Flushglaze Rooflight Installation and Maintenance Manual
|
|
- Joan Gregory
- 6 years ago
- Views:
Transcription
1 Glazing Vision Ltd, Saw Mills Rd, Diss, Norfolk, IP22 4RG. Registered in England & Wales, Reg No Flushglaze Rooflight Installation and Maintenance Manual
2 thankyou For choosing rooflights.com, we are confident your rooflight will provide you with many years of service. what s in the box? In order to ensure optimum performance and fit we recommend that you read through all of the details enclosed in this guide thoroughly before attempting to install your rooflight. Your install guide includes the following information: What s in the box? What you should have received with your delivery. Manufacturing specifications and section drawings of your rooflight(s). Recommendations for constructing your s. Step by step installation guide. Maintenance tips. Important numbers section. Your rooflight should arrive on site in undamaged packaging branded with the Glazing Vision manufacturers logo. Please carefully inspect for damage to packaging and/or unit and contact us within 48 hours from signing the receipt of your delivery if you think any damage may have occurred. A separate box containing the installation hardware should also be received, enclosed within the hardware box for each unit you should find the following: Plastic horseshoe packers including 1mm, 2mm, 3mm and 5mm. No.12 x 2 ½ Button Head Wood screws. Rolls of poly-butyl tape. Flushglaze Everything you need to prepare, fit and maintain your rooflight Anything missing? info@rooflights.com i
3 rooflight product specifications Flushglaze double glazed unit The Flushglaze rooflight is available in double glazed, triple glazed and walk on specifications. Double glazed unit Manufacturer: Type: Variants: Description: Features: Approvals: Glass Specification Frame Finish: Glazing Vision Ltd Fixed Flushglaze Rooflight Double Glazed / Triple Glazed / Walk On Specification Fixed glazing system comprising of powder coated aluminium extrusion and double glazed unit. Designed to be installed between 3 and 70 from the horizontal (1 for Walk On variants) No visible fixings with frameless internal views. No external capping systems required. Approved and certified by the British Board of Agrément (BBA) tested for strength and stability, durability, condensation risk, light and solar transmittance, behaviour during a fire, water resistance, and thermal performance. 6mm clear heat soak tested toughened outer 16mm warm edge black silicone sealed argon filled cavity 6mm clear heat soak tested soft low e toughened inner Inspected to Glazing Vision quality standard TWI001 RAL7015 Slate Grey Akzo Nobel Interpon D1036, minimum 40 micron finish. Applied to Qualicoat standards - Approved Applicator License No Poly-butyl tape forms weatherproof seal Rooflight frame Aluminium clip cover concealing fixings Internal finishes (by others) (by others) External weathered finish (by others) Seals: Combination of silicone, butyl and rubber seals. Drawing References: 402ASS051 Flushglaze Kerb Detail 402ASS001 Double Glazed Flushglaze Kerb Mount Detail 3 MIN pitch (recommended 5 ) 75mm MIN structural Saw Mills Road Diss Norfolk IP22 4RG GLAZING VISION Tel: +44 (0) Fax: +44 (0) sales@glazingvision.co.uk Website: IT IS GLAZING VISION'S POLICY TO CONTINUOUSLY DEVELOP AND IMPROVE OUR PRODUCTS. (supplied) WE THEREFORE RESERVE THE RIGHT TO MODIFY OR CHANGE THE DETAIL DESIGN AT OUR DISCRETION AND WITHOUT PRIOR NOTICE. THIS DRAWING IS COPYRIGHT AND THE SOLE PROPERTY OF GLAZING VISION LTD. THE DESIGNS/INFORMATION IT CONTAINS ARE PRIVATE AND CONFIDENTIAL. IT MUST NOT BE COPIED, EXHIBITED OR COMMUNICATED TO THIRD PARTIES FOR ANY PURPOSE OTHER THAN THAT FOR WHICH IT WAS ISSUED WITHOUT THE WRITTEN PERMISSION OF GLAZING VISION LTD. Whatever the specification, the Flushglaze system is designed to be simple to fit, the rooflight frame should drop over the edge of your pre-constructed s and is secured with a combination of poly-butyl tape and wood screws Third angle projection unless otherwise noted. Tolerances: Rev Revision Description Replaced missing leaders and change spacer Whole numbers = ±1mm size to 16mm M An internally fitted One decimal gasket place ensures = ±0.5mmthat warm internal air does not make contact with the cooler Two frame decimal which places can = ±0.2mm result in condensation build up. All angles 90±0.5 degrees unless specified Updated border reduced top trim length IF IN DOUBT - ASK! DO NOT SCALE N Cut away section (right) indicates how rooflight frame should be positioned on Supplier to deburr & remove sharp corners. Drawn/ Date JamesB JamesB Product: GV Standard Flushglaze Description: Double glazed Flushglaze mo Materials: See Above Finish: Std=RAL7015 Grey, Matt Weight: N/A Quantity: N/A Scale: A4 Drawn B Drawn D Drawing 150mm MIN height (low side) ido not weather top of CERTIFICATE 12/4895
