1 Certificate of Compliance Certificate: (065182_0_000) Issued to: EGS Electrical Group LLC 9377 W Higgins Rd Rosemont, Illinois USA Attention: Mickey Scherer The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Thong Tong Thong Tong PRODUCTS CLASS - C FIXTURES AND FITTINGS-For Hazardous Locations CLASS - C FIXTURES AND FITTINGS-For Hazardous Locations-Certified to U.S. Standards Class I, Division 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F and G; Class II, Division 2, Groups F and G; Class III; Maximum Ambient 55 o C Enclosure rating: 3R, 4, 4X, and IP66 MERCMASTER LED Low Profile MLLED LED Luminaires; rated input voltage VAC, 50/60HZ or VAC, 50/60 Hz; rated power 26W, 35W, and 48W; Cat. No. MLLED, may be followed by A, C, D, R, S, or W, followed by 2, 3, or 4, may be followed by 2, 3, 4 or 5, may be followed by, G5, J1, J3, J5, V5, P5 or D5, may be followed by G, followed by BU or BH, optionally followed by F, and/or 1, 2, 3, 4. Notes: DQD 507 Rev Page 1

2 1. Cat. No. MLLED, may be followed by A, C, D, R, S, or W, followed by 2, 3, or 4, may be followed by 2, 3, 4 or 5, may be followed by, G5, J1, J3, J5, V5, P5 or D5, may be followed by G, followed by BU or BH, optionally followed by F, and/or 1, 2, 3, Marine Outside Type (Salt Water) rating applies to installation in the USA only. 3. Marine Outside Type (Salt Water) rating not valid for equipment with fusing. 4. Luminaire is not intended for mounting with LEDs in Face up orientation 5. Luminaire for marine application in the US is intended to be installed in accordance with CG-259 American Bureau of Shipping and Coast Guard requirements. 6. Enclosure ratings are not valid for equipment with photo controls. Temperature Code: Luminaire Wattage Designated Voltage Driver Max Ambient Temp. Supply Wire Temp. Class I Div. 2 Class II Div. 1& 2 Class III 26W BU 40 o C 90 o C T4A T4A T4A 26W BU 55 o C 90 o C T4 T4A T4 26W BH 40 o C 90 o C T4A T4A T4A 26W BH 55 o C 90 o C T4 T4A T4 35W BU 40 o C 90 o C T4A T4A T4A 35W BU 55 o C 90 o C T4 T4A T4 35W BH 40 o C 90 o C T4A T4A T4A 35W BH 55 o C 90 o C T4 T4A T4 48W BU 40 o C 90 o C T4A T4A T4A 48W BU 55 o C 90 o C T4 T4A T4 48W BH 40 o C 90 o C T4A T4A T4A 48W BH 55 o C 90 o C T4 T4A T4 Simultaneous Class I Div.2 Class II Div. 1 and 2, Class III DQD 507 Rev Page 2

3 APPLICABLE REQUIREMENTS CAN/CSA C22.2 No General Requirements - Canadian Electrical Code Part II. CAN/CSA C22.2 No. 94-M91 - Special Purpose Enclosures CAN/CSA C22.2 No :05 - Degrees of Protection Provided by Enclosure (IP Code) CAN/CSA C22.2 No M Electric Luminaries for Use in Hazardous Locations CAN/CSA C22.2 No Luminaries UL 50, 11 th Ed. - Enclosures for Electrical Equipment ANSI/IEC Degrees of Protection Provided by Enclosures (IP Code) UL 844, 12 th Ed. - Electric Lighting Fixtures for Use in Hazardous (Classified) Locations UL 1598, 3 rd Ed. - Luminaries UL 1598A, 1 st Ed. - Supplemental Requirements for Luminaires for Installation on Marine Vessels UL 8750, 1 st Ed. - Light Emitting Diode (LED) Equipment for Use in Lighting Products MARKINGS The manufacturer is required to apply the following markings: Products shall be marked with the markings specified by the particular product standard. Products certified for Canada shall have all Caution and Warning markings in both English and French. Additional bilingual markings not covered by the product standard(s) may be required by the Authorities Having Jurisdiction. It is the responsibility of the manufacturer to provide and apply these additional markings, where applicable, in accordance with the requirements of those authorities. The products listed are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US (indicating that products have been manufactured to the requirements of both Canadian and U.S. Standards) or with adjacent indicator 'US' for US only or without either indicator for Canada only. Nameplate adhesive label material approval information: The markings are permanently marked on a metal nameplate(s) having a minimum thickness of 0.5mm, securely attached by means of rivets or drive pins engaging bottomed holes. Alternatively, these marking may appear on a CSA Accepted label as follows: Silver-polyester label with type P1410 Pressure Sensitive adhesive manufacturer: TLF Graphics, Suitable for use indoor and outdoor on metal at 100C max. (CSA File number: LR 59850) The main adhesive marking label appears on the external surface of the luminaire and contains the following markings: NAMEPLATE: - Manufacturer s Name or trademark or Master Contract Number adjacent to the CSA Mark. DQD 507 Rev Page 3

