HIGH DENSITY POLYETHYLENE PIPE

Cross-Connection Control Program

RESIDENTIAL FIRE SERVICE METERS Addendum #1

Division II Contractors

FLORIDA ARMY NATIONAL GUARD PALM COAST READINESS CENTER 3A3.1 FLAGLER COUNTY, FLORIDA AIRPORT EXECUTIVE DRIVE. scale: scale: CFMO NO.

Fabrication and Installation Table of Contents

Anchorplex retaining wall construction guide. Building. Anchorplex. Retaining Wall Systems

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

2013 R-1 Building Permit Package For Additions, Decks, Fences & Garages

CITY OF CHINO HILLS. Request for Proposals (RFP) for On-Call and Emergency Repair Services Including Water and Sewer Systems

IRRIGATION DESIGN & MAINTENANCE FOR MAXIMUM EFFCIENCY

Minimum Guidelines for the Design and Use of Underpins When Performing Foundation Stabilization and/or Supplementation UP-08

Specifications for Electrical Underground Residential Distribution Systems

Chapter 7 BUILDINGS ARTICLE I. ADMINISTRATION. Decisions of the Building Board of Appeals. ARTICLE II. ADMINISTRATION ARTICLE III.

DESIGN STANDARDS. Division 02 Existing Conditions- Site Work. General

TYPICAL INSTALLATION INSTRUCTIONS

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

SECTION A1 EXCAVATION AND BACKFILL GENERAL

Wastewater Capital Projects Management Standard Construction Specification

CROSS-CONNECTION CONTROL PROGRAM OLD TOWN WATER DISTRICT OLD TOWN, MAINE

SPECIFICATIONS - DETAILED PROVISIONS Section Welded Steel Tanks for Water Storage C O N T E N T S

SEWER SYSTEM DESIGN GUIDELINES

PART VII - WATER SYSTEM DESIGN CRITERIA

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

SECTION CAST-IN-PLACE CONCRETE

PIPE BURSTING GRAVITY SEWER MAINS WITH HDPE PIPE

Innovation in Joint Restraint Systems for PVC Pressure Pipe and Fittings. Clean & Safe Drinking Water Workshop. Wednesday, March 25, 2015

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

Part 4: Irrigation. Contents General Conditions Execution Materials...3

U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Plastic Pipe

Transcription:

APPENDIX F Adopted: March 15, 2012 Effective: March 15, 2012 PROPOSED CONSTRUCTION BUILDING CODES FOR TURF AND LANDSCAPE IRRIGATION SYSTEMS PART 1: GENERAL A. Description. 1. Purpose. To establish uniform minimum standards and requirements for the design and installation of safe, cost effective, reliable irrigation systems for turf and landscape areas which promote the efficient use and protection of water and other natural resources. 2. Definition. Turf and landscape irrigation systems apply water by means of permanent above-ground or subsurface sprinkler or microsprinkler equipment under pressure. 3. Scope. These construction codes shall apply to all irrigation systems used on residential and commercial landscape areas. They address the design requirements, water quality, materials, installation, inspection, and testing for such systems. These construction codes do not apply to irrigation systems for golf courses, nurseries, greenhouses, or agricultural productions systems. 4. Application. All new irrigation systems and any new work to existing irrigation systems shall conform to the requirements of this code. 5. Application to existing irrigation installations. Nothing contained in this code shall be deemed to require any irrigation system or part thereof, which existed prior to the establishment of this code, to be changed altered or modified to meet the standards of this code. B. Permits. 1. Permits required. It shall be unlawful to construct, enlarge, alter, modify, repair, or move any irrigation system or part thereof, or to install or alter any equipment for which provision is made or the installation of which is regulated by this code without first having filed application and obtained a permit therefore from the building official. A permit shall be deemed issued when signed by the building official and impressed with the seal of the governmental agency issuing said permit. 2. Exceptions. All work where exempt from permit shall still be required to comply with the code. No permit shall be required for general maintenance or repairs which do not change the structure or alter the system and the value of which does not exceed $600.00 in labor and material based on invoice value. C. Preconstruction submittals. 1. Plans or drawings. a. Single-family residence. Provide design drawings or shop drawings, where required, for the installation prior to start of construction. Design drawings shall be clearly readable, to reasonable scale, show the entire site to be irrigated, and include all improvements. Drawings can be prepared by a properly licensed qualified contractor. b. Commercial, industrial, municipal and multiplefamily. Provide professionally designed drawings prior to start of construction. Design drawings shall be clearly readable, to reasonable scale, show the entire site to be irrigated, including all improvements, and shall include but not be limited to: date, scale, revisions, legend, specifications which list all aspects of equipment and assembly thereof, water source, water meter and/or point of connection, backflow prevention devices, pump station size, pump station location, design operating pressure and flow rate per zone, locations of pipe, controllers, valves, sprinklers, sleeves, gate valves, etc. The plans and specifications shall be prepared in accordance with Section 106 of the Florida Building Code, Building. c. Sprinkler layout. Sprinkler layout may be modified to adjust for field conditions provided it complies with part VI, Section B, subsection 1 Sprinkler layout and spacing. Prior to final inspection, the contractor shall submit a letter or as-built drawing that reflects the modification to the authority with jurisdiction. D. Definitions. ABS Pipe. Acrylonitrile-butadiene-styrene black, semi-rigid, plastic pipe extruded to IPS. ABS pipe is in limited use in present day irrigation systems. Solvent weld fittings are used with this pipe (see ASTM D 1788). Air Release Valve. A valve which will automatically release to the atmosphere accumulated small pockets of air from a pressurized pipeline. A small orifice is used to release air at low flow rates. Air release valves are normally required at all summits of mainline and submain pipelines in an irrigation system. Anti-Siphon Device. A safety device used to prevent backflow of irrigation water to the water source by back-siphonage. Application Rate. The average rate at which water is applied by an irrigation system, sometimes also called precipitation rate. Units are typically inches/hr or mm/hr. Arc. The angle of coverage of a sprinkler in degrees from one side of throw to the other. A 90-degree arc would be a quartercircle sprinkler. Atmospheric Vacuum Breaker. An anti-siphon device which uses a floating seat to direct water flow. Water draining back from irrigation lines is directed to the atmosphere to protect the potable water supply. Automatic Control Valve. A valve in a sprinkler system which is activated by an automatic controller by way of hydraulic or electrical control lines and controls a single device or multiple devices. 2010 FLORIDA BUILDING CODE PLUMBING F.1

fittings Adopted: March 15, 2012 Effective: March 15, 2012

Adopted: March 15, 2012 Effective: March 15, 2012 FOR ALL AREAS EXCEPT VEHICLE TRAFFIC: Pipe Diameter Minimum depth of Cover ½ through 1 ½ 6 2 through 3 12 4 through 6 18 More than 6 24 VEHICLE TRAFFIC AREAS SHALL REQUIRE A MINIMUM DEPTH OF COVER OF 18. MINIMUM Depth of Cover (inches) Thrust blocks, or other approved method must be used an all gasketed PVC systems. They must be formed against a solid, hand-excavated trench wall undamaged by mechanical equipment. They shall be constructed of concrete, and the space between the pipe and trench shall be filled to the height of the outside diameter of the pipe. Size thrustblocks in accordance with ASAE S-376.1 Material the initial backfill material to 6 above the top of the pipe shall be free from rocks or stones larger than 1-inch in diameter. The final backfill material shall be free of rock or debris that is greater than 3 in diameter. At the time of placement, the moisture content of the material shall F.7

, or when position of irrigation pipes or wires conflict with pipes or appurtenances of other trades. Use pipe sleeves two pipe sizes larger than the carrier pipe or twice the diameter of the wire bundle to be placed under the paving or roadway and extending a minimum of 3 feet beyond the paved area or as required by the Florida Department of Transportation (FDOT).Use sleeve pipe with wall thickness at least equal to the thickness of schedule 40 or PR 160 pipe, whichever is thicker. Proper backfill and compaction procedures should be followed. Adopted: March 15, 2012 Effective: March 15, 2012

Adopted: March 15, 2012 Effective: March 15, 2012 3. Open Trench Inspection: The trench at all joints and iiiiievery transition in pipe size, will be open where iiiiiopen trench inspection is required.