4 rooflight product specifications Flushglaze triple glazed unit Triple glazed unit Manufacturer: Type: Variants: Description: Features: Approvals: Glass Specification Frame Finish: Glazing Vision Ltd Fixed Flushglaze Rooflight Double Glazed / Triple Glazed / Walk On Specification Fixed glazing system comprising of powder coated aluminium extrusion and double glazed unit. Designed to be installed between 3 and 70 from the horizontal (1 for Walk On variants) No visible fixings with frameless internal views. No external capping systems required. Approved and certified by the British Board of Agrément (BBA) tested for strength and stability, durability, condensation risk, light and solar transmittance, behaviour during a fire, water resistance, and thermal performance. 6mm clear heat soak tested toughened outer 12mm warm edge black silicone sealed argon filled cavity 6mm clear heat soak tested soft low e toughened inner 16mm warm edge black silicone sealed argon filled cavity 6mm clear heat soak tested soft low e toughened inner Inspected to Glazing Vision quality standard TWI001 RAL7015 Slate Grey Akzo Nobel Interpon D1036, minimum 40 micron finish. Applied to Qualicoat standards - Approved Applicator License No Poly-butyl tape forms weatherproof seal Rooflight frame Aluminium clip cover concealing fixings Internal finishes (by others) (by others) External weathered finish (by others) Seals: Combination of silicone, butyl and rubber seals. Drawing References: 402ASS051 Flushglaze Kerb Detail 402ASS024 Triple Glazed Flushglaze Kerb Mount Detail Our Triple Glazed Flushglaze system should be installed using the same methods as the standard Double Glazed, the rooflight frame should drop over the edge of your pre-constructed s and is secured with a combination of poly-butyl tape and wood screws (supplied) An internally fitted gasket ensures that warm internal air does not make contact with the cooler frame which can result in condensation build up. 3 MIN pitch (recommended 5 ) 75mm MIN structural Cut away section (right) indicates how rooflight frame should be positioned on. 150mm MIN height (low side) ido not weather top of CERTIFICATE 12/4895
5 rooflight product specifications Flushglaze walk on specification Double glazed unit (Walk On specification) Manufacturer: Type: Variants: Description: Features: Approvals: A Glass Specification Frame Finish: Seals: Glazing Vision Ltd Fixed Flushglaze Rooflight Double Glazed / Triple Glazed / Walk On Specification Fixed glazing system comprising of powder coated aluminium extrusion and double glazed unit. Designed to be installed between 3 and 70 from the horizontal (1 for Walk On variants) No visible fixings with frameless internal views. No external capping systems required. Approved and certified by the British Board of Agrément (BBA) tested for strength and stability, durability, condensation risk, light and solar transmittance, behaviour during a fire, water resistance, and thermal performance. 25.5mm clear heat soak tested toughened laminated outer 14mm warm edge black silicone sealed argon filled cavity 6mm clear heat soak tested soft low e toughened inner Inspected to Glazing Vision quality standard TWI001 RAL7015 Slate Grey Akzo Nobel Interpon D1036, minimum 40 micron finish. Applied to Qualicoat standards - Approved Applicator License No Combination of silicone, butyl and rubber seals. Typical deck structure level with glazing Poly-butyl tape forms weatherproof seal Rooflight frame Aluminium clip cover concealing fixings Internal finishes (by others) (by others) External weathered finish (by others) Drawing References: 402ASS051 Flushglaze Kerb Detail 402ASS003 Walk On Flushglaze Kerb Mount Detail Design Loadings: Uniform Distributed Load = 1.5kN/m2 Concentrated Load = 2.0kN The Walk On Flushglaze system is designed to installed in the same way as our other variants, however due to the nature of the product and the likelihood that it will be subjected to foot traffic we recommend installing the rooflight on a minimal 1 fall. i1 recommended pitch 75mm MIN structural 150mm MIN height (low side) Do not weather top of The rooflight frame should drop over the edge of your pre-constructed s and is secured with a combination of poly-butyl tape and wood screws (supplied) In order to avoid trip hazards decking is commonly used to raise the accessible floor level so that it sits flush with the height of the glass. Cut away section (right) indicates how rooflight frame should be positioned on. CERTIFICATE 12/4895
6 150mm MIN height constructing your s A Kerb mounting detail PLEASE NOTE: All of the structure to be constructed by the customer. Refer to S0009 for other wall configurations and pitches. If any variables do not match this standard detail, contact Glazing Vision. Fully weathered exterior surface PL Flu Fo B B FALL DIRECTION Required fall and critical dimensions for construction of your s. A KERB SPAN Critical dimension - Customer to specify on order (Includes external weathering) Flat top sealing surface (no steps or undulations exceeding ±2mm) Overall dimension (includes weathering finishes) Internal dimension (excludes internal finishes) Overall dimension (includes weathering finishes) Internal dimension (excludes internal finishes) Check specific product details for pitch requirements INTERNAL VISIBLE OPENING (Dependant on of structural and internal finishes) FALL DIRECTION Along fall Pitches from mm MAX External weathering 75mm MIN Customer to specify on order Internal finishes (to be applied after rooflight installation) SECTION A-A (ENLARGED) KERB PITCH Customer to specify on order (Refer to variant sales drawing for MIN/MAX) Overall dimension (includes weathering finishes) Internal dimension (excludes internal finishes) KERB WIDTH Critical dimension - Customer to specify on order (Includes external weathering) INTERNAL VISIBLE OPENING (Dependant on of structural and internal finishes) Along fall Pitches over 5 For pitches greater than 5 degrees, the pitch must be built into the roof. The must be constructed perpendicular to the roof. SECTION B-B (ENLARGED) Saw Mills Road Diss Norfolk IP22 4NX GLAZING VISION Tel: +44 (0) Fax: +44 (0) sales@glazing-vision.co.uk Website: IT IS GLAZING VISION'S POLICY TO CONTINUOUSLY DEVELOP AND IMPROVE OUR PRODUCTS. AND THEREFORE RESERVE THE RIGHT TO MODIFY OR CHANGE THE DETAIL DESIGN AT OUR DISCRETION AND WITHOUT PRIOR NOTICE. THIS DRAWING IS COPYRIGHT AND THE SOLE PROPERTY OF GLAZING VISION LTD. THE DESIGNS/INFORMATION IT CONTAINS ARE PRIVATE AND CONFIDENTIAL. IT MUST NOT BE, COPIED, EXHIBITED OR COMMUNICATED TO THIRD PARTIES FOR ANY PURPOSE OTHER THAN THAT FOR WHICH IT WAS ISSUED WITHOUT THEIR WRITTEN PERMISSION. Third angle projection unless otherwise noted. Tolerances: Whole numbers = ±1mm One decimal place = ±0.5mm Two decimal places = ±0.2mm Angular = ±0.5 degree IF IN DOUBT - ASK! DO NOT SCALE Supplier to deburr & remove sharp corners Rev A B Increased to A3 dr Amended critical d
