SANITARY MANHOLE S-1 ENGINEERING DEPARTMENT PLATE NUMBER NEENAH R-1733 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL.

Similar documents
TYPE "A" CATCH BASIN

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

DIVISION 3: SEWER. Improvement Design Standards City of Dundee Oregon. Division 3 : Sewer Page 1

CHAPTER 6. Sanitary Sewer

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

SECTION FACILITY SANITARY SEWERS

Facility Sanitary Sewers

SDR26 material is to be used as a minimum on all U-M projects.

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SANITARY SEWER GENERAL NOTES. Sanitary Sewer Construction Notes

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION XXXX POLYMER CONCRETE PUMP STATIONS

Drainage structure refers to manholes, catch basins, leaching basins, inlets and drop inlets. Drainage structures are designated as follows.

CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers

Appendix J: Storm Conveyance Design Parameters

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS

SECTION STORM DRAIN

GWINNETT COUNTY STORM SEWER PIPE STANDARDS

DIVISION 4 SANITARY SEWERS AND STORM DRAINS

TECHNICAL SPECIFICATIONS GRAVITY AND PRESSURE SEWER LINE AND MATERIALS

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

SANITARY GRAVITY SEWER LINES. A. Sanitary sewer lines, manholes, fittings, accessories, and bedding

DUKE UNIVERSITY CONSTRUCTION STANDARDS

San Antonio Water System Standard Specifications for Construction ITEM NO. 852 SANITARY SEWER MANHOLES

Overview. Advanced Dual Wall Profile Construction. Superior Polypropylene Material

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY PHASE II

SECTION 501 GRAVITY SEWERS. U. No pipe length used shall be less than 5 feet.

PRECAST RECTANGULAR CHAMBERS

Chapter 8 TECHNICAL SPECIFICATIONS FOR CONVEYANCE SYSTEMS

Summary of the 2011 Changes

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

A. This section includes the furnishing and installation of a sanitary sewer system.

Storm Drainage Systems

Storm Drainage

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

SECTION PIPE & PIPE FITTINGS PART 1 GENERAL

PVC Fittings & Laterals for Solid-Wall PVC Sewer Pipe

PART A : CPVC PIPES AND FITTNGS (EXTERNAL WATERSUPPLY):

SECTION STORM DRAINAGE UTILITIES. B. Section : Site Restoration and Rehabilitation

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING)

ITEM 460 REINFORCED CONCRETE PIPE Description. This Item shall govern for the furnishing of reinforced concrete pipe.

3.0 DESIGN CRITERIA FOR SANITARY SEWER FACILITIES

Current Standard Plates including Transmittal Letters are available on the web at:

HITT STREET UNIVERSITY PROJECT #: CP REFER TO CP PLANS FOR ELECTRICAL DUCTBANK IN HITT STREET INSTALL:

Section XI GRAVITY SANITARY SEWER SYSTEM CONSTRUCTION PROCEDURES

D-1 THE CITY OF HARRISBURG 1 1/2" MIN. ID-2 WEARING COARSE EXISTING STREET SURFACE AC-20 SEALER (ALL AROUND) 1 1/2" MIN. ID-2 BINDER COARSE

New Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

SECTION UTILITY MANHOLES AND STRUCTURES

A. This Section includes sanitary waste and vent piping inside the building and to locations indicated.

Water and Wastewater Engineering Department

A-2000 PVC Pipe for Sanitary Sewers

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

GENERAL CONSTRUCTION SPECIFICATIONS

Daytona Beach Pier Building Renovation Jun 2010

Request for Bids Sewer Department City of Portsmouth, New Hampshire Sewer Inventory Bid #48-15

ProSeal Flex Couplings

for plumbing regulations.

SECTION 803 SEWER MANHOLES

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS

STANDARD CONSTRUCTION SPECIFICATIONS FOR SANITARY SEWERS DIVISION 50 INDEX

2. A preconstruction meeting with the TWA s staff is required prior to initiating construction.

Construction Inspection Checklists

Pulaski County, Virginia

PUBLIC WORKS SKAGIT COUNTY SAMISH ISLAND ROAD SAMISH ISLAND ROAD SLIDE REPAIR

SECTION 1A SANITARY SEWER SYSTEM - GRAVITY

Not to scale April 2016 Standard Detail SD-001

SECTION STORM UTILITY DRAINAGE PIPING

***************************************************************************************************************

GUIDANCE MEMO NO : GUIDANCE CRITERIA FOR THE SEPARATION OF WATER MAINS AND NON-POTABLE PIPELINES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

San Antonio Water System Standard Specifications for Construction ITEM NO. 850 SANITARY SEWER STRUCTURES

SUGGESTED MANHOLE FRAME SEALING SPECIFICATION (Rehabilitation)

