Translation authorized by DIBt

Size: px
Start display at page:

Download "Translation authorized by DIBt"

Transcription

1 Date: Reference: 10 Oct III /08 Approval number: Z Validity from: 10 October 2012 to: 10 October 2017 Applicant: INTEWA Ingenieur-Gesellschaft für Energie- und Wassertechnik mbh Jülicher Straße Aachen, Germany Subject of approval: Tunnel stormwater infiltration system with the designation "DRAIN MAX" made of HD-PE The subject of approval named above is herewith granted an allgemeine bauaufsichtliche Zulassung ('national. This allgemeine bauaufsichtliche Zulassung ('national contains twelve pages and three annexes.

2 Page 2 of October 2012 I GENERAL PROVISIONS 1 With the allgemeine bauaufsichtliche Zulassung ('national the fitness for use and the applicability of the subject of approval in accordance with the Landesbauordnungen ('Building Regulations of the Land') have been verified. 2 If in the allgemeine bauaufsichtliche Zulassung ('national requirements are made concerning the special expertise and experience of persons entrusted with the manufacture of construction products and types of construction in accordance with the relevant regulations of the Land following section 17, sub-section 5, of the Musterbauordnung ('Model Building Code'), it shall be noted that this expertise and experience can also be proven by equivalent verifications from other Member States of the European Union. If necessary, this also applies to verifications presented within the framework of the Agreement on the European Economic Area (EEA) or other bilateral agreements. 3 The allgemeine bauaufsichtliche Zulassung ('national does not replace the permits, approvals and certificates prescribed by law for carrying out building projects. 4 The allgemeine bauaufsichtliche Zulassung ('national will be granted without prejudice to the rights of third parties, in particular private property rights. 5 Notwithstanding further regulations in the 'Specific Provisions', manufacturers and distributors of the subject of approval shall make copies of the allgemeine bauaufsichtliche Zulassung ('national available to the user and point out that the allgemeine bauaufsichtliche Zulassung ('national shall be available at the place of use. Upon request copies of the allgemeine bauaufsichtliche Zulassung ('national shall be placed at the disposal of the authorities involved. 6 The allgemeine bauaufsichtliche Zulassung ('national may be reproduced in full only. Partial publication requires the consent of Deutsches Institut für Bautechnik. Texts and drawings of advertising brochures may not be in contradiction to the allgemeine bauaufsichtliche Zulassung ('national. In the event of a discrepancy between the German version of the national technical approval and its English translation, the German version shall prevail. 7 The allgemeine bauaufsichtliche Zulassung ('national is granted until revoked. The provisions of the allgemeine bauaufsichtliche Zulassung ('national technical approval') can subsequently be supplemented and amended, in particular if this is required by new technical findings.

3 Page 3 of October 2012 II SPECIFIC PROVISIONS 1 Subject of approval and field of application The subject of this allgemeine bauaufsichtliche Zulassung ('national is a tunnel system made of polyethylene (HD-PE) with the designation "DRAIN MAX" for stormwater infiltration as part of underground infiltration and storage systems. The allgemeine bauaufsichtliche Zulassung ('national applies to the "DRAIN MAX" tunnel system, consisting of - Start section with the designation "DM-T100S", - Middle tunnel with the designation "DM-T1600M" and - End section with the designation "DM-T100E". The stormwater infiltration systems composed of the above named tunnel system, hereafter referred to as infiltration systems, shall only be used for stormwater infiltration into the substrate, in accordance with the scope of DWA-A Other applications, such as infiltration of untreated runoff from suspected and known contaminated sites as well as from sites such as petrol stations where substances hazardous to water are handled, are not included in the scope of this approval. The tunnel system shall be installed with a soil cover of at least 1.00 m. The surfaces above the infiltration system may not be built up for any purposes except for traffic areas. The traffic loads on the surfaces above infiltration systems may not exceed construction class V in accordance with RStO The allgemeine bauaufsichtliche Zulassung ('national applies only to use of the tunnel system in non-earthquake-prone areas. The infiltration systems consist of no more than one tunnel layer with an overall height of 805 mm. The tunnels may be installed parallel to each other with a minimum distance of 430 mm at base depth, but never on multiple layers. The tunnel systems are classified as non-accessible in accordance with the applicable accident prevention regulations. 2 Provisions for the tunnel system components 2.1 Properties and composition General An infiltration system consists of one or several middle tunnels, whose end faces are closed off by start or end sections. In the system, the tunnels and start or end sections are joined with interlocking connecting ribs that overlap at the ends. All tunnels in an infiltration system are completely covered with a geotextile. Tunnels in which high pressure flushing is scheduled to take place are equipped with a complete underlay of a geocomposite. 1 DWA-A 138 Deutsche Vereinigung für Wasserwirtschaft, Abwasser und Abfall e. V. ('German Association for Water Economy, Wastewater and Waste') (DWA) Worksheet 138: Planning, construction and operation of facilities for the percolation of precipitation water, issue: RStO 01 Forschungsgesellschaft für Straßen- und Verkehrswesen (FGSV): Guidelines for the standardisation of the superstructure in traffic areas; FGSV Verlag; issue: 2001

4 Page 4 of October Material and material characteristics The tunnel system components are made of high density polypropylene in accordance with the formula specifications which are stored with Deutsches Institut für Bautechnik (DIBt), which shall at least exhibit the following properties prior to processing: - Density in accordance with DIN EN ISO g/cm³ ± g/cm³ - Melt mass-flow rate (MFR 230 C/2.16 kg) in accordance with DIN EN ISO g/10 min 0.5 g/10 min After processing, the material shall at least possess the following characteristics: - Density in accordance with DIN EN ISO g/cm³ ± g/cm³ - Melt mass-flow rate (MFR 230 C/2.16 kg) in accordance with DIN EN ISO g/10 min 0.5 g/10 min - Thermal stability in accordance with DIN EN min - Charpy impact strength (test method 'ea') in accordance with DIN EN ISO at 23 C 20 kj/m² - Longitudinal reversion in accordance with DIN EN ISO < 1.0 % - Filler content in accordance with DIN EN ISO % - Tensile properties in accordance with DIN EN ISO Modulus of elasticity under tension E T 980 MPa Tensile strength σ M 21.5 MPa - Bending properties in accordance with DIN EN ISO Bending strength σ B (short-term) 26.9 MPa Bending strength σ B (long-term) 17.6 MPa Flexural creep modulus E t (long-term) 150 MPa Dimensions and weight Form, dimensions and tolerances of the tunnel system meet the specifications given in Annexes 1 to 3. The weight of the middle tunnel is at least 30.5 kg, the start section at least 5.2 kg and the end section at least 5.3 kg. 3 DIN EN ISO Plastics Methods for determining the density of non-cellular plastics Part 1: Immersion method, liquid pyknometer method and titration method (ISO :2004); German version EN ISO :2004; issue: DIN EN ISO 1133 Plastics Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics (ISO 1133:2005); German version EN ISO 1133:2005; issue: DIN EN ISO Plastics Determination of Charpy impact properties Part 1: Non-instrumented impact test (ISO 179-1:2010); German version EN ISO 179-1:2010; issue: DIN EN ISO 2505 Thermoplastics pipes Longitudinal reversion Test method and parameters (ISO 2505:2005); German version EN ISO 2505:2005; issue: DIN EN ISO 1172 Textile-glass-reinforced plastics - Prepregs, moulding compounds and laminates - Determination of the textile-glass and mineral-filler content; calcination methods (ISO 1172:1996); German version EN ISO 1172:1998; issue: DIN EN ISO Plastics Determination of tensile properties Part 2: Test conditions for moulding and extrusion plastics (ISO 527-2:1993 including Cor.1:1994); German version EN ISO 527-2:1996; issue: DIN EN ISO Plastics - Determination of creep behaviour Part 2: Flexural creep by three-point loading (ISO 899-2:2003); German version EN ISO 899-2:2003; issue:

5 Page 5 of October Appearance of the tunnel system In a visual inspection without optical aids the tunnel system components exhibit a smooth surface free of scratches, bubbles, impurities, sunken areas and other irregularities (defects) as can be expected for the manufacturing process. All surfaces are free from burrs Colour The tunnel system components are uniformly black throughout Strength properties When a vertical crown compressive force of at least 18.4 kn/m is applied distributed across the crown in accordance with the regulations in section clause 10, the infiltration tunnels exhibit a maximum deformation of 78 mm at the crown Geotextile The entire base area of the tunnels in which high pressure flushing is scheduled to take place shall be lined with a geocomposite that is resistant to high pressure flushing. All tunnels are completely covered with a geotextile. Only the geotextile with the designation "INTEWA Geotextil GT 300" and the geocomposite with the designation "INTEWA Geoverbundstoff GVS 500" with the respective technical specifications stored with DIBt shall be used. 2.2 Manufacture, packaging, transport, storage and marking Manufacture The tunnel system components shall be manufactured using the vacuum forming process in consideration of the provisions given in section and shall possess the characteristics described in section 2.1 in accordance with the information given in Annexes 1 to 3. During manufacture, at least the following production parameters shall be calibrated and continuously recorded each time the machine is started: - Vacuum forming temperature - Vacuum - Sheet weight Only the material stored with DIBt and with trade names, manufacturers and characteristics corresponding to the specifications given in section shall be used for the manufacturing process. Use of process scrap of the same composition from the applicant's factories is permissible Packaging, transport and storage The tunnel system components shall be secured for storage and transport such that no impermissible deformation and no damage occurs. The corresponding storage and transport instructions of the applicant and the relevant accident prevention regulations shall be observed Marking The tunnel system components shall be marked by the applicant with the mark of conformity ('Ü mark') in accordance with the conformity marking regulations of the Laender including approval no. Z The mark may only be applied if the requirements given in section 2.3 are met. The tunnel system components shall also each be marked at least once in a clearly visible and durable manner with the following information: - Type designation - Material HDPE - Production facility - Date of fabrication

6 Page 6 of October Attestation of conformity General The attestation of conformity of the tunnel system components with the provisions of this allgemeine bauaufsichtliche Zulassung ('national shall be issued for every production facility in the form of a certificate of conformity based on factory production control and regular external surveillance, including initial type-testing of the tunnel system components in accordance with the following provisions. To issue the certificate of conformity and for external surveillance, including the associated product testing to be carried out in the process, the applicant shall use an appropriately recognised certification body and an appropriately recognised inspection body. The declaration that a certificate of conformity has been granted shall be submitted by the applicant through marking of the construction products with the mark of conformity ('Ü mark') stating the intended use. The certification body shall send a copy of the certificate of conformity issued by the same to Deutsches Institut für Bautechnik. A copy of the initial type-testing evaluation report shall also be sent to Deutsches Institut für Bautechnik Factory production control A factory production control system shall be set up and implemented in each production facility. Factory production control is understood to be continuous surveillance of production by the applicant to ensure that the construction products manufactured satisfy the provisions of this allgemeine bauaufsichtliche Zulassung ('national. The factory production control shall at least include the measures listed below: - Description and verification of the starting material and the constituents: The characteristics of the material used and checking of these characteristics shall comply with the specifications given in section For each delivery the manufacturer of the tunnel system components shall obtain confirmation of conformity of the material used with the specifications given in section in the form of an acceptance test certificate 3.1 in accordance with DIN EN from the raw materials supplier. Within the scope of the factory production control, a spot check shall be carried out on each delivery to determine whether the supplied material complies with the requirements for density and the melt mass-flow rate. - Checks and tests to be carried out during manufacture: The specifications given in section shall be complied with. - Verifications and tests to be carried out on the finished construction product: At least the requirements given in the following sections shall be checked: 1. Compliance with the density of the processed material as specified in section shall be checked every time the raw material is changed and once a week in accordance with DIN EN ISO The value specified in section for the melt mass-flow rate of the processed polypropylene shall be checked in accordance with DIN EN ISO to ensure compliance with the limit values once a week as well as every time the raw material is changed. 3. Compliance with the values for dimensional change after warm storage specified in section shall be checked every time the raw material is changed and once a month on a spot check basis in accordance with DIN EN ISO Compliance with the tensile strength σ M and the modulus of elasticity under tension E T specified in section shall be checked every time the raw material is changed and 10 DIN EN Metallic products Types of inspection documents; German version EN 10204:2004; issue:

7 Page 7 of October 2012 once a month on a spot check basis in accordance with DIN EN ISO Compliance with the short-term bending strength σ M specified in section shall be checked every time the raw material is changed and once a month on a spot check basis in accordance with DIN EN ISO Compliance with the Charpy impact strength specified in section shall be checked every time the raw material is changed and once a month on a spot check basis in accordance with DIN EN ISO 179-1/1eA Agreement with the values specified in section regarding the dimensions of the tunnel system components shall be checked upon start of production and thereafter once every week, every time the raw materials are changed and whenever changes are made to the system parameters. All dimensions affecting the function shall be checked; these include: - Lengths, widths, and height of the components - Rib geometry - Wall thicknesses and - Weight. 8. Agreement with the specifications in section regarding the condition of the tunnel system components shall be checked continuously upon start of production and thereafter once every shift. 9. Agreement with the specifications in section regarding the colouring of the tunnel system components shall be checked continuously upon start of production and thereafter once every shift. 10. For the verification of the strength properties specified in section 2.1.6, the infiltration tunnels shall be loaded with an increasing force that is distributed longitudinally along the crown, after a conditioning time of at least 24 h at 22 C to 23 C room temperature and with lateral restraint by the supports. The applied force and the vertical deformation at the crown shall be recorded continuously over the entire course of the test. The force is applied with a test speed of 0.5 kn/(ms) and shall be continuously increased until the maximum testing load of 18.4 kn/m is reached. The infiltration tunnel being tested is deemed to have failed if there is - A drop in force before the maximum test load has been reached, - A loss of stability before the maximum test load has been reached, or - A vertical deformation in the crown area > 78 mm before the maximum test load has been reached. The strength properties of the infiltration tunnels shall be checked at least upon start of production, after each change of raw materials and after each change in system parameters, or at least once a day. 11. Compliance with the manufacture and marking specifications given in sections and shall be checked continuously during production. The results of factory production control shall be recorded and evaluated. The records shall at least include the following information: - Designation of the construction product or the starting product and the constituents - Type of inspection or test - Date of manufacture and testing of the construction product or the starting material - Results of the inspections and tests as well as (if applicable) comparison to requirements - Signature of the person responsible for factory production control The records shall be kept for at least five years and submitted to the inspection body used

