NZQA registered unit standard version 6 Page 1 of 5

Similar documents
NZQA registered unit standard 9506 version 5 Page 1 of 5. Conduct a sample analysis in a petrochemical laboratory

NZQA registered unit standard 9537 version 5 Page 1 of 6. This unit standard applies to operational activities carried out on producing wellheads.

NZQA registered unit standard version 1 Page 1 of 5. Diagnose and repair faulty electronic equipment to component level

NZQA registered unit standard 9536 version 5 Page 1 of 6. Undertake petrochemical wellhead maintenance activities under supervision

NZQA registered unit standard version 1 Page 1 of 5. Develop, implement and review a HACCP application for a food processing operation

NZQA registered unit standard version 4 Page 1 of 5

NZQA registered unit standard version 4 Page 1 of 5

NZQA registered unit standard version 3 Page 1 of 5

NZQA registered unit standard version 2 Page 1 of 5. Generate chlorine dioxide for wood pulp bleaching

NZQA registered unit standard version 2 Page 1 of 5. Describe the roles and functions of a CIMS Incident Management Team (IMT) at an incident

NZQA registered unit standard version 2 Page 1 of 5. Demonstrate knowledge of safety management systems for an aviation environment

NZQA registered unit standard version 3 Page 1 of 5

NZQA registered unit standard 738 version 5 Page 1 of 7

ELECTRICITY SUPPLY - POWER SYSTEM MAINTENANCE Carry out routine inspection and servicing on high voltage minimum oil circuit breakers

NZQA unit standard version 6 Page 1 of 5. Apply and remove safety measures in an electricity supply environment

This qualification has been revised. The last date to meet the requirements is 31 December 2021.

NZQA registered unit standard version 3 Page 1 of 5

Carry out routine inspection and servicing on high voltage bulk oil circuit breakers

NZQA Expiring unit standard version 2 Page 1 of 5. Install and maintain roofing, rainwater handling, and cladding systems, and flashings

Electrical Protection Methods and Devices SAMPLE. Learner Workbook Version 1. Training and Education Support Industry Skills Unit Meadowbank

SECURITY STAFF SERVICES Demonstrate knowledge of and operate electronic equipment as a security officer

PUBLIC SECTOR SERVICE DELIVERY Establish client needs and gain agreement on requirements for public sector service delivery

PUBLIC SECTOR SERVICE DELIVERY Develop public sector service delivery objectives, and implement systems to meet client needs

NZQA unit standard version 2 Page 1 of 5. Demonstrate understanding of a HACCP application in a food processing operation

NZQA registered unit standard version 1 Page 1 of 7. Plan and fell trees using advanced techniques in a commercial forest harvesting operation

Remove and repair perforated non-structural body panel corrosion damage

NZQA registered unit standard version 1 Page 1 of 7. Fell trees in a commercial forest harvesting operation

Electrical installations Marinas and boats

Supervision of Trainees Holding a Limited Certificate

National Certificate in Forestry (Generic Skills - Workplace Safety and Operations) (Level 2) Level 2

Demonstrate knowledge of servicing automotive air conditioning systems

Set up, repair and maintain a Baader BA 190 fish filleting machine

LEATHER - BOTTOM STOCK, MAKING AND LASTING Clean, dress, and spray footwear in a shoe room

NZQA unit standard version 5 Page 1 of 5. Attach, lift, move, and place loads using mobile plant

ROAD TRANSPORT OPERATIONS Manage the transport of overdimension and overweight loads by road

NZQA registered unit standard version 1 Page 1 of 7

Fixed Electrical Testing

This qualification has been reviewed. The last date to meet the requirements is 31 December 2018.

Supervision of Persons who are not Limited Certificate Holders

FREQUENTLY ASKED QUESTIONS

Level 3 Principles, Practices and Legislation for the Periodic Inspection, Testing and Condition Reporting of Electrical Installations.

UPS Electrical Design and. Installation. critica POWER SUPPLIES

On successful completion of the Unit candidates will be able to carry out a simple earthing exercise on a simulated electrical installation.

Operate a root crop harvester

Transport perishable products by road

Establish quality requirements, manage, and monitor the installation of subdivision infrastructure

Instruct a programme using low ropes course activities

Set up, repair and maintain a Baader BA 212CK fish filleting machine

Level 3 NVQs in Refrigeration and Air Conditioning (6187) Qualification handbook for centres

Level 4. Credits Purpose

IRRIGATION Demonstrate knowledge of irrigation systems, components, and performance

Engineering Design & Power Training Institute

UEENEEP026A Conduct in-service safety testing of electrical cord connected equipment and cord assemblies

This qualification has been reviewed. The last date to meet the requirements is 31 December 2018.

Member Service Electric Wiring Guidelines

Mobile Hot Food Merchandiser Series. Series: MM Operation Manual

PUBLIC SECTOR COMPLIANCE MANAGEMENT Audit quality management systems for compliance with weights and measures legislation

UNIVERSITY OF SHEFFIELD IN-SERVICE INSPECTION AND TESTING OF ELECTRICAL EQUIPMENT POLICY AND GUIDANCE

CONSENT AND MODERATION REQUIREMENTS (CMR) for Plastics Processing Technology

LEATHER - CUTTING AND CLOSING Perform specialist footwear closing operations

POULTRY HATCHERY Process day-old poultry chicks

Five Shades of. Your guide to changes within BS 7671!

