Analysis of 14 Trace Elements in Stainless Steel

Similar documents
Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

Explore the future. Automotive Test Systems Process & Environmental Medical Semiconductor Scientific

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode

Composition Analysis of Animal Feed by HR ICP-OES

Excellence in gas analyzers since Over 186 years of Jobin Yvon optical experience. The expertise of HORIBA combustion technology

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

Water Analysis Using ICP-OES with an Ultrasonic Nebulizer

Kunikazu Ide and Yoshisuke Nakamura. 1. Introduction

Analysis of Trace Elements in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo

Method for Estimation of Na 2 O and K 2 O in Ores, Fluxes, Coal and Coke Ash by Inductively Coupled Plasma-Atomic Emission Spectroscopy

Analysis of Trace Metals in Surface and Bottled Water with the Optima 7300 DV ICP-OES

GB Translated English of Chinese Standard: GB

Avio 200 ICP-OES Flat Plate

ABSTRACT. This study investigates the use of inductively coupled plasma-optical emission spectrometry

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

The image part with relationship ID rid4 was not found in the file. Welcome

ANALYTICAL PERFORMANCE OF A HANDHELD EDXRF SPECTROMETER WITH MINIATURE X-RAY TUBE EXCITATION

National Food Safety Standard

High matrix tolerance of the Thermo Scientific icap 7000 Plus Series ICP-OES with the radial Ceramic D-Torch and the sheath gas adaptor

Common Challenges facing Laboratories doing Elemental Analysis Today

The Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

The Determination of Trace Elements in Waters using the US EPA Method and the Thermo Scientific icap 6500 ICP-OES (Duo)

Metals Analyzer. OES 6000 Optical Emission Spectrometer. fast and accurate metal analysis

DRPK-005

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Spectro-photometric determinations of Mn, Fe and Cu in aluminum master alloys

This method is applicable to the following parameters: Nitric Hydrochloric acid digestion, Instrumental analysis.

Analysis of Cast Iron Using Shimadzu PDA-7000

High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

Analysis of an OTC Multivitamin Tablet Using X-ray Fluorescence Spectroscopy and Atomic Absorption Spectroscopy

Strong Acid Leachable Metals (SALM) in Soil - Prescriptive

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

R = kc Eqn 5.1. R = k C Eqn 5.2. R = kc + B Eqn 5.3

ISO INTERNATIONAL STANDARD. Paper, board and pulps Determination of total magnesium, total calcium, total manganese, total iron and total copper

NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA (Zhenghua Renmin Gongheguo Guojia Biaozhun)

Certificate of Analysis

New Advances using Handheld XRF Technology for the Prevention of Flow-Accelerated Corrosion (FAC)

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

Optical Emission Spectrometers

Simple, fast and reliable analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Effect of Precipitation Hardening on Microstructural Characteristics of 15-5 Ph Steel

ISO INTERNATIONAL STANDARD

ATI FLAT ROLLED PRODUCTS Brackenridge, PA for technical competence in the field of

ANALYTICAL REFERENCE MATERIALS INTERNATIONAL Part of LGC Standards 3 Perimeter Road, Unit 9 Manchester, NH USA

USEPA 1,2 Bicinchoninate Method 3 Method 8506 (CuVer 1) and Method 8026 (CuVer 2) 0.04 to 5.00 mg/l Cu Powder Pillows or AccuVac Ampuls

Assaying and Analysis Choices in Practice

TITLE: Surface Decontamination of Zinc Compounds (Elemental Zinc Powder (Zn), Zinc Oxide (ZnO), and Zinc Acetate (Zn(O 2 CCH 3 ) 2 ) by DeconGel TM

SPECTRO XRF Report. SPECTRO xsortxhh03. Analysis of Solid Metal Samples. Summary

Scope and application: For water, wastewater, seawater, brine solutions, produced waters and hydraulic fracturing waters.

