Image Quality from High-Resolution CT of the Lung: Comparison of Axial Scans and of Sections Reconstructed from Volumetric Data Acquired Using MDCT

Size: px
Start display at page:

Download "Image Quality from High-Resolution CT of the Lung: Comparison of Axial Scans and of Sections Reconstructed from Volumetric Data Acquired Using MDCT"

Transcription

1 Studler et al. High- Resolution CT and MDCT of the Lung Chest Imaging Original Research Ueli Studler 1 Thomas Gluecker Georg Bongartz Jakob Roth Wolfgang Steinbrich Studler U, Gluecker T, Bongartz G, Roth J, Steinbrich W Received June 27, 4; accepted after revision October 22, 4. 1 All authors: Department of Radiology, University Hospital Basel, Petersgraben 4, Basel, Switzerland. Address correspondence to U. Studler (studleru@tiscali.ch). AJR 5; 185: X/5/ American Roentgen Ray Society Image Quality from High-Resolution CT of the Lung: Comparison of Axial Scans and of Sections Reconstructed from Volumetric Data Acquired Using MDCT OBJECTIVE. Our objective was to compare the image quality of reconstructed thin sections obtained from a 16-MDCT scanner with that of axial high-resolution CT scans of the same patient. SUBJECTS AND METHODS. Fifty consecutive patients referred for CT of the chest underwent 16-MDCT and, subsequently, axial high-resolution CT. The volumetric raw data from the MDCT scans were reconstructed into slices 2-mm thick using a high-spatial-frequency reconstruction algorithm. Two blinded reviewers independently rated the images from both methods for subjective image-quality criteria. The results were tested for statistical significance using Wilcoxon s signed rank test, and p values of less than.5 were considered significant. The effective dose for axial high-resolution CT and volumetric MDCT was calculated. RESULTS. Motion artifacts were significantly more common on high-resolution CT scans than on reconstructed thin-section images (p <.1). The two methods differed significantly in lung attenuation (p =.8), mainly because of the presence of ground-glass opacities. The assessment of ground-glass attenuation was superior on axial high-resolution CT. The effective doses were 3.8 msv for MDCT and.9 msv for high-resolution CT. CONCLUSION. Reconstructed high-resolution images generated from a single MDCT data acquisition are of comparable quality to images obtained using conventional axial highresolution CT. However, contiguous MDCT is not recommended for diseases showing predominantly ground-glass patterns, because axial high-resolution CT delineates ground-glass attenuation significantly better. hin-section CT has become a T proven imaging technique for evaluation of patients with diffuse infiltrative lung disease [1, 2]. High-resolution CT depicts both fine normal lung parenchyma and morphologic alterations produced by various diseases [3, 4]. The technical landmarks of high-resolution CT that are applied to improve resolution are thin collimation and image reconstruction with a high-spatial-frequency algorithm [5]. High-resolution CT usually is performed in a noncontiguous manner, with images obtained at 1- to 2-cm intervals. However, many focal or diffuse chest diseases require examination of the entire thorax, without gaps. For example, in both sarcoidosis and lung cancer, mediastinal lymph nodes and the lymphatic system of the lung may be affected. In other diseases, such as silicosis, random nodules may be missed on high-resolution CT because of the limited volume of lung that is imaged. Thus, acquisition of thin-section images and simultaneous coverage of the entire chest using thick-section CT would be desirable [6]. The advantage of the newly introduced 4 (or more)-mdct over single-detector CT consists in a high-volume coverage speed without a loss of diagnostic image quality. This advantage has been shown for different section thicknesses, including high-resolution CT [7, 8]. A reduction of threefold or even more in scanning time of the chest means, for the patient, a bearable breath-hold duration and, for the radiologist, fewer breathing artifacts. Furthermore, the same raw data set obtained from MDCT using thin sections can be reconstructed to both volumetric thick-section images and thin-section highly resolved images using a high-spatialfrequency reconstruction algorithm. This technical advantage of MDCT may allow delivery of all required information about the chest in a single CT scan, with the further benefit of sparing the patient the radiation dose of an additional high-resolution CT 62 AJR:185, September 5

2 High-Resolution CT and MDCT of the Lung examination. The purpose of this study was to assess whether quality differed significantly between images obtained using reconstructed volumetric data and images obtained using axial high-resolution CT. Subjects and Methods Patients Fifty consecutive patients referred for chest CT because of known or suspected lung disease were prospectively included (23 men and 27 women; age range, years; mean, 56 years). Chest CT was part of a comprehensive clinical evaluation, and the decision to perform additional high-resolution CT was based solely on the specific clinical question. Exposure of the patient to radiation from the additional high-resolution CT examination was not considered to require approval from our institutional review board because all CT examinations were performed using the standard protocols established by our department and no CT examination was performed for study purposes only. Informed consent to review the data was obtained from the patients. The patients underwent chest CT for the following known or suspected abnormalities: idiopathic pulmonary fibrosis (n = 4), sarcoidosis (n =5), bronchiolitis obliterans (n = 4), lymphangitic carcinomatosis (n = 5), tuberculosis (n = 3), lung involvement in collagen vascular disease (n =3), various pulmonary complications after stem cell transplantation (n = 9), bronchiectasis (n =6), emphysema (n = 8), chronic eosinophilic pneumonia A Fig year-old man with severe emphysema. Images are displayed at window level of -5 H and width of 1,4 H. A, Image obtained with axial high-resolution CT (1 mm) reveals relevant motion artifacts such as doubling of left major fissure (arrow) and double images of pulmonary vessels and bronchi (arrowheads). B, Reconstructed (2-mm) high-resolution image from volumetric MDCT at corresponding level shows no motion artifacts. Detailed evaluation of image for presence of bronchiectasis and bronchial wall thickening (arrowheads), septal lines (plain arrow), and vessels (tailed arrow) is possible. Extension of emphysema is seen (asterisks). (n = 1), idiopathic pulmonary hemorrhage (n =1), and cryptogenic organizing pneumonia (n =1). None of the patients with known interstitial lung disease had been evaluated by simultaneous highresolution CT and MDCT solely for the purpose of assessing disease activity or of monitoring treatment. All patients presented with unexplained symptoms such as acute dyspnea (n = 15), fever (n = 5), and weight loss (n = 3); thus, when the underlying interstitial lung disease had been taken into account, the specific question that led to the use of both high-resolution CT and MDCT in these patients was whether pulmonary embolism, pneumonia, or lung cancer was present. MDCT Protocols All scans were obtained using 16-MDCT (Somatom Sensation, Siemens Medical Systems) with the patient supine. First, MDCT covering the whole lung was performed in a caudal-to-cranial direction during one breath-hold, resulting in a volumetric data set. Second, the same patient underwent noncontiguous axial high-resolution MDCT at 1-cm intervals. The settings used to obtain the volumetric data were 12 kv, mas (CARE Dose, Siemens), a section collimation of mm, a table feed of 3 mm per rotation, and a rotation time of.5 sec per 36 tube rotation, resulting in a beam pitch of 1.25 according to the definition of Silverman et al. [9]. From the raw data, thick contiguous sections of 3-mm collimation were reconstructed using a soft-tissue kernel and a lung kernel for routine diagnostic practice. In addition, a series of noncontiguous images consisting of the thinnest possible collimation, 2 mm, was reconstructed at 1-mm intervals using a high-spatial-frequency reconstruction algorithm (B 8s) for this study. For axial high-resolution CT, a collimation of 2 1 mm was used. A collimation of 1 1 mm was not possible because of the geometric configuration of the detector array on this scanner. The other settings for axial high-resolution CT were 12 kv, 12 mas, and a rotation time of.75 sec. Images were reconstructed with a high-spatial-frequency algorithm (B 8f). Axial high-resolution CT was not performed during a single breath-hold for each image. Instead, depending on the patient s ability to hold the breath, we scanned during two or three breathholds, between which the patient was allowed to breathe. The scanning time for both methods was recorded by the scanner. Image Analysis All images were transferred to a Magic View 1 workstation (Siemens) for Windows (Microsoft) and were displayed on the monitor for interpretation. The scans were displayed at lung window settings (level, 5 H; width, 1,4 H) and at soft-tissue window settings (level, 4 H; width, 35 H) for evaluation of the pleura. Images were analyzed independently by two experienced, boardcertified radiologists. The two reviewers were unaware of the clinical information, patient data, and acquisition technique. To avoid recall biasing, the B AJR:185, September 5 63

