1 2008 Oregon Residential Specialty Code Changes Effective April 1, 2008 (Except, a grace period exists until June 30, 2008 where either the existing or the new code may be uses. But, the two can not be mixed.) The Electrical and Plumbing provisions are no longer in the Oregon Residential Specialty Code. Appendix O, Row Houses, no longer exists. Appendix N, Low-rise Multiple Family structures is no longer in the residential code. Provisions are in the Structural Code. Chapter 1 - Administration R105.2 Work exempt from permit. #1 Non-habitable, added used as tool and storage sheds, playhouses and similar uses,....#5 added platforms, removed 30 inch rule. R106.1 Submittal Documents. Statement of special inspections required. R109.1 General. Work to remain accessible and exposed until approved. R Reinforced masonry, insulating concrete form (ICF) and conventionally formed concrete wall inspection. R110.1 Certificate of Occupancy required. Shall include names of contractors among other items. (C of O required as of April 1 regardless of code used.) R Moisture Content. After framing and prior to installation of interior finishes, the Building Official shall be notified in writing by the general contractor that all moisture-sensitive wood framing members have a moisture content of not greater than 19% of the weight of dry wood. Chapter 3 Building Planning Several new definitions have been added. R NEW Seismic Zone E. (Oregon doesn t have any E categories) Table R301.5 Uniformly Distributed Loads. Sleeping Rooms are now allowed to be designed for 30 psf. R302 Exterior Wall Location (Fire separation distances) Section is completely rewritten. See tables. R303.1 Habitable Rooms. Added #3. Use of sunrooms.... R Light Activation. shall be a wall switch at each floor level where the stairway has six or more risers. R308.1 Identification (safety glazing) a label is now allowed in lieu of etching, embossing, etc. R Other Penetrations. Penetrations through the garage separation must be filled by an approved material to resist passage of flame and gas. R309.2 Separation Required. New language allows detached garages less than 3 feet from dwelling when protected w/ ½ gypsum wall board on the inside of the garage. R310.1 Emergency Escape and Rescue Openings. R Minimum opening height. net clear opening height shall be 24 inches (610mm).

2 R310.5 Emergency escape windows under decks, porches and similar projections. Now allowed when a 36 inch high path is maintained. R Landings at doors. Allowed slope 2%. Exception: #1 change from two to three or fewer risers. R Maximum slope (Ramps). Changed to 1:12 (8.3%) slope with an exception for 1:8 (12.5%) where infeasible. SECTION R317 Dwelling Unit Separation.. Most of this is new under Townhouse. Looks as if they moved the a lot of the Rowhouse information to here. R317.1 Two-family dwellings. New exception for fire separation wall allowing attic draft stop when ceilings are 5/8 Type-X gypsum wall board. R318.2 Moisture Content. After framing and prior to installation of interior finishes, the Building Official shall be notified in writing by the general contractor that all moisture-sensitive wood framing members have a moisture content of not greater than 19% of the weight of dry wood. R319.1 Location Required (Protection against decay) treated in accordance with AWPA U1..shall be listed in Section 4 of AWPA U1. R Field cuts treated in accordance with AWPA M4. R319.1 Protection Against Decay. Item 2 now includes all sill plates in contact with concrete or masonry foundation walls. R Exposed glue-lam timbers. Pressure Treated or decay resistant wood. R319.3 Fasteners. Coating requirements for zinc-coated. NEW SECTION R323 ELEVATORS AND PLATFORM LIFTS. Section R323 Flood-Resistant Construction is now Section R324. R Elevation requirements. Elevations minimum of 1 foot above... ADD #4. Chapter 4 Foundations R Drainage- Impervious surfaces within 10 ft., 2 % slope away from the building. R Wood treatment retention level has been removed. Now refers to AWPA U1. Table R403.1 All minimum footing sizes are 12. R Seismic reinforcing- footings w/ stem walls, (1) #4 within 3to 4 inches of the bottom of the footing. R Frost protection- protection not required for freestanding accessory structures 600 sq, ft. or less for light framed construction. R Foundation anchorage- walls 24 or shorter require (1) ½ inch anchor bolt, walls 12 and shorter require no foundation anchorage. R Foundation anchorage in Seismic Design Categories C, D 1 -and D 2. 3 x 3 x.229 plate washers shall be required for all braced wall lines (ext. walls). R Seismic Design Categories D1 and D2. Item 6: Vertical reinforcement of one #3 max 4 feet on center. Tied to horizontal in footings. Deleted paragraph of Vertical reinforcement added more information and new Tables. TABLE R (2) Lots of new information added, as well as Table R (3); Table R (4); and Table R (5).

