Energy consumption and thermal comfort in a passive house built in Romania

Similar documents
Apartment building Sodastraße 40 in Ludwigshafen, DE

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

Passive House Project documentation

Single family house in Herselt BE

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 31 May Aberdare, Rhondda Cynon Taff, Wales

Swedish development of Energy-efficient buildings

Learnings from residential PH design and procurement in Australia. Luc Plowman

Passive Houses Worlswide: International Developments

Thermal insulation of buildings and cooling demand

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

SAVE THE ENVIRONMENT BY BUILDING ECOLOGICAL PASSIVE HOUSES

2000 Antwerp, terraced house

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

Passivhaus Project Documentation Wrexham Passivhaus

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

Row House Henz-Noirfalise in Eupen, Belgium

Computational and the real energy performance of a single-family residential building in Poland an attempt to compare: a case study

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

Renovation of the Brogården area to Passive Houses

Sapporo Net-Zero Energy Home Hokkaido, Japan. Description. Setting. Super E Canadian Member. Super E Japanese Member. Super E Case Study

A STUDY ON DESIGN OPTIMIZATION OF A NEAR NET-ZERO ENERGY HOUSE

Thermal Performance of Retrofitted Envelopes with Internal Insulation: A Comparative Analysis

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

Retrofit of an historical building toward NZEB

Compactness ratio : 1.2. Openings ratio : 26% (thermic envelope / inhabitable area) Smaller is better 1.9 = bad < 0.8 = good

PREFABRICATED STRUCTURAL SYSTEM FOR PASSIVE HOUSES

A prototype architecture for passive and plus energy building in Estonia

SOLAR XXI: A Portuguese Office Building towards Net Zero-Energy Building

INTEGRAL BUILDING AND ENERGY DESIGN OF AN OFFICE BUILDING COMPARISON OF INITIAL DESIGN IDEAS WITH MONITORED RESULTS

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

Assignment 3 Integrated Energy Design

Principles of Green Architecture

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

THE INFLUENCE OF ENVELOPING ON ENERGETIC AND ECOLOGICAL EFFICIENCY OF PASSIVE HOUSES

EnerPHit. Criteria for Residential-Use Refurbished Buildings

ZEMedS: Case studies

Student Modeling Competition

RESEARCH HIGHLIGHT. Design Development of Low-Energy and Affordable Multi-Unit Residential Buildings

THE PASSIVE HOUSE STANDARD

NUMERICAL STUDY ON THERMAL DEPLETION OF THE GROUND AROUND A GEOTHERMAL HEAT PUMP S PROBE

ZEM ds : Case studies

POST OCCUPANCY DESIGN INERVENTION TO IMPROVE COMFORT AND ENERGY PERFORMANCE IN A DESERT HOUSE

Passive Houses for Arctic Climates

Energy Efficient Buildings in Germany An Introduction

Building Design Data

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

Module 3: Simulation and Data Analysis

Bruck an der Mur. Project summary. Energy concept: Background for the renovation reasons

Sustainable Renovation and Redevelopment. Khuong Nguyen - Kirill Volskii - Mariia Smirnova - Paz Gonzalez Group 10

Passivhaus Projects and Benefits

Renovation of a Detached Single-Family House into an Energy Efficient Low Energy House Larsen, Tine Steen; Maagaard, Steffen; Jensen, Rasmus Lund

Passive Houses in South West Europe

Theory versus practice of energy and comfort in 4 low energy houses in Belgium

Methods for Improving Energy Performance of Single-family Buildings in Poland s Climatic Conditions

Zero Energy Building Example in Estonia. Tõnu Mauring

Portuguese Passive House case study: a comparison between monthly and seasonal energy performance methods

A Comparative Study of the Thermal Comfort of Different Building Materials in Sana a

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

Solar Home Design and Thermal Mass

Potential of ventilative cooling in German residential buildings

Catalogue of Learning Targets

Civil Engineering Construction Chapter 5

The Operational and Maintenance Specificity of Heating Systems Depending on the Thermal Inertia of Buildings

Building Code requirements for house insulation

MOISTURE CONDITIONS IN WALLS AND CEILINGS OF A SIMULATED OLDER HOME DURING WINTER

Experimental Assessment of Hygrothermal Performance of Wood Frame Wall System in Suzhou's Lake Tai Climate Zone

