HID-PV m /I CDM

Similar documents
PROFESSIONAL LED GROW LIGHTS PRODUCT BROCHURE

Retail lighting. MASTERColour CDM Evolution. Pure sparkle, pure savings

LED light engine / OLED LED compact. Umodule STARK SLE GEN2 Mini STARK SLE LES 10 LES 17 Ø10 13,5. PURE (without housing) Ordering data.

Surface-mounted downlights for metal halide lamps and LEDs

DLM EaseSelect Flex G2. Design-in Guide. State of the art integration for downlight solutions

Radiance Angle [ ] Color Temp. [K]

Plug and Play, easy to use downlight solution

LED light engine / OLED LED compact. Umodule STARK SLE GEN2 FOOD STARK SLE 7,2 Ø50 35 Ø23 Ø3,2 LES 23 LES 26 1,65 ±0, ,75 tc/tp Ø23 3,13 22,5

24/11/2008. Product Description Miniature, lightweight, one-piece electronic gear for 20W and 35W CDM Mini and 35W CDM lamps

DLE Intelligent LED High Bay Fixtures

INNOVATIVE LIFE-CYCLE CONCEPTS FOR MEDIUM-VOLTAGE SWITCHGEAR ON BROWN COAL SURFACE MINING DEVICES

TubePoint. Public lighting. Product guide. Versatility meets high performance in long-lasting tunnel lighting

Applications R41 3 I M1 M

Certaflux. LED system. Certaflux DLM ES CL. PHILIPS Certaflux DLM ES CL G1. July, Design-in guide - Philips Certaflux DLM ES CL G1

3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M / 00 B

Kemppi K5 Welding equipment

Technical System Catalogue Modular PDU (PSM)

LSA 53.2 Low Voltage Alternator - 4 pole

ClearFlood LED Sports & Area luminaire. Juan Gonzalez Valdespino Philips Lighting EMEA Oct 2012

LSA Rating Table Low Voltage Alternators - 4 pole

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

COSMOPOLIS. Benefits of White Light. Road and Urban Lighting. Marc Janssens Sr Product Manager HID Turnhout

KEMPPI K5 WELDING EQUIPMENT. Minarc Evo 180 EXTREMELY COMPACT

Nightspot A High performance floodlights for high pressure discharge lamps or with LEDs

Cable junction boxes with intrinsic fire resistance and insulation integrity

Protection classification IP 23

SOMFY SPECIFICATION March 2012 SECTION... ROLLER WINDOW SHADES SOMFY LS 40 MOTOR RANGE. Disclaimer for advice given to architects and engineers

Truss Mini Pendant PENDANT

Applications R49 A N B1 M

Applications R46 K I P0 M

2000 User/ Installer Guide

CertaFluxPLM II Gen1 April. 2014

High Current Thermal Fuse

LED ROTATION BEAM LIGHT

NEW! The perfect switch

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

LSA 42.3 Low Voltage Alternators - 4 pole

Industrial LED lighting

LATEST UPDATES TO TITLE 24 & TITLE 20 AUGUST 2017

Light levels should be appropriate for the task and per the following guide in Part 1 - General.

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

TOTEM. Cogeneration (CHP) Range. TECHNICAL SUBMITTAL TR r2. Highest total efficiency with modulating output and lowest NO X emissions available

POS 108 USER MANUAL V 2.1

80% LED lamps. MASTER LEDspot. MASTER LEDbulb

HiCloud LED High Bay Light. Designed to replace conventional LED High Bay Light and Metal Halide, HPS & Mercury Vapor.

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN

超凡新星科技有限公司 SHENZHEN SUPERNOVA TECHNOLOGY CO., LIMITED. LED floodlight 200W. cob.com Tel: +(86) cob.

LAMPS & TRANSFORMERS TRI-PHOSPHOR FLUORESCENT LAMPS. 1 Jul. 15

HÜLLER-HILLE NBH 170-4

YINGLI SOLAR TWINMAX MODULES Installation and User Manual

ACOM DLE 120V. Low THD. LED Module AC Operating Module. Samsung AC Operating Module is reasonable solution with better uniformity and high reliability