3 R Retaining walls- walls that are not laterally supported at the top and retain in excess of 48 of unbalanced back fill shall be designed Chapter 5 Floors NEW R Structural log members. NEW R Framing at braced wall lines. Load path for lateral forces. Table R (1) New footnote a. Dead load limits for townhouses. Same for Table (2) New footnote b. (same as above) Table R502.5(1) New column for ground snow load of 70 psf Table R (1) New column for Allowable live load. NEW R Floor trusses. For cold-formed steel trusses. R505.2 Structural framing. Hole in joist webs conditions: 6 New conditions. Figure R505.2(3) Has been slightly modified. R Allowable joist spans. ADDED Blocking. R Hole patching. New Re-written. NEW R Reinforcement support. Chapter 6 Wall Construction Table R602.3(2) Alternate Attachment table has been modified R602.3 Design and construction. Exterior walls...studs shall be continuous from a support at the bottom to a support at the top to resist loads perpendicular to wall. The support shall be a foundation or floor, ceiling or roof diaphragm or shall be designed in accordance with accepted engineering practice or other methods approved by the Building Official. R602.6 Drilling and notching-studs 2. Drilling change from 40 % to 60% of stud width.....drilled over 40 % up to 60% shall also be doubled with not more than 2 successive double studs bored. R602.8 Fireblocking required. Item 4 now includes around cables and wires. R Arrangement has been changed. New R Alternate braced wall panel adjacent to a door or window opening. Figure R R Connections. This section has been greatly added to. It now includes R Sole plate connections. R Foundation sill plate connections. R Top plate connections. Provides prescriptive details to connect cantilevered or stub heel trusses to braced wall line. R Bracing in Seismic Design Categories C, D1, and D2 has been divided into 3 sections; R Braced wall line spacing. R Braced wall panel location. And R Collectors. (NEW) Renumbered from R to R Two or less horizontally attached units. R renumbered from R Three or more horizontally attached units. No tie-down device for a one-story or top of two or three story.

4 New R Wall anchorage. Plate washers minimum 3x3 inches. Hole requirements. No exceptions. Per IRC model code Few changes to Sections R603 through R612, model code changes. Steel wall framing, masonry construction and the use of ICF blocks. Chapter 7 Wall Covering New section from IRC model code. R Horizontal gypsum board diaphragm ceilings. R Water-resistant gypsum backing board. R Limitations. Table R R renamed to Cement, fiber-cement and glass mat gypsum backers. Gypsum backer has been completely deleted. R703.1 General. Has been added to and all Exceptions from the IRC model code. Exception 1. weather-resistant changed to water-resistant. R703.2 changed to Water-resistive barrier. One layer of No. 15 asphalt felt. Has been added to and exceptions has changed. R703.4 Attachments. Added information for basic wind speed of 110 mph or higher. Table R703.4 Weather-Resistant Siding Attachment. Several of the siding materials has been added to column where water-resistive barrier is required. New Section per IRC model code R Water-resistive barriers. R703.7 Stone and masonry veneer, general. Conditions have been removed. Exceptions added; See IRC model code. OREGON has added Exception 3. IRC Model Code. New Table 703.7(1) and Table 703.7(2). New Figure R703.7(1). R703.8 Flashing. Slight changes in wording. 1. has been completely replaced. NEW R Vinyl siding. R Installation. Per IRC model code. Chapter 8 Roof-Ceiling Construction NEW section R Structural log members. R802.2 Design and construction. Added minimum slope 3:12 (25%). R Ceiling joist and rafter connections. Removed Table R602.3(1). Second and Third paragraphs have been deleted and replaced Per IRC model code. Rafter ties min. 2x4 in. Table R802.5(1) thru R802.4(2), the Rafter Span Adjustment Factor numbers in footnote has changed. NEW section R Applicability limits. Per IRC Model Code. R Bracing. Added BCSI SECTION R804 STEEL ROOF FRAMING R Roof trusses. Truss members shall not be notched, cut....without approved design. R Applicability Limits. Rafter or truss span Change from 36 to 40 feet in width. Height limitation deleted. R804.2 Structural framing. Condition 4 & 5 added. R Material. Number 4 changed. Figure R804.2(3) Minor changes.

5 Tables R (1) thru R (8) are new tables. R Hole patching. Now as per IRC Model Code. Tables R (1) and R Have been modified. NEW R806.4 Unvented attic assemblies. Oregon has added verbage. Chapter 9 Roof Assemblies NEW R903.5 Hail exposure. R Moderate hail exposure. R Severe hail exposure. Per IRC Model Code. NEW R Wind resistance of asphalt shingles. Per IRC Model Code. R Attachment. Class F added. NEW R Ice barrier. Reworded. Changed R Material standards. Per IRC Model Code. NEW R Ice barrier. NEW R Ice barrier Changed R Underlayment. NEW R Ice barrier. Changed R Underlayment. NEW R Ice barrier. Table R minor change. R Slope. Re-arranged. R Material standards. Per IRC Model Code. TWO NEW TABLES R (1) and R (2) Per IRC Model Code. NEW R906.2 Material standards. And Table R906.2 Per IRC Model Code. R907.3 Re-covering versus replacement. ADD condition 4 and Exception 3 all reads per IRC Model Code. Chapter 10 Chimneys and Fireplaces THIS CHAPTER HAS BEEN REARRANGED DELETE R Mantel and trim. R1006 has been changed to SECTION R1002 MASONRY HEATERS. This seems to follow IRC Model Code as well as SECTION R1003 MASONRY CHIMNEYS. Changed from R1001 Table R (1) changed to Table R (1). Table R (2) changed to Table R (2) This table is completely different. R Chimney fireblocking..... beams or headers shall be self-supporting or.... SECTION R1005 FACTORY-BUILT CHIMNEYS was R1002. Changes follow IRC Model Code. SECTION R1006 EXTERIOR AIR SUPPLY was R1005 Chapter 11 Energy Efficiency (OREGON ONLY) R Change of occupancy or use. This section more specific.

