Hilti HIT-HY150 Injection Adhesive with HAS-E/ER/EF/HCR and HIS-N/RN

Similar documents
Anchor Fastening Technology Manual. HIT-HY 170 mortar with rebar (as anchor) Hilti HIT-HY 170 mortar with rebar (as anchor) Version

Hilti HIT-RE 500 V3 mortar with HIT-V rod

HVU with HAS/HAS-E rod adhesive anchor system

Hilti HIT-HY 200 A (R) mortar with HIT-V rods

Hilti-HY 110 available in 330ml and 500ml foil packs. Static mixer HIT M1. Rebar BSt 500 S

Hilti HST3 Metal Expansion Anchor

Hilti HVU-TZ foil capsule. HAS-TZ HAS-R-TZ HAS-HCR-TZ rod. Shock

Anchor HSA Fastening. Technology Manual HSA. Stud anchor. Version /

HST Carbon steel. HST-R Stainless steel HST-HCR High corrosion resistance steel. Fire resistance

HKD Push-in anchor, Single anchor application

HKD Push-in anchor, Single anchor application

HST2 Expansion anchor Everyday standard expansion anchor for cracked concrete

HUS-HR / HUS-CR Screw anchor

AC100-PRO. AC100-PRO Vinylester 160ML AC100-PRO Vinylester 300ML AC100-PRO Vinylester 360ML AC100-PRO Vinylester 410ML AC100-PRO 160ML AC100-PRO 300ML

Trutek TCM380 PRO. Trutek Fasteners Polska Al. Krakowska 55 Sekocin nowy Rasxyn Poland T:

Anchor Fastening Technology Manual. HIT-HY 170 mortar with rebar. Hilti HIT-HY 170 mortar with rebar (as post-installed conn.


European Technical Assessment ETA-15/0288 of 17/06/2015

English translation prepared by CSTB - Original version in French language

Injection Adhesive VM-PY

High-performance anchoring adhesive. n Styrene-free n Low odour n Low wastage n No transportation restrictions

HUS3-H 8 / 10 / 14 Carbon steel concrete screw with hexagonal head. HUS3-C 8 / 10 Carbon steel concrete screw with countersunk head

MKT Fixing. JAM The Professional Standard. Quality Management. Environmental Management. Energy Management

Hilti HDA Submission Folder

SVM-PSC Polyester resin for use in concrete

English translation prepared by CSTB - Original version in French language. Injection system Hilti HIT-RE 500 V3

Anchor Fastening. Technology Manual HUS3. Screw Anchor HUS3-H 6/8/10/14 HUS3-C 6/8/10 HUS3-HF 8/10/14 HUS3-A 6 HUS3-I 6 HUS3-P 6 HUS3-PS 6 HUS3

AC50 Silver Adhesive Anchoring System

Sormat ITH-Pe PRODUCT DATA SHEET. ITH-Pe - POLYESTER BASED RESIN STYRENE FREE. Polyester based injection resin, styrene free. ITH 165 Pe art.

European Technical Assessment ETA-14/0454 of 11/12/2014

VF22PRO Chemical Injection System STYRENE-FREE INJECTION SYSTEM - VINYLESTER

This Technical Assessment meets the testing requirements stipulated in Standards Australia Technical Specification: SA TS101:2015

System Components. Grades. General Information Installation Information

HRD PLASTIC ANCHOR. Technical Datasheet Update: Dec-17

HRD-U 10 / - S 10 / -U 14 Frame anchor

HSV Carbon steel with DIN 125 washer. HSV-BW Carbon steel with DIN 9021 washer and DIN 127b spring washer

HRD Frame anchor, Redundant fastening

HSV. with DIN 125 washer HSV-BW. Carbon steel. with DIN 9021 washer and DIN 127b spring washer


English translation prepared by CSTB - Original version in French language

EPCON C8. Cracked Concrete - Anchor Studs 43.1 CRACKED CONCRETE - CHEMICAL INJECTION 43.1 GENERAL INFORMATION

SOUDAFIX VE400-SF. Temperature -10 C (1) -5 C 0 C 5 C 10 C 20 C 30 C 35 C 40 C

weber.anc 405 BFX formerly Conrep.405 BFX

European Technical Approval ETA-11/0344

AC200+ Acrylic Injection Adhesive Anchoring System

General Information. Installation Information Design Information Material Information Ordering Information

Construction. Universal anchoring adhesive. Product Description. Tests. Product Data Sheet Edition _1. 1 Sika AnchorFix S 1/6

English translation prepared by CSTB - Original version in French language

European Technical Approval ETA-08/0058

English translation prepared by CSTB - Original version in French language

European Technical Approval ETA-04/0027

ESR ICC Evaluation Service, Inc. Reissued January 1, 2008 This report is subject to re-examination in one year.

High Strength Epoxy tested in accordance to ICC-ES AC308

English translation prepared by CSTB - Original version in French language. Injection system DeWalt PURE110-PRO

C6+ High Strength Epoxy for All. conditions. One product for most environmental conditions and weather conditions. Curing Times

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 17.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

High Strength Epoxy tested in accordance to ICC-ES AC308

High-performance Anchoring Adhesive

AC100+ GOLD Vinylester Injection Adhesive Anchoring System

Styrene free Urethane hybrid adhesive

APPENDIX A: Strength Design Performance Values

Easy to Use A7 Saves You Time and Money

Hilti HIT-RE 500 post-installed rebars

Chemical Anchoring Reinforcing Bar Anchorage

Adhesive Anchoring Selection Guide Solid Concrete Applications

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS

R-RBP Rawlbolt - Bolt Projecting for use in cracked and non-cracked concrete.

High Strength Epoxy Tested in Accordance with ICC-ES AC308

High Strength Epoxy Tested in Accordance with ICC-ES AC308

AC100+Gold. Vinylester Injection Adhesive Anchoring System PRODUCT DESCRIPTION FEATURES AND BENEFITS

ChemSet 101 PLUS. Chemical Anchoring - Anchor Studs 12.1 CHEMICAL INJECTION ANCHORING 12.1 GENERAL INFORMATION. Product

European Technical Assessment. ETA 15/0226 of General Part TCM400PE, TCM600PE. Trade name of the construction product

Adhesive Anchors SECTION CONTENTS. General Information. Installation Information Design Information Material Information Ordering Information

EPCON C8. Chemical Anchoring - Reinforcing Bar Anchorage 16.1 CHEMICAL INJECTION ANCHORING

Trusted ICC ES HILTI, INC. SYSTEM E ANCHOR. Conformity! Look. Evaluation. ICC-ES Evaluation

Racking Solutions for Timber Framed Buildings T-RS-UK Edition. +44 (0)

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Concrete screw BSZ Steel/steel zinc flake coated

English translation prepared by CSTB - Original version in French language. Throughbolt PTB-ETA7-PRO

HRD-U 10 / - S 10 / -U 14 Frame anchor

European Technical Assessment ETA-16/0865 of 08/11/2016

Hilti X-EGN Nails. Submission Folder

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.1.

European Technical Approval

European Technical Assessment. ETA-17/0237 of 15/05/2017. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

CHEMICAL ANCHORING. Specifi ers Anchoring Resource Book Book 3.3 of 3 CHEMICAL ANCHORING

ICC-ES Evaluation Report. ESR-3342 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

(English language translation, the original version is in Czech language) MA Green Plus

Submittal Information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS

Mapefix PE Wall. Chemical anchor for masonry and light loads

(English language translation, the original version is in French language) DeWalt PB-SS-PRO 01/02/ /06/2017. Plant 1 & 2

MULTI-MONTI Technical Manual

PACTORep Fixer EASF AVAILABILITY. Working Hardening 3h 2h 1h30 1h Anchor Installation Resistance Admissible loads

EPCON C6. Chemical Anchoring - Anchor Studs 9.1. Principal Applications CHEMICAL INJECTION ANCHORING 9.1 GENERAL INFORMATION

(English language translation, the original version is in French language) Société SPIT Route de Lyon - B.P BOURG-LES-VALENCE FRANCE

CONCRETE ANCHORING SYSTEMS

Sormat ITH-Ve PRODUCT DATA SHEET. ITH-Ve - VINYLESTER BASED RESIN STYRENE FREE. Vinylester based injection resin, styrene free

General Construction Supervisory Authority Approval

Transcription:

Submission folder Hilti HIT-HY150 Injection Adhesive with HAS-E/ER/EF/HCR and HIS-N/RN Sample Submission and 2-9 Approval Form Product Information 10-17 Technical Information - HY150 + HAS/E/ER/EF/HCR 18-23 - HY150 + HIS-N/RN 24-28 Method Statement - HY150 + HAS/E/ER/EF/HCR 29-30 - HY150 + HIS-N/RN 31-32 Test Reports according to BS5080 - HY150 + HAS Anchor Rod 33-44 Government Letter 45-46 Country of Origin 47-49 Material Safety Data Sheet 50-55 Job Reference 56-65 Customer Hotline Hong Kong 8228 8118 Macau (Toll free) 00800-8228 8118 Page 1 Fen 2012

SAMPLE SUBMISSION AND APPROVAL FORM Contract Title: Ref. No.: Date: Ref. No. of Previous Submission: Contract No: (1) File Reference: (2) DETAILS OF SUBMISSION To: Contract Manager s Representative Attention: From: The enclosed sample and catalogue* / certificate of origin* / technical data* / test report* / job reference* as described below have been checked for compliance with the Specifications and Drawings, and are submitted for approval. 1. General Information a. Material Description HIT HY150 Injection Adhesive b. Location: c. Specification Ref. Page: Item: d. Drawing Ref. No. e. B.Q. Ref.No.: f. Anticipated date of approval: 2. Technical Information The submitted sample has been checked against the specification and drawings as listed below:- Specification Requirements a. Brand b. Country of Origin c. Manufacturer s Name & Address d. Factory s Name & Address(es) e. Supplier (with Applicator, if any) Hilti Germany Submitted Sample (State details against each item) Hilti Corporation, FL-9494 Principality of Liechtenstein. Hilti Gmbh Ind. Ges. F. Befestigungstechnik Hiltistrasse 6, D-86916 Kaufering, Germany. Hilti (Hong Kong) Ltd Page 1 of 2 Page 2 Fen 2012

f. Appearance g. Color + h. Specification i. Manufacturer s Catalogue j. Test Report (Original/Certificated True Copy) k. Previous Job Reference l. Supplementary Information According to the sample submitted Grey Attached Attached Attached Attached NIL For and on behalf of the Contractor (Quality Control Manager) CONTRACT MANAGER S COMMENTS To: From: Contract Manager s Representative: On the basis of the sample and information given, the above sample submitted is: (1) * Approved. (2) * Not approved because Remarks: Approval does not alter the requirements of the Contract Contract Manager s Representative: Date: cc. (* Delete if appropriate) (+ For glass or vitreous mosaic tiles, the contractor is required to confirm the colour range(s) of the submitted sample, i.e. a) light and or medium; or b) dark) Page 2 of 2 Page 3 Fen 2012

