Improving plumbing installations for buildings constructed on reactive and unstable soils

Size: px
Start display at page:

Download "Improving plumbing installations for buildings constructed on reactive and unstable soils"

Transcription

1 Fact sheet 4 Improving plumbing installations for buildings constructed on reactive and unstable soils Introduction The Department of Housing and Public Works is seeking public feedback on reform options to improve plumbing installations for buildings constructed on reactive 1 and unstable soils. Based on the feedback, a cost benefit analysis will be undertaken to ensure there is a sound economic case for any Government action. Background The Queensland Building and Construction Commission (QBCC) has identified reactive and unstable soils as a significant cause of damage to foundations of houses and in-ground plumbing and drainage installations. The QBCC Home Warranty Scheme paid out a total of $40.1 million in insurance claim costs during , with $9.2 million being for subsidence. Drainage is 6th in the top 10 most common defects in building construction. Standards Australia Working Group review The Standards Australia Working Group is currently reviewing the AS Plumbing and Drainage series technical requirements for drainage installations in reactive and unstable soils. The focus of the review is to align compliant solutions with the Australian Standard for residential slabs and footings 2. However, it is expected that amendments from the review will not be included in the Plumbing Code of Australia until 2019 or later. 1 Reactive soils are clay-type soils that swell on wetting and shrink on drying. The soil type is classified by a testing procedure as part of the building planning/approval process. Drains laid below ground in reactive soils will need to provide for ground movement. 2 AS Residential slabs and footings

2 What are the proposed reform options? The Department has identified the following options to address damage to in-ground plumbing installations resulting from movement of reactive soils: Option 1 Maintain status quo At present, policies and standards for site classification, design for footings and slabs, and plumbing and drainage are implemented to minimise damage from reactive and unstable soils. The QBCC, through its Rectification of Building Work Policy 3, stipulates that the building contractor must ensure that a slab/footing design is carried out by a certified engineer. If necessary, the requirements for articulation (flexible joints) in storm water and sanitary drainage are included in the slab/footing design and must be carried out by the contractor as specified. To complete the process, an engineer or building certifier should certify that the specified design has been complied with by the contractor 4. At present, there are no requirements in the Australian Standard 5 (refer to clause 5.6) to allow for vertical movement between the riser pipes and drainage systems under the slab and the fixtures above the slab, in reactive and unstable soils of H & E 6 classifications. The availability of WaterMark approved flexible joints provide suitable solutions for articulation of drains; however the use of these fittings is not mandatory. Option 2 Amend the Queensland Plumbing and Wastewater (QPW) Code to adopt standardised solutions for the articulation of plumbing, drainage and stormwater services located in reactive and unstable soils. To provide clarity to the plumbing and drainage industry, the QPW code could be amended to provide the following: standardised solutions, including diagrams (see Attachment A examples only 7 ) regarding differential movement between slab systems and in-ground drainage installations a mandatory requirement that expansion fittings must be installed on vertical riser pipes that penetrate, attach to or emerge from underneath slab systems to accommodate differential movements and stresses in reactive and unstable soils of H & E classifications. 3 QBCC s Rectification of Building Work Policy is called up under the Queensland Building and Construction Commission Regulation 2003, Schedule 1A, which is called up under the Queensland Building and Construction Commission Act 1991 (Part 2) Subdivision 3, Section QBCC s guideline Defective residential construction work causing subsidence Contractors responsibilities, last reviewed 11 August AS/NZS : Part 2: Sanitary plumbing and drainage 6 H = Highly reactive clay sites that may experience high ground movement as a result of soil conditions and moisture changes E = Extremely reactive sites that may experience extreme amounts of ground movement as a result of soil conditions and moisture changes 7 Building Designers Association of Queensland Inc. & Building Services Authority document proprietary brand names have been blacked out

3 Case study: Slab heave caused by reactive soils 8 Slab heave is caused by reactive soils expanding and contracting when they absorb or desorb moisture. The source of moisture can be rainwater, damaged plumbing and drainage, ground water, poor surface drainage and garden irrigation. Causes of the ground drying out include tree roots, long dry seasons, ceasing irrigation and uneven shading of the ground. Variation in soil moisture under the slab is what causes slab heave. If the amount of moisture in the ground under the slab is uneven, movement in the house can be uneven. There are a number of instances where slab heave and the consequent damage it causes have led to significant legal action. In April 2016, the Full Court of the Victorian Court of Appeal upheld a decision made by the Victorian Civil and Administrative Appeals Tribunal against Metricon Homes Pty Ltd (Metricon). The case between Metricon and the homeowners who contracted them to build their home had been ongoing for six years. Shortly after moving into their new home the owners noticed structural faults. After repeated requests for rectification of the faults and a number of substandard fixes, the problems persisted. The homeowners eventually sought legal action against Metricon in an attempt to have their home reconstructed. In 2012 Slater and Gordon launched legal proceedings, and in 2014 a 10 day trial was heard. Slater and Gordon presented evidence to support that the home was suffering from severe structural failure, with extensive cracking both internally and externally due to slab heave. In December 2014, Metricon was ordered to pay for the demolition and re-construction of the home, as well as paying for removalists and rental accommodation. The decision was appealed and lost by Metricon in Since 2011 Slater and Gordon Lawyers have investigated the issue of slab heave and have been approached by more than 200 homeowners suffering from similar problems to those outlined in the case above. 8 Metricon loses appeal against couple over home packed with structural issues - Herald Sun, April 7, 2016 Homeowners win against one of Australia s biggest home builders - Slater and Gordon Lawyers website

