CI/SfB (37.5) X Horizontal ROOF HATCHES. Access AUTOMATIC SMOKE VENTS. We have just the opening for you! FLOOR DOORS SAFETY PRODUCTS

Size: px
Start display at page:

Download "CI/SfB (37.5) X Horizontal ROOF HATCHES. Access AUTOMATIC SMOKE VENTS. We have just the opening for you! FLOOR DOORS SAFETY PRODUCTS"

Transcription

1 Uniclass CI/SfB L41 (37.5) X 2009 D1 EPIC Horizontal ROOF HATCHES Access Products AUTOMATIC SMOKE VENTS We have just the opening for you! FLOOR DOORS SAFETY PRODUCTS

2 Bilco History The Bilco Company was established in America in 1926 and has for many decades designed and supplied access products for construction and engineering industries all over the world. Under the same family ownership the Company has been a pioneer in the development of a unique line of horizontal access products. In 1989, Bilco UK & Europe was formed and has built a reputation amongst architects, engineers, specifiers, and the construction trades for providing the right access solution. Bilco Today Bilco UK, Bury St. Edmunds, Suffolk, England Our Commitment Based in Suffolk, Bilco can supply the trade with a range of standard roof hatches, smoke vents, and floor doors in various sizes and materials direct from stock, delivered by a nationwide pallet-line system or dedicated consignment. Standard items are delivered anywhere in the UK in 3-4 working days and best of all, there s no extra charge. If a special product is required, the fast-track shop allows delivery in an industry leading 4-6 weeks. Bilco also provides technical assistance for more complex product requirements. The technical department will assist you to develop a creative design solution for your unique applications. Quality access products comply with current Building Regulations & Legislation, and are engineered to provide many years of trouble-free service. Bilco products are designed and fabricated to consistently high quality standards to ensure complete customer satisfaction. As part of its commitment, Bilco has implemented a company-wide quality system, which has achieved ISO 9001 and is working towards accreditation. The Bilco Company is committed to producing access products that are unequalled in quality, design, and workmanship. Our Guarantee Warranty is for a minimum period of ten years from the date of purchase. Electric motors, special finishes, and other special equipment, if applicable are covered separately.

3 Contents Roof Access Hatches 4-5 Ladder Access Type S, Type E 6 Ladder Access Type GS 7 Ship Stair Type NB 8 Service Stair Type L, Type SSY 9 Refurbishment VersaMount Security Access Security Series 11 Plant Access Type D, Type F, Type SS 12 Roof Hatch Options Automatic Smoke Vents Solid Covers Single Leaf Solid Covers Single Leaf Translucent Single Leaf Translucent Double Leaf Special Sizes Type D-50REM 20 Acoustic Type ACDSH 21 Controls Smoke Vent & Roof Hatch Options Floor Doors Drainage Doors Type J-AL, JD-AL 28 Drainage Doors Type J-ALH20, JD-ALH2O 29 Non-Drainage Doors Type K, KD 30 Non-Drainage Doors Type TER, TRD 31 Fire Doors Type J-FR 32 Fire Doors Type FR 33 Floor Door Options 34 Safety Products - Bil-Guard Hatch Rail System 13 LadderUp Safety Post 35 Floor Door Fall Protection Grating 35

4 Roof Hatches New enhanced Bilco roof hatches provide safe and convenient roof access by means of an interior ladder, ship stair, or service stair. Larger sized hatches are also available to facilitate the easy movements of equipment to and from a building. Each aluminium hatch comes with a year guarantee. The curb upstand is manufactured with a cap-flashing that includes the Bilclip flashing system which accepts a variety of felts and membranes. As a result installation time and related costs are greatly reduced and a more effective mechanical termination which does not rely on adhesives alone is provided. Alternatively a metal curb liner can be specified to make site installation easier, ideally suited for hot-works and standing seam roofs. Customised designs are also available which can feature security options, motorised operation, a range of paint finishes and safety aids. Heavy duty slam latch securely locks cover in the closed position. Interior and exterior hasps provide additional security Rugged hold-open arm automatically locks the cover in the open position. Grip handle allows for easy, onehand release and closing. Fully insulated cover and curb. 50mm thick faced rigid polyisocyanurate thermal insulation board. U value of 0.47Wm 2 /K Typical Applications Banks Prisons Factories Fast Food Restaurants Gymnasiums Hospitals Hotels High-Rise Housing Office Buildings Manufacturing Plants Schools Shopping Centres Storage Facilities Distribution Depots Warehouses Key Features & Benefits Weathertight construction Fully insulated and gasketed for energy efficiency Lift assistance for smooth, easy, one-hand operation Corrosion resistant hardware Bil-Clip Flashing System for ease of installation Custom sizes and options are readily available Meets the requirements of manual handling regulations Hatches can be specified with curb liners Curb Liners - Hatches can be fitted with curb liners to make site installation easier. See suffix CL. 4

5 specification on all roof access hatches! Top side latch with turn handle and padlock hasp Interior channel reinforcing members are welded in place for cover strength and rigidity. Newly designed closed cell EPDM sponge gasket, helps meet Building Regulations air leakage targets by providing a better seal of the cover to the curb, ensuring complete weather-tightness. Air leakage performance 4.83m 3 /hr/m 600 Pa Tested to BS EN 12207: 2000 Fully enclosed compression springs counter balance the cover for smooth, easy and controlled operation regardless of cover size or weight. Bilco hatches meet the requirements of Manual Handling Regulations Thermal insulation board Capflashing Meets BS EN 12207Curb Membrane (adhered to itself) Bilclip flashing system Bilclip Insulated curb with cap flashing and Bil-Clip flashing system. Installation is simply a matter of placing the hatch over the roof opening and securing it to the roof deck through the holes provided in the base flange. The integral capflashing readily accepts roofing membranes reducing installation time and costs. 5

6 Ladder Access Gasket (All Around) Cover Spring Latch with Inside-Outside Handles and Padlock Hasps Type E-50T Shown with optional Bilco LadderUP Safety Post Cover Liner Red Vinyl Grip Automatic Hold Open Arm and Cover Release 50mm Polyisocyanurate Insulation throughout cover Curb with integral Capflashing and Bilclip Combination Lock Strike and Padlock Hasp mm 187mm Lifting Mechanism with Reinforced Composite Tubes and Electrocoated Compression Springs Hinge 50mm Polyisocyanurate Insulation around outside of curb 83mm 114mm 83mm 114mm Type S-50T TYPE S-50T & TYPE E-50T - Aluminium Easy one-handed operation to fully open or closed position provides the user the security of having one hand firmly on the ladder at all times. 915mm Furnish and install where indicated on plans metal roof hatch. Length denotes hinge side. These roof hatches shall be single leaf. The roof hatch shall be pre-assembled from the manufacturer. Performance Cover shall be reinforced to support a minimum live load of Lifting Manufacturer shall provide compression spring operators characteristics: 195 kg/m 2 with a maximum deflection of 1/150th of the span or 97 kg/m 2 wind uplift. mechanisms: enclosed in telescopic tubes to provide smooth, easy, and controlled cover operation throughout the entire arc of opening and closing. The upper tube shall be the outer tube to prevent Operation of the cover shall be smooth and easy with controlled accumulation of moisture, grit, and debris inside the lower tube operation throughout the entire arc of opening and closing. assembly. The lower tube shall interlock with a flanged support Operation of the cover shall not be affected by temperature. shoe that is bolted to the curb assembly. Entire hatch shall be weathertight with fully welded corner joints on cover and curb. Hardware Heavy pintle hinges shall be provided Cover shall be equipped with a spring latch with interior and Cover: 2.3mm aluminium with a mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb. exterior turn handles Shall be equipped with interior and exterior padlock hasps. The latch strike shall be bolted to the curb assembly. Cover Shall be polyisocyanurate of 50mm thickness with a U-value of Cover shall automatically lock in the open position with a rigid insulation: 0.47 W/m 2 K. Insulation shall be fully covered and protected by an aluminium liner. hold open arm equipped with a 25mm diameter red vinyl grip handle to permit easy release for closing. Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place. Compression spring tubes shall be an anti-corrosive composite material and all other hardware shall be zinc plated and chromate sealed. Springs shall have an electrocoated acrylic finish for corrosion resistance. [ For installation in highly corrosive environments or when prolonged exposure to hot water or steam is anticipated, specify Type 316 stainless steel hardware ]. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed Curb Shall be polyisocyanurate of 50mm thickness with a U-value of within the insulation space. insulation: 0.47 W/m 2 K. Finishes: Factory finish shall be mill finish aluminium. STANDARD SIZES & WEIGHTS Options See page 24 Type Size - clear internal dimensions Overall Dimensions Weight Performance BS EN 12207:2000 Air Permeability S-50T 915mm x 760mm (H) 1143mm x 988mm 60 kg 4.83 m3/hour/m2 at 600 Pa S-50T CL 915mm x 760mm (H) 1143mm x 988mm 66 kg BS EN 12208:2000 Water Tightness Class 9A E-50T 915mm x 915mm 1143mm x 1143mm 65 kg BS EN 122:2000 Wind Resistance Class E2400 E-50T CL 915mm x 915mm 1143mm x 1143mm 72 kg BS EN Snow Load 1200Pa for 1 hour 50 - Aluminium (H) - Hinge Side CL - Curb Liner BS 8200 Impact Resistance Pass BS EN ISO 140 Acoustic 25dB Special sizes and materials - galvanized and stainless steel, available on request. BS EN Security Pass Wind Speed With Open Cover 30 m/s 6 NOTE Copies of Taylor Woodrow Developments test reports for S-50T product available on request.

7 Ladder Access Shown with optional Bilco LadderUP Safety Post Type GS-50T TYPE GS-50T - Aluminium All the security and convenience of the Type S roof hatch with the added benefits of a skylight. GS Roof Hatches feature aluminium construction and virtually indestructible polycarbonate domes. Furnish and install where indicated on plans metal roof hatch. Length denotes hinge side. The roof hatch shall be single leaf. The roof hatch shall be pre-assembled from the manufacturer. Performance Cover shall be reinforced to support a minimum live load of Lifting Manufacturer shall provide compression spring operators characteristics: 195 kg/m 2. mechanisms: enclosed in telescopic tubes to provide smooth, easy, and Operation of the cover shall be smooth and easy with controlled controlled cover operation throughout the entire arc of opening operation throughout the entire arc of opening and closing. and closing. The upper tube shall be the outer tube to prevent accumulation of moisture, grit, and debris inside the lower tube Operation of the cover shall not be affected by temperature. assembly. The lower tube shall interlock with a flanged support Entire hatch shall be weathertight with fully welded corner joints shoe that is bolted to the curb assembly. on cover and curb. Hardware Heavy pintle hinges shall be provided Cover: Aluminium extrusion with built in drainage channel and clear Cover shall be equipped with a spring latch with interior and polycarbonate double skin dome. Cover shall have a heavy exterior turn handles extruded EPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top Shall be equipped with interior and exterior padlock hasps. surface of the curb. The latch strike shall be bolted to the curb assembly. Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb Cover shall automatically lock in the open position with a rigid shall be formed with a 114mm flange with 11mm holes hold open arm equipped with a 25mm diameter red vinyl grip provided for securing to the roof deck. The curb shall be handle to permit easy release for closing. equipped with an integral metal capflashing of the same gauge Compression spring tubes shall be an anti-corrosive composite and material as the curb, fully welded at the corners, that material and all other hardware shall be zinc plated and chromate features the Bil-Clip flashing system, including stamped tabs, sealed. Springs shall have an electrocoated acrylic finish for 153mm on centre, to be bent inward to hold single ply roofing corrosion resistance. [ For installation in highly corrosive membrane securely in place. environments or when prolonged exposure to hot water or steam Curb Shall be polyisocyanurate of 50mm thickness with a U-value of is anticipated, specify Type 316 stainless steel hardware ]. insulation: 0.47 W/m 2 K. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed within the insulation space. Finishes: Factory finish shall be mill finish aluminium. Options See page 24 STANDARD SIZES & WEIGHTS Type Size - clear internal dimensions Overall Dimensions Weight GS-50T 915mm x 760mm (H) 1143mm x 988mm 0 kg GS-50T CL 915mm x 760mm (H) 1143mm x 988mm 6 kg GSS-50T Special sizes on request 50 - Aluminium (H) - Hinge Side CL - Curb Liner Special sizes available on request. 7