Detailed Requirements Document (DRD) Rail Engineering Advanced Technician Level 4 Electrification Knowledge & Skills Content

QUALIFICATION DETAILS

Information Document Protection System Information ID# R

Electricity in underground mines and tunnels

C&G 2382 BS7671: th Edition IEE Wiring Regulations. 25 Questions

VEHICLE BODYWORK Detail and groom a vehicle

Assembling, wiring and testing electrical panels/components mounted in enclosures

Demonstrate an advanced knowledge of railway signals

7. For items classified in Section K as C1 ( Danger

Contents QUALIFICATIONS PACK- OCCUPATIONAL STANDARDS FOR CONSTRUCTION INDUSTRY. Introduction Qualifications Pack Assistant Electrician

DOMESTIC ELECTRICAL INSTALLATION PERIODIC INSPECTION REPORT (FOR A SINGLE DWELLING) B ADDRESS AND DETAILS OF THE INSTALLATION Address: SPECIMEN

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

Introduction. Origin

REFERENCE CP_TSSPEC_103 1 DATE: NOV 2015 PAGE: 1 OF 13 SPECIFICATION FOR SMALL POWER DISTRIBUTION UNITS (READY BOARDS) TABLE OF CONTENTS

AGREEMENT FOR CONNECTION TO [EASTERN /LONDON / SOUTH EASTERN] POWER NETWORKS PLC S DISTRIBUTION SYSTEM

General Electrical Safety Awareness Course: E100

Trainee Assessment Assess risk, develop risk management strategies, and prepare a risk management plan within a health organisation

About this guide 5 Section 1: Meeting VET sector requirements 7

Make ready a sheet-fed offset printing press for spot colour work

Installation Address. Postcode. Purpose of the report This form to be used only for reporting on the condition of an existing installation.

Engineering Recommendation G81 - Part 4: Design and Planning

Level 3 NVQ Diplomas in Electrotechnical Technology (2357) Qualification handbook for centres

National Certificate in Painting with optional strands in Wall Coverings, Spray Techniques, Specialised Coatings, and Industrial Coatings

IMI ACCREDITATION DIGITAL AUDIO BROADCASTING (DAB)

AS/NZS 3010:2005 AS/NZS

US PR-8. Instruction Manual. - approved

ELECTRICITY AT WORK REGULATIONS 1989

FAST SPOTTER WT-FS-5.0

This qualification has been reviewed. The last date to meet the requirements is 31 December 2018.

Australian/New Zealand Standard

Facility Interconnection Requirements

Qualification details

Diode Coupling Negative Output Guide

AS/NZS 3012:2003 AS/NZS

Electrical Networks Principles and Performance

Level 3 NVQ Diplomas in Electrotechnical Technology (2357) Qualification handbook for centres

Centre for Rail Skills. National Occupational Standards. for the. Maintenance and Repair of. Traction and Rolling Stock

Wiring and testing programmable controller based systems

Transcription:

Page 1 of 5 Title Demonstrate knowledge of circuit protection Level 3 Credits 3 Purpose This unit standard is for electricians and related trades who need to understand and select devices for the protection of electrical circuits. People credited with this unit standard are able to: demonstrate knowledge of circuit protection terms and principles; demonstrate knowledge of circuit protection devices; demonstrate knowledge of residual current devices (RCDs); and select circuit protection devices for electrical applications. Classification Electrical Engineering > Electrical Installation and Maintenance Available grade Achieved Explanatory notes 1 This unit standard has been developed for learning and assessment off-job. 2 This unit standard and unit standards 5932, 15848, and 25070 together meet the assessment requirements of ERAC CEPC 5. This unit standard and unit standards 5932, 15848, 17602, 29465, and 29480 together meet the assessment requirements of ERAC CEPC 10. This unit standard and unit standards 5932, 15848, 29443, 29444, and 29480 together meet the assessment requirements of ERAC EPC 12. This unit standard and unit standards 5931, 5932, 29419, 15848, and 29480 together meet the assessment requirements of ERAC CEPC 23. This unit standard and unit standards 5931, 5932, 15848, 29419, 29426, 29430, 29440, 29471, and 29480 together meet the assessment requirements of ERAC CEPC 24. This unit standard and unit standards 5931, 5932, 15848, 29419, 29430, 29440, and 29474 together meet the assessment requirements of ERAC CEPCs and 37. 3 Definitions CEPC Critical Essential Performance Capability. ELCB earth-leakage circuit-breaker. EPC Essential Performance Capability. ERAC Electrical Regulatory Authorities Council. EWRB Electrical Workers Registration Board. GFI ground-fault interrupter. HRC high rupturing current.