8 Page 8 of October 2012 for external surveillance. They shall be presented to Deutsches Institut für Bautechnik and the competent supreme building supervisory authority upon request. If the test result is unsatisfactory, the applicant shall immediately take the necessary measures to resolve the defect. Construction products which do not meet the requirements shall be handled in such a manner that they cannot be mixed up with compliant products. After the deficiencies have been remedied, the relevant test shall be repeated immediately where this is technically possible and necessary to demonstrate that the deficiencies have been remedied External surveillance The factory production control system at each production facility shall be inspected regularly, i.e. at least twice a year, by means of external surveillance. Initial type-testing of the tunnel system components shall also be carried out within the scope of external surveillance. Spot checks shall be carried out to check for compliance with the requirements given in section 2.3.2, in particular the requirements for strength properties of the tunnel system components corresponding to the specifications given in section Sampling and testing are always the responsibility of the recognised inspection body. The results of certification and external surveillance shall be kept for at least five years. They shall be presented by the certification or inspection body to Deutsches Institut für Bautechnik and the competent supreme building supervisory authority upon request. 3 Provisions for the dimensioning 3.1 Infiltration performance Unless otherwise specified, the dimensioning principles and conditions of worksheet DWA-A and of the advisory leaflet ATV-DVWK-M of Deutsche Vereinigung für Wasserwirtschaft, Abwasser und Abfall e. V. ('German Association for Water Economy, Wastewater and Waste') shall apply for the dimensioning of the infiltration systems. For the purposes of ensuring the performance of the infiltration system, the corresponding hydraulic verifications of the infiltration capacity of the ground as well as the local groundwater conditions, for instance in conjunction with a geotechnical report, shall be obtained as a basis for system dimensioning. 3.2 Stability The stability of each individual infiltration system shall be verified through static calculations or through a verified type-based statistic analysis for the ultimate limit state (ULS) and for the serviceability limit state (SLS) for maximum allowable deflections of h zul 6 % with σ E,d σ R,d (1) where σ E,d is the design value for the loads/forces acting on the component and σ R,d is the design value for the structural resistance of the component. The static calculations shall be checked by an official testing authority for construction analysis or an officially recognised test engineer to ensure stability. Verification is provided when the load-bearing capacity in accordance with Gl. (1) is verified. Type-based static analyses can be created for standard installations; these shall be checked by an official testing authority for construction analysis. 11 ATV-DVWK-M 153 Deutsche Vereinigung für Wasserwirtschaft, Abwasser und Abfall e. V. ('German Association for Water Economy, Wastewater and Waste') (DWA) - Advisory leaflet 153: Recommended actions for dealing with stormwater; issue:

9 Page 9 of October 2012 The stresses (actions) σ E,d are determined based on a failure model with side bedding. The actions shall be determined for: - constant loads σ G,k in accordance with DIN , DIN , DIN and if applicable DIN EN The partial safety factor γ G in accordance with DIN shall be applied, but shall at least correspond to the value given in table 2. - fluctuating loads σ Q,k in accordance with DIN technical report with a partial safety factor γ Q which, however, shall at least be as high as the value given in table 2. In the determination of the design value for the resistance of the infiltration system components σ R,d, the infiltration system is assumed to have a characteristic maximum shortterm compressive strength σ R,k for the ultimate limit state or for the serviceability limit state in accordance with table 1 in consideration of a partial safety factor γ M for the structural resistance which is at least as high as the value given in table 2. Table 1: Characteristic maximum short-term compressive strength σ R,k for the ultimate limit state and the serviceability limit state σ R,k Serviceability limit state max. deformation 4.0% max. deformation 6.0% 140 kn/m² 170 kn/m² Ultimate limit state 220 kn/m² Table 2: Applicable partial safety factors Partial safety factor for ULS SLS Constant loads γ G Fluctuating loads γ Q Structural resistance γ M For the lowering of the resistance of the tunnel system components at least the reduction factors given in table 3 shall be applied. Table 3: Reduction factors for structural resistance Compressive creep A a) / 1.6 b) Effect of media A Effect of temperature A Inhomogeneities (including effect of joints and connections) A DIN Actions on structures - Densities and weights of building materials, structural elements and stored materials; issue: DIN Actions on structures Soil properties; issue: DIN Actions on structures Self-weight and imposed load in building; issue: DIN Actions on structures - Snow loads and ice loads; issue: DIN 1054 Subsoil Verification of the safety of earthworks and foundations Supplementary rules to DIN EN ; issue: DIN technical report 101 Actions on bridges; issue:

10 Page 10 of October 2012 Effect of dynamic loads A a) at serviceability limit state b) at ultimate limit state Verification for the limit states is then carried out using: σ E,d = Σ σ G,k x γ G + Σ σ Q,k x γ Q σ R,k / (γ M x A 1 x A 2 x A 3 x A 4 x A 5 ) = σ R,d (2) 4 Provisions for execution For assembly of the individual tunnel system components into an infiltration system, the provisions for dimensioning in sections 3.1 and 3.2 shall apply. Unless otherwise specified, the following technical rules shall generally be observed: - DWA-A ATV-DVWK-M DIN The infiltration system may only be built in connection with pipes, moulded components and access chambers which comply with the generally recognised rules of engineering or which are marked with the mark of conformity ('Ü mark'). The applicant shall supply an installation manual with each delivery. Installation shall be carried out in accordance with the installation instructions and in consideration of the following provisions: The system may only be built by individuals possessing the necessary specialised knowledge. For the excavation work the principles of DIN shall apply. A level, flat and strong subgrade made from non-cohesive, compressible ground material with a minimum load bearing capacity of E v2 = 45 MN/m² shall be created to facilitate laying. When the individual tunnel system components are being installed it shall be ensured that they have the correct vertical and horizontal alignment. The minimum distance of the tunnels shall be at least 430 mm at base depth. Damaged middle tunnels, start or end sections shall not be installed. Every individual tunnel in an infiltration system shall be equipped with a separate ventilation device at crown height. The dimensioning of the ventilation device shall always be determined depending on the expected feed volume flow. The infiltration system shall be completely wrapped with a geotextile (cover) or geocomposite (underlay) with each wrap having an overlap of at least 25 cm. The overlaps shall be designed such that no backfill material can penetrate into the infiltration system. For ensuring the stability of the overall infiltration system, side backfilling shall always be carried out before the infiltration system is covered. Non-cohesive, compactable material shall be used for side backfilling and final covering, which shall always be installed in layers no thicker than 20 cm with a minimum compaction of D pr 97%, with the required degree of compaction depending on the planned later surface use and to be determined for each individual case. The compaction shall be carried out with a suitable tool. During installation of the infiltration system and implementation of side backfilling and covering of the excavation, the infiltration system shall not be driven over. Installation shall always be carried out using an end tipping method, for example with wheel loaders or excavators. 18 DIN 4124 Excavations and trenches Slopes, planking and strutting breadths of working spaces; issue:

11 Page 11 of October 2012 The executing company shall provide a written declaration of compliance with the provisions for execution of this allgemeine bauaufsichtliche Zulassung ('national for each infiltration system built. The relevant accident prevention regulations shall be observed during execution. 5 Marking of the infiltration system The infiltration system shall be marked above ground by a sign which shall be marked in a permanent and legible manner with the following information: - Size of infiltration system - Depth of infiltration system - Product name - Year of installation In addition, the tunnels in which high pressure flushing is scheduled to take place shall be marked accordingly. 6 Provisions for use and maintenance During use and maintenance of the infiltration system composed of tunnel system components, the relevant accident prevention regulations shall be observed. During the validity period of this approval, the applicant shall submit at least three reports on the inspections carried out on the infiltration systems to Deutsches Institut für Bautechnik. Rudolf Kersten Head of Section Beglaubigt

12 Allgemeine bauaufsichtliche Zulassung ('national of 10 October 2012 Tunnel stormwater infiltration system with the designation "DRAIN MAX" made of HD-PE Annex 1 DRAIN MAX Tunnel DM-T 100 S, DM-T 100 E, DM-T 1600 M

13 Allgemeine bauaufsichtliche Zulassung ('national of 10 October 2012 Tunnel stormwater infiltration system with the designation "DRAIN MAX" made of HD-PE Annex 2 DRAIN MAX Tunnel DM-T 100 S, DM-T 100 E, DM-T 1600 M

14 Allgemeine bauaufsichtliche Zulassung ('national of 10 October 2012 Tunnel stormwater infiltration system with the designation "DRAIN MAX" made of HD-PE DRAIN MAX Tunnel DM-T 100 S, DM-T 100 E, DM-T 1600 M Annex 3

Translation authorised by DIBt. to: 1 December January 2017 I /16

Translation authorised by DIBt. to: 1 December January 2017 I /16 Date: Reference: 24 January 2017 I 29-1.21.1-23/16 Approval number: Z-21.1-1711 Validity from: 1 December 2016 to: 1 December 2021 Applicant: fischerwerke GmbH & Co. KG Klaus-Fischer-Straße 1 72178 Waldachtal

More information

National technical approval Coupler

National technical approval Coupler National technical approval Coupler Z-1.5-100 12.02.2015 english Mechanical connection of B500B reinforcing steel bars with screw couplers Nominal diameter: 12 to 32 mm Tested by: DIBt, Berlin Max Frank

More information

Translation authorized by DIBt

Translation authorized by DIBt Date: Reference: 11.01.2012 I 38-1.70.3-1/12 Approval number: Z-70.3-175 Validity from: 11 January 2012 to: 11 January 2017 Applicant: seele sedak GmbH & Co. KG Einsteinring 1 86368 Gersthofen, Germany

More information

Translation from German (14 pages in all) Translation of the German original version not revised by the Deutsches Institut für Bautechnik

Translation from German (14 pages in all) Translation of the German original version not revised by the Deutsches Institut für Bautechnik Translation from German (14 pages in all) Translation of the German original version not revised by the Deutsches Institut für Bautechnik National Deutsches Institut für Bautechnik 1 Technical ANSTALT

More information

HALFEN HLB LOOP BOX Z-HLB-M50 13-E CONCRETE

HALFEN HLB LOOP BOX Z-HLB-M50 13-E CONCRETE HALFEN HLB LOOP BOX Z-HLB-M50 13-E CONCRETE Translation of the General Certificate of Approval Approval Office: German Institute for Construction Engineering (Deutsches Institut für Bautechnik DIBt) Kolonnenstrasse

More information

Sewage and rainwater. Experience the leading GIGAPIPE System! GIGAPIPE System. PP-System SN8 DN / ID 150 mm DN / ID 1000 mm

Sewage and rainwater. Experience the leading GIGAPIPE System! GIGAPIPE System. PP-System SN8 DN / ID 150 mm DN / ID 1000 mm Sewage and rainwater Experience the leading GIGAPIPE System! GIGAPIPE System PP-System SN8 DN / ID 150 mm DN / ID 1000 mm DROSSBACH corrugated GIGAPIPE Systems Lighter, more solid and truly higher quality!

More information

REPORT STATUS: DATE: Report n :

REPORT STATUS: DATE: Report n : REPORT: Expanded clay LWA in CEA Lightweight fill and thermal insulation products for civil engineering applications. Installation and structural quality control on site. STATUS: Technical report DATE:

More information

European Technical Approval No. ETA-12/0056

European Technical Approval No. ETA-12/0056 SINTEF Building and Infrastructure P.O.Box 124 Blindern N-0314 Oslo Tel. 47 22 96 55 55 Fax 47 22 69 94 38 Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December

More information

D E U T S C H E S I N S T I T U T F Ü R B A U T E C H N I K

D E U T S C H E S I N S T I T U T F Ü R B A U T E C H N I K D E U T S C H E S I N S T I T U T F Ü R B A U T E C H N I K Corporation under Public Law 10829 Berlin, 17 July 2002 Kolonnenstraße 30 L Telefon: (0 30) 7 87 30-356 Telefax: (0 30) 7 87 30-320 GeschZ.:

More information

Heating elements shall not be used for FRP tank-containers including tank swap bodies.

Heating elements shall not be used for FRP tank-containers including tank swap bodies. Chapter 6.9 6.9.1 General Requirements for the design, construction, equipment, type approval, testing and marking of fibre-reinforced plastics (FRP) tank-containers including tank swap bodies NOTE: For

More information

ISO Steels for the reinforcement of concrete Reinforcement couplers for mechanical splices of bars Requirements

ISO Steels for the reinforcement of concrete Reinforcement couplers for mechanical splices of bars Requirements INTERNATIONAL STANDARD ISO 15835-1 First edition 2009-04-01 Steels for the reinforcement of concrete Reinforcement couplers for mechanical splices of bars Part 1: Requirements Aciers pour l'armature du

More information

Construction. Tricosal Waterstops - Tricomer. Waterstops for joint sealing in watertight concrete construction according to DIN and DIN

Construction. Tricosal Waterstops - Tricomer. Waterstops for joint sealing in watertight concrete construction according to DIN and DIN Construction Product Data Sheet Edition 19 April 2013 Tricosal Waterstops - Tricomer Waterstops for joint sealing in watertight concrete construction according to DIN 18541 and DIN 18541-2 Product Description

More information

SECTION FOUNDATION DRAINAGE

SECTION FOUNDATION DRAINAGE SECTION 33 41 13 SPEC WRITER NOTES: Use this section only for NCA projects. Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

HT 20plus. Formwork timber beams. Facts on formwork timber beams: Contents. Product standard. Wood types. Beam height. Weight.

