Declaration of Performance G0001CPCPR

Similar documents
Declaration of Performance G0001GPCPR

Declaration of Performance G0001LPCPR

Declaration of Performance G0001OPCPR

Declaration of Performance R4224IPCPR

Declaration of Performance

R4224KPCPR. Declaration of Performance. [CompanyGraphic]

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE Sikaplan WP HL

Declaration of Performance (DOP)

Declaration of Performance (DOP)

2. Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11(4):

European Technical Assessment. ETA-18/0041 of Member of. General part

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

European Technical Assessment. ETA-12/0281 of Member of. General part

Declaration of Performance

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. DoP No CPD GB (Version 1)

EFFISUS ECORK INSULATION

European Technical Assessment. ETA-18/0083 of Member of. General part

DECLARATION OF PERFORMANCE. Sikafloor-3240

DECLARATION OF PERFORMANCE. DoP No CPD GB (Version 1)

DECLARATION OF PERFORMANCE. Sikafloor-264 N

Declaration of performance

ETA-06/0076 of European Technical Assessment. Member of. General part. Technical Assessment Body issuing the

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

CE marking for Noise Barriers to be installed alongside Road Infrastructures. ENBF Guidelines & Recommendations. Version 1.

Tehnical Data Sheet Astro X-Series CE Pipe Wrap. UIC of product-type: XSPW CPR-JA5085 ETA-15/0619. ETAG 026-Part 1 ETAG 026-Part 2

THERMOFLOC. Peter Seppele GmbH Bahnhofstrasse 79 A 9710 Feistritz/Drau

Prysmian Guide to CPR

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

Glasswool UK February 2008

No: UK-WER _english. 1. Unique identification code of the product-type UK-WER _english

April Section 2.4. Built-up Metal Roofs

European Technical Assessment ETA-14/0354 of

Timber Roof Trusses - General Information

(English language translation, the original version is in French language) METISSE

fermacell AESTUVER Fire-protection board

Dome & Pyramid Rooflights

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

European Technical Approval ETA 13/0783

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE Sikaflex Tank N In combination with SikaPrimer-215

UL- E U C E R T I F I C A T E

Installation in ceilings

DECLARATION OF PERFORMANCE according to Annex III of the Regulation (EU) Nr. 305/2011 (Construction Products Regulation)

Declaration of Performance No. SUI/PP/13/CE2+ Product Type 9mm 12mm 15mm 18mm 21mm 24mm 27mm 30mm

Precast concrete composite wall with point connectors

ETA-07/0034 of 24/04/2017. European Technical Assessment. Member of. Designated according to Article 29 of Regulation (EU) No 305/2011.

April Section 3.3. Built-up Metal Walls

4.1 Ground Floors. Ground floors. Ground floor design. Technical Support Team

June Knauf Insulation with ECOSE Technology. The new generation of mineral wool

YOUR BEST CONNECTIONS 1 HALFEN GmbH

DECLARATION OF PERFORMANCE according to Annex III of the Regulation (EU) Nr. 305/2011 (Construction Products Regulation)

FIBRANgeo BP-ETICS. Rigid Stonewool insulation board with knit fibres. roduct Description. Advantages TECHNICAL DATA SHEET

Dome & Pyramid Rooflights

UL- E U C E R T I F I C A T E

June Knauf Insulation with ECOSE Technology. The new generation of mineral wool

European Technical Assessment. ETA-11/0135 of Member of. General part

UL- E U C E R T I F I C A T E

The ETA for ETICS Basics of the technical assessment of ETICS with rendering. Matthias Hammerla R&D Knauf Group

Thermal bridging. Acoustic performance

ETA-11/0466 of 21/02/2018. European Technical Assessment. Member of. Designated according to Article 29 of Regulation (EU) No 305/

COFORD 2018 WOOD TECHNOLOGY IRELAND. NO.

