COMPANY PROFILE. under effective guidance of highly experienced and integrated top management.
|
|
- Rolf Patrick
- 6 years ago
- Views:
Transcription
1 COMPANY PROFILE Ganges group is a multi faced professionally managed organization, dealing in different fields of manufacturing. The group has interest & strong presence in di ersified field like solar turnkey diversified t rnke projects, projects telecom turnkey t rnke projects, projects steel tubes t bes & pipes, heavy fabrication, roller flour mills, bread manufacturing. The Group turnover is over 1000 cr. with employee strength of over The Group is thinking of newer Horizon and our working harmoniously to achieve excellence under effective guidance of highly experienced and integrated top management. Ganges Internationale (P) Ltd is Primarily a Construction Company, having interest in design, manufacturing and erection of Pre Engineered Buildings (PEB), Solar panel mounting structure, telecom structure. The Company have two plants one at Pondicherry & another at Raipur with modern equipments, having facilities for manufacturing complete range of PEB, solar panel mounting structure & telecom structure.
2 We are leading manufacturers of Pre Engineered Buildings. We are equipped with latest machinery and equipments. We have in house manufacturing capabilities to fabricate all type of structures. We have indigenously developed and manufactured these products under stringent quality checks at every stage of production to achieve best performance standards. We are setting up one more facility in Raipur with the capacity for Production of MT of PEB per Annum. Production will be started by the year end. Objectives: Customer satisfaction Maintain Highest Quality Standards Maintain pace with Technology Advent Offering a Solution to every need under one roof Turnkey Responsibility: Single source integrated solutions Design Engineering Procurement Supply & Installation Our core values are: Integrity Commitment Excellence
3 Pre Engineered Building Components: Primary Members: Columns, Rafters, Frames, (Hot Rolled / Built up Sections) Bracings Purlins, Purlins Girts, Girts (Cold formed Sections) Roof & Wall Secondary Members Bracings, Cladding Roofing, Cladding, PU Sandwitched panels, Flashings (Ridge, Gutter etc) Accessories: - Anchor Bolts, Fasteners, Connectors. Optional Extra: Fascia, Canopies, louvers, Skylights, Crane Gantry, false Ceilings, Mezzanine, Turbovents. Applications of Pre Engineered Buildings: Warehouses Factories Cold Stores Offices, Schools, Hospitals, Site Offices Gas Stations, Bus Shelters, Car Parks Commercial C i lc Complexes, l Sh Shopping i M Malls ll Aircraft Hangars Sports and other recreational facilities Metro / Railway Stations
4 DETAILS OF DESIGNING AND DRAFTING FACILITIES Applicable Codes:Loads are applied in accordance with: The 2005 Edition of Low Rise Building System Manual Metal Building Manufacturers Association (MBMA) p sections are designed g in accordance with: Hot rolled and Built up Manual of Steel Construction, 9th Edition American Institute of Steel Construction (AISC) Cold-formed members are designed in accordance with: Edition of Cold formed Steel Design Manual American Iron and Steel Institute (AISI) Welding is applied in accordance with: American Welding Society (AWS D1.1.98) Structural Welding Code Steel
5 Loads on all buildings are applied in accordance with: IS-875 (Part-I) 1987: Code of Practice for Design Dead Loads for Building and Structures. IS-875 (Part-II) 1987: Code of Practice for Design Imposed Loads for Building and Structures. IS-875 (Part-III) 1987: Code of Practice for Design Wind Loads for Building and Structures. IS-1893 (Part-I) 2002: Criteria for Earthquake Resistance Design of Structures. Design of prismatic Hot Rolled and Built up sections is in accordance with: IS-800 ((1984): ) Code of Practice for general g Construction in Steel. Cold Formed members are designed in accordance with: IS-801 (1975): Code of Practice for use of Cold Formed Light Gauge Steel Structure. Welding is applied in accordance with: Structure Steel Welding Code of American Welding Society (AWS D1.1.98) IS-816 (1969): Code of Practice for use of Metal Arc Welding for general construction in steel. l DESIGN FACILITY: IN HOUSE. CODES FOLLOWED, IS / ASIC AND AS PER MBMA. Auto Cad is being used for Designing/Drafting.