Single family semi-detached four-bedroom home in London, England

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

Passive House Object Documentation

LOW-ENERGY HOUSING ESTATE SUNDAYS

Building performance analysis for double skin residential buildings ABSTRACT BACKGROUND. Porooshat Akhgari

WP5.5: Product concepts for high efficiency step by step retrofits

A new approach to the design and construction of the nearly-zero-energy building in Sardinia

ENERGY DEMAND ANALYSIS AND ENERGY LABELLING OF NEW RESIDENTIAL BUILDINGS IN TUSCANY (ITALY)

The Centre for Sustainable Building (ZUB) * A Case Study

Building Concepts for a mid-century energy-neutral society

Energy renovation of an older house

Incorporating bio-based materials into Passivhaus and nzeb designs

Buildings XI Conference Workshop 2: Thermal Mass IV Assessing Thermal and Moisture Control Benefits of PCM Components by Hygrothermal Simulation

Published in: NSB 2014: 10th Nordic Symposium on Building Physics June 2014 Lund, Sweden

THE ENERGY BEHAVIOUR OF THE RESIDENTIAL BUILDING STOCK IN CYPRUS IN VIEW OF THE ENERGY PERFORMANCE OF BUILDINGS DIRECTIVE IMPLEMENTATION

Varennes Net-Zero Library City of Varennes

Extraction and Analysis of Technical Management Factors for Passive Houses in Korea

Update of the Residential and Non-residential Building Stock Renovation Strategy, Slovak Republic

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

A Quality Assurance System for Improvement of Indoor Environment and Energy Use when Retrofitting Residential Houses

THE STRANGE AND SAD STORY OF QATAR S FIRST PASSIVHAUS

Smart Vapor Retarders

SITE MAIN ROUTES AGRICULTURE AGRICULTURE SCHOOLS MASTER PLAN

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

Energy-efficient Buildings (Passive and Nearly Zero-energy Buildings) Introduction

CEILING TILE. Thermal Mass. Passive Cooling. Thermal Comfort

2015 IECC Whole Building Air Leakage Compliance

Exterior Perspective, East End

Breathability of building elements

MODELLING THE ENERGY PERFORMANCE OF NIGHT-TIME VENTILATION USING THE QUASI-STEADY STATE CALCULATION METHOD

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard

Life Cycle Building Energy:

Transcription:

Chapter 3 - High Performance Sustainable Building Solutions Energy consumption and thermal comfort in a passive house built in Romania Cristina Tanasa, Cristian Sabau, Daniel Dan & Valeriu Stoian Polytechnic University of Timisoara, Department of Civil Engineering, Timisoara, Romania cristina.tanasa@hotmail.com ABSTRACT: This paper mainly presents the measured energy consumption and the variation of the comfort parameters of a passive house built in the city of Timisoara, Romania. Energy efficiency of the house and the thermal comfort offered to the occupants is directly connected with the proper design of the building envelope and the good functioning of the heat pump and of all the other equipment. In order to determine the real energy consumption of the building and to keep under observation the climatic comfort parameters and the good functioning of the equipment, the house is under continuous monitoring for over a year now. Thus, the residential building has a complex monitoring system composed of a series of sensors and electric data recorders which measure various parameters and the electrical energy consumption of the house. The monitoring system was installed in the idea of validating that the design of the house in terms of envelope and equipment is close to the passive house standard through both energy consumption and comfort offered to the occupants, regardless of the weather conditions. Currently, we have the monitoring data after more than one year of monitoring. So, the paper focuses on presenting the precedents regarding the annual energy consumption of the house after one year of monitoring, problems encountered with monitoring and data processing and also information about thermal comfort in the house. 1 INTRODUCTION 1.1 General overview on energy efficiency and thermal comfort It is well known that the construction sector is responsible for a high percentage of energy consumption and consequently has a great implication in the depletion of global resources and environmental pollution (Ding 2007). Throughout the entire life-cycle of a building, approximately 80% of the total energy consumption occurs in the usage phase of the building. Therefore, a way of reducing the environmental impacts of a building is improving the energy performance of the building (Kashreen 2009). The European Union published the Energy Performance of Buildings Directive EPBD as a legislation regarding the energy performance of the buildings for the European member states and aims to promote improvements in the energy efficiency of a building. Measures such as increasing the thickness of thermal insulation, use of elements having low heat transfer coefficients for the envelope and usage of renewable or non-conventional resources are the main factors taken into account by architects, engineers, authorities and the society as a whole. Throughout Europe there are many different concepts of energy efficient buildings that are generally known as buildings with a lower energy demand than common buildings. One of these concepts is the passive house concept. In order to achieve the passive house standard, a house must have an annual heating/cooling requirement for at most 15kWh/m 2 /year and a total energy footprint of less than 120kWh/m 2 /year (Feist 2007). A passive house combines high-level comfort with low energy consumption. Passive components like insulation, advantageous orientation, heat recovery, air tight envelope are the key 161

