GROUND CONTROL THAT WORKS

Similar documents
Greenleaf Urban tree and landscape products. Turf reinforcement module for porous vehicular surfaces

Gravel Stabilisation

GROUNDtrax GROUNDGRIDZ

Applications. 5 reasons why you should choose Hebden X Grid cellular paving

Plastic Permeable Paving

Hebden 402 Permeable Ecopaving Information Sheet

Sudspave. Cellular porous paving system

GRASS, GROUND & GRAVEL REINFORCEMENT

TURF CELL Porous Paving System

For Grassed Surfaces Typical Construction Profile

SECTION POROUS PAVEMENT SYSTEM

LAYING IBSTOCK CLAY PAVERS FOR PERMEABLE PAVEMENTS

TRUEGRID PRO PLUS Permeable Paver Technical Specifications

Resin Bound and Bonded Surfacing. RonaDeck UV Rubber Granule Tree Pit Base. Resin bound rubber granule porous tree pit system.

PART 1 - GENERAL 1.01 General Provisions A. The Conditions of the Contract and all Sections of Division 1 are hereby made a part of this Section.

NOVEMBER 2016 GRANDWALL. retaining walls installation guide

EcoGran UV Resin Bound Surfacing System

CITY OF LETHBRIDGE SECTION Construction Specifications SIDEWALK CONSTRUCTION PAGE 1 of 5

HOW TO INSTALL PATIOS AND WALKWAYS STEP 2 STEP 1. For all Patios and Walkways. The base is the most important step in your patio and walkway projects.

INNOVATIVE OUTDOOR SOLUTIONS

SECTION 1 STALOK FIBER FOR TURF PARKING / EVENT STAGING AND FIRE LANES

PROJECT AT THE DENVER

GREEN LANDSCAPING ALTERNATIVES FOR A SUSTAINABLE FUTURE GRAVEL

REPORT STATUS: DATE: Report n :

Reinforced concrete slot channel

Best Practices for Building High-Performance Resource Roads. Road Drainage. Developed by: The Roads and Infrastructure Group

Anchorplex retaining wall construction guide. Building. Anchorplex. Retaining Wall Systems

Tasman Retaining Wall System

Construction Specification for Concrete Unit Pavers

INTERLOCK BETWEEN PARTICLES AT EACH PERFORATION

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

Silva Cell. Silva Cell Two-Deep Installation Instructions. Helping Trees Live in the Urban Environment

PERMEABLE PAVERS PHYSICAL AND GEOMETRICAL CHARACTERISTICS - PAVERS DRIVEWAYS, PERMEABLE DRIVEWAYS & PATIOS CHARACTERISTICS CSA A231.

AUGUST 2017 HASTINGS. retaining walls installation guide

SECTION Stabilizer Apache Warning Track Mix for baseball or softball field surfacing

Section Soil Erosion Protection Tender No. [ ] Page 1

HOW TO INSTALL PATIOS AND WALKWAYS STEP 2 STEP 1. For all Patios and Walkways. The base is the most important step in your patio and walkway projects.

CRUSHED AGGREGATE BLENDED WITH GRANITECRETE ADMIXTURE SURFACING

ECO OUTDOOR INSTALLATION TIPS FLOORING TORINO MELBOURNE SYDNEY BRISBANE ADELAIDE PERTH T ECOOUTDOOR.COM.AU

FINAL REPORT: Laboratory evaluation of SupraSorb rootzone amendment material for sports turf rootzone mixes

Complete Modern Drainage System

Procedure and Specification for the Construction of Vehicle Access Crossings over Footways and Verges April 2016

SECTION 14 - RESTORATION OF SURFACES TABLE OF CONTENTS

NORTHERN QLD LANDSCAPING COLLECTION RETAINING WALLS. style and function

THE STRONG GRAVEL STABILISATION SYSTEM

CETCO-VOLCLAY CG-50 SPECIFICATION GUIDELINES MIX IN PLACE

SYNTHETIC GRASS INSTALLATION GUIDE SOFT AND HARD SURFACE

NOVEMBER 2016 MAGNUMSTONE. retaining walls installation manual

Section 1I-3 - Bioswales

G R A V I T Y / G E O G R I D

asphalt applications Asphalt surfacings for high stress areas mpa asphalt Asphalt Information Service Mineral Products Association

