NAVSEA STANDARD ITEM. 2.1 S9086-RJ-STM-010/CH-504, Pressure, Temperature and Other Mechanical and Electromechanical Measuring Instruments

Similar documents
NAVSEA STANDARD ITEM. 2.1 S9086-RJ-STM-010/CH-504, Pressure, Temperature and Other Mechanical and Electromechanical Measuring Instruments

NAVSEA STANDARD ITEM. 1.1 Title: Globe, Globe Angle, and Globe Stop Check Valve; repair

NAVSEA STANDARD ITEM. 2.1 S9086-RJ-STM-010/CH-504, Pressure, Temperature and Other Mechanical and Electromechanical Measuring Instruments

NAVSEA STANDARD ITEM. 2.1 T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods

SECTION SLUICE GATES

SECTION MISCELLANEOUS METALS

Mechanical Requirements for Stainless Steel & Non-Ferrous Fasteners

Design and Construction Standards SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING

All definitions are defined according to ANSI/AWWA C

SECTION HYDRONIC PIPING

ITEM 442 METALS FOR STRUCTURES

SECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications.

FEDERAL SPECIFICATION SCREW, MACHINE, SLOTTED, CROSS-RECESSED OR HEXAGON HEAD

MILITARY STANDARD SCHEDULE OF PIPING, VALVES, FITTINGS, AND ASSOCIATED PIPING COMPONENTS FOR NAVAL SURFACE SHIPS

FF-B-575C May 26, 1970 SUPERSEDING Fed. Spec. FF-B-575B September 12, 1960 Fed. Spec. FF-B-571A (In part) January 9, 1934 FEDERAL SPECIFICATION

Material and Process. Specification

DETAIL SPECIFICATION SHEET NIPPLE, FLARELESS, TUBE TO HOSE - SWIVEL NUT

SECTION COILING COUNTER DOORS

SECTION FIRE HYDRANTS

A. Product Data: For Piping, fittings, transition fittings and dielectric fittings.

SECTION FLAGPOLES

PISTON BALANCED THROTTLING

SECTION of GENERAL. A. Description

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Division 11 - Equipment Section 11401

Diffused Aeration Piping Equipment

MIL-DTL-8348K w/ AMENDMENT 1 28 May 2009 SUPERSEDING MIL-DTL-8348K 21 July 2008 DETAIL SPECIFICATION

STANDARD PHRASEOLOGY SECTION A

DETAIL SPECIFICATION SHEET FITTING, HYDRAULIC TUBE, FLARED 37 DEGREE AND FLARELESS, STEEL; CAP, TUBE, 37 DEGREE FLARED

This specification describes the minimum requirements for piping systems for the following service: Plant air systems operating up to 125 PSIG.

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

CONTENTS. Fittings, Bends, and Intersections

Dimensions / Order Codes

VAREC 3600B/3650B SERIES PRESSURE OR VACUUM RELIEF VALVES INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

SECTION VALVES. This section includes materials, testing, and installation of manually operated valves.

SECTION HYDRONIC PIPING

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

BALL VALVES SPECIFICATION

Available End Connections & Size Range

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC PIPES AND TUBES

HOT, CHILLED, AND CONDENSING WATER PIPING SPECIALTIES (HVAC)

API 675 Evaluation. Section 1 General. 1.5 Referenced Publications. 1.1 Scope. 1.6 Unit Conversion. 1.2 Alternative Designs

GENERAL CONTENTS SECTION I - NUCLEAR ISLAND COMPONENTS

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted)

SECTION PLUMBING PIPING

1.2 REFERENCES.1 American National Standards Institute (ANSI)/American Society of Mechanical Engineers (ASME)

DETAIL SPECIFICATION GAGE ASSEMBLIES, AIR PRESSURE, DIAL INDICATING CHUCK TYPE, SELF-CONTAINED

AMERICAN DARLING MARK

CALAVERAS COUNTY WATER DISTRICT Ebbetts Pass Water System Reach 3A Pipeline Replacement Project CCWD CIP No ADDENDUM 2