HOBO Plug Load Logger (UX ) Manual

Servo Hydraulic Universal Testing Machine. SHT4000G Series. Configuration

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

FEATURES & SPECIFICATIONS USA

2016 V1 SERAPHIM ECLIPSE PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG

Commercial Rebate Lighting Program Application/Confirmation

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

AC/DC Converter SLH40 Series

Specification of Backlit LED Panel Light

Technical Application Guide for UP-SHINE LED Downlight UP-DL103A-2.5-5W

Quick Installation Guide. MVC-PTZ-23X Indoor/Outdoor 23 PTZ Speed Dome Camera

LUXEON CoB High Uniformity and High Efficiency Array

ProShell Support Profile for AS/RS and Transfer Cars. An Option for Conductix-Wampfler Conductor Rail Systems

7343M/BAC3-ATVA/C5. Lamp

RapID Raw Materials Verification System

GST001 MV/LV TRANSFORMERS LOCAL SECTION CELG D

SkyRack Warehouse Racking LED Light Fixture

THE KENYA POWER AND LIGHTING CO. LTD

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Truss Pendant PENDANT

Good Husband Brand Remote Lighting Lifter

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Ruby Installation Manual

A Brighter Idea Than Fluorescent

FX1 and FX2 LEDGINE LED Flood Light. Learn more about Philips Luminaires at philips.com/luminaires.

DRUM MOTOR 138LS 138.5Ø 0.10kW kW, with steel helical gearbox

Axicon Point-of-sale barcode verifier. Features. ISO/IEC compliant verification. Lightweight and portable. Automatic variable aperture

min. 50min. 65min. PIT / P3 / P4 Ø

FTW 175 Wireless Monitoring System Reference Manual Part Number

PLUS TEMPERATURE CONTROL SYSTEMS FOR THE CHEMICAL, PHARMACEUTICAL AND PLASTICS INDUSTRIES

64C Amplification Block. Instruction Manual

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

I S O. Eco-Smart Energy Recovery Ventilator

SYGT/S530-E2 LAMP. Features. Description. Applications. Device Selection Guide. Choice of various viewing angles

Eco Engineering and Energy Solutions

Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:

Photo Resistive Flame Detectors

20 W Power Resistor, Thick Film Technology, TO-220

Sensor unit MC2 for toxic gases and oxygen with analog output

LED Power factor: 0.9 Colour rendering index: 80 Luminous flux maintenance 80%: 50000h (L80B20) Colour temperature: on request 3000K and 6000K

Toshiba TGT Luminaire: Roadway and Area LED Lighting

VEGA Floodlight and Street Luminaire

UFL Micro Biogas CHPs

CRU & CRUS LED Canopy Fixtures

Fluorescent lamp Bonalux NL-T5 14W/840/G5

Transcription:

- 1 - Philips Lighting Electronics GDC Eindhoven Author: Johan Kokx April 2011

Contents 1. Introduction 3 2. Version management 3 3. Ordering 3 4. Dimensions and mechanical design-in 4 5. Temperature behaviour 4 6. Wiring 5 7. Electro-Magnetic Compatibility 6 8. Factory handling 7 9. Installation / Mounting 7 10. Operating in abnormal conditions 9 11. Advised communication 9 12. Frequently Asked Questions 10 13. For more information 10-2 -

1. Introduction The PrimaVision Mini driver is the smallest HID gear in the market. This breakthrough in technology has been possible by joint development of the driver, lamp and input from OEMs. The PrimaVision Mini 20W HPF will enable you to have a better power factor as with the 20W LPF. This is especially important in applications with a higher number of luminaires The drivers have improved EMI and are thus CISPR-compliant. 2. Version management This is the design-in sheet for the PrimaVision Mini 20-35 /I drivers. Status of the products: Released Previous status: Released 06-04-2011: Update chapter 9; make table with number of drivers per MCB uniform. 13-10-2010: 9137-006-46266 sht-460 2010-10-13 CISPR15 ed.7.2 compliance 30-05-2007: Version 1.0 Final version Draft version 3. Ordering Version 0.1 Technical name: HID-PV m 20 /I CDM HID-PV m PGJ5 20 /I CDM LPF 12NC: 9137 006 46266 9137 006 01666 EAN3: 8727900890600 8711500909824 EOC: 872790089060000 871150090981730 Technical name: HID-PV m 35 /I CDM 12NC: 9137 006 53566 EAN3: 8727900891645 EOC: 872790089164500 Product Qty box/pallet Net weight (kg) Box Dim. LxWxH (mm) Pallet Dim. LxWxH (mm) HID-PV m 20 /I CDM 10/480 0.312 255x245x82 1200x800x550 HID-PV m PGJ5 20 /I 12/1080 0.140 244x193x146 1200x800x880 CDM LPF HID-PV m 35 /I CDM 10/480 0.312 255x245x82 1200x800x550-3 -

