Richmond Hill Primary Renovation SECTION COMPARTMENTS AND CUBICLES

Similar documents
Construction Standards PAGE

Missouri S&T Bullman Showers Date: February 13, 2017 Project No SECTION PLASTIC SHOWER AND DRESSING COMPARTMENTS

SECTION PLASTIC TOILET COMPARTMENTS

PLASTIC LAMINATED COMPARTMENTS SECTION TOILET PARTITIONS

AD 0 O~ Partitions, Inc East La Palma Avenue - Anaheim, California Ph: and Fax:

H D P SOLID PHENOLIC FLOOR BRACED COMPARTMENTS SECTION FB TOILET PARTITIONS

SECTION TOILET AND BATH ACCESSORIES ADDENDUM NO.4

H D P SOLID PHENOLIC CEILING HUNG COMPARTMENTS SECTION CH TOILET PARTITIONS

PLASTIC LAMINATED FLOOR TO CEILING COMPARTMENTS SECTION FC TOILET PARTITIONS

HDPE SOLID POLYMER-PLASTIC FLOOR TO CEILING COMPARTMENTS SECTION FC WEIS/POLY TOILET PARTITIONS

HDPE SOLID POLYMER-PLASTIC FLOOR BRACED COMPARTMENTS SECTION FB WEIS/POLY TOILET PARTITIONS

A This Section includes stock, manufactured toilet compartments.

SECTION TOILET PARTITIONS. A. Section Structural Steel: Supports for ceiling hung compartments.

B. LEED Submittals (Projects authorized for LEED certification only)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

10155 Toilet Compartments

Hamilton International Air Cargo Logistics Facility Section November 2014 Page 1 of 4

SECTION SOLID PHENOLIC PLASTIC TOILET PARTITIONS

e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced.

OREGON STATE UNIVERSITY GOSS STADIUM - CLUB AND LOGE SEATING CORVALIS, OREGON SECTION WALL AND DOOR PROTECTION


SECTION PREFABRICATED SHOWER COMPARTMENTS

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.

Privacy Plus Partitions

SOLID PLASTIC TOILET PARTITIONS. A. Section Includes: Toilet partitions and urinal screens, complete with hardware.

SECTION SOLID PLASTIC TOILET PARTITIONS. A. Section Includes: Toilet partitions and urinal screens, complete with hardware.

SECTION TOILET COMPARTMENTS SPEC WRITER NOTES:

PRODUCT SPECIFICATIONS - SERIES 1090

.1 Underwriters' Laboratories of Canada (ULC)..1 CAN/ULC-S102-M88(R2000), Surface Burning Characteristics of Building Materials and Assemblies.

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

SECTION SOLID COLOR REINFORCED COMPOSITE TOILET PARTITIONS

SECTION ALUMINUM HANDRAIL SYSTEMS

ROWAN/KANNAPOLIS - ABC STORE & WAREHOUSE DECEMBER 2016 Salisbury, NC

SECTION TOILET COMPARTMENTS

Project No: Pakenham Branch Library, Pakenham, Ontario Section

B. Surface, partition and recessed mounted toilet and bath accessories indicated on the Drawings and Schedules.

.2 Section Waste Management and Disposal. 1.2 REFERENCES.1 Codes and standards referenced in this section refers to the latest edition thereof.

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section Toilet, Bath and Laundry Accessories Page 1 of 6

All proposals will be evaluated by a district committee. The following criteria/weighting will be used to evaluate each proposal:

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

A2.0 TRIPLE M DEVELOPMENT EXTERIOR ELEVATIONS. Rochester, MN Hwy 52 North. Apr 07, phone fax

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS

SECTION METAL ATHLETIC LOCKERS

Bradley Bradmar Plastic Toilet Partitions

SECTION NON-STRUCTURAL METAL FRAMING

Bradley Mills Stainless Steel Toilet Partitions

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Bradley Mills Plastic Laminate Toilet Partitions

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION METAL ATHLETIC LOCKERS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION IMPACT RESISTANT WALL PROTECTION

Architectural Specifications, Section Phenolic Lockers

1. Bullet resistant hollow metal door and frame assemblies tested in accordance with UL 7 52 and in compliance with the following:

SECTION SHOWER AND DRESSING COMPARTMENTS

University Apartments on Brooklyn PROJECT MANUAL

SECTION MISCELLANEOUS METALS

Specification Floor-To-Ceiling Solid Plastic Toilet Compartments

SECTION MEDICATION CABINET. 1.1 SUMMARY A. Section Includes: 1. Medication cabinets with self-contained refrigerator and fixtures.

