1 Consistent blanket thickness and uniform fiber distribution provides efficient and hassle-free cutting and pinning on all fabrication processes. Ultra-fast Roto Zip processessing speed with Knauf Sonic XP Duct Liner. Knauf Exeed Insulation LLC Mussafah ICAD1 P.O. Box 34332, Abu Dhabi, UAE Tel Fax Stands up to abuse Sonic XP Duct Liner s tough mat facing is durable enough to withstand shop and job site wear and tear. sales@kei.ae The encapsulant edge coating eliminates airstream flaring. The natural brown base blanket with ECOSE Technology binder has no added phenol, formaldehyde, acrylics, artificial colors or UREA. LEED Eligible Product Use of this product may help building projects meet green building standards as set by the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. MR Credit Recycled Content MR Credit Regional Materials Data Sheet November 2013 Facts at a glance Excellent sound absorption reduces noise from fans, mechanical equipment, cross-talk and air movement. NRC rating of.70 (1.5 PCF, 1 ). More cost-effective than alternative closed cell duct liners. GREENGUARD Gold and Formaldehyde Free Knauf Sonic XP Duct Liner with ECOSE Technology is certified by UL Environment for indoor air quality as low emitting products, have achieved GREENGUARD Gold certification and are verified to be formaldehyde free. Sonic XP Duct Liner with ECOSE Technology Certified for indoor air quality as a low emitting product by UL Environment. ECOSE Technology is a revolutionary binder based on rapidly renewable bio-based materials rather than non-renewable petroleum-based chemicals such as phenol, formaldehyde, acrylics, artificial colors or UREA.

2 Sonic XP Duct Liner with ECOSE Technology Description Knauf Insulation Sonic XP Duct Liner with ECOSE Technology is a flexible, mat-faced insulation bonded with ECOSE Technology. It is faced with a tightly bonded mat to give the airstream a smooth, tough surface, resisting damage during installation and operation. The encapsulant edge coating eliminates airstream flaring. ECOSE Technology ECOSE Technology is a revolutionary binder chemistry that makes Knauf Insulation products even more sustainable than ever. It features rapidly renewable bio-based materials rather than nonrenewable petroleum-based chemicals traditionally used in Glass Mineral Wool insulation products. ECOSE Technology reduces binder embodied energy and does not contain phenol, formaldehyde, acrylics, artificial colors or UREA. Specifically designed as an interior insulation material for sheet metal ducts used in heating, ventilating and air conditioning. Provides an optimum combination of efficient sound absorption, low thermal conductivity and minimal airstream surface friction. Features and Benefits Low thermal conductivity Fire-resistant, non-corrosive, durable and resilient Tough, tightly bonded mat facing Excellent sound absorption Energy conservation Better temperature control Lowers operating costs Greatly reduces noise from fans and mechanical equipment as well as cross-talkand air movement Withstands damage from normal handling and shop abuse If necessary, can be cleaned in accordance with NAIMA s Cleaning Glass Mineral Wool Insulated Air Duct Systems Recommended Practices. Knauf Insulation achieved GREENGUARD Gold Certification and is verified to be formaldehyde free. Products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. Knauf Insulation has achieved a UL Environment claim validation for over 50% post-consumer recycled glass content in our insulation products. Sustainability Carbon negative: meaning Knauf Insulation products used for thermal insulating purposes recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. Glass Mineral Wool insulation with ECOSE Technology contains three primary ingredients: Sand, one of the world s most abundant and renewable resources A minimum 60% recycled post-consumer glass content and UL Environment verification every 6 months ECOSE Technology which reduces binder embodied energy by up to 70% Specification Compliance ASTM C 1071; Type I ASTM G 21 GREENGUARD Certified GREENGUARD Gold Certified and is verified to be formaldehyde free NFPA 90A and 90B Technical Data UL/ULC classified Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, CAN/ULC S102-M88, NFPA 255 and UL 723 Temperature Range (ASTM C 411) Up to 250 F (121 C) Air Velocity (ASTM C 1071) Maximum 6000 fpm (1829 mpm) Tested to 15,000 fpm (4572 mpm) Corrosiveness (ASTM C 665) Does not accelerate corrosion on steel, copper or aluminum Corrosion (ASTM C 1617) The corrosion rate in mils/yr will not exceed