3 Studler et al. Reviewer 1: Distribution of HRCT s Reviewer 1: Distribution of MDCT s 4 Reviewer 2: Distribution of HRCT s 4 Fig. 2 Histograms show distribution of scores for 1 categories by reviewer and method. HRCT = high-resolution CT. 4 interpretation sessions for high-resolution CT and MDCT images were separated by at least 4 weeks. The reviewers were asked to evaluate the image quality of the normal lung structures subjectively by using the following scale: 1, excellent image quality with sharp demarcation of the structures; 2, slight blurring of the structures, with unrestricted image evaluation possible; 3, moderate blurring of the interface structures, with slightly restricted assessment; 4, severe blurring and poorly defined structures, with uncertainty about the evaluation; and 5, severely reduced image quality making reliable interpretation impossible. The assessment of normal lung structures was divided into four categories: interlobular septa; pleural and subpleural regions; centrilobular region, consisting of the centrilobular artery; and large bronchi and vessels. In a next step, the reviewers looked for the following abnormal conditions: reticular patterns, small nodules, areas of decreased lung attenuation (bulla, emphysema, or cysts), areas of increased lung attenuation (ground-glass attenuation, consolidation, or mosaic perfusion), and bronchiectasis. Both anatomic and pathologic conditions were rated by a scale ranging from 1 (best) to 5 (worst). In addition, a score of was used for absence of abnormal findings. Subsequently, the images were evaluated for evidence of artifacts, including streak artifacts and respiratory or cardiac motion artifacts (i.e., doubling of fissures, vessels, or bronchi and blurring of the contour of the heart, mediastinum, or diaphragm). The motion artifacts were not graded using a scale. Instead, the reviewers were told to record the number of nondiagnostic images (Fig. 1). Finally, the two reviewers were asked to assess the overall image quality of the entire study using the same 5-point scale. In summary, using 11 categories for each scan, both reviewers had to rate the image quality of 5 scans obtained by each method. Radiation Dose To compare the radiation exposure, the effective doses for the volumetric and axial techniques were calculated using commercially available software (WinDose, Scanditronix-Wellhoefer) that was derived from Monte Carlo calculations [1]. Statistical Analysis Statistical analyses were performed using SPSS software (release 1.1.3, SPSS, Inc.). The image quality scores from corresponding categories were summed for each reviewer, resulting in a total score for each CT technique. Wilcoxon s signed rank test was used to test pairwise for significant differences between these total scores, and p values of less than.5 were considered to indicate a statistically significant difference. Weighted kappa was used to assess the rating agreement between the two reviewers for corresponding categories of each method. Results CT Protocols and Radiation Doses The mean scanning time for volumetric MDCT was 6 sec, depending on the scan length. The net mean scanning time for axial Reviewer 2: Distribution of MDCT s 4 high-resolution CT was 24 sec. As already mentioned, this scanning time was composed of two or three packages, during which the patients had to hold their breath for 12 or 8 sec, respectively. The average breath-hold time for all axial high-resolution CT scans was 9.7 sec. The mean effective dose was 3.8 msv (3.6 msv for men and 3.9 msv for women) for volumetric MDCT and.9 msv (for both men and women) for the axial method. Image and Statistical Analyses The histograms in Figure 2 show the distribution of scores for each reviewer and method for 1 categories. The category artifact was ignored because this data type was not ordinal and could take on a continuous range of values. The shape of the histograms shows a skewed distribution of scores. Pairwise comparison of scores for normal lung structures showed no significant difference between the two methods. A good image quality for these four categories was expressed by a median score of 2. for both axial high-resolution CT and volumetric MDCT. The scores for the category increased lung attenuation were significantly higher for reconstructed images from volumetric MDCT than for the corresponding axial high-resolution CT scans (p =.82). This difference in image quality was mainly due to blurring from ground-glass attenuation on the reconstructed images of some patients 64 AJR:185, September 5

4 High-Resolution CT and MDCT of the Lung (Fig. 3). Among the other assessed alterations of lung parenchyma, including reticular changes, small nodules, increased lung attenuation, and bronchiectasis, no significant differences were found (Fig. 4). Overall image quality was rated slightly better for volumetric MDCT than for axial high-resolution CT. However, this difference was not statistically significant. The comparison of the number of motion artifacts achieved statistical significance (p=.4). Both reviewers noted more artifacts on images acquired using axial high-resolution CT (Fig. 1). The average interobserver agreement was.6 ±.16 (range,.39.82) for axial highresolution CT and.59 ±.15 (range,.36.8) for the volumetric method. Discussion Without a doubt, MDCT represents a true revolution in the assessment of chest diseases. The simultaneous acquisition of multiple slices and the use of a higher tube-rotation speed allow acquisition times to be reduced by twofold or more without compromising image quality [8]. One important benefit of the faster scanning time is the ability to examine uncooperative patients or critically sick patients who cannot reliably suspend breathing. Furthermore, with thin sections at a low pitch, near-isotropic resolution can be obtained, allowing multiplanar reconstructions [11]. Although this advancement has had substantial implications for vascular thoracic imaging [12], fewer studies have evaluated the potential advantage of A MDCT for normal and altered lung parenchyma [6, 13]. We performed the examinations with a CT unit from the latest generation of MDCT scanners, consisting of 16 detectors with an adaptive array configuration. The use of a 1.5-mm collimation in combination with a pitch of 1.25 resulted in a mean scanning time of 6 sec for the entire thorax, a duration for which most patients even those severely dyspneic could hold the breath. This contribution to the patient s comfort is reflected in a statistically significant reduction of motion artifacts on images obtained using MDCT, compared with images obtained using axial high-resolution CT (Fig. 1). We did not classify the artifacts by their various origins; instead, we considered the number of artifacts reducing image quality. This approach seems reasonable because prevention of cardiac motion artifacts using ECG-triggered thin-section CT has been shown not to improve diagnostic accuracy [14, 15]. Hence, the diagnostic relevance of heart movement artifacts might be questioned. Our findings contrast with the previous observations of Kelly and colleagues [13] that volumetric MDCT causes more motion artifacts than does axial high-resolution CT. Most of the patients in that study were scanned with 4-MDCT using a gantry rotation time of.8 sec and a slice width of 1.25 mm. The equipment used in that study had to result in a scanning time of up to 2 sec compared with 6 sec in this study to cover the chest, although no information about scan duration, pitch, or B Fig year-old man with recurrent large cell lymphoma (asterisk) in right middle lobe after stem cell transplantation. Images are displayed at window level of -5 H and width of 1,4 H. A, Image obtained with axial high-resolution CT clearly depicts, in right lower lobe, ground-glass attenuation (arrows) that represents viral infection in this patient undergoing immunosuppressive treatment. B, Corresponding image obtained from volumetric MDCT shows slight blurring of ground-glass attenuation (arrows). Minor cardiac motion artifacts with doubling of pulmonary vessel adjacent to heart (arrowhead) were not considered to compromise image evaluation. table feed was provided. Their technique used a single breath-hold for each image obtained with axial high-resolution CT, whereas we acquired high-resolution CT scans using two or three breath-holds with respiration allowed in between, resulting in a longer breath-hold period (average breath-hold time, 9.7 sec, compared with 6 sec using MDCT) and, consequently, in more motion artifacts. Using our high-resolution CT protocol, the gantry rotation time was.25 sec longer (.75 sec) than the time needed for a 36 tube rotation using the MDCT protocol (.5 sec). However, this slight time difference has little effect on substantial artifacts; if it has any effect, that effect may be on cardiac motion artifacts. In contrast to Kelly et al., we applied a 1-cm spacing interval, resulting in a doubling of the number of images to be interpreted and a more pronounced effect on the statistical analysis. Altogether, the longer scanning time (by three to four times) used for 4-MDCT in the work of Kelly et al. is the most important factor to consider when evaluating the discrepancy between our results and theirs. Schoepf et al. [6] compared the quality of thin-section images obtained from a singledetector scanner to that of reconstructed images obtained from an MDCT scanner and found no significant difference. However, the MDCT scanner they used required a mean duration of 27 sec to cover the entire lung, a situation hardly comparable to that of our study regarding artifacts. Furthermore, because the two techniques were compared in two different patient populations, those results could AJR:185, September 5 65