SECTION METAL STUDENT LOCKERS

SECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS

A. Access doors and frames are part of an access door and frame allowance.

SECTION TOILET ACCESSORIES

Shop Drawings: Show fabrication and installation details for signs.

Missouri University of Science and Technology 11/12 James E. Bertelsmeyer Hall Rolla, Missouri

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Sanymetal Partitions

Blessed Sacrament School- Phase I SECTION VISUAL DISPLAY BOARDS

1.3 SHOP DRAWINGS.1 Make all submittals in accordance with Division 1, General Requirements

SECTION METAL EQUIPMENT LOCKERS

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

SECTION METAL STAIRS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

DETAILED METAL DOOR SPECIFICATION. UNIVERSITY CONTACT: Mark Golden, Supervisor of Structural Services (302)

DIVISION 10 SPECIALTIES I I. Libbie Young Centre, Lloydminster, AB th Avenue, Regina, SK 23 March David W. Edwards Architect Ltd

1. Standard two tier metal lockers and metal base.

1. Plastic-laminate-faced toilet compartments configured as toilet enclosures and urinal screens.

Accessible Toilet and Bathing Rooms

A. All tackboards shall be mechanically fastened to walls; gluing shall not be allowed.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

WEC Manufacturing Phone: (901) Website: Itswec.com

SECTION METAL BUILDING SYSTEMS

Aluminum Perforated Rolling Door

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

Student Services & Classroom Addition

SECTION ACCESS DOORS AND FRAMES

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION ENTRANCE FLOOR GRILLES SPECIFICATIONS

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

SECTION METAL LOCKERS

DIVISION 10 SPECIALTIES DIVISION 10 - SPECIALTIES

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

SECTION ORNAMENTAL ALUMINUM FENCING

Division 11 - Equipment Section 11401

Transcription:

SECTION 10 1500 COMPARTMENTS AND CUBICLES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work of this Section. 1.02 SUMMARY A. Extent of compartments and cubicles is indicated on drawings. B. Provide one of the following types of toilet compartments: 1. Plastic laminate finish. - solid phenolic core C. Styles of toilet compartments include: 1. Floor-anchored, overhead braced. D. Toilet accessories, such as toilet paper holders, grab bars, purse shelves, specified elsewhere in Division 10. 1.03 SUBMITTALS A. Product Data: Submit manufacturer's detailed technical data for materials, fabrication, and installation, including catalog cuts of anchors, hardware, fastenings, and accessories. B. Shop Drawings: Submit shop drawings for fabrication and erection of toilet partition assemblies not fully described by product drawings, templates, and instructions for installation of anchorage devices built into other work. 1.04 QUALITY ASSURANCE A. Field Measurements: 1. Take field measurements prior to preparation of shop drawings and fabrication where possible, to ensure proper fitting of work. 2. Allow for adjustments within specified tolerances wherever taking of field measurements before fabrication might delay work. B. Coordination: Furnish inserts and anchorages to be built into other work for installation of toilet partitions and related work; coordinate delivery with other work to avoid delay. COMPARTMENTS & CUBICLES 10 1500-1

