1 Applicator Manual Issue May 2015

2 Contents Introduction 2 Roof Restoration Product Range 3 Roofs Suitable for Restoration 4 Equipment & Application Technique 8 Product Data 10 Notes 11 Glossary of Roof Terms 12 Introduction Since releasing 962 Roof Membrane in 1998, Dulux AcraTex has continued to develop and extend its professional roofing range providing Residential Roof Restoration and Commercial Roofing applicators a full premium system offer. In 2013 Dulux AcraTex took roof coatings to a new level with its advanced cross linking formula delivering: Easier spray application. Longer lasting gloss. Truer colours that last longer. As the largest and most trusted coatings company in Australia, Dulux has the professional roofing applicator covered with the technology and business support package to compliment your project offer: High Build Next Gen Barrier Protection. Full technical range for concrete tile or metal roofing. Dulux colour, confidence and warranty. Choice of conventional or Cool Roof colour options. Manufacturing Pedigree All Dulux AcraTex premium quality products are manufactured to exacting specifications. All the products in the Dulux AcraTex Next Generation Roof Restoration System are manufactured in compliance with the following stringent certification systems: Manufacturing Facility: AS/NZ ISO 9001:2000 accreditation AS/NZ ISO 14001:2000 accreditation NATA certified laboratory to ISO Standard ISO/IEC R&D in world class ISO, QS and NATA Accredited Laboratories Introduction Applicator Manual

3 Roof Restoration Product Range is a very effective, low toxicity, anti-bacterial, anti-fungal and anti-algal solution which will destroy all known film spoilage. Roof Sealer WB A water based sealer used to unify and consolidate correctly prepared concrete roof tiles ensuring maximum adhesion and providing an excellent key for. Roof Sealer SB A deep penetrating solvent based sealer used to consolidate correctly prepared weathered, powdery or friable concrete roof tiles, providing an excellent key for. Roof Primer Surfacer (High Build) A waterbased primer engineered for excellent adhesion and filling properties used on correctly prepared heavily pitted / porous tiles. Roof Surfacer provides an excellent base for improved gloss levels on such tiles. Roof Primer MX A quick drying, light grey water based primer which provides excellent adhesion to suitably prepared new or weathered galvanised / Zincalume surfaces and Colorbond Roofs. Roof Bond GI A quick drying highbuild, high TSR water based primer for suitably prepared new or weathered galvanised / Zincalume surfaces. Specifically designed for use under Cool Roof Commercial for maximum solar reflectance. Colours A water based, elastomeric high build coating for application to concrete roof tiles and metal roofs. provides ultimate protection, durability, colour retention and weather proofing. is available ex-stock from selected Dulux Trade Centres throughout Australia in an extensive range of colours, as listed below. Cool Roof Residential (Colours) A limited number of factory manufactured colours using InfraCOOL Technology to achieve a high degree of solar reflectance. By reflecting more of the sun s energy InfraCOOL colours can keep surfaces cooler to help reduce heat build up in roof spaces that can filter into living zones. The extent to which InfraCOOL may translate to internal benefits in each situation will depend on variables such as colour, choice, building design, insulation and location. For Full information refer to the Dulux AcraTex Cool Roof Colour Card. Cool Roof Commercial (White) Dulux Cool Roof Commercial (White) reflects up to 90% of the sun s total light energy, maximises reflection of both visible (colour) and invisible (infra red) radiation, providing maximum roofing surface cooling efficiency. AcraGlaze WB A clear, gloss finish formulated on a pure acrylic emulsion. Used to overcoat suitable unglazed terracotta roof tiles, AcraGlaze WB enhances the tile colour and protects the finish against dirt collection and atmospheric pollutants. Note: Owing to the variable nature of terracotta tiles, no warranty is provided over terracotta roofing. Semi Glazed or Glazed terracotta tiles are unsuitable for coating. Users are advised to test unglazed terracotta tiles for suitability to satisfy themselves prior to coating. Cream Merino* Birch Grey* Bluegrass* Torres Blue* Mountain Blue* Wheat Afghan Burlap Sienna* Terracotta* Dark Terracotta* Mist Green* Rivergum* Caulfield Green* Tuscan Red Mid Brown Dark Brown Brunswick Green Mid Brunswick Green* Iron Bark* Homestead Clay Brick Monarch Light Grey Mid Grey* Dark Grey* Heritage Red* Ferric Red Indian Red* Twilight Shadow Charcoal* Slate Grey* Off White White Ebonite* *Can be ordered in Cool Roof with InfraCOOL Technology. Printed colours are designed to provide inspiration for your colour selection. As colour accuracy is limited by the printing process, your Dulux AcraTex Professional can provide samples of your final selection in real colour to ensure your total satisfaction. Other Colours Colour Matching Dulux AcraTex can be tinted to a wide range of colours upon request. When matching a specific colour, it is recommended that a sample is shown to our Trade Store staff for a match. This is especially important when requesting a match to a proprietary colour, as these can vary from batch to batch. The minimum order quantity for factory matching a specific colour is 12 drums (12 x 15L). Introduction acratex.com.au 3

4 Roofs Suitable for Restoration Not every roof is suitable for restoration. Check to ensure that each roof is suitable before commencing. Areas of greatest concern include sites affected by harsh atmospheric conditions and polluted areas such as seaside and industrial locations. Such conditions will affect the soundness and surface quality of roof tiles. 1. Concrete Roof Tiles: Inspect the roof and the tiles physical condition. This will determine the preparation required for the surface coating. The common types of concrete roof tiles in the market place are highlighted below. Old Tiles (poor cement compaction) 1.1 Old Tiles with Poor Cement Compaction. Before starting roof preparation, check inside the roof cavity for telltale signs of previous leaks and water transmission through the tile. Old tiles may present issues after water blasting by stripping off the barrier of protection which includes many years of moss, lichen and grime, to expose a rough substrate. Roof Primer Surfacer If restoration is carried out, special attention whilst spraying this type of tile is recommended. Generally these tiles are very rough and will absorb far more Roof Primer Surfacer and Roof Membrane Next Generation to produce an even glossy appearance. 1.2 Machine Made, Weathered Cement Tile with Good Cement Compaction. Whether the tile is an old or new, machine made tiles are generally sturdy and are considered more suitable for the restoration process. There are four main categories: a) New or as new tile: The surface has retained its gloss and seal of original protective glaze coat after cleaning. Sound Tile Little or no oxide remaining Machine Made Tiles (good cement compaction) Pitted Aged Tile No oxide colour remaining New or As New Tile b) Sound tile: The surface has retained some of its coloured oxide coat and does not have a loose, friable surface after cleaning. c) Pitted aged tile: The surface has no oxide remaining after cleaning and some of the concrete slurry has been removed from between the aggregate. The surface is porous, requires filling and provides a mechanical key for the Roof Primer Surfacer. d) Powdery or friable tile: The tile surface has an unstable, powdery layer exposed after cleaning. Scratching the surface with your fingernail can test this. To penetrate, seal and consolidate friable tiles it is essential to use Roof Sealer SB or Roof Sealer WB, enabling excellent inter-coat adhesion for Next Generation Roof Membrane. Roof Sealer WB Roof Primer Surfacer Fine Coat of Roof Sealer WB Roofs Suitable for Restoration 2. Terracotta Tiles: Note: Owing to the variable nature of terracotta tiles, no warranty is provided over terracotta roofing. Semi Glazed or Glazed terracotta tiles are unsuitable for coating. Users are advised to test unglazed terracotta tiles for suitability to satisfy themselves prior to coating. Inspect the roof and the tiles physical condition. This will determine the preparation required for the surface coating. The common types of terracotta roof tiles in the market place are highlighted below: a) Vitrified and Glazed Terracotta Tiles: Apart from treatment of moss and a high pressure clean there is no coating recommended for semi glazed, glazed or vitrified tiles. b) Unglazed Terracotta Tiles: The tile has accumulated moss and lichen and lost its original appeal. The roof can be revitalised with the application of the water-based AcraGlaze WB relative to applicators own site testing and acceptance that no Dulux warranty is provided. For full product detail refer to Individual Product Data Sheets. Semi-glazed and Glazed Terracotta Tiles (no warranty provided) Test to confirm suitability Unglazed AcraGlaze WB AcraGlaze WB Applicator Manual