European Technical Assessment ETA-10/0067 of

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Construction Products Regulation. European clay bricks and blocks industry

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

KITS FOR EXTERNAL THERMAL INSULATION COMPOSITE SYSTEM (ETICS) WITH PANELS AS THERMAL INSULATION PRODUCT AND DISCONTINUOUS CLADDINGS AS EXTERIOR SKIN

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Product Information Sheet

Quality Regulations for Sandwich Panels

European Technical Assessment. ETA-10/0291 of Member of. General part

Legal Obligations of Distributors under the Construction Products Regulation and other Associated European Legislation as from 1 st July 2013

European Technical Assessment. ETA-15/0540 of Member of. General part

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

EAD December 2017 EXTRUDED POLYSTYRENE FOAM BOARDS AS LOAD BEARING LAYER AND / OR THERMAL INSULATION OUTSIDE THE WATERPROOFING

Declaration of Performance

CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT

DECLARATION OF PERFORMANCE

SUITABILITY: SMARTPLY OSB3 - ZERO ADDED FORMALDEHYDE

European Technical Approval ETA-13/0623

FIBRANgeo R-050. Stonewool Insulation Roll. Product Description. Advantages TECHNICAL DATA SHEET

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

European Technical Assessment ETA-17/0741 of 29/08/2017

U L - E U C E R T I F I C A T E

Built-up metal walls. Built-up metal wall design. 3.3 Built-up Metal Walls

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

European Technical Assessment. ETA-14/0349 of Member of. General part

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

DECLARATION OF PERFORMANCE

Other quality certification includes SINTEF (Norway) and SmartPly OSB is manufactured in accordance with the

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

European Technical Approval No. ETA-12/0056

FIBRANgeo BP 30. Rigid Stonewool insulation board with knit fibres. Product Description. Advantages TECHNICAL DATA SHEET

Product Information Sheet

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

Transcription:

Declaration of Performance G0001CPCPR (This document references Knauf Insulation DOP s G4207CPCPR and G4209CPCPR) 1. Unique Identification code of the product-type: Earthwool CarbonZero Roll, CarbonZero Loft Roll, Loft Roll Combi Cut, Loft Roll Ready Cut, Loft Roll Uncut, Universal Roll, Frametherm Roll, Classic 044, Frametherm 044, Loftroll Combi-cut Uncut Ready Cut, One Roll, Carbon Zero Roll. 2. Type, Batch or serial number or any other element allowing identification of the construction product as required under article 11(4) of the CPR: See Product Label. 3. Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification foreseen by the manufacturer: Thermal Insulation for Buildings (ThIB) - EN 13162:2012 4. Name, registered trade name or registered trade mark and contact address of the manufacturer as required under Article 11(5): Knauf Insulation Am Bahnhof 7, 97346 Iphofen, Deutschland www.knaufinsulation.com Contact: dop@knaufinsulation.com 5. Where applicable, name and contact address of the authorised representative whose mandate covers the tasks specified in Article 12(2): Not applicable. 6. System or systems of assessment and verification of constancy of performance of the construction product as set out in Annex V: AVCP System 1 for Reaction to Fire AVCP System 3 for the other characteristics 7. In case of the declaration of performance concerning a construction product covered by a harmonised standard: BSI (Notified certification body N 0086) performed the initial inspection of the manufacturing plant and factory production control and the continuous surveillance, assessment and evaluation of factory production control; and issued the certificate of constancy of performance for reaction to fire. BSI (Notified testing laboratory N 0086) performed the test reports for the other declared characteristics. 8. In case of the declaration of performance concerning a construction product for which a European Technical Assessment has been issued: Not applicable. G0001CPCPR - 17/11/2015 Version 2.0 1 6

9. Declared Performances: G0001CPCPR Essential Characteristics Performance Earthwool CarbonZero Roll CarbonZero Loft Roll Loft Roll Combi Cut, Ready Cut, Uncut Technical Specification Thermal conductivity (W/mK) 0,044 0,044 0,044 See product label Thickness range (mm) 50-260 50-260 50-260 Thickness tolerance T1 T1 T1 Reaction to Fire Reaction to fire A1 A1 A1 Continuous glowing combustion Continuous glowing combustion Tensile/Flexural strength Tensile strength perpendicular faces Durability of compressive Strength against ageing / Durability of reaction to fire against heat, weathering, ageing / Durability of thermal resistance against heat, weathering, ageing / Cmpressive Strength/Compressive Point Load Compressive creep Durability Characteristics ª b Thermal conductivity b Durability characteristics c Short term water absorption Long term water absorption EN13162:2012 Water vapour transmission, water vapour diffusion resistance factor Dynamic stiffness Impact noise transmissions index (for floors) Thickness L Compressibility c Air flow resistivity Acoustic absorptions index Sound absorption Direct airborne sound insulation index Air flow resistivity Release of dangerous substances to the indoor environment No performance determined Release of dangerous substances G0001CPCPR - 17/11/2015 Version 2.0 2 6