Portugal SB13 - Contribution of Sustainable Building to Meet EU 20-20-20 Targets elements. Thanks to the high level of thermal insulation, heat recovery system and solar gains, a passive house doesn t need to be heated actively to a large extent. The low amount of additional heat which needs to be supplied is frequently realized with heat pumps (Ochs 2011). Careful implementation of details and good planning are crucial in obtaining a building with very low energy for heating. A proper design and execution can lead to a high energy efficient building which consistently provides pleasant indoor and surface temperatures. The passive house concept can be adapted to any climate zone; the general approach is the same. Depending on the climatic conditions, the quality and type of components, materials and equipment may vary. The research into passive houses proves good thermal climate during the winter season due to the additional insulation and air tightness of the building envelope. In Thullner s thesis two different opinions are presented regarding thermal comfort in a passive house in summer season. One of the statements sustains that in summer times the risk of higher indoor air temperatures appears compared to a traditional house. Due to the well-insulated and airtight envelope it is difficult to reduce these excessive temperatures. The second opinion sustains that it is possible to ensure comfortable indoor climate during summer without active cooling by ventilating at night when the outdoor temperature is lower and avoiding penetration of warm air at daytime. Thus, the low indoor temperature is maintained due to the well-insulated and air tighten envelope. The main idea is that high quality indoor thermal comfort can be achieved also during summer if the incoming warm air or overheating due to sun-faced gazed areas are avoided (Thullner 2011). In Romania, passive houses are a relatively new concept. Currently there are five passive houses built in the whole country. This article refers to a passive house located in the city of Timisoara, west side of Romania. From climatic perspective, Romania is situated in an area with a temperate climate with four seasons. The differences between the temperatures in the hot season and the temperatures in the cold season are very high. Therefore, particular attention should be paid to both heating during winter and cooling in summer time. The purpose is to avoid temperature drop in the elements of the envelope during cold season and also to prevent overheating in the hot season. By monitoring the passive house from Timisoara, the energy consumption is measured and temperatures are kept under observation. After a relevant period of monitoring some conclusions can be drawn regarding energy efficiency of the building and the thermal comfort offered to the occupants. 1.2 Characteristics of the passive house built in the city of Timisoara, Romania The monitored passive house built in Romania is part of a duplex and has a usable area of approximately 144 m 2. The house was designed and built so that the construction costs are minimized (Stoian et. al. 2012). Common materials were used, such as reinforced concrete, bricks, wood and polystyrene. The house has a regular shape and a compact volume so it was easy to achieve an air tight envelope and minimize thermal bridges. Opaque elements of the envelope were insulated with expanded polystyrene plates. So, for the walls a polystyrene layer of 300 mm thickness was used. The roofing system is a non-traffic terrace, with a slope of 2%. Due to the very high level of thermal insulation, the heating demand of the house is low and the heat supply is realized with an air-water heat pump. The domestic hot water production will be assisted by solar energy through a solar panel. The presented house uses a ventilation system with heat recovery. Therefore, most of the heat is contained inside the house, preheating the intake air for the ventilation system through underground heat exchangers. In Figure 1 are presented the layers of the roof for the passive house and in Figure 2 is presented the stratification for the foundation and ground floor of the house. As we can notice, these envelope elements are very well-insulated aiming to achieve the passive standard. 162

