imagination at work Sievers Certified Reference Materials and Consumables Catalog GE Power & Water Water & Process Technologies

Size: px
Start display at page:

Download "imagination at work Sievers Certified Reference Materials and Consumables Catalog GE Power & Water Water & Process Technologies"

Transcription

1 GE Power & Water Water & Process Technologies Analytical Instruments Sievers Certified Reference Materials and Consumables Catalog imagination at work imagination at work

2 Sievers Certified Reference Materials and Consumables For more than 20 years, thousands of customers worldwide have relied on Sievers* Total Organic Carbon (TOC) Analyzers, Certified Reference Materials (Sievers Standards), and Consumables for their critical TOC measurement needs. GE Analytical Instruments, the recognized world leader in designing and manufacturing TOC measurement technology, combines this expertise with the renowned Six Sigma methodology to ensure the finest quality in its standards and consumables. Sievers Standards and Consumables provide unmatched performance and reliability in the marketplace. Sievers ready-to-use Standards are designed for calibration, validation, system suitability, and compendial test applications, and can be used with most other TOC analyzer brands. We also offer Certified (<10 ppb) TOC Vials, TOC Sample Vials for process monitoring, consumables, and replacement parts for Sievers TOC Analyzers. TO ORDER: ASIA PACIFIC E:

3 SIEVERS CERTIFIED REFERENCE MATERIALS AND CONSUMABLES Contents About Sievers Certified Reference Materials and Consumables Sievers Standards Benefits Sievers Standards Products and Applications How To Order Sievers Certified Reference Materials and Reagents Sievers Certified Reference Materials Sievers 900 Series TOC Analyzer Standards Sievers 500 RL Series TOC Analyzer Standards Sievers 5310 C Series TOC Analyzer Standards CheckPoint TOC Sensor Standards Sievers InnovOx Series TOC Analyzer Standards Sievers 860 TOC Analyzer Standards for Other TOC Analyzer Brands / Custom Standards TOC Sample Vials, Containers, and Cleaning Validation Kits Sample Vials, Containers, and Cleaning Validation Kits 23 Consumables, Reagents, and Replacement Parts Sievers 900 / 5310 C Series TOC Analyzers Sievers 500 RL / 860 Series TOC Analyzers Sievers InnovOx Series TOC Analyzers CheckPoint TOC Sensor Index of Products Sievers Certified Reference Materials and Reagents TOC Sample Vials, Containers, and Cleaning Validation Kits Consumables, Reagents, and Replacement Parts How To Order AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 2

4 Sievers Standards Benefits Certified and Traceable With extensive expertise in supporting the pharmaceutical market, GE Analytical Instruments understands how critical compliance and traceability are when using analytical standards. Documentation for our certified and traceable reference materials is important in supporting your data and building confidence in your measurement results. To provide a base for your internal documentation needs, we supply a Certificate of Analysis with each standard that documents source material traceability, the accuracy of the solution, and the statistical uncertainty of measurement associated with production. To provide our customers with the highest level of confidence and the traceability they need, Sievers Standards are prepared from the highest purity raw materials available. Source materials for system suitability standards are traceable to the United States Pharmacopeial Convention (USP). Materials for Japanese Pharmacopoeia testing comply with the required specifications for purity. Other standards for calibration and validation are traceable to National Institute of Standards and Technology (NIST) Reference Materials. In addition, laboratory equipment and glassware are traceable to NIST. Stringent Quality Control GE Analytical Instruments makes continuous advancements in the materials science, contamination control procedures, automated processes, and clean room conditions required to produce sensitive, low-level reference materials and consumables. GE Analytical Instruments: Prepares Sievers Standards in accordance with USP Chapter <643>, USP Chapter <645>, EP Method <2.2.44>, and JP Method <2.59>. Produces Sievers Reference Materials in a class 100,000 clean room to minimize contamination. This standards manufacturing process is unique to the market. Uses only the highest grade raw materials (USP and NIST) available which have undergone rigorous quality control. Limits human error by using advanced, custom-designed, automated manufacturing throughout production. Incorporates the world-class Six Sigma methodology in an ISO 9001 environment with our manufacturing processes, while applying additional guidelines from ISO specific to reference material production. 3 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

5 SIEVERS CERTIFIED REFERENCE MATERIALS AND CONSUMABLES BENEFITS Value and Convenience The Sievers Standards Production Lab (see page 7) not only allows GE Analytical Instruments to maintain the most rigorous TOC standards manufacturing process in the industry, but also enables us to produce standards on a large scale. As a result, our customers benefit from significant cost savings. Moreover, Sievers Standards are designed to maximize productivity when used with Sievers TOC Analyzers. With no preparation required and an extended shelf life, these ready-to-use materials are available when you need them. With the convenience of overnight delivery and confidence that comes with GE Analytical Instruments guaranteed performance, Sievers Standards and Consumables are the logical choice for your business. Flexible Ordering and Delivery For your convenience, GE Analytical Instruments offers several programs and ordering methods to fit your needs. The Annual Blanket Standards Order allows you to minimize paperwork and delivery scheduling and save money. With a single purchase order, you can schedule a full year of standards shipments and rest assured they will arrive when needed. North American customers can also take advantage of our on-line store to conveniently order standards 24/7. (See page 8 for details on ordering.) Sievers Standards for all TOC Instruments The Sievers Standards product line is designed for all Sievers TOC instruments, as well as other instrument brands, including Shimadzu, OI Analytical, Skalar, and Teledyne-Tekmar. Custom standards are also available on request. (See page 20 for additional information.) Why risk the performance of your critical instrumentation and the quality of measurement when you can rely on Sievers Standards? Guaranteed Consumables and Replacement Parts GE Analytical Instruments provides consumables, reagents, and replacement parts that are certified and designed specific to our instrumentation. As the Original Equipment Manufacturer we provide warranty options and guarantees on consumables, reagents, and parts quality. AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 4

6 Sievers Standards Products and Applications System Suitability and Compendial Test Standards GE Analytical Instruments can help you design a system suitability test program that meets your internal needs and satisfies compendial requirements. Only GE Analytical Instruments offers a complete TOC validation standard set in alignment with ICH Q2 (R1) guidance. System suitability sets are prepared in accordance with USP Chapter <643> and include 500-ppb 1,4-benzoquinone and sucrose solutions along with the associated reagent water blank. Sets are available for the Sievers 900, 500 RL, CheckPoint, 800, 2244, and 400 Series TOC instruments. System suitability standards are also available for use with other manufacturers TOC instruments. These standards allow users to comply not only with USP Chapter <643>, but also with European Pharmacopoeia (EP) <2.2.44>, Chinese Pharmacopoeia (ChP) Appendix VIII R, and Indian Pharmacopoeia (IP) <2.59>. The Japanese Pharmacopoeia requires the use of SDBS (Sodium Dodecyl Benzene Sulfonate) as the challenge of the TOC method. GE Analytical Instruments is the first company to offer reference materials to support the new Japanese Pharmacopoeia TOC requirements. 5 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

7 SIEVERS CERTIFIED REFERENCE MATERIALS AND CONSUMABLES PRODUCTS AND APPLICATIONS Calibration and Verification Standards Sets The purpose of instrument calibration is to minimize bias. Proper calibration is the critical first step to good instrument performance. Sievers Certified Reference Materials will ensure the optimal calibration of your TOC analyzer per GE Analytical Instruments recommendations. GE Analytical Instruments offers a full line of TOC and conductivity calibration standards for a variety of instruments and applications. For on-line instruments designed exclusively for high-purity water applications, specially-prepared Sievers Conductivity Standards are available. For laboratory instruments, such as the Sievers 800, 900, and 5310 C Series, Sievers Calibration Sets include both inorganic carbon and total carbon standards. Verification Standards Sets Verification standard sets are typically run if a change is made to the instrument or after maintenance. Calibration curve verification should be conducted on a regular basis with one or more standards within the linear range. GE Analytical Instruments offers a host of verification standards at concentrations across the operating range to demonstrate the accuracy and precision of the measurement system. Validation Standards Sets Validation standards are reference materials used for analytical instrument qualification. They help assure that the measurement system meets specifications and that it is suitable for its intended purpose. Validation is a critical component of a quality management system, cgmps, and regulatory compliance. The Sievers Validation Standards Sets comprehensively address LOD, LOQ, linearity, precision, accuracy, specificity, and robustness as detailed in Sievers validation documentation. Each standards set is specifically designed for the individual instrument and its application. AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 6

8 C Lab Equipment 3-Step Water System A B C Pretreatment Primary Purification Proprietary Polishing E 5 B A 4 H D 6 H F 2 1 G 3 Production Facility Floor Plan 1 - Stock Room 2 - Glassware Cleaning Room 3 - Pressurized Airlock 4 - Main Cleanroom Area 5 - Weighing Room 6 - Product Transfer Room D E F G H Automated Glassware Cleaning Weighing Equipment Automatic Vial Fillers Vial Filling Station Air-lock Pass-through Windows Sievers Standards Production Lab Committed to the highest quality, GE Analytical Instruments manufactures Sievers Standards in a stringent cleanroom environment designed to Class 100,000 specifications and using ISO 9001 and guidelines. Cleanroom and manufacturing processes have been designed to minimize contamination risks at each step in the production of the standards, using rigorous contamination control protocols, proprietary glassware cleaning methods, and custom-designed automated equipment. 7 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

9 SIEVERS CERTIFIED REFERENCE MATERIALS AND CONSUMABLES HOW TO ORDER How To Order The Americas Tel: or Fax: Send purchase orders to Send general inquiries to Web Store: Office Hours: Monday through Friday, 10:00 am - 7:00 pm (EST) Europe, Middle East and Africa What to Expect from Sievers Standards and Consumables Premium performance and accuracy Certified, traceable, and guaranteed Convenient and available whenever you need them (next-day delivery for most shipments) Savings in time, effort, operating budget, and avoidance of costly failures with these ready-to-use products U.K. (European Headquarters) Tel: +44 (0) Fax: +44 (0) geai.europe@ge.com Austria Tel: Fax: France Tel: Numéro vert Fax: Asia Pacific All Countries geai.asia@ge.com China Tel: +(8621) Fax: +(8621) geai.china@ge.com India Tel: geai.india@ge.com Japan geai.japan@ge.com Germany Tel: Fax: Ireland Tel: or Fax: or Credit Cards We accept Visa, MasterCard, and American Express. Rapid Shipping Same day shipping is available for most products in North America and Europe. GE Analytical Instruments can deliver your product throughout the world from one of our standards and consumables manufacturing facilities in the US, UK, China, and India. AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 8

10 Sievers Certified Reference Materials The 900 Series Analyzers offer unsurpassed ease of use, analytical performance, versatility, and reliability, and are designed to meet diverse application needs and regulatory requirements. The 900 Series is available in three models the 900 Laboratory, the 900 On-Line, and the 900 Portable. This sections lists the most commonly ordered standards for the 900 Series. See pages for a comprehensive list of Sievers Standards. We run two shifts in the QC laboratory to support the production of a multi-million dollar drug. We can t afford any mistakes with system suitability testing because it would slow down production. That s why we use Sievers Standards. - Analytical Chemistry Manager, API Manufacturer GE Autosampler Sievers 900 Laboratory TOC Analyzer Sievers 900 On-Line TOC Analyzer 9 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