7 installing your rooflight Step by step guide to fitting your rooflight! CAUTION! Rooflights can be extremely heavy. Consideration should be made for moving the product onto the roof and extreme care should be taken during installation. step 2 Once you are happy everything will fit, remove the rooflight and place two runs of butyl tape around the underside of the rooflight using the frame recess as illustrated in the Flushglaze section detail (fig. 1) Pre installation checks fig. 1 After checking you are in receipt of the required installation hardware and rooflight(s) it is important to ensure the area of installation is suitably prepared. The area surrounding the aperture should be clear and provide safe access during the installation works. If working at heights, ensure that all safety systems are in place. Kerbs should be checked for specification, dimensional accuracy and the correct fall to ensure water does not pond on the surface of the rooflight. All s should be complete and fully weathered prior to installation. If in doubt, please refer to the guide and rooflight section details featured in this manual. If you are happy that the area is suitably prepared and your s are accurate, you can commence with the installation of your rooflight. step 3 Carefully place the rooflight back onto the, the weight of the unit will ensure enough pressure is applied to compress the butyl tape and form a weatherproof seal. Once in position, remove the clip on covers around the framework (fig. 2) step 1 fig. 2 We strongly recommend that you dry fit the rooflight by placing it onto the before using any of the adhesive tape so that you can ensure that the rooflight fits over the structure. step 4 This allows access to pre drilled holes in the extrusion enabling you to fix the rooflight using the wood screws provided. Any clearance between the inner face of the rooflight frame and can be packed out using the horse shoe packers supplied (fig. 3) This is a good opportunity to check for any pinch points and to see if the rooflight frame fouls any adjacent parts of the building structure. fig. 3
8 maintaining your rooflight Maintain your rooflight to achieve optimum performance year after year Safety Unless you have purchased a Flushglaze rooflight designed specifically for Walk On purposes, you should not walk on the glass surface unless spreader boards are in place. The standard Flushglaze unit is designed to carry maintenance loads and support the weight of one person only, provided spreader boards are used. If you have purchased the Walk On variant of the Flushglaze rooflight - extra care should be taken if you are walking on the unit in wet conditions as glass can become slippery. Cleaning your rooflight The combination of the Flushglaze s unique bonding method and a constructed to at least 3 ensures there is no water ponding on the glass avoiding watermarks and unsightly staining. To clean the glass, any standard glass-cleaning product can be used. Routine cleaning of the powder coated finish must be implemented for the warranty to be valid, and a record of cleaning schedules will be required in the case of a claim. This should be done every 6 months. The best method of cleaning is by regular washing of the coating using a solution of warm water and mild detergent. All surfaces should be cleaned using a soft cloth or sponge, using nothing harsher than natural bristle brushes. If atmospheric pollution has resulted in heavy soiling of the coating, then nothing harsher than white spirit should be used. Under no circumstances should chlorinated hydrocarbons, esters, ketones or abrasive cleaners be used. Routine maintenance Flushglaze rooflights are very robust, but we do recommend that a visual inspection of the unit is carried out at least once every 6 months. You should check the external seals for any degradation and also the finish of the powder coated frame for any damage. If you are unable to do this yourself, rooflights.com offer a full service and maintenance contract for peace of mind. Please contact our Customer Service team who will be happy to arrange this for you. Safe Disposal There are no hazardous materials used in the construction of the Flushglaze. When disposing of the rooflight please recycle wherever possible. The following materials are used to construct the unit: Aluminium extrusion and corner brackets Stainless steel fixings Low modulus silicone Toughened glass panes Polyurethane adhesive Acrylic adhesive Polyester powder coated finish Butyl Tape PVC foam tape Polyethylene backing rod Warm edge spacer bar PVB laminate interlayer (walk on only)
9 important numbers order number gv rooflight serial number Use this page to make note of your order number and your rooflight serial numbers
OPTIWIN MOTURA. Technical Description. Synopsis:
Technical Description OPTIWIN MOTURA Synopsis: 1. Product "OPTIWIN MOTURA" General Description... 2 2. Materials... 3 2.1. Wood... 3 2.2. Surface... 3 2.2.1. Inside... 3 2.2.2. Outer shell... 4 2.3. Glazing...