4. Dimensions and mechanical design-in HID-PV m PGJ5 20 /I CDM LPF A1 (mm) B1 (mm) C1 (mm) 190.0 43.3 30.0 HID-PV m 20 /I CDM & HID-PV m 35 /I CDM: B1 C1 A1 (mm) A2 (mm) B1 (mm) C1 (mm) D1 (mm) 234.7 225.1 49.4 34.0 4.8 5. Temperature behaviour T case HID-PV m 20 /I CDM and HID-PV m 35 /I CDM The T case -point is the position shown on the drawing below. X - 4 - A2 A1 Tcase test point D1 Y

X Y 110±2 10±2 Dimensions in mm. Lifetime 40k hours/90% survivals: T case max T ambient max HID-PV m 20 /I CDM 80 C 45 C HID-PV m 35 /I CDM 85 C 45 C T case HID-PV m PGJ5 20 /I CDM LPF Lifetime 40k hours/90% survivals: T case max T ambient max HID-PV m PGJ5 20 /I CDM LPF 65 C 40 C Temperature Testing Because the driver will regulate the lamp to a constant power, the input current will increase when the input voltage is lower. This ultimately will influence the power losses, so the worst-case temperature should therefore be measured at lowest mains voltage of 198V. To guarantee, that the maximum value of T case. is not exceeded, a thermo-couple should be mounted on the T c point of the driver. For more information about lifetime and temperature please consult the HID application guide. 6. Wiring The wiring should be connected according the pictures below. This driver is equipped with a safety earth connection and must be connected to the earth connection of the mains-supply. For EMI-reasons, it is important to make the hot lamp-wire (indicated by the.symbol) as short as possible. - 5 -

HID-PV m 20 /I CDM 3.0kV HID-PV m 35 /I CDM 2.0kV HID-PV m PGJ5 20 /I CDM LPF These drivers have a loop-through possibility for the mains-wiring. Connector type: Wire cross section: Strip length Max cable capacitance lamp-wires: Maximum length lamp-wires: 7. Electro-Magnetic Compatibility - 6-1.5kV WAGO type 804; push in contacts 0.75..2.5 mm² solid or stranded 10-11 mm 200 pf 2 meter for cable without earth wire. 1 meter for a cable with earth wire. The driver is tested and approved according CISPR 15 ed. 7.2. However the position of the wiring can negatively influence the EMC behaviour of this HID-system. Therefore it is advised to pay attention to the following: Place the mains-wires in such a way, that they are not in parallel with the lamp-wires. Make the spacing between lamp- and mains-wires as big as possible. Keep the mains-wires close together.

Keep the lamp-wires close together and preferably as short as possible However do not exceed the maximum allowed length of the lamp-wires. 8. Factory handling Traceability For traceability reasons year and week of production, as well as productionlocation, can be found on the product-label. The production-code consists of production year and week. Example: If a product has been marked 0810 : Position 1 and 2 are the last digits from the year of production. The digits 08 indicates that the product has been made in 2008 Position 3 and 4 indicate the week of production. The number 10 indicates that the product has been made in week 10. Furthermore, each product has a serial number, including barcode. (This is depending of the production-location) 9. Installation / Mounting Lamps that can be driven by the driver Driver Lamp HID-PV m PGJ5 20 /I CDM LPF CDM-Tm PGJ5 20W HID-PV m 20 /I CDM All CDM 20W lamps, except Tm PGJ5 HID-PV m 35 /I CDM All CDM 35W lamps, except Tm PGJ5-7 -

DESIGN IN SHEET Suitable application for this drivers This product is designed mainly for luminaires that are working in an Indoor environment (IP23 or superior casing). The PrimaVision Mini range is not intended for Outdoor use due to the following outdoor constraints: High humidity and condensation risks Vibrations e.g. when the luminaire is mounted on a public lighting pole Lightning surges on the mains. Outdoor electronic drivers are 4kV protected but the HID-PV mini drivers are protected up to 2kV. Therefore, it is the responsibility of the luminaire manufacturer and the installer to take into account the above and implement adequate protection for the above. Here are some requirements for Outdoor applications: Place the driver in an IP54 or higher environment Avoid placing the driver or luminaire in high poles Place adequate Lightning protection in the lighting installation Planner should take it into account for Cost of Ownership calculations and maintenance plans. If the above points are not taken into account in the design and the installation, Philips Lighting Electronics will have the option not to apply the standard guarantee. Maximum number of drivers per MCB The maximum number of drivers, which can be connected to a MCB, can be found in the table below: Maximum number of drivers per MCB Driver type B16A B10A C16A C10A HID-PV m PGJ5 20 /I CDM LPF 48 30 81 50 HID-PV m 20 /I CDM 24 15 41 25 HID-PV m 35 /I CDM Relative number of drivers 100% 63% 170% 104% DC-operation This driver is not designed for DC-operation. Mounting The strain-reliefs can be closed by means of (pre-assembled) slotted crosshead screws of the PZ2 type. The maximum allowed torque for mounting the screws is 1.0Nm. There are several methods to install the driver: The driver can be mounted on a solid surface by means of 2 M4 screws. The driver can be placed on the ceiling, without any means to fix it. (It is advised, not to place the driver upside down) A metal hook can be applied to one of the mounting holes of the driver, to hang it on the construction of the ceiling. (it is advised to have the wires/connectors facing down) In all this situations, it is important not to cover the driver by any (isolating) material. - 8 -