SAMPLE SUBMISSION AND APPROVAL FORM Contract Title: Ref. No.: Date: Ref. No. of Previous Submission: Contract No: (1) File Reference: (2) DETAILS OF SUBMISSION To: Contract Manager s Representative Attention: From: The enclosed sample and catalogue* / certificate of origin* / technical data* / test report* / job reference* as described below have been checked for compliance with the Specifications and Drawings, and are submitted for approval. 1. General Information a. Material Description HAS-E/ER/EF Anchor Rod or HIS-N/RN (M8-M24) Anchor Sleeve b. Location: c. Specification Ref. Page: Item: d. Drawing Ref. No. e. B.Q. Ref.No.: f. Anticipated date of approval: 2. Technical Information The submitted sample has been checked against the specification and drawings as listed below:- Specification Requirements a. Brand b. Country of Origin c. Manufacturer s Name & Address d. Factory s Name & Address(es) e. Supplier (with Applicator, if any) Hilti Republic of China Submitted Sample (State details against each item) Hilti Corporation, FL-9494 Principality of Liechtenstein. Hilti (China Zhangjiang) Co. Ltd., Yongping Road South, Zhangjiang Development Zone, 524022 Zhangjiang, Guangdong Province, China. Page 1 of 2 Page 4 Fen 2012

f. Appearance g. Color + h. Specification i. Manufacturer s Catalogue j. Test Report (Original/Certificated True Copy) k. Previous Job Reference l. Supplementary Information Hilti (Hong Kong) Ltd According to the sample submitted Nil Attached Attached Attached Attached NIL For and on behalf of the Contractor (Quality Control Manager) CONTRACT MANAGER S COMMENTS To: From: Contract Manager s Representative: On the basis of the sample and information given, the above sample submitted is: (1) * Approved. (2) * Not approved because Remarks: Approval does not alter the requirements of the Contract Contract Manager s Representative: Date: cc. (* Delete if appropriate) (+ For glass or vitreous mosaic tiles, the contractor is required to confirm the colour range(s) of the submitted sample, i.e. a) light and or medium; or b) dark) Page 2 of 2 Page 5 Fen 2012

SAMPLE SUBMISSION AND APPROVAL FORM Contract Title: Ref. No.: Date: Ref. No. of Previous Submission: Contract No: (1) File Reference: (2) DETAILS OF SUBMISSION To: Contract Manager s Representative Attention: From: The enclosed sample and catalogue* / certificate of origin* / technical data* / test report* / job reference* as described below have been checked for compliance with the Specifications and Drawings, and are submitted for approval. 1. General Information a. Material Description HAS-E/ER/EF (M27-M39) Anchor Rod b. Location: c. Specification Ref. Page: Item: d. Drawing Ref. No. e. B.Q. Ref.No.: f. Anticipated date of approval: 2. Technical Information The submitted sample has been checked against the specification and drawings as listed below:- Specification Requirements a. Brand b. Country of Origin c. Manufacturer s Name & Address d. Factory s Name & Address(es) e. Supplier (with Applicator, if any) Hilti Hungary Submitted Sample (State details against each item) Hilti Corporation, FL-9494 Principality of Liechtenstein. Hilti Werkzeug Gmbh., Kecskemet / Szt. Istvan 17, Hungary. Hilti (Hong Kong) Ltd Page 1 of 2 Page 6 Fen 2012

f. Appearance g. Color + h. Specification i. Manufacturer s Catalogue j. Test Report (Original/Certificated True Copy) k. Previous Job Reference l. Supplementary Information According to the sample submitted Nil Attached Attached Attached Attached NIL For and on behalf of the Contractor (Quality Control Manager) CONTRACT MANAGER S COMMENTS To: From: Contract Manager s Representative: On the basis of the sample and information given, the above sample submitted is: (1) * Approved. (2) * Not approved because Remarks: Approval does not alter the requirements of the Contract Contract Manager s Representative: Date: cc. (* Delete if appropriate) (+ For glass or vitreous mosaic tiles, the contractor is required to confirm the colour range(s) of the submitted sample, i.e. a) light and or medium; or b) dark) Page 2 of 2 Page 7 Fen 2012

SAMPLE SUBMISSION AND APPROVAL FORM Contract Title: Ref. No.: Date: Ref. No. of Previous Submission: Contract No: (1) File Reference: (2) DETAILS OF SUBMISSION To: Contract Manager s Representative Attention: From: The enclosed sample and catalogue* / certificate of origin* / technical data* / test report* / job reference* as described below have been checked for compliance with the Specifications and Drawings, and are submitted for approval. 1. General Information a. Material Description HAS-HCR Anchor Rod b. Location: c. Specification Ref. Page: Item: d. Drawing Ref. No. e. B.Q. Ref.No.: f. Anticipated date of approval: 2. Technical Information The submitted sample has been checked against the specification and drawings as listed below:- Specification Requirements a. Brand b. Country of Origin c. Manufacturer s Name & Address d. Factory s Name & Address(es) e. Supplier (with Applicator, if any) Hilti Germany Submitted Sample (State details against each item) Hilti Corporation, FL-9494 Principality of Liechtenstein. Hilti Gmbh. Ind. Ges. F. Befestigungstechnik, Hiltistrasse 6, D-86916 Kaufering, Germany. Hilti (Hong Kong) Ltd Page 1 of 2 Page 8 Fen 2012

f. Appearance g. Color + h. Specification i. Manufacturer s Catalogue j. Test Report (Original/Certificated True Copy) k. Previous Job Reference l. Supplementary Information According to the sample submitted Nil Attached Attached Attached Attached NIL For and on behalf of the Contractor (Quality Control Manager) CONTRACT MANAGER S COMMENTS To: From: Contract Manager s Representative: On the basis of the sample and information given, the above sample submitted is: (1) * Approved. (2) * Not approved because Remarks: Approval does not alter the requirements of the Contract Contract Manager s Representative: Date: cc. (* Delete if appropriate) (+ For glass or vitreous mosaic tiles, the contractor is required to confirm the colour range(s) of the submitted sample, i.e. a) light and or medium; or b) dark) Page 2 of 2 Page 9 Fen 2012

Anchoring Systems Injection adhesive HIT-HY 150 Applications Suitable to achieve high loads in concrete and stone For fixing post-installed rebar and anchor rod up to M24 For fastening the hand rail and fencing For repair mortar Base Material Concrete Hard natural stone Material 2-component ready mix epoxy resin (styrene-free) Curing time Temperature of the base material Working time Curing time 40 C 2 min. 40 min. 30 C 4 min. 50 min. 20 C 6 min. 90 min. 10 C 20 min. 2 hours Advantages For fastenings without expansion pressure User-friendly and odourless (styrene-free) Fast curing resin to increase the productivity Foil pack design reduces disposal cost With NSF and WRAS approvals for use in contact with drinking water 7 Approvals: (Rebar) Installation procedures 2 3 4 5 6 7 8 3x/2x Drill the hole. 9 10 Clean the drilled hole. 11 12 Open the cartridge cap, insert it into the holder and screw the mixer on it. Put the cartridge into the dispenser. Throw away (must) first 3 trigger pulls for 500 ml cartridge or 2 trigger pulls for 330 ml cartridge. Release dispenser to stop the grout flowing. Inject the mortar from bottom to the top of the hole. (Approx. 2/3 of the hole depth). Insert the anchor rod slowly by turning it into the mortar up to the required depth. Fix the work piece after the grout is cured. Ordering Order designation Content (ml) Package (pcs) Including Item No. FOIL PACK RE HIT-HY 150 / 500 / 2 500 20 2 Mixers 00338973 FOIL PACK RE HIT-HY 150 / 330 / 2 330 20 2 Mixers 00315959 HIT-M mixer - 100-00068156 Page 10 Fen 2012 178 Customer Hotline: Hong Kong 8228 8118 Macau 00800 8228 8118 (Mon - Fri 8:30 am - 6:00 pm / Sat 8:30 am - 1:00 pm) Hilti online: www.hilti.com.hk