STUDY OF ELEMENT FINGERPRINTING IN GOLD DORÉ BY GLOW DISCHARGE MASS SPECTROMETRY

The Many Facets and Complexities of 316L and the Effect on Properties

Analysis of elemental impurities in drug products using the Thermo Scientific icap 7600 ICP-OES Duo

Methods for determination of mercury in LP gas

Thin-Layer Chromatography of Aluminium: Quantitative Densitometric Determination of Fe 2+, Ni 2+, Cu 2+, and Si 4+

XRF DRIFT MONITORS DATA CALIBRATION MATERIAL

ENGINEERING MATERIALS 65 Granada Drive Pagosa Springs, CO

Rev Experiment 10

X-ray Fluorescence Spectrometry X-ray Fluorescence Spectrometry (XRF) is a non-destructive, quantitative technique for determining chemical

Korkealämpötilaprosessit

METHODS OF ANALYSIS BY THE U.S. GEOLOGICAL SURVEY NATIONAL WATER QUALITY LABORATORY-- DETERMINATION OF CHROMIUM IN WATER BY GRAPHITE

ICP Expert software. Technical Overview. Introduction

Review on Agriculture and Rural Development vol. 2. (1) ISSN

Determination of Elemental Bad Actors (As, Hg and Si) in Petrochemical Samples Using ICP-AES and ICP-MS

Determination of Iron Content in Different Hemoglobin Samples from Some Patients by UV-Visible Spectrophotometer

SPECTROPHOTOMETRIC DETERMINATION OF IRON

Recovery of Cu, Zn, Ni and Cr from Plating Sludge by Combined Sulfidation and Oxidation Treatment

Recovery of Cu, Zn, Ni and Cr from Plating Sludge by Combined Sulfidation and Oxidation Treatment

FluoroMax Series. Sensitive, flexible, easy-to-use fluorometers. Powerful technology with bench-top convenience

OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS. Shane Jordan-Hill. Merck Millipore

SPECTRAL INTERFERENCE IN X-RAY FLUORESCENCE ANALYSIS OF COMMON MATERIALS

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

Polyvidone Polyvinylpyrrolidone H 2 C H C N

Thermo Scientific icap 6000 Series ICP Emission Spectrometer

New Developments in Measuring Low Silicon in Process Piping Using Handheld X-ray Fluorescence (XRF)

Oxygen Demand, Chemical

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

SUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 000

Photochemical studies of Eichhornia crassipes (Water Hyacinth)

Terephthalonitrile-derived nitrogen-rich networks for high

Monitoring and fractionation of

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Application Notes for COD Analysis DETERMINATION OF CHEMICAL OXYGEN DEMAND (COD) IN WATER AND WASTE WATER.

Method of determination of phthalates by gas chromatography / mass spectrometry in wines

Argon Plasma Sustained in Different Discharge Configurations

Magnetic drive pumps YMD series

Standard Operation Procedure. Analysis of Major, Minor and Trace Elements in Soil and Sediment Samples with ICP-OES and ICP-MS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Additive Manufacturing Powder AMPO - POWDER FOR THE WORLD S TOP PERFORMERS. Additive Manufacturing Powder

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline

Effects of cigarette butts on coastal waters: an elemental analysis of seawater from St. Simon s Island

Accuracy and Precision. Dilution Error in Error in Factor Accuracy Precision 200 <2% <2%

Transcription:

ICP OPTICAL ATOMIC EMISSION SPECTROSCOPY Analysis of 14 Trace Elements in Stainless Steel Joël Sire, Daniel Legain Serma Technologie France Keywords: metallurgy 1 Introduction This Application Note describes a method for the routine analysis of Stainless Steel samples. Fourteen trace elements, with a wide range of concentrations, were determined using one sample preparation method. 2 Principle 2.1 Technique used The elemental analysis of these samples was undertaken by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). The sample is nebulized then transferred to an argon plasma. It is decomposed, atomized and ionized whereby the atoms and ions are excited. We measure the intensity of the light emitted when the atoms or ions return to lower levels of energy. Each element emits light at characteristic wavelengths and these lines can be used for quantitative analysis after a calibration. 2.2 Wavelength choice The choice of the wavelength in a given matrix can be made using the profile function, or by using Win-IMAGE, which is rapid semi-quantitative analysis mode using multiple wavelengths. The principle is the same in either case: record the scans of analytes at low concentration, and of the matrix. By superimposing the spectra, we see possible interferences. 3 Sample preparation 3.1 Required solutions 3.2 Calibration standards Use six 250 ml PTFE beakers. Beaker STD0: Weigh, exactly, 1250 mg of Fe. Beaker STD1: Weigh, exactly, 1244.6 mg of Fe, 1.25 mg of Cr and Ni. Beaker STD2: Weigh, exactly, 1225 mg of Fe, 5 mg of Cr and Ni. Beaker STD3: Weigh, exactly, 1167 mg of Fe, 25 mg of Cr and Ni. Beaker STD4: Weigh, exactly, 876 mg of Fe, 150 mg of Cr and Ni. Beaker STD5: Weigh exactly 636.5 mg of Fe, 250 mg of Cr and 200 mg of Ni. Beaker STD6: Weigh, exactly, 437.5 mg of Fe, 325 mg of Cr and 250 mg of Ni. In each beaker, add 6.5 ml of HF then, with care, 12.5 ml of HNO 3 and 12.5 ml of HCl. If necessary, heat on sand bath to finish the dissolution and let it cool. Transfer the solution to six 500 ml PTFE flasks and follow the instructions described below. Flask 1 (STD0): Dilute to volume with deionized water to obtain a solution of 2500 mg/l to be used as the blank sample. Flask 2 (STD1): Add 625 µl of the 1 g/l Mo, W and Mn standard Add 1.25 ml of 0.1 g/l Al, Si, Nb, Ti, V, Cu, Co standard Add 300 µl of the 0.1 g/l P standard solution. Hydrofluoric acid 40% (d = 1.13), Nitric acid 68% (d = 1.4), Hydrochloric acid 36% (1.18), Ammonium phosphate, Single element standard solutions at 1 g/l of Al, Co, Cu, Mn, Mo, Nb, P, Si, Ti, V, W, Iron powder (Johnson Matthey), Nickel and Chromium powder (Merck).

Flask 3 (STD2): Add 2.5 ml of the 1 g/l Mo, W and Mn standard Add 1 ml of 1 g/l Al, Si, Nb, Ti, V, Cu, Co standard Add 1.20 ml of the 0.1 g/l P standard solution. Flask 4 (STD3): Add 5 ml of the 1 g/l Mo, W and Mn standard Add 2.5 ml of 1 g/l Al, Si, Nb, Ti, V, Cu, Co standard Add 250 µl of the 1 g/l P standard solution. Flask 5 (STD4): Add 12.5 ml of the 1 g/l Mo, W and Mn standard Add 5 ml of 1 g/l Al, Si, Nb, Ti, V, Cu, Co standard Add 500 µl of the 1 g/l P standard solution. Flask 6 (STD5): Add 30 ml of the 1 g/l Mo, W and Mn standard Add 10 ml of 1 g/l Al, Si, Nb, Ti, V, Cu, Co standard Add 1 ml of the 1 g/l P standard solution. Flask 7 (STD6): Add 50 ml of the 1 g/l Mo, W and Mn standard Add 15 ml of 1 g/l Al, Si, Nb, Ti, V, Cu, Co standard Add 2.5 ml of the 1 g/l P standard solution. 4. Instrument specification The work was done on a JY 80 instrument and is also applicable to the JY 180 and ULTIMA 2CHR ICP spectrometers. The specifications of this instrument are listed on the following page.the specifications of this instrument are listed in Tables 1 to 3. Table 1: Specification of spectrometer: monochromator Mounting Focal length Nitrogen purge Variable resolution Grating number of grooves Czerny Turner 1m 3600 gr/mm Table 2: Specification of spectrometer: polychromator Mounting Focal length Nitrogen purge Grating number of grooves Paschen Runge 1m 3000 gr/mm Table 3: Specification of RF Generator Type of generator Observation Frequency Control of gas flowrate Control of pump flow Cooling Solid state Radial 40.68 MHz by computer by computer air 3.3 Sample preparation Weigh, exactly, 1g of sample to analyze. Add 5 ml of HF then add carefully 10 ml HNO 3 and 10 ml of HCl. Heat on a sand bath until the sample is dissolved and transfer to plastic 100 ml flask. Take care that the temperature does not exceed 55 C to avoid the loss of Si during digestion of SiF 6, which is volatile. Dilute to volume with deionized water. A 10 g/l solution is obtained. Dilute it 4 times to obtain a 2.5 g/l solution, suitable for analysis. 2