4

5 Questions 1. Do you support maintaining the status quo? 2. Do you support amending the QPW code to adopt standardised solutions for the articulation of plumbing, drainage and stormwater for sites located in reactive and unstable ground conditions? Have your say Community and industry consultation will be held around the State and online from November You are invited to comment on the proposed reform options by: attending an industry or community engagement session details available at completing the online survey on the Queensland Government s Get Involved website: joining us in our Engagement Space at preparing a written response and sending it to: qldbuildingplan@hpw.qld.gov.au post: Queensland Building Plan Department of Housing and Public Works GPO Box 2457 CITY EAST BRISBANE QLD 4000

REACTIVE SOILS CAN BE VICIOUS. Des Grevell. Storm Plastics Pty Ltd

REACTIVE SOILS CAN BE VICIOUS. Des Grevell. Storm Plastics Pty Ltd REACTIVE SOILS CAN BE VICIOUS Paper Presented by: Des Grevell Authors: Des Grevell, State Manager Queensland, Marty Bennett, Master Plumber & Director, Storm Plastics Pty Ltd 34th Annual Qld Water Industry

More information

qbcc STRUCTURAL DAMAGE A SIMPLE HOW TO GUIDE TO PREVENTING TO YOUR HOME.

qbcc STRUCTURAL DAMAGE A SIMPLE HOW TO GUIDE TO PREVENTING TO YOUR HOME. A SIMPLE HOW TO GUIDE TO PREVENTING STRUCTURAL DAMAGE TO YOUR HOME. Plan your landscaping, lawns, gardens and foundation care to avoid ugly and costly problems. qbcc queensland building and construction

More information

PVC-U DWV Expanda Joints, Expansion Bends and Swivel Expansion Joints for gravity sewer applications

PVC-U DWV Expanda Joints, Expansion Bends and Swivel Expansion Joints for gravity sewer applications Date: 8 January 2013 To: From: RE: Technical Advisory Group Mohamed Yoosuf PVC-U DWV Expanda Joints, Expansion Bends and Swivel Expansion Joints for gravity sewer applications 1. Introduction This paper

More information

Building Application Pack

Building Application Pack Building Application Pack This following is designed to assist you in preparing the documentation needed to lodge a properly made building application for residential building work. Table of Contents The

More information

Frequently Asked Questions

Frequently Asked Questions Frequently Asked Questions Vacating the Dwelling 1) Q. How much notice will we be given to vacate our homes? A. The Project Manager will communicate to the Scheme Participant, not less than 30 days in

More information

OUR CAPABILITY STATEMENT

OUR CAPABILITY STATEMENT COMMERCIAL CIVIL ENGINEERING OUR CAPABILITY STATEMENT newlands.com.au QUALIFICATIONS AND CERTIFICATIONS OUR CERTIFIED QUALITY, HEALTH, SAFETY AND ENVIRONMENTAL MANAGEMENT SYSTEMS GIVE OUR CLIENTS THE CONFIDENCE

More information

SEWER OVERFLOWS. Information on plumbing blockages and wet weather overflows

SEWER OVERFLOWS. Information on plumbing blockages and wet weather overflows SEWER OVERFLOWS Information on plumbing blockages and wet weather overflows This guide has been designed to assist people who have experienced a sewer overflow. Queensland Urban Utilities provides water

More information

ON-SITE WASTEWATER MANAGEMENT POLICY

ON-SITE WASTEWATER MANAGEMENT POLICY ON-SITE WASTEWATER MANAGEMENT POLICY Responsible Department: Responsible Section: Responsible Officer: Planning and Development Strategy and Land Use Senior Health & Environmental Coordinator Objectives

More information

A HOME OWNER S GUIDE TO REBUILDING AFTER A FLOOD

A HOME OWNER S GUIDE TO REBUILDING AFTER A FLOOD A HOME OWNER S GUIDE TO REBUILDING AFTER A FLOOD March 2015 Steps to repair a house after a flood Below are the recommended steps to repair and restore houses after a flood event: ensure initial safety

More information

Power of Choice (PoC)

Power of Choice (PoC) Power of Choice (PoC) Frequently Asked Questions Why is the industry moving to digital meters? PoC reforms are a new set of rules being brought in by the National Electricity Regulator. These rules make

More information

DESIGN DOCUMENTATION REFERENCE GUIDE

DESIGN DOCUMENTATION REFERENCE GUIDE DESIGN DOCUMENTATION REFERENCE GUIDE Certification of Soils and Design Report - Obligations of Builder and Home Owner/Occupier The performance of the footings and slab or both is largely depended upon

More information

Summary. 1. The matter to be determined

Summary. 1. The matter to be determined Determination 2017/083 Regarding the refusal to issue a code compliance certificate for a house at 306 Pages Road, Timaru, and whether a producer statement is required for an on-site waste water treatment

More information

CPC Certificate IV in Building and Construction (Building)

CPC Certificate IV in Building and Construction (Building) CPC40110 - Certificate IV in Building and Construction (Building) Participants should be employed or seeking employment in the building and construction industry. This qualification is designed to meet

More information

Residential Sewer Backup Prevention Program

Residential Sewer Backup Prevention Program City of Wheaton Residential Sewer Backup Prevention Program Please Note: The City reserves the right to modify the policies, procedures and rules of this program or discontinue the program in its entirety

More information

Control of Random Cracking in Concrete Residential Pavements

Control of Random Cracking in Concrete Residential Pavements Control of Random Cracking in Concrete Residential Pavements Eric Lume (National Engineer, SRIA) and Mark Turner (Chairman, Committee BD-098 Pavements) Abstract: AS 3727.1 Pavements Part 1: Residential

