Polycrete Big Block Standard Specification

Similar documents
UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

SECTION INSULATING CONCRETE FORMING (ICF)

SECTION PERMANENT FORMS Insulating Concrete Forms Rev

PART 1 GENERAL RELATED SECTIONS A. Section 03200: Concrete Reinforcement. B. Section 03300: Cast-In-Place Concrete.

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

SECTION INSULATING CONCRETE FORMING (ICF)

Issue Date: April 2003 Release: I. Product Specifications

Sept 30, 2004 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

SECTION INSULATED CONCRETE FORMS - RASTRA 1.01 SUMMARY

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

(800) (562) A Subsidiary of the International Code Council

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

Architectural precast Concrete EARTH FRIENDLY BLOCK

High Performance Insulating Concrete Form

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

TECHNICAL EVALUATION REPORT No. 27/2008/2060

SECTION PERMANENT FORMS - INSULATING CONCRETE FORMS Page 1 of 7

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

Sept 30, 2004 Page 1

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

ProGUARD Guide Specification

PART 1 GENERAL 1.1 SECTION INCLUDES. A. Below grade waterproofing and dampproofing 1.2 RELATED SECTIONS 1.3 REFERENCES

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION CEMENTITIOUS WOOD FIBER DECKS

SECTION NON--STRUCTURAL METAL FRAMING

ENVIROBEAM SECTION ENVIRO-ROOF CURBS

SECTION TILT-UP PRECAST CONCRETE. A. Work includes, but is not limited to, the following:

Technical Data Sheet

SECTION ACCORDION FOLDING PARTITIONS

Insulated Concrete Forms (ICFs)

Table of Contents. 1 Introduction. 2 Description. 3 Tools and materials. 4 Footings or slabs. 5 Coursing placement. 6 Reinforcing steel

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION STRUCTURAL INSULATED PANELS

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

1. Cast-in-place concrete is specified in Section

SECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.

Section 1 - Introduction 1.1 Introduction Welcome to Fox Blocks. You have made an excellent decision to use Fox Blocks Insulated Concrete Forms (ICFs)

REINFORCED CONCRETE MASONRY SECTION

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

SPECIFICATION GUIDELINE

PS 3000 Installation Manual Step-By-Step Procedures C.9. DOOR AND WINDOW OPENINGS C.9.1 PREPARE IN ADVANCE. C.9.2 VBUCK CONSTRUCTION.

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

ICC-ES Evaluation Report Reissued September 1, 2010 This report is subject to renewal in two years.

SECTION CONCRETE FORMWORK AND ACCESSORIES

DIVISION 03 CONCRETE SPECIFICATION : FORMS AND FORMWORK

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: SUPERFORM PRODUCTS LTD. EVALUATION SUBJECT:

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION EXPANSION CONTROL

SECTION COMPOSITE METAL DECKING

DS131 EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

WEIGHT PER PIECE (LBS.)

SPECIFICATION GUIDELINE

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: AMVIC INCORPORATED

SECTION ALUMINUM STORM WINDOWS

Master Specification WALLTITE ECO v.2 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

MANUFACTURER S SPECIFICATIONS Section LIME CONCRETE. A. This section describes the requirements for floors and slabs on grade.

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

TECHNICAL SPECIFICATION

Octaform Quick Liner Wall & Ceiling Panels Guide Specification CAN Page 1

SECTION RIGID PAVEMENT

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

SECTION EXPANSION CONTROL

Expansion Joint Covers (079513)

SECTION (09265) - GYPSUM BOARD SHAFT WALL ASSEMBLIES

SECTION EXPANSION CONTROL

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

Expansion Joint Covers

Phenolic Exterior Wall Cladding

Master Specification WALLTITE Eco v.3 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

A-ONE Insulated Forms Installation Manual

SECTION COLD-FORMED METAL TRUSSES

SECTION CONCRETE FORMWORK

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

SECTION WALL AND DOOR PROTECTION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

GA APPLICATION OF GYPSUM SHEATHING

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION / STC 52 METAL SOUND CONTROL DOORS