5 Surface Preparation Concrete roof tiles & terracotta tiles To ensure long term aesthetics and protective coating of any roof surface, it is imperative for the system to achieve maximum adhesion through correct surface preparation. (Check State Authorities for Work at Heights and Disposal Regulations). 1. If downpipes are connected to rain water tanks, disconnect these before the cleaning process starts and ensure run-off complies with local regulations. 2. Check vents in the ceiling and cover to eliminate water damage by high-pressure water cleaning. 3. Protect adjacent property/vegetation for the entire restoration process. 4. High-pressure water blast roof at a minimum 3000 PSI to remove dirt, excess grime, lichen, moss and other contaminants. 5. Replace any cracked, chipped or faulty tiles and reset any displaced tiles or ridge capping as required. Repoint where required using Selleys Point Works. 6. Replace any faulty valley irons as required. 7. Mask or cover pergolas, solar panels, skylights etc. susceptible to overspray. Coating Procedure Concrete Roof Tiles 1. Consider tile design and condition after high pressure wash to confirm the appropriate priming system. The selection of primer/sealer will depend on the condition of the tile following pressure cleaning. If the tile is virtually new with a sound well adhered factory coating, a fine coat (see Theoretical spreading rates ) of water-based Roof Sealer WB should be used. The membrane coats can then be applied. If the factory coating is mostly or completely removed by washing but the tile surface remains sound without any loose friable areas, then Roof Sealer WB should be used. If the surface is friable then the Roof Sealer WB or Roof Sealer SB can be used. Note: Care must be taken when priming a mixed tile roof (new and old tiles). Mixed rates of application may be required i.e. a fine coat on the new tiles and a conventional application rate on the old, pre-existing tiles. 8. Coastal requirements may require washes between coats. Sterilising treatment (PrepTreat) Fungal and algae spoilage must be completely destroyed before re-coating; otherwise the growth may continue beneath the film resulting in potential adhesion failure, voiding any warranty. 1. Use an atomiser spray or airless spray unit (low pressure) to apply Prep Treat Solution to the entire roof area. Pay particular attention to the tile noses and joints. 2. To ensure proper treatment and to kill the growth, the sterilising solution should be left for a minimum of 2 hours to dry before overcoating. DO NOT RINSE OFF. Note: A repeat application may be required for heavy infestation. All plants and vegetation should be protected to avoid any contamination and possible poisoning. Prevent entering storm water, sewer drains and water tanks. 2. The coating system shall commence with the application of either Roof Sealer WB, Roof Primer Surfacer or Roof Sealer SB by airless spray, depending upon condition of the tiles. Allow 2 hours (at 25 c and 50% relative humidity) before re-coating. Note: Drying times will vary depending upon prevailing conditions, eg. temperature, roof colour, wind, film thickness etc. If film build is greater than the published theoretical, allow more drying time. 3. Apply the first coat of by airless spray, starting at the ridges and working your way down the roof. Ensure all the noses and hips are coated at this stage, then the faces of the tiles followed by all remaining areas. Allow a minimum of 2 hours before re-coating. 4. Apply the second coat of Next Generation Roof Membrane, ensuring consistent even passes and even film build. 5. For application techniques refer (Application Section). Coating Procedure Suitable Terracotta unglazed roof tiles AcraGlaze WB must only be applied in air temperatures between 10 C and 30 C and must be protected from rain and frost for the first 48 hours. A freshly applied coat of AcraGlaze WB is sensitive to early water and may whiten or go milky if effected by rain or heavy dew before curing. 1. Ensure the surface is cleaned, dry and free of all contaminants. Tiles must be dry. 2. Apply the first light coat of AcraGlaze WB by airless spray, starting at the ridges and working your way down the roof. Ensure all the noses and hips are coated at this stage, then the faces of the tiles followed by all remaining areas, maintaining consistent application and wet film build. 3. Apply the second & third coats of AcraGlaze WB, ensuring consistent even passes and even film build. 4. Application commenced on a single area must be completely uninterrupted. 5. For application techniques refer (Application Section). For full product detail refer to Individual Product Data Sheets. Roofs Suitable for Restoration acratex.com.au 5

6 3. Previously Painted Surfaces Inspect the roof for adhesion and physical condition. A previously painted roof can be resprayed, but due to the variable nature of the original coating and its adhesion, there will be no warranty. (Cross Hatch Adhesion Test should be performed) See Glossary of Terms. The condition of previously painted roofs will vary greatly depending upon environmental circumstances and age of roof. Re-roofing may be required instead of restoration. 4. Metal Roofing Inspect the roof s physical condition, this will determine the preparation required for surface coating. The common type of metal roofs in the marketplace are: Existing Zincalume, weathered Colorbond or galvanised iron roofs. The condition of these roofs will vary greatly, dependent upon environmental circumstances and age of roof. Re-roofing may be required instead of restoration. Previously Painted Metal Roofing (Galv., Zinc, Factory Coated) Metal as per Section 4 Luxaprime ZP Spot prime 2 coats may be required Roof Sealer WB Roof Primer MX Entire surface Surface Preparation Previously Painted Surface 1. Depending upon roof type, follow both concrete roof tile or metal roofing surface preparation guidelines. Special attention should be paid to the effect of Roof Sealer SB or Roof Sealer WB on the previous coating to determine product suitability. If a substrate is sound, non-porous, not friable and the coating well adhered, preparation with Roof Sealer WB (water based) is recommended. Coat a test area and observe the reaction with the previous coating. Solvent based Roof Sealer SB usually softens the coating and this will return to normal once the solvent has evaporated. When the previous coating is dry, carry out a standard cross hatch adhesion test to ensure the sealer has not lifted the coating. This test is designed for you to determine if the previous coating is durable enough to coat with the AcraTex System. Surface Prepartion Metal Roofing 1. Ensure all screw and nail fixings are fixed correctly. 2. Replace any faulty sheet or valley irons as required. 3. Power tool/wire brush clean all rust affected areas (where applicable) to ensure complete removal. Then broom down to remove all rust contamination and loosely bound material. 4. High pressure water blast the metal roof at a minimum 3000 PSI to remove dirt, excess grime, lichen/moss and all other contaminants. Ensure all flaking and peeling paint is completely removed using a mechanical cleaning device ie. Wire wheel to ensure a sound clean surface.(if Any) 5. Once all rust has been removed, spot prime with Dulux Luxaprime ZP as per manufacturer s recommendations by brush, roller or spray. 6. Once the entire roof is prepared appropriately, the roof should then be completely primed with Roof Primer MX over the entire roof area including areas that have been spot primed previously. 7. Heavily rusted roofs or sections should be replaced. In areas where this is not possible power tool/wire brush clean all rust affected areas (where applicable) to ensure complete removal then apply two coats of Durabuild STE. 8. The should be applied within 24 hours of the Roof Primer MX application. Roofs Suitable for Restoration For full product detail refer to Individual Product Data Sheets Applicator Manual