Anchoring Systems Anchor rod HIT-HY 150 with HAS-E / HIT-V h nom Materials Steel strength grade 5.8 for M8 to M24 galvanized at least 5µm Steel strength grade 5.8 for M8 to M24, hot dip galv. to 45µm A4-70 stainless steel (M8-M24) High corrosion resistance (HCR) (M8-M24) d o h 1 t fix d f Approvals: (Threaded Rod) Technical data Recommended load (kn), non-cracked concrete at 25N/mm², safety factor( )=3 Model Size M8 M10 M12 M16 M20 M24 HIT-HY 150 + HAS-E / -EF / HIT-V HIT-HY 150 + HAS-ER / -HCR / HIT-V-R Tensile Load, Nrec 5.7 8.7 12.7 18.8 30.3 42.2 Shear Load, Vrec 2.8 4.3 6.3 12.0 18.7 26.7 Tensile Load, Nrec 7.7 12.3 17.7 18.8 30.3 42.2 Shear Load, Vrec 4.0 6.3 9.0 17.0 26.3 37.3 Remarks: 1) All the data applies to no edge distance, spacing and other influences 2) For detail design method, please refer to Fastening Technology Manual 3) HAS-HCR anchor rod are only up to M24 only Anchor rod HAS-E Anchor rod HIT-V page 189 page 186 Anchor sleeve HIT-HY 150 with HIS-N h s Materials Carbon steel galvanized at least 5µm (M8-M20) A4-70 stainless steel (M8-M20) d o d f h nom h 1 Technical data Recommended load (kn), non-cracked concrete at 25N/mm², safety factor( )=3 Model Size M8 M10 M12 M16 M20 HIT-HY 150 + HIS-N HIT-HY 150 + HIS-RN Remarks: 1) All the data applies to no edge distance, spacing and other influences 2) For detail design method, please refer to Fastening Technology Manual Tensile Load, Nrec 8.3 13.3 20.0 39.7 36.3 Shear Load, Vrec 4.3 7.7 13.0 19.7 18.3 Tensile Load, Nrec 8.7 13.3 19.7 36.7 46.7 Shear Load, Vrec 4.3 6.7 10.0 18.3 27.7 Anchor sleeve HIS-N page 191 Page 11 Fen 2012 179 Customer Hotline: Hong Kong 8228 8118 Macau 00800 8228 8118 (Mon - Fri 8:30 am - 6:00 pm / Sat 8:30 am - 1:00 pm) Hilti online: www.hilti.com.hk

Anchoring Systems Anchor rod HVU with HAS-E Materials Steel strength grade 5.8 and 8.8 for M8 to M24 and M27 to M39 respectively, galvanized at least 5µm Steel strength grade 5.8 and 8.8 for M8 to M24 and M27 to M39 respectively, hot dip galv. to 45µm A4-70 and A4-50 stainless steel for M8 to M24 and M27 to M39 respectively. High corrosion resistance (HCR) (M8-M24) d o h 1 d f t fix HAS-E Programme HAS-E galvanized version (min. 5µm) Drill bit Tighten. Max. Clear- Width Thread nom. Min. hole Anchorage torque fasten. ance across HVU dia. dia., do depth, h1 depth, hnom Tinst thk. tfix hole, df flats, Sw Capsule Package Order designation Item no. (mm) (mm) (mm) (mm) (Nm) (mm) (mm) (pcs) M8 10 85 80 15 14 9 13 HVU M8x80 20 HAS-E M8x80/14 00332219 M8 10 85 80 15 54 9 13 HVU M8x80 10 HAS-E M8x80/54 00333099 M10 12 95 90 30 21 12 17 HVU M10x90 20 HAS-E M10x90/21 00332220 M10 12 95 90 30 61 12 17 HVU M10x90 10 HAS-E M10x90/61 00333100 M10 12 95 90 30 81 12 17 HVU M10x90 10 HAS-E M10x90/81 00333101 M12 14 115 110 50 28 14 19 HVU M12x110 20 HAS-E M12x110/28 00332221 M12 14 115 110 50 88 14 19 HVU M12x110 10 HAS-E M12x110/88 00333102 M12 14 115 110 50 128 14 19 HVU M12x110 10 HAS-E M12x110/128 00333103 M12 14 115 110 50 168 14 19 HVU M12x110 10 HAS-E M12x110/168 00333104 M16 18 130 125 100 20 18 24 HVU M16x125 10 HAS-E M16x125/20 00333105 M16 18 130 125 100 38 18 24 HVU M16x125 20 HAS-E M16x125/38 00332222 M16 18 130 125 100 108 18 24 HVU M16x125 10 HAS-E M16x125/108 00333106 M16 18 130 125 100 148 18 24 HVU M16x125 10 HAS-E M16x125/148 00333107 M16 18 130 125 100 198 18 24 HVU M16x125 10 HAS-E M16x125/198 00333108 M16 18 130 125 100 348 18 24 HVU M16x125 10 HAS-E M16x125/348 00333109 M20 24 175 170 160 48 22 30 HVU M20x170 10 HAS-E M20x170/48 00332223 M20 24 175 170 160 68 22 30 HVU M20x170 10 HAS-E M20x170/68 00333110 M20 24 175 170 160 108 22 30 HVU M20x170 10 HAS-E M20x170/108 00333111 M20 24 175 170 160 158 22 30 HVU M20x170 10 HAS-E M20x170/158 00333112 M20 24 175 170 160 208 22 30 HVU M20x170 10 HAS-E M20x170/208 00333113 M24 28 215 210 240 54 26 36 HVU M24x210 10 HAS-E M24x210/54 00332224 M27 30 250 240 270 60 30 41 HVU M27x240 4 HAS-E M27x240/60 00333114 M30 35 280 270 300 70 33 46 HVU M30x270 4 HAS-E M30x270/70 00333115 M33 37 310 300 1200 80 36 50 HVU M33x300 4 HAS-E M33x300/80 00333116 M36 40 340 330 1500 90 39 55 HVU M36x330 2 HAS-E M36x330/90 00333117 M39 42 370 360 1800 100 42 59 HVU M39x360 2 HAS-E M39x360/100 00333118 HAS-EF hot dip galvanized version (min. 45µm) M8 10 85 80 15 14 9 13 HVU M8x80 20 HAS-EF M8x80/14 00333143 M8 10 85 80 15 54 9 13 HVU M8x80 10 HAS-EF M8x80/54 00333144 M10 12 95 90 30 21 12 17 HVU M10x90 20 HAS-EF M10x90/21 00333145 M10 12 95 90 30 61 12 17 HVU M10x90 10 HAS-EF M10x90/61 00333146 M10 12 95 90 30 81 12 17 HVU M10x90 10 HAS-EF M10x90/81 00333147 M12 14 115 110 50 28 14 19 HVU M12x110 10 HAS-EF M12x110/28 00333148 M12 14 115 110 50 88 14 19 HVU M12x110 20 HAS-EF M12x110/88 00333149 M12 14 115 110 50 128 14 19 HVU M12x110 10 HAS-EF M12x110/128 00333150 M12 14 115 110 50 168 14 19 HVU M12x110 10 HAS-EF M12x110/168 00333151 M16 18 130 125 100 20 18 24 HVU M16x125 10 HAS-EF M16x125/20 00333152 M16 18 130 125 100 38 18 24 HVU M16x125 10 HAS-EF M16x125/38 00333153 M16 18 130 125 100 108 18 24 HVU M16x125 10 HAS-EF M16x125/108 00333154 M16 18 130 125 100 148 18 24 HVU M16x125 10 HAS-EF M16x125/148 00333155 M16 18 130 125 100 198 18 24 HVU M16x125 10 HAS-EF M16x125/198 00333156 M16 18 130 125 100 348 18 24 HVU M16x125 10 HAS-EF M16x125/348 00333157 M20 24 175 170 160 48 22 30 HVU M20x170 10 HAS-EF M20x170/48 00333158 M20 24 175 170 160 68 22 30 HVU M20x170 10 HAS-EF M20x170/68 00333159 M20 24 175 170 160 108 22 30 HVU M20x170 10 HAS-EF M20x170/108 00333160 M20 24 175 170 160 158 22 30 HVU M20x170 10 HAS-EF M20x170/158 00333161 M20 24 175 170 160 208 22 30 HVU M20x170 10 HAS-EF M20x170/208 00333162 M24 28 215 210 240 54 26 36 HVU M24x210 10 HAS-EF M24x210/54 00333163 M27 30 250 240 270 60 30 41 HVU M27x240 4 HAS-EF M27x240/60 00333164 M30 35 280 270 300 70 33 46 HVU M30x270 4 HAS-EF M30x270/70 00333165 M33 37 310 300 1200 80 36 50 HVU M33x300 4 HAS-EF M33x300/80 00333166 M36 40 340 330 1500 90 39 55 HVU M36x330 2 HAS-EF M36x330/90 00333167 M39 42 370 360 1800 100 42 59 HVU M39x360 2 HAS-EF M39x360/100 00333168 Special Request 189 Customer Hotline: Hong Kong 8228 8118 Macau 00800 8228 8118 (Mon - Fri 8:30 am - 6:00 pm / Sat 8:30 am - 1:00 pm) Hilti online: www.hilti.com.hk Page 12 Fen 2012