8 Ship Stair Access Gasket (All Around) Cover Spring Latch with Inside-Outside Handles and Padlock Hasps Cover Liner 50mm Polyisocyanurate Insulation throughout cover Red Vinyl Grip Automatic Hold Open Arm and Cover Release Curb with integral Capflashing and Bilclip Combination Lock Strike and Padlock Hasp mm 187mm Lifting Mechanism with Reinforced Composite Tubes and Electrocoated Compression Springs 83mm 83mm 114mm 114mm Hinge 50mm Polyisocynurate Insulation around outside of curb Type NB-50T TYPE NB-50T - Aluminium Ideal for installations where frequent use may be expected. Permits easier movement of maintenance personnel, tools and equipment. 760mm Furnish and install where indicated on plans metal roof hatch. Length denotes hinged side. The roof hatch shall be single leaf. The roof hatch shall be pre-assembled from the manufacturer. Performance Cover shall be reinforced to support a minimum live load of Lifting Manufacturer shall provide compression spring operators characteristics: 195 kg/m 2 with a maximum deflection of 1/150th of the span or 97 kg/m 2 wind uplift. mechanisms: enclosed in telescopic tubes to provide smooth, easy, and controlled cover operation throughout the entire arc of opening and closing. The upper tube shall be the outer tube to prevent Operation of the cover shall be smooth and easy with controlled accumulation of moisture, grit, and debris inside the lower tube operation throughout the entire arc of opening and closing. assembly. The lower tube shall interlock with a flanged support Operation of the cover shall not be affected by temperature. shoe that is bolted to the curb assembly. Entire hatch shall be weathertight with fully welded corner joints on cover and curb. Hardware Heavy pintle hinges shall be provided Cover shall be equipped with a spring latch with interior and Cover: Cover insulation: Curb: Curb 2.3mm aluminium with a 0mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb. Shall be polyisocyanurate of 50mm thickness with a U-value of 0.47 W/m 2 K. Insulation shall be fully covered and protected by an aluminium liner. Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place. Shall be polyisocyanurate of 50mm thickness with a U-value of exterior turn handles Shall be equipped with interior and exterior padlock hasps. The latch strike shall be bolted to the curb assembly. Cover shall automatically lock in the open position with a rigid hold open arm equipped with a 25mm diameter red vinyl grip handle to permit easy release for closing. Compression spring tubes shall be an anti-corrosive composite material and all other hardware shall be zinc plated and chromate sealed. Springs shall have an electrocoated acrylic finish for corrosion resistance. [ For installation in highly corrosive environments or when prolonged exposure to hot water or steam is anticipated, specify Type 316 stainless steel hardware ]. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed within the insulation space. insulation: 0.47 W/m 2 K. Finishes: Factory finish shall be mill finish aluminium. STANDARD SIZES & WEIGHTS Options See page 24 Type Size - clear internal dimensions Overall Dimensions Weight Performance NB-50T 760mm x 1370mm (H) 988mm x 1598mm 76 kg BS EN 12207:2000 Air Permeability 4.83 m3/hour/m2 at 600 Pa NB-50T CL 760mm x 1370mm (H) 988mm x 1598mm 84 kg BS EN 12208:2000 Water Tightness Class 9A 50 - Aluminium (H) - Hinge Side CL - Curb Liner BS EN 122:2000 Wind Resistance Class E2400 BS EN Snow Load 1200Pa for 1 hour Special sizes and materials - galvanized and stainless steel, available on request. BS 8200 Impact Resistance Pass BS EN ISO 140 Acoustic 25dB BS EN Security Pass Wind Speed With Open Cover 30 m/s 8 NOTE Copies of Taylor Woodrow Developments test reports for S-50T product available on request.

9 Gasket (All Around) Cover Service Stair Access Spring Latch with Inside-Outside Handles and PAdlock Hasps Two Point Lock Enclosure, Same Material as cover Cover Liner Red Vinyl Grip 50mm Polyisocyanurate Insulation throughout cover Automatic Hold Open Arm and Cover Release Curb with integral Capflashing and Bilclip Lock Strike mm 187mm Padlock Hasp Lifting Mechanism with Reinforced Composite Tubes and Electrocoated Compression Springs Hinge 50mm Polyisocyanurate Insulation around outside of curb Type L-50T 83mm 114mm 760mm 83mm 114mm Type L-50T Type SSY-50T TYPE L-50T & SSY-50T - Aluminium For where frequent use may be expected. Permits easier movement of maintenance personnel, tools and equipment from a full size stairway. Furnish and install where indicated on plans metal roof hatch. Length denotes hinged side. These roof hatches shall be single leaf. The roof hatch shall be pre-assembled from the manufacturer. Performance Cover shall be reinforced to support a minimum live load of Lifting Manufacturer shall provide compression spring operators characteristics: 195 kg/m 2 with a maximum deflection of 1/150th of the span or mechanisms: enclosed in telescopic tubes to provide, smooth, easy, and 97 kg/m 2 wind uplift. controlled cover operation throughout the entire arc of opening Operation of the cover shall be smooth and easy with controlled and closing. The upper tube shall be the outer tube to prevent operation throughout the entire arc of opening and closing. accumulation of moisture, grit, and debris inside the lower tube assembly. The lower tube shall interlock with a flanged support Operation of the cover shall not be affected by temperature. shoe that is bolted to the curb assembly. Cover: Entire hatch shall be weathertight with fully welded corner joints Hardware Heavy pintle hinges shall be provided on cover and curb. Cover fitted with enclosed two point spring latch with interior and 2.3mm aluminium with a 0mm beaded flange with formed exterior turn handles reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket which is bonded to the cover interior to ensure a Shall be equipped with interior and exterior padlock hasps. continuous seal when compressed to the top surface of the curb. The latch strike shall be bolted to the curb assembly. Cover Shall be polyisocyanurate of 50mm thickness with a U-value of Cover shall automatically lock in the open position with a rigid insulation: 0.47 W/m 2 K. Insulation shall be fully covered and protected by hold open arm equipped with a 25mm diameter red vinyl grip an aluminium liner. handle to permit easy release for closing. Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb Compression spring tubes shall be an anti-corrosive composite shall be formed with a 114mm flange with 11mm holes material and all other hardware shall be zinc plated and chromate provided for securing to the roof deck. The curb shall be sealed. Springs shall have an electrocoated acrylic finish for equipped with an integral metal capflashing of the same gauge corrosion resistance. [ For installation in highly corrosive and material as the curb, fully welded at the corners, that environments or when prolonged exposure to hot water or steam features the Bil-Clip flashing system, including stamped tabs, is anticipated, specify Type 316 stainless steel hardware ]. 153mm on centre, to be bent inward to hold single ply roofing Cover hardware shall be bolted into heavy gauge channel membrane securely in place. reinforcing welded to the underside of the cover and concealed Curb Shall be polyisocyanurate of 50mm thickness with a U-value of within the insulation space. insulation: 0.47 W/m 2 K. Finishes: Factory finish shall be mill finish aluminium. STANDARD SIZES & WEIGHTS Options See page 24 Type Size - clear internal dimensions Overall Dimensions Weight Performance L-50T 760mm x 2440mm (H) 988mm x 2668mm 130 kg. BS EN 12207:2000 Air Permeability 4.83 m3/hour/m2 at 600 Pa L-50T CL 760mm x 2440mm (H) 988mm x 2668mm 143 kg. BS EN 12208:2000 Water Tightness Class 9A SSY-50T 760mm x 3360mm (H) 988mm x 3588mm 160 kg. BS EN 122:2000 Wind Resistance Class E2400 SSY-50T CL 760mm x 3360mm (H) 988mm x 3588mm 176 kg. BS EN Snow Load 1200Pa for 1 hour 50 - Aluminium (H) - Hinge Side CL - Curb Liner BS 8200 Impact Resistance Pass BS EN ISO 140 Acoustic 25dB Special sizes and materials - galvanized and stainless steel, available on request. BS EN Security Pass Wind Speed With Open Cover 30 m/s NOTE Copies of Taylor Woodrow Developments test reports for S-50T product available on request. 9

10 Refurbishment Gasket (All Around) Cover Lifting Mechanism with Reinforced Composite Tubes and Electrocoated Compression Springs Spring Latch with Inside-Outside Handles and Padlock Hasps (Handles to be installed on site by customer) Cover Liner 50mm Polyisocyanurate Insulation throughout cover Red Vinyl Grip Automatic Hold Open Arm and Cover Release Combination Lock Strike and Padlock Hasp 87 38mm 140mm 67mm Anchor Clips Hinge 25mm Rigid Fiberboard Insulation around outside of curb 78mm 915mm 78mm Type S-50VMT - Optional anodized finish shown TYPE VERSAMOUNT The VersaMount is ideal for refurbishment projects where a weather proof upstand is existing. Easy to fit the anchor clip system and versatile frame design helps complete the job efficiently. Furnish and install where indicated on plans metal roof hatch. Length denotes hinge side. The roof hatch shall be single leaf. The roof hatch shall be pre-assembled from the manufacturer. Performance Cover shall be reinforced to support a minimum live load of Lifting Manufacturer shall provide compression spring operators characteristics: 195 kg/m 2 with a maximum deflection of 1/150th of the span or 97 kg/m 2 wind uplift. mechanisms: enclosed in telescopic tubes to provide smooth, easy, and controlled cover operation throughout the entire arc of opening and closing. The upper tube shall be the outer tube to prevent Operation of the cover shall be smooth and easy with controlled accumulation of moisture, grit, and debris inside the lower tube operation throughout the entire arc of opening and closing. assembly. The lower tube shall interlock with a flanged support Operation of the cover shall not be affected by temperature. shoe that is bolted to the curb assembly. Entire hatch shall be weathertight with fully welded corner joints on cover and curb. Hardware Heavy pintle hinges shall be provided Cover shall be equipped with a spring latch with interior and Cover: Shall be 2.3mm aluminium with a 0mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb. exterior turn handles Shall be equipped with interior and exterior padlock hasps. The latch strike shall be bolted to the curb assembly. Cover shall automatically lock in the open position with a rigid Cover Shall be polyisocyanurate of 50mm thickness with a U-value of hold open arm equipped with a 25mm diameter red vinyl grip insulation: 0.47 W/m 2 K. Insulation shall be fully covered and protected by an aluminium liner. handle to permit easy release for closing. Compression spring tubes shall be an anti-corrosive composite Curb: Shall be 2mm in height and of 2.3mm aluminium. The curb shall be formed with a 67mm flange and a 38mm apron, fully welded at corners. Stainless Steel anchor clips are included. Bilco recommend maximum upstand width is 65mm material and all other hardware shall be zinc plated and chromate sealed. Springs shall have an electrocoated acrylic finish for corrosion resistance. [ For installation in highly corrosive environments or when prolonged exposure to hot water or steam Curb Shall be polyisocyanurate of 25mm thickness with a U-value of is anticipated, specify Type 316 stainless steel hardware ]. insulation: 0.87 W/m 2 K. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed within the insulation space. Finishes: Factory finish shall be mill finish aluminium. STANDARD SIZES & WEIGHTS Options See page 24 Type Size - clear internal dimensions Overall Dimensions Weight Performance S-50VMT 915mm x 760mm (H) 71mm x 916mm 50 kg BS EN 12207:2000 Air Permeability 4.83 m3/hour/m2 at 600 Pa 50 - Aluminium (H) - Hinge Side BS EN 12208:2000 Water Tightness Class 9A Special size not available BS EN 122:2000 Wind Resistance Class E2400 BS EN Snow Load 1200Pa for 1 hour BS 8200 Impact Resistance Pass BS EN ISO 140 Acoustic 25dB BS EN Security Pass Wind Speed With Open Cover 30 m/s NOTE Copies of Taylor Woodrow Developments test reports for S-50T product available on request.