4 - Product Designation: MLLED or MERCMASTER LED LOW PROFILE. - Catalogue Number. - Hazardous locations rating. - In addition to Hazardous location rating equipment may be marked: Class I, Zone 2, Group IIC, may be marked Zone 20 and 21, may be marked Zone 22. In accordance with NEC and CEC. - Electrical ratings: voltage, frequency, amperes, and/or watts. - Supply wire temperature. - Maximum ambient temperature. - CAUTION -TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES DISCONNECT THE FIXTURE FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP TIGHTLY CLOSED WHEN IN OPERATION in English and French. - Date coding. - CSA Mark with the adjacent C and US indicators. - "Suitable For Wet Locations" or "Suitable For Wet Loc." (optional). IP66 (optional, for mounting hoods without photocontrols) TYPE 3R, 4, 4X (optional, for mounting hoods without photocontrols) MARINE OUTSIDE TYPE (SALTWATER) FOR USA ONLY (optional) Other Markings: - Luminaire housings provided with fuses shall have an adhesive-backed label located adjacent to the fuseholder, containing the following statement or equivalent: CAUTION: RISK OF IGNITION OF HAZARDOUS ATMOSPHERES REPLACE ONLY WITH X FUSE HAVING THE SAME VOLTAGE AND CURRENT RATING AS THE EXISTING FUSE. The manufacturer is to insert identification of the fuse filled with noncombustible granular material in the space marked x. ALTERATIONS 1. Markings are provided as described above. FACTORY TESTS A factory-wired luminaire shall withstand for 1 minute without breakdown the application of an ac voltage applied between live parts and non-current carrying metal parts. The voltage shall be 1000 V plus twice the rated voltage. As an alternative, a potential 20 percent higher may be applied for one sec. DQD 507 Rev Page 4

5 Supplement to Certificate of Compliance Certificate: (065182_0_000) The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Project Date Description Product Certification History Initial certification of MLLED series luminaire for Class 1 Div 2, Grps A,B,C,D ;Class II Div 1,Grps E,F,G; Class II Div 2, Grps F, G; Class III. DQD 507 Rev Page 1

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2531848 (030391_0_000) Issued to: EGS Electrical Group LLC 9377 W Higgins Rd Rosemont, Illinois 60018 USA Attention: Mickey Scherer The products listed below are

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2715744 (065182_0_000) Issued to: EGS Electrical Group LLC 9377 W Higgins Rd Rosemont, Illinois 60018 USA Attention: Steve Blais The products listed below are eligible

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2701662 Master Contract: 201067 Issued to: Chalmit Lighting A Division of Hubbell Lighting Ltd. 388 Hillington Rd Glasgow, G52 4BL United Kingdom Attention: Mr. George

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1602514 (LR 39156) Master Contract: 212516 Issued to: Rosemount Analytical Inc. Process Analytic Division Solon Research & Development Ctr 6565-P Davis Industrial

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1731876 (078713_0_000) Issued to: Hawke International A Division of Hubbell Limited Oxford St W Ashton-Under-Lyne, Lancashire OL7 0NA UNITED KINGDOM Attention: Andy

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1015065 (078713_0_000) Issued to: Hawke International A Division of Hubbell Limited Oxford St W Ashton-Under-Lyne, Lancashire OL7 0NA UNITED KINGDOM Attention: Andy

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70128861 Master Contract: 229177 (LR 103294) Project: 70128861 Date Issued: 2017-04-04 Issued to: Murata Power Solutions 4118 14th Ave Markham, Ontario L3R 0J3 CANADA

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2700364 (078713_0_000) Issued to: Hawke International A Division of Hubbell Limited Oxford St W Ashton-Under-Lyne, Lancashire OL7 0NA UNITED KINGDOM Attention: Roger

More information

Certificate of Compliance

Certificate of Compliance FF0001 Certificate of Compliance Certificate: 1717515 Issued to: Limatherm SA ul. Tarnowska 1 Limanowa, 34-600 POLAND Attention: Honorata Janik The products listed below are eligible to bear the CSA Mark

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2700364 (078713_0_000) Issued to: Hawke International A Division of Hubbell Limited Oxford St W Ashton-Under-Lyne, Lancashire OL7 0NA UNITED KINGDOM Attention: Andy

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2557737 (LR104031) Master Contract: 182407 Issued to: Hummel AG Lise-Meitner-Strasse 2 Denzlingen, 79211 Germany Attention: Klaus Gehri The products listed below

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Issued to: Festo AG & Co. KG Ruiterstrasse 82 Esslingen, 73734 GERMANY Attention: Mr. A. Ganzenberg The products listed below are eligible to bear the CSA Mark shown with