6 NEW Section N Change of use. And Section N Change of occupancy. Both refers to Table N1104.1(2) Footnote d. N Additions. Exception ADDED. 30% of existing building heated space floor are or 400 square feet, not required to comply with Table (2). NEW Table N1101.1(1). Standard Base Case and Log Homes Only. NEW Table N1101.1(2) Additional Measures (select one) in addition to Table N1101.1(1). N General. Reworded to use new Tables. ADDED to incorporate passive solar elements. Table N1104.1(1) Rearranged. ADDED two footnotes about skylights & Exterior door. N Windows. ADDED Requirement #3. NEW N Intermediate framing for walls. 1. Walls. 2. Corners and intersections. 3. Headers. NEW N Slab-on-grade floors with hydronic heat. N CHANGED TO Vapor retarders. Numbers 1, 2 & 3 have been removed. Exceptions remain with one added Below grade walls are not required to have a vapor retarder. N Insulation of ducts. ADDED Exception: existing ducts not required to be insulated to current code. NEW N Outdoor thermostat required. N Heat pumps. More specific and HSPF not less 7.7 and SEER 13. NEW N Air conditioners. NEW N Furnaces. N Oil-fired furnaces. N Gas-fired furnaces. NEW N Boilers. N Packaged terminal air conditioners. N Packaged terminal heat pumps. Same table NEW number. Was Table N ; NEW number Table N NEW SECTION ADDED. SECTION N1107 LIGHTING. N General. N High-efficiency interior lighting systems. (New 50% rule) SECTION NA1107 CHANGED TO NA1108 Chapter 12 thru 24 Mechanical Administration M Scope. ADDED Systems not addressed refer to Section R REMOVED Section M1203 Service Utilities. MOVED TO Section R111. M All appliances shall have a 30 x 30 clear work space on the control side of the appliances. M Attic and under floor appliance passageways have been extended to a maximum of 50 ft in length when the passageway is 6 ft in height and 22 in wide. M Added new exception. Passageway unobstructed and not less than 6 feet high and 22 inches wide for its entire length, shall not be limited.

7 N Natural ventilation. CHANGED. Reads as per IRC Model Code. M Mechanical ventilation. ADDED...source of ignition is below the mechanical ventilation outlet(s). reads the same as per IRC Model Code. M Foundation and supports for outdoor mechanical systems shall be 3 inches above grade. M Auxiliary & secondary drains shall slope 1%. (1/8 unit vertical in 12 units horizontal) M Item 4A water level detection device may replace an auxiliary/secondary drain if it conforms to UL 508. M Exception Fuel-fired appliances that automatically shut down in the event of a stoppage, needs no auxiliary drain pan. Changed M1501 to General. Each Section has been bumped up one. For Exp. M1501 is now M1502. M A mechanical exhaust system shall be discharged to the outdoors, and shall not be discharged into an attic, soffit, ridge vent, or crawlspace. M Clothes dryer exhaust must terminate not less than 3 feet from an opening M Clothes dryer ducts shall be at least 4 inches in diameter. M The entire clothes dryer exhaust ducts, excluding transition ducts shall be supported and secured in place. M Exception #2 Booster fans are no longer an exception for the maximum length of 25 feet for a clothes dryer duct. A new exception allows for large radius bends as an alternative method. M All Exhaust air shall be exhausted directly to the outdoors. M & M There is a new sound rating for exhaust fans: 1.0 sone for continuous fans and 3.0 sone for intermittent fans. (bath fans) Table M Exhaust rates for residential Dwellings have changed. M General. Ductless hoods Exception has been deleted. NEW M Clearance. Construction not less than 28 gage metal and clearance of at least 24 inches. 2 Exceptions. Kitchens cfm intermittent or 25 cfm continuous Bathing and spa facilities - 80 cfm intermittent or 20 cfm continuous Toilet rooms without bathing facilities 50 cfm Table M New Exhaust duct sizing chart CFM Minimum Flex Max Length Minimum Ridged Max Length Max elbows (diameter) (diameter) (a) 50 4" 25 ft 4" 70 ft 3 5" 90 ft 5" 100 ft 3 6" No Limit 6" No Limit " (b) N/A 4" 20 ft 3 5" 15 ft 5" 100 ft 3 6" 90 ft 6" No Limit 3 a. For each additional elbow subtract 10 feet from length b. Flex ducts of this diameter are not permitted with fans of this size M Bath fans must be controlled by a de-humidistat, timer or similar means of automatic control.