6 Plant Details Plant No 1: Pondicherry Area: 18 Acre Plant No 2: Raipur Area: 5 Acre Ganges Purlins Advantage osaving upto % 40% in weight and 20% in cost when compared to hot rolled purlins. otruss spacing can be increased, hence less numbers of trusses columns and foundation work resulting in further economy. othe purlins are supplied in required lengths with pre-punched holes. hence, reduction in constrained time and cost in fabrication & erection and no wastage. opurline erection is easier than oyhers. oclose tolerances on sectional dimensions due to process of cold roll forming. olow o o transportation t a spo tat o cost due to reduced educed weight. ohigh versatility, durability and uniform quality. Plant No 3: Raipur Area: 23 Acre Under Construction
7 Types of Frames
8 Roofing and Wall Cladding GANGES HI RIB PROFILE Hi Rib profile is developed to provide GANGES Hi Rib scientific solution for roof & side walls of industrial as well as commercial buildings. GANGES Hi Rib is provided with a precisely engineered wide Rib & flute design to ensure wide spanning & quick recovery after being subjected to excessive load. GANGES KLIPPON GANGES Klippon is stiffened trapezoidal profile with wide spanning capability. it is suitable for roofing fi application li i on very llong roofs f d down to 2 pitch. its bold profile and broad flat outline makes a strong and striking appearance. GANGES SS 2000 This is field seamed system that combines a slim rib with exceptional uplift resistance. This panel has been designed to withstand the most rigorous conditions for data details and fixing procedures, please refer to GANGES Metal Roofing & SSR catalogues.
9 Building Accessories Sliding Doors GANGES standard double/single sliding doors are of size 4.0 X 4.0 M. We are also equipped to offer any size up to 8.0 X 6.0 M as per customers' requirements. Louvers GANGES standard louvers are of size 2.0 M long X 0.60 M wide. Sky Lights and Wall Lights GANGES standard sky lights/wall lights come in two variations, either in FRP or Polycarbonate of 1.5 mm thi k thickness and d size i M X M. M
10 Building Accessories Ridge Ventilators GANGES standard ridge ventilators are of 0.3 M throat width and can be supplied either continuous or in modules of 3.0 M length. Roof Jacks & Curbs Roof jacks are available in opening sizes from mm dia and roof curbs are available in 900 mm square, and are used for fixing powered ventilators supplied by others.
11 PLANT AND MACHINERY
12 LIST OF PLANT AND MACHINERY
13
14
15
16 THANKS For Ganges Internationale Pvt. Ltd Corp Office: B 36,Lawrence Road Industrial Area New Delhi No Tel No Fax No Mob No E mail peb@gangesintl.com Web: g g
Technical specifications Prefab Steel Canopy
Canopy Structure: Technical specifications Prefab Steel Canopy Design fabrication and installation of pre-engineered / pre- fabricated steel canopy as per the following specification: The canopy steel
More informationPRE-ENGINEERED METAL BUILDING SYSTEM
PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,
More informationSECTION METAL BUILDING SYSTEMS
SECTION 13 3419 PART 1 GENERAL 1.01 SECTION INCLUDES A. Manufacturer-engineered, shop-fabricated structural steel building frame. B. Insulated Metal wall and roof panels including gutters and downspouts.
More informationProfessional Engineering Services. The Brand of Choice
The Brand of Choice Nucor Building Systems, a division of Nucor Corporation, is one of the most flexible and diverse building manufacturers in operation today. Nucor Corporation is a Fortune 500 Company,
More informationSECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM
SECTION 13 34 21 - STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. The structural retrofit roof sub-framing system will provide support for a new metal roofing system constructed
More informationSIERRA MODEL 12 X 24 SPECIFICATIONS
SIERRA MODEL 12 X 24 SPECIFICATIONS Dimensions: Roof Dimensions 12-0 x 24-0 Column Dimensions (center to center) 9-0 x 21-0 Minimum Clearance 8-0 Shed Roof 1:12 pitch Square Feet Under Roof 288 Columns
More informationMETAL BUILDING SYSTEM SPECIFICATIONS
METAL BUILDING SYSTEM SPECIFICATIONS 1. GENERAL 1.1. SCOPE 1.1.1. These specifications apply to metal buildings systems as engineered, designed, and fabricated by Tyler Building Systems, L.P. ( Tyler ).
More informationPIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components
Central Texas Largest Distributor Structural Steel, Pipe and Metal Building Components PIPE Waco Location P.O. Box 154485 913 South Loop Dr. Waco Texas 76705 Local - 254-754-2611 Bryan Location 9401 E.
More informationBuilt to Last a Lifetime
Built to Last a Lifetime Welcome to Lincoln 2 This brochure will introduce you to Lincoln Steel Buildings from the ground up starting with the framing of the building all the way to the roof and finally
More informationProspective Construction Systems for Mass Housing
Prospective Construction Systems for Mass Housing TECHNOLOGY PROFILE Light Gauge Steel Framed Structures (LGSF) Building Materials & Technology Promotion Council Ministry of Housing & Urban Poverty Alleviation
More informationm sys.co ild u lb a d.jin w w w A Brief Introduction
A Brief Introduction GROUP JINDAL MEDITECH JINDAL PADDING JINDAL BUILTECH SARVPRIYA TUBES JINDAL BUILDSYS JINDAL NIRYAT JINDAL MECTEC JINDAL SOFTITALIA SARVPRIYA EXPORTS CMD Sh. Madan Jindal Sh. Madan
More informationPRE-ENGINEERED METAL BUILDINGS
PRE-ENGINEERED METAL BUILDINGS CONTENTS Section 1: General Section 2: Structural Steel Design Section 3: Basic Material Specifications Section 4: Structural Framing Section 5: Roof and Wall Covering Section
More informationDESIGN CRITERIA. Allowable Stress Design (ASD) AISC-1999.
DESIGN CRITERIA 1. INTRODUCTION This appendix summarizes the codes, standards, criteria, and practices that are generally used in the design and construction structural engineering system for the Sarker
More informationMetal Building Systems Performance Guide Specification
October 2012 Metal Building Systems Performance Guide Specification METAL BUILDING MANUFACTURERS ASSOCIATION 1300 Sumner Avenue Cleveland, Ohio 44115 Performance Guide Specification This Guide Specification
More informationBEARING METAL STUD FRAMING
L-1 Section 05410 Long Form Specification LOAD BEARING METAL STUD FRAMING This section includes axially loaded steel studs, with unique slotted top channels, usually of 0.91, 1.2 and 1.5 mm (16, 18, or
More informationThe Olympia Difference
The Olympia Difference Valued Customer, Thank you for choosing Olympia Steel Buildings as the solution to your building needs. You can be confident that the Olympia team of professionals will provide you
More informationGUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM
- --- -- ----..-------~------------------------------------ GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION 07415 REROOFING ADJUSTABLE FRAMING SYSTEM PART 1 - GENERAL 1.01 SCOPE A.
More informationYOU BRING THE PASSION, WE'LL BRING THE FLAT & GABLE SHEDS DOMESTIC RURAL INDUSTRIAL
YOU BRING THE PASSION, WE'LL BRING THE FLAT & GABLE SHEDS DOMESTIC RURAL INDUSTRIAL FLAT & GABLE ROOF SHEDS GABLE ROOF SHEDS Form and function come together in the classic shape of the Gable Roof Shed.