More informationDomes Pyramids Opening Rooflights Flatglass Rooflights
Domes Pyramids Opening Rooflights Flatglass Rooflights The Roofglaze range of modular rooflights offers a huge variety of solutions for introducing natural light into all kinds of buildings, with options
More informationKingspan Day-Lite Klick
Insulated Panel Envelope Systems Roof Wall Façades Lighting Rooftop PV Coldstore Structural Products Cleanrooms UK & Ireland Kingspan Day-Lite Klick Installation Guide Page 2 Accessories Overview Designation
More informationRepair Maintenance Hangar Phase II August 2010
SECTION 08800 GLASS AND GLAZING PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Monolithic glass. 2. Insulating glass. 3. Mirror glass. 4. Glazing accessories. B. Types of work in this section include
More informationASSEMBLY INSTRUCTIONS
ASSEMBLY INSTRUCTIONS INFINITI 8mm SLIDER/SLIDER WITH SIDE PANEL THIS PRODUCT IS UNIVERSAL. LEFT HAND OPENING ILLUSTRATED. CHANGE THE HAND BY TURNING THE DOOR/SIDE PANEL UPSIDE DOWN. V03.09.2015 BEFORE
More informationKingspan Day-Lite Kapture Data Sheet
Light + Air UK & Republic of Ireland Kingspan Day-Lite Data Sheet KS700DLK, KS1400DLK, KS0DLK 2 Kingspan Day-Lite KS700DLK, KS1400DLK, KS0DLK Application KS700DLK, KS1400DLK, KS0DLK & KS2750DLK rooflights
More informationAqua Swing Tub Door & EX/RT Panel
Aqua Swing Tub Door & EX/RT Panel TUB DOOR AND PANEL INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest
More informationSunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage:
Item Description Smoke Vent Product Information Description: Smoke Vents (Acrylic) provide a double glazed, 100% Impact Modified 0.181" outer lens and a 50% Impact Modified 0.120" inside lens that is hail
More informationEVOK BEFORE YOU BEGIN PRODUCT REQUIREMENTS. A. Summary Of Key Requirements. B. Product Inspection T01-A INSTALLATION INSTRUCTIONS
EVOK INSTALLATION INSTRUCTIONS ACRYLIC BATH K-1704T BEFORE YOU BEGIN Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow
More informationSECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved
SECTION 08 87 13 WINDOW FILM Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2008-2010 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Safety and Security
More informationSECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM
Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING
More informationRS24-10 Single-Section Skylight System
INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980
More informationUniclass G321:G24 L414 CI/SfB (37.41) December Flat Roofing and Waterproofing Systems. Alumasc. Daylighting Systems
Flat Roofing and Waterproofing Systems Uniclass G:G L CI/SfB (7.) December 00 Alumasc Introduction Contents Introduction Alumasc A Range Superior Modular Rooflights Alumasc B Range Standard Modular Rooflights
More informationProduct information VELUX INTEGRA flat roof window CVP with curved glass cover ISD
Edition 1.0 01.02.2017 Product information VELUX INTEGRA flat roof window with curved glass cover ISD ------ 1093 Product description Mains powered, vented window for flat roofs with curved glass cover
More informationFaçade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.
SECTION 09 7710 FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Decorative ½ / ¾ (13mm/19mm) thick prefinished panel with preengineered attachment clip along with hardware
More informationInsulated double and triple glass units, custom-built to specification and manufactured to the highest standards. Insulated glass units
CI/SfB (31.4) Ro Insulated double and triple glass units, custom-built to specification and manufactured to the highest standards Insulated glass units Global Glass - superior quality built-in Global Glass
More informationSECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.