8 M All ducts shall be mechanically fastened. 1. Flex ducts fasteners must comply with UL181B & 181B-C 2. Ridged ducts must have 3 screws or rivets equally spaced ADDED M1906 GASEOUS HYDROGEN SYSTEMS M Installation. In accordance with the applicable requirements of Sections M and M and the Mechanical Code and the Fire Code and the Building Code. M Testing. Included an Exception for continuous loop systems using PEX or PP tubing. Test pressure allowed 100 psi for 30 minutes. NEW M Pressurizing during installation. If imbedded in concrete, pressure test before and during pour. M Piping joints. ADDED a 3 rd requirement. PP tubing installed according to manufacturer s instructions. NEW DEFINITIONS ALL PER IRC Model Code CONNECTOR, APPLIANCE (Fuel) CONNECTOR, CHIMNEY OR VENT. REGULATOR, MEDIUM-PRESSURE (MP Regulator) VENT PIPING. POINT OF DELIVERY. Deleted last sent that reduces pressure to 2 psig. NEW G Auxiliary drain pan. READS AS PER G (307.5) IRC Model Code NEW G Engineered wood products. PER IRC Model Code. G Prohibited locations. This section has been re-written and reads the same as IRC Model Code G (303.3). NEW G Regulator vent piping. PER IRC Model Code. G Prohibited locations. ADDED....shall not extend through any townhouse unit.. G Protection against physical damage. Holes or notches increased to 1.5 inch from the nearest edge of the member, shall protect by shield plates. and shall extend a minimum of 2 inches above sole plates, etc. G Piping in solid floors. ADDED last sentence. Vent conduit above grade to outdoors and prevent the entry of water and insects. NEW TABLE G MANUAL GAS VALVE STANDARDS NEW G Vent piping. G Connecting appliances. ADDED #2 Corrugated stainless steel tubing (CSST), others 2, 3, 4 changed to 3, 4, 5, ADDED #6. CHANGED AND ALL NEW. G Connector installation. G Maximum length. G Minimum size. G Prohibited locations and penetrations. G Shutoff valve. NEW G Protection against physical damage.

9 G Chimney termination. ADDED residential-type or low-heat appliances. Chimneys for medium-heat appliances shall extend at least 10 feet higher than any portion of any building within 25 feet. G Gas vent termination. Changed from G DELETED #1 and replaced with new verbiage ADDED #2. #2 is now #3 and so on. NEW G Roof terminations. G Forced air inlets. As per IRC Model Code G and G NEW G Vent offsets. Type B and L.... G Passage through ceilings, floors or walls. Wording has change Exception has been deleted. NEW G Tee and wye fittings. Per IRC Model Code. NEW G Draft hood conversion accessories. Per IRC Model Code. G Unvented decorative room heaters. (name change) NEW G Ventless firebox enclosures. Per IRC Model Code. M Hydronic piping has added cross-linked polyethylene (PEX) tubing and polypropylene (PP) as approved materials. M Hydronic piping joints has 2 new requirements. 1. Polypropylene joints shall be installed with socket-type heat fused polypropylene fittings. 2. Cross-linked polyethylene shall be joined using cold expansion, insert or compression fittings. M Abandoned fuel oil storage tanks must have the fill piping removed. G Holes bored in framing members within 1.5 inches of the edge of the member needs to be protected with nail plates.

Chapter 2 Definitions Several new definitions have been added. Chapter 3 Building Planning

Chapter 2 Definitions Several new definitions have been added. Chapter 3 Building Planning 2008 Oregon Residential Specialty Code Changes Effective April 1, 2008 (Except, a grace period exists until June 30, 2008 where either the existing or the new code may be uses. But, the two can not be

More information

NC 2009 Residential Code changes (Highlights on changes between the 2006 and 2009 NC Residential Code)

NC 2009 Residential Code changes (Highlights on changes between the 2006 and 2009 NC Residential Code) NC 2009 Residential changes (Highlights on changes between the 2006 and 2009 NC Residential ) Chapters 1 and 2: Administration and Definitions Section Title R101.2 Scope Added the words ABOVE GRADE. R101.5

More information

* RESIDENTIAL PLAN REVIEW *

* RESIDENTIAL PLAN REVIEW * CITY OF DES MOINES, IOWA COMMUNITY DEVELOPMENT DEPARTMENT PERMIT AND DEVELOPMENT CENTER 602 Robert D. Ray Drive DES MOINES, IOWA 50309 Phone: 515.283.4200 Facsimile: 515.283.4270 Based on the scope of

More information

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS Please note: This construction plan component list is to be used as a guide to assist you with your project. There may be elements unique to your project not

More information

Administrative Changes

Administrative Changes Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings

More information

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage The following list of code requirements is intended to assist you in complying with the Code of Public

More information

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: IRC CODE UPDATES TO: RESIDENTIAL BUILDING CONTRACTORS FROM: GARY STABER, BUILDING OFFICIAL SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: 6/1/2003 INTERNATIONAL RESIDENTIAL CODE (IRC) APPLICABILITY:

More information

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date ORDINANCE AN ORDINANCE OF THE COMMISSION OF KNOX COUNTY, TENNESSEE RESCINDING ARTICLE III. CABO ONE- AND TWO-FAMILY DWELLING CODE, SEC. 10-56, SEC. 10-57 AND SEC. 10-58 AND ADOPTING THE 2006 INTERNATIONAL

More information

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008) ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008) PERMIT SUBMITTAL CHECKLIST: Signed completed Building Permit application form. Two (2) Copies of a Certificate of Survey. Draw to scale the

More information

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches and shall be sized to carry the applicable roof and

More information

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC) Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC) Plan Check Submittal Date: Plan Check #: Permit App.# Job Address: Applicant: Phone: ( ) P.C. Engineer: Phone:

More information

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept. Residential Plan Check Addendum Page 2 of 5 Building Permit # Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept. 5 th,