More information

Transportation Report to SPC on Transportation and Transit 2017 April 19. ISC: UNRESTRICTED TT Page 1 of 7

Transportation Report to SPC on Transportation and Transit 2017 April 19. ISC: UNRESTRICTED TT Page 1 of 7 Page 1 of 7 EXECUTIVE SUMMARY The City of Calgary owns and maintains over 12,200 km of sidewalks, curbs and gutters with a current replacement value of $5.1 billion. The quality of new concrete and condition

More information

Private Side Sewer Inspections for Sources of Inflow & Infiltration Frequently Asked Questions

Private Side Sewer Inspections for Sources of Inflow & Infiltration Frequently Asked Questions Private Side Sewer Inspections for Sources of Inflow & Infiltration Frequently Asked Questions As of Oct. 1, 2010, Tacoma property owners are required to have a certified inspection of their private side

More information

1. INTRODUCTION 1.1 Contents of Engineering Specifications The Engineering Specifications contains the following sections:

1. INTRODUCTION 1.1 Contents of Engineering Specifications The Engineering Specifications contains the following sections: Schedule H to Bylaw 7452, Subdivision Bylaw Page 1 1. INTRODUCTION 1.1 Contents of Engineering Specifications 1.1.1 The Engineering Specifications contains the following sections: 1. Introduction 2. General

More information

Standard connections for water, sewerage and electricity supply

Standard connections for water, sewerage and electricity supply Pilbara electricity and water services Standard connections for water, sewerage and electricity supply Introduction Rio Tinto is committed to providing safe, reliable electricity, water and sewerage services,

More information

CONTRACT INFORMATION STATEMENT FOR NEW HOME CONSTRUCTION CONTRACTS

CONTRACT INFORMATION STATEMENT FOR NEW HOME CONSTRUCTION CONTRACTS CONTRACT INFORMATION STATEMENT FOR NEW HOME CONSTRUCTION CONTRACTS This document is the Contract Information Statement approved by the QBCC for use with contracts for the construction of a new home or

More information

Standard terms and conditions

Standard terms and conditions Standard terms and conditions Development Services For the provision of a water service (Water Supply, Wastewater and Drainage) Introduction Under Section 73(2)(a) of the Water Services Act 2012, landowners

More information

RAUPIANO PLUS ACOUSTIC PLUMBING AND DRAINAGE SYSTEM. Product. Scope. Building Regulations. Appraisal No. 809 [2013]

RAUPIANO PLUS ACOUSTIC PLUMBING AND DRAINAGE SYSTEM. Product. Scope. Building Regulations. Appraisal No. 809 [2013] RAUPIANO PLUS ACOUSTIC PLUMBING AND DRAINAGE Amended 20 July 2016 BRANZ Appraisals Technical Assessments of products for building and construction. REHAU Ltd 60B Cryers Road East Tamaki Auckland Tel: 09

More information

Eric Lume, National Engineer, SRIA Mark Turner, Chairman, BD-098 Pavements

Eric Lume, National Engineer, SRIA Mark Turner, Chairman, BD-098 Pavements Eric Lume, National Engineer, SRIA Mark Turner, Chairman, BD-098 Pavements A crack which does not occur at a planned location Term from ACI Standards Definition added to AS 3727.1 Pavements Part 1 Residential

More information

Flexible couplings. Housing Developments radiated further away from the CBD into questionable soils.

Flexible couplings. Housing Developments radiated further away from the CBD into questionable soils. Flexible couplings Housing Developments radiated further away from the CBD into questionable soils. ------DRAINAGE REQUIREMENTS AS 2870-2011 & AS 2032-2006. 1 THE MAIN PRODUCTS Housing Developments radiated

More information

CPC50210 Diploma of Building & Construction (Building)

CPC50210 Diploma of Building & Construction (Building) FACT SHEET [CPC50210 Diploma of Building & Construction (Building)] This program covers building theory and practices related to buildings. This program will provide you with the knowledge and managerial

More information

Queensland Building Plan. Response from Engineers Australia

Queensland Building Plan. Response from Engineers Australia Queensland Building Plan Response from Engineers Australia 28 February 2017 1 Engineers Australia 11 National Circuit, Barton ACT 2600 Tel: 02 6270 6555 Email: publicaffairs@engineersaustralia.org.au www.engineersaustralia.org.au

More information

Dispute regarding the venting of a branch drain using an air admittance valve to a building at 122 Remuera Road, Auckland

Dispute regarding the venting of a branch drain using an air admittance valve to a building at 122 Remuera Road, Auckland Determination 2008/32 Dispute regarding the venting of a branch drain using an air admittance valve to a building at 122 Remuera Road, Auckland 1. The matter to be determined 1.1 This is a determination

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 1546.2 Australian/New Zealand Standard On-site domestic wastewater treatment units Part 2: Waterless composting toilets This Joint Australian/New Zealand Standard was prepared by Joint Technical

More information

GRAYWATER SYSTEMS FOR RESIDENTIAL BUILDINGS

GRAYWATER SYSTEMS FOR RESIDENTIAL BUILDINGS City of Azusa Building & Safety Department 213 E. Foothill Blvd. Azusa, CA 91702-1395 (626) 812-5234 Fax: (626) 334-5464 GRAYWATER SYSTEMS FOR RESIDENTIAL BUILDINGS A. GRAYWATER SYSTEMS Under State regulations,

More information

PLANNING FOR DURABILITY AND LIFE CYCLE MAINTENANCE OF BUILDINGS DURING DESIGN

PLANNING FOR DURABILITY AND LIFE CYCLE MAINTENANCE OF BUILDINGS DURING DESIGN PLANNING FOR DURABILITY AND LIFE CYCLE MAINTENANCE OF BUILDINGS DURING DESIGN Paul Sandeford 1,*, 1 GHD Pty Ltd Materials Technology Group 145 Ann St, Brisbane, QLD, 4000, Australia*Email:paul.sandeford@ghd.com

More information

CERTIFYING DRAINLAYER

CERTIFYING DRAINLAYER Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 9198 REGISTRATION EXAMINATION, JUNE 2013 CERTIFYING DRAINLAYER INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time

More information

Review the section Preparing for work, then complete the following.