SECTION 10155 TOILET COMPARTMENTS PART 1 GENERAL 1.1 SECTION INCLUDES A. Plastic laminate partitions. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Concealed steel support members. B. Section
More informationProduct information Fixed flat roof window CFP
Edition 1.0 01.10.2014 Product information Fixed flat roof window Product description Fixed (not opening) window for flat roofs Wear-resistant, high quality white PVC frame Low energy insulating glass
More information15YR INNOVATION FRAMES & GLAZING
Designed and developed in one of the most advanced extrusion facilities in Europe, our windows are unique and are a superior-performance PVCu profile system and product range. 15YR GUARANTEE SAFE & SECURE
More informationFully framed glass panels
Fully framed glass panels design elements G1 Fully framed glass panels G1 design The G1 is a fully framed balustrade solution suiting a refined and deliberate architectural style. Rather than minimising
More informationSECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved
SECTION 08 87 13 WINDOW FILM Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2008-2010 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Safety and Security
More informationSECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved
SECTION 08 87 13 WINDOW FILM Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2008-2010 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Safety and Security
More informationAEROFOILS 200AF-450AF. Sun Control Systems
AEROFOILS 200AF-450AF www.luxalon.com Sun Control Systems Luxalon Aerofoils 200AF - 450AF System Description Luxalon wing-shaped panel elements, or fins, combine optimum solar effectiveness with a firm
More information3M Building & Commercial Services. Nomad Optima+ Entrance Matting. Engineered. to last. Introducing the new 3M TM Nomad TM Optima+ Entrance Matting
3M Building & Commercial Services Nomad Optima+ Entrance Matting 5 PERFORMANCE YEAR WARRANTY Engineered to last Introducing the new 3M TM Nomad TM Optima+ Entrance Matting Working hard, looking good As
More informationSECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS
SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,
More informationWE VE GOT YOU COVERED VISIT OBEX AT
WE VE GOT YOU COVERED VISIT OBEX AT WWW.OBEXUK.COM WE VE GOT YOU COVERED OBEX IS COMMITTED TO PROVIDING OUR GLOBAL CLIENTS WITH THE MOST COMPREHENSIVE EPDM MEMBRANE SYSTEM A COMPANY WITH VISION As global
More informationYES SSG TU Vent Window System
YES SSG TU VENT SYSTEM DESCRIPTION 3-1/2" Overall Depth Flat and Pocket Frame Options Variations: Casement Outswing Projected Outswing 1" Glazing Optional Screens YES SSG TU VENT PERFORMANCE FEATURES AAMA/WDMA/CSA
More informationSunWave Prismatic Skylights
Item Description Fixed Skylights Product Information SunWave Prismatic Skylight Options: Class 1 Units offers Acrylic outer lens options in a single*, double, and triple* glazed configuration. 100% Impact
More information1-part polyurethane pourable self levelling floor joint sealant
Product Data Sheet Edition 29/03/2007 Identification no: 02 05 01 01 018 0 000001 1-part polyurethane pourable self levelling floor joint sealant Construction Product Description Uses Characteristics /
More informationSPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide
More informationJI WALL 1150 Insulated panels (PIR core)
JI WALL 1150 Insulated panels (PIR core) Index JI Wall 1150 1 Description 2 Weight and thermal performance 2 Materials 3 A1. External weather sheet 3 A2. Internal liner sheet (Liner profile) 3 A3. Insulation
More informationConstruction. 1-part high performance sealant for flooring. Product Description. Environmental Information. Product Data Sheet Edition _1
Product Data Sheet Edition 2012-03_1 1-part high performance sealant for flooring Product Description Sikaflex PRO 3 is a one part, moisture curing, elastic joint sealant with high mechanical resistance.
More informationEMERALD ROUGHING-IN. A. Summary Of Key Requirements. B. Product Inspection. A.Ordering Information: A. : T01-B 1 INSTALLATION INSTRUCTIONS
EMERALD INSTALLATION INSTRUCTIONS ACRYLIC BATH K-18778T BEFORE YOU BEGIN Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences.
More informationRev. 07 8/15 Please Read Disclaimers:
FiberCorr panels Guidelines 6005.FC Rev. 07 8/15 Please Read Disclaimers: PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION!! These guidelines are provided in good faith to help prevent any problems
More informationHP Partial Fill. Robust, long-lasting protection
1 CONSTRUCTION TYPE: cavity walls HP Partial Fill Cavity Walls Robust, long-lasting protection HP Partial Fill slabs have a robust outer surface, designed to withstand on-site rigours and maintain a clearly
More informationPRESTON HEALTH SERVICES ARCHITECT'S NO. 2700
SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationA. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.
SECTION 08800 - GLAZING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationU-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report
U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report REPORT NO: SIMULATION DATE: 5/25/2016 REPORT DATE: 6/2/2016 Client: Product Line: Specification:
More informationWindows & Doors. change your frame of mind... inliten. aluminium bi-fold doors
Windows & Doors change your frame of mind... aluminium bi-fold doors Welcome Versatile, secure and stylish, bi-fold doors are ideal for both residential and commercial properties. Featuring both a folding
More informationINSTALLATION GUIDE.
INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Canyon Shake counter batten
More informationVAULT ROOFLIGHT SYSTEM
www.brettmartin.com VAULT ROOFLIGHT SYSTEM The next generation in continuous vault rooflight systems Marvault 2 3 Daylight maximised Marvault is a versatile barrel vault rooflight system, glazed in solid
More informationClimaGuard Neutral 70
Guardian ClimaGuard ClimaGuard Neutral 70 Durable Performance Low-E It s not pyrolytic. It s better. Durability and High-Performance ClimaGuard Neutral 70 Same durability as pyrolytics with superior performance
More informationSECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection
SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION
More informationRS32 Multi-Section Skylight System under/over seam clip double diverter
INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series
More informationProduct information Additional window element GIU
Edition 1.0 15.12.2014 Product information Additional window element Product description High quality moulded polyurethane with white lacquer finish Fixed window element (non opening) For installation
More informationWarmer Roof. Transforming conservatory roofs. WarmerRoof
Warmer Roof Transforming conservatory roofs WarmerRoof the easy way to transform your conservatory into a room you can use and enjoy all year round WarmerRoof what is the Warmer Roof? a highly insulated,
More informationPacific Tile Counter Batten and Batten
Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationB. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.
SECTION 102600 - WALL AND DOOR PROTECTION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationMASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.
SECTION 05721 - ORNAMENTAL RAILINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Glass supported railings. B. See Division 5 Section "Metal Stairs" for steel tube railings associated
More informationProduct information Vertical window element VFE
Edition 2.0 01.01.2017 Product information Vertical window element Product description High quality natural pinewood coated with impregnation and layers of water-based white paint or acrylic clear lacquer
More informationSECTION DECORATIVE METAL AND GLASS RAILING
SECTION 05 73 00 DECORATIVE METAL AND GLASS RAILING PART 1 GENERAL 1.1 SUMMARY A) This section includes both standard and custom handrails as shown in the contract drawings. B) These include aluminum,
More informationNon-sag, ultra low modulus, neutral cure silicone sealant for pavements
Product Data Sheet Edition:21/02/2012 Identification no: 020505052020000001 Sikasil 728 NS Sikasil -728 NS Non-sag, ultra low modulus, neutral cure silicone sealant for pavements Construction Product Description
More informationModular Coldroom Installation Manual
Modular Coldroom Installation Manual May 2005 Disclaimer: The information contained in this installation guide is provided "as is". Bromic Pty Ltd does not warrant the accuracy, adequacy or completeness
More informationFire Rated Glazing System Guide
Fire Rated Glazing System Guide FIRE RATED GLAZING SYSTEM GUIDE Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation into
More informationPVC-U: Innovations and product ranges
PVC-U: Innovations and product ranges Be successful with Schüco 4 pillars of success 1 2 3 4 Product innovations Ranges Sales support Marketing Productivity gains Machinery and application technology Speed
More informationALLMET CONTINENTAL INSTALLATION GUIDE
ALLMET CONTINENTAL INSTALLATION GUIDE www.allmet.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Allmet Continental
More informationCOMPOSITE PANEL ROOFLIGHTS - FAIRS
www.brettmartin.com COMPOSITE PANEL ROOFLIGHTS - FAIRS Introduction 2 3 Save energy with natural daylight Daylight not only improves the internal environment of a building but, also significantly impacts
More informationYCW 250 I-Beam Curtain Wall System Installation Manual
Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS INSTALLATION NOTES..................................... Page ii PARTS DESCRIPTION Framing
More informationMore space, more light, a better quality of life: The high insulated folding sliding doors from Schweizer.
More space, more light, a better quality of life: The high insulated folding sliding doors from Schweizer. 2 An easy perspective: Folding sliding doors enable greater transparency. Whether for a modern
More informationStanding Seam Systems. NBS Specification. KingZip SF Standing Seam Roofing System
NBS Specification KingZip SF Standing Seam Roofing System H31 METAL PROFILED/FLAT SHEET CLADDING/COVERING To be read with Preliminaries/General conditions. TYPE OF CLADDING SYSTEM 140 METAL PROFILED CLADDING
More informationSECTION ROOF SPECIALTIES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationVELUX America Inc. SPECIFICATION FOR MODEL FS NO LEAK FIXED SKYLIGHT SECTION UNIT SKYLIGHTS
SECTION 08620 UNIT SKYLIGHTS PART 1 GENERAL 1.01 SECTION INCLUDES A. Performance and product component information for VELUX FS fixed deck mount skylight. B. VELUX Skylight Adhesive Underlayment provided
More informationKONE TransitMaster 120 escalators
OPTIONS AND PLANNING DIMENSIONS KONE TransitMaster 120 escalators KONE TransitMaster product range Well designed and manufactured escalators are a must for today s highly demanding public areas. They are
More informationSECTION SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.