Page 2 of 5 Industry practice those practices that competent practitioners within the industry recognise as current industry best practice. PSC prospective short-circuit current. RCBO residual current-operated circuit breaker with overcurrent protection. RCCB residual current-operated circuit breaker. Safe and sound practice as it relates to the installation of electrical equipment is defined in AS/NZS 3000:2007, Electrical Installations (known as the Australian/New Zealand Wiring Rules). 4 a Candidates may refer to current legislation and Standards during assessment. b Demonstration of safe working practices and installation in accordance with safe and sound practice are essential components of assessment of this unit standard. c All activities and evidence presented for all outcomes and evidence requirements in this unit standard must be in accordance with: i legislation; ii policies and procedures; iii ethical codes; iv Standards may include but are not limited to those listed in Schedule 2 of the Electricity (Safety) Regulations 2010; v applicable site, enterprise, and industry practice; and, vi where appropriate, manufacturers instructions, specifications, and data sheets. Outcomes and evidence requirements Outcome 1 Demonstrate knowledge of circuit protection terms and principles. 1.1 Explain the meanings of five circuit protection terms. may include but is not limited to rated current, voltage rating, fusing current (fusing factor, tripping factor), utilisation category, classes of fuses and circuit breakers, cut-off characteristic, time vs current characteristic, category of duty, discrimination, back-up protection, rupturing capacity (breaking capacity), prospective short-circuit current (PSC), coarse excess-current protection, close excess-current protection, sensitivity. 1.2 State the relationship between fusing or tripping current, current rating, and fusing or tripping factor for a protective device. 1.3 Explain the merits of providing close excess-current protection. 1.4 Describe the three effects of electrical faults in terms of the danger to people and property. faults leakage current, over current, short circuit; effects may include but are not limited to electromechanical energy, heat energy, damaged cables and equipment, fire,

Page 3 of 5 explosion, electric shock. 1.5 Explain the need for rapid disconnection of faulty circuits. Outcome 2 Demonstrate knowledge of circuit protection devices. 2.1 Describe protection devices with the aid of diagrams and reference to construction and operating principles. devices rewirable, cartridge and high rupturing capacity (HRC) fuses, miniature circuit-breaker (mcb), magnetic and thermal overload relays, fuses (including miniature glass cartridge type), fusible links. 2.2 Identify two fuse cartridge type and size from physical or graphical representations of cartridge markings. 2.3 Classify protection devices according to their ability to provide either coarse or close excess-current protection. rewirable fuse, HRC fuse, miniature circuit breaker. 2.4 Compare time versus current curves of rewirable fuses, HRC fuses, and miniature circuit breakers in terms of speed of operation and accuracy of calibration. 2.5 Describe three effects of poor selection of protective devices for three different fault conditions. poor selection may include but is not limited to underrated, overrated, incorrect utilisation category, classes of fuses and circuit breakers, fusing or tripping factor, rupturing capacity; fault conditions may include but is not limited to overload, shortcircuit, earth leakage fault, mechanical overload, loss of one phase in a motor, excessive earth leakage. 2.6 Describe a three-phase protective device with reference to construction, operating principle, and protection afforded additional to that of a single-phase circuit. 2.7 Give practical demonstrations of resetting or reloading protective devices. HRC fuse, rewirable fuse, circuit breaker, thermal overload. Outcome 3 Demonstrate knowledge of residual current devices (RCDs).

Page 4 of 5 3.1 Explain RCD terms. residual current-operated circuit breaker (RCCB), residual currentoperated circuit breaker with overcurrent protection (RCBO), portable residual current device (PRCD), socket residual current device (SRCD). 3.2 Describe an RCD with reference to construction and principle of operation. 3.3 Describe procedures for testing RCD and record the operating times. personal protection, property protection, medical area protection, schools. 3.4 Describe precautions to be taken when testing circuits containing RCDs. 3.5 Provide three examples of situations requiring RCD protection. Outcome 4 Select circuit protection devices for electrical applications. 4.1 Select protection device to meet the application requirements in terms of electrical protection characteristic, speed of operation, and reset method. overload, short circuit, locked rotor, phase failure, phase reversal; 4.2 State and compare relative merits of devices where more than one device meets the application requirements. Replacement information This unit standard replaced unit standard 755, unit standard 1207, and unit standard 1708. Planned review date 31 December 2019 Status information and last date for assessment for superseded versions Process Version Date Last Date for Assessment Registration 1 10 February 1999 31 December 2013 Revision 2 3 April 2001 31 December 2013 Review 3 26 May 2005 31 December 2021

Page 5 of 5 Process Version Date Last Date for Assessment Rollover and Revision 4 15 March 2012 31 December 2021 Revision 5 15 January 2014 31 December 2021 Review 6 21 July 2016 N/A Consent and Moderation Requirements (CMR) reference 0003 This CMR can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Please note Providers must be granted consent to assess against standards (accredited) by NZQA, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be granted consent to assess against standards by NZQA before they can register credits from assessment against unit standards. Providers and Industry Training Organisations, which have been granted consent and which are assessing against unit standards must engage with the moderation system that applies to those standards. Requirements for consent to assess and an outline of the moderation system that applies to this standard are outlined in the Consent and Moderation Requirements (CMR). The CMR also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. Comments on this unit standard Please contact at reviewcomments@skills.org.nz if you wish to suggest changes to the content of this unit standard.