More information

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from

More information

Residential Building Plans

Residential Building Plans Residential Building Plans 1. Building Site Plan indicating: a. Location of Proposed and Existing Buildings b. Location of Property Lines c. Building Setback Dimensions d. Location and Depth of Building

More information

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647. 10" Belly Band Cement board shake siding Cement board siding 7" Lap Decorative Corbels Cement board siding 7" Lap 4" Corner boards Stone Veneer on Garage wings 48" high 4" Window and Door Trim (Street

More information

APPLICATION FOR FINISHED BASEMENT PERMIT

APPLICATION FOR FINISHED BASEMENT PERMIT APPLICATION FOR FINISHED BASEMENT PERMIT REAL ESTATE TAX I.D. #: - - _ - _ 7607 W College Drive Ph: (708) 361-1804 Fax: (708) 923-7112 building@palosheights.org APPLICANTS: COMPLETE ALL ITEMS AND SUBMIT

More information

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Plan Check Submittal Date: Plan Check #: Permit App.# Job Address: Applicant: Phone: ( ) Plan Check Engineer:

More information

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued) 2000 IRC 1997 NEHRP Section Provision Section Provision Comments CHAPTER 3 BUILDING PLANNING R301 DESIGN CRITERIA R301.2.2 Seismic Provisions R301.2.2.1 Determination of Seismic Design Category R301.2.2.1.1

More information

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings Building Safety Department 400-2 nd Street South St. Cloud, MN 56301 (320) 255-7239 A building permit is required for any accessory

More information

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647. 4 12 Pitch Cement board siding 7" Lap 4" Corner boards Vertical Cedar T&G Siding 4" Window and Door Trim (Street facing facade) P.T. 6x6 : Wrapped & collared with cement board Trim. Stone Veneer on Garage

More information

Left Elevation. Front Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,842. Scale : 1/4" = 1'

Left Elevation. Front Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,842. Scale : 1/4 = 1' Plan Name 4 4" Window and door trim. (Street facing facades) 4" Corner Boards 4" Vertical Cedar Siding Left Elevation Lap siding over approved building wrap over 1 2" OSB sheathing. Front Elevation Stone

More information

GENERAL MECHANICAL SYSTEM REQUIREMENTS

GENERAL MECHANICAL SYSTEM REQUIREMENTS CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS SECTION M1301 GENERAL M1301.1 Scope. The provisions of this chapter shall govern the installation of mechanical systems not specifically covered in other

More information

2003 International Residential Building Code

2003 International Residential Building Code 2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less

More information

Elko County Building & Safety Division

Elko County Building & Safety Division Elko County Building & Safety Division 540 Court St., Suite 104, Elko, Nevada 89801 (775) 738-6816, Fax (775) 738-4581 www.elkocountynv.net Residential Design Criteria & Checklist One & Two Family Dwellings

More information

GENERAL MECHANICAL SYSTEM REQUIREMENTS

GENERAL MECHANICAL SYSTEM REQUIREMENTS CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS SECTION M1301 GENERAL M1301.1 Scope. The provisionsof thischapter shall governthe installation of mechanical systems not specifically covered in other

More information

IBC. Column added for ice shield underlayment requirement. Table R301.2(1) Table R301.2(1) Climatic and geographic design criteria

IBC. Column added for ice shield underlayment requirement. Table R301.2(1) Table R301.2(1) Climatic and geographic design criteria Chapters 1 and 2: Administration and Definitions Code Section 2003 2000 Section Title Change R101.3 R101.3 Purpose Section has been rewritten to reflect the purpose as written in the IBC. R202 R202 Definitions

More information

UCC Permit Application Procedures

UCC Permit Application Procedures How do I apply for a permit? UCC Permit Application Procedures 1. Please complete the CodeMaster Pan Review Application 2. Please provide the scope of work description and/or construction documents/plans.

More information

Advanced Ventilation for Residential applications FBC Res 2010.

Advanced Ventilation for Residential applications FBC Res 2010. Advanced Ventilation for Residential applications FBC Res 2010. Course Description Review of the Residential Ventilation requirements in the Florida Building Code, Residential 2010. I. Introduction Dean

More information

IRC 2015 Significant Changes

IRC 2015 Significant Changes IRC 2015 Significant Changes Building Planning - Chapter 3 Sec 301.2 Wind Design Criteria Ultimate design wind speed values replace basic values for 3-sec gust wind speeds in Section R301.2.1. A wind speed

More information

One and Two Family Additions

One and Two Family Additions One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES CHAPTER 10 CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES R1001.1 General. Masonry fireplaces shall be constructed in accordance with this section and the applicable provisions of Chapters 3

More information

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section ) 8-1200. International Residential Code. ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section 6-9-40) NOTE-This article

More information

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1% CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE EXAM ID: I1 80 multiple-choice questions 3-1/2-hour time limit Open book 01. GENERAL ADMINISTRATION 6% 0101. Project Administration 1% Verify that

More information

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3% CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE EXAM ID: I6 80 multiple-choice questions 3-1/2-hour time limit Open book 01. GENERAL ADMINISTRATION 3 % 0101. Project Administration 3% Verify that plans,

More information

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents.