5 Studler et al. A B Fig year-old man with sarcoidosis. Images are displayed at window level of -5 H and width of 1,4 H. A, Image obtained with axial high-resolution CT shows decreased regional attenuation due to mosaic perfusion (open arrows) and irregular septal thickening (solid arrows). Diffuse small nodules are visible (arrowheads). B, Reconstructed image from MDCT reveals no significant difference in image quality. Focal areas of decreased attenuation (open arrows), septal thickening (solid arrow), and diffuse nodules (arrowheads) are clearly depicted. have been biased. Our study setting permitted both methods to be performed on the same patients, excluding this kind of bias. A significant difference in increased lung attenuation between the two methods indicated that high-resolution CT better depicted the presence of ground-glass attenuation (Fig. 3). We performed MDCT with a collimation of 1.5 mm, for which the thinnest possible image reconstruction is 2 mm. Another option would have been to use the thinner,.75-mm collimation with the same pitch. This protocol offers the advantage of 1-mmthick slice reconstructions and, therefore, may reduce blurring and improve image detail without a significant increase in radiation dose. However, the use of a narrower collimation halves the table speed and increases the tube rotation time, resulting in longer scans and, consequently, more artifacts. In addition, the huge amount of data generated by such protocols becomes increasingly difficult to manage. We believe that the parameters used, including a collimation of 1.5 mm, were appropriate for the imaging quality required, and although image resolution with this protocol was significantly reduced because of ground-glass opacities, neither reviewer considered the overall image quality restricted. The average interobserver variability as measured by weighted kappa was moderate to good for both methods. The two lowest values for either method were in the category artifacts. The values were less than.4, indicating poor agreement. This was attributed to the fact that one reviewer used more rigorous criteria to characterize images containing motion artifacts as nondiagnostic than the other reviewer did. However, kappa values from both methods exceeded chance levels. The calculated effective doses 3.8 and.9 msv for volumetric MDCT and axial high-resolution CT, respectively were similar to those found in other studies [6, 13]. The higher effective dose received from axial high-resolution CT in this study than in the study of Kelley et al. [13] (.9 vs.58 msv) was due to the different spacing intervals in our study and theirs (1 and 2 mm, respectively). A potential limitation of our study was that it was not designed to assess the diagnostic accuracy of images obtained from the two methods. Although all the important high-resolution CT criteria for normal and pathologic lung parenchyma structures were included in the rating, our results are based on subjective image interpretation. An additional limitation of the study involves the different collimations and reconstruction thicknesses used between the two methods. The MDCT collimation of 1.5 mm and the resulting reconstruction slice thickness of 2 mm constitute a compromise between a short examination time and the slice width. The different slice thicknesses soon may be fully compensated for when the faster 32- or 64-MDCT scanners are implemented into routine clinical practice. In summary, the current study has revealed that reconstructed thin-section images of good quality can be obtained using a standard chest MDCT protocol. However, reconstructed thin sections obtained from MDCT cannot be recommended for diseases showing predominantly ground-glass patterns. References 1. Nishimura K, Izumi T, Kitaichi M, Nagai S, Itoh H. The diagnostic accuracy of high-resolution computed tomography in diffuse infiltrative lung disease. Chest 1993; 14: Remy-Jardin M, Remy J, Deffontaines C, Duhamel A. Assessment of diffuse infiltrative lung disease: comparison of conventional CT and high-resolution CT. Radiology 1991; 181: Itoh H, Murata K, Konishi J, Nishimura K, Kitaichi M, Izumi T. Diffuse lung disease: pathologic basis for the high-resolution computed tomography findings. J Thorac Imaging 1993; 8: Kang EY, Miller RR, Muller NL. Bronchiectasis: comparison of preoperative thin-section CT and pathologic findings in resected specimens. Radiology 1995; 195: Murata K, Khan A, Rojas KA, Herman PG. Optimization of computed tomography technique to demonstrate the fine structure of the lung. Invest Radiol 1988; 23: Schoepf UJ, Bruening RD, Hong C, et al. Multislice helical CT of focal and diffuse lung disease: comprehensive diagnosis with reconstruction of contiguous and high-resolution CT sections from a single thin-collimation scan. AJR 1; 177: Honda O, Johkoh T, Tomiyama N, et al. High-res- 66 AJR:185, September 5

6 High-Resolution CT and MDCT of the Lung olution CT using multidetector CT equipment: evaluation of image quality in 11 cadaveric lungs and a phantom. AJR 1; 177: Hu H, He HD, Foley WD, Fox SH. Four multidetector-row helical CT: image quality and volume coverage speed. Radiology ; 215: Silverman PM, Kalender WA, Hazle JD. Common terminology for single and multislice helical CT. AJR 1; 176: Kalender WA, Schmidt B, Zankl M, Schmidt M. A FOR YOUR INFORMATION PC program for estimating organ dose and effective dose values in computed tomography. Eur Radiol 1999; 9: Mahesh M. Search for isotropic resolution in CT from conventional through multiple-row detector. RadioGraphics 2; 22: Schoepf UJ, Costello P. CT angiography for diagnosis of pulmonary embolism: state of the art. Radiology 4; 23: Kelly DM, Hasegawa I, Borders R, Hatabu H, Boiselle PM. High-resolution CT using MDCT: comparison of degree of motion artifact between volumetric and axial methods. AJR 4; 182: Boehm T, Willmann JK, Hilfiker PR, et al. Thinsection CT of the lung: does electrocardiographic triggering influence the diagnosis? Radiology 3; 229: Schoepf UJ, Becker CR, Bruening RD, et al. Electrocardiographically gated thin-section CT of the lung. Radiology 1999; 121: For the convenience of AJR authors, a standardized form requesting permission to reprint from other publications is now available via the ARRS Web site at Your computer system must have version 3. or later of Adobe Acrobat Reader. AJR:185, September 5 67