SECTION COLD-FORMED METAL FRAMING

Gold Bond BRAND Gypsum Sheathing

SECTION Fiber Reinforced Stucco 1

ThermaSteel Corporation ASSEMBLY MANUAL

SECTION CONCRETE CURBS, GUTTERS AND SIDEWALKS

SECTION NON-STRUCTURAL METAL FRAMING

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

GUIDE SPECIFICATIONS For STRUCTURAL PRECAST HOLLOW CORE SLABS SECTION 03410

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

DOOR AND WINDOW OPENINGS PREPARE IN ADVANCE VBUCK CONSTRUCTION

SECTION EXPANSION CONTROL

TYPICAL ENGINEERED COMMERCIAL / RESIDENTIAL DETAILS & TABLES

SECTION THERMAL INSULATION

Transcription:

Polycrete Big Block Standard Specification SECTION 03 11 19 INSULATED CONCRETE FORMING 10/13 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. ACI INTERNATIONAL (ACI) ACI 117 ACI 301 ACI 318 ACI 347 (2010) Specifications for Tolerances for Concrete Construction and Materials and Commentary (2005; Errata 2008) Specifications for Structural Concrete (2008; Errata 2010) Building Code Requirements for Structural Concrete and Commentary (2004; Errata 2008) Guide to Formwork for Concrete ASTM INTERNATIONAL (ASTM) ASTM C 1363 ASTM C1622/C1622M ASTM C 177 ASTM C 203 ASTM C 578 ASTM D 1621 (2005) Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus (2010) Standard Specification for Cold- Weather Admixture Systems (2010) Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus (2005a) Breaking Load and Flexural Properties of Block-Type Thermal Insulation (2010) Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation (2010) Standard Test Method for Compressive Properties of Rigid Cellular Plastics Section 03 11 19 Page 1

ASTM D1761 ASTM E 119 ASTM E2634 ASTM E 84 ASTM E 90 (2006) Standard Test Methods for Mechanical Fasteners in Wood (2010b) Standard Test Methods for Fire Tests of Building Construction and Materials (2010) Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems (2010b) Standard Test Method for Surface Burning Characteristics of Building Materials (2009) Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements 1.2 SUBMITTALS 1. Product Data Manufacturer s product data on ICF Wall System 2. Samples Sample of product to be used 3. Test Reports Third party Test reports evidencing building code compliance 4. Certificates Manufacturer s certification of compliance with ASTM E2634 Manufacturer s certification of lateral strength Installer s successful training certification Manufacturer s product warranty 5. Manufacturer's Instructions Installation manual 1.3 QUALITY ASSURANCE 1.3.1 ICF Manufacturer Polycrete International, Inc 580 boul. Lionel-Boulet, Varennes, Québec Canada J3X 1P7 (450)985-2777 Polycrete@Polycrete.com PolycreteUSA, LLC (US Agent) 6802 Paragon Place, Suite 410, Richmond, Virginia 23230 Phone (800)570-4313 Info@PolycreteUSA.com 1.3.2 Installer Qualification Installer shall be trained by PolycreteUSA or a qualified ICF Technical Advisor to ensure product is installed in accordance with the Polycrete's published installation instructions. Installer must have experience in ICF systems and successfully completed at least three (3) projects that are similar to this project in size, scope and complexity. Section 03 11 19 Page 2