More informationPOST FRAME BUILDING STANDARDS
CASS COUNTY, MISSOURI BUILDING CODES, ENVIRONMENTAL HEALTH AND ZONING DEPARTMENT 30508 S. West Outer Road, Harrisonville, MO 64701 P- (816) 380-8134 F- (816) 380-8130 POST FRAME BUILDING STANDARDS 201.3
More informationContents DESIGNER S STRUCTURAL PRODUCTS GUIDE. Tegral Purlins & Rails
DESIGNER S STRUCTURAL PRODUCTS GUIDE Introduction Contents Tegral Purlins & Rails Zeta Purlins & Rails Zeta Purlins page 8 Zeta Rails page 15 Zeta Purlin & Rail Cleats page 22 Zeta 2 Purlins & Rails Zeta
More informationProject s fiche INOV. Frisomat Case study project's fiche INOV
Project s fiche INOV Clear Flatro building 49 metres long The Flatro industrial building in Villers-le-Bouillet measures 15 metres by 49 metres and is 6 metres high. The building rests on concrete plinths
More informationDUGOUT MODEL (4 POST) 10 x 24 SPECIFICATIONS
DUGOUT MODEL (4 POST) 10 x 24 SPECIFICATIONS Dimensions: Roof Dimensions 10-0 x 24 Column Dimensions (center to center) 6-7 x 22-9 Minimum Clearance 7-6 Minimum Clearance @ Front ±9-2 Roof Pitch 2:12 pitch
More informationJORACK. Storage Solutions from Design to Installations.
JORACK Storage Solutions from Design to Installations Profile Jorack, the range of Industrial racks from Josts is a perfect storage solution for all types of items, as the design allows the span to be
More informationDIVISION XIII - SPECIAL CONSTRUCTION
DIVISION XIII - SPECIAL CONSTRUCTION SECTION 13120 - PRE-ENGINEERED METAL BUILDING SYSTEM (RAILROAD EQUIPMENT ENCLOSURE BUILDING) PART 1 - GENERAL 1.01 WORK INCLUDED A. Work of this section covers the
More informationA. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code.
SECTION 05400 COLD-FORMED METAL FRAMING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification
More informationSTATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014
STATE STRUCTION FUND DIRECTIVE 5-1 Issue date: October 2014 STRUCTURAL STEEL 1. General: It is the Fund's policy that the design of the structural steel is the prime responsibility of the project's Structural
More informationGeneral. 2. Design. 3. Anchor Bolts And Foundations. 4. Drawings. 5. Structural Framing. 6. Roof Covering Nucor Classic Roof Panel
The following Nucor Building Systems Specification Guide provides the owner or design professional a detailed description of all standard Nucor Building Systems (NBS) products. This guide is designed to
More informationComparison of Design Procedures for Pre Engineering Buildings (PEB): A Case Study
Comparison of Design Procedures for Pre Engineering Buildings (PEB): A Case Study G. Sai Kiran, A. Kailasa Rao, R. Pradeep Kumar Abstract In recent years, the introduction of Pre Engineered Building (PEB)
More informationSECTION PLATE CONNECTED WOOD TRUSSES
SECTION 06173 PLATE CONNECTED WOOD TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shop fabricated wood trusses for roof and floor framing. 2. Bridging, bracing, and anchorage. B. Related Sections:
More informationWHAT IS CANTILEVER RACK?
PRODUCT INFORMATION WHAT IS CANTILEVER RACK? 2946 Larimer St. Denver, CO 80205 303-295-1100 / 800-373-7693 FAX 303-295-2464 Email info@snyderequipment.com www.snyderequipment.com MODERN EQUIPMENT COMPANY,
More informationSECTION PRE-ENGINEERED MEMBRANE STRUCTURE
SECTION 13125 PART 1 - GENERAL 1.1 SUMMARY A. Section includes the design, engineering, fabrication and erection of a frame-supported, tensilemembrane structure complete with entrance and exit doors and
More informationDIGNUS INFRA PRIVATE LTD.