High-Resolution CT of the Lung

High-Resolution CT of the Lung High-Resolution CT of the Lung High-Resolution CT of the Lung FIFTH EDITION W. Richard Webb, MD Professor Emeritus of Radiology and Biomedical Imaging Emeritus Member, Haile Debas Academy of Medical Educators

More information

Low-dose and High-resolution Cardiovascular Imaging with Revolution* CT

Low-dose and High-resolution Cardiovascular Imaging with Revolution* CT GE Healthcare Case study Low-dose and High-resolution Cardiovascular Imaging with Revolution* CT Jean-Louis Sablayrolles, M.D. Laurent Macron, M.D. Jacques Feignoux, M.D. Centre Cardiologique du Nord,

More information

Computed Tomography: Optimization of acquisition protocols & Justification of clinical referrals. Koos Geleijns, medical physicist

Computed Tomography: Optimization of acquisition protocols & Justification of clinical referrals. Koos Geleijns, medical physicist Computed Tomography: Optimization of acquisition protocols & Justification of clinical referrals Koos Geleijns, medical physicist CT delivers excellent 3D image quality CT delivers excellent 3D image quality

More information

40TH ANNUAL MEETING. CTA Dose Reduction: Special Considerations in Children. Jeffrey C. Hellinger, MD FACC. October 13 16, 2012 Pasadena, CA

40TH ANNUAL MEETING. CTA Dose Reduction: Special Considerations in Children. Jeffrey C. Hellinger, MD FACC. October 13 16, 2012 Pasadena, CA 40TH ANNUAL MEETING October 13 16, 2012 Pasadena, CA CTA Dose Reduction: Special Considerations in Children Jeffrey C. Hellinger, MD FACC New York Cardiovascular Institute Lenox Hill Radiology and Medical

More information

Handzettel 1. CARE Right Computed Tomography, committed to the right dose Ivo Driesser Austin, July 22 nd 2014

Handzettel 1. CARE Right Computed Tomography, committed to the right dose Ivo Driesser Austin, July 22 nd 2014 CARE Right Computed Tomography, committed to the right dose Ivo Driesser Austin, July 22 nd 2014 Answers for life. Answers for life. Is 1 msv the right dose for every patient? Female, 54 Abdominal CT Male,

More information

Fast enough to stop the Capable of delineating Unprecedented imaging power for the. Virtual endoscopy. The gatewa

Fast enough to stop the Capable of delineating Unprecedented imaging power for the. Virtual endoscopy. The gatewa Fast enough to stop the Capable of delineating Unprecedented imaging power for the M U L T I S L I C E Virtual endoscopy The gatewa motion of a beating heart. anatomic structures as small as 0.25mm. earliest,

More information

The FUTURE has ARRIVED NeuViz 128

The FUTURE has ARRIVED NeuViz 128 Contacts Middle East & North Africa No. 705/706, Building 26,Al-Baker Building, Dubai Healthcare City, UAE Tel: +971 4 4404885 North America 14425 Torrey Chase, Suite 100, Houston, TX 77014 Tel: +1 281

More information

Low Dose, Lightning Speed, Latest Applications

Low Dose, Lightning Speed, Latest Applications RXL EDITION Low Dose, Lightning Speed, Latest Applications The New Standard for Radiology Toshiba Medical Systems is committed to the development of new technologies to minimize radiation dose while maintaining

More information

Abdominal CT with Single-Energy Metal Artifact Reduction (SEMAR): Initial Experiences

Abdominal CT with Single-Energy Metal Artifact Reduction (SEMAR): Initial Experiences Abdominal CT with Single-Energy Metal Artifact Reduction (SEMAR): Initial Experiences Poster No.: C-0674 Congress: ECR 2014 Type: Scientific Exhibit Authors: K. Sofue 1, T. Yoshikawa 1, N. Negi 1, Y. Ohno

More information

CTA Throughout the Ages

CTA Throughout the Ages CTA Throughout the Ages Suhny Abbara, MD Associate Professor, Harvard Medical School Director of Education, Cardiac MRCT Program Director Cardiovascular Imaging Fellowship, Massachusetts General Hospital

More information

Clarity CT Technology

Clarity CT Technology Clarity CT Technology WHITE PAPER January 2013 Using state of the art algorithms Sapheneia Clarity CT allows physicians to lower radiation dose when acquiring CT data while maintaining image quality. The

More information

Table of Contents. Adaptive Diagnostics...7 Integrated Dose Reduction Streamlined Workflow Clinical Images... 26

Table of Contents. Adaptive Diagnostics...7 Integrated Dose Reduction Streamlined Workflow Clinical Images... 26 2 Table of Contents Adaptive Diagnostics...7 Integrated Dose Reduction... 17 Streamlined Workflow... 21 Clinical Images... 26 3 AQUILION TM PRIME PROVIDES CLINICAL FLEXIBILITY, ENHANCED WORKFLOW FEATURES

More information

UPICT template structure as modified by QIBA VolCT Technical Committee June 25, 2009

UPICT template structure as modified by QIBA VolCT Technical Committee June 25, 2009 UPICT template structure as modified by QIBA VolCT Technical Committee June 25, 2009 The QIBA VolCT Technical Committee modified and used the UPICT template for a VolCT profile on CT Lung Nodule Volume

More information

8/1/2018. Optimization Strategies for Pediatric CT Imaging. Educational Objectives. Brain CT

8/1/2018. Optimization Strategies for Pediatric CT Imaging. Educational Objectives. Brain CT Image Quality Radiation Dose Contrast Dose Sedation Optimization Strategies for Pediatric CT Imaging Samuel Brady, M.S. Ph.D. DABR samuel.brady@cchmc.org 8-1-218 @CincyKidsRad facebook.com/cincykidsrad

More information

CT post processing and low dose scanning

CT post processing and low dose scanning CT post processing and low dose scanning Gabor Szell GE Healthcare CT Modality Manager EE Annual Scientific and Educational Meeting Innovations in Cardiothoracic Imaging 201 13-14 May 2011, Tokuda Hospital

More information

The Latest in Radiation Dose Reduction Techniques in CT

The Latest in Radiation Dose Reduction Techniques in CT The Latest in Radiation Dose Reduction Techniques in CT Cynthia H. McCollough, PhD, FAAPM, FACR Professor of Radiologic Physics Director, CT Clinical Innovation Center Department of Radiology Mayo Clinic,

More information

AAPM Scientific Meeting Imaging Symposium. State of the Art in Quantitative Imaging CT, PET and MRI. Which Imaging Modality is the Most Quantitative

AAPM Scientific Meeting Imaging Symposium. State of the Art in Quantitative Imaging CT, PET and MRI. Which Imaging Modality is the Most Quantitative AAPM Scientific Meeting Imaging Symposium State of the Art in Quantitative Imaging CT, PET and MRI Michael McNitt-Gray, PhD, FAAPM; UCLA Paul Kinahan, PhD, U. Washington Ed Jackson, PhD, FAAPM, UT-MD Anderson

More information

Computed tomography. High. performance. no trade-offs. Philips Ingenuity CT family

