1 MUROX PREFABRICATED BUILDINGS Technical Manual CANADA USA

2 TABLE OF CONTENTS Products, services and solutions....4 General The Murox building system BuildMaster approach... 5 Murox building system General information... 6 System description...6 Drawings and certifications Design criteria General... 7 Load calculations... 7 Foundations Murox building system components Structural steel....8 Fasteners Murox load-bearing wall panel Murox non-bearing wall panel... 8 Roof joists... 8 Finishes....8 Steel deck....9 Options and accessories... 9 Exterior doors... 9 Overhead garage doors Windows... 9 Canopy Fire-resistance rated wall...11 Ventilated thermal panel...11 Mezzanine floor...12 Crane and monorail...12 Fabrication Components Welding Paint Receiving and assembly Installation by Canam Installation by customer...13 Field conditions...14 Installation customer Warranties Technical Data Sheet Standard Murox...15 Technical Data Sheet - Murox CI...17 Architectural details Standard Murox panel Murox CI panel - Continuous Insulation Murox panel for masonry veneer Murox panel for EIFS (Exterior Insulation and Finishing System) BuildMaster, Canam and Murox as well as all logos identifying the activities of Canam Group Inc. and its subsidiaries are trademarks of Canam Group Inc. and its subsidiaries.

3 Products, services and solutions Canam-Buildings ("Canam") specializes in the design and fabrication of steel joists and joist girders, steel deck, purlins and girts and welded wide-flange shapes (WWF), as well as the Murox prefabricated building system, Econox relocatable buildings and Hambro composite floor systems. It offers value-added engineering and drafting services, architectural flexibility and customized solutions and services. What's more, Canam has redefined building design and construction by adopting BuildMaster, a collaborative, safe and quick approach that can reduce installation time of building structures by 15 to 25%. Because product quality, site supervision and deadlines are critical aspects for any project, our reliability makes life easier for our customers. Furthermore, a rigorous site management process has been developed to deliver projects on time. Advanced equipment, well-trained staff and quality products are what sets us apart. Regardless of the project, Canam will meet your needs, while ensuring that current building code requirements are met. Our exceptional service also means just-in-time delivery at a time that works for you. To make sure we eliminate delays, our fleet of trucks delivers your product on time, regardless of your location and schedule. Depending on the region and delivery point, Canam can transport parts in sizes up to 16 ft. (4.9 m) wide by 120 ft. (36.5 m) long. Canam is one of the largest structural steel and steel joists manufacturers in North America. NOTICE Although every effort has been made to ensure that the information and values presented herein are factual and consistent with applicable standards, Canam assumes no responsibility for any errors or oversights that may result from use or interpretation of these data. Anyone using this catalogue assumes all responsibility arising from such use. Please note that due to the constant improvement of our system, the information in this manual may change without notice and should therefore be verified prior to final design of a project. Any comments or suggestions for improving the content of this publication would be highly appreciated and taken into account in future updates. 4

4 General THE MUROX BUILDING SYSTEM The Murox building system is the most effective and rapid design-build solution on the market for the construction of commercial, industrial and institutional buildings. The Murox prefabricated panel system includes prefabricated load-bearing panels, roof and floor joists, steel decking, service doors and windows. All components of the Murox building system are shopdesigned, -fabricated and -assembled, guaranteeing quicker deliveries to work sites. These ideal conditions allow us to maintain strict control over quality, minimizing site supervision and eliminating risks. In addition, depending on their composition, Murox panels can provide a UL-certified one-hour fire rating. Ventilated thermal panels (VTP) are also available to preheat the fresh air used in the building's heating units. The Murox building system also includes: Significant architectural flexibility in the choice of exterior finishes. Elimination of perimeter columns to maximize interior usable space. Minimum lab-tested R-20 thermal resistance. Murox system project management and site supervision during installation. Murox I Typical wall BUILDMASTER APPROACH BuildMaster combines Canam's wealth of experience in the construction industry with the latest in technological advances to achieve unprecedented levels of connectivity, predictability and efficiency. BuildMaster is a completely new way of thinking about building design and construction. The BuildMaster approach is based on a simple principle: if we make the ironworker's job easier, the entire process of building a steel frame building becomes safer, quicker and more collaborative. The BuildMaster goal is simple: make building sites safe and efficient. Through major improvements in industry practices, Canam has reinvented the handling and installation of steel components on-site. Here are a few examples: Grouping of joist types in order of assembly Grouping of tie joists Pre-bolted cross bridging Joist seats bolted onto structural steel Joists and deck identification for easy find Color coding of divisions This approach is now an integral part of Canam's operations and of the Murox building system. 5

5 Murox building system GENERAL INFORMATION The following information describes materials, calculation standards and construction methods used in designing and fabricating a Murox building. They are provided to professionals and contractors to demonstrate all the basic elements used in the Murox building system. Canam reserves the right to change or modify the design or fabrication, or to substitute materials with equivalent or higher-value products than those identified. SYSTEM DESCRIPTION CLEAR-SPAN MUROX BUILDING The clear-span Murox building is made up of exterior wall panels with a shopassembled steel frame that supports at perimeter, joists (roof and floor) and a steel deck. MULTI-SPAN MUROX BUILDING The multi-span Murox building is made up of exterior wall panels with a shopassembled steel frame that supports at perimeter, joists (roof and floor) and steel deck, while interior spans are supported by a system of multi-span columns, beams or joist girders. DRAWINGS AND CERTIFICATIONS Canam supplies assembly plans and details for identifying and connecting all components of the Murox building system included in the contract. Drawings include anchor bolt plan, roof plan and floor plan for mezzanines, cross-sections and elevations, as well as all other details required to ensure quick and efficient assembly. A specific installation manual is also provided with every Murox project. The Murox building is designed according to the customer's requirements as stipulated in the purchase contract. Plans are prepared in compliance with building code requirements applicable in your region and are sealed and approved by an engineer in good standing with a professional association. In addition, Canam's factories meet various quality standards thanks to their numerous certifications. CANADA Calgary, Alberta BCS, SJI Mississauga, Ontario BCS, SJI Saint-Gédéon-de-Beauce, Québec ISO 9001:2008, BCS, SJI, AISC Boucherville, Québec ISO 9001:2008, BCS, ICCA UNITED STATES Jacksonville, Floride AISC, SJI Peru, Illinois SDI Point of Rocks, Maryland AISC, SJI Washington, Missouri AISC, SJI South Plainfield, New Jersey SDI Sunnyside, Washington AISC, SJI, ICC 6