11 SIEVERS CERTIFIED REFERENCE MATERIALS SIEVERS 900 SERIES Sievers 900 Series How often should I Conduct a System Suitability Test? The frequency of system suitability testing is at the user s discretion, and really depends on the level of risk the user is willing to accept. Some users do a System Suitability Test before and after each batch, and some do weekly or monthly checks depending on their risk assessment. GE Analytical Instruments can help you design a test program that meets your internal needs and satisfies compendial requirements. System Suitability and Compendial Standards The United States Pharmacopeia (USP) Chapter <643>, European Pharmacopoeia (EP) Method <2.2.44>, Chinese Pharmacopoeia Appendix VIII R, and Indian Pharmacopoeia <2.4.30> require the analysis of sucrose and benzoquinone to demonstrate system suitability for TOC analysis. The Japanese Pharmacopoeia requires the use of SDBS (Sodium Dodecyl Benzene Sulfonate) as the test compound. GE Analytical Instruments offers certified reference materials to meet these test needs. Following are the most frequently used standards. For a full list, see pages When ordering kits, please use the applicable part number and quantity. System Suitability (40-mL vials) GE Analytical Instruments is the first company to offer reference materials to support the Japanese Pharmacopoeia TOC requirements. STD KIT8D STD KIT8W CSTD Annual Pharmaceutical Standards Kit for Daily Testing 260 x CSTD (System Suitability Set) 10 sets shipped every two weeks. System Suitability Set includes: (1) Reagent Water Control (Rw), (1) Standard Solution (Rs), and (1) System Suitability Solution (Rss). Annual Pharmaceutical Standards Kit for Weekly Testing 52 x CSTD (System Suitability Set) Two sets shipped every two weeks. System Suitability Set includes: (1) Reagent Water Control (Rw), (1) Standard Solution (Rs), and (1) System Suitability Solution (Rss). System Suitability Set Set includes three vials: (1) Rw - Reagent Water Control, (1) Rs µg C/L as USP Sucrose, and (1) Rss 500-µg C/L as USP 1,4 benzoquinone. Japanese Pharmacopoeia (JP) Testing (40-mL vials) CSTD JP Protocol Standard Set Standard set to meet new Japanese Pharmacopoeia requirements for TOC analysis. This standard set contains: (2) 40-mL glass vial standards, (1) Reagent water, and (1) 500-µg C/L as SDBS standard. Sievers 900 Portable TOC Analyzer AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 10

12 Sievers 900 Series (continued) TOC Calibration Sets Multi-point Calibration Set (40-mL vials) CSTD Multi-point Calibration Standards Set, 40-mL vials Set includes: (1) Calibration Blank, (5) TOC Calibration Standards (1, 5, 10, 25, 50 mg C/L TOC as KHP), and (5) IC Calibration Standards (1, 5, 10, 25, 50 mg C/L IC as Na 2 CO 3 ). Single-point Calibration Standards Sets (40-mL vials) CSTD Single-point Calibration Standards Set, 1-mg/L Set includes: (1) Calibration Blank, (1) 1-mg C/L TOC Calibration Standard (as KHP), and (1) 1-mg C/L IC Standard (as Na 2 CO 3 ). CSTD CSTD CSTD CSTD Single-point Calibration and Verification Set, 1-mg/L Set includes: (1) TOC Calibration Set at 1 mg C/L and (1) Verification Standards Set at 1 mg C/L. Calibration set includes: (1) Calibration Blank, (1) 1-mg C/L TOC Calibration Standard (as KHP), and (1) 1-mg C/L IC Standard (as Na 2 CO 3 ). Verification set includes: (1) Verification Blank, (1) 1-mg C/L TOC Verification Standard (as NIST sucrose), and (1) 1-mg C/L IC standard (as Na 2 CO 3 ). 900 Single-point Calibration and Verification Set, 5-mg/L Set includes: (1) TOC Calibration Set at 5 mg C/L and (1) Verification Standards Set at 5 mg C/L. Calibration set includes: (1) Calibration Blank, (1) 5-mg C/L TOC Calibration Standard (as KHP), and (1) 5-mg C/L IC Standard (as Na 2 CO 3 ). Verification set includes: (1) Verification Blank, (1) 5-mg C/L TOC Verification Standard (as NIST sucrose), and (1) 5-mg C/L IC standard (as Na 2 CO 3 ) mg/L Single-point Calibration and 500-μg/L Verification Set Set includes: (1) TOC Calibration Set at 1 mg C/L and (1) Verification Standards Set at 500-μg C/L. Calibration set includes: (1) Calibration Blank, (1) 1-mg C/L TOC Calibration Standard (as KHP), and (1) 1-mg C/L IC Standard (as Na 2 CO 3 ). Verification set includes: (1) Verification Blank, (1) 500-μg C/L TOC Verification Standard (as NIST sucrose), and (1) 500-μg C/L IC standard (as Na 2 CO 3 ). 900 Autoreagents Calibration and Verification Set Set includes: Autoreagents Calibration and Verification Standards Set for the Sievers 900 Series. Calibration includes: (1) TOC Calibration Blank, (1) 25-mg C/L TOC Calibration Standard (as KHP), (1) 25-mg C/L IC Calibration Standard (as Na 2 CO 3 ), and (1) 50-mg C/L TOC Challenge Standard (as Nicotinamide). Verification includes: (1) TOC Verification Blank, (1) 25-mg C/L TOC Verification Standard (as NIST sucrose), (1) 50-mg C/L TOC Verification Standard (as NIST sucrose), and (1) 50-mg C/L IC Verification Standard (as Na 2 CO 3 ). Turbo Standards Calibration Turbo Standards Sets (250-mL bottles) CSTD Turbo Calibration and Verification Set Set includes: (1) Turbo Calibration Set at 4-mg/L C and (1) Verification Standards Set at 4-mg C/L. Calibration set includes: (1) 4-mg C/L TOC Calibration Standard (as KHP), and (1) 4-mg C/L IC Standard (as Na 2 CO 3 ). Verification set includes: (1) 4-mg C/L TOC Verification Standard (as NIST sucrose), and (1) 4-mg C/L IC standard (as Na 2 CO 3 ). 11 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

13 SIEVERS CERTIFIED REFERENCE MATERIALS SIEVERS 900 SERIES TOC Verification Sets Verification Standards (40-mL vials) CSTD CSTD Single-point Verification Set, 500 µg/l Set includes: (1) Verification Blank, (1) 500-µg C/L TOC Verification Standard (as NIST Sucrose), and (1) 500-µg C/L IC Standard (as Na 2 CO 3 ). 900 Single-point Verification Set, 1 mg/l Set includes: (1) Verification Blank, (1) 1-mg C/L TOC Verification Standard (as NIST Sucrose), and (1) 1-mg C/L IC Standard (as Na 2 CO 3 ). TOC Validation Sets Validation Standards (40-mL vials) CSTD Accuracy/Precision Set Set includes: (1) Reagent Water Control and (1) 500-μg C as NIST Sucrose standard solution. CSTD Validation Set Only Set includes: (2) System Suitability Sets, (1) Linearity Set, (1) Precision and Accuracy Set, (1) Robustness Set, and (1) Specificity Set. (Note: Calibration and Verification sets must be ordered separately.) CSTD CSTD CSTD CSTD Validation Set with Calibration and Verification Set includes: (2) Single-point Calibration Sets at 1-mg C/L, (1) Single-point Verification Set at 500-µg C/L, (2) System Suitability Sets, (1) Linearity Set, (1) Accuracy and Precision Set, (1) Robustness Set, and (1) Specificity Set. Linearity Standards Set Set includes: (1) Reagent Water Blank and (1) each 250-µg C/L, 500-µg C/L, 750-µg C/L as USP Sucrose. Specificity Standards Set Set includes: (1) Reagent Water Blank, (1) 500-µg C/L as Methanol, (1) 500 µg C/L as Nicotinamide, and (1) 500-µg C/L as KHP. Robustness Standards Set Set includes: (1) Reagent Water Blank Rw, (1) Standard Solution - Rs (500-µg C/L as USP Sucrose), and (1) System Suitability Solution - Rss (500-µg C/L as USP 1,4-Benzoquinone). Rw, Rs, and Rss standards are acidified. Certified TOC Sample Vials are also available for Sievers and other instruments. See page 27 for more information. AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 12

14 Sievers 500 RL Series The Sievers 500 RL On-Line Total Organic Carbon (TOC) Analyzer is a reagentless analyzer designed to continuously monitor organics in ultrapure water for pharmaceutical, microelectronics, power, and semiconductor applications. Super Convenient Integrated Super ios With a Super ios you plug in the combined standards pack, start your protocol, and walk away. Running the standards procedure has been completely automated. The 500 RL with Super ios model offers standards unique to the Sievers product line. Our patented and convenient Super ios vial set cartridges are pre-loaded with Sievers Standards and configured for a variety of protocols, including system suitability. The Super ios automatically sequences through the various vials for a protocol unattended. The Sievers Super ios enables the confidence and reliability of lab-based system suitability testing in an on-line analyzer. Following are the most frequently used standards for the 500 RL Series. For the full list of standards, see pages When ordering kits, please use the applicable part number and quantity. Standards for the 500 RL with Super ios System Suitability and Compendial Standards (40-mL vials) Blanket Order Option In addition to a full range of individual standard sets, we offer annual blanket orders at a discount that you can customize to meet your specific needs and have shipped at your desired intervals. STD KIT5MS Annual Pharmaceutical Standards Kit for Monthly Testing Sievers 500 RL with Super ios 12 x CSTD (System Suitability Set) Shipped one per month. System Suitability Set includes: (1) Reagent Water Control (Rw), (1) Standard Solution (Rs), and (1) System Suitability Solution (Rss). These standards are packaged in a vial cartridge for use with the Sievers Super ios System. CSTD RL System Suitability Set Super ios Set Includes: (1) Reagent Water Blank - Rw, (1) Standard Solution - Rs (500-µg C/L as USP Sucrose), (1) Standard Solution - Rss (500 µg C/L as USP 1,4-Benzoquinone), and (1) Rinse Water Standard. Super ios standards are packaged in a vial set cartridge for use with the Sievers Super ios System. Japanese Pharmacopoeia Testing (30-mL vials) CSTD RL with Super ios JP Protocol Set (TOC) Standard set for the Sievers 500 RL TOC Analyzer with Super ios that meets the new Japanese Pharmacopoeia TOC requirements. Set includes: (2) 30-mL plastic vial standards, (1) reagent water blank, and (1) 500-µg C/L as SDBS standard. The set also includes: (1) empty glass vial for alignment. These standards are packaged in a vial set cartridge for use with the Sievers Super ios System. 13 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

15 SIEVERS CERTIFIED REFERENCE MATERIALS SIEVERS 500 SERIES TOC and Conductivity Calibration Sets Multi-point Calibration Set (40-mL vials) CSTD RL with Super ios Multi-point Calibration Set Multi-point Calibration Set A and B for the Sievers 500 RL TOC Analyzer with Super ios. Includes: (3) Calibration Blanks, (3) TOC Calibration Standards (500 µg C/L, 1.0 mg C/L, 1.5 mg C/L as KHP), and (1) 25-µS/cm Conductivity Standard (as HCl). These standards are packaged in a vial set cartridge for use with the Sievers Super ios System. Single Point Calibration Set (40-mL vials and 30-mL vials) CSTD CSTD CSTD RL with Super ios Single-point Calibration Set Single-point Calibration Set A for the Sievers 500 RL TOC Analyzer with Super ios. Includes: (2) Calibration Blanks, (1) 1.5-mg C/L TOC Calibration Standard (as KHP), and (1) 25-µS/cm Conductivity Standard (as HCl). These standards are packaged in a vial set cartridge for use with the Sievers Super ios System. Conductivity Standard Conductivity Standard for the Sievers 500 RL and CheckPoint Series. This standard consists of (1) 25 µs/cm as HCl solution in a 30-mL plastic vial. 500 RL with Super ios Single-point Calibration and Verification Set Single-point Calibration Set A and Verification Standards Set for the Sievers 500 RL TOC Analyzer with Super ios. Includes: (1) Single-point Calibration Set and (1) Accuracy, Precision, and Verification Set. These standards are packaged in a vial set cartridge for use with the Sievers Super ios System. Accuracy, Precision, and Verification Sets (40-mL Vials) CSTD CSTD RL with Super ios Accuracy, Precision, and Verification Set Accuracy, Precision and Verification Set for the Sievers 500 RL TOC Analyzer with Super ios. Includes: (1) Verification Blank, (1) 500-µg C/L TOC Verification Standard (as NIST Sucrose), and (1) 25-µS/cm Conductivity Standard (as HCl). These standards are packaged in a vial set cartridge for use with the Sievers Super ios System. 500 RL with Super ios Accuracy, Precision, and Verification Set (TOC Only) Accuracy, Precision, and Verification Set for the Sievers 500 RL TOC Analyzer with Super ios. Includes: (1) Verification Blank and (1) 500-µg C/L TOC Verification Standard (as NIST Sucrose) packaged in a vial set cartridge for use with the Sievers Super ios System. Not compatible with 500 RL instruments equipped with the conductivity option. Validation Sets (40-mL Vials) CSTD RL with Super ios Single-point Validation Set Validation Standards Set with Single-point Calibration Set A for the Sievers 500 RL TOC Analyzer with Super ios. Includes: (1) Single-point Calibration Set, (2) Accuracy, Precision, and Verification Sets, (1) System Suitability Set, (1) Linearity Set, (1) Robustness Set, and (1) Specificity Set. These standards are packaged in a vial set cartridge for use with the Sievers Super ios System. AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 14