11 Security Access Type S-50CT - Optional Tnemec finish shown TYPE SECURITY SERIES Constructed of heavier gauge materials for high security applications such as prisons, banks, embassies, and pharmaceutical buildings. A variety of lock options as well as security glazing is also available. Furnish and install where indicated on plans metal Security Series roof hatch. Length denotes hinge side. The roof hatch shall be single leaf. The roof hatch shall be pre-assembled from the manufacturer. Performance Cover shall be reinforced to support a minimum live load of characteristics: 195 kg/m 2 with a maximum deflection of 1/150th of the span or 97 kg/m 2 wind uplift. Operation of the cover shall be smooth and easy with controlled operation throughout the entire arc of opening and closing. Operation of the cover shall not be affected by temperature. Entire hatch shall be weathertight with fully welded corner joints on cover and curb. Cover: Shall be 5mm aluminium with a 0mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb. Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m 2 K. Insulation shall be fully covered and protected by an aluminium liner. Curb: Shall be 305mm in height and of 5mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners. Curb Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m 2 K. STANDARD SIZES & WEIGHTS Type Size - clear Overall Open internal dimensions Dimensions Weight angle S-50CT 915mm x760mm 1143mm x 988mm 68 kg 70 E-50CT 915mm x 915mm 1143mm x 1143mm 80 kg 70 NB-50CT 760mm x 1370mm 988mm x 1598mm 95 kg 90 SS-50CT Special sizes on request 50 - Aluminium (H) - Hinge Side CL - Curb Liner Special sizes and materials - galvanized and stainless steel, available on request. Lifting Manufacturer shall provide compression spring operators mechanisms: enclosed in telescopic tubes to provide smooth, easy, and controlled cover operation throughout the entire arc of opening and closing. The upper tube shall be the outer tube to prevent accumulation of moisture, grit, and debris inside the lower tube assembly. The lower tube shall interlock with a flanged support shoe that is bolted to the curb assembly. Hardware Heavy pintle hinges shall be provided Cover shall be equipped with a spring latch with interior and exterior turn handles. Shall be equipped with interior and exterior padlock hasps. The latch strike shall be bolted to the curb assembly. Cover shall automatically lock in the open position with a rigid hold open arm equipped with a 25mm diameter red vinyl grip handle to permit easy release for closing. Springs shall have an electrocoated acrylic finish for corrosion resistance. All other hardware shall be zinc plated and chromate sealed [ For installation in highly corrosive environments or when prolonged exposure to hot water or steam is anticipated, specify Type 316 stainless steel hardware ]. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed within the insulation space. Finishes: Factory finish shall be mill finish aluminium. Options See page 24 Performance BS EN 12207:2000 Air Permeability 4.83 m3/hour/m2 at 600 Pa BS EN 12208:2000 Water Tightness Class 9A BS EN 122:2000 Wind Resistance Class E2400 BS EN Snow Load 1200Pa for 1 hour BS 8200 Impact Resistance Pass BS EN ISO 140 Acoustic 25dB BS EN Security Pass Wind Speed With Open Cover 30 m/s NOTE Copies of Taylor Woodrow Developments test reports for S-50T product available on request. 11

12 Plant Access Type F-50T standard hatch TYPE F-50T, TYPE SS-50T & TYPE D-50T There are a wide range of options for plant access making it easy to install or remove equipment from a building. D-50T Furnish and install where indicated on plans metal roof hatch. These roof hatches shall be single leaf and/or double leaf and shall be pre-assembled from the manufacturer. Performance Cover shall be reinforced to support a minimum live load of characteristics: 195 kg/m 2 with a maximum deflection of 1/150th of the span or 97 kg/m 2 wind uplift. Operation of the cover shall be smooth and easy with controlled operation throughout the entire arc of opening and closing. Operation of the cover shall not be affected by temperature. Entire hatch shall be weathertight with fully welded corner joints on cover and curb. Cover: 2.3mm aluminium with a 0mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket which is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb. Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m 2 K. Insulation shall be fully covered and protected by an aluminium liner. Curb: Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place. Curb Shall be polyisocyanurate of 50mm thickness with a U-value of insulation: 0.47 W/m 2 K. STANDARD SIZES & WEIGHTS Type Size - clear internal dimensions Overall Dimensions Weight F-50T 1220mm x 1220mm 1448mm x 1448mm 113 kg F-50T CL 1220mm x 1220mm 1448mm x 1448mm 123 kg D-50T Special sizes on request SS-50T Special sizes on request Lifting Manufacturer shall provide compression spring operators mechanisms: enclosed in telescopic tubes to provide smooth, easy, and controlled cover operation throughout the entire arc of opening and closing. The upper tube shall be the outer tube to prevent accumulation of moisture, grit, and debris inside the lower tube assembly. The lower tube shall interlock with a flanged support shoe that is bolted to the curb assembly. Hardware Heavy pintle hinges shall be provided Cover shall be equipped with a spring latch with interior and exterior turn handles. Double leaf and single leaf covers over 2133mm have a 2-point spring latch system Shall be equipped with interior and exterior padlock hasps. The latch strike shall be bolted to the curb assembly. Cover shall automatically lock in the open position with a rigid hold open arm equipped with a 25mm diameter red vinyl grip handle to permit easy release for closing. Compression spring tubes shall be an anti-corrosive composite material and all other hardware shall be zinc plated and chromate sealed. Springs shall have an electrocoated acrylic finish for corrosion resistance. [ For installation in highly corrosive environments or when prolonged exposure to hot water or steam is anticipated, specify Type 316 stainless steel hardware ]. Cover hardware shall be bolted into heavy gauge channel reinforcing welded to the underside of the cover and concealed within the insulation space. Finishes: Factory finish shall be mill finish aluminium. Options See page Aluminium CL - Curb Liner Special sizes available on request Type SS - Single Leaf Type D - Double Leaf Type D double leaf roof hatch for larger openings, over 2135mm in width. 12

13 Bil-Guard Hatch Rail System A + 368mm nom A Top of rail to be set 7cm above the roof surface or deck Hinge side B B + 368mm nom Isometric View Type RL-S shown on Type S roof hatch Plan View Shown without hatch cover A = hatch opening width B = hatch opening length Self-closing gate hinge ensures continuous protection Pivoting mounting sleeve for installation flexibility Quickmount bracket for fast, secure attachment ROOF SAFETY SYSTEM Bil-Guard is a fixed railing system that provides a permanent means of fall protection for hatch and smoke vent openings. It can also help provide continuous protection especially where mansafe systems have been installed on the roof area. Bil-Guard features an innovative attachment system that does not penetrate the roofing membrane and on standard hatches pre-drilled holes in the capflashing accept the mounting brackets. Bil-Guard can be installed quickly and easily using basic tools. Posts and rails are pultruded from a fire retardant, fibreglass-reinforced polymer (FRP). FRP material has a moulded-in, high visibility, safety yellow colour and is treated with a UV inhibitor. Mounting brackets are fabricated from 6mm thick hot dip galvanized steel. Gate hinges and post guides are constructed of T5 aluminium and torsion rod is Type 302 stainless steel. All fasteners are Type 316 stainless steel. Manufacturer shall provide a 25-year warranty against defects in material and workmanship. STANDARD SIZES & WEIGHTS Type Size - Overall Weight Hatch clear internal dimensions Dimensions type RL-S 915mm x 760mm (H) 1285mm x 1130mm 24 kg S RL-E 915mm x 915mm 1285mm x 1285mm 24 kg E RL-F 1220mm x 1220mm 1590mm x 1590mm 28 kg F RL-NB 760mm (H) x 1370mm 1130mm x 1815mm 28 kg NB RL-L 760mm (H) x 2440mm 1130mm x 2885mm 35 kg L (H) - Hinge Side Special sizes can also be manufactured Key Features & Benefits Corrosion resistant - 25-year warranty High visibility safety yellow colour Non-penetrating attachment Pivoting mounting sleeve for installation flexibility Standard self-closing gate feature Available in a variety of sizes Fits all Bilco roof hatches Easily installed on new or existing hatches and smoke vents 13

14 Smoke Vents 95% of all fire Bilco smoke vents are designed to satisfy Building Regulations and meet Approved Document B, BS 9999 (which supercedes BS5588) and European Standards enshrined in EN 121. For the EN 121 key areas of the regulations are that the covers must reach the fire open position within 60 seconds and that single covers open to 140 to ensure there are no negative wind coefficients ie wind blowing smoke back into the building. Bilco smoke vents are also compatible with other guidance and codes of practices, for example those issued by the British Research Establishment such as BRE Entire vent shall be weathertight with fully welded corner joints on cover and curb. A single linear actuator mounted on a pivoting carriage capable of opening the cover to the fire open position of 140 degrees within 60 seconds. Fully insulated cover and curb. 50mm thick faced rigid polyisocyanurate thermal insulation board. U value of 0.47Wm 2 /K The new range of Bilco smoke vents have all been thermally enhanced and a higher performance gasket has been introduced. Approved Document B - The diagram above depicts a typical stand alone system which is installed in a 4 storey building stairwell with the ventilator positioned at the head of the stair and control systems within the stairwell. Flange with pre-drilled fixing points for easy installation Typical Applications High-Rise Housing Offices and Commercial Buildings Aircraft Hangars Auditoria Concert Halls and Theatres Convention Centres Gymnasiums Manufacturing Plants Retail Centres Schools Hospitals Distribution Depots Warehouses Key Features & Benefits Increased evacuation time and decreased risk of smoke inhalation and damage Enhanced visibility to allow firefighters to quickly locate the fire Protection against secondary ignitions and lateral fire spread Exhausting of noxious and potentially explosive fumes Structure protection from damaging heat Reduce damage to building contents Can be used for access and comfort ventilation Type EEW-50REM Typically positioned at the head of a stairwell or smoke shaft. The vent will act as a chimney clearing the building of heat and smoke. 14

15 related deaths result from smoke inhalation Newly designed closed cell EPDM sponge gasket, helps meet Building Regulations air leakage targets by providing a better seal of the cover to the curb, ensuring complete weather-tightness. Enclosed hinge assembly Curb mounted junction box with terminal block enclosed for power cable connection. Standard product - clear vent areas of 1m 2 and 1.5m 2 Thermal insulation board Capflashing Meets BS EN 12207Curb Membrane (adhered to itself) Bilclip flashing system Bilclip Insulated curb with cap flashing and Bil-Clip flashing system. Installation is simply a matter of placing the vent over the roof opening and securing it to the roof deck through the holes provided in the base flange. The integral capflashing readily accepts roofing felts reducing installation time and costs. 15

16 Smoke Vents - Solid Covers Type EEW-50REM TYPE REM SMOKE VENTS - Single Leaf 140 Electric actuation for remote opening & closing. The smoke vent shall be single leaf and provide 1m 2 or 1.5m 2 clear vent area. The smoke vent shall be pre-assembled from the manufacturer. Performance Cover shall be reinforced to support a minimum live load of characteristics 195 kg/m 2 with a maximum deflection of 1/150th of the span or 97 kg/m 2 wind uplift. Operation of the cover shall be through a 24VDC battery backed control system that will open the cover to the fire open position within 60 seconds and be capable of closing the cover. Operation of the cover shall not be affected by temperature. Entire vent shall be weathertight with fully welded corner joints on cover and curb. Cover Shall be 2.3mm aluminium with a 0mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket that is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb. Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation 0.47 W/m 2 K. Insulation shall be fully covered and protected by an aluminium liner. Curb Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place. Curb insulation Shall be polyisocyanurate of 50mm thickness with a U-value of 0.47 W/m 2 K. Operating A single linear actuator mounted on a pivoting carriage capable of mechanism opening the cover to the fire open position of 140 degrees. (Note roof obstructions should be considered alternative products opening to 90 ) Hardware Heavy pintle hinges shall be provided. Curb mounted junction box with a terminal block enclosed for power cable connection. Finishes Factory finish shall be mill finish aluminium. Controls See page 22 Options See page 24 STANDARD SIZES & WEIGHTS - Single Leaf 140 Type Size - clear internal dimensions Overall Dimensions Weight Clear Vent Area ENB-50REM 760mm x 1620mm (H) 988mm x 1848mm 118 kg 1m 2 ENB-50REM CL 760mm x 1620mm (H) 988mm x 1848mm 127 kg 1m 2 EEW-50REM 00mm x 1250mm (H) 1228mm x 1478mm 120 kg 1m 2 EEW-50REM CL 00mm x 1250mm (H) 1228mm x 1478mm 129 kg 1m 2 EFW-50REM 1250mm x 1500mm (H) 1478mm x 1728mm 143 kg 1.5m 2 EFW-50REM CL 1250mm x 1500mm (H) 1478mm x 1728mm 154 kg 1.5m 2 EHW-50REM 00mm x 1750mm (H) 1228mm x 1978mm 195 kg 1.5m 2 EHW-50REM CL 00mm x 1750mm (H) 1228mm x 1978mm 206 kg 1.5m 2 ESS-50REM Min 760mm x Consult UK Office for sizing 1.5m 2 max ESS-50REM CL Min 760mm x Consult UK Office for sizing 1.5m 2 max 50 - Aluminium (H) - Hinge Side CL - Curb Liner 16