DIGNUS INFRA PRIVATE LTD. (AN ISO 9001 : 2008 CERTIFIED) Registered & Corporate Office : #3338, 2nd Floor, Sector 23-D, Chandigarh - 160 023. Telefax : +91-172-5035612 Delhi NCR Office : B-19, 2nd Floor,
More informationYour full service light gauge steel manufacturer
Your full service light gauge steel manufacturer In addition to roof trusses, Superior Truss also supplies: q Light gauge steel floor trusses with metal decking and/or plywood sheathing q Light gauge steel
More informationGood ideas. for your new building. BUILDINGS. Ideas become reality
Good ideas for your new building. BUILDINGS Your creativity. Our experience. The design of a modern building is born out of a need to fulfill particular requirements economically together with a certain
More informationThe 2013 AISI Cold-Formed Steel Design Manual
Missouri University of Science and Technology Scholars' Mine International Specialty Conference on Cold- Formed Steel Structures (2014) - 22nd International Specialty Conference on Cold-Formed Steel Structures
More informationCANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE
CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural cantilever rack design. In addition, it is
More informationxiii Preface to the Fifth Edition Preface to the Second Edition Factors for Conversion to SI Units of
Structural Steel Designer's Handbook Table Of Contents: Contributors xiii Preface to the Fifth Edition xv Preface to the Second Edition xvii Factors for Conversion to SI Units of xix Measurement Chapter
More informationSECTION COLD-FORMED METAL FRAMING
SECTION 05400 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work of this Section shall include all materials and installation necessary to provide all cold formed metal framing. B. This Section includes:
More informationSTEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN
STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD AND TRACK FOR DRYWALL PARTITIONS TAKE ADVANTAGE OF THE SAVINGS IN TIME
More informationHelioFix Solar mounting Systems
HelioFix Solar mounting Systems Industrial Roof Flat Roof Ground Mount Carport Mount Structural Analysis Analysis of wind loads and dead loads using STAAD Pro. 2D drafts of General Arrangement and Structural
More informationSECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:
SECTION 10501 PERSONNEL DUTY LOCKERS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 specifications
More informationSteelway Building Systems. Product Specifications Guide
Steelway Building Systems Product Specifications Table of Contents 1.0 Scope... 2 2.0 Design Standards... 3 3.0 Product Standards... 3 3.1 Plate, Coil and Hot-Rolled... 3 3.2 Bolts and Fasteners... 3 4.0
More informationA. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.
SECTION 10530 - EXTRUDED ALUMINUM WALKWAY COVERS PART I - GENERAL.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division
More informationA. Access doors and frames are part of an access door and frame allowance.
SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationgarages, sheds & carports
garages, sheds & carports thank you for enquiring about Rainbow Building Solutions exceptional range of products. Please take a moment to look through this brochure. If you have any questions please don
More informationRS24-10 Single-Section Skylight System
INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980
More informationOur buildings are manufactured entirely in the United States with a 25 year steel mill backed guarantee.
Our buildings are manufactured entirely in the United States with a 25 year steel mill backed guarantee. Olympia is recognized as one of the industry leaders in providing superior quality, service, and
More informationFabrication for the rail industry
Fabrication for the rail industry WEC Group is a leading force in providing innovative design, fabrication & installation services to the rail industry. Our unique approach has led to us providing innovative
More informationGuidance document GD 20 April 2015 amended May 2017 GUIDANCE DOCUMENT ON SERVICEABILITY STATES AND DEFLECTION CRITERIA
Guidance document GD 20 April 2015 amended May 2017 GUIDANCE DOCUMENT ON SERVICEABILITY STATES AND DEFLECTION CRITERIA 1 INTRODUCTION The Metal Cladding and Roofing Manufacturers Association had noticed
More informationSECTION HVAC GRAVITY VENTILATORS
SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationA. Pre-engineered, pre-finished extruded aluminum Pavilions.