16 Sievers 500 RL Series (continued) Validation Sets (continued) CSTD RL with Super ios Multi-point Validation Set Validation Standards Set with Multi-point Calibration Set A and B for the Sievers 500 RL TOC Analyzer with Super ios. Includes: (1) Multi-point Calibration Set, (2) Accuracy, Precision, and Verification Sets, (1) System Suitability Set, (1) Linearity Set, (1) Robustness Set, and (1) Specificity Set. These standards are packaged in a vial set cartridge for use with the Sievers Super ios System. CSTD CSTD CSTD RL with Super ios Linearity Set Linearity Set for the Sievers 500 RL TOC Analyzers with Super ios. Includes: (1) Reagent Water Blank and (1) each 250 µg C/L, 500 µg C/L, and 750 µg C/L as KHP. These standards are packaged in a vial set cartridge for use with the Sievers Super ios System. 500 RL with Super ios Specificity Set Specificity Set for the Sievers 500 RL TOC Analyzers with Super ios. Includes: (1) Reagent Water Blank, (1) 500 µg C/L as Methanol, (1) 500 µg C/L as Nicotinamide, and (1) 500 µg C/L as KHP. These standards are packaged in a vial set cartridge for use with the Sievers Super ios System. 500 RL with Super ios Robustness Set Robustness Standard Set for the Sievers 500 RL TOC Analyzer with Super ios. Includes: (1) Reagent Water Blank - Rw, (1) Standard Solution - Rs (500 µg C/L as USP Sucrose), (1) System Suitability Solution - Rss (500 µg C/L as USP 1,4 Benzoquinone), and (1) Flush Standard. Rw, Rs, and Rss standards are non-acidified and are packaged in 30-mL HDPE vials. The Flush Standard is non-acidified and packaged in a 40-mL glass vial. These standards are packaged in a vial set cartridge for use with the Sievers Super ios System. Standards for the 500 RL with Standard ios CSTD STD KIT5M CSTD CSTD CSTD CSTD CSTD CSTD CSTD CSTD CSTD CSTD RL System Suitability Set Standard ios Annual Pharmaceutical Standards Kit for Monthly Testing Standard ios 500 RL JP Protocol Standard Set Standard ios 500 RL Multi-point Calibration Set Standard ios 500 RL Single-point Calibration Set A Standard ios 500 RL Single-point Calibration and Verification Set Standard ios 500 RL Accuracy, Precision, and Verification Set Standard ios 500 RL Single-point Validation Set Standard ios 500 RL Multi-point Validation Set Standard ios 500 RL Linearity Set Standard ios 500 RL/900 Specificity Set Standard ios 500 RL Robustness Set Standard ios 15 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

17 SIEVERS CERTIFIED REFERENCE MATERIALS SIEVERS 5310 C SERIES Sievers 5310 C Series GE Analytical Instruments offers 40-mL sample vials suitable for environmental and drinking water monitoring at competitive market pricing. The Sievers 5310 C Laboratory, Portable, and On-Line TOC Analyzers were designed specifically for the municipal drinking water market for continuous monitoring of raw, finished, and plant process waters. The 5310 C has an analytical range of 4 parts-per-billion (ppb) to 50 parts-per-million (ppm) and uses SM 5310 C for USEPA compliance monitoring of raw and finished drinking water. The 5310 C provides unsurpassed ease of use, industry-best analytical performance, and a low cost of ownership for water quality analysis. Sievers 5310 C On-Line, Portable, and Laboratory TOC Analyzers AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 16

18 Sievers 5310 C Series (continued) Following are the most frequently used standards for the 5310 C Series. For the full list of standards, see pages When ordering kits, please use the applicable part number and quantity. TOC Calibration Sets (40-mL vials) CSTD Single-point Calibration Standards Set 1 mg/l Set includes: (1) Calibration Blank, (1) 1-mg C/L TOC Calibration Standard (as KHP), and (1) 1-mg C/L IC Standard (as Na 2 CO 3 ). CSTD CSTD CSTD Single-point Calibration Standards Set 10 mg/l Set Includes: (1) Calibration Blank, (1) 10-mg C/L TOC Calibration Standard (as KHP), and (1) 10-mg C/L IC Standard (as Na 2 CO 3 ). Multi-point Calibration Set Set Includes: (1) Calibration Blank, (5) TOC Calibration Standards (250 µg C/L, 1, 5, 25, 50 mg C/L TOC as KHP), and (5) IC Calibration Standards (1, 5, 10, 25, 50 mg C/L IC as Na 2 CO 3 ). Autoreagents Calibration and Verification Set Set includes: Autoreagents Calibration and Verification Standards Set. Calibration includes: (1) TOC Calibration Blank, (1) 25-mg C/L TOC Calibration Standard (as KHP), (1) 25-mg C/L IC Calibration Standard (as Na 2 CO 3 ), and (1) 50-mg C/L TOC Challenge Standard (as Nicotinamide). Verification includes: (1) TOC Verification Blank, (1) 25-mg C/L TOC Verification Standard (as NIST sucrose), (1) 50-mg C/L TOC Verification Standard (as NIST sucrose), and (1) 50-mg C/L IC Verification Standard (as Na 2 CO 3 ). Verification Standards Set (40-mL vials) CSTD CSTD CSTD Municipal TOC Verification Set Municipal TOC Standards Set for the Sievers 5310 C Analyzers equipped with firmware versions 1.40 or greater. Set Includes: (1) 1-mg C/L, (1) 5-mg C/L, and (1) 10-mg C/L as KHP standard. Single-point Verification Set 10 mg/l Includes: (1) Verification Blank, (1) 10-mg C/L TOC Verification Standard (as NIST Sucrose), and (1) 10-mg C/L IC Standard (as Na 2 CO 3 ). Single-point Verification Set 2 mg/l Includes: (1) Verification Blank, (1) 2-mg C/L TOC Verification Standard (as NIST Sucrose), and (1) 2-mg C/L IC Standard (as Na 2 CO 3 ). 17 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

19 SIEVERS CERTIFIED REFERENCE MATERIALS CHECKPOINT ON-LINE / PORTABLE CheckPoint Pharma and CheckPoint e On-Line/Portable TOC Sensors The affordable CheckPoint Pharma and CheckPoint e On-Line/Portable Total Organic Carbon (TOC) Sensors provide unsurpassed flexibility in measuring low-level total organic carbon (TOC) online for microelectronics, pharmaceutical, and power applications. They can be used online for continuous monitoring or hand-carried to any point in a water system for rapid diagnostic sampling and troubleshooting. CheckPoint/CheckPoint e is the first and only battery-powered TOC measuring device. Following are the most frequently used standards for the CheckPoint. For the full list of standards, see pages When ordering, please use the applicable part number and quantity. CheckPoint Portable/On-Line TOC Sensor System Suitability Standards (30-mL plastic vials) CSTD System Suitability Set Set includes: (1) Rw Reagent Water Control, (1) Rs Standard Solution, and (1) Rss System Suitability Solution. TOC and Conductivity Calibration Standards (30-mL plastic vials) CSTD CSTD TOC Calibration Set Set includes: (2) Calibration Blanks and (1) 500 µg C/L as NIST sucrose. Conductivity Standard Set includes: Conductivity Standard for the Sievers 500 RL and CheckPoint Series. This standard consists of a 25-µS/cm as HCl solution in a 30-mL plastic vial. Performance Qualification Standards (30-mL plastic vials) CSTD TOC Linearity Set Set includes: (1) Linearity Blank and (1) each of 250 µg C/L, 375 μg C/L, and 500 μg C/L as NIST sucrose. AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 18

20 InnovOx Laboratory and On-Line TOC Analyzers The Sievers InnovOx Laboratory and On-Line Total Organic Carbon (TOC) Analyzers represent a true breakthrough in high TOC measurement technology and reliability. The InnovOx (short for innovative oxidation) can consecutively handle thousands of common as well as difficult samples such as brine and cellulose with unprecedented system uptime. The InnovOx offers unparalleled oxidation robustness, a dynamic linear working range of 0.5 to 50,000 ppm, and calibration curve stability for TOC analysis of process, environmental, and wastewater samples. Following are the most frequently used standards for the InnovOx. For the full list of standards, see pages When ordering, please use the applicable part number and quantity. InnovOx On-Line and Laboratory TOC Analyzers TOC Calibration Standards (250-mL bottles) CSTD CSTD CSTD CSTD CSTD Calibration 100 mg/l Set includes: (1) 250-mL bottle containing 100 mg C/L as KHP. Calibration 1,000 mg/l Set includes: (1) 250-mL bottle containing 1,000 mg C/L as KHP. Calibration 5,000 mg/l Set includes: (1) 250-mL bottle containing 5,000 mg C/L as KHP. Calibration 20,000 mg/l Set includes: (1) 250-mL bottle containing 20,000 mg C/L as KHP. Calibration Reagent Water Set includes: (1) 250-mL bottle containing Reagent Water (<0.1 mg C/L at preparation). TOC Calibration and Verification Standards (250-mL bottles) CSTD CSTD Calibration and Verification Kit 0 to 1,000-ppm range Set includes: 250-mL bottles with the following standards: Calibration Reagent Water, 1-mg C/L KHP, 10-mg C/L KHP, 25-mg C/L KHP, 100-mg C/L KHP, 1,000-mg C/L KHP. Verification 50-mg C/L Sucrose, 500-mg C/L Sucrose. Calibration and Verification 50,000 mg/l Set includes: (1) 250-mL bottle containing 50,000-mg C/L Sucrose. 19 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