HT 20plus. Formwork timber beams. Facts on formwork timber beams: Contents. Product standard. Wood types. Beam height. Weight. Formwork timber beams Facts on formwork timber beams: Contents Wood types Spruce / Fir Beam height 20 cm Lengths Lengths up to 10 m Product standard Technical approval certificate Z-9.1-146 Weight 4,6

More information

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating

More information

SPECIFICATION FOR REINFORCED SOIL WALL

SPECIFICATION FOR REINFORCED SOIL WALL SPECIFICATION FOR REINFORCED SOIL WALL 1.0 EXTENT OF WORK The work shall consist of Reinforced Soil walls built in accordance with this specification and in conformity with the lines, levels and details

More information

EXPANDED POLYSTYRENE (EPS GEOFOAM) EMBANKMENT DIVISION 31 EARTHWORK

EXPANDED POLYSTYRENE (EPS GEOFOAM) EMBANKMENT DIVISION 31 EARTHWORK (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying AMVIC GEOFOAM products and execution. The specifier needs to edit the guide specifications to

More information

Large plastic pipe technology. Large diameter pressure pipe. up to DN/ID 5000 mm

Large plastic pipe technology. Large diameter pressure pipe. up to DN/ID 5000 mm Large plastic pipe technology Large diameter pressure pipe up to DN/ID 5000 mm Powerful and designed according to YOUR specifications Large diameter pressure pipes No sagging and less wallthickness saves

More information

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics HEKAPLAST PE-HD twin wall cable ducts and cable protection pipes for underground installation HEGLER HEKAPLAST III/ HEKAPLAST: Twin wall cable ducts or cable protection pipes to DIN 696, manufactured from

More information

European Technical Approval ETA-07/0025

European Technical Approval ETA-07/0025 European Technical Approval ETA-07/0025 - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and

More information

GRAF STORMWATER MANAGEMENT SYSTEMS GRAF INFILTRATION TUNNEL SYSTEM

GRAF STORMWATER MANAGEMENT SYSTEMS GRAF INFILTRATION TUNNEL SYSTEM GRAF UK Ltd Target House Thorpe Way Industrial Estate Banbury Oxfordshire OX16 4SP Tel: 01608 661500 e-mail: info@grafuk.co.uk website: www.grafuk.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Deutsches Institut für Bautechnik

Deutsches Institut für Bautechnik National Technical Approval Deutsches Institut für Bautechnik Public-law institution Approval body for construction products and construction types Technical testing laboratory Member of the European Organisation

More information

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS SECTION 02620 PART 1 GENERAL 1.1 SCOPE OF WORK A. Furnish all labor, materials, equipment, and incidentals required to install High Density Polyethylene (HDPE) pressure pipe, fittings, and appurtenances

More information

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT SECTION 32 14 13 19 PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT SECTION 32 14 13 19 PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Permeable Articulating

More information

General Construction Supervisory Authority Approval

General Construction Supervisory Authority Approval General Construction Supervisory Authority Approval (Translation of the German original text which has not been checked by the DIBt.) Approval no.: Z-21.8-2018 Period of validity: April 1, 2014 until:

More information

SERIES 1100 KERBS, FOOTWAYS AND PAVED AREAS

SERIES 1100 KERBS, FOOTWAYS AND PAVED AREAS MANUAL OF CONTRACT DOCUMENTS FOR HIGHWAY WORKS VOLUME 1 THE SPECIFICATION FOR HIGHWAY WORKS SERIES 1100 KERBS, FOOTWAYS AND PAVED AREAS Contents Clause Title Page 1100 (02/17) General 2 #1101 Precast Concrete

More information

TECHNYL A 218 V35 BLACK 21N

TECHNYL A 218 V35 BLACK 21N TECHNICAL DATA SHEET TECHNYL A 218 V35 Black 21N is a polyamide 66, reinforced with 35% of glass fibre, heat stabilized, for injection moulding. This grade offers an excellent combination between thermal

More information

Proposed Structure and Construction Method for Improved Interlocking Concrete Block Pavement Used in Residential Parking Spaces

Proposed Structure and Construction Method for Improved Interlocking Concrete Block Pavement Used in Residential Parking Spaces Proposed Structure and Construction Method for Improved Interlocking Concrete Block Pavement Used in Residential Parking Spaces Akihiko Karasawa, 1 Masahiko Nakamura, 1 Yoshio Yanagisawa 1 1 S-BIC Company

More information

Specification texts FRIAFIT sewage system

Specification texts FRIAFIT sewage system Specification texts FRIAFIT sewage system Norm Conformity The FRIAFIT sewage system of PE 100 complies with EN 12666 and hence is deemed a regulated construction product. It therefore does not need general

More information

Technical Data. Application Recommendations Dimensioning Aids.

Technical Data. Application Recommendations Dimensioning Aids. Technical Data Application Recommendations Dimensioning Aids www.styrodur.com Application Recommendations Styrodur 1. Application Recommendations Styrodur Application type according to DIN 4108-10 or technical

More information

SPECIFICATION for ISCO HDPE DUAL CONTAINMENT PIPE

SPECIFICATION for ISCO HDPE DUAL CONTAINMENT PIPE SPECIFICATION for ISCO HDPE DUAL CONTAINMENT PIPE SECTION 15000 MECHANICAL 1. GENERAL 1.1 This specification shall govern the materials and installation of polyethylene dual contained system of pipe, structures

More information

European Technical Assessment. ETA-12/0398 of 29/12/2017. General Part. Instytut Techniki Budowlanej. Technical Assessment Body issuing the

European Technical Assessment. ETA-12/0398 of 29/12/2017. General Part. Instytut Techniki Budowlanej. Technical Assessment Body issuing the European Technical Assessment General Part of 29/12/2017 (English language translation the original version is in Polish language) Body issuing the European Trade name of the construction product Product

More information

A PRODUCT FROM KANTAFLEX (INDIA) PVT LIMITED

A PRODUCT FROM KANTAFLEX (INDIA) PVT LIMITED ELASTOMERIC BRIDGE BEARING TO LATEST IRC: 83-015 (PART - II) Kanta System of Elastomeric bridge bearing is made out of Poly chloroprene rubber having low crystallization rates and adequate shelf life,

More information

THE ADVANTAGES HDPE MANHOLES

THE ADVANTAGES HDPE MANHOLES NIC HDPE manholes are custom fabricated for many varied applications including municipal and industrial manholes, sewer and storm water manholes, leach ate collection, sewer lift stations, siphon structures,