17 Smoke Vents - Solid Covers TYPE REM SMOKE VENTS - Single Leaf 90 Electric actuation for remote opening & closing. Type UEW-50REM The smoke vent shall be single leaf and shall be pre-assembled from the manufacturer. Performance Cover shall be reinforced to support a minimum live load of characteristics 195 kg/m 2 with a maximum deflection of 1/150th of the span or 97 kg/m 2 wind uplift. Operation of the cover shall be through a 24VDC battery backed control system that will open the cover to the fire open position within 60 seconds and be capable of closing the cover. Operation of the cover shall not be affected by temperature. Entire vent shall be weathertight with fully welded corner joints on cover and curb. Cover Shall be 2.3mm aluminium with a 0mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket that is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb. Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation 0.47 W/m 2 K. Insulation shall be fully covered and protected by an aluminium liner. Curb Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place. Curb insulation Shall be polyisocyanurate of 50mm thickness with a U-value of 0.47 W/m 2 K. Operating Two 24VDC linear actuators capable of opening the cover to the mechanism fire open position of 90 degrees. (Note alternative products opening to 140 ) Hardware Heavy pintle hinges shall be provided Curb mounted junction box with a terminal block enclosed for power cable connection. Finishes Factory finish shall be mill finish aluminium. Controls See page 22 Options See page 24 STANDARD SIZES & WEIGHTS - Single Leaf 90 Type Size - clear internal dimensions Overall Dimensions Weight Clear Vent Area UNB-50REM 760mm x 1620mm (H) 988mm x 1848mm 113 kg 1.23m 2 UNB-50REM CL 760mm x 1620mm (H) 988mm x 1848mm 122 kg 1.23m 2 UEW-50REM 00mm x 1250mm (H) 1228mm x 1478mm 115 kg 1,25m 2 UEW-50REM CL 00mm x 1250mm (H) 1228mm x 1478mm 124 kg 1,25m 2 UFW-50REM 1250mm x 1500mm (H) 1478mm x 1728mm 138 kg 1.88m 2 UFW-50REM CL 1250mm x 1500mm (H) 1478mm x 1728mm 149 kg 1.88m 2 UHW-50REM 00mm x 1750mm (H) 1228mm x 1978mm 190 kg 1.75m 2 UHW-50REM CL 00mm x 1750mm (H) 1228mm x 1978mm 201 kg 1.75m 2 USS-50REM Min 760mm x Consult UK Office for sizing * USS-50REM CL Min 760mm x Consult UK Office for sizing * 50 - Aluminium (H) - Hinge Side CL - Curb Liner *Springs included on larger sizes 17

18 Smoke Vent - Translucent Type UGEW-50REM TYPE UGEW-50REM - Single Leaf 90 Electric actuation for remote opening & closing, the UGEW-50REM offers a natural daylight option with polycarbonate cover to maximise light transmission whilst minimising solar heat gain. The smoke vent shall be single leaf and provide 1.0m 2 clear vent area. The smoke vent shall be pre-assembled from the manufacturer. Performance Cover shall be reinforced to support a minimum live load of characteristics 195 kg/m 2 with a maximum deflection of 1/150th of the span or 97 kg/m 2 wind uplift. Operation of the cover shall be through a 24VDC battery backed control system that will open the cover to the fire open position within 60 seconds and be capable of closing the cover. Operation of the cover shall not be affected by temperature. Entire vent shall be weathertight with fully welded corner joints on cover and curb. Cover Aluminium extrusion with built in drainage channel and clear polycarbonate double skin dome. Cover shall have a heavy extruded EPDM rubber gasket that is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb. Curb Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place. Curb insulation Shall be polyisocyanurate of 50mm thickness with a U-value of 0.47 W/m 2 K. Operating Two 24VDC linear actuators capable of opening the cover to the mechanism fire open position of 90. Hardware Heavy pintle hinges shall be provided. Curb mounted junction box with a terminal block enclosed for power cable connection. Finishes Factory finish shall be mill finish aluminium. Controls See page 22 Options See page 24 STANDARD SIZES & WEIGHTS - Translucent - Single Leaf 90 Type Size - clear internal dimensions Overall Dimensions Weight Clear Vent Area UGEW-50REM 00mm x 00mm 1228mm x 1228mm 111 kg 1.m 2 UGEW-50REM CL 00mm x 00mm 1228mm x 1228mm 119 kg 1.m 2 UGSS-50REM Consult UK Office for sizing UGSS-50REM CL Consult UK Office for sizing CL - Curb Liner Special sizes available on request 18

19 Smoke Vent - Translucent Type UFW-LVREM REM LUMIVENT - Double Leaf 90 Electric actuation for remote opening & closing, the Lumivent provides the security and value of an automatic smoke vent with the added benefits of a skylight. Product provides natural daylight and energy efficiency while minimizing solar heat gain. Product features aluminium construction and a virtually indestructible polycarbonate cover. The smoke vent shall be double leaf and provide 1.5m 2 clear vent area. The smoke vent shall be pre-assembled from the manufacturer. Performance Covers shall be reinforced to support a minimum live load of characteristics 195 kg/m 2 with a maximum deflection of 1/150th of the span or 97 kg/m 2 wind uplift. Operation of the covers shall be through a 24VDC battery backed control system that will open the covers to the fire open position within 60 seconds and be capable of closing the covers. Operation of the covers shall not be affected by temperature. Entire vent shall be weathertight with fully welded corner joints on covers and curb. Covers Shall be constructed with a translucent multi-wall polycarbonate sheet framed with rigid extruded aluminium and coated for UV resistance. Covers shall slope 4:12. Curb Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip flashing system, including stamped tabs, 153mm on centre, to be bent inward to hold single ply roofing membrane securely in place. There shall be a fixed central drip channel through the centre section of the curb. Curb insulation Shall be polyisocyanurate of 50mm thickness with a U-value of 0.47 W/m 2 K. Operating Two 24VDC linear actuators per cover (four actuators total) mechanism capable of opening the cover to the fire open position of 90. Hardware Heavy pintle hinges shall be provided Curb mounted junction box (2 no.) with terminal blocks enclosed for power cable connection. Finishes Factory finish shall be mill finish aluminium. Controls See page 22 Options See page 24 STANDARD SIZES & WEIGHTS - Translucent - Double Leaf 90 Type Size - clear internal dimensions Overall Dimensions Weight Clear Vent Area UFW-LVREM 1250mm x 1250mm 1478mm x 1478mm 113 kg 1.5m 2 UFW-LVREM CL 1250mm x 1250mm 1478mm x 1478mm 123 kg 1.5m 2 CL - Curb Liner Special sizes available on request Features a multi-wall polycarbonate cover design that resists UV degradation and offers superior insulation performance compared to traditional domes 19

20 Smoke Vent - Specials Type UD-50REM TYPE UD-50 REM - Double Leaf 90 REM smoke ventilator, electric actuation for remote opening & closing, features aluminium construction and can be fabricated to just about any size to meet your unique venting requirements. The smoke vent shall be double leaf and provide m 2 clear vent area. The smoke vent shall be pre-assembled from the manufacturer. Performance Covers shall be reinforced to support a minimum live load of characteristics 195 kg/m 2 with a maximum deflection of 1/150th of the span or 97 kg/m 2 wind uplift. Operation of the covers shall be through a 24VDC battery backed control system that will open the covers to the fire open position within 60 seconds and be capable of closing the covers. Operation of the covers shall not be affected by temperature. Entire vent shall be weathertight with fully welded corner joints on covers and curb. Covers Shall be 2.3mm aluminium with a 0mm beaded flange with formed reinforcing members. Cover shall have a heavy extruded EPDM rubber gasket that is bonded to the cover interior to ensure a continuous seal when compressed to the top surface of the curb. Cover Shall be polyisocyanurate of 50mm thickness with a U-value of insulation 0.47 W/m 2 K. Insulation shall be fully covered and protected by an aluminium liner. Curb Shall be 305mm in height and of 2.3mm aluminium. The curb shall be formed with a 114mm flange with 11mm holes provided for securing to the roof deck. The curb shall be equipped with an integral metal capflashing of the same gauge and material as the curb, fully welded at the corners, that features the Bil-Clip flashing system, including stamped tabs, 153mm on center, to be bent inward to hold single ply roofing membrane securely in place. There shall be a fixed central drip channel through the centre section of the curb. Curb insulation Shall be polyisocyanurate of 50mm thickness with a U-value of 0.47 W/m 2 K. Operating Two 24VDC linear actuators per cover (four actuators total) mechanism capable of opening the cover to the fire open position of 90 degrees. Hardware Heavy pintle hinges shall be provided. Curb mounted junction box (2 no.) with terminal blocks enclosed for power cable connection. Finishes Factory finish shall be mill finish aluminium. Controls See page 22 Options See page 24 STANDARD SIZES & WEIGHTS - Double Leaf 90 Type Size - Overall Weight Clear clear internal dimensions Dimensions Vent Area UD-50REM Consult UK Office *Springs included on larger sizes 20

21 Smoke Vent - Acoustic Type ACDSH TYPE ACDSH - Double Leaf 90 Mechanically operated smoke vents. Ideal for concert halls, theatres, casinos, sporting arenas and other applications. Vent covers are oversprung and open automatically when heat melts a 74 C fusible link. Available in a number of standard FM-approved sizes, these vents are designed to guard against noise intrusion and at the same time provide the security of dependable automatic venting in the event of a fire. Vents carry an STC-45 and OITC-37 sound rating. Material Covers Curb Gasket Cover and frame are 2mm G-90 paint bond galvanized steel Designed with upward and downward opening covers to achieve acoustical sound rating. Breakformed, hollow-metal design with 51mm concealed fibreglass insulation, 2mm beaded, overlapping flange, fully welded at corners, and internally reinforced for 195 kg/m 2 live load 406mm in height with integral capflashing, 25mm fibreboard insulation, fully welded at corners, and 89mm mounting flange with 11mm holes provided for securing frame to the roof deck Extruded EPDM rubber gasket permanently adhered to the upward opening covers. Downward opening covers utilize a permanently adhered neoprene foam gasket. Hinges Upward opening: Heavy-duty pintle hinges with mm Type 316 stainless steel hinge pins. Downward opening: Continuous piano hinge Latch Positive hold/release mechanism controlled by a single UL-listed 74 C fusible link with a separate latching point for all covers. Designed to hold the covers closed against a 438 kg/m 2 uplift force. Provided with interior and exterior pull release cables to manually open vent covers. (24v DC latching mechanism can be specified for connection to a smoke alarm system.) Operation Compression springs enclosed in telescopic tubes open covers automatically against a 49 kg/m 2 snow/wind load when released. Automatic hold-open arms lock each cover in the full open position. Each cover is supplied with a shock absorber to ensure a controlled rate of opening. Performance FM-approved. STC-45 and OITC-37 sound rating. Comply with Ratings UL 790 Class A (burning brand test). Finish Alkyd base red oxide primer Hardware Engineered composite compression spring tubes. Steel compression springs with electrocoated acrylic finish. All other hardware is zinc plated/chromate sealed Controls See page 22 Options See page 24 STANDARD SIZES & WEIGHTS Type Size - Overall Weight clear internal dimensions Dimensions ACDSH mm x 1220mm 1398mm x 1398mm 363 kg ACDSH mm x 1830mm (H) 1398mm x 2008mm 426 kg ACDSH mm x 2290mm (H) 1398mm x 2468mm 533 kg ACDSH mm x 2440mm (H) 1398mm x 2618mm 558 kg ACDSH mm x 1520mm 1698mm x 1698mm 528 kg ACDSH mm x 2440mm (H) 1698mm x 2618mm 701 kg ACDSH66144* 1680mm x 3660mm (H) 1858mm x 3838mm 32 kg ACDSH mm x 1830mm 2008mm x 2008mm 685 kg (H) - Hinge Side *This size has four covers 21