DESIGN IN SHEET 10. Operating in abnormal conditions Active Thermal protection If the driver is used at a too high temperature an internal thermal protection will protect the driver against damage; the driver will switch off the lamp. Mains voltage needs to be reset in order to reset thermal protection. The thermal protection of HID-PV m PGJ5 20 /I CDM LPF drivers becomes active at Tcase > 97 C. The thermal protection of HID-PV m 20 /I CDM and HID-PV m 35 /I CDM drivers becomes active at Tcase > 90 C. Mains voltage The driver is designed to operate within a operational/safety range of 180-264V. However the performance is guaranteed within the performance range of 198-254V. Within this range, the lamp power is regulated within ±3% of its nominal power. Under/Over voltage The driver has a limited protection against over voltage, it is advised to prevent higher mains voltages than +10%. This will however negatively influence the lifetime and reliability. The driver will not start if the mains voltage is lower than 160V. Lightning and power surges Protection against surges because of lightning are built in the gear. IEC61547, surge levels: 1.0kV Line to Line and 2.0kV Line to GND End Of Life (EOL) lamp protection The driver has a protection against an End Of Life Lamp. The driver will detect this lamp and switch off. The mains has to be reset in order to reset the driver. Mains dips If mains dips occur that cause the lamp to extinguish, the driver will automatically re-ignite the lamp after a cooling-down period of approximately 10 minutes. The driver will try to re-ignite the driver for maximum 30 minutes. If several mains dips occur in short time, the re-ignite time will be added to this maximum of 30 minutes. After this 30 minutes, the driver will shut-off and the mains needs to be cycled to reset the internal ignition timer in the driver. 11. Advised communication Philips Lighting Electronics advises to communicate the following information to your customers via your preferred media: Catalogues, brochures, Product datasheets, Mounting instructions, Internet and Intranet. Technical Due to lamp characteristics, this driver needs some time to re-ignite (10 15 minutes) after switch off. When the lamp has reached end of life, the driver will switch off the lamp in order to avoid lamp overheating. After lamp replacement, the mains voltage will have to be reset and the system will work normally. The driver does not need to be - 9 -

replaced. The PrimaVision gear range is equipped with an internal thermo-switch that will prevent loss of driver lifetime due to overheating in the luminaire/installation. Check also chapter 9 for relevant technical information Marketing The use of PrimaVision Compact in your luminaire will provide your customer the following benefits: Flicker free operation 30 to 40% longer lamp lifetime 10% energy saving compared to a Electromagnetic system Safe and comfortable behaviour when lamp reaches End of Life Guarantee The guarantee of 3 and 5 years for Philips Electronics is applicable for this product. For more information about guarantee, please visit our website: Http://www.lampsandgear.philips.com/ 12. Frequently Asked Questions Why is there a specific driver for PGJ5 lamps? The properties of the CDM-Tm lamps with PGJ5 lamp-holder differ from the ones with the GU6.5 lamp-holder. Therefore it is not possible to exchange these. Why is the 20W LPF version not potted compared to the other versions? The dissipation of the 20W LPF is significantly lower and therefore no potting material is needed, to transport the temperature to the outside of the driver. The housing is made of plastic. Does this give problems with EMC or temperature? No, the gear is specially developed for the housing. Therefore, no problems with EMC and temperature occur. Can I use this driver in a 24hr-7days installation? No, this driver is not suitable for 24/7 operation. 13. For more information Please contact your local sales representative. Check OEM application guide for general information about electronic gear. Visit our web-site www.philips.com/ehid - 10 -