More information

INTERNATIONAL STANDARD ISO 4427-2 First edition 2007-08-01 Plastics piping systems Polyethylene (PE) pipes and fittings for water supply Part 2: Pipes Systèmes de canalisations en plastique Tubes et raccords

More information

2. TEST RECORDS: All records of tests and analysis shall be kept in suitable forms approved by the Bureau.

2. TEST RECORDS: All records of tests and analysis shall be kept in suitable forms approved by the Bureau. SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF CARBON STEEL BILLETS, BLOOMS, SLABS AND BARS FOR FORGINGS ACCORDING TO IS:1875-1992 (Fifth Revision) 1. LABORATORY: A laboratory shall be maintained

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 7391-2 Third edition 2006-03-01 Plastics Polycarbonate (PC) moulding and extrusion materials Part 2: Preparation of test specimens and determination of properties Plastiques

More information

European Technical Approval ETA-02/0030

European Technical Approval ETA-02/0030 European Technical Approval ETA-02/0030 - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and

More information

1E5 Advanced design of glass structures. Martina Eliášová

1E5 Advanced design of glass structures. Martina Eliášová 1E5 Advanced design of glass structures Martina Eliášová List of lessons 1) History, chemical, production 2) Glass as a material for load bearing structures 3) Design of laminated plates 4) Design of glass

More information

IN THE FIELD PIPE INSTALLATION INSTRUCTIONS

IN THE FIELD PIPE INSTALLATION INSTRUCTIONS The Company With Connections MT THE NEXT LEVEL OF FLEXIBLE CONNECTORS A-LOK PREMIUM ASTM C-923 APPLICATION A LOK PREMIUM Designed to produce a guaranteed watertight seal between pipe and concrete, the

More information

h Installation Manual

h Installation Manual h Installation Manual 1 General Information The installation of HOBAS GRP Pipes is subject to applicable standards and guidelines such as EN 1610 and ISO/ TS 10465-1. Correct installation always requires

More information

Sarnavap 1000E is an unsupported vapour control layer based on PE-LD (Low Density Polyethylen).

Sarnavap 1000E is an unsupported vapour control layer based on PE-LD (Low Density Polyethylen). Roofing Roofing Product Data Sheet Edition 06.2013 Version no. DE 01 English Vapour control layer Product Description Uses Characteristics / Advantages Tests is an unsupported vapour control layer based

More information

Structural Design of Pergola with Airfoil Louvers

Structural Design of Pergola with Airfoil Louvers International Journal of Advanced Structures and Geotechnical Engineering ISSN 2319-5347, Vol. 04, No. 03, July 2015 Structural Design of Pergola with Airfoil Louvers MUHAMMAD TAYYAB NAQASH Aluminium TechnologyAauxiliary

More information

Evaluation of Profile Wall Polyvinyl Chloride Drainage Pipe Manufacturers

Evaluation of Profile Wall Polyvinyl Chloride Drainage Pipe Manufacturers NTPEP Committee Work Plan for Evaluation of Profile Wall Polyvinyl Chloride Drainage Pipe Manufacturers NTPEP Designation: PVC-17-01 National Transportation Product Evaluation Program 444 North Capitol

More information

DIBt APPROVAL NEWSLETTER INSIDE: ABOUT DIBT PART NUMBERS HUCK BOBTAIL DIBT APPROVAL COATING MECHANICAL VALUES NEXT STEP

DIBt APPROVAL NEWSLETTER INSIDE: ABOUT DIBT PART NUMBERS HUCK BOBTAIL DIBT APPROVAL COATING MECHANICAL VALUES NEXT STEP DIBt APPROVAL NEWSLETTER INSIDE: ABOUT DIBT HUCK BOBTAIL DIBT APPROVAL MECHANICAL VALUES PART NUMBERS COATING NEXT STEP It s Official: Alcoa Fastening Systems Huck BobTail Offers Maintenance Free Joints

More information

Technical Data. Recommended Applications Assistance Data for Dimensioning. Styrodur C Europe s green insulation

Technical Data. Recommended Applications Assistance Data for Dimensioning. Styrodur C Europe s green insulation Technical Data Recommended Applications Assistance Data for Dimensioning Styrodur C Europe s green insulation 1. Recommended Applications Styrodur C Styrodur C 2500 C 2800 C 3035 CS 3035 CN 4000 CS 5000

More information

Scientific Seminar Design of Steel and Timber Structures SPbU, May 21, 2015

Scientific Seminar Design of Steel and Timber Structures SPbU, May 21, 2015 Riga Technical University Institute of Structural Engineering and Reconstruction Scientific Seminar The research leading to these results has received the funding from Latvia state research programme under

More information

SOLAR KEYMARK SPECIFIC SCHEME RULES ANNEX E: FACTORY PRODUCTION CONTROL INFORMATIVE BASED ON ISO 9001 STANDARD COVERING THE PRODUCTION LINE

SOLAR KEYMARK SPECIFIC SCHEME RULES ANNEX E: FACTORY PRODUCTION CONTROL INFORMATIVE BASED ON ISO 9001 STANDARD COVERING THE PRODUCTION LINE SOLAR KEYMARK SPECIFIC SCHEME RULES ANNEX E: FACTORY PRODUCTION CONTROL INFORMATIVE BASED ON ISO 9001 STANDARD COVERING THE PRODUCTION LINE 1. General This annex specifies the requirements for the Factory

More information

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CONCRETE SEGMENTAL RETAINING WALL SYSTEM CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Classic 8, Classic 6 and Legend unit segmental

More information

Designation: D 2412 02 (Reapproved 2008) An American National Standard Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading 1 This standard

More information

NOTES ON CORRUGATED PLASTIC PIPE SUBSOIL DRAIN CONSTRUCTION SPECIFICATION

NOTES ON CORRUGATED PLASTIC PIPE SUBSOIL DRAIN CONSTRUCTION SPECIFICATION TNZ F/5 Notes: 2000 NOTES ON CORRUGATED PLASTIC PIPE SUBSOIL DRAIN CONSTRUCTION SPECIFICATION These notes are for guidance and must not be included in the Contract Documents In general subdivision numbers

More information

Certification of anti-seismic devices according to the European Standard EN 15129:2009: Tasks for manufacturers and notified bodies

Certification of anti-seismic devices according to the European Standard EN 15129:2009: Tasks for manufacturers and notified bodies Certification of anti-seismic devices according to the European Standard EN 15129:2009: Tasks for manufacturers and notified bodies D. Ferroni, G. Vazzana, D. Cuminetti, V. Quaglini, P. Dubini & C. Poggi

More information

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION SPECIFICATION FOR PIPE CULVERT CONSTRUCTION 1. SCOPE Pipe culverts shall be constructed in accordance with this specification and in conformity with the lines, levels and cross-sections shown on the drawings.