21 SIEVERS CERTIFIED REFERENCE MATERIALS 860 LABORATORY Sievers 860 Laboratory TOC Analyzer The Sievers 860 Laboratory TOC Analyzer was developed for general pharmaceutical monitoring of Purified Water (PW) and Water for Injection (WFI). Based on the Sievers 900 Laboratory TOC Analyzer, the 860 Analyzer combines high-quality performance with affordability. It simplifies your day-to-day water testing routines, while giving you confidence in your monitoring results for regulatory compliance. The new Sievers RT12 Autosampler was designed for use with the Sievers 860. Following are the most frequently used standards for the Sievers 860. For the full list of standards, see pages When ordering, please use the applicable part number and quantity. Sievers 860 Laboratory TOC Analyzer System Suitability and Compendial Standards- (40 ml vials) CSTD System Suitability Verification Set Set Includes (1) Reagent Water Blank - Rw, (1) Standard Solution - Rs (500 µg C/L as USP Sucrose), (1) Standard Solution - Rss (500 µg C/L as USP 1,4-Benzoquinone), and (1) Rinse Water Standard. TOC Calibration Set - Single Point Calibration Set - (40 ml vials) CSTD Single Point Cal Set A (TOC Only) Single-point calibration set A. Includes (2) Calibration Blanks, (1) 1.5 mg C/L TOC Calibration Standard (as KHP). Accuracy, Precision, and Verification Sets CSTD Accuracy, Precision, and Verification Set (TOC Only) Accuracy, Precision and Verification set includes (1) Verification Blank and (1) 500 µg C/L TOC Verification Standard (as NIST Sucrose). Validation Sets To complete the validation protocol for the Model 860 after calibration three standards sets are required. CSTD CSTD CSTD Accuracy, Precision, and Verification Set (TOC Only) Accuracy, Precision and Verification set includes (1) Verification Blank and (1) 500 µg C/L TOC Verification Standard (as NIST Sucrose). System Suitability Verification Set Set Includes (1) Reagent Water Blank - Rw, (1) Standard Solution - Rs (500 µg C/L as USP Sucrose), (1) Standard Solution - Rss (500 µg C/L as USP 1,4-Benzoquinone), and (1) Rinse Water Standard. Linearity Set Linearity set includes, (1) 250 µg C/L, (1) 500 µg C/L (1) 750 µg C/L (as KHP) and (1) Linearity Blank. AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 20

22 SIEVERS CERTIFIED REFERENCE MATERIALS STANDARDS FOR NON-SIEVERS BRANDS The Convenience of Ready-made Standards Producing standards in-house that comply with regulations and quality systems can be a challenge. Organizations must consider and control many variables, such as: Skilled, trained, and consistent performance of technicians Standard Operating Procedure (SOP) adherence and development Validated and wellmaintained equipment Purity of reagent water Purity of raw material Cleaning and maintaining dedicated glassware Cleanliness of vials Documentation development and maintenance for NIST traceability, GLPs, and/or cgmps Many organizations have eliminated these variables and the costs, time, and complexity associated with in-house standards production by using Sievers Certified Reference Materials. They benefit from having reliable, ready-to-use standards at hand as needed, eliminating potential production delays and throughput reductions. Standards for Non-Sievers Brand TOC Instruments Sievers Standards are also compatible with most other laboratory-based TOC analyzers, such as: Shimadzu OI Analytical Skalar Teledyne-Tekmar For more information, please contact us at geai@ge.com, or see page 8 for other options. Custom Reference Materials for all TOC Instruments If you need standards that are not listed, please contact us. We can produce any TOC reference material you may need. After reviewing your requirements, we can typically turn around a custom order within 48 hours. To fulfill your custom standard set request, please provide the following information: Source material (USP/NIST, Sucrose, KHP, etc.) and desired concentration Instrument make/model for which the standard will be used Container typically 40-mL glass vials Estimated number of sets required Please send your request to orders@geinstruments.com, or see page 8 for other contact options. 21 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

23 TOC Sample Vials, Containers, and Cleaning Validation Kits Sievers Certified (<10 ppb) TOC Vials Sievers Certified (<10 ppb) TOC Vials are designed for use in critical pharmaceutical applications such as USP and EP Water testing as well as municipal water testing. Our certification to below 10 ppb TOC gives you confidence in the quality of your TOC measurements. In addition, they are: scrupulously cleaned in an ISO 9001 environment using a validated, automated process. manufactured by the global leader in TOC measurement technology and TOC standards. economical, with added savings on volume orders. reliable, with guaranteed performance. AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 22

24 SIEVERS CERTIFIED REFERENCE MATERIALS TOC SAMPLE VIALS, CONTAINERS AND CLEANING VALIDATION KITS TOC Sample Vials, Containers, and Cleaning Validation Kits Sievers Certified TOC Vials are compatible with most TOC analyzer brands, including Sievers, Shimadzu, OI Analytical, Teledyne-Tekmar, and Skalar. CHMI CHMI Certified TOC Vials, 40-mL, 72 per case Pre-cleaned and certified (<10 ppb) 40-mL glass vials with caps and Teflon-lined septa, 72 per case. These vials are the right choice for strict regulatory compliance testing. Pre-cleaned 17-mL Glass Vials with Caps and Septa, 200 per case Pre-cleaned 17-mL glass vials with caps and Teflon-lined septa, 200 per case. Certified (<10 ppb) TOC. Vial dimensions: 18 mm x 100 mm. GE TOC Sample Vials For environmental, municipal, and process applications, GE Analytical Instruments offers pre-cleaned 40-mL TOC sample vials. These vials are cleaned of organic residues with our advanced automated process in an ISO 9001 environment to ensure the quality of your TOC measurements. GE Analytical Instruments guarantees the performance of these vials. CHMI mL Sample Vials, 72 per case 40-mL glass vials with Teflon-lined septa, 72 per case. These are non-certified sample vials suitable for general process monitoring. They are guaranteed to be (<100 ppb) TOC. Additional Sample Containers CHMI CHMI CHMI HMI Pre-cleaned 60-mL glass vials with caps and septa, 72 per case. These Volatile Organic Analysis (VOA) vials are certified to meet EPA requirements. Vial dimensions: 26.5 mm x mm. Teflon-lined septa thickness: (3.2 mm). 35-mL Polypropylene Test Tubes for general sampling. These uncleaned, disposable containers have a round bottom with an open top. The test tubes are autoclavable. Tube dimensions: 20 mm x 150 mm. 30-mL Polysulfone Vials, 10 vials per pack. (1) pack containing 10 pre-cleaned 30-mL Polysulfone vials. Caps and septa must be ordered separately as HMI Pre-cleaned Septa and Cap Bonded. (1) pack containing 10 pre-cleaned 30-mL Polysulfone vials. TOC Cleaning Validation Kits Sievers TOC Cleaning Validation Kits feature low TOC background sampling swabs. Each kit includes (72) 40-mL Sievers Certified TOC Vials and (80) low-toc Alpha Sampling Swabs. Alpha Sampling Swabs are manufactured and certified by the worldwide leader in critical cleaning products to assure extremely low-background TOC levels. CAPK Cleaning Validation Kit contains (72) Sievers Certified TOC Vials (<10 ppb TOC) and (80) Certified Sampling Swabs (<50 ppb TOC). 23 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

25 Consumables, Reagents, and Replacement Parts GE Analytical Instruments manufactures consumable parts and reagents (acid and oxidizer) for use with TOC instrumentation. Our parts and reagents are designed and built to exact specifications for GE Analytical Instruments analyzers and sensors. To manufacture the purest reagent for TOC measurement and prevent any contribution of TOC, we use ultrapure water from our proprietary water system. We also manage raw material purity through rigorous testing and control. Lot records, TOC background testing, and quality controls are in place to limit contamination. Each reagent comes with a Certificate of Analysis. AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 24

26 SIEVERS CERTIFIED REFERENCE MATERIALS CONSUMABLES, REAGENTS, AND REPLACEMENT PARTS 900 SERIES, 500 SERIES Consumables, Reagents, and Replacement Parts Following are the most frequently used consumables, reagents, and replacement parts. For the full list, please see page 29. When ordering kits, please use the applicable part number and quantity. 900 and 5310 C Series C900 MAINT CAPF CAPF CAPF CARK CAPK CATU CPMK CAPK CAPK month 900 and 5310 C Series Consumable Kit 12-month Consumables Kit for the Sievers 900 and 5310 C Series. Includes: (4) Persulfate Reagents (150 ml ea.), (2) Acid Reagents, (2) UV Lamps, (1) Pump Tubing, and (1) Ion Exchange Resin Bed. Items delivered and billed on a quarterly schedule. Acid Reagent Cartridge 300-mL Acid Reagent Cartridge for the Sievers 900 and 5310 C Series. Replacement is recommended after 6 months. Low-capacity Oxidizer Cartridge Low-capacity, 150-mL, Oxidizer Reagent Cartridge for the Sievers 900, 5310 C, and 800 Series. Replace after 3 months of use. High-capacity Oxidizer Cartridge High-capacity, 300-mL, Oxidizer Reagent Cartridge for the Sievers 900 and 5310 C Series. Replace after 3 months. UV Lamp, Multiple Instruments UV Lamp for the Sievers 900 and 5310 C Series. Lamp lifetime is 6 months of operation. Resin Bed Replacement Replacement Resin Cartridge for the Sievers 900 and 5310 C Series Analyzers. Sample Pump Tubing Sample Pump Tubing for the Sievers 900 and 5310 C Series Analyzers. ICR Preventive Maintenance Kit Annual Preventive Maintenance Kit for the 900 Inorganic Carbon Remover (ICR). Kit includes the degassing module, chemical trap, diaphragm replacement kit, and a 25-ppm C as sodium carbonate standard to verify operation of the ICR after maintenance. Standalone Degasser Replacement Degassing Module for the Inorganic Carbon Remover (ICR) used with the 900 Series and 5310 C Laboratory C On-Line ICR Degassing Replacement Degassing Module for the Inorganic Carbon Remover (ICR) used with the 5310 C On-Line. 500 RL and 860 Series CARK UV Lamp, Multiple Instruments UV Lamp for the Sievers PPT, 900 Series, 500 RL Series, 860 and CheckPoint. Average Lamp life is 6 months of operation. 25 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

27 SIEVERS CERTIFIED REFERENCE MATERIALS CONSUMABLES, REAGENTS, AND REPLACEMENT PARTS 5310 C SERIES, INNOVOX, CHECKPOINT 500 RL and 860 Series CAPK CAPK DI Reservoir/Resin Replacement DI Reservoir/Resin Replacement part for 500 RL and 860 Analyzers. This part is a consumable that needs to be replaced every 2 years. Sample Pump For Sievers 500 RL and 860 series analyzer sample pump head. InnovOx Series CAPK CAPK Reagent, Na 2 S 2 O 8, 6-pack Kit contains six pouches of dry sodium persulfate reagent. Each pouch makes 2L of 30% sodium persulfate solution. Reagent, Na 2 S 2 O 8, Single-pack Kit contains one pouch of dry sodium persulfate reagent. The pouch makes 2L of 30% sodium persulfate solution. This kit is provided with new instrument shipments. CSCH M Hydrochloric Acid 2.5L 3M HCl acid container for the InnovOx Analyzer. This 2.5L reagent container can only be purchased and shipped in Europe, the Middle East, and Africa. CSCH CAPK CAPK Hydrochloric Acid, 3M, 500 ml 0.5 liters of 3M HCl acid reagent for the InnovOx Analyzer. This container is drop shipped to the customer s location within North America only. Kit, Air Purifier, InnovOx Replacement Air Filter Cartridge for the optional air filter system. Kit, Sample Pump, InnovOx Replacement Peristaltic Pump for the InnovOx Analyzer. CheckPoint and CheckPoint e CARK CAPK UV Lamp, Multiple Instruments UV Lamp for the CheckPoint. Average lamp life is 6 months of operation. CheckPoint Consumables Kit (2) UV Lamps and (2) Pump Heads. CAPK Pump Head Kit Sample Pump Head Assembly Kit for CheckPoint. AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 26