22 Control Options Bilco controls and accessories are designed to work effectively with the range of natural smoke ventilators and roof hatches. The OS2 control unit can be a stand-alone management system - in it's own right, or it can be integrated into a fully networked fire alarm or BMS system. In the event of a fire, if the mains electrical supply to the building is cut the OS2 offers a failsafe option as it incorporates a backup battery system to ensure the natural smoke vents will still open. Special control units for unique applications can also be manufactured. Other control accessories are available to independently open and close access equipment in non-emergency situations for example for roof inspection and maintenance, as well as making it easier to utilize the roof space for plant and recreational use. There are a number of security accessories available and options for comfort ventilation. Indeed, with the growing demand for buildings to be sustainable, energy efficient and environmentally friendly, a building that can ventilate solar heat gains in the summer and retain heat in the winter is vitally important. Controls such as thermostats and rain sensors can for example, moderate a building 'overheating' during the day, as well as providing additional revenue saving benefits in terms of reducing the use of energy hungry H&V equipment. MCP Designed to allow the Fire Officer to manually overide the smoke control system through a user friendly interface. Design includes an open button and a close/reset button, which are accessed by lifting the clear front door. The unit is equipped with a tamper evident tie. 1RPREM-02 Typical smoke vent SMOKE VENTS Junction box Fitted as standard to all smoke vents ready for wiring. Meets IP55 Control panel The OS2 control unit can be a standalone management system or it can be integrated into a fully networked fire alarm or BMS system. OS2 accepts a supply of 230V AC 50/60 Hz from a 3A fused unswitched spur and has a current rating of 2A. Output is 24V DC 2-Channels. Combined output must not exceed 8A. Intermittent - 6mins in any 1 hour; 5A continuous. The backup battery module comprises 2x12V DC which has 2.2Ah sealed lead-acid batteries. 1RPREM-09 OPEN CLOSE / RESET Control panel kit Comprisescontrol panel, fireman s switch (MCP) and smoke detector 1RPREM-01 SMOKE VENTS OPEN CLOSE / RESET 22

23 The heart of the system MCP With break glass 1RPREM-21 Smoke detector Non-latching & optical, with flashing LED 1RPREM-03 Open/close smoke vent switch. Stainless steel face plate, designed to be used as a keyed or paddle switch 1RPREM-08 (keyed) 1RPREM-08A (paddle) Open/close switch. amp durable white plastic sprung switch. 1RPREM- Weather proof open/close switch. Made from steel the keyed switch is sprung to centre and cannot be operated with out the security key. 1RPREM-11 Auto/manual control switch. To be used in conjunction with thermostat and/or rain sensor. Stainless steel face plate, designed to be used as a 2 position switch 1RPREM-07 Thermostat Industry standard to 30 c range 1RPREM-04 Rain sensor robust & cost effective 1RPREM-15 BMS External Connections (eg. alarm & ventilation systems) Network in Network out 230V Fused Spur Volt free contact from fire alarm 23

24 Options Roof Access Hatches & Automatic Smoke Vents CURB OPTIONS Curb Liner Metal insulation liner of the same materials as the curb and capflashing. Ideal for applications where aggressive adhesives or torch applied weather proofing systems are being used. Fully Enclosed Curb Insulation liner of the same materials as the curb, which replaces the capflashing. Used with hot applied systems or where the hatch is welded directly to the roofing panel. Flanged Apron Design A top-hat design which makes installation very easy and virtually eliminates the problems of water proofing on the roof. Ideal for situations where the roofing material is applied prior to the hatch or vent arriving on-site. Built-in Louvers Useful for reducing condensation in buildings or for air displacement in lift shafts. PAINT FINISHES Common options include polyester powder coating, anodizing aluminium as well as Tnemec finishes. Stock items can be polyester powder coated to any standard RAL or BS colour within 2-3 weeks. 24

25 Options SECURITY OPTIONS Keyed Cylinder Locks Provide keyed exterior access and are available with either keyed or turn knob interior access. Ideal security enhancement for many applications. For added security and weathertightness, the lock cylinder is accessed from the exterior through a gasketed, threaded deck plate. Detention Locks Provide keyed interior and exterior access and are ideal for prisons and other buildings requiring a maximum level of security. For added security and weathertightness, the lock is accessed from the exterior through a gasketed, threaded deckplate. Bilco roof hatches can be prepared for field installation of many leading lock brands. Emergency Egress Lock Bilco roof hatches can be supplied with a panic lock for rapid egress in an emergency situation. Available with keyed exterior access. EXPLOSION RELIEF SMOKE VENTS Bilco automatic smoke vents may also be equipped to operate as explosion vents or as combination fire/explosion vents. The explosion release mechanism is preset and factory-tested to release at between 122 kg/m2 and 146kg/m2 of pressure on the underside of the covers. STAINLESS STEEL HARDWARE For installation in highly corrosive environments, Type 316 stainless steel hardware, including slam latch and lifting mechanism assemblies; hold-open arms and guides; and all brackets, hinges, pins, and fasteners. SECURITY GLAZING Allows personnel to visibly scan a secure area before entering or exiting a roof area. Glazing is available in ballistic ratings. 25

26 Floor Doors EXTERIOR INTERIOR FIRE RATED Bilco pit and floor doors are available in a wide range of sizes and configurations to meet virtually any floor access situation-exterior & interior in aluminium or steel. They range from small interior floor doors complete with insets for carpets and tiles to reinforced doors for areas of heavy traffic or high security. Customised designs are also available which can feature security options, motorised operation, a range of finishes and safety aids. DRAINAGE DOORS Constructed for use in exterior applications or in those situations where there is concern of water or other liquids entering the access opening. These doors are supplied with a threaded drain coupling fully welded to the channel frame for connection to a dry or wet well in the field. NON-DRAINAGE DOORS Generally for interior use or exterior applications where water or liquid infiltration is not a concern. Some models are designed to accept a wide variety of flooring materials, allowing them to blend into virtually any building environment. Cover does not protrude into the channel frame Type 316 Stainless steel slam lock Structurally reinforced cover. Withstands a live load of 1464kg/m 2 or more FIRE DOORS One and two hour fire rated doors with a choice of diamond pattern cover or 25mm pan for matching floor finishes. Automatically locks in the vertical/open position with convenient release handle Unique counter opposing spring system means that all Bilco doors meet Manual Handling Regulations Typical Applications Airports Distribution Depots Factories Hospitals Manufacturing Facilities Office Buildings Ports Prisons Retail Centres Schools Sewage Treatment Works Telecommunications Vaults Utilities Warehouses Water/Waste Treatment Works Key Features & Benefits Engineered lift assistance for smooth, easy door operation, regardless of cover size and weight Automatic hold-open arm that locks the cover in the open position to ensure safe egress Even the largest door weighing anything up to 500kg can be easily opened by one person thanks to Bilco's unique counterbalance spring system. Type 316 stainless steel slam lock to prevent unauthorized access Constructed with corrosion resistant materials and hardware 6mm aluminium diamond plate cover Type J-AL door shown 26

27 Engineered excellence for horizontal access! Top-side Removable square key handle Special finishes available Heavy-duty hinges and opening system protected from the elements Continuous EPDM debris gasket Versatile Anchor Tabs for added support Lift assisted counterbalanced cover. Lifting mechanism comprises reinforced composite tubes & electro-coated compression springs All hardware corrosion resistant Top-side - Water drainage channel with drainage outlet Underside - 38mm threaded drain coupling for pipe connection 27

28 Drainage Door Type J-AL TYPE J-AL & JD-AL Aluminium - Single or Double Leaf Ideal for most corrosive environments. Single or double leaf covers are constructed of 6mm diamond pattern plate and reinforced for a 1464 kg/m 2 live load. Features anti-corrosion hardware, standard debris gasket, and a versatile anchoring system for ease of installation. Features on all J/JD aluminium doors include Material Cover and frame are 6mm aluminium Cover Diamond-pattern tread plate reinforced for 1464 kg/m 2 live load Frame Extruded aluminium channel frame with bent down anchor tabs around the perimeter. A 38mm drain coupling is welded under the frame for a pipe connection to a dry well or disposal system. Gasket EPDM gasket mechanically attached to the frame reduces the amount of dirt and debris that may enter the channel frame Hinges Heavy forged aluminium hinges with 6mm Type 316 stainless steel hinge pins Latch Type 316 stainless steel slam lock with fixed interior handle and removable exterior turn/lift handle. Latch release is protected by a flush, gasketed, removable screw plug. Lift Assistance Compression spring operators enclosed in telescopic tubes. Automatic hold-open arm with grip handle release. Finish Mill finish aluminium with a bituminous coating applied to the exterior of the frame Hardware Engineered composite compression spring tubes. Steel compression springs with electrocoated acrylic finish. All other components of door are aluminium or Type 316 stainless steel. Options See page 34 Debris Gasket Adjustable Anchor Tabs STANDARD SIZES & WEIGHTS Type Size - clear internal dimensions Overall Dimensions Weight J-1AL 6mm x 6mm 762mm x 762mm 30 kg J-2AL 760mm x 760mm 912mm x 912mm 40 kg J-3AL 915mm x 760mm (H) 67mm x 912mm 44 kg J-4AL 915mm x 915mm 67mm x 67mm 49 kg J-5AL 65mm x 65mm 1217mm x 1217mm 61 kg JD-1AL 1220mm x 760mm (H) 1372mm x 912mm 66 kg JD-2AL 1220mm x 1220mm 1372mm x 1372mm 79 kg JD-3AL 1220mm x 1830mm (H) 1372mm x 1982mm 6 kg JD-4AL 1525mm x 1525mm 1677mm x 1677mm 9 kg Models with "D" in the Model Type indicate double leaf configuration (H) - Hinge Side 28

29 Drainage Door Type J-AL H20 TYPE J-AL H20 & JD-AL H20 Aluminium - Single or Double Leaf Designed to withstand vehicular traffic in off-street locations. Single or double leaf covers are constructed of 6mm diamond pattern plate and reinforced for AASHTO H-20 wheel loading (14,500 kg. axle load). With all the same features as the Type J-AL, this door is also ideal for most corrosive environments. Features on all J/JD aluminium doors include Material Cover and frame are 6mm aluminium Cover Diamond-pattern tread plate reinforced for H-20 wheel loading. Designed for installation in offstreet locations where the door is not subjected to high density, fast moving traffic. Structural calculations available upon request. Frame Extruded aluminium channel frame with bent down anchor tabs around the perimeter. A 38mm drain coupling is welded under the frame for a pipe connection to a dry well or disposal system. Gasket EPDM gasket mechanically attached to the frame reduces the amount of dirt and debris that may enter the channel frame Hinges Heavy forged aluminium hinges with 6mm Type 316 stainless steel hinge pins Latch Type 316 stainless steel slam lock with fixed interior handle and removable exterior turn/lift handle. Latch release is protected by a flush, gasketed, removable screw plug. Lift Assistance Compression spring operators enclosed in telescopic tubes. Automatic hold-open arm with grip handle release Finish Mill finish aluminium with a bituminous coating applied to the exterior of the frame Hardware Engineered composite compression spring tubes. Steel compression springs with electrocoated acrylic finish. All other components of door are aluminium or Type 316 stainless steel Options See page 34 Debris Gasket Adjustable Anchor Tabs STANDARD SIZES & WEIGHTS Type Size - clear internal dimensions Overall Dimensions Weight J-1AL H20 6mm x 6mm 762mm x 864mm 55 kg J-2AL H20 760mm x 760mm 912mm x 14mm 64 kg J-3AL H20 915mm x 760mm (H) 67mm x 14mm 81 kg J-4AL H20 915mm x 915mm 67mm x 1169mm 87 kg J-5AL H20 65mm x 65mm 1217mm x 1319mm 111 kg JD-1AL H mm x 760mm (H) 1372mm x 14mm 91 kg JD-2AL H mm x 1220mm 1372mm x 1474mm 132 kg JD-3AL H mm x 1830mm (H) 1372mm x 2084mm 226 kg JD-4AL H mm x 1525mm 1677mm x 1779mm 207 kg Models with "D" in the Model Type indicate double leaf configuration (H) - Hinge Side Performance Designed to withstand H-20 wheel loadings suitable for use in off-street locations where not subject to high density traffic 29

30 Non - Drainage Door Type K-1 TYPE K & KD Aluminium - Single or Double Leaf Single or double leaf covers are constructed of 6mm diamond pattern plate and reinforced for a 732 kg/m 2 live load. Features zinc plated and chromate sealed hardware, concealed hinges, and the T-CAM lifting system for ease of operation. Material Cover and frame are 6mm aluminium Cover Diamond-pattern tread plate reinforced for 732 kg/m 2 live load Frame Extruded aluminium angle frame with strap anchors bolted around the perimeter Hinges Cast steel cam-action hinges that are concealed from the exterior of the door Latch Type 316 stainless steel slam lock with fixed interior handle and removable exterior turn/lift handle Lift Assistance Torsion bars that pivot on cam-action hinges. Automatic hold-open arm with grip handle release. Finish Mill finish aluminium with a bituminous coating applied to the exterior of the frame Hardware Zinc plated/chromate sealed Options See page 34 STANDARD SIZES & WEIGHTS Type Size - clear internal dimensions Overall Dimensions Weight K-1 6mm x 6mm 832mm x 832mm 23 kg K-2 760mm x 760mm 982mm x 982mm 30 kg K-3 915mm x 760mm (H) 1137mm x 982mm 35 kg K-4 915mm x 915mm 1137mm x 1137mm 39 kg K-5 65mm x 65mm 1287mm x 1287mm 50 kg KD mm x 1220mm 1442mm x 1442mm 69 kg KD mm x 1830mm (H) 1442mm x 2052mm 97 kg KD mm x 1525mm 1747mm x 1747mm 1 kg Models with "D" in the Model Type indicate double leaf configuration (H) - Hinge Side 30