Anchoring Systems HAS-ER A4 stainless steel version Drill bit Anchorage Tighten. Max. Clear- Width Thread nom. Min. hole depth torque fasten. ance across HVU dia. dia., do depth, h1 hnom Tinst thk. tfix hole, df flats, Sw Capsule Package (mm) (mm) (mm) (mm) (Nm) (mm) (mm) (pcs) Order designation Item no. M8 10 85 80 15 14 9 13 HVU M8x80 20 HAS-ER M8x80/14 00333119 M8 10 85 80 15 54 9 13 HVU M8x80 10 HAS-ER M8x80/54 00333120 M8 10 85 80 15 114 9 13 HVU M8x80 10 HAS-ER M8x80/114 00333121 M10 12 95 90 30 21 12 17 HVU M10x90 20 HAS-ER M10x90/21 00333122 M10 12 95 90 30 61 12 17 HVU M10x90 10 HAS-ER M10x90/61 00333123 M10 12 95 90 30 81 12 17 HVU M10x90 10 HAS-ER M10x90/81 00333124 M10 12 95 90 30 111 12 17 HVU M10x90 10 HAS-ER M10x90/111 00333125 M12 14 115 110 50 28 14 19 HVU M12x110 20 HAS-ER M12x110/28 00333126 M12 14 115 110 50 88 14 19 HVU M12x110 10 HAS-ER M12x110/88 00333127 M12 14 115 110 50 128 14 19 HVU M12x110 10 HAS-ER M12x110/128 00333128 M12 14 115 110 50 168 14 19 HVU M12x110 10 HAS-ER M12x110/168 00333129 M16 18 130 125 100 20 18 24 HVU M16x125 10 HAS-ER M16x125/20 00333130 M16 18 130 125 100 38 18 24 HVU M16x125 20 HAS-ER M16x125/38 00333131 M16 18 130 125 100 108 18 24 HVU M16x125 10 HAS-ER M16x125/108 00333132 M16 18 130 125 100 148 18 24 HVU M16x125 10 HAS-ER M16x125/148 00333133 M16 18 130 125 100 198 18 24 HVU M16x125 10 HAS-ER M16x125/198 00333134 M20 24 175 170 160 48 22 30 HVU M20x170 10 HAS-ER M20x170/48 00333135 M20 24 175 170 160 108 22 30 HVU M20x170 10 HAS-ER M20x170/108 00333136 M24 28 215 210 240 54 26 36 HVU M24x210 10 HAS-ER M24x210/54 00333137 M27 30 250 240 270 60 30 41 HVU M27x240 4 HAS-ER M27x240/60 00333138 M30 35 280 270 300 70 33 46 HVU M30x270 4 HAS-ER M30x270/70 00333139 M33 37 310 300 1200 80 36 50 HVU M33x300 4 HAS-ER M33x300/80 00333140 M36 40 340 330 1500 90 39 55 HVU M36x330 2 HAS-ER M36x330/90 00333141 M39 42 370 360 1800 100 42 59 HVU M39x360 2 HAS-ER M39x360/100 00333142 HAS-HCR high corrosion resistance material M8 10 85 80 15 14 9 13 HVU M8x80 20 HAS-HCR M8x80/14 00229504 M10 12 95 90 30 21 12 17 HVU M10x90 10 HAS-HCR M10x90/21 00229505 M12 14 115 110 50 28 14 19 HVU M12x110 10 HAS-HCR M12x110/28 00229506 M16 18 130 125 100 38 18 24 HVU M16x125 5 HAS-HCR M16x125/38 00229507 M20 24 175 170 160 48 22 30 HVU M20x170 5 HAS-HCR M20x170/48 00229508 M24 28 215 210 240 54 26 36 HVU M24x210 5 HAS-HCR M24x210/54 00229509 7 Required tools Anchor TE adapter Package Square socket Package Anchor description Order designation (pcs) Item no. Order designation (pcs) Item no. HVU M8 + HAS-E / -EF / -ER M8 TE-C 1/2" 1 00032220 Socket 13x1/2" (M8) 1 00060186 HVU M10 + HAS-E / -EF / -ER M10 TE-C 1/2" 1 00032220 Socket 17x1/2" (M10) 1 00060187 HVU M12 + HAS-E / -EF / -ER M12 TE-C 1/2" 1 00032220 Socket 19x1/2" (M12) 1 00060188 HVU M16 + HAS-E / -EF / -ER M16 TE-FY 3/4" 1 00032221 Socket 24x3/4" (M16) 1 00060190 HVU M20 + HAS-E / -EF / -ER M20 TE-FY 3/4" 1 00032221 Socket 30x3/4" (M20) 1 00060191 HVU M24 + HAS-E / -EF / -ER M24 TE-FY 3/4" 1 00032221 Socket 36x3/4" (M24) 1 03403094 HVU M27 + HAS-E / -EF / -ER M27 BU 3/4" 1 00308848 Socket 41x3/4" (M27) - - HVU M30 + HAS-E / -EF / -ER M30 BU 3/4" 1 00308848 Socket 46x3/4" (M30) - - HVU M33 + HAS-E / -EF / -ER M33 BU 3/4" 1 00308848 Socket 50x3/4" (M33) - - HVU M36 + HAS-E / -EF / -ER M36 BU 3/4" 1 00308848 Socket 55x3/4" (M36) - - HVU M39 + HAS-E / -EF / -ER M39 BU 3/4" 1 00308848 Socket 59x3/4" (M39) - - Anchor HAS-E Setting tool Package Anchor description Order designation (pcs) Item no. HVU M8 + HAS-E / -EF / -ER M8 TE-C-E M8 1 00369223 HVU M10 + HAS-E / -EF / -ER M10 TE-C-E M10 1 00369224 HVU M12 + HAS-E / -EF / -ER M12 TE-C-E M12 1 00369225 HVU M16 + HAS-E / -EF / -ER M16 TE-C-E M16 1 00369226 HVU M16 + HAS-E / -EF / -ER M16 TE-Y-E M16 1 00369227 HVU M20 + HAS-E / -EF / -ER M20 TE-Y-E M20 1 00369228 HVU M24 + HAS-E / -EF / -ER M24 TE-Y-E M24 1 00369229 Special Request Customer Hotline: Hong Kong 8228 8118 Macau 00800 8228 8118 (Mon - Fri 8:30 am - 6:00 pm / Sat 8:30 am - 1:00 pm) Hilti online: www.hilti.com.hk Page 13 Fen 2012 190

Anchoring Systems Anchor sleeve HVU with HIS-N Materials Carbon steel galvanized at least 5µm (M8-M20) A4-70 stainless steel (M8-M20) d o h s d f Technical data Recommended load (kn), non-cracked concrete at 25N/mm², safety factor( )=3 HVU + HIS-N Model Size M8 M10 M12 M16 M20 HVU + HIS-RN Tensile Load, Nrec 8.3 13.3 20.0 31.7 36.3 Shear Load, Vrec 4.3 7.7 13.0 19.7 18.3 Tensile Load, Nrec 8.3 13.3 19.7 31.7 46.7 Shear Load, Vrec 4.3 6.7 10.0 18.3 27.7 Remarks: 1) All the data applies to no edge distance, spacing and other influences 2) For detail design method, please refer to Fastening Technology Manual h 1 Installation procedures 6 Drill the anchor hole. Clean the drilled hole with the blow-out pump. Insert the adhesive capsule (HVU) into the hole. Set the anchor sleeve (HIS-N or HIS-RN) by using hammer drill with HIS-S setting tools such that it is flush with the base material surface. Leave the setting tools or rod adapter remaining attached and remove it only the cure time was passed. Put the part to be fastened in place and fasten the part using bolt or others. HIS-N Programme: HIS-N galvanized version (min. 5µm) Screw Drill bit Tighten. depth, Clear- Thread nom. Min. hole Anchorage torque hs (min) / ance dia. dia., do depth,h1 depth, hnom Tinst hs (max) hole, df HVU capsule Package Order designation Item no. (mm) (mm) (mm) (mm) (Nm) (mm) (mm) (pcs) M8 14 95 90 15 8 / 20 9 HVU M10x90 10 HIS-N M8x90 00258015 M10 18 115 110 28 10 / 25 12 HVU M12x110 10 HIS-N M10x110 00258016 M12 22 130 125 50 12 / 30 14 HVU M16x125 5 HIS-N M12x125 00258017 M16 28 175 170 85 16 / 40 18 HVU M20x170 5 HIS-N M16x170 00258018 M20 32 210 205 170 20 / 50 22 HVU M24x210 5 HIS-N M20x205 00258019 HIS-RN A4 stainless steel M8 14 95 90 12 8 / 20 9 HVU M10x90 10 HIS-RN M8x90 00258024 M10 18 115 110 23 10 / 25 12 HVU M12x110 10 HIS-RN M10x110 00258025 M12 22 130 125 40 12 / 30 14 HVU M16x125 5 HIS-RN M12x125 00258026 M16 28 175 170 70 16 / 40 18 HVU M20x170 5 HIS-RN M16x170 00258027 M20 32 210 205 130 20 / 50 22 HVU M24x210 5 HIS-RN M20x205 00258028 Required tools Anchor TE adapter Package Square socket Package Setting tools Package Anchor description Order designation (pcs) Item no. Order designation (pcs) Item no. Order designation (pcs) Item no. HVU M10 + HIS-N / -RN M8 TE-C 1/2" 1 00032220 Socket 13x1/2" (M8) 1 00060186 HIS-S M8 1 00045964 HVU M12 + HIS-N / -RN M10 TE-C 1/2" 1 00032220 Socket 17x1/2" (M10) 1 00060187 HIS-S M10 1 00045965 HVU M16 + HIS-N / -RN M12 TE-C 1/2" 1 00032220 Socket 19x1/2" (M12) 1 00060188 HIS-S M12 1 00045966 HVU M20 + HIS-N / -RN M16 TE-FY 3/4" 1 00032221 Socket 24x3/4" (M16) 1 00060190 HIS-S M16 1 00045967 HVU M24 + HIS-N / -RN M20 TE-FY 3/4" 1 00032221 Socket 30x3/4" (M20) 1 00060191 HIS-S M20 1 00045968 Special Request 191 Customer Hotline: Hong Kong 8228 8118 Macau 00800 8228 8118 (Mon - Fri 8:30 am - 6:00 pm / Sat 8:30 am - 1:00 pm) Hilti online: www.hilti.com.hk Page 14 Fen 2012

Anchoring Systems Cordless dispenser ED 3500-A Applications Injection of Hilti HIT adhesive mortar for fastening anchor rods and rebars in concrete, masonry and stone Advantages Specially designed for repetitive, heavy use even in difficult-to-reach locations Quicker and less tiring to use - for higher productivity Provides the power and efficiency of a pneumatic dispenser without need for a compressor Effortless injection even at low temperatures and in deep holes Low weight for maximum operating comfort Technical data Power source type Dispenser type Weight including batteries For use with Performance (at 20 C ; w/o extension) Battery capacity Dispensing force Model switch ED 3500-A 14.4 V / 2.6 Ah Li-ion battery Cordless electric dispenser 2.55 kg All Hilti foil packs 500 ml cartridge in 70 sec 330 ml cartridge in 45 sec Up to 80 cartridges (HIT RE500, 500 ml foil packs) Max. 3000 N Off position / continuous feed / single stroke FLEET MANAGEMENT 7 Ordering Order designation Package content Item No. ED 3500-A cordless dispenser kit ED 3500-A cordless dispenser basic kit ED 3500-A cordless dispenser, safety goggles, round brushes (13, 18, 28 mm dia.), blow-out pump, foil pack holder (x2), operating instructions (ED 3500 and charger), supplied in a Hilti toolbox ED 3500-A cordless dispenser, safety goggles, foil pack holder (x1), operating instructions, supplied in a cardboard box 00360862 00360863 Accessories ED 3500-A Order designation Item No. C4/36 ACS (230V) standard battery charger in a cardboard box 00272434 with operating instruction and safety precautions B14 battery (2.6Ah Li-ion) in a cardboard box 00273114 Special Request Customer Hotline: Hong Kong 8228 8118 Macau 00800 8228 8118 (Mon - Fri 8:30 am - 6:00 pm / Sat 8:30 am - 1:00 pm) Hilti online: www.hilti.com.hk Page 15 Fen 2012 180