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents. Certification: Commercial Building Inspector Exam ID: B2 Scope: A Commercial Building Inspector will be responsible for performing inspections of structures to determine compliance with the various Building

More information

General Residential Code Requirements

General Residential Code Requirements General Residential Code Requirements Dear Applicant: This is to advise that our review will be based on compliance with the requirements of the Louisiana State Uniform Construction code in accordance

More information

General Residential Code Requirements

General Residential Code Requirements Residential building code review will be based on compliance with the requirements of the Louisiana State Uniform Construction code in accordance with ACT 12 of the 2005 First Extraordinary Session of

More information

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

CODE COMPLIANCE GUIDELINE GENERAL BUILDING CODE COMPLIANCE GUIDELINE This guideline has been prepared by The Calhoun County Building Department to assist Homebuilders, General Contractors, and Owner/Builders during the construction process. The

More information

Residential Plan Review for New One and Two Family Dwellings

Residential Plan Review for New One and Two Family Dwellings The following is a list of items that are normally included in a set of construction drawings for one and two family dwellings. The items in bold depict those items that will be reviewed for during the

More information

1 AND 2 FAMILY DWELLING REQUIREMENTS

1 AND 2 FAMILY DWELLING REQUIREMENTS PLAN REQUIREMENTS: 1 AND 2 FAMILY DWELLING REQUIREMENTS All residential plans including additions and attached garages shall be designed to the current edition of the International Residential Code. Plans

More information

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection Slab on Grade & Basements: A capillary break is installed on top of all footings Slab / Pre-Drywall / Thermal Inspection A minimum of 4" of clean or washed gravel (0.5" diameter or greater) is placed over

More information

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507) Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN 55046 (507) 744-2327 fax (507) 744-5554 2006 RESIDENTIAL CONSTRUCTION CHECKLIST The following checklist has been designed

More information

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and & &01 GENERAL To be developed. All of the exceptions have to be coordinated. &02 SPECIAL USE AND OCCUPANCY &02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections &02.1.1 and &02.1.2.

More information

FRAMING INSPECTION GENERAL

FRAMING INSPECTION GENERAL FRAMING INSPECTION GENERAL 20 FRAMING INSPECTION GENERAL Tips Check habitable rooms for minimum light, ventilation and sanitation requirements. Check that stair framing meets headroom, width, and rise

More information

RESIDENTIAL BUILDING REQUIREMENTS

RESIDENTIAL BUILDING REQUIREMENTS RESIDENTIAL BUILDING REQUIREMENTS Residential Building Requirements This is an informational booklet with some of the general residential construction requirements taken from the codes adopted by Campbell

More information

RESIDENTIAL DETACHED ACCESSORY STRUCTURES

RESIDENTIAL DETACHED ACCESSORY STRUCTURES RESIDENTIAL DETACHED ACCESSORY STRUCTURES *A Building permit is required for any alteration or addition to any existing building or structure. MN State Building Code Section 1300.0120 Subpart 1 Permit

More information

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division GARAGES/ONE-STORY City of Grand Rapids Building Safety Division 218-326-7601 www.cityofgrandrapidsmn.com This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building

More information

International Code Council

International Code Council International Code Council ICC 400-2012 edition Standard on the Design and Construction of Log Structures Public Comments Draft #1 The ICC Standard Development Committee on Log Structures (IS-LOG committee)

More information

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11 Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11 Residential Inspector s Guide Building and Energy Based on the 2009 IRC, Chapters 1-11

More information

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11 Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11 Residential Inspector s Guide Building and Energy Based on the 2009 IRC, Chapters 1-11

More information

WALL CONSTRUCTION CHAPTER 6

WALL CONSTRUCTION CHAPTER 6 CHAPTER 6 WALL CONSTRUCTION SECTION R601 GENERAL R601.1 Application. The provisions of this chapter shall control the design and construction of all walls and partitions for all buildings. R601.2 Requirements.

More information

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST This list is provided as a guide to help you understand the information that must be contained on the construction drawings. This list is not all-inclusive of all building codes but is used as a general

More information

Stone and Masonry Veneer

Stone and Masonry Veneer Stone and Masonry Veneer R703.7 Stone and masonry veneer, general. Stone and masonry veneer shall be installed in accordance with this chapter, Table R703.4 and Figure R703.7. These veneers installed over

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES R1001.1 General. Masonry fireplaces shall be constructed in accordance with this section and the applicable provisions of Chapters 3 and 4. R1001.2 Footings and foundations.

More information

THE FLORIDA BUILDING CODE

THE FLORIDA BUILDING CODE THE FLORIDA BUILDING CODE 1. According to the Florida Building Code, spiral stairway treads must all be identical and rise must be sufficient enough to provide a headroom of minimum. A. 6'- 4" B. 6'- 6"

More information

2006 International Residential Code Errata (Portions of text and tables not shown are unaffected by the errata)

2006 International Residential Code Errata (Portions of text and tables not shown are unaffected by the errata) 1st through 6th PRINTING (Posted 07-25-2011) INDEX JOINTS, PIPE Slip.P3003.3.7 P2704.1 2009 International Residential Code Errata Page 1 of 1 FIRST PRINTING (Updated September 12, 2006) CHAPTER 1 ADMINISTRATION

More information

General Residential Code Requirements

General Residential Code Requirements General Residential Code Requirements Residential building code review will be based on compliance with the requirements of the Louisiana State Uniform Construction code in accordance with ACT 12 of the