Computed tomography. High. performance. no trade-offs. Philips Ingenuity CT family Computed tomography High performance no trade-offs Philips Ingenuity CT family Keeping you ahead Until now, CT scanning has too often been about trade-offs. You ve been forced to choose between high image

More information

QIBA Profile: Small Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening

QIBA Profile: Small Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening QIBA Profile: Lung Nodule Assessment in CT Screening Profile - 2017 1 2 3 4 5 6 QIBA Profile: Small Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening 7 8 Stage: Publicly Reviewed (draft)

More information

Trusted Performance. Smart Investment. 80 detector row Ultra Helical CT

Trusted Performance. Smart Investment. 80 detector row Ultra Helical CT TM Trusted Performance. Smart Investment. 80 detector row Ultra Helical CT 2 High performance, highly economical Increased productivity and patient safety Maximum clinical capabilities Are you looking

More information

NeuViz 64 In/En. Flagship Product. Contacts

NeuViz 64 In/En. Flagship Product. Contacts Contacts Headquarters Neusoft Medical Systems Co., Ltd. No.16 Shiji Road, Hunnan Industrial Area Shenyang, 110179, Liaoning, China Email: zhang-dan@neusoft.com Africa Neusoft Medical Systems (Africa) Co.

More information

Superficial Endobronchial Lung Cancer: Radiologic-Pathologic Correlation

Superficial Endobronchial Lung Cancer: Radiologic-Pathologic Correlation Superficial Endobronchial Lung Cancer: Radiologic-Pathologic Correlation Nae Jin Han, MD 1 Koun-Sik Song, MD 1 Kyung Hee Lee, MD 1 Joon Beom Seo, MD 1 Jin Seong Lee, MD 1 Tae-Hwan Lim, MD 1 Gil Hyun Kang,

More information

GENESIS Edition Transforming CT

GENESIS Edition Transforming CT GENESIS Edition Transforming CT 2 Transforming clinical confidence Transforming patient experience Transforming your workspace GENESIS Edition Transforming CT Brought to you by the leaders in area detector

More information

QIBA Profile: Small Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening

QIBA Profile: Small Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening QIBA Profile: Small Lung Nodule Assessment in CT Screening Profile - 2017 1 2 3 4 5 6 QIBA Profile: Small Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening 7 8 Stage: Publicly Reviewed

More information

GE Healthcare. Introducing Veo * on Discovery * CT750 HD Great care by design

GE Healthcare. Introducing Veo * on Discovery * CT750 HD Great care by design GE Healthcare Introducing Veo * on Discovery * CT750 HD Great care by design Radiologists and clinicians demand the ultimate levels of clarity and detail in their images. In making an informed and confident

More information

High performance comes easily

High performance comes easily High performance comes easily Philips MX 16-slice CT Easy from any The CT solution Your days may not be getting any easier, but now your CT solution is. The remarkably easy-to-use Philips MX 16-slice CT

More information

GENESIS Edition. Transforming CT

GENESIS Edition. Transforming CT GENESIS Edition Transforming CT Transforming clinical confidence Transforming patient experience Transforming your workspace GENESIS Edition Transforming CT Brought to you by the leaders in area detector

More information

Not for publication in the USA Erlangen, November 26, 2017

Not for publication in the USA Erlangen, November 26, 2017 Press Not for publication in the USA Erlangen, November 26, 2017 RSNA 2017 in Chicago: South Building, Hall A, Booth 1937 strengthens its CT portfolio by improving patient experience and expanding precision

More information

Progress Towards an International Image Quality Monitoring Framework for Quantitative Imaging

Progress Towards an International Image Quality Monitoring Framework for Quantitative Imaging Progress Towards an International Image Quality Monitoring Framework for Quantitative Imaging Ricardo S. Avila rick.avila@accumetra.com October 2, 2017 Quantitative Imaging Workshop XIV Hubble Space Telescope

More information

Jonathon A. Nye, Ph.D Emory University School of Medicine Atlanta, GA

Jonathon A. Nye, Ph.D Emory University School of Medicine Atlanta, GA Artifacts related to CT Jonathon A. Nye, Ph.D Emory University School of Medicine Atlanta, GA Acknowledgements: Fabio Esteves MD 1, James Galt PhD 1, Perry Sprawls PhD 1, Robert Eisner PhD 2, James Hamill

More information

Submillisievert Chest CT With Filtered Back Projection and Iterative Reconstruction Techniques

Submillisievert Chest CT With Filtered Back Projection and Iterative Reconstruction Techniques Cardiopulmonary Imaging Original Research Padole et al. Submillisievert Chest CT Cardiopulmonary Imaging Original Research Atul Padole 1 Sarabjeet Singh Jeanne B. Ackman Carol Wu Synho Do Sarvenaz Pourjabbar

More information

Image-Guided Thoracic Surgery using a Mobile C-Arm for CBCT: Image Quality, Dose, and First Experience in Imaging the Fully Deflated Lung

Image-Guided Thoracic Surgery using a Mobile C-Arm for CBCT: Image Quality, Dose, and First Experience in Imaging the Fully Deflated Lung Image-Guided Thoracic Surgery using a Mobile C-Arm for CBCT: Image Quality, Dose, and First Experience in Imaging the Fully Deflated Lung S Schafer, 1 A Uneri, 1 DJ Mirota, 1 S Nithiananthan, 1 JW Stayman,

More information

NeuViz The NEW Standard in Multi-Slice CT Scanners

NeuViz The NEW Standard in Multi-Slice CT Scanners NeuViz The NEW Standard in Multi-Slice CT Scanners Setting a New Pace in CT Evolution 2012 NeuViz 64 2008 NeuViz 16 2007 Over 1000 CT installations worldwide 2006 NeuViz Dual 2004 Neusoft forms a joint

More information

Comparison of quantitative methods for the assessment of interstitial lung disease in MDCT

Comparison of quantitative methods for the assessment of interstitial lung disease in MDCT Comparison of quantitative methods for the assessment of interstitial lung disease in MDCT Award: Certificate of Merit Poster No.: C-0140 Congress: ECR 2014 Type: Scientific Exhibit Authors: N. Papapanagiotou,

More information

Leading Canadian Pediatric Hospital Continues to Drive Dose Down for Sick Children

Leading Canadian Pediatric Hospital Continues to Drive Dose Down for Sick Children Leading Canadian Pediatric Hospital Continues to Drive Dose Down for Sick Children At Canada s premier pediatric hospital also recognized as one of the world s foremost pediatric healthcare institutions

More information

Percutaneous transthoracic needle biopsy of pulmonary nodules under XperGuide cone-beam CT guidance

Percutaneous transthoracic needle biopsy of pulmonary nodules under XperGuide cone-beam CT guidance Clinical applications Percutaneous transthoracic needle biopsy of pulmonary nodules under XperGuide cone-beam CT guidance G. Carrafiello F. Fontana M. Mangini F. Piacentino A. Cani C. Pellegrino C. Fugazzola

More information

Excellence in CT. SOMATOM Definition.

Excellence in CT. SOMATOM Definition. Excellence in CT SOMATOM Definition www.siemens.com/medical Contents SOMATOM Definition Dual Source CT Faster than Every Beating Heart Full Cardiac Detail at Half the Dose One-Stop Diagnosis in Acute

More information

2017 ACR Computed Tomography Quality Control Manual FAQS

2017 ACR Computed Tomography Quality Control Manual FAQS Updated 11-15-2017 2017 ACR Computed Tomography Quality Control Manual FAQS Q. The updated 2017 ACR Computed Tomography Quality Control Manual has been released. (Visit www.acr.org/education/education-catalog.)