TABLE OF CONTENTS PART II CONSTRUCTION MATERIALS AND METHODS Section 25 SANITARY SEWER AND DRAINAGE LINES 25.1 GENERAL 25.1

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD

SECTION STORM DRAINAGE AND STORMWATER MANAGEMENT

ITEM 464 REINFORCED CONCRETE PIPE

STORM DRAINAGE CHAPTER 11

STANDARDS RESOLUTION NO ADOPTED JANUARY 17, 1995

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities

A101 S001 1 SUB-BASEMENT 3/16" = 1'-0" SHEET (906) PH (906) FX 2 S101 NEW CONCRETE WALLS TO FORM WAVE TANK 3' - 0" 5' - 5"

SANITARY SEWER REHABILITATION SPECIFICATIONS

SPECIAL SPECIFICATION 3504 Septic Tank System

VILLAGE OF LOMBARD CONTRACT DOCUMENT NUMBER SS BID PROPOSAL

Construction Specifications

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

CONCRETE PIPE USE MANUAL

II: APPROVED MATERIALS FOR WATER AND WASTEWATER

SECTION TRENCHLESS INSTALLATION

SECTION FOUNDATION DRAINAGE

TITLE: SLAUGHTER HOUSE SEPTIC TANK. ITEM No. D E S C R I P T I O N UNIT QTY

SECTION SANITARY SEWERAGE UTILITIES

UNIFORM STANDARD DRAWINGS CLARK COUNTY AREA, NEVADA YEAR 2015 REVISIONS

SPECIFICATIONS FOR STREET CONSTRUCTION WITHIN THE TOWN OF PLAINVILLE

Transcription:

"INFI-SHIELD" SEAL OR EQUAL. NEENAH R-1733 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL. 27" HDPE ADJUSTING RINGS (2 MIN., 1' MAX. OF RINGS). ECCENTRIC CONE 4.0' HIGH 48" 5" P2 PROFILE GASKET PER ASTM C443 AND/OR JOINT SEAL ROPE MANHOLE STEPS, 16" O.C. (SEE NOTE 3) NET MH. BARREL HEIGHT VARIABLE HEIGHT BOTTOM MONOLITHIC SECTIONS 1.8' TO 4.0' TALL WITH POURED INVERTS AND 7.5' WITHOUT INVERTS, IN 0.1' INCREMENTS. FLOW LINE ELEVATION 6" MONOLITHIC SLAB AS REQUIRED PSX BOOT NOTES: 1. NO WOOD SHALL BE USED FOR ADJUSTING CASTING. 2. CAST IRON FRAME AND COVER AS PER SPECIFICATIONS. 3. MANHOLE STEPS SHALL BE ALUMINUM, OR STEEL REINFORCED PLASTIC PER ASTM C478. 4. PRECAST REINFORCED CONCRETE MANHOLE SECTIONS PER ASTM C478 FURNISHED WITH O-RING GASKETS AND LUBRICANT EXCEPT AS OTHERWISE SPECIFIED. LIFT HOLES NOT PERMITTED IN MANHOLE SECTIONS. 5. PIPE CONNECTIONS TO MANHOLE SHALL BE MADE WATER TIGHT BY CAST IN PLACE RUBBER BOOT AND CEMENT MORTAR. INSIDE SURFACE SHALL BE FINISHED SMOOTH. REVISIONS SANITARY MANHOLE S-1 SANITARY MANHOLE.dwg

"INFA-SHIELD" SEAL OR EQUAL. RINGS (2 MIN., 1.0' MAX. OF RINGS & MORTAR) 1/2" MORTAR ON OUTSIDE, BETWEEN RINGS, CASTING & MANHOLE. FINISH SMOOTH ON THE INSIDE. 2 STRIPS BITUMASTIC SEAL AT SLAB JOINTS. 27" 48" TYPE 2 COVER SLAB 8" 48 " VARIABLE SLOPE BENCHES 1/2" PER FOOT 2 STRIPS BITUMASTIC SEAL AT SLAB JOINTS. 16" O.C. 16" MIN. 4.5' MIN. 10' MIN. CEMENT MORTAR VARIES PRECAST BASE MH DIA. 48" 54"-102" 108" 120" SLAB THICKNESS 6" 8" 10" 12" VARIES NOTES: NO WOOD SHALL BE USED FOR ADJUSTING CASTING, CEMENT MORTAR ONLY. CAST IRON MANHOLE FRAME & COVER AS PER SPECIFICATIONS. MANHOLE STEPS SHALL BE CAST IRON, ALUMINUM OR STEEL REINFORCED PLASTIC PER ASTM C478. STEP LOCATION SHALL BE AS NOTED IN THE SPECIFICATIONS. PRECAST REINFORCED CONCRETE MANHOLE SECTIONS PER ASTM C478, FURNISHED WITH O-RING GASKETS AND LUBRICANT EXCEPT AS OTHERWISE SPECIFIED. INSTALL 12" OR 16" BARREL SECTION UNDER THE CONE WHENEVER POSSIBLE. PIPE CONNECTIONS TO MANHOLE SHALL BE MADE WATER TIGHT BY CAST INPLACE. REVISIONS SANITARY SEWER MANHOLE (27" OR MORE) S-2 SANITARY SEWER MANHOLE (27 INCH).dwg