More information

CORRUGATED HDPE PIPES FOR SEWER AND STORMWATER

CORRUGATED HDPE PIPES FOR SEWER AND STORMWATER 50 corrugated pipes CORRUGATED HDPE PIPES FOR SEWER AND STORMWATER TECHNICAL SPECIFICATIONS SANS 21138-3 ISO 9001/2008 The pipe is black outside and blue on the inside Supplied in lengths of 6 meters.

More information

EN DK NA:2007

EN DK NA:2007 EN 1995-1-1 DK NA:2007 National Annex to Eurocode 5: Design of timber structures - Part 1-1: General - Common rules and rules for buildings Foreword In connection with the incorporation of Eurocodes into

More information

Evaluation of HDPE (High Density. Drainage Pipe Manufacturers. Polyethylene) Thermoplastic. NTPEP Committee Work Plan for

Evaluation of HDPE (High Density. Drainage Pipe Manufacturers. Polyethylene) Thermoplastic. NTPEP Committee Work Plan for NTPEP Committee Work Plan for Evaluation of HDPE (High Density Polyethylene) Thermoplastic Drainage Pipe Manufacturers NTPEP Designation: [HDPE-01-16] National Transportation Product Evaluation Program

More information

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE) SECTION 02623 HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE) PART 1 - GENERAL 1.1 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required and install high density

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 21138-2 First edition 2007-10-15 Plastics piping systems for non-pressure underground drainage and sewerage Structured-wall piping systems of unplasticized poly(vinyl chloride)

More information

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL 1. SCOPE 2. DESIGN 3. MATERIALS 4. CONSTRUCTION 5. METHOD OF MEASUREMENT AND PAYMENT SCOPE This Specification sets out requirements for the design,

More information

CULTEC STORMWATER CHAMBER SYSTEMS

CULTEC STORMWATER CHAMBER SYSTEMS DRAINAGE SOLUTIONS SINCE 1908 CULTEC STORMWATER CHAMBER SYSTEMS RETENTION / DETENTION / INFILTRATION ENVIRONMENTAL PROTECTION COST-EFFECTIVE LAND USE EASY TO INSTALL ARMTEC.COM CULTEC STORMWATER MANAGEMENT

More information

DS/EN DK NA:2013

DS/EN DK NA:2013 National Annex to Eurocode 6: Design of masonry structures - Part 1-1: General rules for reinforced and unreinforced masonry structures Foreword This national annex (NA) is a revision and compilation of

More information

CHAPTER 11: PRESTRESSED CONCRETE

CHAPTER 11: PRESTRESSED CONCRETE CHAPTER 11: PRESTRESSED CONCRETE 11.1 GENERAL (1) This chapter gives general guidelines required for the design of prestressed concrete structures or members with CFRM tendons or CFRM tendons in conjunction

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 3167 Fourth edition 2002-02-15 Plastics Multipurpose test specimens Plastiques Éprouvettes à usages multiples Reference number ISO 3167:2002(E) ISO 2002 PDF disclaimer This PDF

More information

Design Methods of Elements from Cross-Laminated Timber Subjected to Flexure

Design Methods of Elements from Cross-Laminated Timber Subjected to Flexure RIGA TECHNICAL UNIVERSITY INSTITUTE OF STRUCTURAL ENGINEERING AND RECONSTRUCTION A.Vilguts, D.Serdjuks, L.Pakrastins Design Methods of Elements from Cross-Laminated Timber Subjected to Flexure RIGA 2015

More information

Reinforced concrete slot channel

Reinforced concrete slot channel Applicable Bodies of Rules: DIN EN 1433»Drainage channels for vehicular and pedestrian areas«din 19580»Drainage channels for vehicular and pedestrian areas«the following laying instructions are general

More information

BIS or used as Amendment to STANDARD comments is 15 Nov. 2008

BIS or used as Amendment to STANDARD comments is 15 Nov. 2008 Doc: MTD 4 (4730) For comments only BUREAU OF INDIAN STANDARDS Modified draft Indian Standard HOT ROLLED CARBON STEEL SHEET AND STRIP (Sixth Revision of IS 1079) ICS 77.140.50 Not to be reproduced without

More information

Recyclex TRM TURF REINFORCEMENT MAT SPECIFICATION

Recyclex TRM TURF REINFORCEMENT MAT SPECIFICATION Recyclex TRM TURF REINFORCEMENT MAT SPECIFICATION PART I - GENERAL 1.01 Summary A. The Turf Reinforcement Mat (TRM) contains post-consumer recycled polyester fiber for the purpose of erosion control and

More information

Applications. 5 reasons why you should choose Hebden X Grid cellular paving

Applications. 5 reasons why you should choose Hebden X Grid cellular paving 5 reasons why you should choose Hebden X Grid cellular paving The British-made Hebden X Grid cellular paving system can be filled with grass or gravel, then driven over, parked on and walked on whilst

More information

Instructions for installation the GRAF EcoBloc Inspect flex

Instructions for installation the GRAF EcoBloc Inspect flex Instructions for installation the GRAF EcoBloc Inspect flex GRAF EcoBloc Inspect flex Order-Nr. 402005 The points described in these instructions must be observed under all circumstances. All warranty

More information

TENAX t-block retaining wall system for geogrid reinforced block walls

TENAX t-block retaining wall system for geogrid reinforced block walls TENAX t-block retaining wall system for geogrid reinforced block walls T-block system: THE solution for reinforced walls The reinforced soil technique is a construction method that is thousands of years

More information

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7) Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular

More information

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated.

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated. ZGF Partnership Page 1 of 7 SECTION 33 46 00 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes subdrainage systems for foundations and underslab areas. 1.2 SUBMITTALS A. Product Data: For each type

More information

High Modulus Carbon Fibres in Super-Structural Compounds

High Modulus Carbon Fibres in Super-Structural Compounds High Modulus Carbon Fibres in Super-Structural Compounds As a matter of fact, even if composite properties guarantee the best answer to the most severe project requirements, many industrial products can

More information

This European technical approval

This European technical approval Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating

More information

AESTUVER fire-protection mastic For the AESTUVER expansion joint M

AESTUVER fire-protection mastic For the AESTUVER expansion joint M fermacell AESTUVER product data sheet For the AESTUVER expansion joint M Product is an elastic RTV-1 silicone combined with halogen-free fire retardants. Silicone is a versatile elastomer which is mainly

More information

ISO 1401 INTERNATIONAL STANDARD. Rubber hoses for agricultural spraying. Tuyaux en caoutchouc pour pulvérisation agricole. Third edition

ISO 1401 INTERNATIONAL STANDARD. Rubber hoses for agricultural spraying. Tuyaux en caoutchouc pour pulvérisation agricole. Third edition INTERNATIONAL STANDARD ISO 1401 Third edition 1999-12-01 Rubber hoses for agricultural spraying Tuyaux en caoutchouc pour pulvérisation agricole A Reference number ISO 1401:1999(E) ISO 1401:1999(E) Contents

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 21138-3 First edition 2007-10-15 Plastics piping systems for non-pressure underground drainage and sewerage Structured-wall piping systems of unplasticized poly(vinyl chloride)