BMP 6.4.4: Infiltration Trench

GEOPAVE POROUS PAVEMENT SYSTEM

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM

BENTOMAT CL GEOSYNTHETIC CLAY LINER SPECIFICATION GUIDELINES

CHAPTER 3 CONSTRUCTION AND TESTING OF SUBGRADE

Grasscrete. the environmental paving solution

Modular Sediment Barriers (Instream)

Resin Bound Installation Guide

CHARACTERISTICS CSA A TECHO-BLOC Compressive strength psi [45 MPa] min.

Tasman and Norfolk Retaining Wall

MACHINE-LAY Installation Manual

DESIGN STANDARDS. Division 02 Existing Conditions- Site Work. General

How To Install Your Cambridge Pavingstones System How To Install Your Cambridge Segmental Retaining Wall System

NOTES ON CORRUGATED PLASTIC PIPE SUBSOIL DRAIN CONSTRUCTION SPECIFICATION

ITEM 6 CONCRETE CURBS, GUTTERS, AND SIDEWALKS

Landscaping and Fencing

PERMEABLE INTERLOCKING PAVERS

GRANDE WALL large CONCRETE BLOCKS FOR THE CONSTRUCTION OF RETAINING WALLS. 1339_Feuillet_Permacon_Grande_ang.indd 1

Glass Reinforced Concrete DRAINAGE CHANNELS

R-TANK SPECIFICATIONS

CITY OF FARGO SPECIFICATIONS AGGREGATE BASES

ACO Construction & Building Products

StormTech Construction Guide

Polymeric Sand. Guide. for Pavement Joints. Installation. Easy to use Stays within joints HP POLYMERIC SAND RG+ POLYMERIC SAND. techniseal.

SECTION TRENCHING & BACKFILLING

4.8. Subsurface Infiltration

Eco Resin Bound UV Surfacing System

INDEX FOR SPECIFICATIONS FOR REMOVING CULVERTS AND PLACING CULVERTS SCOPE... 1

HYDROGRID SUBSURFACE IRRIGATED HARTRU TENNIS COURTS

SECTION 14 - RESTORATION OF SURFACES TABLE OF CONTENTS

4 EXTREME FOUNDATION PANELS

4.8. Subsurface Infiltration

Installation Information 2016

Construction Best Management Practices Handbook BEST MANAGEMENT PRACTICES

Instructions for installation the GRAF EcoBloc Inspect flex

Asphalt Maintenance PRODUCTS INFORMATION AND INSTALLATION GUIDE

Storm Drain Inlet Protection

Rainwater Harvesting Tank

Nursery and Landscape Skill Events

CHARACTERISTICS CSA A TECHO-BLOC Compressive strength 50 MPa [7200 psi] min. 50 MPa [7200 psi] min.

Box Culverts. Easy to install, suitable for very shallow or deep fill, ideal for use in a wide variety of civil engineering applications.

EXCAVATION & BACKFILLING GUELPH TRANSIT OPERATIONS & MAINTENANCE SECTION WATSON ROAD FACILITY PAGE 1 OF 6 WATER RECLAMATION PROJECT JUNE 2013

Presentation to the 60 th Annual NJ Asphalt Paving Conference March 14, 2017 Ewing, NJ

Instructions for 12 IGT system

GreenScape Ltd. EcoPave Grids

Memorandum. FOUNDATION ENGINEERING, INC. Professional Geotechnical Services. Date: August 13, 2012 To:

A.2.a Random Riprap... Table

HP and RG POLYMERIC SANDS for PAVEMENT JOINTS

SPECIFICATIONS FOR RUBAROC SAFETYDECK (FOR PLAYGROUND SURFACES)

Transcription:

GROUND CONTROL YOUR ESSENTIAL GUIDE TO GRASS AND GRAVEL STABILISATION GRASS AND GRAVEL GRID SYSTEMS GROUNDRINGS GROUND CONTROL

GROUND CONTROL EARTHWORX Groundrings is a plastic modular grid system with different panels for reinforcement and stabilisation of grass and gravel surfaces. All Groundrings products are manufactured using 100% recycled and recyclable, UV stabilised plastic. * The unique ring design has been selected for its optimum strength when used in grass or gravel paving as it has no weak corners and is suitable for pedestrian and vehicular traffic. Groundrings panels, once installed create a fully permeable layer offering a natural alternative to hard landscaped surfaces. This porous and free-draining design eliminates water run-off thus reducing demand on surface water drainage systems and making it suitable for use in SuDS (sustainable urban drainage systems) compliant schemes. Whether installing a Grass or Gravel module, Groundrings panels are very quick to lay, providing a cost effective solution when compared to other porous hard landscape surfaces. The unique but simple clip mechanism makes the panels very easy to join together. Grass and Gravel panels are compatible meaning they can be used together on mixed schemes. Joints can be staggered and panels easily cut to follow borders and edgings to minimize wastage. GROUNDRINGS * White panels are made from part recycled material GROUND CONTROL IDEAL FOR CARAVAN PARKS GOLF COURSES DRIVEWAYS USE EARTHWORX GROUNDRINGS IN CONJUNCTION WITH... GEOTEXTILE FABRIC GEOTEXTILE FABRIC 2 FIND OUT MORE: 3

circles, cross-overs and any areas more exposed to regular traffic. The number of pins required will depend on the application and site conditions but as a guide allow 1 pin per panel (4 per m²). 1. Excavate soil (sub-grade) to the required depth (allowing for sufficient depth of sub-base material and the panels / surface finish). GROUND CONTROL 2. Lay DRAINTEX or DRIVETEX geotextile fabric as per instructions for relevant product. 3. Secure using EXTRAFIX fixing pegs. 4. Lay stone sub-base layer (e.g. MOT Type 1 or 3 - Type 3 must be used for porous installations) to the required depth, compact and level to engineer s specification. 5. Blind the surface with a layer of sharp sand or granite fines to level out any undulations in the sub-base before laying the panels. 6. Lay the Groundrings Gravel panels over the base with the mesh side down and clip together. Fix down using Groundrings Fixing Pins (if required). It is recommended that fixing pins are used on slopes, edges, turning 7. Leave a gap (min 50mm) when adjoining a kerb or any other type of fixed edging, obstruction or structure, to allow for expansion of the panels. 8. Spread the final gravel surface over the panels to a depth of approx 10-15mm higher than the top edge of the rings, so that they are concealed. 9. Rinse the gravel with water (if required) and lightly compact the gravel to aid settlement and consolidation. NOTES: These instructions are provided as a guide only and do not offer any warranty (express or implied) since the site conditions and requirements can vary. G R O U N D R I N G S G R AV E L INSTALLATION GUIDELINES EARTHWORX Groundrings Gravel panels are an effective method of containing and stabilising loose aggregate surfacing. This helps to prevent gravel migration, sinking and rutting and makes it possible to walk, cycle and push wheeled vehicles (e.g. wheelchairs and pushchairs) over the surface. The unique design of the grid includes an open mesh base which allows water to pass through whilst preventing the build-up of silt and fine debris within the cell. This prevents the aggregate working its way underneath the grid, causing it to lift and making it very difficult to rectify. Unique ring design = optimum strength Excellent load bearing capacity Suitable for pedestrians and vehicles Open mesh base = no silt build up Fully permeable gravel surface Prevents gravel migration, sinking and rutting Quick and easy to install 25mm deep = uses less gravel Fully compatible with Grass panels 4 TECHNICAL DATA Panel Size 500mm x 500mm Panel Depth 25mm (+ mesh base = 28mm overall) Cell Diameter 50mm Gravel Size (recommended) 6mm 20mm (angular only) Gravel Demand 45 50kg per m2 Material 100% recycled*, UV stabilised HDPE Resistance Chemical resistant Colour Black (white available to order) Load Bearing Capacity 350 tonnes per m2 * White panels are made from part recycled material 5