LC STREET 4" PVC CLEANOUT PROPERTY LINE INSTALL 6' METAL FENCE POST 1/8 BEND MINIMUM PIPE SLOPE 1/4" PER FOOT 4" PVC PIPE VARIABLE 4" x 4" WYE 4" PVC CAP 10' MINIMUM DEPTH DETERMINED IN FIELD SERVICE WYE GRAVITY MAIN 1/2 PIPE DIAMETER MINIMUM NOTE: MATERIAL SERVICE CONNECTIONS SHALL BE 4" PVC SDR 26 OR SCHEDULE 40. 10/15 SANITARY SEWER SERVICE S-3 SANITARY SEWER SERVICE.dwg

NOTE: DIMENSION "A" IN CHART IS BASED ON A 27" DIAMETER OPENING. INCREASE "A" BY 1.5" FOR 24" OPENING. DIMENSIONS IN INCHES P K T W A B 48" 6" DIMENSION CHART MANHOLE TYPE C 60" 7" D 72" 8" E 84" 9" F 96" STEPS MANHOLE G 102" 9" 9" 6" 8" 8" 8" 8" 8" 58" 72" 86" 100" 113" 119" 9.5" 15.5" 21.5" 27.5" 34.5" 38" C L LC A K COVER SLAB W = SLAB DIA. 27" DIAMETER OPENING PIPE CL REINFORCE SLAB FOR STREET LOADING R-1733 OR R-1733-1 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL. "INFA-SHIELD" SEAL OR EQUAL. 16" T 27" RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR). PLASTER OUTSIDE, STRIKE INSIDE CLEAN. P RUBBER GASKET TYPICAL ALL JOINTS. 16" R.C.P. BARREL SECTION DEPTH VARIES PRECAST SECTION STEP-SEE SPECS. CONC. BLOCK MASONRY TO BE USED ONLY WHERE NECESSARY. PLASTER OUTSIDE, STRIKE INSIDE CLEAN. 3' 8" POURED 6" PRECAST REVISIONS MANHOLE TYPE B THRU G SUMP.dwg MANHOLE: TYPE B THRU G WITH SUMP S-4

LC STREET 4" PVC CLEANOUT PROPERTY LINE INSTALL 6' METAL FENCE POST 45 BEND VARIABLE 10' MINIMUM DEPTH DETERMINED IN FIELD SERVICE WYE MINIMUM PIPE SLOPE 1/4" PER FOOT 4" PVC, SDR 26 4" x 4" WYE 4" PVC CAP 45 BEND RISER LENGTH VARIABLE 2' MIN. LENGTH REQUIRED GRAVITY MAIN 1/2 PIPE DIAMETER MINIMUM TYPE "A" SERVICES TO BE USED IN CONJUNCTION WITH PLASTIC PIPE SEWER MAIN FOR ALL DEPTHS OF COVER, AND CLAY SEWER MAINS WITH LESS THAN 12 FEET OF COVER. ALL SERVICE PIPE TO BE INSTALLED AND BEDDED IN ACCORDANCE WITH THE APPROPRIATE PIPE BEDDING DETAIL AS INDICATED ON THE PLANS/SPECIFICATIONS. 10/15 SANITARY SEWER SERVICE WITH RISER.dwg SANITARY SEWER SERVICE WITH RISER S-5

EXISTING SANITARY SEWER WYE (WYE IS DAMAGED OR BROKEN) EXISTING VCP SANITARY SEWER PIPE EXISTING CONDITION OPTION A EXISTING VCP SANITARY SEWER PIPE SPOT LINE EXISTING SANITARY SEWER MAIN THROUGH WYE PROPOSED CONDITION EXISTING SANITARY SEWER WYE (WYE IS IN GOOD CONDITION) EXISTING VCP SANITARY SEWER PIPE EXISTING CONDITION OPTION B INSTALL MECHANICAL CAP ON EXISTING WYE EXISTING SANITARY SEWER PIPE PROPOSED CONDITION 03/18 SANITARY SEWER WYE REPLACEMENT S-6 SANITARY SEWER WYE REPLACEMENT.dwg