10 73 00 SECTION Pavilions PART 1 GENERAL 1.1 SECTION INCLUDES A. Pre-engineered, pre-finished extruded aluminum Pavilions. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and Accessories. B. Section
More informationGERI INDUSTRIAL ESTATE. T: , F: E:
NICOLAIDES & KOUNTOURIS Metal Company Ltd GERI INDUSTRIAL ESTATE P.O.Box: 12665, 2251 Nicosia Cyprus T: +357-22482000, F: +357-22485380 E: nkm@cytanet.com.cy, www.nkmetal.com.cy Effective Support for Efficient
More informationThe Smart Roof People
GRS Corporate The Smart Roof People Talk to THE SMART ROOF PEOPLE Visit www.globalroofs.co.za or email info@globalroofs.co.za GRS Corporate GRS Corporate 07/17 Total Roofing Solutions From GRS Global Roofing
More informationmounting systems applications overview
mounting systems applications overview catalogue version January 2015 tritec mounting systems: overview of applications i. pitched roof: roof-top 1. Tiles, shingles and corrugated panels 1.1 TRI-STAND
More informationCustom Daylighting Structures
METAL FRAMED SKYLIGHTS Product 086300 CANOPIES 107316 TRANSLUCENT WALLS 084500 wascoskylights.com ENLIGHTENED LIVING Custom Daylighting Structures WASCOSKYLIGHTS.COM We ll See Your Vision Through Wasco
More informationEngineered Roof Solutions
Engineered Roof Solutions VARCO PRUDEN BUILDINGS From Varco Pruden Retrofit and Reroofing LONG-TERM ROOF SOLUTIONS Slope Build-Up Solution Re-Slope for Water Management Before After Metal Over-Metal-Solution
More informationPennar Engineered Building Systems Limited. Investor Presentation Q2FY16
Pennar Engineered Building Systems Limited Investor Presentation Q2FY16 Disclaimer This presentation contains forward looking statements including, but without limitation, statements relating to the implementation
More informationEverything You Need to Know Before You Buy or Build an Aircraft Hangar.
Everything You Need to Know Before You Buy or Build an Aircraft Hangar. Table of Contents Introduction Section 1: Airport Environment Section 2: The Pre-Engineered Building Market Section 3: Determining
More informationCHAPTER 22 STEEL SECTION 2204 SECTION 2201 CONNECTIONS GENERAL
CHAPTER 22 STEEL SECTION 2201 GENERAL 2201.1 Scope. The provisions of this chapter govern the quality, design, fabrication and erection of steel used structurally in buildings or structures. Exception:
More informationResidential Agricultural Commercial phone 866-55 BARNS 503.693.0181 PO BOX 1485 Hillsboro, Oregon 97123 OR CCB # 161937 WA CCB # CASCABC942N9 Quality and Pride In Every Job Specializing In Shops Garages
More informationGRAIN STORAGE SYSTEMS
GRAIN STORAGE SYSTEMS FOPRO Grain Systems is a market leader in the design and manufacture of grain storage silo and handling systems. FOPRO has earned an excellent reputation worldwide with superior system
More informationTHE SITUATION WITH STEEL DECKS
THE SITUATION WITH STEEL DECKS Steel roof deck design can affect roof system selection and design by Mark S. Graham 32 www.professionalroofing.net MARCH 2017 teel roof decks commonly are encountered in
More informationAnchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi
STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel
More informationPROVEN SOLUTIONS FOR RE-ROOFING METAL ROOFS ROOF HUGGER
PROVEN SOLUTIONS FOR RE-ROOFING METAL ROOFS ROOF HUGGER Over 80 Million Square Feet Installed Since 1991 Metal-over-Metal Re-roofing What Is Metal-over-Metal Re-roofing? Simply put, Metal-over-Metal Re-roofing
More informationRIB-ROOF System Details. Planning and Building with RIB-ROOF Metal Roofing Systems
System Details Planning and Building with Metal Roofing Systems Metal Roofing Systems Zambelli A Tradition of Innovation The success of Zambelli had its origins in quality, competence and the spirit of
More informationModern Construction and Rehabilitation Techniques
International Journal of Scientific and Research Publications, Volume 4, Issue 8, August 2014 1 Modern Construction and Rehabilitation Techniques Anshu Rajput, Divyanshu Pandey Civil Department, SRM University
More information1.1 RELATED DOCUMENTS