Review the section Preparing for work, then complete the following. CHAPTER 4: PLANNING THE LAYOUT FOR A RESIDENTIAL EXTERNAL SANITARY DRAINAGE SYSTEM 105 WORKSHEET 1 Student name: Enrolment year: Class code: Competency name/number: To be completed by teachers Satisfactory

More information

Retaining Wall System

Retaining Wall System Your local distributor Retaining Wall System Prestige & Quality Near Vertical Walls Do It Yourself No Concrete Footings Flexible - 90 o Corners, Steps, Straight or Curved Walls Commercial or Civil Walls

More information

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 1: Water services. Australian/New Zealand Standard. Superseding AS/NZS 3500.

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 1: Water services. Australian/New Zealand Standard. Superseding AS/NZS 3500. AS/NZS 3500.1:2015 Incorporating Amendment No. 1 Australian/New Zealand Standard Plumbing and drainage Part 1: Water services Superseding AS/NZS 3500.1:2003 AS/NZS 3500.1:2015 AS/NZS 3500.1:2015 This joint

More information

Strengthened Regulations

Strengthened Regulations Building Regulations review Strengthened Regulations The Department of Environment, Land, Water and Planning has identified a number of changes to the Building Regulations to improve consumer protection

More information

National Development Programs Manual

National Development Programs Manual National Development Programs Manual August 2014 V5 For further information, please contact: Diabetes Australia GPO Box 3156 Canberra ACT 2601 Fax: (02) 6230 1535 Email: admin@diabetesaustralia.com.au

More information

Foundation Design Report

Foundation Design Report Date : Project Job Number : : Local Authority : Site Classification (at time of Soil Test) : Foundation Design Report 2 June 2010 ES102149-B Brisbane City Council Class P/E The site classification is based

More information

PROCEDURES MANUAL INFRASTRUCTURE DEVELOPMENT

PROCEDURES MANUAL INFRASTRUCTURE DEVELOPMENT City of Shepherdsville Shepherdsville, Kentucky June 3, 2013 Table of Contents Page DEFINITIONS... 4 INTRODUCTION... 7 APPLICATION OF TECHNICAL MANUALS... 9 Public Roads... 9 Private Roads, Parking Lots,

More information

REPORT ON DOMESTIC BUILDING WORK

REPORT ON DOMESTIC BUILDING WORK justinspections building inspection service 1234 SAMPLE STREET CITY REPORT ON DOMESTIC BUILDING WORK Page 1 of 7 Pre-Purchase Inspections Owner-Builder Reports Quality Assurance Dispute Resolution Litigation

More information

Regarding the issuing of a building consent for the separation of surface water drainage to 39 and 39A Towai Street, Kohimarama, Auckland

Regarding the issuing of a building consent for the separation of surface water drainage to 39 and 39A Towai Street, Kohimarama, Auckland Determination 2013/001 1 Regarding the issuing of a building consent for the separation of surface water drainage to 39 and 39A Towai Street, Kohimarama, Auckland 1. The matters to be determined 1.1 This

More information

ADDRESS: 122 LIPSCOMBE ROAD, DECEPTION BAY, QLD,

ADDRESS: 122 LIPSCOMBE ROAD, DECEPTION BAY, QLD, WWW.TUFFOZYCONCRETESLEEPERS.COM.AU ADDRESS: 122 LIPSCOMBE ROAD, DECEPTION BAY, QLD, 4508 EMAIL: SALESTUFFOZYCONCRETESLEEPERS@HOTMAIL.COM PHONE: 0405233099 1.0 INTRODUCTION 1 2.0 DESIGN ASSUMPTIONS 1 2.1

More information

Building and renovating

Building and renovating Building and renovating Last updated: 20 November 2017 Summary This factsheet contains information about: the laws in Victoria on building and renovating the Victorian Building Authority owner-builders

More information

DEKS Industries Pty Ltd PRODUCT APPRAISAL REPORT No 1602

DEKS Industries Pty Ltd PRODUCT APPRAISAL REPORT No 1602 WSAA Product Appraisal PA1602 1 DEKS Industries Pty Ltd PRODUCT APPRAISAL REPORT No 1602 DEKS Shear Banded Flexible Couplings, DN 100 DN 250 AS/NZS 4327: 1995 Metal-banded flexible couplings for low pressure

More information

Appendix 3. POLICY & PROCEDURE No

Appendix 3. POLICY & PROCEDURE No DEPARTMENT OF PUBLIC WORKS DIVISION: ENGINEERING SERVICES SECTION: ADMINISTRATIVE PAGE NO: 1 OF 10 REVISION NO: 3 DATE: 1995 05 01 ESTABLISHED: 1986 03 03 Appendix 3 POLICY & PROCEDURE No. 2.3.1-020 TITLE:

More information

NCOSS Submission. Electricity Tariff reform in NSW. October 2015

NCOSS Submission. Electricity Tariff reform in NSW. October 2015 NCOSS Submission Electricity Tariff reform in NSW October 2015 Phone: 02 9211 2599 Email: info@ Suite 301, Level 3, 52 58 William St, Woolloomooloo NSW 2011 About NCOSS The NSW Council of Social Service

More information

BioFilm Termite Management System

BioFilm Termite Management System Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: PC Plastics Pty Ltd ABN: 81 164 968

More information

Builders Guide Pitt Town Water Builders Guide, March 2013

Builders Guide Pitt Town Water Builders Guide, March 2013 Builders Guide Table of Contents Welcome... 3 Contact us... 3 Pitt Town Water builders guide... 4 Safe and reliable... 4 Builders scope of work:... 4 Fees and charges... 4 Connection Fees... 5 Steps to

More information

FIX & WATERPROOFING INSPECTION REPORT & DEFECTS LIST. Lot 426 Sample Tce, Mernda

FIX & WATERPROOFING INSPECTION REPORT & DEFECTS LIST. Lot 426 Sample Tce, Mernda FIX & WATERPROOFING INSPECTION REPORT & DEFECTS LIST Lot 426 Sample Tce, Mernda Call us on: 0430 318 398 info@correctinspections.com.au www.correctinspections.com.au Postal Address: P.O. Box 22 Greensborough

More information

GRAYWATER STANDARD PLAN For Simple Residential System

GRAYWATER STANDARD PLAN For Simple Residential System (Based on 203 California Plumbing Code Chapter 6) Project Address: Permit Number: Scope: This Plan applies only to simple residential systems meeting all the following criteria: Graywater discharge is

More information

EPA Inquiry: Submission on behalf of Paper Australia Pty Ltd

EPA Inquiry: Submission on behalf of Paper Australia Pty Ltd Our reference AGPAPE16499-9101755/01 567 Collins Street, Melbourne VIC 3000 GPO Box 9925 Melbourne VIC Tel +61 396723000 Fax +61 396723010 www.corrs.com.au CORRS CHAMBERS WESTGARTH lawyers Sydney Melbourne

More information

Connecting to Sydney Water systems. This policy applies to all customers who want to connect to or disconnect from Sydney Water s systems.

Connecting to Sydney Water systems. This policy applies to all customers who want to connect to or disconnect from Sydney Water s systems. Policy Connecting to Sydney Water systems 1. Overview 1.1 At a glance This policy explains: the services we offer customers when customers need permission to connect and disconnect requirements for connecting

More information

THE PLUMBING CODE OF AUSTRALIA INFORMATION & MATERIALS FOR PLUMBING PRACTITIONERS

THE PLUMBING CODE OF AUSTRALIA INFORMATION & MATERIALS FOR PLUMBING PRACTITIONERS THE PLUMBING OF AUSTRALIA INFORMATION & MATERIALS FOR PLUMBING PRACTITIONERS A plumbing or drainage solution will comply with the Plumbing Code if it satisfies the Performance Requirements, which are the

More information

BUILDER S CONSTRUCTION SUPPLIES (Temporary in permanent position) REQUIREMENTS. March 2014

BUILDER S CONSTRUCTION SUPPLIES (Temporary in permanent position) REQUIREMENTS. March 2014 BUILDER S CONSTRUCTION SUPPLIES (Temporary in permanent position) REQUIREMENTS March 2014 Energy Safe Victoria (ESV) continues to receive complaints concerning defective builder s construction supplies.

More information

CUSTOMER CHARTER A SUMMARY OF YOUR RIGHTS AND RESPONSIBILITIES

CUSTOMER CHARTER A SUMMARY OF YOUR RIGHTS AND RESPONSIBILITIES CUSTOMER CHARTER A SUMMARY OF YOUR RIGHTS AND RESPONSIBILITIES At Queensland Urban Utilities, we are focused on providing accountable, efficient and innovative customer service. As our customers, you

More information

NSW Plumbing and Drainage Regulations. National Backflow Prevention Conference 28 th July 2016

NSW Plumbing and Drainage Regulations. National Backflow Prevention Conference 28 th July 2016 NSW Plumbing and Drainage Regulations National Backflow Prevention Conference 28 th July 2016 Key topics for discussion are; Plumbing and drainage regulation in NSW Consistent regulation approach Codes

More information

GRAY WATER SYSTEMS FOR RESIDENTIAL BUILDINGS

GRAY WATER SYSTEMS FOR RESIDENTIAL BUILDINGS INFORMATION BULLETIN / PUBLIC - PLUMBING CODE REFERENCE NO.: LAMC 94.1502.0 Effective: 01-01-2017 DOCUMENT NO.: P/PC 2017-012 Revised: Previously Issued As: P/PC 20014-012 GRAY WATER SYSTEMS FOR RESIDENTIAL

More information

KĀPITI COAST RAINWATER AND GREYWATER CODE OF PRACTICE. Table of Contents. Interpretation 2. Objective and Functional Statements 3.