Chapter 3 - High Performance Sustainable Building Solutions Ballast 50mm Geotextile Bituminous membrane 5mm Sand Cement mortar, slope 2% min. 50mm Polyethilen foil Thermal insulation (Polystyrene expanded) 320mm Vapour barrier Wooden floor 50mm Mineral wool 100mm, between timber beams 150x250mm Steel profiles 60mm Gypsum plaster board 10mm Interior finishing Finishing - 15mm Adeziv - mortar 5mm Hidroinsulation - 2mm Cement mortar 50mm Concrete slab - 100mm Bituminous membrane Thermal insulation (Polystyrene expanded 250mm) Thermal insulation (Polystyrene expanded 150mm) Ballast - Ø16-30 150mm Compacted soil 400mm Foundation soil Figure 1. Layers used for the roof terrace. Figure 2. Layers used for the ground floor. In the design phase of the building the energy demand was assessed using the Passive House Planning Package PHPP in order to see if the residential building is a passive house in the concept stage (Feist et. al. 2007). Evaluating the theoretical energy performance of the building by using the PHPP tool allowed the designer to test different design solutions against a set of criteria. Thus, was obtained a value of 15 kwh /m 2 year for heating and cooling. The results are promising and indicate that the house is properly designed and can achieve the passive house standard. 2 MONITORING THE PASSIVE HOUSE 2.1 Implementation of the monitoring system and measured energy consumption Implementing the monitoring system in the passive house built in Timisoara, represents a practical way of verifying if the design adopted for the studied house leads to the desired and expected results of energy efficiency. The system registers and collects data which is uploaded to a web server where diagrams available for online visualization are created. The components of the monitoring system result from the need to make data available online and the physical measurements that had to be taken. Therefore the system contains a central unit and a number of ambient/energy flow meters. The monitoring system records data from 41 sensors, with the measuring pace set to 1 minute (Sabau et. al. 2013). After more than one year of monitoring there is sufficient recorded data in order to assess the annual energy consumption of the building and thus evaluate its energy performance. The energy consumption of the building is monitored through 4 electric data recorders (Table 1). It is expected that the higher energy consumption to be registered for heating, ventilation and hot water. The energy consumption for household appliances can have large variations which generally depend on the behavior and lifestyle of the occupants and number of household appliances. Table 1.Electrical energy consumption sensors. Recorder ID Electrical energy consumption Unit EL1 House hold W EL2 Lighting W EL3 Heating, ventilation, hot water W EL4 Exterior W In Figure 3 is presented the monthly electrical energy consumption of the building divided by categories of consumers. As we can see, for the winter months is recorded a much higher energy consumption than for the rest of the year. The consumption is much higher due to the heating demand of the house in the months with low temperatures. We can see that during the year the energy consumption for heating, cooling and ventilation vary greatly compared to the other consumptions. 163

Portugal SB13 - Contribution of Sustainable Building to Meet EU 20-20-20 Targets 2500 Energy consumption [Wh/month] 2000 1500 1000 500 0 5 7 9 11 1 3 EL4 EL3 EL2 EL1 05.2012 >04.2013 Figure 3. Monthly electric energy consumption. The total specific energy consumption of the building obtained through monitoring is 45.8 kwh/m 2 year and the specific energy consumption for heating, cooling and ventilation is 19.85 kwh/m 2 year, which is more than calculated with PHPP. From the heating and cooling energy consumption perspective, the discussed house does not subscribe the passive house standard but the difference is slightly small. 2.2 Analysis of the thermal comfort parameters An essential criterion of thermal comfort is the temperature difference between the surface temperature of the envelope element and the temperature inside the room (C107/2005). Some studies present recommended guideline values for thermal comfort and hygienic climate in a residential building. The recommended operative temperature for winter times varies between 20 C and 24 C and for the summer the guideline values are contained between 23 C and 26 C (Thullner 2010). Normally, in case of a passive house, the well-insulated envelope ensures that in the winter months the heat stays in the house, meaning: evenly warm surfaces in the room, uniform and constant indoor climate and no fluctuations in temperature. In Figure 4 and Figure 5 we can observe how the interior temperatures vary in the cold season and in the hot season. 25 30 Temperature [ C] 20 15 10 5 0 12 1 2 2012 >2013 25 20 interior temperature 15 10 exterior 5 temperature 0 Temperature [ C] 6 7 8 2012 >2013 interior temperature exterior temperature Figure 4. Temperatures in winter months Figure 5. Temperatures in summer months. From the charts represented in Figure 4 we can observe that in winter conditions the temperature inside the house is kept at adequate values for thermal comfort. On the other hand, for the summer season we can notice in Figure 5 that the registered temperatures are slightly higher than recommended. After processing the data recorded by the temperature sensors mounted across the wall we managed to obtain the variation of the temperature from exterior to interior. The results for the winter and summer months are presented in Figure 6 and Figure 7. 164