More information

Dual Source Flash Spiral for a scan speed of 458 mm/s

Dual Source Flash Spiral for a scan speed of 458 mm/s Core Technologies Dual Source Flash Spiral for a scan speed of 458 mm/s With Flash Spiral, dose values under 1 msv especially important for the most dose-sensitive patients are so frequent they can be

More information

low Dose, Lightning Speed

low Dose, Lightning Speed CXL edition low Dose, Lightning Speed Maximize the potential of today s clinical resources. In today s demanding healthcare environment, you need a CT system that satisfies all your requirements on a day-to-day

More information

Patient doses from CT examinations in region of Prishtina, Kosovo

Patient doses from CT examinations in region of Prishtina, Kosovo Patient doses from CT examinations in region of Prishtina, Kosovo Sehad KADIRI, Gëzim HODOLLI, Kostandin DOLLANI Institute of Occupational Medicine, Radiation Protection Service, Obiliq, Kosovo Institute

More information

Purpose. Methods and Materials

Purpose. Methods and Materials MR cholangiopancreatography: Comparison between 3D fast recovery fast spin echo and 2D single shot fast spin echo sequences in the evaluation of choledocholithiasis. Poster No.: C-1193 Congress: ECR 2012

More information

The World s First Adaptive Scanner

The World s First Adaptive Scanner The World s First Adaptive Scanner SOMATOM Definition AS Excel Edition Answers for life. SOMATOM Definition AS Excel Edition 2 3 Siemens CT Vision Siemens CT Vision The justification for the existence

More information

A New Standard for the Future

A New Standard for the Future technology history For over 130 years, Toshiba has been a world leader in developing technology to improve the quality of life. Our 50,000 global patents demonstrate a long, rich history of leading innovation.

More information

Making Reliable Low-dose CT a Clinical Reality

Making Reliable Low-dose CT a Clinical Reality Making Reliable Low-dose CT a Clinical Reality By Ramakrishnan RS, MD, DNB, Consultant Radiologist 1 ; George Joseph, MD, DMRD, Consultant Radiologist 2 ; and Sundar RK, BSc, DRT, DAMIT, Clinical Applications

More information

Optimisation in CT. A case for shared approach. Stephen J. Golding University of Oxford

Optimisation in CT. A case for shared approach. Stephen J. Golding University of Oxford Optimisation in CT A case for shared approach Stephen J. Golding University of Oxford Body CT 1979: 10 mm sections 20 second exposure 60 second reconstruction Body CT 2007 Submillimetre sections instant

More information

SPECIFICATION CT SIMULATOR FOR BLACK LION HOSPITAL, ADDIS ABEBA, ETHIOPIA

SPECIFICATION CT SIMULATOR FOR BLACK LION HOSPITAL, ADDIS ABEBA, ETHIOPIA SPECIFICATION CT SIMULATOR FOR BLACK LION HOSPITAL, ADDIS ABEBA, ETHIOPIA 1. Scope This specification describes the requirements for the supply, delivery, installation, and acceptance testing of a CT Simulator

More information

I M A G E G U I D E D R A D I A T I O N T H E R A P Y. Elekta XVI. Inspiring clinical confidence

I M A G E G U I D E D R A D I A T I O N T H E R A P Y. Elekta XVI. Inspiring clinical confidence I M A G E G U I D E D R A D I A T I O N T H E R A P Y Elekta XVI Inspiring clinical confidence 1 New levels of precision and accuracy Tumor target motion is a significant factor in inhibiting increasing

More information

Future bound. Philips Ingenuity Core

Future bound. Philips Ingenuity Core Future bound Philips Ingenuity Core High reliability Low-dose, high-quality imaging and coverage, and the ability to personalize image quality* patient by patient. Expect excellence in routine imaging,

More information

PRINCIPLES OF CT AND MR IMAGING Marc-André d Anjou, DMV, DACVR Faculty of Veterinary Medicine, University of Montreal Saint-Hyacinthe, Quebec, Canada

PRINCIPLES OF CT AND MR IMAGING Marc-André d Anjou, DMV, DACVR Faculty of Veterinary Medicine, University of Montreal Saint-Hyacinthe, Quebec, Canada PRINCIPLES OF CT AND MR IMAGING Marc-André d Anjou, DMV, DACVR Faculty of Veterinary Medicine, University of Montreal Saint-Hyacinthe, Quebec, Canada CT and MR imaging offer superior diagnostic possibilities

More information

Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose

Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose ipatient is an advanced platform that delivers focused innovations to facilitate patient-centered

More information

Effect of Thin Overlapping Reconstruction on the Attenuation of Small ( 3 cm) Renal Cysts in the Nephrographic Phase of MDCT: a Phantom Study

Effect of Thin Overlapping Reconstruction on the Attenuation of Small ( 3 cm) Renal Cysts in the Nephrographic Phase of MDCT: a Phantom Study Effect of Thin Overlapping Reconstruction on the Attenuation of Small ( 3 cm) Renal Cysts in the Nephrographic Phase of MDCT: a Phantom Study Sun Ho Kim, MD 1, 2 Seung Hyup Kim, MD 1 Index terms: Kidney

More information

THE NEW 640 SLICE CT SCANNER

THE NEW 640 SLICE CT SCANNER THE NEW 640 SLICE CT SCANNER www.ahdubai.com The American Hospital Dubai has recently acquired a state-ofthe-art computerized tomography (CT) scanner that houses a variety of intelligent and industry-leading

More information

More flexibility More performance Less dose

More flexibility More performance Less dose 2010 General Electric Company All rights reserved. GE and GE Monogram are trademarks of General Electric Company. GE Healthcare ASiR, Performix, microvoxel, Volara, and SmartView are trademarks of General

More information

Adaptive Iterative Dose Reduction in 3D

Adaptive Iterative Dose Reduction in 3D technology history For over 130 years, Toshiba has been a world leader in developing technology to improve the quality of life. Our 50,000 global patents demonstrate a long, rich history of leading innovation.

More information

The time has come. Philips GEMINI TF PET/CT with TruFlight technology

The time has come. Philips GEMINI TF PET/CT with TruFlight technology The time has come Philips GEMINI TF PET/CT with TruFlight technology TruFlight has arrived Time-of-flight technology has always held the promise of better PET imaging. But it took Philips to harness its

More information

Clinical Applications of the Latest Ultra-High-Resolution CT and Iterative Reconstruction Algorithm: Things Radiologist and Radiographer Need to Know

Clinical Applications of the Latest Ultra-High-Resolution CT and Iterative Reconstruction Algorithm: Things Radiologist and Radiographer Need to Know Clinical Applications of the Latest Ultra-High-Resolution CT and Iterative Reconstruction Algorithm: Things Radiologist and Radiographer Need to Know Poster No.: C-1477 Congress: ECR 2018 Type: Educational

More information

COMPARATIVE ANALYSIS BETWEEN TWO AUTOMATIC SYSTEMS FOR LUNGS SEGMENTATION AND QUANTIFICATION FROM CT IMAGES OF HEALTHY PERSONS AND PATIENTS WITH COPD

COMPARATIVE ANALYSIS BETWEEN TWO AUTOMATIC SYSTEMS FOR LUNGS SEGMENTATION AND QUANTIFICATION FROM CT IMAGES OF HEALTHY PERSONS AND PATIENTS WITH COPD COMPARATIVE ANALYSIS BETWEEN TWO AUTOMATIC SYSTEMS FOR LUNGS SEGMENTATION AND QUANTIFICATION FROM CT IMAGES OF HEALTHY PERSONS AND PATIENTS WITH COPD John H.S. Felix 1, P.C. Cortez 1, João Manuel R. S.