KĀPITI COAST RAINWATER AND GREYWATER CODE OF PRACTICE. Table of Contents. Interpretation 2. Objective and Functional Statements 3. Appendix 2 KĀPITI COAST RAINWATER AND GREYWATER CODE OF PRACTICE Table of Contents Interpretation 2 Objective and Functional Statements 3 Definitions 3 Part 1 Sustainable water supplies for new dwellings

More information

GENERAL MAINTENANCE AND REPAIR

GENERAL MAINTENANCE AND REPAIR IS BASEMENT FLOODING A COMMON PROBLEM? Basement flooding is unfortunately a common occurrence in many parts of Canada. Basement flooding related insurance claims in Canada are estimated to be in the order

More information

SANITARY SEWER BACKUP

SANITARY SEWER BACKUP SANITARY SEWER BACKUP Causes & Prevention A. PURPOSE The purpose of this publication is twofold: 1. It provides homeowners with basic information on the causes of sanitary sewer backups. 2. It provides

More information

ATS :2010. Title: Pumps for general use in rainwater service. applications

ATS :2010. Title: Pumps for general use in rainwater service. applications ATS 5200.506:2010 Title: Pumps for general use in rainwater service applications ATS 5200 506 PUMPS January 24 2011.doc Page 1 CONTENTS PREFACE... 3 1SCOPE... 4 2APPLICATION... 4 3REFERENCED DOCUMENTS...

More information

SEPARATING WALLS CLASS 1A

SEPARATING WALLS CLASS 1A TECHNICAL DATA SHEET ISSUED BY TIMBER QUEENSLAND SEPARATING WALLS CLASS 1A (DUPLEXES, TOWNHOUSES, BUILDINGS ROW HOUSES, TERRACE HOUSES) 33 RECOMMENDED PRACTICE // AUGUST 2014 Fire and sound are important

More information

NEWSLETTER. This Edition

NEWSLETTER. This Edition NEWSLETTER 2011 Cover image: Knox Grammar School Great Hall and Aquatic Centre (Recently completed project, managed by EPM). Photo by Pixelmod Productions. This Edition The Cost of Counciling. Owner Builder

More information

ULDA Decision Notice

ULDA Decision Notice ULDA Decision Notice Site Address Bowen St, Roma Real property description Lot 142 SP250497 Type of approval UDA development approval subject to conditions Aspects of development Reconfiguring a Lot with

More information

KEVIN BURNS BUILDING INSPECTIONS REGISTERED BUILDER PRE-PURCHASE VISUAL STRUCTURAL INSPECTION REPORT No. 822

KEVIN BURNS BUILDING INSPECTIONS REGISTERED BUILDER PRE-PURCHASE VISUAL STRUCTURAL INSPECTION REPORT No. 822 KEVIN BURNS BUILDING INSPECTIONS REGISTERED BUILDER 6163 PRE-PURCHASE VISUAL STRUCTURAL INSPECTION REPORT No. 822 CLIENT: Talavera PROPERTY ADDRESS: Mindarie DATE: 20 April 2017 TIME: 9.00am WEATHER: Fine

More information

REPORT ON LEVEL 1 EARTHWORKS INSPECTION AND TESTING

REPORT ON LEVEL 1 EARTHWORKS INSPECTION AND TESTING 1 st December 2016 Project No. SGS/16/052 REPORT ON LEVEL 1 EARTHWORKS INSPECTION AND TESTING PROJECT: ELWOOD ESTATE STAGE 1, D AGUILAR DEVELOPER: URBEX SUPERINTENDENT: DMC QLD ENTERPRISES PTY LTD CONTRACTOR:

More information

qbcc queensland building and construction commission Standards & Tolerances Guide

qbcc queensland building and construction commission Standards & Tolerances Guide qbcc queensland building and construction commission Standards & Tolerances Guide Queensland May 2014 1 2 Foreword This Guide has been compiled in response to community and industry concerns that identified

More information

Certificate number: CM40175 Rev4

Certificate number: CM40175 Rev4 Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Type and/or use of product: HomeGuard Precision is a Termite

More information

Application for Building Consent and / or Project Information Memorandum Form 2 Section 33 of the Building Act 2004

Application for Building Consent and / or Project Information Memorandum Form 2 Section 33 of the Building Act 2004 37 Ayr Street, Ohakune 4625, New Zealand Telephone: 06 385 8364 Fax 06 385 8628 Email info@ruapehudc.govt.nz Website www.ruapehudc.govt.nz Application for Building Consent and / or Project Information

More information

KORDON TERMITE SYSTEM

KORDON TERMITE SYSTEM Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: Bayer CropScience Pty Ltd T/A Bayer

More information

PLAN CHECK CORRECTION SHEET FOR NON-POTABLE RAINWATER CATCHMENT SYSTEMS 2017 LAPC

PLAN CHECK CORRECTION SHEET FOR NON-POTABLE RAINWATER CATCHMENT SYSTEMS 2017 LAPC PLAN CHECK CORRECTION SHEET FOR NON-POTABLE RAINWATER CATCHMENT SYSTEMS 2017 LAPC This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes

More information

CIVIL ENGINEER. Position Description. 3, 200 Creek Street, QLD 4000 PO Box 99, Spring Hill QLD 4004

CIVIL ENGINEER. Position Description. 3, 200 Creek Street, QLD 4000 PO Box 99, Spring Hill QLD 4004 CIVIL ENGINEER Position Description 3, 200 Creek Street, QLD 4000 PO Box 99, Spring Hill QLD 4004 Our Vision The company vision is to be recognised nationally and internationally as a leading provider

More information

Design flow = PDWF + GWI + RDI

Design flow = PDWF + GWI + RDI WSA 02 2014 3.1 1 Appendix C C1 GENERAL APPENDIX C FLOW ESTIMATION FOR UNDEVELOPED AREAS The use of this Appendix requires Water Agency approval. Design flow estimates are required for designing pipe networks

More information

Application for Project Information Memorandum and/or Building Consent (Form 2) Section 33 or section 45, Building Act 2004