31 Non - Drainage Door Type TER-1 TYPE TER & TRD Aluminium - Single or Double Leaf - Accepts Architectural Flooring Material These single and double leaf doors are designed with a pan cover to accept a variety of flooring materials up to 25mm in thickness. Each door is spring balanced at the factory to ensure smooth, easy operation upon installation of the specified flooring material in the field. Material Cover and frame are 6mm aluminium Cover Smooth plate reinforced for 732 kg/m 2 live load. Cover designed with 25mm fillable pan for field installation of architectural flooring material (specify flooring material including type, thickness, and weight). Frame Extruded aluminium frame with built in anchor flange around the perimeter Hinges Continuous heavy-duty Type 316 stainless steel hinge Latch Type 316 stainless steel slam lock with fixed interior handle and removable exterior turn/lift handle. Latch release is protected by a flush, gasketed, removable screw plug. Lift Assistance Compression spring operators enclosed in telescopic tubes. Automatic hold-open arm with grip handle release. Finish Mill finish aluminium with a bituminous coating applied to the exterior of the frame Hardware Engineered composite compression spring tubes. Steel compression springs with electrocoated acrylic finish. Type 316 stainless steel hinges. All other hardware is zinc plated/chromate sealed. Options See page 34 STANDARD SIZES & WEIGHTS Type Size - clear internal dimensions Overall Dimensions Weight TER-1 6mm x 6mm 814mm x 814mm 45 kg TER-2 760mm x 760mm 964mm x 964mm 50 kg TER-3 915mm x 760mm (H) 1119mm x 964mm 54 kg TER-4 915mm x 915mm 1119mm x 1119mm 59 kg TER-5 65mm x 65mm 1269mm x 1269mm 75 kg TRD mm x 1220mm 1424mm x 1424mm 91 kg TRD mm x 1830mm (H) 1424mm x 2034mm 125 kg TRD mm x 1525mm 1729mm x 1729mm 129 kg Models with "D" in the Model Type indicate double leaf configuration (H) - Hinge Side Note: Option available with drain coupling. 31

32 Fire Doors Type JFR-2 TYPE JFR Steel - Single Leaf - One Hour Fire-Rated Fire-rated floor doors allow you to specify convenient access through a fire-rated floor without jeopardizing fire code compliance. Doors contain flames and limit heat transmission between fire-rated floor/ceiling assemblies, and feature fire-proof coating, balanced cover operation, and are available with a specially designed closing mechanism to ensure the door closes automatically when a fire occurs. Material Cover and frame are 6mm steel Cover Diamond pattern plate reinforced for 1464kg/m 2 live load. Note: special sizes are available, but certification only available with a maximum size of 1.14 m2. Intumescent fire coating applied to the underside of the cover. Frame Formed channel frame with anchor angle welded around the perimeter. Intumescent fire coating applied on the interior surfaces of the frame. Hinges Heavy forged brass hinges with mm Type 316 stainless steel hinge pins Latch Type 316 stainless steel slam lock with fixed interior handle and removable exterior turn/lift handle. (Note: can be supplied with self-closing mechanism on sizes 762mm in width and greater when specified, see picture on page 33). Lift Assistance Compression spring operators enclosed in telescopic tubes. Automatic hold-open arm with grip handle release. Compression spring operators enclosed in telescopic tubes. Mechanical hold-open system with release button automatically holds the cover in the open position. Performance Tested in accordance with BS476: Part 22 and approved for a 1-hour fire rating when Ratings exposed to fire from the underside Finish Alkyd base red oxide primer Hardware Engineered composite compression spring tubes. Steel compression springs with electrocoated acrylic finish. All other hardware is zinc/plated and chromate sealed. Options See page 34 Diamond pattern cover 32 STANDARD SIZES & WEIGHTS Type Size - clear internal dimensions Overall Dimensions Weight Performance JFR-1 6mm x 6mm 826mm x 826mm 99 kg BS476: Part 22 JFR-2 760mm x 760mm 976mm x 976mm 132 kg for integrity & insulation JFR-3 915mm x 760mm (H) 1131mm x 976mm 158 kg JFR-4 915mm x 915mm 1131mm x 1131mm 176 kg JFR-5 65mm x 65mm 1281mm x 1281mm 236 kg JFR-6 760mm x 1220mm (H) 976mm x 1436mm 190 kg JFR-7 915mm x 1220mm (H) 1131mm x 1436mm 221 kg JFR-8* 760mm x 1525mm (H) 976mm x 1741mm 227 kg JFR-9* 915mm x 1525mm (H) 1131mm x 1741mm 265 kg JFR-* 915mm x 1830mm (H) 1131mm x 2046mm 306 kg *Models without BS476: Part 22 certification (H) - Hinge Side Certified by Chiltern Fire International

33 Fire Doors Type FR-2 TYPE FR Aluminium - Single Leaf - Two Hour Fire-Rated Maintains the fire rating of a 2-hour floor/ceiling assembly where access is required between building floors. Features include an optional UL Listed automatic closing system, intumescent fire resistant coating, and a pan cover designed to accept architectural flooring materials. Material Cover and frame are 6mm aluminium Cover Aluminium plate reinforced for 732 kg/m 2 live load. Intumescent fire coating applied to the underside of the cover. Designed with 25mm fillable pan for field installation of architectural flooring material up to 13mm thickness (specify flooring material including type, thickness, and weight). The remaining depth must be filled with concrete to maintain the fire rating of the door assembly (if finish flooring is not desired, the pan must be filled with 25mm of concrete). Frame Extruded aluminium frame with built in anchor flange around the perimeter. Intumescent fire coating applied on the interior surfaces of the frame Hinges Continuous heavy-duty Type 316 stainless steel hinge Latch Pneumatic self closing system that automatically closes the door in the event of a fire when heat parts a UL-listed 74 C fusible link Lift Assistance Compression spring operators enclosed in telescopic tubes. Mechanical hold-open system with release button automatically holds the cover in the open position. Performance Tested in accordance with BS476: Part 22, and UL-listed Ratings (File R15197) as having a 2-hour fire rating when exposed to fire from the underside Finish Mill finish aluminium with a bituminous coating applied to the exterior of the frame Hardware Engineered composite compression spring tubes. Steel compression springs with electrocoated acrylic finish. Type 316 stainless steel hinges. All other hardware is zinc plated/chromate sealed. Options See page 34 STANDARD SIZES & WEIGHTS Type Size - clear internal dimensions Overall Dimensions Weight FR-2 740mm x 600mm (H) 962mm x 962mm 123 kg FR-3 890mm x 600mm (H) 1117mm x 962mm 126 kg FR-4 890mm x 750mm (H) 1117mm x 1117mm 148 kg FR-5 15mm x 9mm (H) 1267mm x 1267mm 167 kg FR-6 735mm x 60mm (H) 962mm x 1422mm 149 kg Available without self-closing mechanism suffix LC (H) - Hinge Side New self-closing mechanism Simplified design takes up less frame area Requires lower maintenance More cost effective UL Listed Performance BS476: Part 22 for integrity & insulation Top side - ready to accept floor finish. Certified by Chiltern Fire International 33

34 Floor Door Options Bilco floor doors can include any of the modifications shown below. STAINLESS STEEL In highly corrosive environments or where there is prolonged exposure to hot water or steam all steel and aluminium doors are available with Type 316 stainless steel hardware. Included are all parts of the latch and lifting mechanism assemblies; holdopen and guide arm and guides; and all brackets, hinges, pins and fasteners. PAINT FINISHES All aluminium doors can be supplied with an anodized finish. Other custom finishes are available when specified. Cylinder lock with a keyway protected by a threaded cover plug Recessed padlock hasp covered by a flush hinged lid LOCKS & LATCHES Four standard lock options are available to add security and prevent unauthorized access. Additional lock options include padlock lugs welded to the exterior door surface, high security detention locks and magnetic locks are available on request. Security cover McGuard plugs Panic lock OTHER OPTIONS Handrails Steel or aluminium grating Slip resistant coatings Submersible pump guide rail brackets Metal enclosed insulation Drop-in installation modifications Snow and ice melting cables Electric motor operation. Stainless steel hardware Special finishes Grating panel covers Handrails 34

35 Floor Door Safety Products Ideal for safer access and a safer working environment LADDER UP SAFETY POST LadderUp Safety Posts provide easier, safer ladder access through roof hatches, floor doors, and manholes. This telescopic post permanently mounts to the top two rungs of any fixed ladder, providing a positive hand-hold and enabling the user to enter or exit an opening in an upright and balanced position. Available in four different finishes. Install on fixed ladder(s) below hatch cover(s), LadderUp safety post Model as manufactured by The Bilco Company. Device shall be (refer to chart for material/finish* of model specified). It shall be designed with a telescoping tubular section that locks automatically when fully extended. Upward and downward movement shall be controlled by a stainless steel spring balancing mechanism. Unit shall be completely assembled with fasteners for securing to the ladder rungs in accordance with the manufacturer s instructions. * If installation is to be in corrosive atmosphere, specify Model LU-2, LU-3 or LU-4 as conditions warrant. STANDARD SIZES & WEIGHTS Type Description kg LU-1 BLK Steel/black enamel 11 LU-2 Steel hot dip galv 11 LU-3 Stainless type LU-4 Aluminium mill finish 7 Key Features & Benefits Telescopic design is spring balanced for ease of operation Adjustable mounting hardware accommodates virtually any ladder rung size or spacing Automatically locks in the fully raised position to provide the user with a firm and steady hand-hold Handy release lever allows the post to be easily lowered to its retracted position Available in four levels of corrosion resistance to provide many years of trouble free, dependable service. Adjustable mounting Automatically locks off Telescopic design Handy release lever FALL PROTECTION GRATING Fall protection grating system is available for J-AL & JD-AL Bilco floor doors. Retrofit kits are also available for field installation. The fibreglass panel includes lift assistance and an automatic hold open arm. Grating panel(s) shall be fibreglass moulded in one piece with load bearing bars in both directions to allow for use without continuous side support. Panel shall be designed to support a 1464 kg/m2 live load and be high visibility safety yellow in color. Torsion rod lift assistance shall be provided for ease of operation and a hold open arm shall also be included to automatically lock the panel in the fully open 90 degree position. A release handle shall be provided to allow the grating panel to be closed and there shall be a provision for locking the panel to prevent unauthorized access. Hold open arm shall be aluminium with a stainless steel release handle. All other hardware, including mounting brackets, hinges, torsion rod, padlock loop, and fasteners, shall be Type 316 stainless steel. Manufacturer shall provide a twenty-five year warranty against defects in material and workmanship. Key Features & Benefits Provides a permanent means of fall protection under access doors Fibreglass panel includes lift assistance and an automatic hold open arm for ease of operation and user safety The grating panel consists of 25.4mm moulded fibreglass squares Equipped with stainless steel hardware for maintenance-free performance Grating panel rated for a 1464 kg/m 2 live load Grate operates independently of the cover reinforcing 25 year warranty 35

ROOF ACCESS HATCHES LADDERS SMOKE VENTS FLOOR ACCESS SAFETY PRODUCTS. The Worldwide Source for Speciality Access Products

ROOF ACCESS HATCHES LADDERS SMOKE VENTS FLOOR ACCESS SAFETY PRODUCTS. The Worldwide Source for Speciality Access Products ROOF ACCESS HATCHES SMOKE VENTS FLOOR ACCESS SAFETY PRODUCTS LADDERS The Worldwide Source for Speciality Access Products BILCO HISTORY The Bilco Company was established in America in 1926 and has for many

More information

ROOF ACCESS HATCHES SMOKE VENTS FLOOR ACCESS LADDERS SAFETY PRODUCTS

ROOF ACCESS HATCHES SMOKE VENTS FLOOR ACCESS LADDERS SAFETY PRODUCTS ROOF ACCESS HATCHES SMOKE VENTS FLOOR ACCESS LADDERS SAFETY PRODUCTS The Worldwide Source for Speciality Access Products BILCO HISTORY The Bilco Company was established in America in1926 and has for many