Essential Characteristics Performance G0001CPCPR Universal Roll Frametherm Roll Technical Specification Thermal conductivity (W/mK) 0.044 0.044 See product label Thickness range (mm) 50-260 50-260 Thickness tolerance T1 T1 Reaction to Fire Reaction to fire A1 A1 Continuous glowing combustion Continuous glowing combustion Tensile/Flexural strength Tensile strength perpendicular faces Durability of compressive Strength against ageing / Durability of reaction to fire against heat, weathering, ageing / Durability of thermal resistance against heat, weathering, ageing / Cmpressive Strength / Compressive Point Load Compressive creep Durability Characteristics ª b Thermal conductivity b Durability characteristics c Short term water absorption Long term water absorption EN13162:2012 Water vapour transmission / water vapour diffusion resistance factor Dynamic stiffness Impact noise transmissions index (for floors) Thickness L Compressibility c Air flow resistivity Acoustic absorptions index Sound absorption Direct airborne sound insulation index Release of dangerous substances to the indoor environment Air flow resistivity Release of dangerous substances No performance determined G0001CPCPR - 17/11/2015 Version 2.0 3 6

Essential characteristics DOP No G0001CPCPR Performance Classic 044 Frametherm 044 Loft roll (combi-cut, Uncut Ready Cut) Thermal conductivity (W/mK) 0.044 0.044 0.044 See product label See product label See product label Thickness range (mm) 50-200 90-140 100-200 Thickness tolerance T1 T1 T1 technical specification Reaction to Fire Reaction to fire A1 A1 A1 Continuous glowing combustion Tensile/Flexural strength Continuous glowing combustion Tensile strength perpendicular faces d Compressive / Compression Point Load Durability of compressive Strength against ageing / Durability of reaction to fire against heat, weathering, ageing/ Durability of thermal resistance against heat, weathering, ageing/ Compressive creep Durability Characteristics ª b Thermal conductivity b Durability characteristics c Short term water absorption Long term water absorption EN 13162:2012 Water vapor transmission, water vapour diffusion resistance factor Dynamic stiffness Impact noise transmissions index (for floors) Thickness L Compressibility c Air flow resistivity Acoustic absorptions index Sound absorption Direct airborne sound insulation index Release of dangerous substances to the indoor environment Air flow resistivity Release of dangerous substances No performance determined G0001CPCPR - 17/11/2015 Version 2.0 4 6

Essential characteristics DOP No G0001CPCPR Performance One Roll Carbon Zero Roll technical specification Thermal conductivity (W/mK) 0.044 0.044 See product label See product label Thickness range (mm) 250 170 Thickness tolerance T1 T1 Reaction to Fire Reaction to fire A1 A1 Continuous glowing combustion Tensile/Flexural strength Continuous glowing combustion NDP Tensile strength perpendicular faces d Compressive / Compression Point Load Durability of compressive Strength against ageing / Durability of reaction to fire against heat, weathering, ageing/ Durability of thermal resistance against heat, weathering, ageing/ Compressive creep Durability Characteristics ª b Thermal conductivity b Durability characteristics c Short term water absorption Long term water absorption EN 13162:2012 Water vapor transmission, water vapour diffusion resistance factor Dynamic stiffness Impact noise transmissions index (for floors) Thickness L Compressibility c Air flow resistivity Acoustic absorptions index Sound absorption Direct airborne sound insulation index Release of dangerous substances to the indoor environment Air flow resistivity Release of dangerous substances No performance determined G0001CPCPR - 17/11/2015 Version 2.0 5 6

10. The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9. This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4. Signed for and on behalf of the manufacturer by: Ian Gornall - Plant Manager (Name and function) St Helens, UK - 16/11/2015 (Place and date of issue) (Signature) Darren Holt Plant Manager (Name and function) Cwmbran 16/11/2015 (Place and date of issue) (Signature) This document is outside of the Knauf Insulation management system and therefore uncontrolled. To ensure accuracy of the required information, please refer to: www.dopki.com using the DOP code provided on the product packaging. ª No change in reaction to fire properties for MW Products The fire performance of MW does not deteriorate with time. The Euroclass classification of the product is related to the organic content, which cannot increase with time ᵇ Thermal conductivity of MW products does not change with time, experience has shown the fibre structure to be stable and the porosity contains no other gases than atmospheric air For dimensional stability thickness only This characteristic also covers handling and installation European test methods are under development ᶠ Also valid and applicable for multilayers G0001CPCPR - 17/11/2015 Version 2.0 6 6