1.3.3 Pre-Installation Meetings Prior to commencement of ICF installation and associated work, conduct a meeting at project site with the ICF manufacturer's representative, and trades responsible for installing forms, concrete, and reinforcement. 1.4 DELIVERY, STORAGE, AND HANDLING Polycrete Big Block ICF is packed in bundles of 16 blocks each. Each bundle measures approximately 105 x 49 x 47 (L x W x H) and weighs 520 lbs (236 kg). Polycrete Big Block bundles must be shipped on flatbed trailer. Handle and store products in location to prevent damage, soiling, and retain original factory packaging to protect from UV light. A fork truck is required to offload product from delivery vehicle. 1.5 FIELD/SITE CONDITIONS Conform to ACI 318 for cold and hot weather concreting requirements. PART 2 PRODUCTS 2.1 SYSTEM DESCRIPTION Insulated concrete wall form system consists of two panels of molded expanded polystyrene (EPS) insulation connected by metal cross ties to act as permanent formwork for cast-in-place reinforced concrete beams, lintels, nonload-bearing walls, load-bearing walls, foundation walls, and retaining walls while provide insulating characteristics and attachment point for interior and exterior finishes. 2.1.1 Design Requirements Design, engineer, and construct formwork in accordance with methodology of ACI 347 for anticipated loads, lateral pressures, and stresses, and capable of withstanding a minimum of 1,600 lbs per square foot of lateral pressure resulting from placement and vibration of concrete. 2.1.2 Performance Requirements The Insulated Concrete Form (ICF) wall system shall provide minimum 5-5/8 and maximum 24 forming cavity width. The cavity width shall be a consistent flat rectangular cross section. Provide cross ties in the ICF wall system 8.375 o/c maximum. Steel wire cross ties shall have.16 in (4 mm) minimum thickness. Fastening strip is 22 gauge steel 1-1/8 width for the full length of the wall to fasten exterior and interior wall finishes. Wall system shall provide accurate positioning of concrete reinforcing bars within the form cavity conforming to ACI 318. Section 03 11 19 Page 3

2.2 MANUFACTURED UNITS 2.2.1 Description The ICF system includes an expanded polystyrene forming unit used to construct a monolithic reinforced concrete wall. The forms remain in place, providing a concrete wall to be finished with conventional interior and exterior wall coverings. Unit types are as follows. 1. Insulated concrete wall form system consists of a. Two (2) flame resistant panels of Expanded Polystyrene (EPS type II) b. One (1) steel wire mesh molded inside each EPS panel. c. Two (2) continuous horizontal metal fastening strips welded to the wire mesh and molded inside EPS panels at minimum 12 o/c. d. Forty-Eight (48) foldable steel ties for the 2 height EPS panels assembly spaced at maximum 8.375 o/c 2. EPS panel standard thickness is 2 ½ and 1 ¾ is available as required by design 3. Panels are provided with heights of 12 ; 18 and 24 4. Pre-assembled forms have four (4) standard dimensions to provide concrete walls with 5⅝ ; 7 ⅝ ; 9 ⅝ or 11 ⅝ thickness. a. Custom sizes up to 24 to be provided upon request 5. 90º and 135º metal corner supports (8 X 8 X 10 ) 6. Metal starting bases in 8 sections 2.2.2 Performance/Design Criteria Insulated Concrete Forms provide a minimum 5-5/8 and maximum 24 concrete "flat" cross section. Preformed forms have interlocking edges to facilitate course-to-course bonding to prevent uplift and lateral failure. a. ICF unit shall provide a minimum R-value of R-20 (2-1/2 panel) or R-14 (1-3/4 panel) b. EPS shall provide a maximum vapor permeation of 0.09 perm-meter( 3.5 perm-inch). c. Finish wall assembly shall have a minimum rating of Sound Transmission Class (STC) 50 sound attenuation performance as tested in accordance with Test Method ASTM E 90. d. The fire resistive-rated construction of the complete ICF wall assembly including EPS, cross tie material, and concrete shall be in accordance with Test Methods ASTM E 119 and be rated at a minimum of four (4) hours. Section 03 11 19 Page 4

Insulating Concrete Forming System conforms to the following requirements: TABLE 1 PROPERTIES Properties ASTM Test Value Density ASTM C1622/C1622M 21.6 kg/m3 1.40 lbs/ft3 Thermal Resistance ASTM C 177 0.275 m2.c/w per cm (min) 4.0 F.ft2.h/Btu per in (min) Ultimate withdrawal load 310 lbs Fastener Withdrawal ASTM D 1761 Allowable withdrawal load 62 lbs (#8 x 3 construction screw) Fastener Lateral Shear Compressive Strength ASTM D 1761 ASTM D 1621 Ultimate lateral shear load 375 lbs Allowable lateral shear load 90 lbs (#8 x 3 construction screw) 103 kpa 17.50 psi Flexural Strength ASTM C 203 276 kpa (min.) 41.0 psi (min) Flame Spread ASTM E 84 25 maximum Smoke Developed ASTM E 84 450 maximum 2.3 MATERIALS Submit certifications signed by ICF Manufacturer stating that product supplied meets the requirements of ASTM E2634 and that its minimum lateral strength resistance is 1,600 lbs/sqft (75 kpa). 2.3.1 Expanded Polystyrene (EPS) Expanded Polystyrene shall conform to ASTM C 578. Provide Type II EPS panels, Flame Resistant with 1-3/4 or 2-1/2 thick EPS panels as required by design. 2.3.2 Cross Ties and Fastening Strips Metal cross ties spaced at 8.375 o/c maximum. Cross ties allow for multiple reinforcement placement positions to meet the structural design. Provide metal fastening strips with 1-1/8 minimum width for the full length of the wall to fasten exterior and interior wall finishes. Fastening strips are recessed 1/4 to 1-1/2 below the outside surface of the panels. Position of fastening strips are clearly marked on the surface of the EPS panels. Section 03 11 19 Page 5