28 Product Index Sievers Certified Reference Materials Model Model CSTD Standard Solution Rs 400 CSTD TOC Calibration Standard 400 CSTD Reagent Water Control Rw 400 CSTD TOC Calibration Blank 400 CSTD TOC Calibration Standards Set 400 CSTD Linearity Standards Set 400 CSTD DI Accuracy and Precision Set 400 CSTD Equilibrated Water 400 CSTD DI Validation Set, CDI Firmware 400 CSTD Calibration Standards Set 400 STD System Suitability Solution 400 STD Validation Set, CUE 400 STD KIT4M Annual Pharma Standards Kit, monthly 400 STD KIT4Q Annual Pharma Standards Kit, quarterly 400 STD KIT4W Annual Pharma Standards Kit, weekly 400 CSTD TOC Calibration Standard 800 CSTD IC Calibration Standard 800 CSTD Calibration Blank 800 CSTD Standard Solution Rs 800/900 CSTD TOC Standard 800 CSTD Reagent Water Control Rw 800/900 CSTD TOC Standard Blank 800 CSTD System Suit Solution Rss 800/900 CSTD Cal. Standards Set, Grab Mode 800 CSTD Cal. Standards Set, Autosampler 800 CSTD System Suitability Set, AS 800 CSTD TOC Standard Set 800 CSTD Validation Standards Set, Grab 800 CSTD Validation Standards Set, AS 800 CSTD RL Single-point Calibration Set A 500 RL CSTD RL Accuracy/Precision/Verification Set 500 RL CSTD RL/860 System Suitability Set 500 RL/860 CSTD RL/860 Single-point Cal. Set A (TOC Only) 500 RL/860 CSTD RL/860 Linearity Set 500 RL/860 CSTD RL/860 Acc/Prec/Ver Set (TOC Only) 500 RL/860 CSTD RL Robustness Set 500 RL CSTD RL JP Protocol Standard Set (TOC) 500 RL CSTD RL Super ios Single-point Cal. Set A 500 RL CSTD RL Super ios Acc/Prec/Ver Set 500 RL CSTD RL Super ios System Suitability 500 RL CSTD RL Super ios Single-pt. Cal. A (TOC Only) 500 RL CSTD RL Super ios Linearity Set 500 RL CSTD RL Super ios Acc/Prec/Ver (TOC Only) 500 RL CSTD RL Super ios Robustness Set 500 RL CSTD RL Super ios Specificity Set 500 RL CSTD RL Super ios Single-pt. Cal. A/Ver 500 RL CSTD RL Super ios Single-pt. Validation 500 RL CSTD RL Super ios Multi-pt. Cal. Set A&B 500 RL CSTD RL Super ios Multi-pt. Validation 500 RL CSTD RL Super ios Multi-pt. Cal. A&B/Ver 500 RL CSTD RL SiOS Single-pt. Cal/Ver (TOC Only) 500 RL CSTD RL SiOS Multi-pt. Cal. Set (TOC Only) 500 RL CSTD RL SiOS Multi-pt. Cal/Ver (TOC Only) 500 RL CSTD RL Super ios Rinse Vial Set 500 RL CSTD RL Super ios JP Protocol Set (TOC) 500 RL CSTD RL Single-pt. Cal/Ver Set 500 RL CSTD RL Single-pt. Validation Set 500 RL CSTD RL Multi-pt. Calibration Set A & B 500 RL CSTD RL Multi-pt. Validation Set 500 RL CSTD RL Multi-pt. Cal. A&B/Ver Set 500 RL CSTD RL Single-pt. Cal/Ver Set TOC Only 500 RL CSTD RL Multi-pt. Cal. Set A&B (TOC Only) 500 RL CSTD RL Multi-pt. Cal/Ver Set (TOC Only) 500 RL MIS RL Custom Standards Kit 500 RL STD KIT5M Annual Pharma Stds. Kit, monthly 500 RL STD KIT5MS Annual Pharma Stds. Kit, monthly SiOS 500 RL STD KIT5Q Annual Pharma Stds. Kit, quarterly 500 RL STD KIT5QS Annual Pharma Stds. Kit, quarterly SiOS 500 RL STD KIT5W Annual Pharma Stds. Kit, weekly 500 RL STD KIT5WS Annual Pharma Stds. Kit, weekly SiOS 500 RL CSTD Specificity Set 500 RL/900 CSTD Multi-pt. Calibration Standards Set 900 CSTD Single-pt. Calibration Standards Set 900 CSTD Single-pt. Calibration Set, 5 mg/l 900 CSTD Single-pt. Calibration Set, 10 mg/l 900 CSTD Single-pt. Calibration Set, 25 mg/l 900 CSTD Single-pt. Calibration Set, 50 mg/l 900 CSTD Single-pt. Verification Set, 500 µg/l 900 CSTD Single-pt. Verification Set, 1 mg/l 900 CSTD Single-pt. Verification Set, 2 mg/l 900 CSTD Single-pt. Verification Set, 5 mg/l 900 CSTD Single-pt. Verification Set, 10 mg/l TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

29 Product Index Sievers Certified Reference Materials Model Model CSTD Single-pt. Verification Set, 25 mg/l 900 CSTD Single-pt. Verification Set, 50 mg/l 900 CSTD Turbo Calibration Set, 4 mg/l 900 CSTD Turbo Verification Set, 4 mg/l 900 CSTD Single-pt. Cal/Ver Set, 1 mg/l 900 CSTD Single-pt. Cal/Ver Set, 5 mg/l 900 CSTD Single-pt. Cal/Ver Set, 10 mg/l 900 CSTD Single-pt. Cal/Ver Set, 25 mg/l 900 CSTD Single-pt. Cal/Ver Set, 50 mg/l 900 CSTD Turbo Cal/Ver Set, 4 mg/l 900 CSTD Validation Set Only 900 CSTD Validation Set with Cal/Ver 900 CSTD mg/l Cal, 500 µg/l Ver 900 CSTD Autoreagents Cal/Ver 900 CSTD Autoreagents Verification Set 900 CSTD Autoreagents Calibration Set 900 CSTD Robustness Set 900 CSTD JP Protocol Standard Set 900 CSTD System Suitability Set 800/900 CSTD Linearity Standard Set 800/900 CSTD Accuracy and Precision Set 800/900 STD KIT8D Annual Pharma Standards Kit, daily 800/900 STD KIT8M Annual Pharmal Standards Kit, monthly 800/900 STD KIT8Q Annual Pharma Stds. Kit, quarterly 800/900 STD KIT8W Annual Pharma Standards Kit, weekly 800/900 CSTD Municipal TOC Verification Set (V1.40+) 5310 C CSTD C MP Calibration Set (V1.40 or later) 5310 C CSTD CheckPoint System Suitability Set 400/CheckPoint CSTD CheckPoint TOC Linearity Set CheckPoint CSTD CheckPoint TOC Calibration Set CheckPoint CSTD InnovOx 0-1,000 ppm Cal. and Ver. InnovOx CSTD InnovOx TOC Service Kit InnovOx CSTD InnovOx Reagent Water InnovOx CSTD InnovOx TOC Calibration, 100 mg/l InnovOx CSTD InnovOx TOC Calibration, 1,000 mg/l InnovOx CSTD InnovOx TOC Calibration, 5,000 mg/l InnovOx CSTD InnovOx TOC Calibration, 20,000 mg/l InnovOx CSTD InnovOx TOC Cal/Ver, 50,000 mg/l InnovOx CSTD /500/CheckPoint Conductivity Std. Multiple STD TOC Custom Standards Multiple CSTD PPT Conductivity Standard, 100 µs/cm PPT CSTD PPT, Cal. Standard, 400-mg/L Sucrose PPT CSTD PPT, Verification Standard, 4 mg/l PPT STD PPT, 4-mg/L TOC Challenge PPT STD PPT 4-mg/L TOX Challenge PPT, TOC Sample Vials, Containers, Cleaning Validation Kits Model HMI Pre-cleaned Septa 400 HMI Pre-cleaned, 40-m/L Vials, 9-pack 400 CHMI Polysulfone Vials, 10-pack 400 CHMI Pre-cleaned, 17-mL Glass Vials with Caps 900 CAPK Cleaning Validation Kit 900 CHMI Pre-cleaned, 60-mL Glass Vials InnovOx CHMI Polypropylene Test Tubes, 35 ml InnovOx CHMI mL Sample Vials, 72 per case Multiple CHMI Certified TOC Vials, 40 ml, 72 per case Multiple AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com 28

30 Product Index Consumables, Reagents, and Replacement Parts Model Model CATU C Pump Tubing 400 CATU Pump Tubing, 400/2244OL 400 CHFL Fan Filter, 5-pack 400 PMK Maintenance Kit, 400, Black Pump 400 PMK Maintenance Kit, 400ES, Silver Pump 400 SOL Vial, HCl Rinse Solution 400 CACT Chemical Trap IC Remover 800 CAPF Acid Reservoir for 800/2244AP 800 CAQC Degassing Module 800 CARE UV Lamp 800/400 CASM G Needle Assembly 800 CATU Pump Tubing 800 CHMI Septa, 40 ml, 144-pack 800 CHMI A Autosampler Shuttle 800 CPMK Diaphragm Pump Rebuild Kit 800 CPMK ICR Preventive Maintenance Kit 800 HMI Precleaned Septa and Cap Bonded 800 HMI mm Tube Racks, 19 per set 800 TOC MAINT 12-month 800 Consumables Kit 800 CATU Pump Tubing PPT C900 MAINT 12-month 900 Series Consumable Kit 900/5310 C CACT ICR Chemical Trap 900/5310 C CAPF Oxidizer Cartridge, 150 ml 800/900/5310 C CAPF Oxidizer Cartridge, Hi Capacity, 300 ml 900/5310 C CAPF Acid Cartridge 900/5310 C CAPK Standalone Degasser Replacement 900/5310 C CAPK C OL, ICR Degasser Replacement 5310 C CAPK Kit, Resin Bed Replacement 900/5310 C CAPK Ozone Destruct Kit for 900 Portable 900 CAPK Ozone Destruct Kit for 900 On-line 900 CAPK AS Needle Assembly Kit 900/5310 C CAPK On-line Municipal Water Add-On 5310 C CAQC Degassing Module 800/900/5310 C CARK UV Lamp, Multiple Instruments 900/500 /860/ CkPt CASM Multi-holed Sipper Tube Assembly 900/5310 C CATU Sample Pump Tubing 900/5310 C CHFL Capsule Filter, High Capacity, 40 micron 900/5310 C CHFL micron Cartridge Filter 900/5310 C CHFL micron Bag Filter, PPE 900/5310 C CHTF Disc Filter 900 CPMK ICR Preventive Maintenance Kit 900 CPMK ICR Preventive Maintenance Kit 900/5310 C CPMK ICR Reclaim Maintenance Kit 900 ASM Boron Reagent Refill Boron ASM Boron Pump Tubing Boron ASM Boron Set of Columns Boron ASM Boron Zero Column Boron ASM Boron Reagent Column Boron HMI mm Filter Media, 5-pack Boron HTF Boron Inline 15-micron Filter Boron HTF Boron 15-micron SS Inline Filter Media Boron CAPK Sample Pump Heads 500 RL/860 CAPK DI Reservoir/Resin Replacement 500 RL/860 CAPK Kit, Pump Head Assembly CheckPoint CAPK Consumables Kit CheckPoint CAPK Filter Element Kit CheckPoint CEMI Spare Battery CheckPoint CAPK InnovOx, Peristaltic Pump Assembly InnovOx CAPK InnovOx, Oxidizer Reagent, 6-pack InnovOx CAPK InnovOx, Oxidizer Reagent, Single InnovOx CAPK InnovOx, Pinch Tubing Kit InnovOx CAPK InnovOx, Reactor Seal Kit InnovOx CAPK InnovOx, Air Filter Cartridge InnovOx CASM InnovOx, Autosampler Needle Kit InnovOx CATU InnovOx, Reagent Line, One Fitting InnovOx CATU InnovOx, Reagent Line, Two Fittings InnovOx CATU InnovOx, Autosampler Tubing Kit InnovOx CHFL InnovOx, NDIR Filter InnovOx CHMI InnovOx, 20-Mesh Coarse Screen InnovOx CHMI InnovOx, 100-Mesh Fine Screen Disc InnovOx CSCH InnovOx, 0.5L Acid (N. America Only) InnovOx CSCH InnovOx, 2.5L Acid (Europe Only) InnovOx CARK Pump Diaphram Maintanance Kit Multiple CHMI Epson Thermal Printer Paper Multiple CHTF In-Line SS Filter, 60 micron Multiple CHTF Replacement Filter, 60 micron Multiple 29 TO ORDER: ASIA PACIFIC E: geai.asia@ge.com geai.china@ge.com geai.india@ge.com geai.japan@ge.com