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70038032 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, 63911 GERMANY Attention: Harald Gollas The products listed below

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2015-12-22 Page 1 of 13 Report Reference # E182560-V4-S35 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R) 2012 +A1:2012, C1: 2009/(R) 2012 + A2:2010/(R) 2012) Amendment

More information

An Urgent Bulletin from CSA International

An Urgent Bulletin from CSA International Ref No: I12-008 Component Acceptance Service No. 52 Date: February 9, 2012 An Urgent Bulletin from CSA International New Service available as of today Apply any time to have your products evaluated Announcing:

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2389070 (LR 034186) Master Contract: 155560 Issued to: Rosemount Analytical Inc. Uniloc Division 2400 Barranca Pky Irvine, CA 92606 USA Attention: Dana Crowley The

More information

An Urgent Bulletin from CSA International

An Urgent Bulletin from CSA International Ref No: I10-125 Wiring Harnesses No. 2 (Supersedes INFORMS Wiring Harnesses No. 1) Date: October 29, 2010 An Urgent Bulletin from CSA International Existing Certification not affected Apply any time to

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2015-09-29 Page 1 of 14 Report Reference # E182560-V4-S20 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R) 2012 +A1:2012, C1: 2009/(R) 2012 + A2:2010/(R) 2012) Amendment

More information

SECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE

SECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE METAL-ENCLOSED BUS MEDIUM VOLTAGE PART 1 GENERAL 1.01 1.02 1.03 1.04 1.05 SCOPE The Contractor shall furnish and install the equipment as specified herein and as shown on the contract drawings. The medium

More information

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466 BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein

More information

RECOGNIZED COMPONENT Constructional Data Report (CDR)

RECOGNIZED COMPONENT Constructional Data Report (CDR) RECOGNIZED COMPONENT Constructional Data Report (CDR) 1.0 Reference and Address Report Number 150611019SZN-001 Original Standard(s) Applicant Information Technology Equipment Safety Part 1: General Requirements

More information

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number PART 1 GENERAL 01 02 03 04 SCOPE Furnish and install Manual Transfer Switches (MTS) and

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-03-30 Page 1 of 12 Report Reference # E186249-A59-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-02-09 Page 1 of 22 Report Reference # E254758-A32-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: ANSI/AAMI ES60601-1 (2005 + C1:09 + A2:10)(Medical

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2015-09-28 Page 1 of 10 Report Reference # E182560-V4-19 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R) 2012 +A1:2012, C1: 2009/(R) 2012 + A2:2010/(R) 2012) Amendment

More information

MATERIAL SPECIFICATION FOR HIGH PRESSURE SODIUM LUMINAIRES FOR UNDERPASS LIGHTING

MATERIAL SPECIFICATION FOR HIGH PRESSURE SODIUM LUMINAIRES FOR UNDERPASS LIGHTING ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS.PROV 2434 November 2016 MATERIAL SPECIFICATION FOR HIGH PRESSURE SODIUM LUMINAIRES FOR UNDERPASS LIGHTING TABLE OF CONTENTS 2434.01 SCOPE 2434.02 REFERENCES

More information

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Daniel Livingston

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Daniel Livingston MD200001 AGENCY DOCUMENTS, ET2401LM Series REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO-13-0706 Daniel Livingston Daniel Livingston September 12, 2013 DOC #: MD200001

More information

T5 Tube UL, cul Pending DLC Pending (T5 Tube is compatible for the traditional ballast tube)

T5 Tube UL, cul Pending DLC Pending (T5 Tube is compatible for the traditional ballast tube) T5 Tube Light Ideal for decorative and ambient lighting in retail outlets, hotels, warehouses, government buildings, and multi-unit residences T5 Tube UL, cul Pending Light DLC Pending (T5 Tube is compatible

More information

BLAZE BASICS 100 LED Tape Light 24V. 18/ft Color Temperature. 2700K, 3000K, 5000K CRI 90+ Dimmable

BLAZE BASICS 100 LED Tape Light 24V. 18/ft Color Temperature. 2700K, 3000K, 5000K CRI 90+ Dimmable diode led a division of elemental LED BLAZE BASICS 100 LED Tape Light UL Listed Field Cuttable 12VDC 24VDC IP20 90 HIGH CRI Item # Project 12V 24V DI12VBLBSC1 DI24VBLBSC1 Voltage 12V 24V Wattage 1.46/ft.