6 Murox building system DESIGN CRITERIA GENERAL All components of the Murox system, including the steel structure, are designed in accordance with Canadian or U.S. building codes, depending on the location, as mentioned in the Canam contract (e.g.: preliminary sketches, customer file, etc.). LOAD CALCULATIONS Loads are calculated in accordance with Canadian or U.S. building codes. FOUNDATIONS Canam supplies foundation reactions at the base of columns, but accepts no responsibility for foundation calculations. The foundation design must be executed by a qualified engineer in accordance with applicable building codes and with design criteria and foundation reactions supplied by Canam. Tolerances The final level and alignment of foundations must be within the maximum deviation tolerances from dimensions on plans. Murox components are designed to allow a certain deviation, but cannot accommodate deviations out of tolerance range. Anchor bolts The Murox components are fabricated to precise dimensions. Consequently, the contractor must make sure that anchor bolts are precisely placed on foundations as indicated on plans supplied by Canam. 7

7 Murox building system MUROX BUILDING SYSTEM COMPONENTS STRUCTURAL STEEL W-sections, angles, rods, channels and other hot-rolled sections are produced to CAN/CSA G W standards. Cold-formed components are structural grade with a limit of elasticity of 50 or 55 kip/in² (345 or 380 MPa). FASTENERS All bolts, nuts and washers used for the main structure, except for anchor rods, are to ASTM A325, Type 1 standard or higher. All anchor rods are A307 standard or higher, as specified in the plans supplied by Canam. MUROX LOAD-BEARING WALL PANEL The steel structure of the Murox wall panel is shop-assembled and designed to withstand the applicable loads. A bracing system incorporated into certain Murox panels, makes it possible to transfer horizontal loads to the foundations. The maximum height of a Murox load-bearing wall panel is 44.5 ft. (13.5 m). For steel cladding, plywood or gypsum installation, the support system is made up of 16-gauge horizontal steel girts. MUROX NON-BEARING WALL PANEL In addition to its regular system, Canam has developed over the years, specialty products that offer the same benefits in terms of design, manufacturing quality and speed of installation. The Murox non-bearing wall is thus an optimal solution for very tall buildings. It provides the same benefits as the Murox wall with a traditional frame design and can be higher than 44.5 ft. (13.5 m). The panels are designed to resist wind loads and to support their own weight. ROOF JOISTS Open-web steel roof joists manufactured by Canam are designed to support all applicable loads. Roof slopes for drainage are provided for the most part by the steel structure. For further information, consult Canam's Joists and Joist Girders catalogue. FINISHES Whether the exterior finish chosen is one offered by Canam or any another finish available on the market, we have the ideal solution for your project. The standard steel wall cladding for Murox buildings is available in a number of profiles and a wide range of colors. It can also be installed vertically and horizontally. For more information, consult Canam's Cladding Products brochure. The shop-installed exterior steel cladding can be selected from the following options: M-156R steel cladding installed vertically or M-2297 installed horizontally or vertically. Other steel claddings can also be shop-installed. Ask your representative for more information. For field installation of exterior finishes, such as masonry, acrylic coating systems (EIFS), wood or other, the Murox panel wall composition can be modified to adapt to different finishes available on the market. Load-bearing wall panel I Structure Load-bearing wall panel I Structure with bracing 8 Load-bearing wall panel I L-shaped structure for large openings

8 Murox building system The shop-installed interior steel cladding can be selected from the following options: M-156R or M-2297 both installed vertically. If an interior gypsum board finish is required, the Murox panels are supplied with an exposed polypropylene vapor barrier on the interior face. As an option, steel furring can also be provided by Canam and installed by the contractor on site. The 20 gauge galvanized steel furring channels are available in 2 in. x 2 in. (50.8 mm x 50.8 mm) and 3 in. x 3 in. (76.2 mm x 76.2 mm) sizes. Plywood panels used as wood blocking intended for attachments can also be shopinstalled. Hexagonal self-tapping and oxidation-resistant steel screws with neoprene washers are used to fasten the steel cladding. The color of the screw head is matched to the steel cladding. STEEL DECK The roof s steel deck manufactured by Canam comes in two profile depths: model P-2404 in 76.2 mm (3 in.), and P-3606 in 38.1 mm (1 ½ in.). Both available in galvanized (Z-275) or satin finish (Light Zinc Coat LZC ZF-075). The gauge of the steel deck is determined by Canam according to applicable loads and spans. For more information, consult Canam Steel Deck catalogue. OPTIONS AND ACCESSORIES EXTERIOR DOORS Shop-installed standard (single or double) exterior doors supplied by Canam are made of premium quality 18 gauge wipe coat galvanized steel with R-12 polyurethane foam insulated core and weather-stripping. The door frames are 16 gauge wipe coat galvanized steel with thermal breaks. Available options: Integrated door glazing, fixed, single pane or sealed unit, tempered or wired glass. Hardware: panic exit bar on the inside and knob on the outside, deadbolt operated by key from the outside. UL/ULC listed fire rated doors are also available. OVERHEAD GARAGE DOORS A garage door opening measuring 9 ft. (2.7 m) wide or less can be provided in a single Murox panel. The garage door frame made up of steel C-channels is also shop-installed. Garage door openings measuring more than 9ft. (2.7 m) are installed within two Murox panels. The garage door frame is made up of steel C-channels and are integrated into the panels. In the case of garage doors with door seals, Canam supplies the structural support for the garage. The garage door including hardware is always supplied and installed by other. WINDOWS Windows supplied by Canam are shop-installed under certain conditions. Extruded aluminum frames measuring 162 mm (6 in.) wide are thermally broken with a PVC thermal break. Screens are provided for sliding or casement windows. Standard colors for the aluminum frame are white and brown, but other finishes such as clear anodized aluminum are available by request. Sealed units are available in a number of options, such as low emissivity glass filled with Argon gas, tinted glass, etc. In addition, if the installation of windows is done on site, the customer can select their own supplier. 9

9 Murox building system CANOPY As a complement to the Murox building, Canam has a number of steel framed, watertight modular canopy systems that are custom-manufactured according to the project. The three models described here are the most common: Canopy with built-in gutter This modular canopy system is finished with a prepainted steel sheet. A polyurethane primer and two coats of urethane acrylic enamel provide lasting durability and is available in a wide range of colors. With its built-in gutter, this modular canopy system is quickly and easily installed. Canopy with sloped roof surface This canopy system is usually finished with the same steel cladding as the building for a seamless integration. Canopy with flat roof surface This canopy is finished with a steel cladding on all faces and comes with Canam's steel deck on the roof. Supply and installation of roofing membranes is under the responsibility of contractor. Canopy with sloped roof surface and integrated gutter Canopy with sloped roof surface Canopy with flat roof surface 10

10 Murox building system FIRE-RESISTANCE RATED WALL The Murox wall panel can also be designed to provide a UL/ULC-certified one-hour fire resistance rating from interior to exterior. The panel is available for loadbearing and non-bearing walls. Two-hour fire resistance rating (not certified) wall construction UL\ULC is available. Test method Fire resistance Assembly number CAN/ULC S101 - Standard Methods of Fire Endurance Tests of Building Construction and Materials 1 hour W011 Murox certified 1-hour fire rating ULC Design - W011 UL Design - U048 VENTILATED THERMAL PANEL The ventilated thermal panel (VTP) makes it possible to capture solar energy to preheat the fresh air used by air makeup units. Up to 25% of the cost to heat fresh air for the building can thus be saved. What's more, the system is simple: negative pressure in the wall's plenum causes air to be drawn through perforations at the base of this chamber. Practically the same thickness as a regular Murox wall, it matches the rest of the building perfectly. Complete shop-assembly of the VTP provides for very quick installation on site. Class Class description Performance factor VERIFICATION OF SOLAR COLLECTOR Solar Collector Checklist CAN/CSA-F Murox I Firewall type of wall Murox I Ventilated thermal panel 11