31 SIEVERS CERTIFIED REFERENCE MATERIALS AND CONSUMABLES HOW TO ORDER How To Order The Americas Tel: or Fax: Send purchase orders to: Send general inquiries to: Web Store: Office Hours: Monday through Friday, 10:00 am - 7:00 pm (EST) Europe, Middle East and Africa U.K. (European Headquarters) Tel: +44 (0) Fax: +44 (0) geai.europe@ge.com Austria Tel: Fax: Germany Tel: Fax: Ireland Tel: or Fax: or France Tel: Numéro vert Fax: Asia Pacific All Countries geai.asia@ge.com China Tel: +(8621) Fax: +(8621) geai.china@ge.com India Tel: geai.india@ge.com Japan geai.japan@ge.com Credit Cards We accept Visa, MasterCard, and American Express. Rapid Shipping Same day shipping is available for most products in North America and Europe. GE Analytical Instruments can deliver your product throughout the world from one of our standards and consumables manufacturing facilities in the US, UK, China, and India. AMERICAS T: E: orders@geinstruments.com EUROPE, MIDDLE EAST, AFRICA T: +44 (0) E: geai.europe@ge.com

imagination at work Sievers Certified Reference Materials and Consumables Catalog GE Power & Water Water & Process Technologies

imagination at work Sievers Certified Reference Materials and Consumables Catalog GE Power & Water Water & Process Technologies GE Power & Water Water & Process Technologies Analytical Instruments Sievers Certified Reference Materials and Consumables Catalog imagination at work imagination at work www.geinstruments.com Sievers

More information

Sievers M9 TOC Analyzers

Sievers M9 TOC Analyzers www.sieversinstruments.com Water Technologies & Solutions Sievers M9 TOC Analyzers * m-power your team to be compliant and efficient dependability and flexibility: Sievers legacy As the world s leading

More information

Sievers 500 RL On-Line TOC Analyzer

Sievers 500 RL On-Line TOC Analyzer GE Water & Process Technologies Analytical Instruments Sievers 500 RL On-Line TOC Analyzer Standard ios Model Super ios Model Overview The drive to improve quality and operating efficiencies demands analytical

More information

New! Sievers M9 TOC Analyzers

New! Sievers M9 TOC Analyzers Now with Sample Conductivity! New! Sievers M9 TOC Analyzers Reach the peak of productivity Tools that boost productivity are essential to managing your chaotic workday. The new Sievers* M9 Total Organic

More information

QbD1200 TOTAL ORGANIC CARBON ANALYZER RELIABLE MEASUREMENT MADE SIMPLE.

QbD1200 TOTAL ORGANIC CARBON ANALYZER RELIABLE MEASUREMENT MADE SIMPLE. QbD1200 TOTAL ORGANIC CARBON ANALYZER RELIABLE MEASUREMENT MADE SIMPLE. The NEW QbD1200 delivers the highest performance with unparalleled ease of operation and maintenance Reliable data Stop throwing

More information

Performance of the Sievers 500 RL On-Line TOC Analyzer

Performance of the Sievers 500 RL On-Line TOC Analyzer GE Water & Process Technologies Analytical Instruments Performance of the Sievers 500 RL On-Line TOC Analyzer imagination at work Page 2 of 10 Introduction To determine the performance characteristics

More information

Standard Operating Procedure Title: Operation and Calibration of Sievers 820 TOC Analyser

Standard Operating Procedure Title: Operation and Calibration of Sievers 820 TOC Analyser Table of Contents 1. 25 ppm IC as Sodium Carbonate - standard preparation procedure 2 2. 25 ppm TOC as KHP standard preparation procedure 3 3. Calibration Procedure 4 4. Performing Calibration - Prepare

More information

5000TOCi with ISM. Fast, Continuous and Reliable Total Organic Carbon Measurement

5000TOCi with ISM. Fast, Continuous and Reliable Total Organic Carbon Measurement 5000TOCi with ISM 5000TOCi Sensor Fast, continuous measurement Reliable operation Reagent and chemical free USP , , Ch P, EP 2.2.44, and JP compliant Compact sensor design ISM diagnostics Fast,

More information

Product Descriptions and Offerings

Product Descriptions and Offerings Product Descriptions and Offerings Teledyne Tekmar, is the leader in analytical instrumentation for the laboratory. The Volatile Organic Compound (VOC) products are world-renown and include systems for

More information

Custom processing services

Custom processing services Custom processing services Cleaning excellence for your critical environment The only thing in your container is what you add Save wasted resources dedicate your time to the manufacturing process, not

More information

Product Descriptions and Offerings

Product Descriptions and Offerings Product Descriptions and Offerings Teledyne Tekmar, is the leader in analytical instrumentation for the laboratory. The Volatile Organic Compound (VOC) products are world-renown and include systems for

More information

Application Note AN1501

Application Note AN1501 Application Note AN1501 Ultra-Trace Mercury Determination in Bottled Water, EPA Method 1631, Using the QuickTrace M-8000 CVAFS Introduction Mercury determination in water and foodstuffs is a crucial part

More information

Confidence in Compliance

Confidence in Compliance THORNTON Leading Pure Water Analytics Confidence in Compliance Pharmaceutical Water Compliance for Global Pharmacopeia Requirements Contents Page 1. Water Purity Standards 3 2. What is USP? 3 2.1 Conductivity

More information

Importance of TOC measurement in WFI in light of European Pharmacopoeia change

Importance of TOC measurement in WFI in light of European Pharmacopoeia change WITE PAPER Importance of TOC measurement in WFI in light of European Pharmacopoeia change Tony arrison, Applications Specialist Beckman Coulter, Inc. Abstract The new revision of the European Pharmacopoeia

More information

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement Method 8000 DR/4000 PROCEDURE Reactor Digestion Method* (0 to 150.0 mg/l COD) Scope and Application: For water, wastewater and seawater; digestion is required; USEPA Approved** for wastewater analyses.

More information

Critical Environment Products and Services

Critical Environment Products and Services Critical Environment Products and Services For over two decades, EP Scientific products and services have defined clean for environmental sampling containers and services. Our proprietary cleaning methods

More information

At Your ServIce. Microbiology Services. The life science business of Merck operates as MilliporeSigma in the U.S. and Canada.

At Your ServIce. Microbiology Services. The life science business of Merck operates as MilliporeSigma in the U.S. and Canada. At Your ServIce Microbiology Services The life science business of Merck operates as MilliporeSigma in the U.S. and Canada. Microbiology Services Optimize your QC lab workflow and ensure regulatory compliance

More information

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer Simplicity Accuracy Durability Lotix Automated High Temperature Combustion TOC Analyzer The Lotix TOC Combustion analyzer is designed to accurately measure carbon content in aqueous matrices down to the

More information

Optimize Your Process Operations by Improving Process Monitoring

Optimize Your Process Operations by Improving Process Monitoring Integral Process Ana Optimize Your Process Operations by Improving Process Monitoring All industrial processes have a common need reliable, accurate, and timely methods for analyzing process chemistry.

More information

Thermo Scientific HyClone WFI Quality Water. Ultra pure to meet today s rapid manufacturing advances

Thermo Scientific HyClone WFI Quality Water. Ultra pure to meet today s rapid manufacturing advances Thermo Scientific HyClone WFI Quality Water Ultra pure to meet today s rapid manufacturing advances What sets Thermo Scientific HyClone WFI Quality Water apart? Our cgmp ISO 9001 manufacturing facility,

More information

Lean Strategies for Laboratory Testing. Jenny Watson Global Pharmaceutical Applications Manager GE Analytical Instruments

Lean Strategies for Laboratory Testing. Jenny Watson Global Pharmaceutical Applications Manager GE Analytical Instruments Lean Strategies for Laboratory Testing Jenny Watson Global Pharmaceutical Applications Manager GE Analytical Instruments Agenda Operational Excellence & Lean Case Study The Balancing Act Time Quality Cost

More information

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive. 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive. 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity Silica Analyzer 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity Grab sample capability Low maintenance Automated Silica Measurement Dependable and Sensitive Silica Analyzer 2800S i

More information

Fast, Continuous and Reliable Total Organic Carbon Measurement

Fast, Continuous and Reliable Total Organic Carbon Measurement 5000TOCi Sensor Fast, continuous measurement Reliable operation Reagent and chemical free USP , , Ch P, EP 2.2.44, and JP compliant Compact sensor design ISM diagnostics Fast, Continuous and

More information

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD Method 8000 DR/4000 PROCEDURE Reactor Digestion Method* (0 to 40.0** mg/l COD) Scope and Application: For water, wastewater and seawater; digestion is required. The estimated detection limit for program

More information

Confidence in Compliance

Confidence in Compliance THORNTON Leading Pure Water Analytics Confidence in Compliance Pharmaceutical Water Compliance for Global Pharmacopeia Requirements Contents Page 1. Water Purity Standards 3 2. What Is USP? 3 2.1 Conductivity

More information

The Right Analytical Method for the Right Application: TOC Analysis for Cleaning Validation

The Right Analytical Method for the Right Application: TOC Analysis for Cleaning Validation GE Water & Process Technologies Analytical Instruments Paper The Right Analytical Method for the Right Application: TOC Analysis for Cleaning Validation Advances in technologies and mounting manufacturing

More information

TOC600 ANALYZER S TANDARD OPERATING P ROCEDURES

TOC600 ANALYZER S TANDARD OPERATING P ROCEDURES TOC600 ANALYZER S TANDARD OPERATING P ROCEDURES Hach Ultra Analytics 5600 Lindbergh Drive Loveland, Colorado 80538 U.S.A. Voice: 1 970 663-9760 1 800 373 0531 Fax: 1 970 663-9761 Support Hot Line: 1 877

More information

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive Silica Analyzer 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity Grab sample capability Low maintenance Automated Silica Measurement Dependable and Sensitive Silica Analyzer 2800S i

More information

Kjeldahl analysis with FOSS Kjeltec systems more clever than ever. Dedicated Analytical Solutions

Kjeldahl analysis with FOSS Kjeltec systems more clever than ever. Dedicated Analytical Solutions Kjeldahl analysis with FOSS Kjeltec systems more clever than ever Dedicated Analytical Solutions Your new Kjeltec More clever than ever! Based on the renowned accuracy, cost effectiveness and safety of

More information

Fusion UV/Persulfate TOC Analyzer

Fusion UV/Persulfate TOC Analyzer Fusion UV/Persulfate TOC Analyzer The Fusion Total Organic Carbon (TOC) Analyzer utilizes powerful Ultra Violet (UV) Persulfate oxidation allowing superior carbon liberation from even the most challenging

More information

Fusion UV/Persulfate TOC Analyzer

Fusion UV/Persulfate TOC Analyzer Fusion UV/Persulfate TOC Analyzer Unparalleled Results with the Fusion UV/Persulfate TOC Analyzer Description The Fusion Total Organic Carbon (TOC) Analyzer utilizes powerful Ultra Violet (UV) Persulfate

More information

Thermo Scientific Barnstead LabTower EDI water purification system

Thermo Scientific Barnstead LabTower EDI water purification system Thermo Scientific Barnstead LabTower EDI water purification system The Barnstead LabTower EDI is an integrated system combining purification with EDI technology and storage in one, as well as producing

More information

Excipients Facing Increased Scrutiny How to Use Secondary Reference Standards to Help Maintain Regulatory Compliance

Excipients Facing Increased Scrutiny How to Use Secondary Reference Standards to Help Maintain Regulatory Compliance Excipients Facing Increased Scrutiny How to Use Secondary Reference Standards to Help Maintain Regulatory Compliance by Tom Savage, NSF International Since 2008, when patient deaths were first linked to

More information

Spectroscopy Solutions for Pharmaceuticals:

Spectroscopy Solutions for Pharmaceuticals: Spectroscopy Solutions for Pharmaceuticals: Confidence in Compliance to USP Using the Agilent Cary 60 UV-Vis Spectrophotometer White Paper Introduction UV-Vis spectroscopy is one of the most commonly

More information

Bringing custom solutions and contract manufacturing to life

Bringing custom solutions and contract manufacturing to life GE Healthcare Bringing custom solutions and contract manufacturing to life Imagined. Delivered. Supported. Custom and bulk solutions Tailored to your precise specifications, our custom products deliver

More information

Purite Water Purification Systems

Purite Water Purification Systems SELECT WATER PURIFICATION Water Purification The Select range of high performance water purification systems offers a unique combination of reliability, quality and functionality for all laboratory applications.