Anchoring Systems HIT System Injection of Hilti HIT adhsive mortar for fastening anchor rods and rebars in concrete, masonry and stone. Ordering Order designation Package content Item No. Tool kit MD2500 (500ml) Case, dispenser, 2 foil pack holders, blow-out pump, brushes dia. 13, 18 & 28 mm and protective google 00369220 Tool kit MD2000 (330ml) Case, dispenser, 2 foil pack holders, blow-out pump, brushes dia. 13, 18 & 28 mm and protective google 00229155 MD2500 dispenser (500ml) Include 1 dispenser and 1 foil pack holder 00338853 MD2000 dispenser (330ml) Include 1 dispenser and 1 foil pack holder 00229154 Accessories HIT System Order designation Item No. Foil pack holder (500 ml) 3:1 00339477 Foil pack holder (330 ml) 3:1 00229170 Blow out pump 00060579 Brush with grip dia 13mm HG 00229133 Brush with grip dia 18mm HG 00229134 Brush with grip dia 28mm HG 00229135 Brush with GA dia 18mm* GA 00229136 Brush with GA dia 28mm* GA 00229137 Brush with GA dia 38mm* GA 00229673 Brush with GA dia 50mm* GA 00229674 Brush extension with GA* 00229138 Brush adapter (middle section)* 00238727 Overhead wedge HIT-OHW 00387550 Overhead cup ( 8-20 mm) # 00387551 Overhead cup ( 20 mm above) # 00387552 # Rebar or thread rod diameter * GA= thread connection Special Request 181 Customer Hotline: Hong Kong 8228 8118 Macau 00800 8228 8118 (Mon - Fri 8:30 am - 6:00 pm / Sat 8:30 am - 1:00 pm) Hilti online: www.hilti.com.hk Page 16 Fen 2012

Anchoring Systems Accessories For long embedment application HIT system Order designation Item No. HIT Protective goggles 00005205 HIT-DL 20 Air nozzle (dia.20 mm) 00371719 HIT-DL 25 Air nozzle (dia.24 mm) 00371720 HIT-DL 32 Air nozzle (dia.32 mm) 00371721 HIT-DRS Dust removal system 00362323 TE-Y RBS Holder for brush extension 00263439 TE-C RBS Holder for brush extension 00263437 HIT-RBS 10/0.7 Bursh extension 00336645 for round steel brush (0.7 m length) HIT-RB 20 Round steel brush (dia. 20 mm) 00336552 HIT-RB 25 Round steel brush (dia. 25 mm) 00336553 HIT-RB 30 Round steel brush (dia. 30 mm) 00380920 HIT-RB 40 Round steel brush (dia. 40 mm) 00382260 HIT-RB 47 Round steel brush (dia. 47 mm) 00382264 HIT-VL K Coupler for injection extensions 00335021 HIT-SZ 20 Piston Plug (dia. 20 mm) 00335026 HIT-SZ 25 Piston Plug (dia. 25 mm) 00335027 HIT-SZ 30 Piston Plug (dia. 30 mm) 00380925 HIT-SZ 40 Piston Plug (dia. 40 mm) 00380927 HIT-SZ 47 Piston Plug (dia. 47 mm) 00380930 7 Special Request Customer Hotline: Hong Kong 8228 8118 Macau 00800 8228 8118 (Mon - Fri 8:30 am - 6:00 pm / Sat 8:30 am - 1:00 pm) Hilti online: www.hilti.com.hk Page 17 Fen 2012 182

Page 18 Fen 2012 Hilti HIT-HY 150 with HAS Basic loading data (for a single anchor) All data in this section applies to For details see Simplified design method - Correct setting (See setting instruction) - No edge distance and spacing influence - Steel failure - Base material thickness, as specified in the table - One typical embedment depth, as specified in the table - One anchor material, as specified in the tables - Concrete C 20/25, fck,cube = 25 N/mm² - Temperate range I (min. base material temperature -40 C, max. long term/short term base material temperature: +24 C/40 C) - Installation temperature range -5 C to +40 C Embedment depth a) and base material thickness for the basic loading data. Characteristic resistance, design resistance, recommended loads. Anchor size M8 M10 M12 M16 M20 M24 Typical embedment depth hef [mm] 80 90 110 125 170 210 Base material thickness h [mm] 110 120 140 165 220 270 a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be calculated according to the simplified design method. Characteristic resistance: non-cracked concrete C 20/25, anchor HAS Anchor size M8 M10 M12 M16 M20 M24 Tensile NRk HAS-E a) [kn] 17.0 26.0 38.0 56.5 90.8 126.7 Shear VRk HAS-E a) [kn] 8.5 13.0 19.0 36.0 56.0 80.0 Tensile NRk HAS-ER (A4) [kn] 23.0 37.0 53.0 56.5 90.8 126.7 Shear VRk HAS-ER (A4) [kn] 12.0 19.0 27.0 51.0 79.0 112.0 Design resistance: non-cracked concrete C 20/25, anchor HAS Anchor size M8 M10 M12 M16 M20 M24 Tensile NRk HAS-E a) [kn] 11.3 17.3 25.3 26.9 43.2 60.3 Shear VRk HAS-E a) [kn] 6.8 10.4 15.2 28.8 44.8 64.0 Tensile NRk HAS-ER (A4) [kn] 12.3 17.3 25.3 26.9 43.2 60.3 Shear VRk HAS-ER (A4) [kn] 7.7 12.2 17.3 32.7 50.6 71.8 Recommended loads b) : non-cracked concrete C 20/25, anchor / HAS Anchor size M8 M10 M12 M16 M20 M24 Tensile NRk HAS-E a) [kn] 5.7 8.7 12.7 18.8 30.3 42.2 Shear VRk HAS-E a) [kn] 2.8 4.3 6.3 12.0 18.7 26,7 Tensile NRk HAS-ER (A4) [kn] 7.7 12.3 17.7 18.8 30.3 42.2 Shear VRk HAS-ER (A4) [kn] 4.0 6.3 9.0 17.0 26.3 37.3 a) The standard delivery program for HAS-E anchor rod: Grade 5.8 for HAS-E M8-M24. b) With overall global safety factor = 3. The recommended loads vary according to the safety factor requirement from national regulations. 2 / 2011 267 Hilti HIT-HY 150 with HAS Hilti HIT-HY 150 with HIT-V / HAS-(E) / HAS-(E)R Injection mortar system Benefits Hilti HIT-HY 150 330 ml foil pack (also available as 500 ml and 1400 ml foil pack) Static mixer HAS-E rods HAS-E-R rods HIT-V rods HIT-V-R rods HIT-V-HCR rods - suitable for non-cracked concrete - suitable for dry and water saturated concrete - high loading capacity - rapid curing - small edge distance and anchor spacing possible - large diameter applications - high corrosion resistant - in service temperature range up to 120 C short term/72 C long term - manual cleaning for anchor size M8 to M16 and embedment depth hef 10d - embedment depth range M8: 60 to 160 mm M30: 120 to 600 mm Concrete Small edge distance and spacing Variable embedment depth Fire resistance Corrosion resistance High corrosion resistance European Technical Approval CE conformity Hilti anchor design software Approvals / certificates Description Authority / Laboratory No. / date of issue European technical approval a) DIBt, Berlin ETA-05/0051 / 2008-10-22 Fire test report MFPA Braunschweig UB 3027 / 0274-6 / 1994-06-30 Assessment report (fire) warringtonfire WF 166402 / 2007-10-26 a) All data given in this section according ETA-05/0051 issue 2008-10-22. 266 2 / 2011

Page 19 Fen 2012 Hilti HIT-HY 150 with HAS Material quality Part Material Threaded rod HIT-V(F), HAS 5.8: M8 M24 Threaded rod HIT-V-R, HAS-R Threaded rod HIT-V-HCR, HAS-HCR Washer ISO 7089 Nut EN ISO 4032 Strength class 5.8, EN ISO 898-1, A5 > 8% ductile steel galvanized 5 μm, EN ISO 4042 (F) hot dipped galvanized 45 μm, EN ISO 10684 Stainless steel grade A4, A5 > 8% ductile strength class 70 for M24 and class 50 for M27 to M30, EN ISO 3506-1, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 High corrosion resistant steel, EN ISO 3506-1, EN 10088: 1.4529; 1.4565 strength M20: Rm = 800 N/mm², Rp 0.2 = 640 N/mm², A5 > 8% ductile M24: Rm = 700 N/mm², Rp 0.2 = 400 N/mm², A5 > 8% ductile Steel galvanized, EN ISO 4042; hot dipped galvanized, EN ISO 10684 Stainless steel, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 High corrosion resistant steel, EN 10088: 1.4529; 1.4565 Strength class 8, ISO 898-2 steel galvanized 5 μm, EN ISO 4042 hot dipped galvanized 45 μm, EN ISO 10684 Strength class 70, EN ISO 3506-2, stainless steel grade A4, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 Strength class 70, EN ISO 3506-2, high corrosion resistant steel, EN 10088: 1.4529; 1.4565 Anchor dimensions Anchor size M8 M10 M12 M16 M20 M24 Anchor rod HAS, HAS-R, HAS-HCR HAS-E, HAS-E-R Embedment depth hef [mm] 80 90 110 125 170 210 Anchor rod HIT-V, HIT-V-R, HIT-V-HCR Anchor rods HIT-V (-R / -HCR) are available in variable length Setting installation equipment Anchor size M8 M10 M12 M16 M20 M24 Rotary hammer TE 2 TE 16 TE 40 TE 70 Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser 2 / 2011 269 M8x80 M10x90 M12x110 M16x125 M20x170 M24x210 Hilti HIT-HY 150 with HAS Service temperature range Hilti HIT-HY 150 injection mortar may be applied in the temperature ranges given below. An elevated base material temperature may lead to a reduction of the design bond resistance. Temperature range Base material temperature Maximum long term base material temperature Maximum short term base material temperature Temperature range I -40 C to +40 C +24 C +40 C Temperature range II -40 C to +80 C +50 C +80 C Temperature range III -40 C to +120 C +72 C +120 C Max short term base material temperature Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of diurnal cycling. Max long term base material temperature Long-term elevated base material temperatures are roughly constant over significant periods of time. Materials Mechanical properties of HIT-V / HAS Anchor size M8 M10 M12 M16 M20 M24 Nominal tensile strength fuk Yield strength fyk Stressed cross-section As Moment of resistance W HIT-V/HAS 5.8 [N/mm²] 500 500 500 500 500 500 HIT-V/HAS 8.8 [N/mm²] 800 800 800 800 800 800 HIT-V/HAS -R [N/mm²] 700 700 700 700 700 700 HIT-V/HAS -HCR [N/mm²] 800 800 800 800 800 700 HIT-V/HAS 5.8 [N/mm²] 400 400 400 400 400 400 HIT-V/HAS 8.8 [N/mm²] 640 640 640 640 640 640 HIT-V/HAS -R [N/mm²] 450 450 450 450 450 450 HIT-V/HAS -HCR [N/mm²] 600 600 600 600 600 400 HAS [mm²] 32,8 52,3 76,2 144 225 324 HIT-V [mm²] 36,6 58,0 84,3 157 245 353 HAS [mm³] 27,0 54,1 93,8 244 474 809 HIT-V [mm³] 31,2 62,3 109 277 541 935 268 2 / 2011