11 Murox building system MEZZANINE FLOOR The exterior Murox panels supporting the mezzanine floors are reinforced to support floor loads. The mezzanine floor structure consists of steel joists supported by intermediate beams and columns as required. CRANE AND MONORAIL The approach for supporting a crane varies on the type and capacity of crane selected. Canam's technical team will guide you in selecting the best approach suited to your needs. Murox panels offer some benefits for the following types: A monorail generally is suspended from the joists. The joists can then be supported by Murox panels. Canam supplies the beam that also acts as a guide rail for the monorail. A crane with a capacity of 10 Metric tons or less can also be suspended from the steel joists, which are supported by Murox panels. Canam supplies the beam that also acts as a guide rail. This approach lightens the structure, reduces the number of parts to install and simplifies the foundations compared with a conventional frame (Figure 1). A top-running crane with a capacity of more than 10 Metric tons must be supported by a conventional frame, independent of the Murox panels. Canam supplies the beams without the guide rail and attachments (stops, staples, etc.). A seated connection is used for support beam to column connection (Figure 2). Lastly, in the case of a high-capacity crane, a frame independent of building structure may be required. Figure 1 FABRICATION COMPONENTS The panels, beams, columns, steel joists and other secondary components are fabricated in accordance with the engineering drawings, the latest edition of CAN/ CSA-S16 Limit State Design of Steel Structures and AISC standards. WELDING All welded connections conform to the latest editions of CSA W59 and Structural Welding Code AWS D1.1 Steel. Canam manufacturing plant is certified by the Canadian Welding Bureau in accordance with Standard W47.1 Division 1. PAINT One coat of grey primer is applied to structural steel. The primer protects the steel from exposure to an essentially non-corrosive atmosphere for a period of up to six months. Figure 2 12

12 Murox building system RECEIVING AND ASSEMBLY INSTALLATION BY CANAM Murox buildings are generally erected by specialized teams working under the supervision of a Canam site supervisor. Canam thus assumes full responsibility for receiving, offloading and erection of the building in accordance with industry and Canam's standards. Role of Canam's site supervisor Coordinate deliveries. Verify loads and condition of equipment. Ensure that all work is done in accordance with Canam's standards. Coordinate the work according to customer's requirements. INSTALLATION BY CUSTOMER The customer may decide to have the Murox building erected by the erector of his choice. The quality and speed of work performance therefore relies primarily on the erector s abilities and experience. Role of the erector The erector must supply skilled and experienced labor to erect the Murox building in accordance with the plans and instructions provided by Canam. In respect to customary practices, the erector is responsible for performing all work related to receiving and assembling the components provided by Canam. It goes without saying that the erector must have all the tools and equipment necessary to handle, assemble and install the different components. Some minor cutting and adjustments are necessary and are part of the erector s scope of work. The customer is responsible for any damage caused by negligence from the erector. Receiving and inventory All parts of a Murox building are carefully packaged and inspected to prevent damage during delivery. The transportation company is responsible for delivering the components in perfect condition. The customer must verify the quantities and condition of materials delivered. The customer is responsible for signifying any material damage or defect on the delivery slips and taking immediate arrangements for replacement with a Canam representative, if necessary. No claim will be accepted by Canam unless those procedures have been followed. 13

13 Murox building system Storage and protection of materials Where materials are stored on site, care must be taken to ensure that the ends are raised from the ground to allow water to circulate. The contractor is responsible for ensuring additional protection from weather. Once the erector has unpacked the boxes, packages and other material, he is responsible for ensuring that these are protected from damage from all weather conditions. FIELD CONDITIONS Work areas The general contractor or buyer must provide and maintain the work and storage areas, keep vehicular access clear and ensure an adequate load bearing capacity at all times for circulation of vehicles and equipment, as well as storage of materials. The general contractor or buyer must also remove snow from access roads and traffic areas during winter. Furthermore, the general contractor or customer assumes full responsibility for breakdowns or delays as a result of poor site conditions and agrees to pay any associated costs. The above-mentioned work and storage areas consist of the entire building area, plus a zone extending at least 30 ft. (9 m) outside building perimeter. Aerial and land obstacles The general contractor or customer must have any aerial or land obstacle, that could hinder assembly of the structure, moved or relocated at his expense (trees, power lines, etc.). He must also take the necessary steps to protect, remove or de-energize electrical distribution lines and obtain all mandatory permits. The general contractor assumes full responsibility for any delays resulting from failure to take such steps and perform all related work and agrees to pay any associated costs. INSTALLATION DETAILS For installation details regarding the Murox building, refer to the Murox Installation Manual produced on a custom basis for each building. WARRANTIES Having been used all across North America in extreme weather conditions, the panels of the Murox building system have proven themselves. The materials and, where applicable, installation work are guaranteed against defects of labor and materials for a period of one year from completion of Canam's work. As for the components that are not fabricated by Canam, manufacturer's warranties apply. 14

14 Technical Data Sheet - Murox Standard Panel PREFABRICATED PANELS MUROX STANDARD WALL DESCRIPTION Prefabricated load-bearing wall panel finished with interior and exterior steel cladding finishes over a structural cavity insulated steel structure core. The structural columns inside the panel consist of steel channels up to 12 in. (30.5 cm) wide. The weather and vapor barriers are shop-installed and a continuous seal between panels is completed on-site. The effective thermal resistance of the wall is R-20. Installation can be done in all four seasons. Components Exterior finish steel cladding M-156R or M-2297 (see technical data sheet for Murox Cladding Products). For the various exterior cladding options, see the cladding finishes section of the Technical Manual. Air barrier, non-woven type 1, air penetration resistance: <0.004 pcm/sq. ft.@1.57 psf (0.01 L/s/m² at 75 Pa). Structural steel framed panels. Glass fiber blanket insulation of 6 in. (15.2 cm), R-20 thermal resistance, shop-installed in panel cavity. Vapor barrier, polypropylene type 1, permeability: 1.15 ng/pa s m² (0.02 perm). Interior finish steel cladding M-156R or M-2297 (see technical data sheet for Murox Cladding Products). For the various interior cladding options, see the cladding finishes section of the Technical Manual. Versatile use Industrial, commercial and institutional applications. New construction. Building extensions. Buildings where combustible construction is authorized. Buildings where non-combustible construction is required. Restrictions For buildings with certain specific usage, such as pools or arenas, we recommend using a Murox CI building envelope. Buildings requiring a Fire-Resistance Rating (FRR). An optional panel with a FRR of one hour is available. Refrigerated buildings. Agri-food buildings with food safety standards. Contact your Canam representative for any question regarding restrictions and options available for your project. 15