5 Operating conditions The operating conditions are listed in Table 4 below. Table 4: Operating conditions Parameter RF Generator power Plasma gas flowrate Auxiliary gas flowrate Sheath gas flowrate Nebulizer flowrate Sample uptake Type of nebulizer Type of spray chamber Argon humidifier Injector tube diameter Condition 1000 W 12 L/min 0 L/min 0.2 L/min 3.2 bars (48 psi) 1.8 ml/min Cross Flow Scott 3.0 mm 6 Wavelength selection and analytical conditions For each element, the line with the highest sensitivity was used for analysis, because there were no problems with interferences. For all the elements the conditions were the same. Table 5: Analytical conditions ** Element Slits Analysis Integration (µm) mode time (sec) All elements 40 x 20 Direct peaking 10 Table 6: Wavelengths used on the simultaneous spectrometer Element Wavelength (nm) Co 228.616 Cr 267.716 Cu 324.754 Fe 259.940 Mn 257.610 Mo 202.032 Nb 316.340 Ni 231.604 Si 251.611 Ti 337.279 V 310.230 W 207.911 Table 7: Wavelengths on the sequential spectrometer Element Wevelength (nm) Al 308.215 P 178.226 The normalization or 100% method was used. The sum of the concentrations obtained is considered to be equal to 100%. The calibration curve should be undertaken with great care. This method can be used for the analysis of all types of steel alloys. 7 Results 7.1 Calibration The standards prepared are shown in Table 8 below. 3

Table 8: Standard concentration STD0 STD1 STD2 STD3 STD4 STD5 STD6 Fe 2500 mg/l 2486.2 mg/l 2450 mg/l 2334 mg/l 1752 mg/l 1273 mg/l 875 mg/l 100 % 99.6 % 98.0 % 93.3 % 70.0 % 50.9 % 35.0 % Cr 0 2.5 mg/l 10 mg/l 50 mg/l 300 mg/l 500 mg/l 600 mg/l 0.1 % 0.4 % 2 % 12 % 20 % 24 % Ni 0 2.5 mg/l 10 mg/l 50 mg/l 300 mg/l 400 mg/l 500 mg/l 0.1 % 0.4 % 2 % 12 % 16 % 20 % Mo 0 1.25 mg/l 5 mg/l 10 mg/l 25 mg/l 60 mg/l 100 mg/l Mn 0 1.25 mg/l 5 mg/l 10 mg/l 25 mg/l 60 mg/l 100 mg/l W 0 1.25 mg/l 5 mg/l 10 mg/l 25 mg/l 60 mg/l 100 mg/l Al 0 0.25 mg/l 2 mg/l 5 mg/l 10 mg/l 20 mg/l 30 mg/l Si 0 0.25 mg/l 2 mg/l 5 mg/l 10 mg/l 20 mg/l 30 mg/l Nb 0 0.25 mg/l 2 mg/l 5 mg/l 10 mg/l 20 mg/l 30 mg/l Ti 0 0.25 mg/l 2 mg/l 5 mg/l 10 mg/l 20 mg/l 30 mg/l V 0 0.25 mg/l 2 mg/l 5 mg/l 10 mg/l 20 mg/l 30 mg/l Cu 0 0.25 mg/l 2 mg/l 5 mg/l 10 mg/l 20 mg/l 30 mg/l Co 0 0.25 mg/l 2 mg/l 5 mg/l 10 mg/l 20 mg/l 30 mg/l P 0 0.06 mg/l 0.20 mg/l 0.5 mg/l 1 mg/l 2 mg/l 5 mg/l 0.002 % 0.008 % 0.02 % 0.04 % 0.08 % 0.2 % 4