7 5. Factory Pre-coated & Painted Metal Roofing Including Colorbond or previously pained roofs. The condition of these roofs may vary greatly, dependent upon environmental circumstances and age of roof. Re-roofing may be required instead of restoration. Inspect the roof surface for adhesion and physical condition. A previously painted roof can be resprayed, but due to the variable nature of the original coating and its adhesion, Cross Hatch Adhesion Test should be performed refer glossary. 6. Cool Roof Commercial White A high build, heat reflective cross linking, water based membrane top coat with a semi gloss, low glare, white finish for solar reflection. The condition of Zincalume or galvanised iron roofs will vary greatly, dependent upon environmental circumstances and age of roof. Re-roofing may be required instead of restoration. Metal Roofing (Previously painted, factory coated) Metal Roofing (Galv., Zinc) Luxaprime ZP Spot prime (clean, prepare and spot prime surface rust) Luxaprime ZP Spot prime (clean, prepare and spot prime surface rust) Cool Roof Commercial Roof Bond GI Entire surface Cool Roof Commercial Cool Roof Commercial Surface Preparation Previously Painted or Factory Coated 1. Ensure all screw and nail fixings are fixed correctly. 2. Replace any faulty sheet or valley irons as required. 3. Power tool/wire brush clean all rust affected areas (where applicable) to ensure complete removal. Then broom down to remove all rust contamination and loosely bound material. 4. High pressure water blast metal roof at a minimum 3000 PSI to remove dirt, excess grime, lichen/moss and all other contaminants. Ensure all flaking and peeling paint is completely removed to ensure a sound clean surface. 5. Once all rust has been removed, spot prime with Dulux Luxaprime ZP as per manufacturer s recommendations by brush, roller or spray. 6. Heavy rusted prepared areas will require one to two coats of Dulux Durabuild STE. 7. Once the entire roof is prepared appropriately, the roof should then be completely primed with Cool Roof Commercial at 150 um wet over the entire roof area including areas that have been spot primed previously then followed by a final coat of Cool Roof Commercial at 150 um wet. 8. Heavily rusted roofs or sections should be replaced. Refer to Duspec data sheet and specification for more detail of surface preparation. Warranty only applies to Installers that are Cool Roof Commercial installers Surface Preparation Metal Roofing 1. Ensure all screw and nail fixings are fixed correctly. 2. Replace any faulty sheet or valley irons as required. 3. Power tool/wire brush clean all rust affected areas (where applicable) to ensure complete removal. Then broom down to remove all rust contamination and loosely bound material. 4. High pressure water blast metal roof at a minimum 3000 PSI to remove dirt, excess grime, lichen/moss and all other contamination. Ensure all flaking and peeling paint is completely removed to ensure a sound clean surface. 5. Once all rust has been removed, spot prime with Dulux Luxaprime ZP as per manufacturer s recommendations by brush, roller or spray. 6. Heavy rusted prepared areas will require one to two coats of Dulux Durabuild STE. 7. Once the entire roof is prepared appropriately, the roof should then be completely primed with Roof Bond GI at 150 um wet over the entire roof area including areas that have been spot primed previously. 8. Heavily rusted roofs or sections should be replaced. In areas where this is not possible power tool/wire brush clean all rust affected areas (where applicable) to ensure complete removal then apply two coats of Durabuild STE. (RECOAT TIME 16 Hours) 9. The Cool Roof Commercial should be applied within 24 hours of the Roof Bond GI application. For full product detail refer to Individual Product Data Sheets. Roofs Suitable for Restoration acratex.com.au 7

8 Equipment & Application Technique Next Generation Roof Membrane is applied by airless spray only. (small areas can be brushed ie. flashings, flute pipes, barge cappings and gable ends). Airless spray units are a method of atomising material without the use of compressed air. The material is pumped under high pressure through a supply line to an airless spray gun. The material is forced at high pressure through a small opening at the front of the valve called the orifice or spray tip. The tip restriction (orifice) forms a spray pattern. The break-up of material into small droplets is called atomisation. Spray Tips At a gun setting of approximately p.s.i (Graco 795) Roof Primer MX Roof Sealer WB Roof Sealer SB Roof Primer Surfacer spray tip spray tip spray tip spray tip The shape of the spray orifice determines fan angle and fan width. Under close examination, an airless tip has an elliptical shape ( cat s eye ). The elliptically shaped orifice will form a similar elliptically shaped spray pattern. (Refer to Diagram 2). Diagram 2 By turning the spray tip on the gun to the desired position, the airless tip also generates either a vertical or horizontal spray pattern. This action accommodates different work piece configurations where one pattern may be more effective than another. (Refer Diagram 3). Diagram 3 AcraGlaze WB spray tip spray tip Gun Position Hold the airless spray gun with a firm, but comfortable grip. Use the index and middle fingers to trigger the spray gun. The gun should be a natural extension of the operator s arm. There are two and four finger guns. (Refer Diagram 1). An extension bar or lance is strongly recommended to assist in reducing over spray, uneven coverage and to minimise back strain. Diagram 1 Diagram 3 Distance The fan angle and orifice size of an airless tip affects the spray pattern. Gun tip distance from the substrate also affects the spray pattern. As the gun distance from the substrate increases, the fan width becomes wider, eventually causing an over spray condition and uneven coverage. A gun distance of approximately 300mm produces the best coverage. If the 300mm distance must be exceeded, select a narrower fan width to retain your efficiency. Hold the gun perpendicular to the surface whenever possible to reduce the chance of uneven material coverage. Tilting the gun either up or down will produce a heavy build-up of material on the top or bottom of the spray pattern. Both arching and tilting the spray gun also causes an angle at which the material can bounce off the substrate. (Refer Diagram 4). The gun is either full on or full off. There is no partial triggering or feathering. Timing the triggering movement is the key to an even material coverage on the substrate. Diagram 1 Equipment & Application Technique Applicator Manual Issue 9 Hold gun approx 12 (30cm) from surface Hold straight, both horizontally and vertically to the surface. Tilting will cause uneven poor finish Diagram 4 Trigger after the beginning of the stroke. Release before the end of the stroke to prevent runs. Overlap each pass by half to achieve a even film build Applicator Manual

9 Spray Techniques Move the gun and keep it straight to the surface for a consistent quality finish. Spray Speed The proper spray speed applies a full wet coat application with each stroke, without sagging. The spray movement should be at a comfortable and constant rate. Regular Maintenance 1. Clean out the front of the tip at least twice a day with a solvent soaked brush to keep material from building up and clogging the tip. 2. Check the fluid filters periodically. Clean or replace filters as needed. 3. Between coats, place gun tip in water to avoid paint curing/skinning over tip. Drying Times Fanning will cause an uneven finish. Diagram 5 At 25 C and 50% relative humidity Sterilising Solution (For best results leave to dry for 2 hours before overcoating). Roof Sealer WB Roof Sealer SB Roof Primer Surfacer Four hours Roof Primer MX Roof Bond GI AcraGlaze WB (and fully cured in seven days). Diagram 6 The gun stroke or movement should be started before triggering and the trigger released before the stroke ends. This method provides a lead and lag for more even coverage. Proper triggering also conserves material and prevents excessive material build-up at the beginning and end of each stroke. (Refer Diagram 7). (and fully cured in seven days including InfraCOOL). Cool Roof Commercial (and fully cured in seven days). Note: Times may be longer or shorter relative to film thickness and weather conditions. Recommended dry times are 25 degrees and 50% relative humidity, if recoated before recommended drying times gloss levels on final coat will be reduced. The gun is either full on or full off. There is no partial triggering or feathering. Timing the triggering movement is the key to an even material coverage on the substrate. Diagram 7 Trigger after the beginning of the stroke. Release before the end of the stroke to prevent runs. Overlap each pass by half to achieve an even film build. Equipment & Application Technique acratex.com.au 9

10 Product Data SUBSTRATE & Condition [after High Pressure Wash (HPW) 3000psi min.] Range Type AcraTex Product Not Powdery Concrete Tiles Powdery Pitted Factory Weathered Metal Pre-coated As New Galv & Zincalume Previously Painted* No Flaking Unglazed Terracotta** Glazed Prep Products Cleaning Non Company Refer specialist supplier for suitable Detergent Wash & Mould Treatment. Used in conjunction with HPW 3000 psi (min) Sterilising PrepTreat Primer Sealers Roof Sealer WB Roof Sealer SB Test for suitability Test for suitability Primers & Sealers Primer Surfacer Galvanised Iron & Zincalume Galv/Zinc (Rusted) Metal (Rusted) Roof Primer Surfacer Primer MX LuxaPrime UMP (Light Rust) DuraBuild STE (Rusted) Refer Application Manual for specifications for Rusted Surfaces Not Recommended **Due to the variable nature of terracotta tiles Dulux does not recommend coating with Membrane coatings Topcoats Membrane Heat Reflective Roof Membrane Next Generation InfraCOOL Cool Roof Colour and popular Colorbond Roofing Colours - Refer Colour Card Popular Colours with InfraCOOL Technology - Refer COOL ROOF Residential Brochure Test for suitability Not recommended Not recommended Not recommended Clear Glaze AcraGlaze WB Can be used as a Clear Coat Glaze *Test for suitability *Due to the variable nature of Previously Painted and Terracotta roofing, Dulux offers NO warranty on systems over these substrates Theoretical Spreading Rates Product Spread Rate (m 2 /L Max.) Wet Film Build (Microns Per Coat) Dry Film Build (Microns Per Coat) Gloss Level Sterilising Solution 12 N/A N/A N/A Roof Sealer WB 8 Standard Coat 65 Dust Coat 40 Standard Coat 20 Dust Coat 10 Low Gloss Roof Sealer SB Low Gloss Roof PR Surfacer Low Gloss Roof Primer MX Low Gloss Roof Bond GI 5 150t 75 Semi Gloss AcraGlaze WB Gloss Finish Only Next Generation Roof Membrane Gloss Finish Only Product Data Cool Roof Commercial Semi Gloss Assuming no loss, practical spreading rates will vary due to method and conditions of application and surface roughness. Note: Material allowance needs to be considered to allow for surface porosity and profile variance. Re-coating before the recommended dry time 50% humidity) will potentially reduce the gloss of the final coat. A longer dry time may be required if the temperature is below 25 C or humidity is above 50%. 10