More information

HAZADOUS LOCATION LED FLOOD LIGHT

HAZADOUS LOCATION LED FLOOD LIGHT HAZADOUS LOCATION LED FLOOD LIGHT LED Explosion-Proof Floodlight FL- 80w, 100w, 150 w Class 1 Division 1 Groups C&D 130 Lumens Per Watt Harsh & Hazardous Duty L90 Value 100,000+ Hours Crisp White 5000K

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin January 2014 CEC-2 [rev-8] Page 1 of 8 SUBJECT: Section 2 General Rules CANADIAN ELECTRICAL CODE Administrative Rules The Safety Codes Act and associated regulations

More information

MUSCO ENGINEERING ASSOCIATES Consulting Engineers

MUSCO ENGINEERING ASSOCIATES Consulting Engineers Consulting Engineers website: www.muscoengineering.com 375 Morgan Lane, Unit 307 West Haven, CT 06516 Telephone #: (203) 932-1901 Fax #: (203) 931-1550 email: admin@muscoengineering.com Electrical Equipment

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70025164 Issued to: Vega Grieshaber KG Am Hohenstein 113 Schiltach, Baden-Württemberg 77761 GERMANY Attention: Sebastian Schaller The products listed below are eligible

More information

TallSlateTM Grandee Installation Manual

TallSlateTM Grandee Installation Manual TallSlateTM Grandee Installation Manual PLEASE READ THIS GUIDE COMPLETELY BEFORE INSTALLING OR USING THE SOLAR ELECTRIC MODULES Disclaimer of Liability...2 General Information...2 General Safety...2 TM

More information

PrevaLED Linear, Bar and Area G3

PrevaLED Linear, Bar and Area G3 www.osram.us/led PrevaLED Linear, Bar and Area G3 High efficacy LED s for diffuse ambient lighting Key Features & Benefits High efficacy LED s Parallel design for serial wiring Poke in wire connectors

More information

Descriptive Report and Test Results

Descriptive Report and Test Results Descriptive Report and Test Results MASTER CONTRACT: 266909 REPORT: 700584 Edition 1: August 12, 2016; Project 700584 Albuquerque Prepared by Chase Henson; Reviewed by Ze Guo Contents: Certificate of Compliance

More information

ELECTRICAL INSPECTION BULLETIN (Effective )

ELECTRICAL INSPECTION BULLETIN (Effective ) ELECTRICAL INSPECTION BULLETIN (Effective 2009-02-01) Rule 36-000 Customer Owned High Voltage Installations With the increase in customer own high voltage equipment there appears to be confusion over which

More information

Wilo MC Self Priming, Horizontal Multi-Stage, High Pressure Pumps. Engineering Specification

Wilo MC Self Priming, Horizontal Multi-Stage, High Pressure Pumps. Engineering Specification Wilo MC Self Priming, Horizontal Multi-Stage, High Pressure Pumps Engineering Specification PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install horizontal multi-stage, high pressure, self priming pressure

More information

37-SDMS-01 REV. 03 SPECIFICATIONS FOR

37-SDMS-01 REV. 03 SPECIFICATIONS FOR 37-SDMS-01 REV. 03 SPECIFICATIONS FOR LOW VOLTAGE MOLDED CASE CIRCUIT BREAKERS FOR SERVICE CONNECTIONS This specification is property of SEC and subject to change or modification without any notice CLAUSE

More information

Defender HAZADOUS LED Luminaire

Defender HAZADOUS LED Luminaire Defender HAZADOUS LED Luminaire LED Explosion-proof Floodlight ( FEL-C Series ) Up to 130 Lumens Per Watt Harsh & Hazardous Duty L90 Value 100,000+ Hours Crisp White 5000K Powered By NJZ-FEL-C Series DESIGNED

More information

Equipment Specifications Low Voltage. Active Harmonic Filter

Equipment Specifications Low Voltage. Active Harmonic Filter Equipment Specifications Low Voltage Active Harmonic Filter 1.0 General Description This section contains the design standards, general equipment type and configuration, components, product description,

More information

Ref No: I Date: November 5, 2004

Ref No: I Date: November 5, 2004 Ref No: I04-108 Date: November 5, 2004 INFORMATION TECHNOLOGY AND ELECTRICAL BUSINESS EQUIPMENT NO. 14 Existing Certification not affected New products to certify? Call us today! 1-800-463-6727 Announcing:

More information

Point Eight Power, Inc. Switchgear Specification Low Voltage UL 1558 Metal-Enclosed Switchgear

Point Eight Power, Inc. Switchgear Specification Low Voltage UL 1558 Metal-Enclosed Switchgear Table of Content 1.0 General... 2 2.0 Scope... 2 3.0 Applicable Codes, Standards and Qualifications... 2 4.0 Service and Environmental Conditions... 3 5.0 Construction... 3 6.0 Front Breaker Compartment

More information

SECTION FLUORESCENT LUMINAIRES. The publications listed below form a part of this section to the extent referenced:

SECTION FLUORESCENT LUMINAIRES. The publications listed below form a part of this section to the extent referenced: SECTION 265100 FLUORESCENT LUMINAIRES PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this section to the extent referenced: AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSI

More information

SECTION BUSWAYS

SECTION BUSWAYS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 25 11 BUSWAYS SPEC WRITER NOTE: Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable to the section and

More information

Dec05 Rev A

Dec05 Rev A Product Specification Z-DOK* and Z-DOK*+ Connectors 108-1985 12Dec05 Rev A 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for Z-DOK* and Z-DOK*+ Connectors.