Chapter 3 - High Performance Sustainable Building Solutions Figure 6. Wall temperatures in winter months. Figure 7. Wall temperatures in summer months. By analyzing the graphics for the winter months (Fig. 6) we can see that despite the big difference between the temperatures at the exterior surface of the wall, the temperatures within the wall, starting from the interface between the polystyrene plate and masonry, strive to remain constant. Comparing these temperatures with the interior air temperatures (Fig. 6) we can state that the difference is very small, for about 1 or 2 Celsius degrees. In summer season (Fig. 7) we can notice a slight overheating of the envelope element where the temperatures at the inner surface of the wall tend to values between 25 and 30 Celsius degrees. Figure 8 shows how the interior air temperature varies with the exterior temperature during the monitoring year. Figure 8. Interior and exterior temperature variation during the monitoring year. As we can see in the chart in Figure 8, the interior air temperature, in both warm and cold months, has values which largely comply with the recommended guideline values for thermal comfort and hygienic indoor climate, independent of the exterior temperature. This fact proves effective thermal insulation and also effective building solution chosen for the envelope element. 165

Portugal SB13 - Contribution of Sustainable Building to Meet EU 20-20-20 Targets 3 CONCLUSIONS The research presented in this paper suggests the growing attention and consideration for the need of building energy efficient houses, being passive houses or nearly zero-energy buildings. Although the passive house concept is not widespread in Romania, such a house can easily be built using techniques and materials which are common in the construction industry of the country. Implementing a monitoring system in a low-energy house is essential for validating its energy performance and moreover it can lead to further improvement in energy efficiency. Monitoring of the passive house built in the city of Timisoara, Romania, led to a series of relevant conclusions that might be helpful for further development of such type of houses and improvement of the used techniques, planning and detail. The energy consumption results obtained after one year of monitoring are approximately equal to the estimated consumption in the design phase. As presented earlier in this paper, the registered energy consumption for heating/cooling is 19 kwh /m 2 year, value which is slightly higher than the estimated value of 15 kwh /m 2 year. On the other hand, the total registered energy consumption is 45.8 kwh /m 2 year. This value is far below the value of 66 kwh /m 2 year, calculated in the design phase. The value of the total energy consumption of the house is not entirely relevant for the energy performance of the building because this consumption may vary depending on the lifestyle of the occupants, appliances installed in the house and so on. Currently, the studied passive house does not meet the standard imposed by the Passive House Institute in terms of energy consumption for heating and cooling but is a promising experiment for further development in the field. One of the reasons for higher than expected energy consumption for heating and cooling is the fact that the other apartment of the duplex was not inhabited or heated during the monitoring year. Therefore, heat losses occurred through the wall that separates the two apartments which was not sufficiently insulated. An extremely necessary upgrade of the house is the mounting of shadowing elements for the windows, in other to avoid overheating during the summer. Also, in winter days with very low minimum temperatures, the air water heat pump did not functioned properly, registering higher energy consumption. Nevertheless, the house ensures great thermal comfort achieved through well-insulated envelope elements, qualitative windows and an adequate ventilation system with heat recovery. AKNOWLEDGEMENTS This work was supported by a grant of the Romanian National Authority for Scientific Research, CNDI UEFISCDI; project number PN-II-PT-PCCA-2011-3.2-1214-Contract 74/2012. REFERENCES Ding, G.K.C. 2008. Sustainable construction-the role of environmental assessment tools. Journal of Environmental Management 86: 451-464. Feist, W. et. al. 2007. Passive house Planning Package 2007 - Technical information. Darmstadt: Passive House Institute. Kashreen, M.M., Banfill P.F.G., Menzies G.F. 2009. Life-Cycle Assessment and the Environmental Impact of Buildings: A Review. Journal Sustainability 1: 674-701. Ochs, F. 2011. Monitoring and simulation of a passive house with innovative solar heat pump system. International Energy Agency - Solar, Heating & Cooling (IEA SHC 2011). Sabau, C., Stoian, D. & Dan, D. 2013. Partial results of monitoring in a passive house. Journal of Applied Engineering Sciences 1(16), Issue 1: 107-110. Stoian, D. & Ioana, B. 2012. A Passive House in Western Romania an affordable Passive House. 16th International Passive House Conference 2012, Hannover 4-5 May 2012: 651-652. Thullner, K. 2010. Low-energy buildings in Europe-Standards, criteria and consequences-a study of nine European countries. Lund: Lund Technical University. ***, C107/2005-Normative regarding termo-technic calculation of construction elements of buildings. Bucharest: Ministry of Regional Development and Tourism. ***, EPBD 2010 - Energy Performance of Buildings Directive. Journal of the European Union: 13-35. 166