11 Notes Colour It is the applicator s responsibility to ensure consistent colour coverage. Adequate stocks of material shall be delivered to site to complete the roofing area at one time. If two or more batches are used on the same project, it is advisable to premix (box) prior to application in larger containers. Colour may look different from colour card due to tile profile and pitch design of the roof. Climatic Conditions Roof restoration products must only be applied in air temperatures between 10ºC and 30ºC. Application in extreme heat, windy conditions, or if rain is threatening within 4 hours of completion should be avoided. During inclement weather, application should be stopped in sufficient time to allow the product to cure adequately. In some locations around Australia this may be as early as 1 or 2 PM. REMEMBER, where the air temperature is around 10ºC, a concrete surface temperature can be 5ºC. A drop of only 2ºC in air temperature at 85% relative humidity is enough to induce the dew point, thereby terminating the drying process for acrylic products. Always show a degree of care during winter or inclement conditions. A low pitch roof can also be a problem when dew point sets in thus allowing little to no water run off. This can stop the coating fully curing. Sample Reference Area Once the roof preparation has been completed, the applicator should provide a sample/reference area comprised of each component of the preparation stages and specified coating system, conforming to grade and finish, minimum dry film thickness and the approved colour. This On Site sample, of not less than 4 square metres, shall be applied to an area representing typical substrate variation of differing weathered roof tiles and if applicable where roof tiles have been replaced with either new or seconds. The appearance of the finished coating shall, as near as practicable, match the approved On-Site sample in terms of gloss, colour and uniformity. Permissible variation and due regard shall be given to multiple applicators, on site restraints, access limitations, and light angle or illumination accentuating surface irregularities. Useful Coating Hints 1. Inspect the surrounding environment for potential problems, for instance: Guttering, skylights, solar panels, watertanks and transparent fibreglass roofing. All must be masked to avoid over-spray. 2. Consumption of product will vary relative to the substrate absorption, its roughness and profile. Also the method of application will vary the usage. For example, spraying on a windy day will result in loss of product into the air, thus adding to the material usage and job cost. 3. Weather conditions can have a high impact on the time taken on a project. Make adequate provision for inclement weather covering both costs and extension of time. (During winter in colder regions available application hours per day may be reduced). 4. Reconnect down pipes to storage tanks after the first 2 rainfalls, preventing dust, debris and surfactant collection. 7. Use protective gutter guard prior to resting ladder on gutter this will avoid damaging the gutter. 8. When down pipes are disconnected use the Dulux AcraTex lay flat housing to divert water away fom the property ie. grassed areas. 9. Check with Work Cover for use of Roof Scaffolding when quoting work. This may be an extra expense that may have been overlooked. 10. When washing down the roof avoid any water from the pressure cleaning run down the Storm Water. 11. Wear flat rubber soled shoes these will give you the best traction when working on the roof. Best practice is to wear fall prevention apparatus when working at heights. 12. The location of power lines should be kept in mind when working on a roof. 13. Continually check the weather forecast for changes in weather patterns. 14. When replacing broken tiles ensure you use similar aged tiles. New tiles will look different to old tiles when coated. Use of Dulux AcraTex Roof Primer Surfacer will help to blend the new and old tiles. 15. Use a paintable polyurethane mastic or paintable silicone for sealing and gaps. Collection of Drinking Water Dulux AcraTex contains compounds called Surfactants. These are similar to detergents and are vital for colour dispersion. During the curing process which can be up to three months in cooler climates, these compounds migrate to the surface of the coating and are washed off with rain or may be removed by gentle washing with a garden hose. This wastewater, containing the surfactants, can foam in the same manner as washing detergents. Whilst these compounds are not in such a concentration as to cause injury to humans, they may affect fish and other aquatic organisms. To minimise these effects we advise the following: 1. Prior to restoration, disconnect downpipes which are connected to rainwater tanks or direct water into watercourses. 2. Following the coating application leave downpipes disconnected for at least two significant rains or wash the roof after three weeks of curing, depending on drying conditions and rainfall. Use Dulux Acratex lay Flat Hosing to divert water away. Warranty A ten-year material warranty is provided when a Roof Membrane Next Generation system is applied by a Dulux AcraTex Registered Applicator to a suitably prepared roof and in accordance with the current Roof Membrane Next Generation Application Manual and Duspec Data Sheets. The Dulux warranty is conditional upon the applicator providing a separate Applicators Workmanship Warranty, acknowledging application as per the current Dulux AcraTex Application Manual and confirming use of Dulux products. 5. Pay close attention on windy days, ensuring paint overspray does not affect the customer s or neighbouring property ie. Clothes lines, fences and cars. 6. Some products have adverse affects to plant life, eg, so ensure no product is used near plants, grass and water tanks. Use preventative measures. Notes acratex.com.au 11

12 Glossary of Roof Terms Gable Hip Valley Ridge Pitch Flashing Scribing Pointing Gutter Joist Parapet Wall Purlin Weep Holes A triangular portion of the endwall of a building directly under the sloping roof and above the eave line. The inclined external angle formed by the intersection of two sloping roof planes. The internal angle formed by the intersection of two sloping roof planes. Highest point on the roof, represented by a horizontal line where two roof areas intersect, running the length of the area. The slope of the roof plane, referred to as the height of rise over the length of run ie degree pitch. Components used to weatherproof or seal the roof system edges at perimeters, penetrations, walls, expansion joints, valley, drains and other places where the roof covering is interrupted or terminated. Flashing or capping that is cut to match the profile of the roof material ie. Corrugated. A water based compound for the adhesion of ridge tiles to the hips and ridges of roofs. After the ridge tile has been cured into the bedding compound the pointing product is trowled along each edge of the ridge tile. A channelled component installed along the downslope perimeter of a roof to convey runoff water from the roof to the drain leaders or downspouts. Any of the small timber, metal or wood beams arranged parallel from wall to wall to support a floor, ceiling or roof of a building. The part of a perimeter wall immediately adjacent to the roof which extends above the roof. Horizontal secondary structural member that transfers loads from the primary structural framing Small openings whose purpose is to permit drainage of water that accumulates inside a building component. Cross Adhesion Test Conduct an adhesion test on all previously painted surfaces. Ensure surface is sound by cutting a small X through the existing paint with a sharp blade, press cellulose tape firmly across the cut and then rip off the tape. If the paint comes off, it is unsound and should be removed. Repeat at random in a number of areas to test the surface. Step 1 Step 2 Step 3 Cross hatch adhesion diagram Glossary of Roof Terms Applicator Manual

13 For further information go to acratex.com.au Dulux AcraTex Customer Service Jeanes Street, Beverley SA 5009 Australia Dulux AcraTex is a division of DuluxGroup (Australia) Pty Ltd. ABN Dulux, AcraTex, and InfraCOOL are registered trade marks of DuluxGroup (Australia) Pty Ltd. Colorbond and Zincalume are registered trade marks of Bluescope Steel Limited. 6169/0115

Ultimate Roof Protection

Ultimate Roof Protection Ultimate Roof Protection Cream Merino Birch Grey Wheat Afghan Burlap Mist Green Rivergum Caulfield Green Brunswick Green Mid Brunswick Green Iron Bark Light Grey Mid Grey Dark Grey Twilight Shadow Charcoal

More information

Dulux AcraTex Roof Sealer SB Clear

Dulux AcraTex Roof Sealer SB Clear Dulux AcraTex Roof Sealer SB Clear AUDA0476 Part A 194-85752 Image Product Overview Previously known as DULUX AcraTex 501/4 Roof Sealer DULUX AcraTex Roof Sealer Solvend Based is a solvent based, deep

More information

Roofing Applicator System

Roofing Applicator System Roofing Applicator System Features and Benefits Protective membrane UV resistance Drinking water safe Solar reflectance Crack bridging 10 year material warranty Resists pollution Chemical attack Minimise

More information

A range of popular roof shades Spruce Acrylic Roof cannot be tinted.