15 Technical Data Sheet - Murox Standard Panel Technical data Standard test methods: ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen ASTM C1363 Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements Table of Physical Characteristics Characteristic Test method Result Effective thermal resistance ASTM C1363 R (h- F-sq. ft.)/btu Air permeability ASTM E283 < 0,05 l/s-m² at 75 Pa Sound transmission coefficient ASTM E90 39 Product data Average weight Length, width and height Column sizes Transportation 7 lb (3.2 kg) per sq. ft. From 2 to 10 ft. (0.6 to 3 m) wide and maximum 44 ft. 6 in. (13.6 m) high 6 to 12 in. (152.4 to mm) Delivery by standard truck Contribution to LEED certification The Murox Standard prefabricated wall panel can contribute in obtaining the following LEED credits: EA (Energy and Atmosphere) Credit 1 for optimization of new or existing building energy performance MR (Materials and Resources) Credits 4.1 and 4.2 for content of recycled materials MR (Materials and Resources) Credits 5.1 and 5.2 for materials of local or regional origin All Murox panels are manufactured at our plant in Saint-Gédéon-de-Beauce, Quebec. For further information, contact your Canam representative. Installation Erector qualification: Only a steel building erector with extensive experience in assembling and similar work in regards to the products, design and scale of the work specified for the Murox system should be used. The erector must meet all requirements and standards for quality and installation set by Canam. Quality control The Saint-Gédéon-de-Beauce plant is ISO 9001:2000, CWB, SJI, AISC and CISC certified. A strict manufacturing quality control procedure is implemented in our plants, ensuring quality and consistency of the product through several points of strategic control. For buildings erected by Canam, a certificate of compliance is issued upon completion of building assembly. 16 PRODUCT INFORMATION Conforms to classification in MasterFormat TM published by CSC and CSI. The correspondent number and title are Fabricated Engineered Structures-Steel Building System. Go to canam-construction.com for product information updates

16 Technical Data Sheet - Murox CI Panel PREFABRICATED PANELS MUROX CI WALL DESCRIPTION Prefabricated load-bearing wall panel finished with interior and exterior steel cladding finishes over a structural cavity insulated steel structure core, in addition to continuous exterior insulation R-10. The structural columns inside the panel consist of steel channels up to 12 in. (30.5 cm) wide. The weather and vapor barriers are shop-installed and a continuous seal between panels is completed on-site. The effective thermal resistance of the wall is R-21. Installation can be done in all four seasons. Components Exterior finish steel cladding M-156R or M-2297 (see technical data sheet for Murox Cladding Products). For the various exterior cladding options, see the cladding finishes section of the Technical Manual. Air barrier, non-woven type 1, air penetration resistance: <0.004 pcm/sq. psf (0.001 L/s/m² at 75 Pa). Extruded polystyrene rigid insulation 2 in. (5 cm) with R-10 thermal resistance completely covering the outside of the panel frame. Structural steel framed panels. Glass fiber blanket insulation of 6 in. (15.2 cm), R-20 thermal resistance, shop-installed in panel cavity. Vapor barrier, polypropylene type 1, permeability: 1.15 ng/pa s m² (0.02 perm). Interior finish steel cladding M-156R or M-2297 (see technical data sheet for Murox Cladding Products). For the various interior cladding options, see the cladding finishes section of in the Technical Manual. Versatile use Industrial, commercial and institutional applications. New construction. Building extensions. Buildings where combustible construction is authorized. Buildings where non-combustible construction is required. Restrictions Buildings requiring a Fire-Resistance Rating (FRR). An optional panel with a FRR of one hour is available. Refrigerated buildings. Agri-food buildings with food safety standards. Contact your Canam representative for any question regarding restrictions and options available for your project. 17

17 Technical Data Sheet - Murox CI Panel Technical data Standard test methods: ASTM C1363 Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements CAN/ULC S742 Standard for Air Barrier Materials Meets industry criterias to be considered a pressure-equalized rainscreen wall with continuous insulation Table of Physical Characteristics Characteristics Test method Result Effective thermal resistance ASTM C1363 Minimum R-21.3 (h- F-sq. ft.)/btu Air permeability CAN\ULC S742 Classed A1 (S650/H20) Sound transmission coefficient ASTM E90 38 Product data Average weight Length, width and height Column sizes Transportation 7 lb (3,2 kg) per sq. ft. From 2 to 10 ft. (0.6 to 3 m) wide and 44 ft. 6 in. (13.6 m) high 6 to 12 in. (152.4 to mm) Delivery by standard truck Contribution to LEED certification The Murox Standard prefabricated wall panel can contribute to obtaining the following LEED credits: EA (Energy and Atmosphere) Credit 1 for optimization of new or existing building energy performance MR (Materials and Resources) Credits 4.1 and 4.2 for content of recycled materials MR (Materials and Resources) Credits 5.1 and 5.2 for materials of local or regional origin All Murox panels are manufactured at our plant in Saint-Gédéon-de-Beauce, Quebec. For further information, contact your Canam representative. Installation Erector qualification: Only a steel building erector with extensive experience in assembling and similar work in regards to the products, design and scale of the work specified for the Murox system should be used. The erector must meet all requirements and standards for quality and installation set by Canam. Quality control The Saint-Gédéon-de-Beauce plant is ISO 9001:2000, CWB, SJI, AISC and CISC certified. A strict manufacturing quality control procedure is implemented in our plants, ensuring quality and consistency of the product through several points of strategic control. For buildings erected by Canam, a certificate of compliance is issued upon completion of building assembly. 18 PRODUCT INFORMATION Conforms to classification in MasterFormat TM published by CSC and CSI. The correspondent number and title selected are Fabricated Engineered Structures-Steel Building System. Go to canam-construction.com for product information updates