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

DETAIL SPECIFICATION SHEET TEE, TUBE TO SWIVEL, SWIVEL ON BRANCH, 37 DEGREE FLARED

SPECIFICATIONS - DETAILED PROVISIONS Section Horizontal Centrifugal Water Pumps C O N T E N T S

DIVISION 15- MECHANICAL Section Fire Pumps

1.2 REFERENCES.1 American National Standards Institute (ANSI)/American Society of Mechanical Engineers (ASME).

FIGURE 1. INSERT, SCREW THREAD.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

88A-900 SERIES. Carbon Steel ASME Class 300 Flanged Full Port Ball Valve - 1/2 through 1

A. This Section includes the following general-duty valves: 1. Division 15 Section "Mechanical Identification" for valve tags and charts.

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

Cryogenic Service Valves

DETAIL SPECIFICATION SHEET CONNECTOR, ELECTRICAL CIRCULAR, COVER, PROTECTIVE, PLUG, SERIES III, METRIC

Globe Valve. Regulating. Service

King Portable Brinell Hardness Tester

COMPLETE REVISION May Process Industry Practices Piping. PIP PNSM0110 Purchasing Requirements for Valves

EQUIPMENT REPAIR REPORT

Code. 1) Code. Standard or Specification. Bolting

This specification describes the minimum requirements for piping systems for the following service:

All definitions are defined according to ANSI/AWWA C b. Flanged Joint: The flanged and bolted joint as described in ANSI/AWWA C110/A21.10.

DETAIL SPECIFICATION FITTINGS, PIPE, CAST BRONZE, SILVER-BRAZING, GENERAL SPECIFICATION FOR

1. Add new Section 02655: Chilled Water (CHW) Distribution System (added 30 September 2009)

SECTION STEAM AND CONDENSATE HEATING PIPING

ONE-STOP SHOP FOR AEROSPACE MATERIALS

SECTION NATURAL GAS DISTRIBUTION

DETAIL SPECIFICATION SHEET FITTINGS, HYDRAULIC TUBE, SLEEVE, DOUBLE ANGLE

Edward Valves Hermavalve A Zero-Emissions Valve from Edward Valves. V-Rep 95-1

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

ASTM B363-06a Standard Specification for Seamless and Welded Unalloyed

Low Temperature Carbon Steel ASME Class 600 Flanged Full Port Ball Valve - 1

Direct contact and metal-to-metal seating make the T-pattern globe stop valve ideal for most shut-off applications.

SECTION COLD-FORMED METAL TRUSSES

September 6, 2016 Page 1 of 5

Downloaded from

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window

ASTM A105/A105M-10. Standard Specification for Carbon Steel Forgings for. Piping Applications ¹

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

4 1 /2 MARK 73-5 AMERICAN FLOW CONTROL. It s What We Know. AMERICAN-DARLING FIRE HYDRANT AMERICAN-DARLING 4 1 /2 MARK 73-5 FIRE HYDRANT

Operating Instructions

t y p e V S A S E W A G E P U M P

This specification, applies at any Vale locations indicated with approval on the cover page, with the following exceptions:

SECTION TAPPING SLEEVES AND VALVES

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

STAINLESS STEEL. Useful Information

QUALITY ASSURANCE PROTOCOL (QAP)

FLANGED END BALL VALVE

Finish Specification

FIGURE 1. INSERT, SCREW THREAD.