More information

Mar11 Rev B

Mar11 Rev B Product Specification 108-1543 11Mar11 Rev B Header, MATE-N-LOK*, Mini-Universal 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for MATE-N-LOK* mini-universal

More information

Explosion Proof 150 Watt LED Light Fixture w/ Stainless Steel Unistrut Mounting Bracket

Explosion Proof 150 Watt LED Light Fixture w/ Stainless Steel Unistrut Mounting Bracket Explosion Proof 150 Watt LED Light Fixture w/ Stainless Steel Unistrut Mounting Bracket Part #: HBLP-1MLED-WFM Made in the USA The Larson Electronics HBLP-1MLED-WFM light fixture provides operators with

More information

SSL Series 1.2 IP X8 waterproof solution. Product Data Sheet. REV. 0, 2014 August

SSL Series 1.2 IP X8 waterproof solution. Product Data Sheet. REV. 0, 2014 August SSL Series 1.2 IP X8 waterproof solution Product Data Sheet REV. 0, 2014 August General Specification Number of Positions Current Rating Wire Information Voltage Rating Dielectric Withstand Voltage Durability

More information

INSULATION GUARD MEG (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

INSULATION GUARD MEG (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A. INSULATION GUARD MEG-1000 (Code 2 28 981) INSTRUCTION MANUAL ( M 981 220 / 99A ) (c) CIRCUTOR S.A. ----- Insulation guard MEG-1000 -------- M - 981 220 --- Page nº 1 Insulation guard MEG-1000 1.- BASIC

More information

LARSON ELECTRONICS, LLC US-HWY 175 Kemp, Texas USA

LARSON ELECTRONICS, LLC US-HWY 175 Kemp, Texas USA LARSON ELECTRONICS, LLC. 99 US-HWY Kemp, Texas USA INSTALLATION, OPERATION & MAINTENANCE DATA SHEET For EPL-AEC Series Threaded Enclosures. For use in Class I, Groups B, C & D, Class II, Groups E, F &

More information

LED LIGHTING OPTIONS FOR HAZARDOUS LOCATIONS MARCH 30, 2017

LED LIGHTING OPTIONS FOR HAZARDOUS LOCATIONS MARCH 30, 2017 LED LIGHTING OPTIONS FOR HAZARDOUS LOCATIONS MARCH 30, 2017 HAZARDOUS LOCATION BACKGROUND Q: What constitutes a hazardous location? A: The manager of the facility, in conjunction with local authorities

More information

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL SPECIFICATION FOR APPROVAL CUSTOMER. MODEL NO. BPHE010C701-50 PART NO. LKBPHE010C701-P1-01 MODEL NAME. 10W 15V 700mA LED Driver DATE. 2010/01/15 APPROVED SIGNATURES (Taiwan Headquarter) 5F,NO.127, Lane

More information

50 Watt Low Bay LED Light Fixture - Outdoor Rated - IP67-4,333 Lumens

50 Watt Low Bay LED Light Fixture - Outdoor Rated - IP67-4,333 Lumens 50 Watt Low Bay LED Light Fixture - Outdoor Rated - IP67-4,333 Lumens Part #: GAU-HB-50LED-RT Page: 1 The Larson Electronics GAU-HB-50LED-RT Low Bay light fixture provides operators with a powerful and

More information

OptoLum MegaLine RGBW Luminaire

OptoLum MegaLine RGBW Luminaire OptoLum MegaLine RGBW Luminaire Getting Started OptoLum MegaLine RGBW Luminaires offer indoor cove lighting and wall washing in a compact linear form. This guide contains important information on planning,

More information

Listing Constructional Data Report (CDR)

Listing Constructional Data Report (CDR) Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number 171201095SHA-001 Original UL 1450 Issued: 2010/05/05 Ed: 4 Rev: 2013/11/01 Motor-Operated Air Compressors, Vacuum Pumps,

More information

90 Watt Traditional LED Wall Pack - Replaces 400 Watt Metal Halide Fixtures - IP65

90 Watt Traditional LED Wall Pack - Replaces 400 Watt Metal Halide Fixtures - IP65 90 Watt Traditional LED Wall Pack - Replaces 400 Watt Metal Halide Fixtures - IP65 Part #: LEDHWP-900 The LEDHWP-900 Traditional Style LED Wall Pack Light offers high light output from a compact form factor

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin February 2019 Page 1 of 7 2018 CANADIAN ELECTRICAL CODE SUBJECT: Section 2 General rules Administrative The Safety Codes Act and associated regulations, supplemented