PART 2 - PRODUCTS 2.01 MANUFACTURERS A. Manufacturer: Subject to compliance with requirements, provide products of one of the following: 1. AmproProducts, Inc. 2. Columbia Partitions, Inc. 3. Comtec Inc. 4. Flush Metal Partishions. 5. Rockville Partitions, Inc. 6. Sanymetal Products Co. 7. American Sanitary Partition Corp. 8. Global Steel Products Corp. 2.02 MATERIALS A. General: Provide materials, which have been selected for surface flatness and smoothness. Exposed surfaces, which exhibit pitting, seam marks, roller marks, stains, discolorations, telegraphing of core material, or other imperfections on finished units are not acceptable. B. Plastic Laminate: NEMA Std. LD-3, min. 0.050" thick, color and pattern as indicated or, if not indicated, selected by Architect from manufacturer's standards. C. Core Material for Plastic Laminate: 1. Solid phenolic core with face laminate fused in fabrication to substrate with no glue line or seam visible. a. Doors and pilasters min. 3/4" finished thickness; divider panels min. 1/2" finished thickness. D. Pilaster Shoes: ASTM A 167, Type 302/304 stainless steel, min. 3" high, 20 gage, finished to match hardware. E. Continuous Brackets: 1. Full height extruded aluminum 6063-T5, mill finish, min. 1.685 lbs./l.f. or stainless steel or manufactures standard plastic. 2. Use for pilaster to wall connections, pilaster to partitions and partitions to walls. 3. Pre-drill wall brackets with holes 6" o.c. along full length of bracket, no hole less than 3" from end of bracket. 4. Hinges:Stainless Steel though bolt. F. Hardware and Accessories: 1. Manufacturer's standard design, heavy-duty operating hardware and accessories of stainless steel. G. Overhead Bracing: Continuous extruded aluminum, anti-grip profile, with clear anodized finish. H. Anchorages and Fasteners: 1. Manufacturer's standard exposed fasteners of stainless steel, chromium-plated steel, or brass finished to match hardware, with theft-resistant type heads and nuts. 2. For concealed anchors, use hot-dip galvanized, cadmium-plated, or other rust-resistant protectivecoated steel. COMPARTMENTS & CUBICLES 10 1500-2

2.03 FABRICATION A. General: 1. Furnish standard doors, panels, screens, and pilasters fabricated for partition system, unless otherwise indicated. 2. Furnish units with cutouts, drilled holes, and internal reinforcement to receive partition-mounted hardware, accessories, and grab bars, as indicated. B. Door Dimensions: Unless otherwise indicated, furnish 24" wide inswinging doors for ordinary toilet stalls and 32" wide (clear opening) outswinging doors at stalls equipped for use by handicapped. C. Plastic Laminate Partitions and Screens: 1. Pressure-laminate one-piece face sheets to core material with no splices or joints, and with edges straight and sealed. 2. Seal exposed core material at cutouts to protect against moisture. D. Overhead-Braced Partitions: 1. Furnish galvanized steel supports and leveling bolts at pilasters, as recommended by manufacturer to suit floor conditions. 2. Make provisions for setting and securing continuous extruded aluminum anti-grip overhead-bracing at top of each pilaster. 3. Furnish shoe at each pilaster to conceal supports and leveling mechanism. E. Hardware: Furnish hardware for each compartment in partition system, as follows: 1. Hinges: (a) Cutout inset type, adjustable to hold door open at any angle up to 90º. (b) Provide gravity type, spring-action cam type, or concealed torsion rod type, to suit manufacturer's standards. 2. Latch and Keeper: Manufacturer's standard stainless steel surface-mounted latch unit, designed for emergency access, with combination rubber-faced door strike and keeper. 3. Door Pull: Manufacturer's standard stainless steel unit for out-swing doors. PART 3 - EXECUTION 3.01 INSTALLATION A. General: 1. Comply with manufacturer's recommended procedures and installation sequence. 2. Install partitions rigid, straight, plumb, and level. 3. Thru-bolt brackets to pilasters with one-way sex bolts. 4. Attachment of brackets to adjacent wall construction: (a) Toggle bolts directly behind vertical edge of pilaster, spaced 12" o.c. along full length of bracket. (b) No. 5 plastic anchors and No. 14 x 1-1/4" cadmium plated phillips head screws at each 12" interval alternately spaced between toggle bolt connections. 5. Face attachment of pilasters to masonry partitions: Toggle bolt to masonry with sex bolts and grommets 12" o.c. B. General: 1. Comply with manufacturer's recommended procedures and installation sequence. COMPARTMENTS & CUBICLES 10 1500-3