A. General provisions and other plumbing systems are specified in other Sections of Division 22.

Transcription:

NAVSEA STANDARD ITEM ITEM NO: 009-96 DATE: 29 JUL 2011 CATEGORY: II 1. SCOPE: 1.1 Title: Ball Valve; repair 2. REFERENCES: 2.1 S9086-RJ-STM-010/CH-504, Pressure, Temperature and Other Mechanical and Electromechanical Measuring Instruments 3. REQUIREMENTS: 3.1 Matchmark valve parts. (V) "INSPECT PARTS FOR DEFECTS" 3.2 Disassemble, clean internal and external surfaces free of foreign matter (including paint), and inspect parts for defects. 3.3 Repair valve as follows: 3.3.1 Polish the seating surface of the valve ball to a 32 Root- Mean-Square finish to remove high spots, nicks, and burrs. 3.3.2 Remove existing and install new valve soft seats using those compatible with the system fluid, in accordance with manufacturer's specifications. 3.3.3 Chase and tap exposed threaded areas. 3.3.4 Dress and true gasket mating surfaces. (I)(G) VERIFY LEVEL I PARTS AND CLEANLINESS 3.4 Assemble valve installing new O-rings, packing and gaskets in accordance with the manufacturer's specifications, and new fasteners in accordance with Attachment A, or for DDG-51 class, Attachment B. 3.4.1 Lubricate each MIL-V-24509 valve with grease conforming to SAE-AMS-G-6032. 1 of 6 ITEM NO: 009-96

(I) or (V) "INSPECT ALIGNMENT" (See 4.3) 3.5 Inspect alignment of ports in the ball valve and body with the ball fully seated. Ball misalignment shall not be of a degree that will restrict flow. 3.6 Hydrostatically test valve as follows: 3.6.1 Hydrostatic test equipment shall have the following capabilities: 3.6.1.1 Manual overpressure protection release valve. 3.6.1.2 Self-actuated and resetting relief valve with a set point no greater than 100 PSIG above the test pressure or 10 percent above the test pressure, whichever is less. (V) "GAGE CHECK" 3.6.1.3 Master and backup test gages with gage range and graduation in accordance with Table 504-6-1 of 2.1. The backup gage shall be cross-checked to the master hydrostatic test gage up to the maximum test pressure just prior to start of testing. Master and backup gages shall track within 2 percent of each other. 3.6.1.4 Protection equipment shall be accessible and test gages shall be located where clearly visible and readable to pump operator and inspector. (V)(G) or (I)(G) "SEAT TIGHTNESS" (See 4.4) 3.6.2 Test for seat tightness alternately on each side of ball valve with the opposite side open for inspection. 3.6.2.1 Ball shall be seated by hand force. 3.6.2.2 Test shall be continued for a minimum of 3 minutes if there is no evidence of leakage or, in the event of visible leakage, until accurate determination of leakage can be made. 4. NOTES: 3.6.2.3 Allowable leakage for a soft-seated ball valve: None. 4.1 Test pressures of 3.6.2 will be specified in Work Item. 4.2 Repair of valve operating gear will be specified in Work Item. 4.3 The paragraph referencing this note is considered an (I) if the valve is Level I. If the valve is not Level I, the paragraph is considered a (V). 2 of 6 ITEM NO: 009-96

4.4 The paragraph referencing this note is considered an (I)(G) if the valve is Level I. If the valve is not Level I, the paragraph is considered a (V)(G). 4.5 Test medium will be specified in Work Item. 3 of 6 ITEM NO: 009-96