A range of popular roof shades Spruce Acrylic Roof cannot be tinted. TECHNICAL DATA SHEET Version 1 2017 MARCH THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION A quality, 100% pure acrylic paint for roofs PRODUCT USES Spruce Acrylic Roof is for application

More information

Dulux AcraTex 950 Interior Fine Texture Roller Finish

Dulux AcraTex 950 Interior Fine Texture Roller Finish Dulux AcraTex 950 Interior Fine Texture Roller Finish AUDA1410 Part A 194-20810 Image Product Overview DULUX AcraTex 950 Roll On 00 Interior texture coating is a non-granular, water based acrylic texture

More information

Dulux AcraTex 950 Roll On 00 Fine Texture Roller Finish

Dulux AcraTex 950 Roll On 00 Fine Texture Roller Finish Dulux AcraTex 950 Roll On 00 Fine Texture Roller Finish AUDA0451 Part A 194-20814 Product Overview Previously known as DULUX AcraTex 950 Roll On 00 DULUX AcraTex 950 Roll On 00 texture coating is a range

More information

INSTALLATION GUIDE SPECIFICATION

INSTALLATION GUIDE SPECIFICATION INSTALLATION GUIDE SPECIFICATION FLUID-APPLIED WATERPROOFING (OVER EXISTING METAL ROOF DECK) PART 1 GENERAL 1.01 DESCRIPTION A. Scope Installation of a premium acrylic roof coating system to waterproof

More information

Proposed Purpose Of Use. Scope Of Works. Summary

Proposed Purpose Of Use. Scope Of Works. Summary Dulux AcraTex AcraShield Advance / Dulux AcraTex 955 AcraShield Matt on New Pre Cast Concrete on New Concrete ( Off Form, Tilt Up, Pre Cast ) [Exterior] AU_SA09530 Proposed Purpose Of Use Provide a 100%

More information

Dulux AcraTex VENETIAN PLASTER QUARTZ PRIMER

Dulux AcraTex VENETIAN PLASTER QUARTZ PRIMER Dulux AcraTex VENETIAN PLASTER QUARTZ PRIMER AU_DA02372 Part A 194-X2000 Approvals N/A Description Dulux AcraTex Venetian Plaster Quartz Primer is a primer-sealer for interior / exterior use on porous

More information

Approx. 12 m² per litre depending on surface porosity, profile. Application methods

Approx. 12 m² per litre depending on surface porosity, profile. Application methods TECHNICAL DATA SHEET Version 1 2015 JUNE THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION Versatile multi-surface waterborne primer PRODUCT USES Suitable for use as a primer to appropriately

More information

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification Product Data Sheet Pondseal Waterproofing Membrane for Ponds and Water Features Description Pondseal is a polyurethane / acrylic co-polymer, water based coating which when fully cured, forms an impervious,

More information

Dulux AcraTex AcraShield Advance on New Concrete ( Off Form, Tilt Up, Pre Cast ) [Exterior]

Dulux AcraTex AcraShield Advance on New Concrete ( Off Form, Tilt Up, Pre Cast ) [Exterior] Dulux AcraTex AcraShield Advance on New Concrete ( Off Form, Tilt Up, Pre Cast ) [Exterior] AUSA0770 Description A Mid Build Finishing System for Off Form Concrete. IncorporatingAcraTex 955 AcraShield

More information

Dulux AcraTex Acraprime Water Based

Dulux AcraTex Acraprime Water Based Dulux AcraTex Acraprime Water Based AUDA0441 Part A 194-20809 Product Overview DULUX AcraTex AcraPrime Water Based acrylic primer/sealer conditions the surface and unifies substrate porosity. Features

More information

ROCKGRIP UNIVERSAL ACRYLIC PVA

ROCKGRIP UNIVERSAL ACRYLIC PVA TECHNICAL DATA SHEET Version 1 2016 FEBRUARY THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION Matt finish for interior use PRODUCT USES Suitable for use on primed new or previously painted

More information

THE BRITE THING TO DO

THE BRITE THING TO DO REDUCING ENERGY CONSUMPTION IMPROVING AIR QUALITY THE BRITE THING TO DO BRITE-n-EZ Enhanced Coating Application Process on Black EPDM Roof Membrane BRITE-n-EZ EPDM Application Instructions CLEANING Remove

More information

Flexible Pointing Compound for use on concrete & terracotta roofs. Optional, to build and smooth badly weathered concrete tiles before top coat

Flexible Pointing Compound for use on concrete & terracotta roofs. Optional, to build and smooth badly weathered concrete tiles before top coat ROOFCOTE CRC SYSTEM The Roofcote CRC System includes a full range of components for coating commonly encountered roof substrates. The coating system is fully covered by the Acryloc Manufacturer s Warranty;

More information

PEKAY T570 RUBBERSEAL

PEKAY T570 RUBBERSEAL PEKAY T570 RUBBERSEAL DESCRIPTION Pekay Rubberseal T570 is a rubber-latex modified anionic bitumen emulsion, which dries to a pliable, flexible, waterproof, black coating. It may be used for a variety

More information

RG-170 Elastomeric 15yr System/ Metal Roofs

RG-170 Elastomeric 15yr System/ Metal Roofs RG-170 Elastomeric 15yr System/ Metal Roofs PART 1 - GENERAL 1.01 Description of Work A. This general specification is for the application of a Roof Guardian Technologies (RGT) Elastomeric Coating system

More information

HAMMERITE NO. 1 RUST BEATER PRIMER

HAMMERITE NO. 1 RUST BEATER PRIMER TECHNICAL DATA SHEET Version 2 2018 June THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION Hammerite No.1 Rust Beater provides a high build finish to heavily pitted areas of rust and

More information

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL Part 1. 1.1 Description General Conditions A. Scope of Work Provide all materials, labor and equipment required for the installation

More information

RG180 FIBERED ELASTOMERIC 15yr System/ Metal Roofs

RG180 FIBERED ELASTOMERIC 15yr System/ Metal Roofs RG180 FIBERED ELASTOMERIC 15yr System/ Metal Roofs PART 1 - GENERAL 1.01 Description of Work A. This general specification is for the application of a Roof Guardian Technologies (RGT) Elastomeric Coating

More information

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY SOLAR COATING SYSTEMS 2-PLY EMULSION MULSION/A /ACRYLIC SYSTEM Specification for Built-Up Roofing 07590 PART 1. GENERAL 1.01 SUMMARY Name Address City, State, zip A. Furnish and install a seamless, reinforced

More information

For RSA Coating Systems over For RSA Coating Systems over Austech Foamula Extruded Polystyrene (XPS) (Skin Off)

For RSA Coating Systems over For RSA Coating Systems over Austech Foamula Extruded Polystyrene (XPS) (Skin Off) Austech Foamula Extruded Polystyrene (XPS) (Skin Off) RSA strongly recommend the use of our full render and texture systems with the appropriate water tight membrane over polystyrene products. SEVEN STEPS

More information

ASTEC ANTI-GRAFFITI CLEAR COATING POLYURETHANE SILICONE MODIFIED TYPE. Aliphatic 2 Pack Polyurethane Anti-graffiti coating. PRODUCT DESCRIPTION

ASTEC ANTI-GRAFFITI CLEAR COATING POLYURETHANE SILICONE MODIFIED TYPE. Aliphatic 2 Pack Polyurethane Anti-graffiti coating. PRODUCT DESCRIPTION [ TECHNICAL BULLETIN ] ASTEC ANTI-GRAFFITI CLEAR COATING POLYURETHANE SILICONE MODIFIED Sumolac PRODUCT TYPE Aliphatic 2 Pack Polyurethane Anti-graffiti coating. PRODUCT DESCRIPTION Astec Sumolac is a

More information

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS TECHNICAL DATA SHEET Version 1 2016 SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION A low odour premium quality interior mid sheen finish with supreme stain resistance. PRODUCT