18 19

19 Architectural details - Standard Murox panel Typical wall section 20

20 Architectural details - Standard Murox panel Girt Anchor at foundation 21

21 Architectural details - Standard Murox panel Junction at wall/mezzanine floor 22

22 Architectural details - Standard Murox panel Junction at wall/roof - Standard parapet 23

23 Architectural details - Standard Murox panel Junction at wall/roof Steel stud parapet 24

24 Architectural details - Standard Murox panel Junction at wall/roof - Inegrated parapet 25

25 Architectural details - Standard Murox panel Junction at wall/roof Roof edge termination 26

26 Architectural details - Standard Murox panel Junction at wall/roof - Roof overhang 27

27 Architectural details - Standard Murox panel Panel joint and exterior Corner finishing 28

28 Architectural details - Standard Murox panel Exemple of exterior elevation 29

29 Architectural details - Standard Murox panel Overhead garage door 30

30 Architectural details - Standard Murox panel Section - Overhead garage door 31

31 Architectural details - Standard Murox panel Exterior door 32

32 Architectural details - Standard Murox panel Section - Exterior door 33

33 Architectural details - Standard Murox panel Window 34

34 Architectural details - Standard Murox panel Section - Window 35

35 Architectural details - Murox CI panel Wall section - continuous insulation 36

36 Architectural details - Murox CI panel Girt Anchor at foundation 37

37 Architectural details - Murox CI panel Junction at wall/mezzanine floor 38

38 Architectural details - Murox CI panel Junction at wall/roof - Standard parapet 39

39 Architectural details - Murox CI panel Junction at wall/roof Steel stud parapet 40

40 Architectural details - Murox CI panel Junction at wall/roof Panel integrated parapet 41

41 Architectural details - Murox CI panel Junction at wall/roof Roof edge termination 42

42 Architectural details - Murox CI panel Junction at wall/roof - Roof overhang 43

43 Architectural details - Murox CI panel Panel joint and exterior corner finishing 44

44 Architectural details - Murox CI panel Example of exterior elevation 45

45 Architectural details - Murox CI panel Overhead garage door 46

46 Architectural details - Murox CI panel Section - Overhead garage door 47

47 Architectural details - Murox CI panel Exterior door 48

48 Architectural details - Murox CI panel Section - Exterior door 49

49 Architectural details - Murox CI panel Window 50

50 Architectural details - Murox CI panel Section - Window 51

51 Architectural details - Murox panel for masonry veneer Typical wall section Masonry veneer system 52

52 Architectural details - Murox panel for masonry veneer Girt Anchor at foundation 53

53 Architectural details - Murox panel for masonry veneer Junction at wall/mezzanine floor 54

54 Architectural details - Murox panel for masonry veneer Junction at wall/roof Steel stud parapet 55

55 Architectural details - Murox panel for masonry veneer Junction at wall/roof Panel integrated parapet 56

56 Architectural details - Murox panel for masonry veneer Junction at wall/roof - Roof edge termination 57

57 Architectural details - Murox panel for masonry veneer Panel joint and exterior corner finishing 58

58 Architectural details - Murox panel for masonry veneer Example of exterior elevation 59

59 Architectural details - Murox panel for masonry veneer Exterior door 60

60 Architectural details - Murox panel for masonry veneer Section - Exterior door 61

61 Architectural details - Murox panel for masonry veneer Window 62

62 Architectural details - Murox panel for masonry veneer Section - Window 63

63 Architectural details - Murox panel for EIFS Wall section 64

64 Architectural details - Murox panel for EIFS Girt Anchor at foundation 65

65 Architectural details - Murox panel for EIFS Junction at wall/mezzanine floor 66

66 Architectural details - Murox panel for EIFS Junction at wall/roof - Steel stud parapet 67

67 Architectural details - Murox panel for EIFS Junction at wall/roof Panel integrated parapet 68

68 Architectural details - Murox panel for EIFS Junction at wall/roof - Roof edge termination 69

69 Architectural details - Murox panel for EIFS Junction at wall/roof - roof overhang 70

70 Architectural details - Murox panel for EIFS Panel joint and exterior corner finishing 71

71 Architectural details - Murox panel for EIFS Example of exterior elevation 72

72 Architectural details - Murox panel for EIFS Overhead garage door 73

73 Architectural details - Murox panel for EIFS Section - Overhead garage door 74

74 Architectural details - Murox panel for EIFS Exterior door 75

75 Architectural details - Murox panel for EIFS Section - Exterior door 76

76 Architectural details - Murox panel for EIFS Plan detail - Window 77

77 Architectural details - Murox panel for EIFS Section - Window 78

78 canam-construction.com Canam Group Inc., Last modified on 07/2016 Printed in Canada

BEARING METAL STUD FRAMING

BEARING METAL STUD FRAMING L-1 Section 05410 Long Form Specification LOAD BEARING METAL STUD FRAMING This section includes axially loaded steel studs, with unique slotted top channels, usually of 0.91, 1.2 and 1.5 mm (16, 18, or

More information

HAMBRO COMPOSITE FLOOR SYSTEM

HAMBRO COMPOSITE FLOOR SYSTEM HAMBRO COMPOSITE FLOOR SYSTEM OUR EXPERTISE AT YOUR SERVICE Canam has been offering owners, real estate developers, architects, engineers and contractors an array of construction solutions since 1970.

More information

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6 DECEMBER, 2016 Page 1 of 6 1 GENERAL 1.01 RELATED SECTIONS.1 Section 01 33 00 - Submittal Procedures..2 Section 07 21 16 - Batt and Blanket Insulation..3 Section 07 92 10 - Sealants..4 Section 09 91 00

More information

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011. DIVISION 05 METALS 05 12 00 STRUCTURAL STEEL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural steel framing members, support members. 1.2 RELATED REQUIREMENTS A. Section 05 50 00 - Metal Fabrications:

More information

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK DIVISION 5 - STRUCTURAL STEEL AND IRON WORK SECTION 05100 STRUCTURAL METAL FRAMING PART 1.00 GENERAL 1.01 SCOPE OF WORK A. Work Included: 1. 2. Structural steel complete in place. Steel joists complete

More information

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) Manual of Steel Construction. SECTION 07 42 63 FABRICATED WALL PANEL ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Provide ACCEL-E steel thermal-efficient-panel wall system. 1.2 RELATED SECTIONS A. Section 05 40 00 - Cold Formed

More information

SECTION STAINLESS STEEL WALL PANELS

SECTION STAINLESS STEEL WALL PANELS SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.

More information

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing. PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 13 34 00 FABRICATED ENGINEERED STRUCTURES A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1

More information

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural cantilever rack design. In addition, it is

More information

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns. PAGE 051200-1 SECTION 051200 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,

More information

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 Part 1 General 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified,

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 22 16 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. SECTION 08625 METAL FRAMED SKYLIGHT PART 1 GENERAL 1.01 SECTION INCLUDES: A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. B. Fabrication

More information

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 07 4243 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below.

More information

SECTION NON--STRUCTURAL METAL FRAMING

SECTION NON--STRUCTURAL METAL FRAMING The Collective Voice of America s Steel Framing Industry The Steel Framing Industry Association (SFIA) is dedicated to expanding the market for cold-formed steel in construction through programs and initiatives

More information

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this

More information

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society

More information

SPECIFICATION SECTION : GLASS FLOORING & FRAMING GPX FireFloor System (Patented)

SPECIFICATION SECTION : GLASS FLOORING & FRAMING GPX FireFloor System (Patented) Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information

SECTION METAL BUILDING SYSTEMS

SECTION METAL BUILDING SYSTEMS SECTION 13 3419 PART 1 GENERAL 1.01 SECTION INCLUDES A. Manufacturer-engineered, shop-fabricated structural steel building frame. B. Insulated Metal wall and roof panels including gutters and downspouts.