Page 20 Fen 2012 Hilti HIT-HY 150 with HAS Working time, Curing time Temperature of the base material TBM Working time tgel Curing time -5 C TBM 0 C 90 min 9 h 0 C TBM 5 C 45 min 4,5 h 5 C TBM 10 C 20 min 2 h tcure a) 10 C TBM 20 C 6 min 90 min 20 C TBM 30 C 4 min 50 min 30 C TBM 40 C 2 min 40 min a) The curing time data are valid for dry anchorage base only. For water saturated anchorage bases the curing times must be doubled. Setting details Fixture Thickness tfix 2 / 2011 271 d 0 Marking of the embedment depth df Bore hole depth h0 = anchorage depth hef Thickness of concrete member h Hilti HIT-HY 150 with HAS Setting instruction Dry and water-saturated concrete, hammer drilling a) b) a) Note: Manual cleaning for element sizes d 16mm and embedment depth hef 10 d only! b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm! For detailed information on installation see instruction for use given with the package of the product. Note: Diamond cored hole is not suitable for Hilti HY-150, please use Hilti RE500. 270 2 / 2011

Page 21 Fen 2012 Hilti HIT-HY 150 with HAS Simplified design method Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in ETA-05/0051, issue 2008-10-22. Influence of concrete strength Influence of edge distance Influence of spacing Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two anchors or more than one edge distance. The influencing factors must then be considered for each edge distance and spacing. The calculated design loads are then on the save side: They will be lower than the exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design software PROFIS anchor) The design method is based on the following simplification: No different loads are acting on individual anchors (no eccentricity) The values are valid for one anchor. For more complex fastening applications please use the anchor design software PROFIS Anchor. Tension loading The design tensile resistance is the lower value of - Steel resistance: NRd,s - Combined pull-out and concrete cone resistance: NRd,p = N 0 Rd,p fb,p f1,n f2,n f3,n fh,p fre,n - Concrete cone resistance: NRd,c = N 0 Rd,c fb f1,n f2,n f3,n fh,n fre,n - Concrete splitting resistance (only non-cracked concrete): NRd,sp = N 0 Rd,c fb f1,sp f2,sp f3,sp fh,n fre,n Basic design tensile resistance Design steel resistance NRd,s Ms 1.5 Anchor size M8 M10 M12 M16 M20 M24 NRd,s HAS 5.8 [kn] 11,3 17,3 25,3 48,0 74,7 106,7 HIT-V 5.8 [kn] 12,0 19,3 28,0 52,7 82,0 118,0 HIT-V 8.8 [kn] 19,3 30,7 44,7 84,0 130,7 188,0 HAS (-E)-R [kn] 12,3 19,8 28,3 54,0 84,0 119,8 HIT-V-R [kn] 13,9 21,9 31,6 58,8 92,0 132,1 HAS (-E)-HCR [kn] 18,0 28,0 40,7 76,7 120,0 106,7 HIT-V-HCR [kn] 19,3 30,7 44,7 84,0 130,7 117,6 2 / 2011 273 Hilti HIT-HY 150 with HAS Setting details Anchor size M8 M10 M12 M16 M20 M24 Nominal diameter of drill bit Effective embedment and drill hole depth range a) for HIT-V Effective anchorage and drill hole depth for HAS Minimum base material thickness Diameter of clearance hole in the fixture d0 [mm] 10 12 14 18 24 28 hef,min [mm] 60 60 70 80 90 100 hef,max [mm] 160 200 240 320 400 480 hef [mm] 80 90 110 125 170 210 hmin [mm] hef + 30 mm 100 mm df [mm] 9 hef + 2 d0 12 14 18 22 26 b) Torque moment Tmax [Nm] 10 20 40 80 150 200 Minimum spacing smin [mm] 40 50 60 80 100 120 Minimum edge distance cmin [mm] 40 50 60 80 100 120 Critical spacing for splitting failure scr,sp [mm] 2 ccr,sp 1,0 hef for h / hef 2,0 Critical edge distance for splitting failure c) c cr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3: 2,26 hef for h / hef 1,3: Critical spacing for concrete cone failure scr,n [mm] 2 ccr,n Critical edge distance for concrete cone failure d) c cr,n [mm] 1,5 hef For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be reduced. a) Embedment depth range: hef,min hef hef,max b) Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing and/or edge distance. c) h: base material thickness (h hmin), hef: embedment depth d) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond resistance. The simplified formula given in this table is on the save side. 272 2 / 2011

Page 22 Fen 2012 Hilti HIT-HY 150 with HAS a) The anchor spacing shall not be smaller than the minimum anchor spacing smin. This influencing factor must be considered for every anchor spacing. Influence of embedment depth on concrete cone resistance fh,n = (hef/hef,typ) 1,5 Influence of reinforcement hef [mm] 40 50 60 70 80 90 100 fre,n = 0,5 + hef/200mm 1 0,7 a) a) a) a) a) a) 0,75 0,8 0,85 0,9 0,95 1 a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,n = 1 may be applied. Shear loading The design shear resistance is the lower value of - Steel resistance: VRd,s - Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c - Concrete edge resistance: VRd,c = V 0 Rd,c fb fß f h f4 f hef fc Basic design shear resistance Design steel resistance VRd,s Ms = Vary according to ETA Anchor size M8 M10 M12 M16 M20 M24 VRd,s HAS 5.8 [kn] 6,8 10,4 15,2 28,8 44,8 64,0 HIT-V 5.8 [kn] 7,2 12,0 16,8 31,2 48,8 70,4 HIT-V 8.8 [kn] 12,0 18,4 27,2 50,4 78,4 112,8 HAS (-E)-R [kn] 7,7 12,2 17,3 32,7 50,6 71,8 HIT-V-R [kn] 8,3 12,8 19,2 35,3 55,1 79,5 HAS (-E)-HCR [kn] 10,4 16,8 24,8 46,4 72,0 64,0 HIT-V-HCR [kn] 12,0 18,4 27,2 50,4 78,4 70,9 Design concrete pryout resistance VRd,cp = lower value a) of k NRd,p and k NRd,c k = 2 for hef 60 mm a) NRd,p: Design combined pull-out and concrete cone resistance NRd,c: Design concrete cone resistance Design concrete edge resistance VRd,c = V 0 Rd,c fb fß f h f4 f hef fc Mc = 1.5 Anchor size M8 M10 M12 M16 M20 M24 Non-cracked concrete V 0 Rd,c [kn] 5,9 8,6 11,6 18,7 27,0 36,6 2 / 2011 275 Hilti HIT-HY 150 with HAS Design combined pull-out and concrete cone resistance NRd,p = N 0 Rd,p fb,p f1,n f2,n f3,n fh,p fre,n Mp 1.5 Anchor size M8 M10 M12 M16 M20 M24 Typical embedment depth 80 90 110 125 170 210 hef =hef,typ [mm] N 0 Rd,p Temperature range I [kn] 14,7 17,3 25,3 26,9 43,2 60,3 N 0 Rd,p Temperature range II [kn] 10,1 11,8 17,3 18,0 28,0 37,7 N 0 Rd,p Temperature range III [kn] 8,7 10,2 15,0 15,0 25,4 33,9 Design concrete cone resistance NRd,c = N 0 Rd,c fb f1,n f2,n f3,n fh,n fre,n Design splitting resistance NRd,sp = N 0 Rd,c fb f1,sp f2,sp f3,sp f h,n fre,n Mc 1.5 Anchor size M8 M10 M12 M16 M20 M24 N 0 Rd,c [kn] 24,1 24,0 32,4 33,6 53,3 73,2 Influencing factors Influence of concrete strength on combined pull-out and concrete cone resistance Concrete strength designation (ENV 206) C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60 fb,p = (fck,cube/25n/mm²) 0,15 a) b) 1,00 1,03 1,06 1,09 1,11 1,13 1,14 a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length b) For design data of fck,cube = 15 and 20, please contact Hilti technical advisory service Influence of embedment depth on combined pull-out and concrete cone resistance fh,p = hef/hef,typ Influence of concrete strength on concrete cone resistance Concrete strength designation (ENV 206) C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60 fb = (fck,cube/25n/mm²) 0,5 a) b) 1 1,1 1,22 1,34 1,41 1,48 1,55 a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length b) For design data of fck,cube = 15 and 20, please contact Hilti technical advisory service Influence of edge distance a) c/ccr,n c/ccr,sp 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 f1,n = 0,7 + 0,3 c/ccr,n 1 f1,sp = 0,7 + 0,3 c/ccr,sp 1 0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1 f2,n = 0,5 (1 + c/ccr,n) 1 0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1 f2,sp = 0,5 (1 + c/ccr,sp) 1 a) The edge distance shall not be smaller than the minimum edge distance cmin. These influencing factors must be considered for every edge distance smaller than the critical edge distance. Influence of anchor spacing a) s/scr,n s/scr,sp 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 f3,n = 0,5 (1 + s/scr,n) 1 f3,sp = 0,5 (1 + s/scr,sp) 1 274 0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1 2 / 2011