More information

ROOF ACCESS HATCHES SMOKE VENTS FLOOR ACCESS LADDERS SAFETY PRODUCTS

ROOF ACCESS HATCHES SMOKE VENTS FLOOR ACCESS LADDERS SAFETY PRODUCTS ROOF ACCESS HATCHES SMOKE VENTS FLOOR ACCESS LADDERS SAFETY PRODUCTS The Worldwide Source for Speciality Access Products CONTENTS ROOF ACCESS HATCHES 4-11, 62-64 SMOKE VENTS 12-19, 62-64 FLOOR ACCESS 20-43,

More information

SMOKE VENTS. The Worldwide Source for Speciality Access Products

SMOKE VENTS. The Worldwide Source for Speciality Access Products SMOKE VENTS The Worldwide Source for Speciality Access Products Smoke Vents Natural Smoke and Heat Exhaust Ventilators (NSHEV) Bilco smoke ventilators are fully compliant to the Construction Products Directive

More information

DOWNSPOUT Sc.ale: None

DOWNSPOUT Sc.ale: None ~ SEE DETAIL 05/2.0 FOR EDGE DETAILING ~ NE~ SCHEDULE 80 PVC ELBO~ AS REQUIRED TO TURN UNDER SOFFIT FOR INSTALLATION OF NE~ VERTICAL DOWNSPOUT NE~ DOWNSPOUT STRAP ATIACHED TO EXISTING WALL ~ITH NE~ MASONRY

More information

Roofing Products. > Roof Access Hatches > Automatic Smoke Vents > Safety Products

Roofing Products. > Roof Access Hatches > Automatic Smoke Vents > Safety Products Roofing Products > Roof Access Hatches > Automatic Smoke Vents > Safety Products 800.366.6530 WWW.BILCO.COM Introduction Manufacturing Trumann, Arkansas Headquarters New Haven, Connecticut BILCO s History

More information

Commercial Products. > Roof Hatches > Automatic Smoke Vents > Floor Access Doors

Commercial Products. > Roof Hatches > Automatic Smoke Vents > Floor Access Doors Commercial Products > Roof Hatches > Automatic Smoke Vents > Floor Access Doors 800.366.6530 WWW.BILCO.COM Introduction Manufacturing Trumann, Arkansas Headquarters New Haven, Connecticut BILCO s History

More information

ROOF ACCESSORIES Division Rooftop Pipe Supports Division Roof Hatches

ROOF ACCESSORIES Division Rooftop Pipe Supports Division Roof Hatches ROOF ACCESSORIES Division 07 72 30 Rooftop Pipe Supports Division 07 72 33 Roof Hatches Roof Safety Railings Safety Posts Equipment Hatches Division 07 72 36 Smoke Vents ROOF HATCH - LADDER ACCESS DIAMOND

More information

Roof Accessories. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents

Roof Accessories. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents Roof Accessories Distributed by: BEST MATERIALS Ph: 800-474-7570, 602-272-8128 www.bestmaterials.com Email: Sales@BestMaterials.com Division 07 72 33 Roof Hatches Roof Safety Rails Safety Posts Division

More information

3. Roof Expansion Joints between New Building and Existing Building.

3. Roof Expansion Joints between New Building and Existing Building. SECTION 077200 - ROOF ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Amendments to General Conditions and Division 01 Specification

More information

SECTION ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 07 72 00 ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Roof Hatches Smoke Vents. Complementary B u i l d i n g Products

Roof Hatches Smoke Vents. Complementary B u i l d i n g Products Roof Hatches Smoke Vents Complementary B u i l d i n g Products Roof Hatches Nystrom Roof Hatches and Scuttles are manufactured to solve all of your roof access needs. Custom sizing, materials, and color

More information

SECTION ROOF ACCESSORIES

SECTION ROOF ACCESSORIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 72 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Hobby Parking Office HOU/ Proj./ No. 738 Houston, Texas 100% Bid and Construction Documents- Addendum #2, January 26, 2017

Hobby Parking Office HOU/ Proj./ No. 738 Houston, Texas 100% Bid and Construction Documents- Addendum #2, January 26, 2017 SECTION 077200 - ROOF ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

floor access The Worldwide Source for Speciality Access Products

floor access The Worldwide Source for Speciality Access Products floor access The Worldwide Source for Speciality Access Products Floor Access Floor Doors Exterior Interior Fire Rated Bilco pit and floor doors are available in a wide range of sizes and configurations

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

SPECIFICATIONS SECTION UL LISTED HEAT AND SMOKE VENTS

SPECIFICATIONS SECTION UL LISTED HEAT AND SMOKE VENTS SPECIFICATIONS SECTION 07 72 00 PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Prefabricated UL Listed heat and smoke vents, with Skypro UL 972 Impact resistant Skywave Arc domed lids, curbs, hardware

More information

B. Shop Drawings: Show fabrication and installation details for roof accessories.

B. Shop Drawings: Show fabrication and installation details for roof accessories. SECTION 077200 - ROOF ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Roof curbs. 2. Equipment supports. 3. Roof hatches. 4. Dropout-type heat and smoke vents. 5. Hatch-type

More information

Section SECTIONAL INSULATED STEEL DOORS

Section SECTIONAL INSULATED STEEL DOORS 1 GENERAL 1.1 GENERAL REQUIREMENTS General Conditions and Division 01 apply to this section. 1.2 RELATED WORK Section 05500: Miscellaneous Metal Fabrication Section 07900: Joint Sealers Section 09900:

More information

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS SECTION 08620 COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947

WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947 WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947 WEATHER BREAKER MODEL 175 Whether you are keeping the cold out or in, nothing makes better sense for your manufacturing facility or warehouse

More information

Sliding Door Systems

Sliding Door Systems Sliding Door Systems Standard Sliding System Reference Brand: Sapa Building System Plaisance 24 GENERAL DESCRIPTION Sliding window and door system with a frame depth of 50 mm (two rail version), 97mm (three

More information

Roof Accessories. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents.

Roof Accessories. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents. Roof Accessories Division 07 72 33 Roof Hatches Roof Safety Rails Safety Posts Division 07 72 36 Smoke Vents www.activar.com Construction Products Group ROOF HATCH: Galvanized Steel or Aluminum RHG & RHA

More information

Uniclass G321:G24 L414 CI/SfB (37.41) December Flat Roofing and Waterproofing Systems. Alumasc. Daylighting Systems

Uniclass G321:G24 L414 CI/SfB (37.41) December Flat Roofing and Waterproofing Systems. Alumasc. Daylighting Systems Flat Roofing and Waterproofing Systems Uniclass G:G L CI/SfB (7.) December 00 Alumasc Introduction Contents Introduction Alumasc A Range Superior Modular Rooflights Alumasc B Range Standard Modular Rooflights

More information

Roof AccessoRies. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents. Construction Products Group

Roof AccessoRies. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents. Construction Products Group Roof AccessoRies Division 07 72 33 Roof Hatches Roof Safety Rails Safety Posts Division 07 72 36 Smoke Vents Construction Products Group RooF HaTcH: Galvanized Steel or aluminum RHG & RHa Series certifications:

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Building Your Visions

Building Your Visions Ferguson C EAP Curtain Wall Systems Ferguson-EAP 130HP Series High Performance Curtain Wall System Ferguson s 130HP curtain wall system was developed for high performance double, triple, unique acoustical

More information

SECTION ACCESS DOORS AND FRAMES

SECTION ACCESS DOORS AND FRAMES SECTION 08310 ACCESS DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. [Fire rated] [and] [Non-fire rated] wall access panels. 2. [Fire rated] [and] [Non-fire rated] ceiling access

More information

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section. SECTION 10 5300 ALUMINUM WALKWAY COVERS Part 1 General 1.01 Related Documents A. The requirements of Division 1 specifications shall apply to work specified in the section. 1.02 References A. International

More information

SECTIONAL ALUMINUM DOORS

SECTIONAL ALUMINUM DOORS PART 1 GENERAL 1.1. GENERAL REQUIREMENTS 1.1.1. General Conditions and Division 01 apply to this section. 1.2. RELATED WORK Section 05500: Section 07900: Section 09900: Section 11169: Division 16: Metal

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 077200 - ROOF ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

METAL LADDERS (LADDER SAFETY GATE FALL PROTECTION)

METAL LADDERS (LADDER SAFETY GATE FALL PROTECTION) Page 1 of 6 SECTION 05515 METAL LADDERS (LADDER SAFETY GATE FALL PROTECTION) PART 1 - GENERAL 1.1 SECTION INCLUDES A. Specialty custom designed, spring assisted, self-closing LADDER SAFETY GATE (LSG) for

More information

P R O D U C T - S P E C

P R O D U C T - S P E C P R O D U C T - S P E C Drylight TM Skylight Specification Section 08600 Skylights June 2008 This PRODUCT-SPEC is intended to provide specifiers with guidelines to properly specify Carlisle s Drylight

More information

Curtain Wall Stick System (Capped)

Curtain Wall Stick System (Capped) Curtain Wall Stick System (Capped) Stick Construction Capped Curtain Wall Reference Brand: Sapa Building System Elegance 52 ST GENERAL DESCRIPTION Grid based thermally insulated curtain wall system with

More information

Kingspan Day-Lite Kapture Data Sheet

Kingspan Day-Lite Kapture Data Sheet Light + Air UK & Republic of Ireland Kingspan Day-Lite Data Sheet KS700DLK, KS1400DLK, KS0DLK 2 Kingspan Day-Lite KS700DLK, KS1400DLK, KS0DLK Application KS700DLK, KS1400DLK, KS0DLK & KS2750DLK rooflights

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

SECTION ORNAMENTAL ALUMINUM FENCING

SECTION ORNAMENTAL ALUMINUM FENCING SECTION 032300 ORNAMENTAL ALUMINUM FENCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

LOG COLLEGE MIDDLE SCHOOL

LOG COLLEGE MIDDLE SCHOOL PART 1-GENERAL 1.1 SUMMARY A. This section includes the following: 1. Curb-mounted plastic glazed skylights. B. Refer to roofing system sections for roofing accessories to be built into the roofing system

More information

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT SPECIFICATION EO-1124 REVISION 3 November 2013 EFFECTIVE DATE November 11,

More information

SECTION MISCELLANEOUS METALS

SECTION MISCELLANEOUS METALS PART 1 GENERAL 1.1 WORK OF THIS SECTION A. Contractor shall provide all labor, materials, equipment and incidentals as shown, specified and required to furnish and install all miscellaneous metal fabrications

More information

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Section 08520 Aluminum Windows PART 1: WORK INCLUDED A. The conditions of the contract and applicable sections of Division

More information

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope. SECTION 08 4519 - POLYCARBONATE WALL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior System: The design, manufacture and installation of an aluminum and polycarbonate insulating translucent system.

More information

.1 Section Documents and samples to be submitted..2 Section Construction and demolition waste management and disposal.

.1 Section Documents and samples to be submitted..2 Section Construction and demolition waste management and disposal. (GX-175-A) Page 1 of 6 PART 1. GENERAL 1.1 RELATED SECTIONS.1 Section 01 33 00 Documents and samples to be submitted..2 Section 01 74 21 Construction and demolition waste management and disposal..3 Section

More information

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS DIVISION 10 SPECIALTIES SECTION 10 51 13 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SPECIFICATION For the Supply and Installation of BRITAL UN Four Sided Unitized Structurally Glazed Curtain Walling

SPECIFICATION For the Supply and Installation of BRITAL UN Four Sided Unitized Structurally Glazed Curtain Walling SPECIFICATION For the Supply and Installation of BRITAL UN-4-76 Four Sided Unitized Structurally Glazed Curtain Walling Issue date Revision Comment 07/05/09 R0 Draft 11/05/09 R1 Approved for Issue R1 Amended

More information

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System SECTION 13096 RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13096-1 RF MODULAR PAN SYSTEM PART 1 GENERAL 1.1

More information

Expansion Joint Covers

Expansion Joint Covers Expansion Joint Covers 07 95 00 (079513) PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Supplementary Conditions and Division-1

More information

Series PV. Compact Switchgear Cabinets. Construction subject to change without notice Dimensions in mm

Series PV. Compact Switchgear Cabinets. Construction subject to change without notice Dimensions in mm Series PV Single layer design, thermal conductivity k = 5 W/m 2 K For wall mounting by hanging and standing installation Torsion resistant, self-supporting casing without joints, corrosion and seawater

More information

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware. 1 SECTION 08 4210 ALL GLASS ENTRANCES PART 1 - GENERAL 1.01 SUMMARY A. This section includes: 1. Vestibule doors matching entrance doors. 2. Sidelites. B. Related work in other sections: 1. Lock cylinders

More information

SECTION ACCESS PANELS

SECTION ACCESS PANELS SECTION 08310 ACCESS PANELS PART 1: GENERAL 1.01 RELATED DOCUMENTS Drawings and general provisions of the contract, including supplementary conditions and Division 1 specification sections, apply to this

More information

SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF. Two Sided Structurally Glazed Curtain Walling. (Horizontal Structural joints)

SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF. Two Sided Structurally Glazed Curtain Walling. (Horizontal Structural joints) SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF Two Sided Structurally Glazed Curtain Walling (Horizontal Structural joints) Issue date Revision Comment R0 Draft 05/05/09 R1 Approved

More information

Model STORM GRILLE Brick or Straight Pattern High Stress Rolling Grilles

Model STORM GRILLE Brick or Straight Pattern High Stress Rolling Grilles Model STORM GRILLE Brick or Straight Pattern High Stress Rolling Grilles NOTE: For specifications, architects must choose from a variety of options. The standard choice will be shown first in plain text

More information

MPG Series 2250T Thermally Broken Aluminum Window

MPG Series 2250T Thermally Broken Aluminum Window SECTION 08520 ALUMINUM WINDOWS P a g e 1 MPG Series 2250T Thermally Broken Aluminum Window PART 1 GENERAL 1.01 Work Included A. Furnish and install aluminum architectural windows complete with hardware

More information

Unitised Curtain Wall Beaded

Unitised Curtain Wall Beaded Unitised Curtain Wall Beaded Glazed Frame Unitised Curtain Wall Reference Brand: Sapa Building System Elegance 72 GF GENERAL DESCRIPTION Unitised curtain wall system using glazing beads for glass retention.