More informationALL-ALUMINUM DOOR & WINDOW FRAMING
ALL-ALUMINUM DOOR & WINDOW FRAMING WITH INTEGRATED ALUMINUM DOOR STOP SECTION 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONTS SPECIFICATION PART 1 GENERAL 1.1 SECTION INCLUDES: A. Prefinished aluminum
More informationMaking Your Own Interior Storm Windows
Making Your Own Interior Storm Windows Windows are great for letting in sunlight during the winter to heat your home, but at night an under-insulated window will usually lose more heat than it lets in
More informationThe S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary
The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM Expanding spaces to the extraordinary Overview Elevation View of a 4-panel Lift & Slide Door System - Stacked Configuration Panda s Lift & Slide Door Systems
More informationInstallation Instructions
Installation Instructions Flue Gas System Basic Kit GA-K - Chimney Flue Gas System for GB125 Oil Condensing Boiler For trained and certified installers Please read carefully prior to installation. 6 720
More informationifix INSTALLATION MANUAL PV flat roof installation system Version
ifix PV flat roof installation system INSTALLATION MANUAL Version 2012-09-06 ifix Installation Manual Version 2012-09-06 Seite 1 Table of contents Table of contents... 1 Special characteristics of ifix...
More informationManSafe for Roofing. Product Selector E-H-SG-EU-001
ManSafe for Roofing Product Selector EU E--SG-EU-001 The Complete Roof Access Solution The Latchways Product Selector is designed to help you identify the part numbers of the products required to provide
More informationSSS009: Substrate Specification Sheet 9 - Render Board
SSS009: Substrate Specification Sheet 9 - Render Board Page 1 of 8 Document: 9993.48 Collection: 116: Substrate Specification Sheets (SSS) Modified: 08/12/2017 11:34 Created: 20/06/2016 12:09 Armourcoat
More informationMODULAR ACOUSTIC FENCING INSTALLATION GUIDE
MODULAR ACOUSTIC FENCING WWW.QUICKBUILTSYSTEMS.COM.AU INSTALLATION GUIDE INTRODUCTION THE QUICKBUILT FENCE SYSTEM IS A SMARTLY DESIGNED MODULAR SYSTEM EASY AND FAST TO INSTALL AND COST EFFECTIVE. // THE
More informationFabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Trapezoidal Plus KS1000 DLTR PLUS 1.3 & 0.8
Fabrications, Safety & Lighting Solutions Kingspan Day-Lite KS1000 DLTR PLUS 1.3 & 0.8 Applications Designed to be an integral part of the Trapezoidal Roof panel system, Kingspan Day-Lite is a range of
More informationJ41 Reinforced bitumen membrane roof coverings
J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. A comprehensive waterproofing system comprising two reinforced bituminous membranes fully adhered to thermal
More informationSpecification. Project Name: Project reference: Written: by: Cathal Quinn Tel:
Project reference: 010050 Specification Written: by: Cathal Quinn Email: cathal@moymaterials.com Tel: 07788 934895 Project Name: Moy Materials Victoria House (4 th Floor) Victoria Road Chelmsford CM1 1JR
More informationREPORT HOLDER: GLASS VICE HOLDINGS LTD. POST OFFICE BOX MAIRANGI BAY, AUCKLAND 0754 NEW ZEALAND EVALUATION SUBJECT:
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3563 Reissued 01/2018 This report is subject to renewal 01/2019. DIVISION: 05 00
More informationRoof Lanterns 2018 keyliteroofwindows.com
Roof Lanterns 2018 keyliteroofwindows.com 10 Year Guarantee 3 Contents Roof Lantern Sizes & Product Codes Why Keylite? Aesthetics Warmth Strength 04 05 07 09 11 4 5 keyliteroofwindows.com Roof Lantern
More informationFreeStyle Linear Drain with Full Mortar Bed Adapter Kit
FreeStyle Linear Drain with Full Mortar Bed Adapter Kit U.S. Patent No. 8,474,068 Patents Pending: Canada & EP Publication No. 2354339 Discard Linear Drain installation instructions and refer to these
More informationwww.percussionplay.co.uk Percussion Play Limited. t. +44 (0)1730 235180 f. +44 (0)1730 235181 e. info@percussionplay.co.uk Registered Office: Harwood House, 43 Harwood Road, London, SW6 4QP. Registered
More informationConstruction Sealants 101 Making the Connections. Building Enclosure Council Austin October 3, 2012
Construction Sealants 101 Making the Connections Building Enclosure Council Austin October 3, 2012 RPM Incorporated Consumer Consumer Industrial 2 Topics Covered Overview of various types of construction
More informationUniversity Apartments on Brooklyn PROJECT MANUAL
Section 122100 Horizontal Louver Blinds University Apartments on Brooklyn PART 1 - GENERAL 1.1 SECTION INCLUDES A. Horizontal slat louver blinds. B. Operating hardware. 1.2 RELATED SECTIONS A. Section
More informationALSPEC ALUMINIUM SYSTEMS TECHNICAL MANUAL
ALSPEC ALUMINIUM SYSTEMS TECHNICAL MANUAL HR500 HIGH PERFORMANCE BALUSTRADE COPYRIGHT This Technical manual remains the property of Aluminium Specialties Group Pty Limited and contains privileged information
More informationPAYING ATTENTION TO DETAIL by Bob Cusumano
PAYING ATTENTION TO DETAIL by Bob Cusumano Painting contractors are often required to install caulk or sealant in exterior joints. Too often, the sealant is simply gunned into the joint until it s filled
More informationExtreme Sealing Tape
Extreme Sealing Tape Technical Data September, 2014 Product Description 3M Extreme Sealing Tape is a family of single coated, pressure sensitive adhesive tapes designed for difficult sealing applications.