More information

Product Specification

Product Specification Product Specification Product Name: PORTER S MINERAL SILICATE STAIN PRODUCT DESCRIPTION: is a highly durable coloured silicate dispersion stain for the decoration and protection of old and new fair-faced

More information

White, a range of ready-mixed colours, and colours from the Dulux Colour System

White, a range of ready-mixed colours, and colours from the Dulux Colour System TECHNICAL DATA SHEET Version 2 2016 SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION High quality interior or exterior matt finish PRODUCT USES Recommended for exterior and

More information

SECTION FLUID-APPLIED WATERPROOFING

SECTION FLUID-APPLIED WATERPROOFING SECTION 07140 FLUID-APPLIED WATERPROOFING PART 1 GENERAL 1.1 SUMMARY A. Section includes fluid applied rubberized asphalt and/or elastomeric membrane waterproofing; and surface dusting and/or protective

More information

Robust, non solvent, water based, interior wood lacquer with a voc level well below the 2005 Montreal Protocol Guidelines

Robust, non solvent, water based, interior wood lacquer with a voc level well below the 2005 Montreal Protocol Guidelines Material Specialised MSDS Safety Data Wood SheetLacquer Interior SPS SPS1321A-F 1301 Robust, non solvent, water based, interior wood lacquer with a voc level well below the 2005 Montreal Protocol Guidelines

More information

Property Test/Standard Description

Property Test/Standard Description Other Technical Data Sheet 24100;24120;26200 1 24100 VValidationDate). 1 Product description This is a two component, anticorrosive water borne epoxy coating. It is a versatile, fast drying product containing

More information

DULUX WEATHERGUARD FINE TEXTURED

DULUX WEATHERGUARD FINE TEXTURED TECHNICAL DATA SHEET Version 1 2016 JULY THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION A tough, durable exterior coating with Maxiflex that provides lasting elasticity to cover hairline

More information

DURA 500 THERMOPLASTIC FLAT ROOF COATING SYSTEM BY SUPERIOR POLYMERS INC.

DURA 500 THERMOPLASTIC FLAT ROOF COATING SYSTEM BY SUPERIOR POLYMERS INC. SPECIFICATION GUIDELINE FOR SMOOTH ROOF SUBSTRATES INCLUDING MODIFIED BITUMEN, SMOOTH ASPHALT, EPDM, TPO, AND PLYWOOD. Part 1 General Information For the purpose of clarification in this document, the

More information

the SureCoat Roof System.

the SureCoat Roof System. 1 The SureCoat Roof System General Application Essentials CONDITION OF ROOF BEFORE APPLICATION 1. Roof must be structurally sound and leak-free (meaning all SureCoat repairs to leaking areas must be made

More information

3,Rothwell Street, Timaru, South Canterbury. ; : Phone or

3,Rothwell Street, Timaru, South Canterbury.  ; : Phone or ECO-SEAL 100 3,Rothwell Street, Timaru, South Canterbury Email; ideaslab64@gmail.com : Phone +64 3 688 5508 or 0275 239888 Two Pack Flexible Self Priming high hysteresis waterproofing membrane designed

More information

APPLICATION GUIDELINE

APPLICATION GUIDELINE PROVEN ACRYLIC ROOFING SYSTEMdesigned to restore & protect metal roofs METAL To ensure warranty eligibility, each job must be approved by American WeatherStar before it begins. PART 1 GENERAL 1.01 DESCRIPTION

More information

Roof Systems ROOFS. Inspections

Roof Systems ROOFS. Inspections ROOFS Roof Systems Since your roof is overhead, not easily accessible and tends to be out of sight, out of mind, it is particularly necessary to develop and follow a strategy and program for its inspection

More information

PRODUCT SELECTION GUIDE

PRODUCT SELECTION GUIDE PRODUCT SELECTION GUIDE Floor Sealers MasterTop 333 MasterKure 402 MasterKure 404 MasterTop 1116 Mastertop TC 406 Mastertop TC 450 Mastertop TC 471 Mastertop TC 495 Single Pack Two-pack Epoxy Polyurethane

More information

Application Specification:

Application Specification: Application Specification: MR-30-GF20 March 2014 Supersedes 10/11 PART 1 - GENERAL 1.1 SUMMARY DIVISION 07 01 50.61: GACO WESTERN GACOFLEX S-20 ELASTOMERIC SILICONE COATING FOR REHABILITATION OF AGED METAL

More information

Elasto-Kote Installation Guide

Elasto-Kote Installation Guide I Elasto-Kote Installation Guide Ian CONTENTS 1 - About LRS 2 - Summary of Elasto-Kote cold liquid-applied waterproofing systems 3 - Installation manual: Standard Elasto-Kote system 3.1 - Installation

More information

Method Statement. For RSA Coating Systems Over M Grade Expanded Polystyrene (EPS)

Method Statement. For RSA Coating Systems Over M Grade Expanded Polystyrene (EPS) Method Statement For RSA Coating Systems Over M Grade Expanded Polystyrene RSA strongly recommend the use of our full render, texture paint systems over polystyrene substrates. We DO NOT recommend mixing

More information

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY SOLAR COATING SYSTEMS ACRYLIC ROOF RENOVATION 4.5 Specification for Built-Up Roofing 07590 PART 1. GENERAL 1.01 SUMMARY NAME ADDRESS A. Furnish and install a seamless, waterproof spray applied elastomeric

More information

RG180 FIBERED ELASTOMERIC 10yr System/ Metal Roofs

RG180 FIBERED ELASTOMERIC 10yr System/ Metal Roofs RG180 FIBERED ELASTOMERIC 10yr System/ Metal Roofs PART 1 - GENERAL 1.01 Description of Work A. This general specification is for the application of a Roof Guardian Technologies (RGT) Elastomeric Coating

More information

TECHNICAL DATA SHEET

TECHNICAL DATA SHEET Page 1of 5 PRODUCT DESCRIPTION PROPERTIES COLOUR GLOSS LEVEL WEATHERING UT100 2-Pack topcoat is an unmodified acrylic polyurethane designed to maintain maximum appearance for the maximum length of time.

More information

Dulux AcraTex AcraShield Advance /Coventry Coarse / AcraPatch HB for AFS LOGICWALL / on New Fibre Cement Sheet Recessed/Rebated Edge [Exterior]

Dulux AcraTex AcraShield Advance /Coventry Coarse / AcraPatch HB for AFS LOGICWALL / on New Fibre Cement Sheet Recessed/Rebated Edge [Exterior] Dulux AcraTex AcraShield Advance /Coventry Coarse / AcraPatch HB for AFS LOGICWALL / on New Fibre Cement Sheet Recessed/Rebated Edge [Exterior] AU_SA07609 Scope Of Works AFS LOGICWALL EXTERIOR FINISHING

More information

Dynacryl Acrylic Resin Based Protective & Anti-Carbonation Coating For Concrete & Masonry Surface

Dynacryl Acrylic Resin Based Protective & Anti-Carbonation Coating For Concrete & Masonry Surface Technical Data Sheet Dynacryl Acrylic Resin Based Protective & Anti-Carbonation Coating For Concrete & Masonry Surface Description Bostik Dynacryl is a solvent based clear acrylic coating for a protective

More information

V 2.4. Hardwood Decking Installation Manual

V 2.4. Hardwood Decking Installation Manual V 2.4 Hardwood Decking Installation Manual TABLE OF CONTENTS 1. Scope... 2 2. Health and Safety... 3 3. Site Preparation... 4 4. Pre-Installation... 4 5. Fixings... 5 6. Fixing Details for Decking... 6

More information

Zinc Silicate (Inorganic)

Zinc Silicate (Inorganic) Product code: 477-041: part A 477-042: part B General description: Two-component, zinc-ethyl silicate-. Forms a continuous coat of metallic zinc that provides cathodic protection to metal (as in hot galvanization).

More information

838 Coatings System Specification Single-Ply Restoration (838 SPR)

838 Coatings System Specification Single-Ply Restoration (838 SPR) 838 Coatings System Specification Single-Ply Restoration (838 SPR) PART 1 General 1.01 System Description The 838 Single-Ply Restoration System (838 SPR) can be applied to a variety of single-ply manufactures.