More information

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II SECTION 052100 - STEEL JOISTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections

More information

WALLTITE ECO Air Barrier System. Welcome

WALLTITE ECO Air Barrier System. Welcome WALLTITE ECO Air Barrier System Welcome Program WALLTITE ECO air barrier system Assembly and installation Evaluation and compliance Program and support 2 Design System components sealant WALLTITE ECO spray

More information

HOTEL SPECIFICATION SECTION 08100

HOTEL SPECIFICATION SECTION 08100 Part 1 General HOTEL SPECIFICATION SECTION 08100 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified including, but not limited

More information

1.02 SYSTEM DESCRIPTION

1.02 SYSTEM DESCRIPTION 1 OF 7 MODULAR MEZZANINES GUIDE SPECIFICATIONS FOR PART 1 - GENERAL 1.01 RELATED WORK A. SECTION 03 30 00: Cast in Place Concrete (and Concrete Finishing) 1. The area where mezzanine is installed shall

More information

HAMBRO COMPOSITE FLOOR SYSTEM

HAMBRO COMPOSITE FLOOR SYSTEM HAMBRO COMPOSITE FLOOR SYSTEM OUR EXPERTISE AT YOUR SERVICE Canam has been offering owners, real estate developers, architects, engineers and contractors an array of construction solutions since 1970.

More information

SECTION COLD-FORMED METAL FRAMING

SECTION COLD-FORMED METAL FRAMING SECTION 05.40.00 COLD-FORMED METAL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Cold-formed metal framing for: B. Exterior load-bearing steel stud walls. 1. Interior load-bearing steel stud walls. 2.

More information

SECTION COLD-FORMED METAL FRAMING

SECTION COLD-FORMED METAL FRAMING SECTION 05.40.00 COLD-FORMED METAL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Cold-formed metal framing for: B. Exterior load-bearing steel stud walls. 1. Interior load-bearing steel stud walls. 2.

More information

Building Your Visions

Building Your Visions Ferguson C EAP Curtain Wall Systems Ferguson-EAP 130HP Series High Performance Curtain Wall System Ferguson s 130HP curtain wall system was developed for high performance double, triple, unique acoustical

More information

[Project Name] Section [ ]

[Project Name] Section [ ] Page 1 PART 1 - GENERAL 1.1 SECTION INCLUDES 1.1.1 Design, labor, products, equipment and services necessary for interior/exterior Aluminum Facade System (AFS) work, in accordance with the Contract Documents.

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION METAL WALL PANEL SYSTEM

SECTION METAL WALL PANEL SYSTEM CSI Format for Metal Wall Panel System Specification SECTION 07410 METAL WALL PANEL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior Metal Plate Wall Panels B. Substructure and Framing C. Structural

More information

SECTION PRE-ENGINEERED EXTRUDED ALUMINUM DECKING WALKWAY COVERS SPECIFICATION

SECTION PRE-ENGINEERED EXTRUDED ALUMINUM DECKING WALKWAY COVERS SPECIFICATION Awning Works Inc Aluminum Decking Walkway Cover Specification CSI- Division 10 SECTION 10530 PRE-ENGINEERED EXTRUDED ALUMINUM DECKING WALKWAY COVERS SPECIFICATION PART 1 GENERAL 1.01 DESCRIPTION OF WORK

More information

STATEMENT OF SPECIAL INSPECTION FORM

STATEMENT OF SPECIAL INSPECTION FORM Project Title: Permit #: Project Address: STATEMENT OF SPECIAL INSPECTION FORM This Statement of Special Inspections is submitted in fulfillment of the requirements of CBC Sections 1704 and 1705. Special

More information

ENVIROBEAM SECTION ENVIRO-ROOF CURBS

ENVIROBEAM SECTION ENVIRO-ROOF CURBS SECTION 077213 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Manufactured, structurally engineered, thermally-insulated, thermally-broken, cold-formed patented roof curbs, all of which can be insulated

More information

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS SECTION 08620 UNIT SKYLIGHTS PART 1 GENERAL 1.01 SECTION INCLUDES A. Performance and product component information for VELUX QPF selfflashed fixed skylight. B. Unit skylight mounted directly to roof decking.

More information

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

AND ACCESSORIES FOR DRYWALL CONSTRUCTION STEEL TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION Quality in your corner. THE STRENGTH WITHIN MONTREAL TORONTO CALGARY EDMONTON VANCOUVER STEEL TRIMS AND ACCESSORIES for Construction BAILEY HAS YOUR

More information

Polycrete Big Block Standard Specification

Polycrete Big Block Standard Specification Polycrete Big Block Standard Specification SECTION 03 11 19 INSULATED CONCRETE FORMING 10/13 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent

More information

MASTER GUIDE SPECIFICATION

MASTER GUIDE SPECIFICATION COMPOSITE TOTALJOIST (CTJ) GUIDE NOTE: This master specification section includes COMPOSITE TOTAL JOIST GUIDE NOTES identified as CTJ GUIDE NOTE for information purposes and to assist the specification

More information

SECTION COLD-FORMED METAL TRUSSES

SECTION COLD-FORMED METAL TRUSSES SECTION 054400 COLD-FORMED METAL TRUSSES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2006/08/01 Section 05121 Structural Steel for Buildings Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3 Section

More information

.2 Section Metal Fabrications: Steel channel frame to suit metal door and operator.

.2 Section Metal Fabrications: Steel channel frame to suit metal door and operator. Page 1 This section includes AMBICO Acoustic Steel Sliding Door assemblies which includes electric operators as an integral part of the assembly. This section includes proprietary, descriptive and performance

More information

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS SECTION 08 4113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Aluminum entrance doors and frames. 2. Glass infill panels. 3. Door hardware. B. Related Sections:

More information

Guide for Inspecting Metal Building Systems. First Edition

Guide for Inspecting Metal Building Systems. First Edition Guide for Inspecting Metal Building Systems First Edition 1 st Edition Guide for Inspecting Metal Building Systems 1300 Sumner Avenue Cleveland, Ohio 44115 Copyright 2016 Metal Building Manufacturers Association,

More information

DIAPHRAGM ACTION AT THE ROOF LEVEL: USE OF STEEL DECK IN LATERAL LOAD RESISTING SYSTEM AND THE ROLE OF DIAPHRAGM. By Pierre Gignac, P.Eng.

DIAPHRAGM ACTION AT THE ROOF LEVEL: USE OF STEEL DECK IN LATERAL LOAD RESISTING SYSTEM AND THE ROLE OF DIAPHRAGM. By Pierre Gignac, P.Eng. DIAPHRAGM ACTION AT THE ROOF LEVEL: USE OF STEEL DECK IN LATERAL LOAD RESISTING SYSTEM AND THE ROLE OF DIAPHRAGM By Pierre Gignac, P.Eng. June 2010 1 TABLE OF CONTENTS Diaphragm action at the roof level

More information

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS VELUX SECTION 08 62 00 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Dynamic dome unit skylight with formed curb counterflashing for mounting on site-built or prefabricated roof curbs, for flat, low-slope and

More information

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications.