More information

Town of Pawling Residential Building Permit Application

Town of Pawling Residential Building Permit Application Town of Pawling Residential Building Permit Application Property Address: Street: City: Zip: Grid Number: Zoning District: Project Description: Owners Name: Phone: H W/C Address: Street: City: State: Zip:

More information

INTERNATIONAL CODE INTERPRETATIONS

INTERNATIONAL CODE INTERPRETATIONS 2012 INTERNATIONAL CODE INTERPRETATIONS PREFACE The 2012 International Codes promulgated by the International Code Council (ICC ) comprise a comprehensive set of model regulations for the construction

More information

Town of Pawling Residential Building Permit Application

Town of Pawling Residential Building Permit Application Town of Pawling Residential Building Permit Application Property Address: Street: City: Zip: Grid Number: Zoning District: Project Description: Owners Name: Phone: (H) (W) Address: Street: City: State:

More information

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide 12/29/16 Building Guide Colorado Chapter of the International Conference of Building Officials Building Guide Colorado Chapter of the International Code Council Single Family Residential Enclosing Existing

More information

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

R CODE CHANGE PROPOSAL FORM (See instructions on page 2) CODE CHANGE PROPOSAL FORM (See instructions on page 2) Code: IRC 12/13 Sections 301.2.2.2.1 Proponent: Charles S. Bajnai, Chesterfield County, VA, ICC Building Code Action Committee 1. Delete as shown

More information

Screen & 3-Season Porches

Screen & 3-Season Porches Screen & 3-Season Porches PERMIT SUBMITAL CHECKLIST : City of New Prague Building Inspections Department 118 Central Ave N New Prague, MN 56071 (952) 758-4401 Fax (952) 758-1149 Signed completed Building

More information

#402 New Residential Submittal Checklist

#402 New Residential Submittal Checklist #402 New Residential Submittal Checklist Case #: Date: Project Name: Site Address: Application Submittal Building permit applications and plans can be submitted to the City by two methods. This checklist

More information

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction. Plan Examination 1 Plan ExaminationPurpose 2 Catch problems in advance of construction. 3 1 Discovery of problems in the field results in higher cost. 4 Can a good plan review eliminate all problems in

More information

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace NOTABLE CODE REQUIREMENTS the following list represents important code requirements that shall be implemented into construction while still maintaining full compliance with all other requirements within

More information

Module number 3 provides an on-line, self-paced training seminar on chapter 4, foundations and chapter 5, floors from the residential code of ohio.

Module number 3 provides an on-line, self-paced training seminar on chapter 4, foundations and chapter 5, floors from the residential code of ohio. Module number 3 provides an on-line, self-paced training seminar on chapter 4, foundations and chapter 5, floors from the residential code of ohio. 1 This chapter sets forth the prescriptive requirements

More information

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

A Closer Look Inspection Service 2015 IECC Residential DFW area handout 103.2 Information required on construction documents 1. Designation of the Thermal Building Envelope on the plans 2. Insulation Material and their R Value 3. Fenestration U and SHGC values 4. Area weighted

More information

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International Building Guide Colorado Chapter of the International Conference of Building Officials Colorado Building Chapter of the International Guide Code Council Single Family Residential One Story Detached Garage

More information

Garage/Accessory Structures

Garage/Accessory Structures Garage/Accessory Structures City of New Prague Building Inspections Department 118 Central Ave N New Prague, MN 56071 (952) 758-4401 Fax (952) 758-1149 Requirements for submitted Building Plans Signed

More information

SFR SUBMITTAL REQUIREMENTS

SFR SUBMITTAL REQUIREMENTS A. FEES DUE AT TIME OF PERMIT APPLICATION The following non-refundable fees will be collected at the time of application for all residential projects. 1. Building Plan Check Fee B. CODES The City of Oak

More information

Residential Patio Cover Specifications

Residential Patio Cover Specifications Residential Patio Cover Specifications This information bulletin describes the minimum requirements for obtaining patio cover permits for residential buildings using the City of Vista standard plan or

More information

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321) BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL 32907 Phone: (321) 953-8924 Fax: (321) 953-8925 CUSTOMER SERVICE INFORMATION ON RESIDENTIAL PLAN REVIEW REQUIRED DOCUMENTS MUST BE SUBMITTED AT TIME

More information

R Code and Commentary for 2012 NC Residential Code final 03/06/13

R Code and Commentary for 2012 NC Residential Code final 03/06/13 R602.10 Code and Commentary for 2012 NC Residential Code final 03/06/13 Commentary italicized and printed in red 1. Section R602.10 -- provides charging language for two simplified bracing approaches (isolated

More information

HUMBOLDT COUNTY BUILDING & SAFETY DEPARTMENT CITY OF WINNEMUCCA BUILDING DEPARTMENT

HUMBOLDT COUNTY BUILDING & SAFETY DEPARTMENT CITY OF WINNEMUCCA BUILDING DEPARTMENT HUMBOLDT COUNTY BUILDING & SAFETY DEPARTMENT CITY OF WINNEMUCCA BUILDING DEPARTMENT FOR PRIVATE THREE-SIDED POST FRAMED (NON-ENGINEERED) OUTBUILDINGS LOCATED ON RESIDENTIAL LOTS ONLY Buildings must meet