Page 23 Fen 2012 Hilti HIT-HY 150 with HAS Influence of embedment depth hef/d 4 4,5 5 6 7 8 9 10 11 f hef = 0,05 (hef / d) 1,68 0,51 0,63 0,75 1,01 1,31 1,64 2,00 2,39 2,81 hef/d 12 13 14 15 16 17 18 19 20 f hef = 0,05 (hef / d) 1,68 3,25 3,72 4,21 4,73 5,27 5,84 6,42 7,04 7,67 Influence of edge distance a) c/d 4 6 8 10 15 20 30 40 fc = (d / c) 0,19 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50 a) The edge distance shall not be smaller than the minimum edge distance cmin. Combined tension and shear loading For combined tension and shear loading see section Anchor Design. 2 / 2011 277 Hilti HIT-HY 150 with HAS Influencing factors Influence of concrete strength Concrete strength designation (ENV 206) fb = (fck,cube/25n/mm²) 1/2 a) 1 1,1 C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60 1,22 1,34 1,41 1,48 1,55 a) f ck,cube = concrete compressive strength, measured on cubes with 150 mm side length b) For design data of fck,cube = 15 and 20, please contact Hilti technical advisory service Influence of angle between load applied and the direction perpendicular to the free edge Angle ß 0 10 20 30 40 50 60 70 80 90 f 1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50 Influence of base material thickness h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5 f h = {h/(1,5 c)} 1/2 1 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00 Influence of anchor spacing and edge distance a) for concrete edge resistance: f4 f4 = (c/hef) 1,5 (1 + s / [3 c]) 0,5 c/hef Single anchor Group of two anchors s/hef 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25 0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38 2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95 2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56 3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20 3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86 3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55 3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26 4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75 4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25 4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75 4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26 5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78 5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31 5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85 a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the minimum edge distance cmin. 276 2 / 2011

Page 24 Fen 2012 Hilti HIT-HY 150 with HIS-(R)N Embedment depth and base material thickness for the basic loading data. Characteristic resistance, design resistance, recommended loads. Characteristic resistance: non-cracked concrete C 20/25, anchor HIS-N Anchor size M8x90 M10x110 M12x125 M16x170 M20x205 Tensile NRk HIS-N [kn] 25,0 40,0 60,0 111,9 109,0 Shear VRk HIS-N [kn] 13,0 23,0 39,0 59,0 55,0 Tensile NRk HIS-RN (A4) [kn] 26,0 40,0 59,0 110,0 140,0 Shear VRk HIS-RN (A4) [kn] 13,0 20,0 30,0 55,0 83,0 Design resistance: non-cracked concrete C 20/25, anchor HIS-N Anchor size M8x90 M10x110 M12x125 M16x170 M20x205 Tensile NRd HIS-N [kn] 17,5 Shear VRd HIS-N [kn] 10,4 Tensile NRk HIS-RN (A4) [kn] 13,9 26,7 40,0 62,2 74,1 18,4 26,0 39,3 36,7 21,4 31,6 58,8 69,2 Shear VRk HIS-RN (A4) [kn] 8,3 12,8 19,2 35,3 41,5 Recommended loads a) : non-cracked concrete C 20/25, anchor HIS-N Anchor size M8x90 M10x110 M12x125 M16x170 M20x205 Tensile Nrec HIS-N [kn] 8,3 13,3 20,0 39,7 36,3 Shear Vrec HIS-N [kn] 4,3 7,7 13,0 19,7 18,3 Tensile NRk HIS-RN (A4) [kn] 8,7 13,3 19,7 36,7 46,7 Shear VRk HIS-RN (A4) [kn] 4,3 6,7 10,0 18,3 27,7 a) With overall global safety factor = 3. The recommended loads vary according to the safety factor requirement from national regulations. Service temperature range Hilti HIT-HY 150 injection mortar may be applied in the temperature ranges given below. An elevated base material temperature may lead to a reduction of the design bond resistance. Temperature range Base material temperature Maximum long term base material temperature Maximum short term base material temperature Temperature range I -40 C to +40 C +24 C +40 C Temperature range II -40 C to +80 C +50 C +80 C Temperature range III -40 C to +120 C +72 C +120 C Max short term base material temperature Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of diurnal cycling. Max long term base material temperature Long-term elevated base material temperatures are roughly constant over significant periods of time. 2 / 2011 279 Hilti HIT-HY 150 with HIS-(R)N Hilti HIT-HY 150 with HIS-(R)N Injection mortar system Benefits Hilti HIT-HY 150 330 ml foil pack (also available as 500 ml and 1400 ml foil pack) Static mixer - suitable for non-cracked concrete - suitable for dry and water saturated concrete - high loading capacity - rapid curing - small edge distance and anchor spacing possible - corrosion resistant - in service temperature range up to 120 C short term/72 C long term Internal threaded sleeve HIS-N HIS-RN Concrete Small edge distance and spacing Corrosion resistance European Technical Approval CE conformity Hilti anchor design software Approvals / certificates Description Authority / Laboratory No. / date of issue European technical approval a) DIBt, Berlin ETA-05/0051 / 2008-10-22 a) All data given in this section according ETA-05/0051 issue 2008-10-22. Basic loading data (for a single anchor) All data in this section applies to For details see Simplified design method - Correct setting (See setting instruction) - No edge distance and spacing influence - Steel failure - Base material thickness, as specified in the table - One anchor material, as specified in the tables - Concrete C 20/25, fck,cube = 25 N/mm² - Temperate range I (min. base material temperature -40 C, max. long term/short term base material temperature: +24 C/40 C) - Installation temperature range -5 C to +40 C 278 2 / 2011

Page 25 Fen 2012 Hilti HIT-HY 150 with HIS-(R)N Setting instruction Dry and water-saturated concrete, hammer drilling a) b) a) Note: Manual cleaning for HIS-(R)N M8 and HIS-(R)N M10 only! b) Note: Extension and piston plug needed for overhead installation! For detailed information on installation see instruction for use given with the package of the product. Note: Diamond cored hole is not suitable for Hilti HY-150, please use Hilti RE500. 2 / 2011 281 Hilti HIT-HY 150 with HIS-(R)N Materials Mechanical properties of HIS-(R)N Anchor size M8x90 M10x110 M12x125 M16x170 M20x205 Nominal tensile strength fuk Yield strength fyk Stressed crosssection As HIS-N [N/mm²] 490 490 460 460 460 Screw 8.8 [N/mm²] 800 800 800 800 800 HIS-RN [N/mm²] 700 700 700 700 700 Screw A4-70 [N/mm²] 700 700 700 700 700 HIS-N [N/mm²] 410 410 375 375 375 Screw 8.8 [N/mm²] 640 640 640 640 640 HIS-RN [N/mm²] 350 350 350 350 350 Screw A4-70 [N/mm²] 450 450 450 450 450 HIS-(R)N [mm²] 51,5 108,0 169,1 256,1 237,6 Screw [mm²] 36,6 58 84,3 157 245 resistance W Moment of Screw [mm³] 31,2 62,3 109 277 541 HIS-(R)N [mm³] 145 430 840 1595 1543 Material quality Part Material Internal threaded sleeve a) C-steel 1.0718, EN 10277-3 HIS-N Steel galvanized 5 m EN ISO 4042 Internal threaded sleeve a) HIS-RN Stainless steel 1.4401 and 1.4571 EN 10088 a) related fastening screw: strength class 8.8 EN ISO 898-1, A5 > 8% Ductile steel galvanized 5 m EN ISO 4042 b) related fastening screw: strength class 70 EN ISO 3506-1, A5 > 8% Ductile stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 EN 10088 Anchor dimensions Anchor size Internal threaded sleeve HIS-N / HIS-RN M8x90 M10x110 M12x125 M16x170 M20x205 Embedment depth hef [mm] 80 90 110 125 170 Setting installation equipment Anchor size M8x90 M10x110 M12x125 M16x170 M20x205 Rotary hammer TE 2 TE 16 TE 40 TE 70 Other tools compressed air gun or blow out pump, set of cleaning brushes, dispenser 280 2 / 2011

Page 26 Fen 2012 Hilti HIT-HY 150 with HIS-(R)N Anchor size M8x90 M10x110 M12x125 M16x170 M20x205 Nominal diameter of d0 [mm] 14 18 22 28 32 drill bit Diameter of element d [mm] 12,5 16,5 20,5 25,4 27,6 Effective anchorage and drill hole depth Minimum base material thickness Diameter of clearance hole in the fixture Thread engagement length; min - max hef [mm] 90 110 125 170 205 hmin [mm] 120 150 170 230 270 df [mm] 9 12 14 18 22 hs [mm] 8-20 10-25 12-30 16-40 20-50 Torque moment a) Tmax [Nm] 10 20 40 80 150 Minimum spacing smin [mm] 40 45 55 65 90 Minimum edge distance Critical spacing for splitting failure cmin [mm] 40 scr,sp [mm] 2 ccr,sp 45 55 65 90 1,0 hef for h / hef 2,0 Critical edge distance for splitting failure b) c cr,sp [mm] 4,6 hef - 1,8 h for 2,0 > h / hef > 1,3: 2,26 hef for h / hef 1,3: Critical spacing for concrete cone failure scr,n [mm] 2 ccr,n Critical edge distance for concrete cone failure c) ccr,n [mm] 1,5 hef For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be reduced. a) Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing and/or edge distance. b) h: base material thickness (h hmin), hef: embedment depth c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond resistance. The simplified formula given in this table is on the save side. 2 / 2011 283 Hilti HIT-HY 150 with HIS-(R)N Working time, Curing time Temperature of the base material TBM Working time tgel Curing time -5 C TBM 0 C 90 min 9 h 0 C TBM 5 C 45 min 4,5 h 5 C TBM 10 C 20 min 2 h tcure a) 10 C TBM 20 C 6 min 90 min 20 C TBM 30 C 4 min 50 min 30 C TBM 40 C 2 min 40 min a) The curing time data are valid for dry anchorage base only. For water saturated anchorage bases the curing times must be doubled. Setting details 282 2 / 2011 d 0 d f hs Bore hole depth h0 = Embedment depth hef d