SECTION 133419-PRE-ENGINEERED BUILDING PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationPower Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features
DESIGN CRITERIA FOR STANDARD CONSTRUCTION: These standard design elements of the P.E.I. Power Equipment Center are utilized to meet the following design criteria per ASCE 7-05 as adopted by the IBC (International
More informationINNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT. INSULATED metal PANELS Leading the industry in technology, design flexibility, quality, and value, Nucor Building Systems is one of the largest and most experienced
More informationSOL UTIONS LIVING SOLUTIONS LIVING SOLUTIONS
Buyer s Guide HOMES 1300 985 110 LIVING SUPPORT SOLUTIONS 2 BCDS0868 Contents Just imagine the space you can create 4 More reasons to choose SmartSpace 8 SmartSpace Project Planner 9 Design your SmartSpace
More informationSpecifiers: Click on the icon in the WORD toolbar to reveal detailed instructions
Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated
More informationALL STEEL SHED FRAMES
ALL STEEL SHED FRAMES ABOVE DISPLAY IS AN 8X8 PORTABLE STEEL SHED FRAME WITH FLOOR STRUTS ON 2 FT CENTER SPACING USING QUICK BUILD CONNECTORS - 3 DOOR IS PLACED IN SHORT WALL (configuration of steel may
More informationEasySHED. Easy... in every way 5 STEP ASSEMBLY INNOVATIVE COLOURS RANGE OF OPTIONAL EXTRAS AUSTRALIAN OWNED & MADE
EasySHED Easy... in every way INNOVATIVE 5 STEP ASSEMBLY NEW GARAGE (PG 7) 25 COLOURS RANGE OF OPTIONAL EXTRAS AUSTRALIAN OWNED & MADE EasySHED. For a better outdoor lifestyle solution. Includes StormSHED.
More informationSoftWall Enclosures. Flexible In-plant Enclosure Systems An Excellent Alternative to Rigid Wall Systems
SoftWall Enclosures Flexible In-plant Enclosure Systems An Excellent Alternative to Rigid Wall Systems An Excellent Alternative Soper s Softwall Enclosures are easy to install, dismantle and relocate.
More informationN1 to N3. DuraGalPlus Domestic Construction Manual. Volume 2: DuraGalPlus RHS as lintels (garage beams, window heads)
N1 to N3 Domestic Construction Manual Volume 2: RHS as lintels (garage beams, window heads) Domestic Construction Manual Volume 1: Roof beams - N1 to C3 (N1 to C3 - Rafters) (N1 to N3 - Roof beams, strutting
More informationEziform Ridge Vent Natural Roof Ventilators
Eziform Ridge Vent Natural Roof Ventilators 1 Eziform Ridge Vent Natural Roof Ventilators Eziform Ridge Vents from Eziform Sheet Metal provide an economical, effective and low maintenance method of exhausting
More informationSpandeck. Walkways & Platform Systems QUALITY & STRENGTH YOU CAN TRUST
Walkways & Platform Systems QUALITY & STRENGTH YOU CAN TRUST SPANDECK is a lightweight aluminium walkway bridge, work platform and staging system in one versatile unit. Thanks to its unique reversible
More informationINTRODUCTION. GANG-NAIL Truss System
INTRODUCTION MiTek Australia Ltd revolutionised house construction in Australia when it introduced the use of Gang-Nail multi-tooth connectors for the manufacture of prefabricated timber trusses in the
More informationIndustry Standard Terms & Definitions Of The Steel Deck Institute
Industry Standard Terms & Definitions Of The Steel Deck Institute A specialized set of jargon to describe common terms used by manufacturers and other professionals associated with the usage of Steel Deck
More informationJune GANG-NAIL ROOF TRUSS SYSTEM (incorporating Attic Trusses) Residential Manual
une 2008 GANG-NAIL ROOF TRUSS SYSTEM (incorporating Attic Trusses) Residential Manual GANG-NAIL Roof Truss Systems are available only through GANG-NAIL Fabricators throughout New Zealand Refer to the MiTek
More information2 3 IRON FIST PALLET RACKS THE SHELVING WITH WELD-FREE MONOLI- THIC BEAM We have eliminated a critical point in pallet racks: the welding between the shelf and the beam. We have also added a multi-stiffened
More informationAISI S E1 AISI STANDARD. Errata to North American Specification. for the Design of Cold-Formed. Steel Structural Members.