More information

NPOC, VOC, TC-IC and TDN using Shimadzu TOC-V Protocols. Water Quality Analysis Laboratory at the University of New Hampshire

NPOC, VOC, TC-IC and TDN using Shimadzu TOC-V Protocols. Water Quality Analysis Laboratory at the University of New Hampshire NPOC, VOC, TC-IC and TDN using Shimadzu TOC-V Protocols Water Quality Analysis Laboratory at the University of New Hampshire Prepared by: Jeffrey Merriam Date of Last Revision: 10/26/2004 Signature of

More information

Validation of On-line Total Organic Carbon Analysers for Release Testing Using ICH Q2

Validation of On-line Total Organic Carbon Analysers for Release Testing Using ICH Q2 WITEPAPER Validation of On-line Total Organic arbon Analysers for Release Testing Using I Q2 Introduction As the pharmaceutical industry seeks to reduce the number and associated costs of quality control

More information

Monitoring THMs and TOC in High-Purity Process Water Systems

Monitoring THMs and TOC in High-Purity Process Water Systems World Leader in Total Organic Carbon Analysis Model A-1000/A-1000XP/Access 643 Total Organic Carbon Analysis Systems Monitoring THMs and TOC in High-Purity Process Water Systems Introduction Trihalomethanes

More information

QAM-I-113 Operation and Calibration of the Dissolved Oxygen Meter

QAM-I-113 Operation and Calibration of the Dissolved Oxygen Meter 1.0 Applicability and Purpose i. This procedure applies to the operation and calibration of the YSI Model 5100 dissolved oxygen meter or equivalent and associated probe. By performing the calibration procedure

More information

Online. Field Laboratory. Water Testing Product Sampler HFscientific.com. Visit our Web Site HFscientific.com. Visit Us at:

Online. Field Laboratory. Water Testing Product Sampler HFscientific.com. Visit our Web Site HFscientific.com. Visit Us at: Visit our Web Site HFscientific.com Water Quality Measurement Solutions Online Water Testing Product Sampler 2016 Field Laboratory 3170 Old Metro Parkway Ft. Myers, FL 33916 www.hfscientific.com toll free:

More information

Reference Standard Characterization. Steve Lane. General Manager, NSF Reference Standards.

Reference Standard Characterization. Steve Lane. General Manager, NSF Reference Standards. Reference Standard Characterization Steve Lane General Manager, NSF Reference Standards www.nsf-rs.org Regulatory Bodies will require that an Excipient: Be safe in the amount or dose used Meet applicable

More information

ESI SC-FAST Sample Introduction Solutions for PerkinElmer ICP-OES and ICP-MS Systems

ESI SC-FAST Sample Introduction Solutions for PerkinElmer ICP-OES and ICP-MS Systems PAPPLICATION R O D U C T NNOTE O T E ICP-OES and ICP-MS SC-FAST Benefits Increases sample throughput 2-3 times Minimizes sample uptake and rinse-out time Eliminates contact with peristaltic pump tubing

More information

Services. Premium. See inside to find out more!

Services. Premium. See inside to find out more! Premium Services Depyrogenation Sterilisation Barcoding & Tare Weighing Particulate Cleaning Surface Treatment Custom Packaging See inside to find out more! Allowing our customers to focus on their core

More information

Agilent 7693A Series Automatic Liquid Sampler Inject new performance into your gas chromatography. Our measure is your success.

Agilent 7693A Series Automatic Liquid Sampler Inject new performance into your gas chromatography. Our measure is your success. Agilent 7693A Series Automatic Liquid Sampler Inject new performance into your gas chromatography. Our measure is your success. products applications soft ware services Agilent 7693A Series Automatic Liquid

More information

1080 Total Organic Carbon Analyzer

1080 Total Organic Carbon Analyzer 1080 Total Organic Carbon Analyzer Easily Analyze Difficult to Oxidize Samples Total organic carbon (TOC) measurement is a well-established technique that provides valuable information about water quality

More information

ORDERING INFORMATION AFRICA AUSTRALIA (02) AUSTRIA BALTIC COUNTRIES BELGIUM

ORDERING INFORMATION AFRICA AUSTRALIA (02) AUSTRIA BALTIC COUNTRIES BELGIUM AFRICA +33 1 30 12 70 00 AUSTRALIA (02) 9888 8999 AUSTRIA 0820 874 464 BALTIC COUNTRIES +358 2 030 5645 BELGIUM 070 225 645 BRAZIL (011) 5548-7011 C.I.S. +33 1 30 12 70 00 CANADA (800) 645-5476 CHINA (8610)

More information

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer Simplicity Accuracy Durability Lotix Automated High Temperature Combustion TOC Analyzer The Lotix TOC Combustion analyzer is designed to accurately measure carbon content in aqueous matrices down to the

More information

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography Application Note 206 Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography Introduction The Bayer Process is used to isolate alumina (Al 2 O ) from bauxite. In this process,

More information

BRAVO. Innovation with Integrity. The next generation handheld Raman spectrometer. Raman

BRAVO. Innovation with Integrity. The next generation handheld Raman spectrometer. Raman BRAVO The next generation handheld Raman spectrometer Innovation with Integrity Raman BRAVO Raises Standards. BRAVO sets new standards in performance, safety and ease of use of handheld Raman analyzers

More information

oil standards TRUE NORTH AND ATLANTIS

oil standards TRUE NORTH AND ATLANTIS oil standards TRUE NORTH AND ATLANTIS Accuracy Matters Accurate lab data is critical to sound decision making. Running certified oil standards is the ideal way to ensure the accuracy of your DGA results.

More information

0UltraClean. Ion Exchange Resins for Ultra-pure Water in the Electronics and Semiconductor Industry

0UltraClean. Ion Exchange Resins for Ultra-pure Water in the Electronics and Semiconductor Industry Ion Exchange Resins for Ultra-pure Water in the Electronics and Semiconductor Industry Lenntech info@lenntech.com www.lenntech.com Tel. +31-15-261.09.00 Fax. +31-15-261.62.89 0UltraClean Introduction Since

More information

World-leading LC/MS/MS technology for quantitation and identification API LC/MS/MS System

World-leading LC/MS/MS technology for quantitation and identification API LC/MS/MS System World-leading LC/MS/MS technology for quantitation and identification API 3000 LC/MS/MS System rel Accelerate your drug development cycle The API 3000 LC/MS/MS System leads the field in sensitivity, specificity,

More information

ONLINE TOC ANALYZER B-Series

ONLINE TOC ANALYZER B-Series ONLINE TOC ANALYZER B-Series Features of Online TOC Analyzers Unique, Patented Two Zone Furnace Design Having two temperature zones assure complete combustion of carbon and nitrogen containing compounds

More information

DOW PuraGuard Propylene Glycol USP/EP. Your Security for Purity

DOW PuraGuard Propylene Glycol USP/EP. Your Security for Purity DOW PuraGuard Propylene Glycol USP/EP Your Security for Purity Purity Plus A very high dedication to consistent quality and purity governs the entire product supply process for DOW PuraGuard Propylene

More information

rios Water Purification system The standard for laboratory-grade water

rios Water Purification system The standard for laboratory-grade water rios Water Purification system The standard for laboratory-grade water The laboratory-grade water solution RiOs water purification systems are ideal for the production of laboratory-grade water, which

More information

Zinc Testing and On Site Calibration for Water Testing Detection Range: 1 15ppm

Zinc Testing and On Site Calibration for Water Testing Detection Range: 1 15ppm Document: AND Zinc 100 10 2012 Zinc Testing and On Site Calibration for Water Testing Detection Range: 1 15ppm October, 2012 Edition 2 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table of

More information

Uranium Testing and Site Calibration for Water Testing Detection Range: 2 60ppb

Uranium Testing and Site Calibration for Water Testing Detection Range: 2 60ppb Document: AND Uranium 100 10 2012 Uranium Testing and Site Calibration for Water Testing Detection Range: 2 60ppb October, 2012 Edition 1 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table

More information

PRIMARY GRADE WATER. PURELAB Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists

PRIMARY GRADE WATER. PURELAB Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists PRIMARY GRADE WATER PURELAB Prima Primary Grade Water Purification Systems The Laboratory Water Specialists PURELAB Prima The simple and dependable choice for primary grade water The PURELAB Prima range

More information

Ramsey Checkweigher Systems

Ramsey Checkweigher Systems It s All About Control Ramsey Checkweigher Systems Analyze Detect Measure Control TM The process of creating the perfect checkweigher for your application is easy using the clearly defined capabilities

More information

Determination of Manganese in Brine ( 30% NaCl)

Determination of Manganese in Brine ( 30% NaCl) Application Update 8 Determination of Manganese in Brine ( 0% NaCl INTRODUCTION Sodium chloride brines are used in chlor-alkali cells and must have low concentrations of alkali and alkaline earth metals

More information

Pharmacopoeial Reference Standards

Pharmacopoeial Reference Standards Pharmacopoeial Reference Standards Industry view point Antony Raj Gomes Head- Quality Management 1 Presentation Overview Indian Industry an update Available guidelines Industry practices Current challenges

More information

Fully Automated EIA System. True open flexibility.

Fully Automated EIA System. True open flexibility. True open flexibility www.triturus.com The immunoassay analyzer of choice: completely open, fully automated, multi-test and multi-batch. TRUE OPEN FLEXIBILITY What is Triturus? Triturus is a completely

More information

Cleaning Validation: A Timely Solution for Improving Quality and Containing Cost

Cleaning Validation: A Timely Solution for Improving Quality and Containing Cost : A Timely Solution for Improving Quality and Containing Cost by Christopher Crone This article presents an economic case for the use of on-line Total Organic Carbon (TOC) and conductivity analysis for

More information

SECTIOn 4. Claritas PPT Multi-Element Standards for ICP-MS

SECTIOn 4. Claritas PPT Multi-Element Standards for ICP-MS SECTIOn 4 Claritas PPT Multi-Element Standards for ICP-MS Your Science is Our Passion. Claritas PPT Multi-Element Standards for ICP-MS The great precision, sensitivity, and rapid analysis of multi-element

More information

Functionality. Normal Operation

Functionality. Normal Operation Application Note Automating EPA Method 200.8 using the SDXHPLD High Performance Liquid Dilution System Jim Maximovich, Teledyne CETAC Technologies, Omaha, NE, USA, Jim.Maximovich@Teledyne.com The SDX HPLD

More information

Agilent Resources for Workflow Compliance MEASURING ELEMENTAL IMPURITIES IN PHARMACEUTICAL MATERIALS

Agilent Resources for Workflow Compliance MEASURING ELEMENTAL IMPURITIES IN PHARMACEUTICAL MATERIALS Agilent Resources for Workflow Compliance MEASURING ELEMENTAL IMPURITIES IN PHARMACEUTICAL MATERIALS AGILENT SOLUTIONS USP / & ICH Q3D Implementing Elemental Impurities Tests in the Pharmaceutical

More information

Halogen Moisture Analyzers

Halogen Moisture Analyzers Halogen Moisture Analyzers HB43-S, HG63 and HR83 Fast Precise Reliable Top Performance with Halogen Technology Applications High-Speed Precision For a wide application range Whenever the correct moisture

More information

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography Agilent 7693A Series Automatic Liquid Sampler Inject new performance into your gas chromotography Agilent 7693A Series Automatic Liquid Sampler A powerful combination of productivity and flexibility How

More information

Milli-Q Reference Water Purification System

Milli-Q Reference Water Purification System Milli-Q Reference Water Purification System The reference for ultrapure water systems EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Ultrapure Water by EMD Millipore Scientists today face

More information

The New Standard in Automated Preparation of Reference Materials

The New Standard in Automated Preparation of Reference Materials The New Standard in Automated Preparation of Reference Materials With for Standard Preparation your analytical testing results will reach a new level of significance and validity never realized before.