More information

3 WALL ASYMMETRIC W W W. L U M E N W E R X. C O M

3 WALL ASYMMETRIC W W W. L U M E N W E R X. C O M DESCRIPTION PROJECT: Via Wet offers architectural lighting for wet locations in both exterior and interior applications. With a simple TYPE: ¾" high by 4½" wide profile of NOTES: extruded aluminum, Via

More information

PROYECTOR KOKOH UNE EN IK10 IP66

PROYECTOR KOKOH UNE EN IK10 IP66 PROYECTOR KOKOH UNE EN 60598 IK10 IP66 THE DATA SHOWN IN THIS DATA SHEET MAY BE SUBJECT TO CHANGES ACCORDING TO TREND TECHLOGY OUR ENGINEERING DEPARTMENT AND R & D + I UNE EN 60598 A C B IP66 IK10 Height

More information

SPORTSBEAMS 1500 LED USER MANUAL SPORTSBEAMS LIGHTING, INC. v.1.0

SPORTSBEAMS 1500 LED USER MANUAL SPORTSBEAMS LIGHTING, INC. v.1.0 SPORTSBEAMS 1500 LED USER MANUAL v.1.0 SPORTSBEAMS LIGHTING, INC. 1.888.905.6680 WWW.SPORTSBEAMS.COM TABLE OF CONTENTS INTRODUCTION...1 SAFETY WARNINGS...2 POWER SUPPLY Wiring Diagram....3 Fuse Ratings....3

More information

Tuffy II Liquid Level Controls with Electric Switches

Tuffy II Liquid Level Controls with Electric Switches Tuffy II Liquid Level Controls with Electric Switches D E S C R I P T I O N The Tuffy II Liquid Level Switches are float-actuated devices designed for horizontal mounting in a tank or vessel through threaded

More information

SECTION to 5000 AMPERE PLUG-IN AND FEEDER BUSWAYS - SPECTRA. A. Low-Voltage Plug-in Busway to 5000 ampere, 600 VAC

SECTION to 5000 AMPERE PLUG-IN AND FEEDER BUSWAYS - SPECTRA. A. Low-Voltage Plug-in Busway to 5000 ampere, 600 VAC PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Low-Voltage Plug-in Busway - 225 to 5000 ampere, 600 VAC 1.02 RELATED

More information

Feb12 Rev D

Feb12 Rev D Product Specification AMPSEAL* Connectors 108-1329 01Feb12 Rev D 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for AMPSEAL* connectors. 1.2. Qualification

More information

Nov04 Rev B EC

Nov04 Rev B EC Product Specification Mini-Universal MATE-N-LOK* Connector 108-1542 10Nov04 Rev B EC 0990-1499-04 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for MATE-N-LOK*

More information

CONSTRUCTION STANDARDS SECTION CS 15 STREET LIGHTING

CONSTRUCTION STANDARDS SECTION CS 15 STREET LIGHTING CONSTRUCTION STANDARDS SECTION CS 15 STREET LIGHTING CS 15-0l SCOPE: Street Lighting improvements shall be constructed in conformance with Section 86, Signals, Lighting and Electrical Systems, of the CALTRANS

More information

50 Watt Low Profile LED Canopy Light V AC - Motion Sensor - IP65 Rated

50 Watt Low Profile LED Canopy Light V AC - Motion Sensor - IP65 Rated 50 Watt Low Profile LED Canopy Light - 120-277V AC - Motion Sensor - IP65 Rated Part #: LEDCPL-LP-500-MS-WCM The LEDCPL-LP-500-MS-WCM Low Profile LED Quick Mount Canopy Light offers high light output from

More information

MATERIAL SPECIFICATION FOR UNINTERRUPTIBLE POWER SUPPLY SYSTEMS FOR LED TRAFFIC SIGNALS

MATERIAL SPECIFICATION FOR UNINTERRUPTIBLE POWER SUPPLY SYSTEMS FOR LED TRAFFIC SIGNALS ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS.PROV 2475 April 2017 MATERIAL SPECIFICATION FOR UNINTERRUPTIBLE POWER SUPPLY SYSTEMS FOR LED TRAFFIC SIGNALS TABLE OF CONTENTS 2475.01 SCOPE 2475.02

More information

MANUFACTURER'S RESPONSIBILITIES AND REQUIREMENTS FOR FACTORY TESTS

MANUFACTURER'S RESPONSIBILITIES AND REQUIREMENTS FOR FACTORY TESTS MANUFACTURER'S RESPONSIBILITIES AND REQUIREMENTS FOR FACTORY TESTS 1.0 MANUFACTURER'S RESPONSIBILITIES: The manufacturer's responsibilities include, but are not limited to: 1.1 Control of UL Mark - Restrict

More information

WARNING: Risk of fire or electric shock. Do not alter, relocate, or remove wiring, lampholders, power supply or any other electrical component.