2. Install partitions rigid, straight, plumb, and level. 3. Provide max. clearances of 1/2" between pilasters and panels, and 1" between panels and walls. 4. Secure panels to walls with min. of two stirrup brackets attached near top and bottom of panel. 5. Locate wall brackets so that holes for wall anchorages occur in masonry or tile joints. 6. Secure panels to pilasters with min. of two stirrup brackets located to align with stirrup brackets at wall. 7. Secure panels in position with manufacturer's recommended anchoring devices. C. Overhead-Braced Partitions: 1. Secure pilasters to floor, and level, plumb, and tighten installation with devices furnished. 2. Secure overhead-brace to each pilaster with min. of two fasteners. 3. Hang doors and adjust so tops of doors parallel with overhead-brace when doors in closed position. D. Floor-Supported Partitions: 1. Set pilaster units with anchorages having min. of 2" penetration into structural floor, unless otherwise recommended by partition manufacturer. 2. Level, plumb, and tighten installation with devices furnished. 3. Hang doors and adjust so tops of doors level with tops of pilasters when doors in closed position. 3.02 ADJUST AND CLEAN A. Hardware Adjustment: 1. Adjust and lubricate hardware for proper operation. 2. Set hinges on inswinging doors to hold open approx. 30º from closed position when unlatched. 3. Set hinges on outswinging doors (and entrance swing doors) to return to fully closed position. B. Clean exposed surfaces of partition systems using materials and methods recommended by manufacturer, and provide protection necessary to prevent damage during remainder of construction period. END OF SECTION 10 1500 COMPARTMENTS & CUBICLES 10 1500-4

SECTION 10 8000 TOILET, BATH AND MISCELLANEOUS ACCESSORIES PART 1 - GENERAL 1.01 SUMMARY A. Related Work Specified Elsewhere: 1. Drawings, General and Supplementary Conditions, Division-1 Specification sections, apply this Section. B. Work Included in this Section: 1. Toilet Accessories: a. Mirrors (M). b. Paper Towel Dispenser (PTD). c. Toilet Tissue Dispenser (TTD). d. Paper Towel Receptacle (PTR). e. Soap Dispenser (SD). f. Grab Bar (GB). 2. Miscellaneous Accessories: a. Mop and Broom Holder (MBH). b. Baby Changing Station ( BCS) 3. Bath and Shower Accessories: a. Soap Tray (ST) b. Towel Pin (TP) c. Robe Hook (RH) d. Shower Curtain Rod (SCR) e. Shower Curtain and Hooks (SCH) f. Folding Shower Seat (FS) 1.02 QUALITY ASSURANCE A. Inserts, Anchorages: Furnish devices to be set in concrete or masonry; coordinate delivery with other work. B. Accessory Locations: Coordinate with other work to avoid interference, assure proper operation, servicing of accessories. 1.03 SUBMITTALS A. Product Data: Manufacturer's technical data, installation instructions for each unit. B. Samples: Full-size samples of units to Architect for review of design, operation; acceptable samples returned to Contractor for use in Project. C. Shop Drawings: Setting drawings, templates, instructions, directions for installation of anchorage devices, cut-out requirements in other work. TOILET AND BATH ACCESSORIES 10 8000-1

PART 2 - PRODUCTS 2.01 ACCEPTABLE MANUFACTURERS A. Manufacturer: Subject to compliance with requirements, provide toilet accessories by one of following: 1. General Accessories: a. American Specialties, Inc. b. Bobrick Washroom Equipment, Inc. c. Bradley Corp. 2.02 MATERIALS, GENERAL A. Stainless Steel: AISI Type 302/304, No. 4 finish, 22 gage (.034") min. unless otherwise indicated. B. Brass: Leaded and unleaded, flat products, FS QQ-B-613; Rods, shapes, forgings, flat products with finished edges, FS QQ-B-626. C. Sheet Steel: Cold rolled, commercial quality ASTM A 366, 20-gage (.040") min., unless otherwise indicated; surface preparation, metal pretreatment for applied finish. D. Galvanized Steel Sheet: ASTM A 527, G60. E. Galvanized Steel Mounting Devices: ASTM A 153, hot-dip galvanized after fabrication. F. Fasteners: Screws, bolts, other devices, of same material as unit or galvanized steel where concealed. 2.03 FABRICATION A. General: 1. No names labels permitted on exposed faces. 2. On interior surface not exposed to view or on back surface, identify item by printed, waterproof label or stamped nameplate with manufacturer's name, product model number. B. Surface-Mounted Units, General: 1. Except where otherwise indicated, fabricate units with tight seams, joints, roll exposed edges. 2. Hang doors, access panels with full length stainless steel piano hinge. 3. Conceal anchorage where possible. C. Recessed Toilet Accessories, General: 1. Except where otherwise indicated, fabricate all welded units, without mitered corners. 2. Hang doors, access panels with full-length stainless steel piano hinges. 3. Fully conceal anchorage when unit closed. D. Accessories scheduled at end of section form basis of quality required.. TOILET AND BATH ACCESSORIES 10 8000-2