Page 27 Fen 2012 Hilti HIT-HY 150 with HIS-(R)N Design concrete cone resistance NRd,c = N 0 Rd,c fb f1,n f2,n f3,n fh,n fre,n Design splitting resistance NRd,sp = N 0 Rd,c fb f1,sp f2,sp f3,sp f h,n fre,n Mc 1.5 Anchor size M8 M10 M12 M16 M20 N 0 Rd,c [kn] 28,7 38,8 47,1 62,2 82,3 Influencing factors Influence of concrete strength on combined pull-out and concrete cone resistance Concrete strength designation (ENV 206) C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60 fb,p = (fck,cube/25n/mm²) 0,15 a) 1,00 1,03 1,06 1,09 1,11 1,13 1,14 a) f ck,cube = concrete compressive strength, measured on cubes with 150 mm side length Influence of embedment depth on combined pull-out and concrete cone resistance fh,p = 1 Influence of concrete strength on concrete cone resistance Concrete strength designation (ENV 206) C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60 fb = (fck,cube/25n/mm²) 0,5 a) 1 1,1 1,22 1,34 1,41 1,48 1,55 a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length b) For design data of fck,cube = 15 and 20, please contact Hilti technical advisory service Influence of edge distance a) c/ccr,n c/ccr,sp 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 f1,n = 0,7 + 0,3 c/ccr,n 1 f1,sp = 0,7 + 0,3 c/ccr,sp 1 0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1 f2,n = 0,5 (1 + c/ccr,n) 1 0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1 f2,sp = 0,5 (1 + c/ccr,sp) 1 a) The edge distance shall not be smaller than the minimum edge distance cmin. These influencing factors must be considered for every edge distance smaller than the critical edge distance. Influence of anchor spacing a) s/scr,n s/scr,sp 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 f3,n = 0,5 (1 + s/scr,n) 1 0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1 f3,sp = 0,5 (1 + s/scr,sp) 1 a) The anchor spacing shall not be smaller than the minimum anchor spacing smin. This influencing factor must be considered for every anchor spacing. Influence of embedment depth on concrete cone resistance fh,n = 1 2 / 2011 285 Hilti HIT-HY 150 with HIS-(R)N Simplified design method Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in ETA-05/0051, issue 2008-10-22. Influence of concrete strength Influence of edge distance Influence of spacing Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two anchors or more than one edge distance. The influencing factors must then be considered for each edge distance and spacing. The calculated design loads are then on the save side: They will be lower than the exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design software PROFIS anchor) The design method is based on the following simplification: No different loads are acting on individual anchors (no eccentricity) The values are valid for one anchor. For more complex fastening applications please use the anchor design software PROFIS Anchor. Tension loading The design tensile resistance is the lower value of - Steel resistance: NRd,s - Combined pull-out and concrete cone resistance: NRd,p = N 0 Rd,p fb,p f1,n f2,n f3,n fh,p fre,n - Concrete cone resistance: NRd,c = N 0 Rd,c fb f1,n f2,n f3,n fh,n fre,n - Concrete splitting resistance (only non-cracked concrete): NRd,sp = N 0 Rd,c fb f1,sp f2,sp f3,sp fh,n fre,n Basic design tensile resistance Design steel resistance NRd,s Ms 1.43 Anchor size M8x90 M10x110 M12x125 M16x170 M20x205 NRd,s HIS-N [kn] 17,5 30,7 44,7 80,3 74,1 HIS-RN [kn] 13,9 21,9 31,6 58,8 69,2 Design combined pull-out and concrete cone resistance NRd,p = N 0 Rd,p fb,p f1,n f2,n f3,n fh,p fre,n Mp 1.5 Anchor size M8x90 M10x110 M12x125 M16x170 M20x205 Embedment depth hef [mm] 90 110 125 170 205 N 0 Rd,p Temperature range I [kn] 23,3 26,7 40,0 63,9 77,8 N 0 Rd,p Temperature range II [kn] 13,3 20,0 26,7 41,7 52,8 N 0 Rd,p Temperature range III [kn] 10,7 13,3 20,0 27,8 33,3 284 2 / 2011

Page 28 Fen 2012 Hilti HIT-HY 150 with HIS-(R)N Influence of angle between load applied and the direction perpendicular to the free edge Angle ß 0 10 20 30 40 50 60 70 80 90 f 1 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50 Influence of base material thickness h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 1,5 f h = {h/(1,5 c)} 1/2 1 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00 Influence of anchor spacing and edge distance a) for concrete edge resistance: f4 f4 = (c/hef) 1,5 (1 + s / [3 c]) 0,5 c/hef Single anchor Group of two anchors s/hef 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25 0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38 2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95 2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56 3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20 3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86 3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55 3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26 4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75 4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25 4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75 4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26 5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78 5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31 5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85 a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the minimum edge distance cmin. Influence of embedment depth Anchor size M8 M10 M12 M16 M20 f hef = 1,38 1,21 1,04 1,22 1,45 Influence of edge distance a) c/d 4 6 8 10 15 20 30 40 fc = (d / c) 0,19 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50 a) The edge distance shall not be smaller than the minimum edge distance cmin. Combined tension and shear loading For combined tension and shear loading see section Anchor Design. 2 / 2011 287 Hilti HIT-HY 150 with HIS-(R)N Influence of reinforcement hef [mm] 40 50 60 70 80 90 100 fre,n = 0,5 + hef/200mm 1 0,7 a) 0,75 a) 0,8 a) 0,85 a) 0,9 a) 0,95 a) a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,n = 1 may be applied. 1 Shear loading The design shear resistance is the lower value of - Steel resistance: VRd,s - Concrete pryout resistance: VRd,cp = k lower value of NRd,p and NRd,c - Concrete edge resistance: VRd,c = V 0 Rd,c fb fß f h f4 f hef fc Basic design shear resistance Design steel resistance VRd,s Ms = Vary according to ETA Anchor size M8x90 M10x110 M12x125 M16x170 M20x205 VRd,s HIS-N [kn] 10,4 18,4 26,0 39,3 36,7 HIS-RN [kn] 8,3 12,8 19,2 35,3 41,5 Design concrete pryout resistance VRd,cp = lower value a) of k NRd,p and k NRd,c k = 2 for hef 60 mm a) NRd,p: Design combined pull-out and concrete cone resistance NRd,c: Design concrete cone resistance Design concrete edge resistance VRd,c = V 0 Rd,c fb fß f h f4 f hef fc Mc = 1.5 Anchor size M8 M10 M12 M16 M20 Non-cracked concrete V 0 Rd,c [kn] 12,4 19,6 28,2 40,2 46,2 Influencing factors Influence of concrete strength Concrete strength designation (ENV 206) C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60 fb = (fck,cube/25n/mm²) 1/2 a) 1 1,1 1,22 1,34 1,41 1,48 1,55 a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length b) For design data of fck,cube = 15 and 20, please contact Hilti technical advisory service 286 2 / 2011

Anchor Technology Setting Operation Hilti Injection Technique HIT HY150 + HAS-E, HAS-ER, HIT-V Material : Anchor rod : HAS-E, HAS-ER, HIT-V Mortar cartridge : HIT HY150 (500ml packing) Dispenser : HIT MD2500, HIT P3500F, Reference : Hilti Fastening Technical Manual or Product Catalogue Setting Operation: 1. Drill the hole with dimension according to the installation details. 2. Clean the drilled hole thoroughly by using the tool kit (blow-pump & brushes). The hole should be free from water, or otherwise, the ultimate load will be reduced. 3. Open the cartridge cap, insert it into the holder and screw the mixer on it. 4. Put the cartridge into the dispenser. Page 29 Fen 2012

5. Throw away (must) first 3 trigger pulls. Release dispenser to stop the grout flowing. Anchor Technology Setting Operation 6. Insert the mixer head to the bottom of the hole and inject the mortar from bottom to the top of the hole. (Approx. 2/3 of the hole depth). 7. Insert the anchor rod slowly by turning it into the mortar up to the required depth. 8. Fix the workpiece after the grout is cured. Base material temperature Working time or gel time Curing time ( C) t work /t gel t cure -5 90min 6h 0 45min 3h 5 25min 1.5h 20 6min 50min 30 4min 40min 40 2min 30min Page 30 Fen 2012

Anchor Technology Setting Operation Hilti Injection Technique HIT HY150 + HIS-N, HIS-RN Material : Anchor rod : HIS-N, HIS-RN Mortar cartridge : HIT HY150 (500ml packing) Dispenser : HIT MD2500, HIT P3500F, Reference : Hilti Fastening Technical Manual or Product Catalogue Setting Operation: 1. Drill the hole with dimension according to the installation details. 2. Clean the drilled hole thoroughly by using the tool kit (blow-pump & brushes). The hole should be free from water, or otherwise, the ultimate load will be reduced. 3. Open the cartridge cap, insert it into the holder and screw the mixer on it. 4. Put the cartridge into the dispenser. Page 31 Fen 2012

5. Throw away (must) first 3 trigger pulls. Release dispenser to stop the grout flowing. Anchor Technology Setting Operation 6. Insert the mixer head to the bottom of the hole and inject the mortar from bottom to the top of the hole. (Approx. 2/3 of the hole depth). 7. Insert the anchor sleeve (HIS-N, HIS-RN) slowly by turning it into the mortar up to the required depth. 10 8. Fix the workpiece after the grout is cured. Base material temperature Working time or gel time Curing time ( C) t work /t gel t cure -5 90min 6h 0 45min 3h 5 25min 1.5h 20 6min 50min 30 4min 40min 40 2min 30min Page 32 Fen 2012