WARNING: Risk of fire or electric shock. Do not alter, relocate, or remove wiring, lampholders, power supply or any other electrical component. WARNING! RISK OF FIRE OR ELECTRICAL SHOCK Disconnect power before installing or servicing. WARNING: Risk of fire or electrical shock. Luminaire wiring, power supply, or other electrical parts may be damaged

More information

Mar11 Rev D

Mar11 Rev D Product Specification 108-1836 11Mar11 Rev D 3 mm Micro MATE-N-LOK* Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the 3 mm Micro MATE-N- LOK*

More information

SECTION AUTOMATIC TRANSFER SWITCH

SECTION AUTOMATIC TRANSFER SWITCH SECTION 26 36 23 AUTOMATIC TRANSFER SWITCH PART 1: GENERAL 1.01 SCOPE A. Furnish all labor, materials, equipment and appurtenances, install and test electrically operated, automatic transfer switch (ATS)

More information

PD662 LOOP-POWERED METER Instruction Manual

PD662 LOOP-POWERED METER Instruction Manual PD662 LOOP-POWERED METER C US 4-20 ma Input Loop-Powered -1999 to 2999 Display Easy Four-Button Programming NEMA 4X Enclosure Programmable Noise Filter Loop-Powered Backlight Option 1.7 Volt Drop without

More information

SECTION GENERAL ELECTRICAL REQUIREMENTS PART 1- GENERAL

SECTION GENERAL ELECTRICAL REQUIREMENTS PART 1- GENERAL 1.01 DESCRIPTION SECTION 16000 GENERAL ELECTRICAL REQUIREMENTS PART 1- GENERAL A. This Section includes the general provisions applicable to electrical work and testing of the completed electrical systems.

More information

Mar11 Rev D

Mar11 Rev D Product Specification 108-1542 11Mar11 Rev D Mini-Universal MATE-N-LOK* Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for MATE-N-LOK* mini-universal

More information

1. The plan needs to show compliance with the 2013 CEC, 2013 CBC and 2013 CRC. [ CBC] RESPONSE:

1. The plan needs to show compliance with the 2013 CEC, 2013 CBC and 2013 CRC. [ CBC] RESPONSE: Solar Panels Interactive PV system checklist: 1. The plan needs to show compliance with the 2013 CEC, 2013 CBC and 2013 CRC. [ 107.2 CBC] 2. The electrical plans show a different number of panels than

More information

A. Section includes busway and fittings including plug-in units.

A. Section includes busway and fittings including plug-in units. SECTION 26 25 00 ENCLOSED BUS ASSEMBLIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes busway and fittings including plug-in units. 1.2 REFERENCES A. Institute of Electrical and Electronics Engineers:

More information

INFORMATION BULLETIN

INFORMATION BULLETIN APPROVAL OF MANUFACTURED HOMES & FACTORY-BUILT STRUCTURES (RELOCATABLE AND NON-RELOCATABLE) The following bulletin provides guidance on the application Electrical Safety Regulation, Section 21. This information

More information

Class I Division 1 & 2 Explosion Proof 150 Watt High Bay LED Light Fixture 16,000 Lumens- Pendant

Class I Division 1 & 2 Explosion Proof 150 Watt High Bay LED Light Fixture 16,000 Lumens- Pendant Class I Division 1 & 2 Explosion Proof 150 Watt High Bay LED Light Fixture 16,000 Lumens- Pendant Part #: HBLP-1MLED-PND Page: 1 The Larson Electronics HBLP-1MLED-PND High Bay light fixture provides operators

More information

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8 and 1/4 NPT. Features. Construction. Electrical ANSI Accredited Program PRODUCT CERTIFICATION 4 Direct Acting Subminiature Solenoid Valves /8" and /4" NPT / 856 -WAY Features -way normally closed operation Compact design Brass and 6 stainless steel

More information

Listing Constructional Data Report (CDR)

Listing Constructional Data Report (CDR) Listing Constructional Data Report (CDR) 1.0 Reference and Report Number 103146604PRT-001 Original Standard For Exhaust Hoods For Commercial Cooking Equipment [UL 710:2012 Ed.6+R:22Mar2017] Standard(s)

More information

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications Technical Datasheet Pressure Switch Models: CS2 & CS4 Key Features Compact and rugged design. Stainless steel weatherproof enclosure IP66 / NEMA 4X Hermetically sealed SPDT or microswitch ATEX / IECEx

More information

Qualification Test Report VAL-U-LOK* Connectors

Qualification Test Report VAL-U-LOK* Connectors Qualification Test Report VAL-U-LOK* Connectors 501-534 09Apr09 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on VAL-U-LOK* Connectors to determine their conformance to the requirements