ICP OPTICAL ATOMIC EMISSION SPECTROSCOPY 7.2 Accuracy The accuracy of the method was determined by analyzing a certified reference material (CRM JK27a). Table 9: Results for accuracy Element Measured Expected concentration (%) Concentration (%) Cr 16.83 16.76 Ni 12.00 12.04 Mo 2.57 2.53 Mn 1.58 1.59 W 0.023 0.028 Si 0.40 0.41 Ti 0.0006 ND V 0.041 0.04 Cu 0.19 0.20 Co 0.095 0.09 P 0.022 0.02 7.3 Repeatability The repeatability is illustrated by three measurements of 5 seconds on a certified reference material BCS 466.1. Table 10: Results for repeatability Element Obtained RSD(%) Expected Concentration Concentration (%) (%) Al 0.044 2.9 ND Co 0.023 0.92 ND Cu 0.023 0.65 ND Mn 0.69 0.67 0.698 Mo 2.21 0.71 2.19 Nb 0.030 1.3 0.029 P 0.026 11 0.020 Si 0.355 1.4 0.50 V 0.025 0.46 ND W 0.003 12 ND 7.4 Reproducibility The reproducibility of the method was tested over 2 months. During these two months, six measurements were made (01/6, 01/9, 01/15, 02/16, 02/22) on BCS 466. Table 11 below summarizes the results. Table 11: Results for reproducibility Element Obtained RSD Expected concentration (%) conc. (%) (%) Al 0.041 13 ND Co 0.023 2.8 ND Cu 0.023 2.2 ND Mn 0.70 1.23 0.698 Mo 2.21 0.85 2.19 Nb 0.031 5.7 0.029 P 0.021 17 0.020 Si 0.35 4.3 0.50 V 0.02 3 ND W 0.003 20 ND 8 Conclusion The results presented here show that the accuracy, repeatability and reproducibility are very good for the routine analysis of stainless steel. No particular difficulties were encountered in the analysis of the samples. info-sci.fr@horiba.com www.horiba.com/scientific France: HORIBA Jobin Yvon S.A.S., 16-18 rue du Canal, 91165 Longjumeau Cedex - Tel: +33 (0)1 64 54 13 00 - Fax: +33 (0)1 69 09 07 21 - Email: info-sci.fr@horiba.com USA: HORIBA Jobin Yvon Inc., 3880 Park Avenue, Edison, NJ 08820-3012. Toll-free: +1-866-jobinyvon - Tel: +1-732-494-8660 - Fax: +1-732-549-5125 Email: info-sci.us@horiba.com Japan: HORIBA Ltd., Scientific Instruments Sales Dept., Alte-Building Higashi-Kanda, 1-7-8 Higashi-Kanda, Chiyoda-ku, 101-0031 Tokyo - Tel: +81 (0)3 3861 8231 Fax: +81 (0)3 3861 8259 - Email: info-sci.jp@horiba.com Germany: HORIBA Jobin Yvon GmbH, Hauptstrasse 1, 82008 Unterhaching - Tel: +49 (0)89 46 23 17-0 - Fax: +49 (0)89 46 23 17-99 - Email: info-sci.de@horiba.com Italy: HORIBA Jobin Yvon Srl, Via Cesare Pavese 35/AB, 20090 Opera (Milano) - Tel: +39 0 2 57 60 30 50 - Fax: +39 0 2 57 60 08 76 - Email: info-sci.it@horiba.com UK: HORIBA Jobin Yvon Ltd, 2 Dalston Gardens, Stanmore, Middlesex HA7 1BQ - Tel: +44 (0)20 8204 8142 - Fax: +44 (0)20 8204 6142 - Email: info-sci.uk@horiba.com China: HORIBA Jobin Yvon SAS, Room 1801, Capital Tower No.6, Jianguomenwai Av., Chaoyang District, Beijing 100022 - Tel: +86 (0)10 8567 9966 - Fax: +86 (0)10 8567 9066 Email: info-sci.cn@horiba.com Other Countries: Tel: +33 (0)1 64 54 13 00 - Email: info.sci@horiba.com 5