2.4 ACCESSORIES 2.4.1 Bracing, Scaffolding, and Wall Alignment Support ICF system in accordance with manufacturer s instructions prior to the attachment of permanent structural elements and before placement of concrete. 2.4.2 Door and Window Bucks Use extruded vinyl, ground rated pressure treated lumber, or metal buck material to frame door and window openings. 2.4.3 Waterproofing Waterproofing material shall be compatible with EPS system and as specified in Section [07 13 53 ELASTOMERIC SHEET WATERPROOFING] [07 14 00 FLUID-APPLIED WATERPROOFING] 2.4.4 Fasteners Fasteners of interior and exterior wall finishes to ICF wall system shall conform to ASTM D1761. Fasteners shall be corrosion-resistant and have sufficient length to penetrate the fastening strips. PART 3 EXECUTION 3.1 EXAMINATION Verify that footings and slabs are installed level and true to the structural design. Ensure dimensions and steel reinforcement are as indicated. 3.2 PREPARATION Clean top of footings and slabs of all foreign substances, frost, ice, and standing or running water prior to starting installation of ICF system. Use methods and materials approved by ICF manufacturer. 3.3 INSTALLATION Install ICF system in accordance with the manufacturer's installation and technical manual; submit a copy of the manual. Provide bracing and shoring to ensure stability of formwork to prevent overstressing of ICF units due to construction loads in accordance with ACI 301. Install ICF system in running bond pattern. Affix Starter Base to the footing before setting first course of formwork. Anchor formwork to supporting surfaces to prevent upward or lateral movement of the ICF units during concrete placement. Place sleeves, inserts, anchors, and embedded items required for adjoining work or for support of adjoining work before concrete placement. Align fastening strips to facilitate interior and exterior wall finishes. Install concrete reinforcement according to the structural drawings at all walls, lintels, beams, and around openings. Install window and door bucks at each location where an opening is required. Section 03 11 19 Page 6

Install alignment bracing around the entire wall of the structure to ensure the ICF system is straight and plumb before and during concrete placement. 3.4 CONCRETE PLACEMENT Before placing concrete, verify that installation of formwork, reinforcement, and embedded items is complete and that required inspections have been performed. Deposit concrete in horizontal layers of depth to not exceed formwork design pressures. If concrete cannot be placed in continuous pour, provide construction joints as indicated. Consolidate placed concrete with mechanical vibrating equipment conforming to ACI 301. Variations from plumb and designated building lines shall not exceed the tolerances specified in ACI 117. 3.5 FIELD QUALITY CONTROL The ICF manufacturer's representative or technical advisor shall inspect ICF installation to ensure compliance with ICF manufacturer's installation and technical manual. Inspect erected formwork, reinforcement placement, door and window opening construction, concrete placement, and alignment and bracing system to ensure that work is in accordance with drawings. Ensure that the cast-in-place concrete walls are level, plumb, square, and straight and that all dimensions conform to the drawings and are within required tolerances. 3.6 CLEANING Clean formed cavities, within ICF units, of debris and foreign matter prior to concrete placement. Clean up and properly dispose of all debris remaining on job site related to the installation of the ICF system, recycling materials as required. 3.7 PROTECTION Provide temporary coverage of installation of ICF system to reduce exposure to ultraviolet light should final finish application be delayed longer than 60 days. Section 03 11 19 Page 7