More information

MATERIAL SPECIFICATION FOR SIGNAL HEADS

MATERIAL SPECIFICATION FOR SIGNAL HEADS ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS.PROV 2461 April 2017 MATERIAL SPECIFICATION FOR SIGNAL HEADS TABLE OF CONTENTS 2461.01 SCOPE 2461.02 REFERENCES 2461.03 DEFINITIONS 2461.04 DESIGN

More information

Truss Mini Pendant PENDANT

Truss Mini Pendant PENDANT Overview Realistic steel mini-truss in aluminum Direct, Indirect or Direct/Indirect light distribution Two piece extruded aluminum housing with integral driver Continuous row mounting, standard Can also

More information

15 15A 20 20A 30 30A 40 40A 60 60A. Load voltage(rated) VAC VAC VDC 24VAC VAC

15 15A 20 20A 30 30A 40 40A 60 60A. Load voltage(rated) VAC VAC VDC 24VAC VAC Single phase, Intergrated heatsink type SSR Features Superior di strength : 4,000VAC Improved reliability by maximizing heat protection efficiency with heatsink integrated design and ceramic board Various

More information

MAY-16 REV B2

MAY-16 REV B2 Product Specification 108-20025 06-MAY-16 REV B2 The product described in this document has not been fully tested to ensure conformance to the requirements outlined below. Therefore, TE Connectivity (TE)

More information

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH SPECIFICATIONS FOR LOAD BREAK SWITCH This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE CODES

More information

Electric Sign Energy Certification Service To California Energy Commission Title 24 Technical Requirements and Audit Instructions (ENVS) Lighting

Electric Sign Energy Certification Service To California Energy Commission Title 24 Technical Requirements and Audit Instructions (ENVS) Lighting Electric Sign Energy Certification Service To California Energy Commission Title 24 Technical Requirements and Audit Instructions (ENVS) Lighting Electric Sign Energy Certification Service To California

More information

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2. SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional

More information

D+R INTERNATIONAL LED LIGHTING SPECIFICATION FOR HORTICULTURAL AND AGRICULTURAL APPLICATIONS

D+R INTERNATIONAL LED LIGHTING SPECIFICATION FOR HORTICULTURAL AND AGRICULTURAL APPLICATIONS D+R INTERNATIONAL LED LIGHTING SPECIFICATION FOR HORTICULTURAL AND AGRICULTURAL APPLICATIONS 1. SCOPE This specification covers LED lighting products intended for use in indoor and greenhouse horticultural

More information

SECTION SECONDARY UNIT SUBSTATIONS SECONDARY LESS THAN 1000 V

SECTION SECONDARY UNIT SUBSTATIONS SECONDARY LESS THAN 1000 V SECONDARY UNIT SUBSTATIONS SECONDARY LESS THAN 1000 V PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the secondary unit substation(s) complete from the incoming line terminals

More information

File E Project June 27, 2014 REPORT. Cabinets and Cutout Boxes. BOCCHIOTTI SPA Milano, MI, Italy

File E Project June 27, 2014 REPORT. Cabinets and Cutout Boxes. BOCCHIOTTI SPA Milano, MI, Italy Copyright 2014 UL LLC File E466141 Project 4786190420 June 27, 2014 REPORT On Cabinets and Cutout Boxes BOCCHIOTTI SPA Milano, MI, Italy UL LLC authorizes the above named company to reproduce this Report

More information

W VMV High Wattage Series Champ H.I.D. Luminaires

W VMV High Wattage Series Champ H.I.D. Luminaires 3L 200-400W VMV High Wattage Series 3, 3R, 4, 4X; IP66 Application: VMV high wattage series Champ luminaires are used: in manufacturing plants, refineries, chemical, petrochemical, and other industrial

More information

Mar11 Rev B

Mar11 Rev B Product Specification 108-1674 11Mar11 Rev B Dual Beam Shunt 1. SCOPE 1.1. Content This specification covers the performance, tests and quality requirements for the TE Connectivity (TE) dual beam shunt

More information

electric snow melting mats

electric snow melting mats Mats Product Guide electric snow melting mats Sno*Melter electric mats are designed to be embedded in concrete, asphalt, or under pavers, either as part of a new installation or when repaving. Sno*Melter

More information

City of Ottawa Street Lighting. Streetlight Brackets and Adapters

City of Ottawa Street Lighting. Streetlight Brackets and Adapters TITLE: Engineering Specification RECOMMENDED: S. Edey, NO: 1 REV: APPROVED: D. O Keefe LBS0001 OF REV. DATE: 2010-01-07 6 5 City of Ottawa Street Lighting Streetlight Brackets and Adapters For City of

More information

Random turn-on 15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 2 24VAC VAC

Random turn-on 15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 2 24VAC VAC Single phase, Intergrated heatsink type SSR Features Superior di strength : 4,000VAC Improved reliability by maximizing heat protection efficiency with heatsink integrated design and ceramic board Various