More informationSECTIONAL DOOR SYSTEMS
SECTIONAL DOOR SYSTEMS ThermoMark Model 5155»» INSULATED SECTIONAL STEEL»» NON-INSULATED SECTIONAL STEEL»» ALUMINUM FULL-VIEW COMMERCIAL SECTIONAL DOORS Wayne Dalton offers a complete line of Commercial
More informationTWPC DECKING INSTALLATION GUIDE
TWPC DECKING INSTALLATION GUIDE WWW.LUNAWOOD.COM Lunawood Thermo Wood Plastic Composite Decking Installation Guide TWPC Decking Installation Guide Private use only, please consult Lunawood if the object
More informationInstallation Instructions for SuperFast Hurricane
SuperFast Hurricane Installation Instructions for SuperFast Hurricane I. Before You Start / Preparations Please read all the instructions before you begin the installation. Improper installation will void
More informationThis Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.
VIGO INDUSTRIES INSTALLATION GUIDE FOR STANDING SHOWER CABIN (MODEL VG06062) SAFETY PRECAUTIONS This Installation Guide uses the following symbols to indicate important information. Always observe the
More informationProduct information Centre-pivot white-painted roof window GGL
Edition 2.0 13.09.2017 Product information Centre-pivot white-painted roof window Product description High quality natural pinewood coated with impregnation and layers of water-based acrylic white paint
More informationConstruction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description
January, 2009 Sarnafil TS 77-15 Polymeric membrane for roof waterproofing Construction Product Description Uses Characteristics / Advantages Approval / Standards Sarnafil TS 77-15 (thickness 1.5 mm) is
More informationPRODUCT DATA SHEET Sikaflex PRO-3 WF
PRODUCT DATA SHEET 1-PART HIGH PERFORMANCE SEALANT FOR FLOORING DESCRIPTION is a 1-component, moisture-curing, elastic joint sealant with high mechanical and chemical resistance. USES Sikaflex PRO-3 is
More informationHybrid systems. a new concept in composite facade and window systems
HEAD OFFICE Senior Architectural Systems Ltd, Eland Road, Denaby Main, Doncaster, South Yorkshire, DN12 4HA. Tel: 01709 772 600. Fax: 01709 772 601. E-mail: info@seniorhybrid.co.uk BRANCHES Scotland; Unit
More informationOne-part High Performance Sealant for Flooring
Product Data Sheet Edition No. 00 (January 2016) Sikaflex PRO-3 Sikaflex PRO-3 One-part High Performance Sealant for Flooring Construction PRODUCT DESCRIPTION TESTS Sikaflex PRO 3 is a one part, moisture
More informationStructural Performance Tests of VHB Structural Glazing Tapes
3 Performance Tests of VHB Glazing Tapes Technical Bulletin September, 2010 Introduction 3M VHB Acrylic Foam Bonding Tapes have been used worldwide in a variety of applications in the construction industry.
More informationOutline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)
Outline NBS Specification Protec System to PVC Single Ply (Waterproofing Only) This document is a guide to assist in the production of tender documents only and is not project specific. A site survey is
More informationHermetically sealed, fire rated venetian blind unit for doors and panels
Hermetically sealed, fire rated venetian blind unit for doors and panels Slimblind TM Slimblind is an original new product based on a slim Venetian blind sealed hermetically between two pieces of glass
More informationMASCARET Implementation Guide
MASCARET Implementation Guide Edition of August 21st, 2007 PMA by Arval ZA du Pays de Podensac 33720 CERONS - France Tel. +33 (0)5.57.98.14.50 Fax. +33 (0)5.57.98.14.60 commercial@pma.fr www.pma.fr -2-
More informationGlass Metal Design Pty Ltd
Glass Metal Design Pty Ltd OPERATION AND MAINTENANCE MANUAL FRAMELESS GLASS BALUSTRADE TO BALCONIES ASHTON 600-606, Mowbray Road, Lane cove NSW 2066 Builder: Growthbuilt L 9, 100 William Street Sydney
More informationSiding Installation Manual for: Color Natura Rustica 1
Siding Installation Manual for: Color Natura Rustica 1 Ventilated Siding, Principle Ventilated siding systems consist of five main components: 1. Support structure 2. Ventilated cavity 3. Thermal insulation
More informationCI/SfB (23) Suspended Timber Floor Applications Can be used with Floorboards or Tongue & Groove floor paneling Joist end Fitting Aluminium Foil Bubble Insulation General Purpose Insulation Dry Lining Insulation
More information