AISI S100-12-E1 AISI STANDARD Errata to North American Specification for the Design of Cold-Formed Steel Structural Members 2012 Edition Amendment on August 16, 2013 Errata to North American Specification
More informationThe Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.
SECTION 05 31 33 - STEEL FORM DECKING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 - Specification
More informationSoftWall Partitions and Curtains
SoftWall Partitions and Curtains The Ultimate in Cost- Effective Flexibility An Excellent Alternative to Rigid Wall Construction An Excellent Alternative Soper s Softwall Enclosures are easy to install,
More informationCity of Port Orange Adult Activity Center Remodeling SSA Project No Volusia County, Florida October 8, 2009
SECTION 10530 PRE-ENGINEERED ALUMINUM CANOPY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. The extent of aluminum flat style walkway cover is shown on the drawings and as specified herein. 2. Definition:
More information1 1 4" FRAMING SYSTEM
4" FRAMING SYSTEM A000 (4 Gauge)...6-70 A00 (4 Gauge)...7-7 A4000 ( Gauge)...7-74 A000 (4 Gauge)... 7 Channel Nuts and Closure Strips...76-77 Flat Plate Fittings... 77 Ninety Degree Fittings...77-78 Z
More informationE-Series Steel Gantry Crane
SPANCO PRODUCT SPECIFICATIONS 1 E-Series Steel Gantry Crane This guide can be used to prepare a bid specification for the incorporation of an E-Series Gantry Crane into a competitive bid project or application.
More informationMetal Roof Panels
University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 074113 - Metal
More informationN1 to N3. DuraGalPlus Domestic Construction Manual. Volume 3: DuraGalPlus RHS as floor beams (bearers)
N1 to N3 Domestic Construction Manual Volume 3: RHS as floor beams (bearers) DuraGal Domestic Construction Manual Volume 1: Roof beams - N1 to C3 (N1 to C3 - Rafters) (N1 to N3 - Roof beams, strutting
More informationSECTION METAL BUILDING SYSTEMS
SECTION 133419 - METAL BUILDING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationDesign of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar
2.6 Portal frames Portal frames are the most commonly used structural forms for single-storey industrial structures. They are constructed mainly using hot-rolled sections, supporting the roofing and side
More informationRacking System. " Racking Solutions to meet all your storage needs "
Racking System " Racking Solutions to meet all your storage needs " TSSC is the leading manufacturer of racking systems offering a range of customized industrial storage & warehouse solutions to meet all
More informationBIG IDEAS BETTER SOLUTIONS. Metwood Patents and Design Certificates
BIG IDEAS BETTER SOLUTIONS TM A P ublicly Traded Company, Ticker-MTWD Metwood products are extremely adaptable to all types of building systems, and fit right in with wood, log, ICF, SIP, metal, or just
More informationSECTION METAL ROOF PANELS
SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof
More informationPROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS
SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.
More informationOn Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)
TECHNICAL NOTE On Cold-Formed Steel Construction $5.00 Light Gauge Steel Engineers Association Washington, D.C. 20005 Toll Free (866) 465-4732 www.lgsea.com DESIGN OF BY-PASS SLIP CONNECTORS IN COLD-FORMED
More informationBases for Duct Support and Hanging Pipes
RTS systems provide innovative and economical solutions for non-penetrating rooftop support systems. Our environmentally friendly systems dampen vibrations helping to extend roof life while providing stable
More informationRIB-ROOF System Details. Planning and Building with RIB-ROOF Metal Roofing Systems
System Details Planning and Building with Metal Roofing Systems Metal Roofing Systems Zambelli A Tradition of Innovation The success of Zambelli had its origins in quality, competence and the spirit of
More informationRS32 Multi-Section Skylight System under/over seam clip double diverter
INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series
More informationBox Rail. Single Box Rail Bracket
HANGERS & RAILS Box Rail Accordion Door Hangers Max. Door Weight (SWL) 450 lbs Meets ANSI/BHMA A156.14, Grade 1. Rail is carefully formed to give an even tread to hanger wheels. Packaging: Bundled without
More information