More information

Andy Schreder CBO Building Official for St Francis, Nowthen

Andy Schreder CBO Building Official for St Francis, Nowthen Andy Schreder CBO Building Official for St Francis, Nowthen Voluntary Compliance Webster says: Voluntary means from one s own choice or consent. Of their own free will Compliance is conformity in fulfilling

More information

RESIDENTIAL BUILDING PLAN REQUIREMENTS

RESIDENTIAL BUILDING PLAN REQUIREMENTS CITY OF MANSFIELD BUREAU OF BUILDING AND CODES 30 NORTH DIAMOND STREET 3RD FLOOR MANSFIELD, OHIO 44902 Phone (419) 755-9688 Fax (419) 755-9453 www.ci.mansfield.oh.us RESIDENTIAL BUILDING PLAN REQUIREMENTS

More information

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. SHED TO BE BUILT AS PER IRC, UBC OR CURRENT LOCAL CODE To the best of my knowledge

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

RESIDENTIAL CONSTRUCTION New Dwellings and Additions How to Obtain a Building Permit For RESIDENTIAL CONSTRUCTION New Dwellings and Additions MIAMI COUNTY, KANSAS CODE SERVICES DEPARTMENT 201 South Pearl Street, Suite 201 Paola, Kansas 66071-1777 Phone:

More information

One & Two Family Residential ADDITIONS

One & Two Family Residential ADDITIONS City of St. Petersburg Development Services One & Two Family Residential ADDITIONS (Effective Date: 5/1/03) This checklist is subject to change and improvement at any time. Please determine that you have

More information

Building Envelope

Building Envelope 9.36.2. Building Envelope Module 2 BCBC 9.36. 2014 1 Richard Kadulski Architect 9.36.2. Building Envelope Focus is on total building performance, not just thermal insulation Heat transfer and air leakage

More information

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department olorado Chapter of the International Conference of Building Officials Lancaster County Building Department Single Family Residential One Story Detached Garage How to Use this Guide Provide two sets of

More information

fort collins building & zoning

fort collins building & zoning fort collins building & zoning 281 N. College Ave., P.O. Box 580; Fort Collins, CO 80522-0580; Voice: 970 221 6767 FAX: 970 224 6134 Fort Collins Amendments Quick Reference Guide to 2003 International

More information

City of High Point Airport Overlay District Noise Level Reduction Design Standards

City of High Point Airport Overlay District Noise Level Reduction Design Standards City of High Point Airport Overlay District Noise Level Reduction Design Standards Part A. Residential Design Standards for Zone 3 I. NOISE LEVEL REDUCTION (NLR) REQUIREMENT FOR ZONE 3. The City of High

More information

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016 February 2016 Residential Deck Safety, Construction and Repair Juneau Permit Center, 4 th Floor Marine View Center,(907)586-0770 This handout is designed to help you build your deck to comply with the

More information

GENERAL MECHANICAL SYSTEM REQUIREMENTS

GENERAL MECHANICAL SYSTEM REQUIREMENTS CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS SECTION M1301 GENERAL M1301.1 Scope. The provisions of this chapter shall govern the installation of mechanical systems not specifically covered in other

More information

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1 16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

ROWHOUSE CONSTRUCTION

ROWHOUSE CONSTRUCTION ROWHOUSE CONSTRUCTION SECTION AO101 SCOPE AO101.1 Scope. This appendix, and other applicable provisions of this code, shall apply to the construction, alteration, enlargement, replacement, repair, equipment,

More information

2018 IRC Sections R303 through R310 Building Planning II

2018 IRC Sections R303 through R310 Building Planning II Study Session 3 2018 IRC Sections R303 through R310 Building Planning II OBJECTIVE: REFERENCE: KEY POINTS: To develop an understanding of the health and safety criteria of the code, including light and

More information

CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist

CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist This checklist is a convenient reference to the 2012 Michigan Building Code. The checklist

More information

City of Oviedo Residential Permit Application Guidelines

City of Oviedo Residential Permit Application Guidelines City of Oviedo Residential Permit Application Guidelines All permit applications must be complete prior to acceptance. A complete application shall include the following: Building Permit Application completed,

More information

Oregon Building Officials Association

Oregon Building Officials Association Oregon Building Officials Association Oregon Building Officials Association Inspector s Checklist 2010 Oregon Manufactured Dwelling Installation Specialty Code November 5, 2014 By: Frank Scheer, Building

More information

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied

More information

LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017)

LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017) LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017) It is the responsibility of the permit applicant to notify the building inspector when the work is ready for inspection. To request an

More information

2006 INTERNATIONAL MECHANICAL CODE

2006 INTERNATIONAL MECHANICAL CODE DOCUMENTATION 006 INTERNATIONAL MECHANICAL CODE Code Change No: M6-07/08 Original Proposal Table 308.6, 307..3, 506.3.., 507.4, 507.5, [F] 53.3. (IFC 909.3.; IBC [F] 90.3.), Table 603.4, 803.8, Table 803.9(),

More information

INTERIOR ENVIRONMENT

INTERIOR ENVIRONMENT CHAPTER 12 INTERIOR ENVIRONMENT > SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions,

More information