More information

During pulmonary resection surgeons occasionally. Use of Three-Dimensional Computed Tomographic Angiography of Pulmonary Vessels for Lung Resections

During pulmonary resection surgeons occasionally. Use of Three-Dimensional Computed Tomographic Angiography of Pulmonary Vessels for Lung Resections Use of Three-Dimensional Computed Tomographic Angiography of Pulmonary Vessels for Lung Resections Shun-ichi Watanabe, MD, Kazunori Arai, MD, Toshio Watanabe, MD, Wataru Koda, MD, and Hiroshi Urayama,

More information

IAEA-TECDOC Dose Reduction in CT while Maintaining Diagnostic Confidence: A Feasibility/Demonstration Study

IAEA-TECDOC Dose Reduction in CT while Maintaining Diagnostic Confidence: A Feasibility/Demonstration Study IAEA-TECDOC-1621 Dose Reduction in CT while Maintaining Diagnostic Confidence: A Feasibility/Demonstration Study IAEA-TECDOC-1621 Dose Reduction in CT while Maintaining Diagnostic Confidence: A Feasibility/Demonstration

More information

GE Healthcare. Revolution GSI. A Better Exam.

GE Healthcare. Revolution GSI. A Better Exam. GE Healthcare Revolution GSI A Better Exam. Put yourself instantly at the forefront of spectral CT. Revolution* GSI is a new generation of CT that delivers consistently high-definition imaging, for confident

More information

1. Executive Summary

1. Executive Summary 1. Executive Summary 1.1 General The fluoroscope is defined as an instrument used chiefly in industry and in the practice of medicine for observing the internal structure of objects (such as the living

More information

CT Cystogram CT Pelvis WO

CT Cystogram CT Pelvis WO CT Cystogram CT Pelvis WO Reviewed By: Rachael Edwards, MD; Anna Ellermeier, MD; Brett Mollard, MD Last Reviewed: January 2019 Contact: (866) 761-4200, Option 1 In accordance with the ALARA principle,

More information

Creating a More Efficient Workflow for Reading High-Volume CT and MR Studies

Creating a More Efficient Workflow for Reading High-Volume CT and MR Studies Creating a More Efficient Workflow for Reading High-Volume CT and MR Studies Summary Advancement in modality technologies has brought benefits to radiology, such as quicker image capture and enhanced image

More information

www.aquilionprime.com WARNING: Any reference to x-ray exposure, intravenous contrast dosage, and other medication is intended as a reference guideline only. The guidelines in this document do not substitute

More information

Respiratory-phase phase correlated imaging, treatment planning and delivery Clinical Implementation. Disclosures. Session Objectives.

Respiratory-phase phase correlated imaging, treatment planning and delivery Clinical Implementation. Disclosures. Session Objectives. Respiratory-phase phase correlated imaging, treatment planning and delivery Clinical Implementation None Disclosures Sastry Vedam Assistant Professor Department of Radiation Physics AAPM Annual Meeting

More information

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident Resident s Name: RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident Rotation: PHYS 705: Clinical Rotation 3 Inclusive dates of rotation: Aug. 25, 2015 Feb. 25, 2016 Director or Associate

More information

Advanced digital radiographic system powered by FlashPad.

Advanced digital radiographic system powered by FlashPad. GE Healthcare Discovery XR656 Plus Advanced digital radiographic system powered by FlashPad. Step up to the world of freedom. Discovery* XR656 Plus lets you enjoy productivity and workflow benefits thanks

More information

Computed Tomography. Printed in Japan

Computed Tomography. Printed in Japan Computed Tomography WARNING: Any reference to x-ray exposure, intravenous contrast dosage, and other medication is intended as a reference guideline only. The guidelines in this document do not substitute

More information

Optima * CT520 Personalized CT solution

Optima * CT520 Personalized CT solution GE Healthcare Optima * CT520 Personalized CT solution Not for use or distribution in the United States Broader vis Fast acquisition, reconstruction, and post-processing meet clinical and workflow challenges.

More information

Making the difference with Live Image Guidance

Making the difference with Live Image Guidance OncoSuite Interventional X-ray Making the difference with Live Image Guidance Next generation of Image Guided Therapy in Interventional Oncology Live Image Guidance in Interventional Oncology OncoSuite:

More information

7/28/2017. Michael Speidel. University of Wisconsin - Madison

7/28/2017. Michael Speidel. University of Wisconsin - Madison Scanning-Beam Digital X-ray (SBDX) is a technology for real-time fluoroscopy and angiography in the cardiac cath lab Michael Speidel Characterized by high speed beam scanning with a 2D array of focal spots

More information

Optimization of image quality and radiation dose in neuroradiological computed tomography

Optimization of image quality and radiation dose in neuroradiological computed tomography Optimization of image quality and radiation dose in neuroradiological computed tomography Löve, Askell 2013 Link to publication Citation for published version (APA): Löve, A. (2013). Optimization of image

More information

NeuViz. Computed TomographyPrime. Advanced, Value-Rich 128-Slice CT Technology

NeuViz. Computed TomographyPrime. Advanced, Value-Rich 128-Slice CT Technology NeuViz Computed TomographyPrime Advanced, Value-Rich 128-Slice CT Technology Prime NeuViz Value-based healthcare, a new financial challenge Make your imaging budget go further. Hospitals are faced with

More information

Frequently Asked Questions (FAQ's)

Frequently Asked Questions (FAQ's) Frequently Asked Questions (FAQ's) Critical Comments on Proper Patient Centering 1. Using the UW protocols, I sometimes find that parts of the image are too noisy, particularly towards the posterior part

More information

Patient radiation dose and image quality optimization in CT. Optimiser la dose patient et la qualité image en scanner

Patient radiation dose and image quality optimization in CT. Optimiser la dose patient et la qualité image en scanner Conférence SPIMED - 8 juin 2012 IQ Patient safety Dose Reduction Patient radiation dose and image quality optimization in CT Optimiser la dose patient et la qualité image en scanner Philippe Coulon, PhD.

More information

Various Iterative Reconstruction Techniques in Chest CT: Impact for Interstitial Lung Disease under Low-dose Condition

Various Iterative Reconstruction Techniques in Chest CT: Impact for Interstitial Lung Disease under Low-dose Condition Various Iterative Reconstruction Techniques in Chest CT: Impact for Interstitial Lung Disease under Low-dose Condition Poster No.: C-1803 Congress: ECR 2018 Type: Scientific Exhibit Authors: M. Kim, M.