ATTACHMENT A VALVE BODY MATERIAL 1/ Alloy Steel Carbon Steel Nonferrous 2/ 3/ Studs and Bolts to MIL-DTL-1222 Nuts to MIL-DTL-1222 Grade B-16 Grade B-16 Phosphor Bronze - Silicon Bronze - Nickel Copper - Class A 4/ Grade 4 or 7 Grade 4 or 7 Phosphor Bronze - Silicon Bronze - Nickel Copper - Class A or Class B 5/ Socket Head Cap Screws FF-S-86 FF-S-86 1/ Alloy steel is of Composition A - 2-1/4 percent Chromium, one percent Molybdenum, Composition B - 1-1/4 percent Chromium, 1/2 percent Molybdenum, and Composition C - Carbon Molybdenum. 2/ Nonferrous Alloy except Aluminum. 3/ Studs shall be Class 2 or 3 fit on the nut end and Class 5 fit on the stud and, except that a Class 3 fit with a thread locking compound may be used where temperatures do not exceed 250 degrees Fahrenheit. The thread locking compound shall conform to ASTM D 5363. Check Class 3 fit stud ends in accordance with SAE-J2270. 4/ Fasteners of Nickel Copper Aluminum shall be the only type used on sea chest and hull valves. 5/ Nuts of Nickel Copper Alloy, conforming to QQ-N-281 Class A or B, or Nickel Copper Aluminum conforming to QQ-N-286 shall be the only type used on sea chest and hull valves. 4 of 6 ITEM NO: 009-96

3/ Studs and Bolts to MIL-DTL-1222 Nuts to MIL-DTL- 1222 ATTACHMENT B VALVE BODY MATERIAL 1/ Alloy Steel/Carbon Steel 5/ For services up to and including 650 degrees Fahrenheit; Grade 5 steel For services to 775 degrees Fahrenheit; Grade B-7 or B-16 For services to 1,000 degrees Fahrenheit; Grade B-16 For services in which JP-5 lubricating oil, or inflammable gas or liquid of any kind, regardless of pressure and temperature, which are within 3 feet of hot surfaces (above 650 degrees F) and where steel tubing is required; Grade 2, 5 or 8 steel Bolting subject to seawater corrosion (other than hull integrity bolting; for hull integrity bolting see Note 4) Connections in contact with bilge regions. Where strength requires ferrous bolting and is exposed to the weather; Class A Nickel - Copper alloy to QQ-N-281 or silicon bronze to ASTM B 98 with dimensions of MIL-DTL-1222. Where greater strength is required, use Nickel - Copper - Aluminum alloy QQ-N-286. 5/ For services up to and including 650 degrees Fahrenheit; Grade 5 steel For service to 775 degrees Fahrenheit; Grade 2H or 4 steel For services to 1,000 degrees Fahrenheit; Grade 4 steel 2/ Nonferrous 4/ 5/ Phosphor Bronze - Silicon Bronze - Nickel Copper - Class A Phosphor Bronze - Silicon Bronze - Nickel Copper - Class A or Class B 4/ 5/ 5 of 6 ITEM NO: 009-96

ATTACHMENT B (Con't) 1/ Alloy Steel/Carbon Steel For services in which JP-5, lubricating oil, or inflammable gas or liquid of any kind, regardless of pressure and temperature which are within 3 feet of hot surfaces (above 650 degrees F) and where steel tubing is required; Grade 5 or 8 steel Nuts subject to seawater corrosion. Connections in the bilge regions. Where strength requires ferrous material and is exposed to the weather; Class A or B Nickel Copper Alloy to QQ-N-281 or Silicon Bronze to ASTM B 98 with dimensions to MIL-DTL- 1222 2/ Nonferrous NOTES 1/ Alloy steel is of Composition A - 2-1/4 percent Chromium, one percent Molybdenum, Composition B - 1-1/4 percent Chromium, 1/2 percent Molybdenum, and Composition C - Carbon Molybdenum. 2/ Nonferrous Alloy except Aluminum. 3/ Studs shall be Class 2 or 3 fit on the nut end and Class 5 fit on the stud end, except that a Class 3 fit with a thread locking compound may be used where temperatures do not exceed 200 degrees Fahrenheit. The thread locking compound shall conform to ASTM D 5363. Check Class 3 fit stud ends in accordance with SAE-J2270. 4/ Fasteners of Nickel Copper Aluminum shall be the only type used on sea chest and hull valves. 5/ Where these materials would constitute part of a galvanic couple, proposals for alternate materials shall be submitted for approval. 6 of 6 ITEM NO: 009-96