EXISTING SANITARY SEWER WYE EXISTING VCP SANITARY SEWER PIPE EXISTING SANITARY SEWER WYE EXISTING CONDITION EXISTING VCP SANITARY SEWER PIPE 45 BEND PVC, SDR 26 SANITARY SEWER SERVICE PIPE PROPOSED CONDITION NOTE: ALL PVC PIPE TO BE INSTALLED AND BEDDED IN ACCORDANCE WITH THE APPROPRIATE PIPE BEDDING DETAIL AS INDICATED ON THE PLANS/SPECIFICATIONS. 10/15 SANITARY SEWER SERVICE REPLACEMENT S-7 SANITARY SEWER SERVICEV REPLACEMENT.dwg

C STREET PROPERTY LINE SERVICE WYE LESS THAN 12' FOR CLAY PIPE BEND 4" PVC PIPE VARIABLE MATCH EXISTING SLOPE EXISTING SEWER SERVICE GRAVITY MAIN 1/2 PIPE DIA. MINIMUM FERNCO CONNECTION WITH CONCRETE COLLAR NOTE: MATERIAL SERVICE CONNECTIONS SHALL BE 4" PVC SDR 26 OR SCHEDULE 40. 10/15 SANITARY SEWER SERVICE PIPE REPLACEMENT S-8 SANITARY SEWER SERVICE PIPE REPLACEMENT.dwg

EXISTING CIPP LINER EXISTING SANITARY SEWER PIPE EXISTING CONDITION SANITARY SEWER SERVICE WYE BRANCH EXISTING SANITARY SEWER PIPE SANITARY SEWER SERVICE PIPE STAINLESS STEEL CLAMPS PVC SADDLE SHIELD UNIVERSAL PVC SADDLE "T" EXISTING CIPP SANITARY SEWER CORE DRILL EXISTING PIPE PROPOSED CONDITION NOTE: 1. FOR 4" OR 6" SERVICES, INSTALL PIPECONX SADDLE TEE OR APPROVED EQUAL. 2. FLEXIBLE SADDLE MUST BE INSTALLED IN COMBINATION WITH SADDLE SHIELD. 10/15 SANITARY SEWER SERVICE INSTALLATION FOR CIPP S-9 SANITARY SEWER SERVICE INSTALLATION FOR CIPP.dwg

7.5" R 15" 3" 3" 18" 6" 7.5" 3" SECTION PLAN HORSESHOE DETAILS "INFI-SHIELD" SEAL OR EQUAL. NEENAH R-1733 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL. 27" HDPE ADJUSTING RINGS (2 MIN., 1' MAX. OF RINGS). ECCENTRIC CONE 4.0' HIGH P2 PROFILE GASKET PER ASTM C443 AND/OR JOINT SEAL ROPE CUT BELL FROM DIP AND JOIN WITH FERNCO TYPE COUPLER OR EQUAL. MANHOLE STEPS, 16" O.C. (SEE NOTE 3) NET MH. BARREL HEIGHT 48" 5" 8" DIP TEE SECTION VARIES 12" - 16" 20' DIP VARIABLE HEIGHT BOTTOM MONOLITHIC SECTIONS 1.8' TO 4.0' TALL WITH POURED INVERTS AND 7.5' WITHOUT INVERTS, IN 0.1' INCREMENTS. VARIABLE DROP SIZE 6" MONOLITHIC SLAB PSX BOOT (TYP) AS REQUIRED HORSEHOES FILLED WITH CONCRETE MORTAR ON ALL SIDES (SEE DETAIL) NOTES: 1. NO WOOD SHALL BE USED FOR ADJUSTING CASTING. 2. CAST IRON FRAME AND COVER AS PER SPECIFICATIONS. 3. MANHOLE STEPS SHALL BE ALUMINUM, OR STEEL REINFORCED PLASTIC PER ASTM C478. 4. PRECAST REINFORCED CONCRETE MANHOLE SECTIONS PER ASTM C478 FURNISHED WITH O-RING GASKETS AND LUBRICANT EXCEPT AS OTHERWISE SPECIFIED. LIFT HOLES NOT PERMITTED IN MANHOLE SECTIONS. 5. PIPE CONNECTIONS TO MANHOLE SHALL BE MADE WATER TIGHT BY CAST IN PLACE RUBBER BOOT AND CEMENT MORTAR. INSIDE SURFACE SHALL BE FINISHED SMOOTH. REVISIONS SANITARY DROP INLET MANHOLE.dwg SANITARY DROP INLET MANHOLE S-10

CORE DRILL AND SEAL WITH MORTAR DIP PIPE CONCRETE SUPPORT 27" SECTION A -A 48" 5" ACCESS OPENING A "INTRA FLOW" OR APPROVED EQUAL WITH RAIL SYSTEMS A FLOW CONSTRUCT CHANNEL REVISIONS 2-22-17 INSIDE DROP MANHOLE ADDITION S-11 INSIDE DROP MANHOLE ADDITION.dwg