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications. SECTION 09.22.16 NON-LOAD BEARING WALL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Non-load bearing metal studs for wall assemblies. B. Area Separation and shaft wall framing products. 1.2 RELATED SECTIONS

More information

Corium Brick Rainscreen System Specifications

Corium Brick Rainscreen System Specifications CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated

More information

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1 GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials and services to furnish and install SECURITY

More information

Gold Bond BRAND Gypsum Sheathing

Gold Bond BRAND Gypsum Sheathing BRAND 09 06 29 16 00/NGC 43/NGC brand is a moisture-resistant sheathing installed on the outside of exterior framing as a substrate for exterior claddings. It is manufactured with a treated water-resistant

More information

AMBICO Limited Section and ACOUSTIC STEEL DOOR AND FRAME ASSEMBLIES Page 1

AMBICO Limited Section and ACOUSTIC STEEL DOOR AND FRAME ASSEMBLIES Page 1 Page 1 This section includes AMBICO Acoustic Steel Doors and Frames as well as perimeter and bottom acoustic seals, and glazing if required all of which can be fire rated or non-rated. The aforementioned

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS PART 1 - GENERAL 1.01 SUMMARY A. Section includes: 1. Storefront systems and aluminum framed glass doors. 2. Hardware, fasteners, accessories, filler pieces, etc., required

More information

MULTI-RESIDENTIAL BUILDING SOLUTIONS

MULTI-RESIDENTIAL BUILDING SOLUTIONS MULTI-RESIDENTIAL BUILDING SOLUTIONS OUR EXPERTISE AT YOUR SERVICE Canam has been offering owners, real estate developers, architects, engineers and contractors an array of construction solutions since

More information

SECTION STEEL JOIST FRAMING

SECTION STEEL JOIST FRAMING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 05 21 00 1. Use this section only for NCA projects. 2. Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable

More information

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1 Fitness Facility Addition Page 1 PART 1 GENERAL 1.1 SECTION INCLUDES.1 Extruded aluminum windows with fixed sash..2 Factory glazed..3 Perimeter sealant. 1.2 RELATED SECTIONS.1 Section 05500 - Metal Fabrications.2

More information

Foil Back Gypsum Board

Foil Back Gypsum Board BRAND 09 29 00/NGC Foil Back Gypsum Board brand Foil Back Gypsum Board consists of a fire-resistant gypsum core with a heavy, natural finish and 100-percent recycled paper on the face and a strong liner

More information

SECTION METAL DOORS & FRAMES

SECTION METAL DOORS & FRAMES SECTION 08100 METAL DOORS & FRAMES PART 1 GENERAL 1.1 SCOPE Drawings and general provisions of the Contract, including General and Supplementary General Conditions and other Division 00 & 01 specification

More information

GA APPLICATION OF GYPSUM SHEATHING

GA APPLICATION OF GYPSUM SHEATHING 1. Scope 1.1 This specification describes the minimum requirements for, and the methods of handling, storage, and application of, gypsum sheathing for use as a substrate for exterior claddings. 1.1.1 Exterior

More information

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2) Inspection of Fabricators (1704.2) Furnish inspection reports (1704.2.1) - Fabricators that have not been approved Provide a Certificate of Compliance (1704.2.2) - Approved Fabricators Steel Construction

More information

SOTA THERMO 3 SERIES SPECIFICATION FOR PREGLAZED & UNITIZED THERMO 3 CURTAINWALL SYSTEM

SOTA THERMO 3 SERIES SPECIFICATION FOR PREGLAZED & UNITIZED THERMO 3 CURTAINWALL SYSTEM 1. General 1.1 Description of Work a. Furnish the labour, materials and other services to complete the fabrication and installation of Thermo 3 Series framing, including all materials and fitments required

More information

AMBICO Limited Section and STAINLESS STEEL DOORS AND FRAMES Page 1

AMBICO Limited Section and STAINLESS STEEL DOORS AND FRAMES Page 1 Page 1 This section includes standard commercial Stainless Steel Doors and Frames. This section relies on both the Canadian Steel Door Manufacturers Association (CSDMA.org) industry standard, as well as

More information

Statement of Special Inspections

Statement of Special Inspections Statement of Special Inspections SUCF Project No: Project Title: Registered Design Professionals in Responsible Charge: (Name) (Address) Architect: Structural Engineer: Mechanical Engineer: Identification

More information

TECHNICAL EVALUATION REPORT No. 27/2008/2060

TECHNICAL EVALUATION REPORT No. 27/2008/2060 TECHNICAL EVALUATION REPORT No. 27/2008/2060 Sheet 1 of 16 Sheets This report is a correct record of the measurements and observations made. The report is intended for the private information of those

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 053100 STEEL DECKING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS PRODUCTION SPECIFICATIONS SECTION 03135 INSULATED CONCRETE FORMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Insulated panel permanent concrete form system for: 1. Exterior structural wall panels. 2. Interior

More information

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS PRODUCTION SPECIFICATIONS SECTION 03135 INSULATED CONCRETE FORMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Insulated panel permanent concrete form system for: 1. Exterior structural wall panels. 2. Interior

More information

Omniplate Barrier Wall System

Omniplate Barrier Wall System is an economical barrier wall system with visible caulk joints at all horizontal and vertical panel joints. As a barrier wall, serves as the primary weather barrier for the building envelope. It can be

More information

AMBICO Limited 7\2018 Section and OVERSIZED METAL DOORS AND FRAMES Page 1

AMBICO Limited 7\2018 Section and OVERSIZED METAL DOORS AND FRAMES Page 1 Page 1 This section includes Oversize Steel Doors and Frames and relies on the Canadian Steel Door Manufacturers Association (CSDMA.org) industry standard, as well as on the Hollow Metal Manufacturers

More information

1.02 SYSTEM DESCRIPTION

1.02 SYSTEM DESCRIPTION 1 OF 7 MODULAR MEZZANINES GUIDE SPECIFICATIONS FOR PART 1 - GENERAL 1.01 RELATED WORK A. SECTION 03 30 00: Cast in Place Concrete (and Concrete Finishing) 1. The area where mezzanine is installed shall

More information

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM STORM WINDOWS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 08 51 69.11 ALUMINUM STORM WINDOWS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable

More information

SECTION CEMENTITIOUS WOOD FIBER DECKS

SECTION CEMENTITIOUS WOOD FIBER DECKS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 03 51 13 CEMENTITIOUS WOOD FIBER DECKS SPEC WRITE NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 092216 - COLD FORMED STEEL FRAMING - NON-STRUCTURAL (CFSF-NS) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 ACTION

More information

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1. PAGE 1 PART 1 GENERAL 1.1 REFERENCE.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1. 1.2 RELATED WORK SPECIFIED ELSEWHERE.1 Masonry

More information

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer) NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION MASTERFORMAT SECTION 04818 (Mortarless Concrete Brick Veneer) Spec_USA_En_18102005.doc 12/1/2005 Novabrik Page 2 Section 04818 NOVABRIK MORTARLESS