More information

Protective: Recommended for offshore environments, refineries, power plants, bridges, buildings, mining equipment and general structural steel.

Protective: Recommended for offshore environments, refineries, power plants, bridges, buildings, mining equipment and general structural steel. Other Technical Data Sheet 15261;15962;15280 1 15962 epoxy VValidationDate). 1 Product description This is a two component polyamine cured epoxy coating. It is a surface tolerant, high solids product.

More information

Dulux AcraTex 968 AcraSkin Low Gloss / Coventry Coarse / 50/50 Mix AcraPatch HB & RenderWall / on New Autoclaved Aerated Concrete (AAC) [Exterior]

Dulux AcraTex 968 AcraSkin Low Gloss / Coventry Coarse / 50/50 Mix AcraPatch HB & RenderWall / on New Autoclaved Aerated Concrete (AAC) [Exterior] Dulux AcraTex 968 AcraSkin Low Gloss / Coventry Coarse / 50/50 Mix AcraPatch HB & RenderWall / on New Autoclaved Aerated Concrete (AAC) [Exterior] AU_SA09532 Scope Of Works A Premium High Build levelling

More information

Approved. Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 29 C IED (2010/75/EU) (calculated)

Approved. Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 29 C IED (2010/75/EU) (calculated) Approved 15261;15962 1,2 15962 epoxy ^(ValidationDate) 1 Product description This is a two component polyamine cured epoxy coating. It is a surface tolerant, high solids product. This product is tintable

More information

Application Specification:

Application Specification: Application Specification: MR-38-GF20 May 2014 Supersedes 10/11 PART 1 - GENERAL 1.1 SUMMARY DIVISION 07 01 50.61: GACO WESTERN GACOFLEX S-20 ELASTOMERIC SILICONE COATING FOR REHABILITATION OF AGED METAL

More information

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING (TO RESTORE SMOOTH MODIFIED BITUMEN/BUR ROOF SYSTEMS) PART 1 GENERAL 1.01 DESCRIPTION A. The scope of this design guideline is to describe the installation

More information

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Cycloaliphatic Amine Epoxy Highly chemical resistant epoxy mastic coating with exceptionally versatile uses in all industrial

More information

Dulux AcraTex Acraprime Solvent Based Clear

Dulux AcraTex Acraprime Solvent Based Clear Dulux AcraTex Acraprime Solvent Based Clear AUDA0442 Part A 194-20801 Product Overview DULUX AcraTex AcraPrime Solvent Based primer/sealer is a deep penetrating sealer/primer for consolidating and unifying

More information

RECOMMENDED DESIGN SPECIFICATION

RECOMMENDED DESIGN SPECIFICATION RECOMMENDED DESIGN SPECIFICATION SILICONE COATED SPF ROOFING 1 General 1.1 Section Includes A. Silicone coated SPF roofing system, including substrate board, roof insulation boards, foam insulation materials,

More information

A. Supplier Qualifications: The ACRYSHIELD SPF Roofing System, as supplied by National Coatings Corporation, is approved for use on the project.

A. Supplier Qualifications: The ACRYSHIELD SPF Roofing System, as supplied by National Coatings Corporation, is approved for use on the project. I. GENERAL ACRYSHIELD SPF ROOFING SYSTEM Installation Guide Specification SPF Vapor Retarder System 07500 Saving Money, Safeguarding the Environment One Roof at a Time. 1.01 SUMMARY A. Provide labor, materials,

More information

PRODUCT INFORMATION SABRESHIELD

PRODUCT INFORMATION SABRESHIELD PRODUCT DATA SHEET ISSUE DATE: JULY 2015 PRODUCT INFORMATION PRODUCT NAME PRODUCT DESCRIPTION SABRESHIELD A heavy-duty, fibre- reinforced, waterproof coating with unique dirt shedding technology, excellent

More information

PU Anti Graffiti Polyurethane Finish

PU Anti Graffiti Polyurethane Finish PRODUCT DESCRIPTION A two pack, aliphatic anti graffiti acrylic polyurethane INTENDED USES Used as a highly durable finish coat with excellent obliteration properties for exterior of tanks, equipment,

More information

Application Guide for. MasterSeal Roof 3500 (MasterSeal M 820 Membrane)

Application Guide for. MasterSeal Roof 3500 (MasterSeal M 820 Membrane) Application Guide for MasterSeal Roof 3500 (MasterSeal M 820 Membrane) Roof slab crack-bridging waterproofing system February 2016 Page 1 of 7 1. Surface Preparation 1.1 Ensure the substrate has properly

More information

Application Guide. PaveCoat

Application Guide. PaveCoat Application Guide PaveCoat This guide has been developed to provide comprehensive preparation and application recommendations for a variety of concrete surfaces. Whilst all endeavours have been taken to

More information

Acrylic/Urethane. Metal Roof Restoration Sample Design Guideline

Acrylic/Urethane. Metal Roof Restoration Sample Design Guideline 1 DG0009-I 04/2017 Metal Roof Restoration Sample Design Guideline Acrylic/Urethane ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax: 972-554-3939 www.itwsealants.com

More information

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 30 C calculated VOC-USA / VOC Hong Kong EPA Method 24

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 30 C calculated VOC-USA / VOC Hong Kong EPA Method 24 Other Technical Data Sheet 27800;27801 1 27800 VValidationDate). 1 Product description This is a two component amine cured pure epoxy coating. It is a fast drying, high solids, high build product. It provides

More information

Property Test/Standard Description

Property Test/Standard Description Approved 720 1,2 720 silicone acrylic ^(ValidationDate) 1 Product description This is a one component physically drying silicone acrylic coating. It is heat resistant up to 600 C. Can be used as primer,

More information

310g aerosol, 250ml tin, 500ml tin, 1L tin, 4L tin

310g aerosol, 250ml tin, 500ml tin, 1L tin, 4L tin Overview White Knight Rust Guard Epoxy Enamel is an effective rust inhibiting topcoat that transforms rust into a professional, long lasting colour finish in one easy step*. Ideal for use on metal fences,

More information

Application Specification:

Application Specification: Application Specification: MR-22-GF20 March 2014 Supersedes 10/11 PART 1 - GENERAL 1.1 SUMMARY DIVISION 07 01 50.61: GACO WESTERN GACOFLEX S-20 ELASTOMERIC SILICONE COATING FOR REHABILITATION OF AGED METAL

More information

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions,

More information

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong Approved 20940;16620 1 20940 epoxy ^(ValidationDate) 1 Product description This is a two component amine cured epoxy coating. It is a fast drying, micaceous iron oxide (MIO) pigmented, high solids, high

More information

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces. Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces. BRANZ Appraised No. 678 Ref: P3200 Rev 1 February 2016 Page 1 of 5 1.0 PREAMBLE:

More information

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Tunnel Painting

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Tunnel Painting 1993 Specifications CSJ 8075-18-005 SPECIAL SPECIFICATION ITEM 4514 Tunnel Painting 1. Description. This Item shall govern for the painting of the walls and ceiling of a tunnel. The intent is to provide

More information

Onduline covers the world. More than 100 countries across the globe

Onduline covers the world. More than 100 countries across the globe Onduline covers the world Onduline was founded in 1950 to manufacture and market the now famous corrugated roofing sheets. The outstanding growth and success of Onduline in the last 60 years has seen the

More information

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING (TO RESTORE METAL ROOF SYSTEMS) PART 1 GENERAL 1.01 DESCRIPTION A. This design guideline is to describe the installation of the ALDOCOAT acrylic reflective

More information

Data Sheet Eco-Smart Membrane WS M1

Data Sheet Eco-Smart Membrane WS M1 Water-based Acrylic WS M1 Elastomeric Waterproofing Membrane is a durable, multi-use, extremely durable acrylic coating. At an ideal wet film thickness of 10-14 mils per coat (8-10 mils dry film finish

More information

Refer to Substrates & Surface Preparation.