Application for Project Information Memorandum and/or Building Consent (Form 2) Section 33 or section 45, Building Act 2004 Application for Project Information Memorandum and/or Building Consent (Form 2) Section 33 or section 45, Building Act 2004 For Official use Project Date Received: Items marked * are mandatory for all

More information

1 EnviroStats Statistics Canada.

1 EnviroStats Statistics Canada. Greenest City Vancouver Submission to the Water Working Group by the POLIS Project on Ecological Governance June 18 th, 2009 What does a sustainable water community look like? What could it look like in

More information

Site investigation and preparation

Site investigation and preparation Site investigation and preparation Introduction The characteristics of a site determine many aspects of a building's design. It is necessary to analyse or evaluate the land to be built on to identify the

More information

CIC Guidelines Preliminary Design

CIC Guidelines Preliminary Design Version 1.0 / August 2016 Stage 3 of 8 Approval: Of previous stage, design documentation, updated programme and cost plan. List matters from previous stage to be addressed in current stage. Documentation:

More information

BUILDING BETTER BUILDINGS BY AVOIDING DEFECTS. Geoffrey Carter 1 and Crina Oltean-Dumbrava 2. 1 The Nottingham Trent University, UK

BUILDING BETTER BUILDINGS BY AVOIDING DEFECTS. Geoffrey Carter 1 and Crina Oltean-Dumbrava 2. 1 The Nottingham Trent University, UK CIB W89 BEIJING INTERNATIONAL CONFERENCE, 21-24 OCTOBER, 1996 BUILDING BETTER BUILDINGS BY AVOIDING DEFECTS Geoffrey Carter 1 and Crina Oltean-Dumbrava 2 1 The Nottingham Trent University, UK 2 University

More information

DEVELOPMENT PERMIT APPLICATION COMMERCIAL

DEVELOPMENT PERMIT APPLICATION COMMERCIAL DEVELOPMENT PERMIT APPLICATION COMMERCIAL DEVELOPMENT DIVISION Department of Unincorporated Area Services 600 Commerce Street 7 th Floor, Suite 750, Dallas Texas 75202 Main: 214.653.6565 Fax: 214.653.6464

More information

CURRICULUM VITAE. TELEPHONE: Mobile Senior Building Consultant Integrated Building Consultancy

CURRICULUM VITAE. TELEPHONE: Mobile Senior Building Consultant Integrated Building Consultancy CURRICULUM VITAE NAME: Scott Whitton DATE OF BIRTH: 10 th November 1975 ADDRESS: P O Box 7769 Baulkham Hills BC NSW 2153 TELEPHONE: 8814 5999 Mobile 0401 173 716 FACSIMILE: 8814 5899 EMAIL: scott@ibc.net.au

More information

Galintel RETAINING WALL POST. Installation Guide. The Galintel brand is proudly owned by

Galintel RETAINING WALL POST. Installation Guide. The Galintel brand is proudly owned by Galintel RETAINING WALL POST Installation Guide The Galintel brand is proudly owned by Contents Page No. 01 Introduction 03 02 Products 04 03 Installation 06 01 INTRODUCTION Galintel THE TRUSTED NAME IN

More information

TOWN OF WINDSOR CONSTRUCTION GUIDELINES

TOWN OF WINDSOR CONSTRUCTION GUIDELINES TOWN OF WINDSOR CONSTRUCTION GUIDELINES 1 CONSTRUCTION GUIDELINES Contents Certificate of Occupancy SAFEbuilt Utilities/Construction Water Fire Hydrant Meters Water & Sewer Service Standards Sump Pump

More information

AFA Submission Independent Review of the Financial Ombudsman Service

AFA Submission Independent Review of the Financial Ombudsman Service 11 October 2013 Mr Phil Khoury Cameronralph Navigator Pty Ltd Email: phil@cameronralph.com.au Dear Mr Khoury, AFA Submission Independent Review of the Financial Ombudsman Service The Association of Financial

More information

SMARTER ENGINEERING SOLUTIONS. For Residential and Commercial. Since 1991.

SMARTER ENGINEERING SOLUTIONS. For Residential and Commercial. Since 1991. SMARTER ENGINEERING SOLUTIONS. For Residential and Commercial. Since 1991. SETTING THE BENCHMARK FOR ENGINEERING EXCELLENCE. STA Consulting Engineers is one of Australia s most trusted engineering companies

More information

Superwall / Hydrowall System

Superwall / Hydrowall System Certification Body: THIS TO CERTIFY THAT Certificate number: CM40085 ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Type

More information

Building in a Saline Environment

Building in a Saline Environment Building in a Saline Environment Urban Salinity Prevention Building in a Saline Environment This advice is of a general nature and detailed advice should be sought from a certified structural engineer.

More information

Urban Revitalization Plan For Responsible and Sustainable Growth and Development City of Adel, Iowa

Urban Revitalization Plan For Responsible and Sustainable Growth and Development City of Adel, Iowa Urban Revitalization Plan For Responsible and Sustainable Growth and Development City of Adel, Iowa Residential Tax Abatement Program Application Applicant Name (Print) Address / City / State Phone Email

More information

Terms and Conditions for Listing a PV Module on CEC Approved Product List

Terms and Conditions for Listing a PV Module on CEC Approved Product List Terms and Conditions for Listing a PV Module on CEC Approved Product List Definitions: Applicant means the company or individual, applying to the CEC to have products included on the CEC list of compliant

More information

C231 Subsoil and Foundation Drains

C231 Subsoil and Foundation Drains CONSTRUCTION SPECIFICATION FOR DEVELOPMENTS AND SUBDIVISIONS C231 Subsoil and Foundation Drains Tamworth Regional Council Page :1 TABLE OF CONTENTS CLAUSE CONTENTS PAGE ORIGIN OF DOCUMENT, COPYRIGHT...