PART 3 - EXECUTION 3.01 INSTALLATION A. Install units using manufacturers' instructions, with fasteners appropriate to substrate, recommended by unit manufacturer. B. Install units plumb, level, firmly anchor in locations at heights indicated. C. Toilet Accessories: 1. Mirrors (M): a. Location: Over each lavatory, elsewhere indicated; not required over cabinet sinks unless specifically indicated. b. Mounting: Heights indicated, except bottom of handicap mirrors max. 40" above finish floor.34 inches to bottom for Childs restroom 2. Paper Towel Dispensers (PTD): a. Location: Over each lavatory, wash fountain, elsewhere indicated; not required at cabinet sinks unless specifically indicated. b. Mounting: Max. 40" from finish floor to towel dispensing slot. 3. Toilet Tissue Dispensers (TTD): a. Location: One each water closet. b. Mounting: 3'-0" from rear wall, 2'-0" from centerline to finish floor.17-19 inches for Child restroom 4. Paper Towel Receptacles (PTR): a. Location: Where indicated; if not indicated, directed by Architect. (1) Free Standing Receptor: One each toilet, elsewhere indicated. b. Mounting (Wall Mounted Receptor): Top 28" above finish floor unless otherwise indicated. 5. Soap Dispensers (SD): a. Location: One each lavatory, elsewhere indicated; not required above wash fountains and counter sinks unless specifically indicated. b. Mounting: (1) Wall Mounted: Center above lavatory unless otherwise indicated; max. 3'-4" above finish floor to level of soap discharge or plunger.32inches for child s restroom (2) Deck Mounted: Left rear of lavatory, extend spout over edge of bowl. (3) Lavatory Mounting: In opening in lavatory. 6. Grab Bars (GB): a. Location: (1) Handicapped water closets. b. Mounting: (1) At handicapped water closets: (a) Side wall nearest water closet, edge of 48" unit 6" from rear wall. (b) Behind water closet, edge of 36" unit 6" from nearest side wall. (2) 33" above finish floor to centerline horizontal bars. (3) 25-27 Inches for Childs restroom (4) 1½" clearance between grab bar and wall; mount to withstand min. 250 lb. vertical load after installation. TOILET AND BATH ACCESSORIES 10 8000-3

D. Miscellaneous Accessories: 1. Mop and Broom Holder (MBH): a. Location: Each janitor s space containing floor or janitor s sink. b. Mounting: 4'-0" above finish floor. 3.02 ADJUSTING AND CLEANING A. Adjust toilet accessories for proper operation, verify mechanisms function smoothly. 1. Replace damaged or defective items. B. Removing temporary labels and protective coatings, clean, polish exposed surfaces. 3.03 TOILET ACCESSORY SCHEDULE SYMBOL CATALOG NUMBERS DESCRIPTION TOILET ACCESSORIES M A&J - U700P ASI - Model #0600E Bobrick - B-2907 Series Bradley - 700-6 McKinney/Parker - 150AP Mirror: Stainless steel frame, ¼" thick acrylic, mirrorized, clear acrylic sheet with silvering applied to back surface (vacuum deposition process), abrasion-resistant surface coating on exposed face; 18" wide x 30" high unless otherwise indicated on drawings. PTD A&J ASI 0210 Bobrick B-2620 Series Bradley McKinney/Parker TTD Surface-Mounted Towel Dispensers: Stainless steel unit, hinged front, tumbler lockset; pierced refill indicator slots at sides; cap. min. either 400 C-fold or 700 multifold towels. Twin Jumbo Roll Dispenser PTR A&J - U459/VL1 ASI - 0828 Bobrick - B-279 Bradley - 357 McKinney/Parker - 632 Paper Towel Receptacle, Surface-Mounted: Stainless steel, seamless exposed walls, continuously welded bottom pan; removable heavy duty vinyl liner, secured min. 4 points by grommets, stainless steel hooks; min. 6.4 gal. cap. SD GB At H.C. water closets: A&J - UG30BX-48; UG30AX-36 ASI - 3202P-48; Grab Bars: Stainless steel, Min. 18 (.050") gage wall thickness; concealed mounting, manufacturer's standard flanges and anchorages,1½" clearance between wall and inside face of bar; Manufacturer's standard non-slip texture; heavy-duty 1½"OD. TOILET AND BATH ACCESSORIES 10 8000-4