More information

Precision in Quantitative Imaging: Trial Development and Quality Assurance

Precision in Quantitative Imaging: Trial Development and Quality Assurance Precision in Quantitative Imaging: Trial Development and Quality Assurance Susanna I Lee MD, PhD Thanks to: Mitchell Schnall, Mark Rosen. Dan Sullivan, Patrick Bossuyt Imaging Chain: Patient Data Raw data

More information

Motiva: a TV-based platform for remote patient management

Motiva: a TV-based platform for remote patient management Technology news New products Motiva: a TV-based platform for remote patient management a simplified user interface, a secure broadband connection and a standard set-top box. A nurse care manager, using

More information

Optimization of Parameters in 16-slice CT-scan Protocols for Reduction of the Absorbed Dose

Optimization of Parameters in 16-slice CT-scan Protocols for Reduction of the Absorbed Dose Iranian Journal of Medical Physics Vol. 11, No. 2 & 3, Spring & Summer 2014, 270-275 Received: March 10, 2014; Accepted: April 27, 2014 Original Article Optimization of Parameters in 16-slice CT-scan Protocols

More information

Customer Experience Insight

Customer Experience Insight Customer Experience Insight Exceeded Contrast Dose Threshold - CT Key Takeaways Using anonymized data collected by the Radimetrics Enterprise Platform we identified a customer with a contrast dose outlier

More information

GE Healthcare. Optima * CT660 Second Edition

GE Healthcare. Optima * CT660 Second Edition GE Healthcare Optima * CT660 Second Edition Your vision of quality care made real The Optima CT660 system helps you deliver competent, personalized care that helps fulfill your mission and please your

More information

Ultrasound diagnosis of pneumothorax after Fine Needle Aspiration of the lung

Ultrasound diagnosis of pneumothorax after Fine Needle Aspiration of the lung Ultrasound diagnosis of pneumothorax after Fine Needle Aspiration of the lung Poster No.: C-0727 Congress: ECR 2013 Type: Scientific Exhibit Authors: A. Lasarte Izcue, J. M. Navasa Melado, R. Pellón, G.

More information

Radiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology

Radiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology Radiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology Multi-Energy Computed Tomography - New Opportunities In Imaging the Abdomen Materials can be

More information

Interventional Tumor Therapy Minimally Invasive, Maximally Effective

Interventional Tumor Therapy Minimally Invasive, Maximally Effective Cover Story Interventional Oncology Interventional Tumor Therapy Minimally Invasive, Maximally Effective There is a continuous expansion of indications for interventional therapies in oncology. Thanks

More information

Innomed Medical Inc. development for healthcare. Ákos Horváth. Senior Project Manager Image Processing Department of X-Ray Systems

Innomed Medical Inc. development for healthcare. Ákos Horváth. Senior Project Manager Image Processing Department of X-Ray Systems Innomed Medical Inc. development for healthcare Ákos Horváth Senior Project Manager Image Processing Department of X-Ray Systems horvath.akos@innomed.hu Table of contents Content Innomed history Main competences

More information

Performance in CT SOMATOM Sensation

Performance in CT SOMATOM Sensation Performance in CT SOMATOM Sensation With the SOMATOM Sensation and z-sharp Technology, the future of volume imaging for cardiac and noncardiac applications has arrived. This scanner is the standard to

More information

Your diagnostic partner. Every day. Optima* CT540

Your diagnostic partner. Every day. Optima* CT540 GE Healthcare Your diagnostic partner. Every day. Optima* CT540 At GE Healthcare, the goal was to design a CT system that would provide our clinical partners with the imaging capabilities needed every

More information

measurement of 3D resolution. The research studies within these recent abstracts are being prepared for submission to various publications.

measurement of 3D resolution. The research studies within these recent abstracts are being prepared for submission to various publications. This document provides a detailed response from the QIBA CT Small Lung Nodule Profile Task Force (TF) to the concerns raised by Mike McNitt-Gray sent on September 11, 2017. The text in black color below

More information

On the Importance of Computation in Clinical Radiology

On the Importance of Computation in Clinical Radiology On the Importance of Computation in Clinical Radiology Manuel Arreola, Ph.D., DABR Director of Radiological Physics Radiology Department University of Florida/Shands Healthcare My Disclaimer I ve received

More information

Quantitative biomarker for clinical decision making

Quantitative biomarker for clinical decision making Deep imaging Quantitative biomarker for clinical decision making Joerg Aumueller English, October 2017 54% of healthcare leaders see an expanding role of in medical decision support.* * The future of healthcare

More information

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method Iran. J. Radiat. Res., 2004; 1(4): 187-194 Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method M.R. Ay 1, M. Shahriari 2, S. Sarkar 3, P.

More information

MEASURING RADIATION DOSE IN COMPUTED TOMOGRAPHY USING ELLIPTIC PHANTOM AND FREE-IN-AIR, AND EVALUATING ITERATIVE METAL ARTIFACT REDUCTION ALGORITHM

MEASURING RADIATION DOSE IN COMPUTED TOMOGRAPHY USING ELLIPTIC PHANTOM AND FREE-IN-AIR, AND EVALUATING ITERATIVE METAL ARTIFACT REDUCTION ALGORITHM MEASURING RADIATION DOSE IN COMPUTED TOMOGRAPHY USING ELLIPTIC PHANTOM AND FREE-IN-AIR, AND EVALUATING ITERATIVE METAL ARTIFACT REDUCTION ALGORITHM ASHRAF MORGAN Bachelor of Science in Physics Cleveland

More information

Image Gently Development of Pediatric CT Protocols 2014

Image Gently Development of Pediatric CT Protocols 2014 Image Gently Development of Pediatric CT Protocols 2014 Introduction In 2001, several scientific articles[1-3] in the radiology literature received considerable media attention by pointing out that using

More information

Power of BRANSIST safire in Neuroendovascular Therapy

Power of BRANSIST safire in Neuroendovascular Therapy Vascular Power of BRANSIST safire in Neuroendovascular Therapy Department of Radiology, Kinki University Hospital Suguru Ueda Mr. Suguru Ueda 1. Introduction Kinki University Hospital is located in the

More information

www.aquilionprime.com WARNING: Any reference to x-ray exposure, intravenous contrast dosage, and other medication is intended as a reference guideline only. The guidelines in this document do not substitute

More information

Size-based protocol optimization using automatic tube current modulation and automatic kv selection in computed tomography

Size-based protocol optimization using automatic tube current modulation and automatic kv selection in computed tomography JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 1, 2016 Size-based protocol optimization using automatic tube current modulation and automatic kv selection in computed tomography Robert

More information

Breast Reconstruction Using Patients Own Tissue Based on CT Angiography and 3-D Surface Scanning

Breast Reconstruction Using Patients Own Tissue Based on CT Angiography and 3-D Surface Scanning Breast Reconstruction Using Patients Own Tissue Based on CT Angiography and 3-D Surface Scanning Jalil JALALI 1, Maximilian EDER 2, Stefan RAITH 2, Alexander VOLF 2, Fee von WALDENFELS 2, Laszlo KOVACS

More information

Your diagnostic partner. Every day. Optima* CT540

Your diagnostic partner. Every day. Optima* CT540 GE Healthcare Your diagnostic partner. Every day. Optima* CT540 At GE Healthcare, the goal was to design a CT system that would provide our clinical partners with the imaging capabilities needed every

More information

A.K. Because edema should have attenuation of around zero Hounsfield units. D.A.B. Around water? A.K. Around water, yes.

A.K. Because edema should have attenuation of around zero Hounsfield units. D.A.B. Around water? A.K. Around water, yes. Multiple Myeloma and Dual-Energy CT: Diagnostic Accuracy of Virtual Noncalcium Technique for Detection of Bone Marrow Infiltration of the Spine and Pelvis Radiology 2018; 286:205 213 Aleksander Kosmala,

More information