More information

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 863 REINFORCED SOIL SLOPES. October 19, 2012

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 863 REINFORCED SOIL SLOPES. October 19, 2012 STATE OF OHIO DEPARTMENT OF TRANSPORTATION 863.01 Description 863.02 Materials 863.03 Construction 863.04 Method of Measurement 863.05 Basis of Payment SUPPLEMENTAL SPECIFICATION 863 REINFORCED SOIL SLOPES

More information

HIGH QUALITY Handrails

HIGH QUALITY Handrails HIGH QUALITY Handrails reliable and Safe Semperit developing, manufacturing and installing handrails for more than 60 years. Our know-how, experience and the quality of our products make us one of the

More information

The Road Authority ADS Nyloplast Stormwater Drainage System http://www.roadauthority.com/database/product.asp?prod=4241 28/04/2010 ADS Nyloplast Stormwater Drainage System Engineered PVC surface drainage

More information

Deutsches Institut für Bautechnik

Deutsches Institut für Bautechnik Deutsches Institut für Bautechnik Anstalt des öffentlichen Rechts 10829 Berlin, Kolonnenstraße 30 L Tel.: +49(0)30-78730-0 Fax: +49(0)30-78730-320 e-mail: dibt@dibt.de Ermächtigt und notifiziert gemäß

More information

Deutsches Institut für Bautechnik

Deutsches Institut für Bautechnik Deutsches Institut für Bautechnik Anstalt des öffentlichen Rechts 10829 Berlin, Kolonnenstraße 30 L Tel.: +49(0)30-78730-0 Fax: +49(0)30-78730-320 e-mail: dibt@dibt.de Ermächtigt und notifiziert gemäß

More information

Firestone Polyiso Boards

Firestone Polyiso Boards Firestone Polyiso Boards Superior energy efficiency. Superior protection. Firestone Polyiso Boards POLISOBROUK10.indd 1 1/04/10 14:26 Firestone Polyiso Boards Firestone total roofing systems Since Firestone

More information

ISBN Verlag Ernst & Sohn - Berlin. Preliminary remarks... VI. 1 Introduction...1

ISBN Verlag Ernst & Sohn - Berlin. Preliminary remarks... VI. 1 Introduction...1 Seite 1 Inhaltsverzeichnis und Vorwort Structural Bearings ISBN 3-433-01238-5 Verlag Ernst & Sohn - Berlin Contents Preface...V Preliminary remarks... VI 1 Introduction...1 1.1 History...1 1.2 Terms and

More information

TECHNYL A 205F. Key Properties. Description. Benefits. Applications. Product Data Sheet. Regional Availability

TECHNYL A 205F. Key Properties. Description. Benefits. Applications. Product Data Sheet. Regional Availability TECHNYL A 205F Description TECHNYL A 205F is an unreinforced polyamide 66 for injection moulding. It is available in natural color. Key Properties General purpose Fast cycle High fluidity Benefits The

More information

R-TANK SPECIFICATIONS

R-TANK SPECIFICATIONS TECHNICAL STORMWATER MANAGEMENT R-TANK SPECIFICATIONS PART 1 GENERAL 1.01 Related Documents A. Drawings, technical specification and general provisions of the Contract as modified herein apply to this

More information

SEPTIC TANK CONSTRUCTION GUIDELINES

SEPTIC TANK CONSTRUCTION GUIDELINES SEPTIC TANK CONSTRUCTION GUIDELINES Septic tank for this airport will be designed/ built by the general contractor of the building facilities. At the time of the project design, availability of a septic

More information

European Technical Approval ETA-03/0038

European Technical Approval ETA-03/0038 Deutsches Institut für Bautechnik Anstalt des öffentlichen Rechts Kolonnenstr. 30 L 10829 Berlin Germany Tel.: +49(0)30 787 30 0 Fax: +49(0)30 787 30 320 E-mail: dibt@dibt.de Internet: www.dibt.de Mitglied

More information

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM SECTION 32 32 23 SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM PART 1: GENERAL 1.01 Scope Work includes furnishing all materials, labor, equipment, and supervision to install a Stonebridge segmental

More information

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO SECTION 07220 - ROOF INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: The Roofing Contractor will provide all polyisocyanurate insulation and high density wood fiber roof insulation (tapered

More information

MACHINE-LAY Installation Manual

MACHINE-LAY Installation Manual MACHINE-LAY Installation Manual PaveDrain Installation Manual Table of Contents Section 1: Base Preparation (pages 3 6) Section 2: Machine-Lay PaveDrain Blocks (pages 8 11) Section 3: Edge Restraints (pages

More information

RETAINING WALL SYSTEM. ViaWall. ViaWall A. ViaWall B. ViaBlock

RETAINING WALL SYSTEM. ViaWall. ViaWall A. ViaWall B. ViaBlock RETAINING WALL SYSTEM ViaWall ViaWall A ViaWall B ViaBlock Table of contents Introduction page 1 ViaWall type A Elements of the system 1. Reinforced concrete panel 2. Reinforcing meshes 3. U-bolts Additional

More information

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board Member of Kiwa Nederland B.V. www.eota.eu Sir Winston Churchilllaan 273 NL-2288 EA Rijswijk Postbus 70 NL-2280 AB Rijswijk Tel.: +31 (0)88 998 44 00 Fax: +31 (0)88 998 44 20 E-mail: info@kiwa.nl European

More information

PERSPECTIVES IN PLASTICS

PERSPECTIVES IN PLASTICS PERSPECTIVES IN PLASTICS Welcome to the world of plastics of PiO Let s achieve things together! Our philosophy WE WOULD LIKE TO BE A RELIABLE PARTNER FOR OUR CUSTOMERS PiO is specialized in delivery and

More information

4.8. Subsurface Infiltration

4.8. Subsurface Infiltration 4.8. Subsurface Infiltration Subsurface infiltration systems are designed to provide temporary below grade storage infiltration of stormwater as it infiltrates into the ground. Dry wells, infiltration

More information

DEUTSCHE NORM December 2000

DEUTSCHE NORM December 2000 DEUTSCHE NORM December 2000 Tape and shrinkable materials for the corrosion protection of buried or underwater pipelines without cathodic protection for use at operating temperatures up to 50 C { 30672

More information

Bemis Laboratory Services

Bemis Laboratory Services Bemis Laboratory Services Kilbeggan Road, Clara, Co. Offaly Testing Laboratory Registration number: 263T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule

More information

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description January, 2009 Sarnafil TS 77-15 Polymeric membrane for roof waterproofing Construction Product Description Uses Characteristics / Advantages Approval / Standards Sarnafil TS 77-15 (thickness 1.5 mm) is

More information

PERMEABLE INTERLOCKING PAVERS

PERMEABLE INTERLOCKING PAVERS PERMEABLE INTERLOCKING PAVERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subgrade Preparation B. Placement of Storage Aggregate C. Placement of Filter Aggregate D. Placement of Bedding Course E. Placement

More information