SYMBOL CATALOG NUMBERS DESCRIPTION EHD 3201P-36 Bobrick - B-62061.99 x 48"; B-6206.99 x 36" Bradley - 8122-00248; 8122-00136 McKinney/Parker - 9605F-48CP; 9605F- 36 Excel Columbia Vortex Dyson Air Blade ASI-0199 Turbo At H.C. showers modify to meet dimensional requirements indicated. Electric Hand Dryers: Mounting: Surface Finish: Porcelain Enamel Nozzle: Fixed Controls: Solid state infrared sensor touchless. Air speed 75-100 m/s @ 60cfm Dry Cycle Time: less than 15 seconds. Electric: 208-230Y. 2300 watts. GB At H.C. water closets: A&J - UG30BX-48; UG30AX-36 ASI - 3202P-48; 3201P-36 Bobrick - B-62061.99 x 48"; B-6206.99 x 36" Bradley - 8122-00248; 8122-00136 McKinney/Parker - 9605F-48CP; 9605F- 36 Grab Bars: Stainless steel, Min. 18 (.050") gage wall thickness; concealed mounting, manufacturer's standard flanges and anchorages,1½" clearance between wall and inside face of bar; Manufacturer's standard non-slip texture; heavy-duty 1½"OD. At H.C. showers modify to meet dimensional requirements indicated. MISCELLANEOUS ACCESSORIES MBH A&J - UJ13B ASI - 8215B Bobrick - B-223 x 36" Bradley - 995-4 McKinney/Parker - 233 x 36" Brocar 100E Mop and Broom Holder: 18-gage (.050") Type 304 stainless steel "hat" channel with spring loaded rubber cam type mop/broom holders; min. 36" long, 4 holders. Baby Changing Station: Wall hung molded polyethylene case TOILET AND BATH ACCESSORIES 10 8000-5

SYMBOL CATALOG NUMBERS DESCRIPTION BCS Koala Bear-Care Horizontal Safe-T-Strap Diaper Depot and table, continuous stainless steel piano hinge, bed liner dispenser, safety straps, manufacturer s standard features, color selected by Architect. SHOWER AND BATH ACCESSORIES ST TP A&J - UX80-A ASI - 0407 Bobrick - B-4380 Bradley - 9401 McKinney/Parker - 1071 A&J - UX111B ASI - 7301B Bobrick - B-677 Bradley - 9315 McKinney/Parker - 1445 Recessed Soap Tray: Stainless steel one piece construction, recessed wall mounting; mounting clamp or lugs appropriate for wall construction. Towel Pins: Min 3" projection bright polished finish Type 304 stainless steel, rectangular pin and brackets; galvanized backplate, concealed mounting. RH SCR SCH A&J - UX110B ASI - 7340B Bobrick - B-671 Bradley - 9115 McKinney/Parker - 1444 A&J - UX2-B ASI - 1206-1209 Bobrick - B-6107 McKinney/Parker - 267 A&J - 250P ASI - 1200V Bobrick - B-204 (width required) Bradley - 9333 McKinney/Parker - 269SC Single Robe Hook: Min. 2" projection, bright polished finish Type 304 stainless steel, rectangular brackets, galvanized backplates for concealed mounting. Shower Curtain Rod, Normal Duty: 1" O.D., 20-gage (.040") stainless steel satin finish; 3" O.D. or 2½ square, min. 20-gage stainless steel flanges, satin finish, exposed fasteners. Shower Curtain, Vinyl: width required x 72" high, x 8 mil opaque matte vinyl material, hemmed edges, corrosion resistant grommets 6" o.c. through top hem; white color unless otherwise indicated; chrome plated or stainless steel spring wire curtain hooks, snap fasteners, sized for specified curtain rod. FSS A&J - U933P-R or -L ASI - 8210A Bobrick - B-5171 or B- 5181 Bradley - 956 or 9561 McKinney/Parker - 274 Folding Shower Seat: Heavy-duty hinged seat, fold up against wall when not in use; Type 304 stainless steel support braces, hinges, frame, fasteners; all welded tubular frame construction for max. strength; "L"-shaped seat, easy wheelchair access; phenolic or polymeric composite seat, either slat type or onepiece construction; color selected from manufacturers standard selections. TOILET AND BATH ACCESSORIES 10 8000-6

END OF SECTION 108000 TOILET AND BATH ACCESSORIES 10 8000-7