GROUND CONTROL INSTALLATION GUIDELINES 1. Excavate soil (sub-grade) to the required depth (allowing for sufficient depth of sub-base material plus 50mm). The depth of the sub-base will vary depending on the intended use and engineer s specification. As a guide it should be a minimum of 75-100mm for pedestrians, 100-150mm for light vehicles and 200-300mm for trucks. 2. Lay DRAINTEX or DRIVETEX geotextile fabric as per instructions for relevant product. 3. Secure using EXTRAFIX fixing pegs. 4. Lay stone sub-base layer (clean angular load bearing stone without clay fines) to the required depth, compact and level to engineer s specification, 40-50mm below the final finish level. 5. Add and spread evenly a thin layer (20-30mm) of sand (rounded root zone sand with an even sized particle distribution) and wash or roll into the sub-base until the stone is almost visible. 6. Evenly spread a layer of water storing polymer at a rate of 4kg per 100m² (using a mechanical rotary spreader). 7. Lay the Groundrings Grass panels over the base and clip together. Cut around obstructions, trees, kerbs etc leaving a gap (min 50mm) to allow for expansion. 8. Evenly spread a grass starting fertiliser (see tech data) at a rate of 7kg per 100m² (using a mechanical rotary spreader). 9. Half fill (approx 15mm) the rings with a suitable root zone mix (see tech data). 10. Spread grass seed (see tech data) at a rate of 5kg per 100m² (using a mechanical rotary spreader). 11. Finish filling the rings with the root zone material using a large broom to ensure the top edge of the rings remains exposed. 12. Fertilise the seeded area again (see tech data) at a rate of 7kg per 100m² (using a mechanical rotary spreader). 13. After installation the area must be kept moist. Consideration should be given to additional watering during extended periods of dry weather. The area must be protected from traffic for a minimum of 8 weeks or two cuts until the grass has fully established. Regular maintenance will be required including watering and fertilising in the spring/summer. The grass should be cut at approx 50mm and certainly no less than 30mm. NOTES: These instructions are provided as a guide only and do not offer any warranty (express or implied) since the site conditions and requirements can vary. GROUNDRINGS GRASS EARTHWORX Groundrings Grass panels are an effective method of stabilising and reinforcing grass surfaces. This helps to prevent compaction of the root zone layer, enabling the grass roots to obtain the necessary oxygen, moisture and nutrients they need from the soil to survive. The unique open grid structure of the panel provides over 90% root development area, meaning the roots can grow laterally without hindrance, resulting in 100% grass cover. This modular system is suitable for grass parking areas that are subject to infrequent use only, such as overflow car parks, access roads etc. It is not recommended for parking areas with permanent or regular use. Unique ring design = optimum strength Excellent load bearing capacity Suitable for pedestrians and vehicles Open grid structure = lateral root growth Fully permeable grass surface Prevents compaction of root zone Quick and easy to install Flexible = can follow undulations Fully compatible with Gravel panels TECHNICAL DATA Panel Size Panel Depth 500mm x 500mm 30mm Cell Diameter 50mm Pre-Seed Fertiliser (recommended) 10% nitrogen, 15% phosphate and 10% potassium Root Zone (recommended) 70% sand & 30% recycled compost mix ph 6.5 7.2 Grass Seed (recommended) Greenvelvet Watersaver by Barenbrug Material 100% recycled, UV stabilised HDPE Resistance Chemical resistant Colour Black Load Bearing Capacity 350 tonnes per m 2 6 7

AVAILABLE FROM: FIND OUT MORE: GROUND CONTROL The information in this brochure is given in good faith and does not offer any warranty (express or implied) regarding the suitability of any product for your use as site conditions and requirements can vary. The user must ensure that the product is suitable for the specific application, as these products will not compensate for poor workmanship or exceptional ground conditions. Growtivation reserves the right to alter product specifications and information without prior notice. E&OE. Growtivation 2015