More information

SECTION ORNAMENTAL WELDED STEEL FENCING

SECTION ORNAMENTAL WELDED STEEL FENCING SECTION 032300 ORNAMENTAL WELDED STEEL FENCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society

More information

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter

More information

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION ALUMINUM HANDRAIL SYSTEMS SECTION 05520 ALUMINUM HANDRAIL SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes aluminum handrails and railings. B. Related Work: 1. Section 03300 - Cast-in-Place Concrete C. References: 1. American

More information

SECTION DETAILS (MECHANICALLY ASSEMBLY)

SECTION DETAILS (MECHANICALLY ASSEMBLY) COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) SECTION DETAILS (DOOR ASSEMBLY)

More information

Aluminium Coping Systems

Aluminium Coping Systems Aluminium Coping Systems Excellence in aluminium engineering >Company Profile Alifabs leads the field in the design, production and installation of aluminium building products. Our experience spans some

More information

SECTION Motor Operated Horizontal Sliding Sound Control Door

SECTION Motor Operated Horizontal Sliding Sound Control Door SECTION 08 34 73 Motor Operated Horizontal Sliding Sound Control Door PART 1 GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of the Contract, including general and Supplementary Conditions

More information

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS VELUX SECTION 08 62 00 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Dynamic dome unit skylight with formed curb counterflashing for mounting on site-built or prefabricated roof curbs, for flat, low-slope and

More information

08620 UNIT SKYLIGHTS Tufflite double polycarbonate glazed Frb

08620 UNIT SKYLIGHTS Tufflite double polycarbonate glazed Frb PART 1 GENERAL 1.1 SECTION INCLUDES A. Prefabricated Fixed Skylights. 1.2 RELATED SECTIONS A. Section 07500 - Membrane Roofing. 1.3 REFERENCES A. Aluminum Association (AA): 1. Specifications for Aluminum

More information

(G) DOORS & WINDOWS LIST OF BUREAW OF INDIAN STANDARD CODE OF PRACTICE (ISI)

(G) DOORS & WINDOWS LIST OF BUREAW OF INDIAN STANDARD CODE OF PRACTICE (ISI) (G) DOORS & WINDOWS LIST OF BUREAW OF INDIAN STANDARD CODE OF PRACTICE (ISI) 4021 : Specification for teak wood. 287 : Recommendation for maximum permissible moisture content 1141 : Specification for code

More information

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans. INC. ENGINEERING/CONSTRUCTION/MANUFACTURING /WWW.CONTAINWATER.COM SPRINGS, TEXAS. 78620 MODEL SPECIFICATION FOR CONTAIN WATER INC. DOME ROOF CORRUGATED STEEL WATER STORAGE TANKS. Part 1 GENERAL 1.01 SECTION

More information

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. SECTION 08625 METAL FRAMED SKYLIGHT PART 1 GENERAL 1.01 SECTION INCLUDES: A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. B. Fabrication

More information

1.1.2 All window frames will be Kite marked to indicate compliance with these standards.

1.1.2 All window frames will be Kite marked to indicate compliance with these standards. PVC-u WINDOWS Specification 1.1 General Spcification 1.1.1 All products supplied will fully comply with current editions of all relevant British Standards and Codes of Practice, and in particular all profiles

More information

Aluminum Perforated Rolling Door

Aluminum Perforated Rolling Door Model ALUMA-VISION Perforated Curved or Flat Slats Rolling Service Door NOTE: For specifications, architects must choose from a variety of options. The standard choice will be shown first in plain text

More information

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1. PAGE 1 PART 1 GENERAL 1.1 REFERENCE.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1. 1.2 RELATED WORK SPECIFIED ELSEWHERE.1 Cast

More information

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1 GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials and services to furnish and install SECURITY

More information

MONK W20 range of mild steel windows

MONK W20 range of mild steel windows MONK W20 range of mild steel windows MONK METAL WINDOWS LIMITED Ovaltine Factory, Kings Langley Contractor: Costain GENERAL Introduction: The W20 range of mild steel windows is taken from the wide range

More information

MPG Series 2780-ZS Thermally Broken Aluminum Window Zero Sightline Series

MPG Series 2780-ZS Thermally Broken Aluminum Window Zero Sightline Series SECTION 08520 ALUMINUM WINDOWS P a g e 1 MPG Series 2780-ZS Thermally Broken Aluminum Window Zero Sightline Series PART 1 GENERAL 1.01 Work Included A. Furnish and install aluminum architectural windows

More information

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including: Page 1 of 7 SECTION 083925 MECHANICAL ROOM FLOOD DOORS AND FRAMES **Note to Specifier** This specification contains component and configuration options. Where indicated, choose the appropriate choice for

More information

SECTION ACCESS DOORS AND FRAMES

SECTION ACCESS DOORS AND FRAMES 11303, 26 th avenue Montreal, Quebec Canada H1E 6N6 Phone: (800) 479-1489 Fax: (800) 297-1489 PRODUCT GUIDE SPECIFICATION SECTION 08 31 00 S PART 1 - GENERAL 1.1 SUMMARY A. Provide access doors, frames

More information

Domes Pyramids Opening Rooflights Flatglass Rooflights

Domes Pyramids Opening Rooflights Flatglass Rooflights Domes Pyramids Opening Rooflights Flatglass Rooflights The Roofglaze range of modular rooflights offers a huge variety of solutions for introducing natural light into all kinds of buildings, with options

More information

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND SECTION 08352 FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND THREE PART SHORT FORM SPECIFICATIONS (CSI) PART 1 GENERAL 1.1 SUMMARY A. Section Includes: manually operated, side folding accordion- type products

More information

SECTION SOLID PHENOLIC PLASTIC TOILET PARTITIONS

SECTION SOLID PHENOLIC PLASTIC TOILET PARTITIONS PRODUCT SPECIFICATION SERIES 1080/1180 PART 1 - GENERAL 1.01 Work Included SECTION 10170 SOLID PHENOLIC PLASTIC TOILET PARTITIONS A. Toilet Compartments B. Urinal Screens C. Shower Dividers D. Dressing

More information

SOTA THERMO 3 SERIES SPECIFICATION FOR PREGLAZED & UNITIZED THERMO 3 CURTAINWALL SYSTEM

SOTA THERMO 3 SERIES SPECIFICATION FOR PREGLAZED & UNITIZED THERMO 3 CURTAINWALL SYSTEM 1. General 1.1 Description of Work a. Furnish the labour, materials and other services to complete the fabrication and installation of Thermo 3 Series framing, including all materials and fitments required

More information

DL-200. Specifications

DL-200. Specifications DL-200 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Structural Preformed Metal Roofing PART 1: GENERAL 1.01

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-07 72 20 (August 2009) --------------------------- Preparing Activity: USACE Nontechnical Title Revision (August 2015) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

SOTA HYBRID-WALL SPECIFICATION FOR PRE-GLAZED & UNITIZED HYBRID-WALL SYSTEM

SOTA HYBRID-WALL SPECIFICATION FOR PRE-GLAZED & UNITIZED HYBRID-WALL SYSTEM 1. General 1.1 Description of Work a. Furnish the labour, materials and other services to complete the fabrication and installation of Hybrid-Wall Series framing, including all materials and fitments required

More information

where high efficiency is the standard

where high efficiency is the standard Access Doors 2016 where high efficiency is the standard Experience Milcor offers years of experience in the manufacture of a broad range of products and services for residential, commercial, institutional

More information

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans. INC. ENGINEERING/CONSTRUCTION/MANUFACTURING /WWW.CONTAINWATER.COM SPRINGS, TEXAS. 78620 MODEL SPECIFICATION FOR CONTAIN WATER INC. 30 DEGREE ROOF CORRUGATED STEEL WATER STORAGE Part 1 GENERAL 1.01 SECTION

More information

SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage:

SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage: Item Description Smoke Vent Product Information Description: Smoke Vents (Acrylic) provide a double glazed, 100% Impact Modified 0.181" (4.6 mm) outer lens and a 50% Impact Modified 0.120" (3 mm) inside

More information

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE Blast Resistant Enhanced Curtain Wall Blast Resistant Enhanced Curtain Wall Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION Grid based thermally insulated curtain wall system with

More information

Expansion Joint Covers (079513)

Expansion Joint Covers (079513) Expansion Joint Covers 07 95 00 (079513) PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Supplementary Conditions and Division-1

More information

Commercial Dome Unit Skylight - Guide Specification

Commercial Dome Unit Skylight - Guide Specification Commercial Dome Unit Skylight - Guide Specification For over 70 years, VELUX has been delivering energy efficient daylight to indoor spaces where people, live, work, and play. VELUX is the world leader

More information

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Klick KS500 DLKK

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Klick KS500 DLKK Fabrications, Safety & Lighting Solutions Kingspan Day-Lite KS500 DLKK Applications Kingspan Day-Lite is a secret-fix wall light system typically suited for vertical applications. Featuring an innovative

More information

COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY)

COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) SECTION DETAILS (DOOR ASSEMBLY)

More information

INC Pre-Assembled Structures

INC Pre-Assembled Structures INC Pre-Assembled Structures Drop-In In-Place Noise Control Pre-Engineered Factory Finished High Performance Rugged Durability INC pre-assembled structures offer a high performance, cost-effective alternative

More information

SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage:

SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage: Item Description Smoke Vent Product Information Description: Smoke Vents (Acrylic) provide a double glazed, 100% Impact Modified 0.181" outer lens and a 50% Impact Modified 0.120" inside lens that is hail

More information

HALLOWELL FORT KNOX Modular Utility Storage and Workbench System Specifications

HALLOWELL FORT KNOX Modular Utility Storage and Workbench System Specifications General: All modular components shall be "FORT KNOX Modular Utility Storage and Workbench System" components as manufactured by Hallowell or approved equal. All workbench pedestals, cabinets and lockers

More information

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1 GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials, and services to furnish and install VERSA SHIELD Window

More information

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including: Page 1 of 7 SECTION 083925 MECHANICAL ROOM FLOOD DOORS AND FRAMES **Note to Specifier** This specification contains component and configuration options. Where indicated, choose the appropriate choice for

More information

Piping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System

Piping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System TCC-1 Pipe Penetration System TCC-3 Pipe Penetration System TCC-5 Pipe Penetration System 54 years of excellence... www.thybar.com 82 Table of Contents General Information 84 Specifications 85 Assembly

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]

More information

SGL2100 Sliding Systems

SGL2100 Sliding Systems SGL2100 Sliding Systems High Performance Thermally Broken Sliding System Reference Brand: Sapa Building System Confort 160 Lift and slide GENERAL DESCRIPTION Thermally insulated sliding door system with

More information

K. All mechanical rooms shall be designed with a minimum 3-1/2 dropped floor.

K. All mechanical rooms shall be designed with a minimum 3-1/2 dropped floor. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information