More information

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651 SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651 PART 1 GENERAL 1.1 DESCRIPTION A. Work Included: 1. Furnish all labor and materials to complete the fabrication of detention windows

More information

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 08110 - STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division 1 Specification

More information

DIVISION 5 METALS BUSHEY FEIGHT MORIN ARCHITECTS INC. 473 NORTH POTOMAC STREET HAGERSTOWN, MARYLAND FAX:

DIVISION 5 METALS BUSHEY FEIGHT MORIN ARCHITECTS INC. 473 NORTH POTOMAC STREET HAGERSTOWN, MARYLAND FAX: DIVISION 5 METALS BUSHEY FEIGHT MORIN ARCHITECTS INC. 473 NORTH POTOMAC STREET HAGERSTOWN, MARYLAND 21740 301-733-5600 FAX: 301-733-5612 SECTION 05400 - COLD FORMED METAL FRAMING PART 1 GENERAL 1.1 SECTION

More information

A division of Canam Group

A division of Canam Group s and Girders Catalogue A division of Canam Group TABLE OF CONTENTS Products, services and solutions.... 4 General information The advantages of using steel joists... 5 Description of a joist girder....5

More information

SOTA HYBRID-WALL SPECIFICATION FOR PRE-GLAZED & UNITIZED HYBRID-WALL SYSTEM

SOTA HYBRID-WALL SPECIFICATION FOR PRE-GLAZED & UNITIZED HYBRID-WALL SYSTEM 1. General 1.1 Description of Work a. Furnish the labour, materials and other services to complete the fabrication and installation of Hybrid-Wall Series framing, including all materials and fitments required

More information

CTB Commercial Aluminum Window

CTB Commercial Aluminum Window Technical Information Description The is thermally-broken for use in commercial construction. Basic models include horizontal slider, single hung and fixed picture windows. Units are mulled together with

More information

Master Specification ENERTITE by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

Master Specification ENERTITE by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1 Page 1 ENERTITE 1-2-1 by BASF Canada Inc, is a thermal insulation intended for building enclosures, located in appropriate assembly locations in buildings during enclosure construction. This section includes

More information

SECTION WALL AND DOOR PROTECTION

SECTION WALL AND DOOR PROTECTION PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 26 00 WALL AND DOOR PROTECTION SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable to

More information

Arcwall. Rain Screen Wall System

Arcwall. Rain Screen Wall System Rain Screen Wall System is an economical drained and back-ventilated rain screen system for both walls and soffits manufactured from formed aluminum or stainless plate. The system combines excellent performance

More information

Arcwall. Rain Screen Wall System

Arcwall. Rain Screen Wall System Arcwall Rain Screen Wall System Arcwall is an economical drained and back-ventilated rain screen system for both walls and soffits manufactured from formed aluminum or stainless plate. The system combines

More information

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651 SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651 PART 1 GENERAL 1.1 DESCRIPTION A. Work Included: 1. Furnish all labor and materials to complete the fabrication of detention windows as

More information

Unitised Curtain Wall Beaded

Unitised Curtain Wall Beaded Unitised Curtain Wall Beaded Glazed Frame Unitised Curtain Wall Reference Brand: Sapa Building System Elegance 72 GF GENERAL DESCRIPTION Unitised curtain wall system using glazing beads for glass retention.

More information

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD AND TRACK FOR DRYWALL PARTITIONS TAKE ADVANTAGE OF THE SAVINGS IN TIME

More information

AMBICO Limited Section and ACOUSTIC STEEL WINDOW FRAME ASSEMBLIES Page 1

AMBICO Limited Section and ACOUSTIC STEEL WINDOW FRAME ASSEMBLIES Page 1 Page 1 This section includes AMBICO Acoustic Steel Window Frames that are glazed as part of a complete assembly. Items are designed to be fixed-in place and shall be inoperable. These items are an integral

More information

SECTION ** NOTE TO SPECIFIER ** Overhead Door Corp.; Residential Sectional Overhead Door products.

SECTION ** NOTE TO SPECIFIER ** Overhead Door Corp.; Residential Sectional Overhead Door products. SECTION 08 36 13 RESIDENTIAL OVERHEAD DOORS IMPRESSION COLLECTION INSULATED FIBERGLASS DOORS SERIES 980 Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions

More information

1. Division 01: Administrative, procedural, and temporary work requirements.

1. Division 01: Administrative, procedural, and temporary work requirements. SECTION 10 2219 DEMOUNTABLE PARTITIONS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Demountable partition system. 2. Doors. 3. Glazed panels. B. Related Sections: 1. Division 01: Administrative,

More information

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System SECTION 13096 RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13096-1 RF MODULAR PAN SYSTEM PART 1 GENERAL 1.1

More information

AMBICO Limited Section WOOD SOUND CONTROL DOOR AND STEEL FRAME ASSEMBLIES Page 1

AMBICO Limited Section WOOD SOUND CONTROL DOOR AND STEEL FRAME ASSEMBLIES Page 1 Page 1 This section includes AMBICO acoustic wood doors and steel frames, fire rated and non-rated. and relies on both Canadian Steel Door Manufacturers Association (CSDMA) and the Hollow Metal Manufacturers

More information

603 Summit Avenue, Suite 102 Greensboro, N.C Voice/FAX (336)

603 Summit Avenue, Suite 102 Greensboro, N.C Voice/FAX (336) Ricky L. Loman, AIA Architect 603 Summit Avenue, Suite 102 Greensboro, N.C. 27405-7700 Voice/FAX (336) 273-7999 ADDENDUM: Number 1 ISSUED: March 14, 2017 SUBJECT: New Agriculture & Equipment Storage Barn

More information

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section. SECTION 10 5300 ALUMINUM WALKWAY COVERS Part 1 General 1.01 Related Documents A. The requirements of Division 1 specifications shall apply to work specified in the section. 1.02 References A. International

More information

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS [OR WOOD] PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

Gold Bond BRAND Kal-Kore Plaster Base

Gold Bond BRAND Kal-Kore Plaster Base BRAND 09 29 22 00/NGC 39/NGC Kal-Kore Plaster Base brand Kal-Kore Plaster Base is a tapered-edge gypsum plaster base with 100-percent recycled gray absorptive face paper surface designed to permit rapid

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09 PART 1 - GENERAL 1.01 SUMMARY A. Types of cold-formed metal framing units include the following: 1. C-shaped steel studs B. Related work specified elsewhere includes but may not be limited to: 1. Section

More information

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION PLATE CONNECTED WOOD TRUSSES SECTION 06173 PLATE CONNECTED WOOD TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shop fabricated wood trusses for roof and floor framing. 2. Bridging, bracing, and anchorage. B. Related Sections:

More information

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS SECTION 08361 RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES. A.

More information

4600 Series Specifications (Section 08520)

4600 Series Specifications (Section 08520) 4600 Series Specifications (Section 08520) I. GENERAL: 1.01 Scope of Work A. Furnish all necessary materials, labor, and equipment for the complete installation of aluminum windows for this project as

More information