Refer to Substrates & Surface Preparation. SELECTION & SPECIFICATION DATA Generic Type Description Features Aliphatic Acrylic Polyurethane High gloss finish with exceptional weathering performance characteristics. Used extensively in virtually

More information

System Recommendation SR0618

System Recommendation SR0618 Ardex Australia Pty Ltd ABN 82 000 550 005 Unit 7, 20 Powers Road, Seven Hills NSW 2147 Australia Telephone + 61 2 9851 9100 Facsimile +61 2 9838 7970 www.ardexaustralia.com System Recommendation SR0618

More information

POLYURETHANE FOAM SAMPLE DESIGN GUIDELINE ACRYLIC

POLYURETHANE FOAM SAMPLE DESIGN GUIDELINE ACRYLIC 1 DG0030-J 04/2017 POLYURETHANE FOAM SAMPLE DESIGN GUIDELINE ACRYLIC ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax: 972-554-3939 www.itwsealants.com

More information

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING (TO RESTORE SMOOTH MODIFIED BITUMEN/BUR) PART 1 GENERAL 1.01 DESCRIPTION A. The scope of this design guideline is to describe the installation of the ALDOCOAT

More information

TOPCOAT System Specifications Corrugated Transite Panels

TOPCOAT System Specifications Corrugated Transite Panels TOPCOAT System Specifications Corrugated Transite Panels Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT System Specifications Corrugated Transite

More information

Introduction. Applications. Everest Facade Advantages

Introduction. Applications. Everest Facade Advantages EVEREST FACADE Everest Façade with Endura Everest Industries Limited Introduction The Everest Commercial Facade System provides a versatile and durable façade which is suitable for an extensive range of

More information

Master-Seal Surface-Applied Waterproofing System

Master-Seal Surface-Applied Waterproofing System P 1/7 INDUSTRIAL ROOFING, INC. Master-Seal Surface-Applied Waterproofing System Master-Seal is a highly effective waterproofing system designed to seal surfaces from water seepage in roofs with minimum

More information

Property Test/Standard Description Solids by volume. ISO 3233 Gloss level (60 ) ISO 2813

Property Test/Standard Description Solids by volume. ISO 3233 Gloss level (60 ) ISO 2813 Other Technical Data Sheet 2063;2064 1,2 2063 epoxy VValidationDate). 1 Product description This is a two component solvent free polyamine cured epoxy coating. It is a general purpose tank lining with

More information

ReflectiClean Acrylic/Urethane

ReflectiClean Acrylic/Urethane 1 DG0009-J 08/2015 Metal Roof Restoration Sample Design Guidelines ReflectiClean Acrylic/Urethane ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax:

More information

Dulux AcraTex 968 AcraSkin Low Gloss

Dulux AcraTex 968 AcraSkin Low Gloss Dulux AcraTex 968 AcraSkin Low Gloss AUDA1392 Part A 19485675-77 Approvals AS4548.1, AS4548.2 : Long Life Coatings for Masonry Product Overview DULUX AcraTex AcraSkin is a high performance weather proofing,

More information

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 2401;3440 1 3440 epoxy VValidationDate). 1 Product description This is a two component amine cured epoxy coating. It is a fast drying, micaceous iron oxide (MIO) pigmented, high solids, high build product.

More information

FLEXITHERM Double layer with Graphite Core Insulation

FLEXITHERM Double layer with Graphite Core Insulation Technical Data Sheet Date March 2016 Replaces June 2014 FLEXITHERM Double layer with Graphite Core Insulation DESCRIPTION: Graphite core insulation is graphite enhanced expanded polystyrene insulation

More information

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING (TO RESTORE EPDM MEMBRANES) PART 1 GENERAL 1.01 DESCRIPTION A. The scope of this design guideline is to describe the installation of the ALDOCOAT Silicone reflective

More information

LIQUID APPLIED WATERPROOF ROOF COATINGS

LIQUID APPLIED WATERPROOF ROOF COATINGS J31 LIQUID APPLIED WATERPROOF ROOF COATINGS To be read with Preliminaries/General conditions. TYPE(S) OF COATING 110 COLD DECK ROOF COATING Substrate: New / existing concrete deck / screed. o Preparation:

More information

Membryl UV stable waterproofing membrane.

Membryl UV stable waterproofing membrane. Technical Data Sheet July 2017 DESCRIPTION is a waterborne elastomeric waterproofing membrane with outstanding long-term UV stability. is an effective anti-carbonation membrane for concrete as it exceeds

More information

Corrugated sheet for single storey, sectional buildings and stables

Corrugated sheet for single storey, sectional buildings and stables Cl/SfB l (4-) Nf9 l l September 2011 l Corrugated sheet for single storey, sectional buildings and stables B5 Corrugated sheet and accessories Cembrit companies have been manufacturing corrugated sheets

More information

Instruction Guide APPLICATION OF CIM TO CONCRETE

Instruction Guide APPLICATION OF CIM TO CONCRETE 23 Elm St., Peterborough, NH 03458 Tel: (800) 543-3458 (603) 924-9481 Fax: (603) 924-9482 Web site: Instruction Guide APPLICATION OF CIM TO CONCRETE 1.0 DESCRIPTION This guide covers the installation of

More information

TECHNICAL DATA. General Purpose Epoxy Mortar Binder

TECHNICAL DATA. General Purpose Epoxy Mortar Binder TECHNICAL DATA General Purpose Epoxy Mortar Binder Epirez 133 Description General Purpose Epoxy Mortar Binder is a truly remarkable product. First developed in 1970, it now has the unique distinction of

More information

Recommended Application Procedures

Recommended Application Procedures Recommended Application Procedures Updated: September, 2016 Balanced Coating Properties StreetBond DuraShield Pavement Coating is an acrylic, waterborne coating specifically designed for application on

More information

TECHNICAL DATA SHEET SIKA RAPID REPAIR MORTAR 25KG

TECHNICAL DATA SHEET SIKA RAPID REPAIR MORTAR 25KG TECHNICAL DATA SHEET SIKA RAPID REPAIR MORTAR 25KG Sika Rapid Repair Mortar is a ready to use [just add water], quick setting mortar, based on special cements. It contains selected aggregates and admixtures

More information

Product Data Sheet. Description. Uses. Suitable Surfaces. Polymer enhanced, pre-blended, bag mix, coarse float render.

Product Data Sheet. Description. Uses. Suitable Surfaces. Polymer enhanced, pre-blended, bag mix, coarse float render. Product Data Sheet Render MaxiCoarse Polymer enhanced, pre-blended, bag mix, coarse float render. Description MaxiCoarse Render is a pre-blended, polymer fortified cement based render mix, formulated to

More information

High strength mortars and concretes are conveniently prepared by combining General Purpose Epoxy Mortar Binder (133) and Epirez Aggregates.

High strength mortars and concretes are conveniently prepared by combining General Purpose Epoxy Mortar Binder (133) and Epirez Aggregates. Epirez 133 Description General Purpose Epoxy Mortar Binder (133) is a truly remarkable product. First developed in 1970, it now has the unique distinction of being the most widely specified epoxy based

More information

Nutech Concrete Range

Nutech Concrete Range Nu-tech Pavecoat H2O is a single pack water-based acrylic concrete sealer and has been developed to achieve excellent penetration and adhesion characteristics to overcome the problems associated with traditional

More information

Westbuild PRO. Rapid Drying Wet Area Waterproofing. Polyurethane (PU) modified, permanently flexible, rapid drying, class III waterproof membrane.

Westbuild PRO. Rapid Drying Wet Area Waterproofing. Polyurethane (PU) modified, permanently flexible, rapid drying, class III waterproof membrane. Westbuild PRO Rapid Drying Wet Area Waterproofing Polyurethane (PU) modified, permanently flexible, rapid drying, class III waterproof membrane. Westbuild PRO Wet Area Waterproofing is highly flexible

More information

NOTE: Components must be stored at 12 C (min) for at least 24 hours prior to use.

NOTE: Components must be stored at 12 C (min) for at least 24 hours prior to use. PUB. NO. 360.5.2002 LEADERS IN CORROSION PREVENTION THE PROTECTION OF STRUCTURAL STEEL AND PIPEWORK USING THE DENSO STEELCOAT 400 SYSTEM INSTRUCTIONS FOR USE Due to the wide variety of structures, access

More information

R4 Fast Setting Cementitious Repair Mortar

R4 Fast Setting Cementitious Repair Mortar Product Data Sheet Edition 13/03/2009 Identification no: 01 03 02 02 001 0 000022 R4 Fast Setting Cementitious Repair Mortar Construction Product Description Sika Rapid Repair Mortar is a one component

More information