More information

Pre Treat for Termites without hand spraying chemicals and Re Apply Treatment safely in the future

Pre Treat for Termites without hand spraying chemicals and Re Apply Treatment safely in the future A.B.N. 39 050 495 399 Pre Treat for Termites without hand spraying chemicals and Re Apply Treatment safely in the future Australian Patent 626742 Altis Pty Ltd reserves the right to change at any time

More information

Aurizon Network Pty Ltd Board Charter

Aurizon Network Pty Ltd Board Charter Aurizon Network Pty Ltd Board Charter Adopted by the Board: 6 October 2010 Last reviewed by the Board: 9 August 2018 Aurizon Holdings Limited (the Company) ACN 146 335 622 Level 8, 900 Ann Street Fortitude

More information

CIVILTEST ALBURY WODONGA

CIVILTEST ALBURY WODONGA CIVILTEST ALBURY WODONGA Soils Engineering Laboratory 16 Kane Road, Wodonga - Postal Address P.O Box 876, Wodonga 3689 Telephone 0260 243960 Summit Group C/- EDM Group 99 Hume Street Wodonga, Vic, 3690

More information

MAINSTREAMING SOLAR HOT WATER

MAINSTREAMING SOLAR HOT WATER MAINSTREAMING SOLAR HOT WATER Ken Guthrie, Robert Hines, Sonja Ott, Katrina Woolfe Sustainability Victoria Level 28, 50 Lonsdale Street, Melbourne 3000 ken.guthrie@sustainability.vic.gov.au ABSTRACT Water

More information

Table of Contents. Surfaces by Hynes Laminate Flooring 25 Year Warranty. Laminate Warranty Conditions

Table of Contents. Surfaces by Hynes Laminate Flooring 25 Year Warranty. Laminate Warranty Conditions Table of Contents Surfaces by Hynes Laminate Flooring 25 Year Warranty... 1 This warranty is offered under the following conditions:... 2 Installation... 2 Wet Areas... 2 Indoor Use Only... 2 Maintenance...

More information

/552 Level 3 Constructing the Build Environment (Construction) Version 1.0 November Sample Questions Mark Scheme

/552 Level 3 Constructing the Build Environment (Construction) Version 1.0 November Sample Questions Mark Scheme 6720-052/552 Level 3 Constructing the Build Environment (Construction) Version 1.0 November 2017 Sample Questions Mark Scheme 1 State the purpose of the following components of a domestic electrical system.

More information

Murrumba State Secondary College Guidance and Careers Matters

Murrumba State Secondary College Guidance and Careers Matters Careers Information Murrumba State Secondary College Guidance and Careers Matters This edition of Guidance and Careers Matters has information about Women in Defence, Aviation Australia, Starfish. Careers

More information

WHICH WAY IS IT MOVING?

WHICH WAY IS IT MOVING? WHICH WAY IS IT MOVING? Guidelines for Diagnosing Heave, Subsidence and Settlement Authors: Presented by: Presented to : Ron Kelm, P.E., and Nicole Wylie, P.E. Forensic Engineers Inc. Ron Kelm, P.E. Presented

More information

Refrigerated Warehouse & Transport Association of Australia Chain of Responsibility Code of Practice

Refrigerated Warehouse & Transport Association of Australia Chain of Responsibility Code of Practice Refrigerated Warehouse & Transport Association of Australia Chain of Responsibility Code of Practice PREPARED BY: Refrigerated Warehouse & Transport Association of Australia Ltd AUTHORISED BY: Paul Fleiszig

More information

Christchurch City Council Environmental Policy & Approvals Unit. Memorandum. STEVE McCARTHY (Environmental Policy & Approvals Manager)

Christchurch City Council Environmental Policy & Approvals Unit. Memorandum. STEVE McCARTHY (Environmental Policy & Approvals Manager) Christchurch City Council Environmental Policy & Approvals Unit Memorandum Date: 13 APRIL 2010 From: STEVE McCARTHY (Environmental Policy & Approvals Manager) To: CHAIRPERSON AND MEMBERS OF THE SUBMISSIONS

More information

LOT GRADING GUIDELINES FOR COMMERCIAL, INDUSTRIAL, INSTITUTIONAL, MEDIUM AND HIGH DENSITY RESIDENTIAL PROPERTIES

LOT GRADING GUIDELINES FOR COMMERCIAL, INDUSTRIAL, INSTITUTIONAL, MEDIUM AND HIGH DENSITY RESIDENTIAL PROPERTIES LOT GRADING GUIDELINES FOR COMMERCIAL, INDUSTRIAL, INSTITUTIONAL, MEDIUM AND HIGH DENSITY RESIDENTIAL PROPERTIES Contents COMMERCIAL, INDUSTRIAL, INSTITUTIONAL, MEDIUM AND HIGH DENSITY... 1 RESIDENTIAL

More information

IMPLEMENTING WATER REFORM IN QUEENSLAND, AUSTRALIA CASE # 24

IMPLEMENTING WATER REFORM IN QUEENSLAND, AUSTRALIA CASE # 24 IMPLEMENTING WATER REFORM IN QUEENSLAND, AUSTRALIA CASE # 24 ABSTRACT Description This case describes a series of legislative and policy developments which were undertaken to reform the water sector in

More information