More information

Is There an Accurate Low-Conductivity Standard Solution?

Is There an Accurate Low-Conductivity Standard Solution? Is There an Accurate Low-Conductivity Standard Solution? Matthew Gingerella Rosemount Analytical Uniloc Division John A. Jacanin Chiron Technologies Certified low-conductivity solutions down to 10 microsiemens/cm

More information

Pharmaceutical Reference Standards: Overview and Role in Global Harmonization

Pharmaceutical Reference Standards: Overview and Role in Global Harmonization Matthew Borer, Ph.D., Advisor Pharmaceutical Reference Standards: Overview and Role in Global Harmonization 3rd DIA China Annual Meeting Beijing, China, 16-18 May, 2011 What is a Pharmaceutical Reference

More information

GOOD LABORATORY PRACTICE Agilent Cary 8454 UV-Visible Spectroscopy System

GOOD LABORATORY PRACTICE Agilent Cary 8454 UV-Visible Spectroscopy System GOOD LABORATORY PRACTICE Agilent Cary 8454 UV-Visible Spectroscopy System Introduction The objective of good laboratory practice (GLP) is to obtain accurate and precise results, using a measurement system

More information

Kaye Product Line Calibration and Maintenance Service Solutions Rental

Kaye Product Line Calibration and Maintenance Service Solutions Rental Kaye Product Line Calibration and Maintenance Service Solutions Rental Amphenol Advanced Sensors EUROPE Value-added services that enhance your productivity Your Validation and Monitoring equipment is

More information

Milli-Q Reference Water Purification System. The reference for ultrapure water systems

Milli-Q Reference Water Purification System. The reference for ultrapure water systems Milli-Q Reference Water Purification System The reference for ultrapure water systems Ultrapure water by Merck Millipore Easily prepare solutions with the low flow function to precisely adjust the meniscus

More information

SOP SMPS BaltimorePM supersite Version 2 November 20, 2000 Page 1 of 1. SEAS Chemistry

SOP SMPS BaltimorePM supersite Version 2 November 20, 2000 Page 1 of 1. SEAS Chemistry Page 1 of 1 RP DRAFT - MEASUREMENT AND ANALYSIS OF THE CHEMICAL COMPOSTION OF THE AMBIENT AEROSOL USING SEAS Identification code: RP RP Working RP pages APPROVALS Issue Date: /. Local PI: / / Revision

More information

Preparation of Reagent Water

Preparation of Reagent Water General 07_02_09.003 Dates Active: March 15 th, 2018 - Present Preparation of Reagent Water 1 INTRODUCTION Preparation of reagent water is one of the most important processes in the laboratory. Purified

More information

ENVIRONMENTAL (BOTTLES)

ENVIRONMENTAL (BOTTLES) 391 Safe-T-Lock Polypropylene Sample Vials w/locking Cap, Excel Safe-T-Lock sample vials one of the few air-tight, leak-proof, snap cap vials on the market. They are ideal for all types of sampling and

More information

Practical guidance for switching between anion and cation analysis systems

Practical guidance for switching between anion and cation analysis systems TECHNICAL NOTE 729 Practical guidance for switching between anion and cation analysis systems Authors Introduction Manali Aggrawal and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA Ion chromatography

More information

z /zr/r/ lnitials: tv4'wl z"z{-t L 3 /, /tt Operation and Calibration of the Dissolved Oxygen Meter Revision 5 Approval: Laboratory Man ager/lqao/rso

z /zr/r/ lnitials: tv4'wl zz{-t L 3 /, /tt Operation and Calibration of the Dissolved Oxygen Meter Revision 5 Approval: Laboratory Man ager/lqao/rso QAM.I-1 13 Operation and Calibration of the Dissolved Oxygen Meter Revision 5 Approval: Laboratory Man ager/lqao/rso Date z /zr/r/ Date z"z{-t L Effective date: Renewal date: * 1r i l: 3 /, /tt lnitials:

More information

TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700

TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700 TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700 UV / Heated Persulfate Method Ozone / Hydroxyl Radical Method Combustion Method Ultrapure Method The Series 6700 covers a complete range of Total Organic Carbon

More information

CENTRA. Centralized laboratory water systems

CENTRA. Centralized laboratory water systems CENTRA Centralized laboratory water systems 98-99 Chapter Title CENTRA Water is all we do. We know water. We recognize that a fundamental element in designing or upgrading a laboratory is planning space

More information

Available online at ScienceDirect. Procedia Engineering 132 (2015 )

Available online at  ScienceDirect. Procedia Engineering 132 (2015 ) Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 132 (2015 ) 811 815 The Manufacturing Engineering Society International Conference, MESIC 2015 Metrological Regulations for

More information

Passion. Power. Productivity. Corporate Headquarters

Passion. Power. Productivity. Corporate Headquarters Corporate Headquarters Dionex Corporation 1228 Titan Way P.O. Box 3603 Sunnyvale, CA 94088-3603 Tel: (408) 737-0700 Fax: (408) 730-9403 Worldwide Sales and Service North America U.S./Canada (847) 295-7500

More information

EXTRACTION OF BIOLOGICAL TISSUES FOR AROMATIC AND CHLORINATED HYDROCARBONS

EXTRACTION OF BIOLOGICAL TISSUES FOR AROMATIC AND CHLORINATED HYDROCARBONS EXTRACTION OF BIOLOGICAL TISSUES FOR AROMATIC AND CHLORINATED HYDROCARBONS Donell. S. Frank, Bo Wang, Juan A. Ramirez, Susanne J. McDonald, Rebecca Price, and James M. Brooks TDI-Brooks International/B&B

More information

integrity and improved efficiency

integrity and improved efficiency Kalrez perfluoroelastomer parts for integrity and improved efficiency in pharmaceutical processing Efficiently protecting process integrity is a challenge for all pharmaceutical manufacturers Today s pharmaceutical

More information

GLOBAL SERVICES WORLDWIDE TECHNICAL SUPPORT AND SERVICES ACROSS THE AMETEK LAND RANGE OF PRODUCTS QUALITY CUSTOMER SOLUTIONS

GLOBAL SERVICES WORLDWIDE TECHNICAL SUPPORT AND SERVICES ACROSS THE AMETEK LAND RANGE OF PRODUCTS QUALITY CUSTOMER SOLUTIONS GLOBAL SERVICES WORLDWIDE TECHNICAL SUPPORT AND SERVICES ACROSS THE AMETEK LAND RANGE OF PRODUCTS QUALITY CUSTOMER SOLUTIONS Repair Service Center Service Contracts/ Extended Warranty Spares Factory Calibration

More information

Water Purification System

Water Purification System Water Purification System Heal Force leads you to healthier life Heal Force R NW Series Ultrapure Water System NW series ultrapure water system can be connected directly to tap water source.the system

More information

For simple and accurate mechanical calibration.

For simple and accurate mechanical calibration. For simple and accurate mechanical calibration. Regulatory Specifications and Recommendations Changes since 2007 in regulatory specifications now also allow enhanced mechanical calibration of dissolution

More information

Milli-Q Reference Water Purification System. The reference for ultrapure water systems

Milli-Q Reference Water Purification System. The reference for ultrapure water systems Milli-Q Reference Water Purification System The reference for ultrapure water systems Ultrapure water by Merck Millipore Easily prepare solutions with the low flow function to precisely adjust the meniscus

More information

USP Perspective on Pharmaceutical Waters. Antonio Hernandez-Cardoso, M.Sc. Senior Scientific Liaison September 7, 2017

USP Perspective on Pharmaceutical Waters. Antonio Hernandez-Cardoso, M.Sc. Senior Scientific Liaison September 7, 2017 USP Perspective on Pharmaceutical Waters Antonio Hernandez-Cardoso, M.Sc. Senior Scientific Liaison September 7, 2017 Why is Water Important? Raw material Solvent Ingredient Reagent Cleaning agent (hot

More information

Good Weighing Practice

Good Weighing Practice Good Decisions For Safe Weighing Good Evaluation Good Selection Good Installation Good Calibration Good Weighing Practice Guaranteed Quality Minimized Risk Reduced Costs Secure Audits Good Operation www.mt.com/gwp

More information

The next generation FT-NIR spectrometer. Innovation with Integrity FT-NIR

The next generation FT-NIR spectrometer. Innovation with Integrity FT-NIR TANGO. Analysis to go. The next generation FT-NIR spectrometer. Innovation with Integrity FT-NIR Tango CREATES VALUES. Straight forward analyses without delays. Faster, simpler, more secure - with TANGO

More information

OVIVO PHARMACEUTICAL SOLUTIONS SOLUTIONS FOR PURIFIED WATER, HIGHLY PURIFIED WATER AND WATER FOR INJECTION.

OVIVO PHARMACEUTICAL SOLUTIONS SOLUTIONS FOR PURIFIED WATER, HIGHLY PURIFIED WATER AND WATER FOR INJECTION. Worldwide Experts in Water Treatment SOLUTIONS FOR PURIFIED WATER, HIGHLY PURIFIED WATER AND WATER FOR INJECTION Manufactured and preassembled by Ovivo Constructed in pre-mounted, fully divided plant sections

More information

CENTRALIZED SYSTEMS CENTRA. Packaged central laboratory water systems. The Laboratory Water Specialists

CENTRALIZED SYSTEMS CENTRA. Packaged central laboratory water systems. The Laboratory Water Specialists CENTRALIZED SYSTEMS CENTRA Packaged central laboratory water systems The Laboratory Water Specialists CENTRA A unique range of packaged centralized systems for supplying pure water to one or more laboratories

More information

Best Practices for Filtration of Dissolved Metals

Best Practices for Filtration of Dissolved Metals Best Practices for Filtration of Dissolved Metals Tim Crowther, Regional Client Services Manager ALS Environmental, Canada Right Solutions Right Partner www.alsglobal.com 1 Right Solutions Right Partner

More information

PURELAB Chorus 2 Innovation and Flexibility

PURELAB Chorus 2 Innovation and Flexibility PURELAB Chorus 2 Innovation and Flexibility Lab Water Purification Solutions for your Research Needs PURELAB Chorus 2 + (RO/EDI/UV) (RO/EDI/UV) PURELAB Chorus 2 + Type II + Water Liters per day: 1-120

More information

ACCURACY THE FIRST TIME. Reliable testing with performance, productivity and value combined AB SCIEX 3200MD SERIES MASS SPECTROMETERS

ACCURACY THE FIRST TIME. Reliable testing with performance, productivity and value combined AB SCIEX 3200MD SERIES MASS SPECTROMETERS ACCURACY THE FIRST TIME Reliable testing with performance, productivity and value combined AB SCIEX 3200MD SERIES MASS SPECTROMETERS Reliability, reproducibility, and confidence in your data Your routine

More information