that of the 1 ppm chloride solution. Water Vapor Sorption (ASTM C 1104) Less than 3% by weight Water Repellency (INDA IST ) 4 Microbial Growth (ASTM C 1338) Airstream surface mat facing is treated with an EPA-registered anti-microbial agent to aid in the prevention of fungal and bacterial growth. Does not promote or support the growth of mold, fungi or bacteria. Microbial Resistance Using the GREENGUARD protocol, Sonic XP Duct Liner is considered to be Resistant to Mold Growth. & Specification Guidelines Storage Inside storage is recommended. Fabrication and Fabricate in compliance with the latest edition of NAIMA s Glass Mineral Wool Duct Liner Standard. Liner shall be folded and compressed in the corners of rectangular duct sections or shall be cut and fit to assure lapped, compressed joints. Longitudinal joints in duct liner should not occur except at the corner of ducts. Longitudinal joints in liner shall be coated with adhesive. All damaged areas of the air stream surface shall be repaired with an adhesive which conforms to ASTM C 916. Liner should be adhered to the duct with 90% minimum area coverage of an adhesive which conforms to ASTM C 916. Mechanical fasteners should not compress the insulation more than ⅛" (3 mm), and shall be installed perpendicular to the duct surface. All fasteners should comply with the guidelines of NAIMA s Glass Mineral Wool Duct Liner Standard and the Mechanical Fastener s Standard MF Metal nosings shall be securely installed over transversely oriented liner edges facing the airstream at fan discharge, at access doors and at any interval of lined duct preceded by unlined duct. In addition, where velocities exceed 4000 fpm (1219 mpm), metal nosing small be used on upstream edges of liner at every transverse joint (See illustration) Limitations Knauf Sonic XP Duct Liner with ECOSE Technology should not be used in systems operating at velocities exceeding 6000 fpm (1829 mpm) or at temperatures above 250 F (121 C). Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold, it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Air handling insulation used in the air stream must be discarded if exposed to water. Thermal Conductance C * and Resistance R (ASTN C 177) Mean Temperature 75 F (24 C) Product Conductance C Resistance R 1.5 PCF 1" (24 kg/m 3 25 mm).24 (1.42) 4.2 (.74) 1.5 PCF 1.5" (24 kg/m 3 38 mm).17 (.97) 6.0 (1.06) 1.5 PCF 2" (24 kg/m 3 51 mm).13 (.74) 8.0 (1.41) 2.0 PCF.5" (32 kg/m 3 13 mm).48 (2.73) 2.1 (.37) 2.0 PCF 1" (32 kg/m 3 25 mm).24 (1.36) 4.2 (.74) 2.0 PCF 1.5" (32 kg/m 3 38 mm).16 (.91) 6.3 (1.11) C Units: * The lower the value, the better the performance. The higher the value, the better the performance. Forms Available BTU ft² hr F Density Thickness** Width Length 1.5 PCF 1" 1.5 PCF 1.5" 1.5 PCF 2" W m² C R Units: Notes The chemical and physical properties of Knauf Sonic XP Duct Liner with ECOSE Technology represent typical average values determined in accordance with accepted test methods. The data is subject to normal manufacturing and testing variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. When condensation is permitted to occur between nested Sonic XP Duct Liner and galvanized steel panels, discoloration of the metal may occur. Check with your Knauf Insulation sales representative to assure information is current. ft² hr F BTU 34"- 36"* (864 mm mm) 46" - 48" (1168 mm mm) 56" - 72" (1422 mm mm) m² C W 50' (15.24 m) 100' (30.48 m) 140 (42.67 m) 200 (60.96 m) 50' (15.24 m) 90 (27.43 m) 50' (15.24 m) 100' (30.48 m) 2.0 PCF.5" 100 (30.48 m) 50 (15.24 m) 2.0 PCF (30.48 m) *Widths of not available with edge coating. **Non-standard widths for all.5, 1, 1.5, and 2 products from 34-36, and are available in 25 (6.35 mm) increments of minimum order quantity. Sound Absorption Coefficients (ASTM C 423, Type A Mounting) Octave Band Center Frequency (cycles/sec.) Type NRC 1.5 PCF 1" (24 kg/m 3 25 mm) PCF 1.5" (24 kg/m 3 38 mm) PCF 2" (24 kg/m 3 51 mm) PCF.5" (32 kg/m 3 13 mm) PCF 1" (32 kg/m 3 25 mm) PCF 1.5" (24 kg/m 3 38 mm) Coefficients determined per ASTM E 795 Type A Mounting. NOTE: ASHRAE Handbook for HVAC s Sound and Vibration Control contains insertion loss values for lined sheet metal ducts. Friction Loss (Inches of water per 100') FPM Hydraulic Diameter Velocity 10" 16" 24" 32" 40" 72" 100" Mechanical Fastener Location Velocity/FPM (meters/second) A From corners of duct B From transverse of duct C Across width of duct, on centers (min. 1/side) D Across length of duct, on centers (min. 1/side) (0-12.7) 4" (102 mm) 3" (76 mm) 12" (305 mm) 18" (457 mm) Liner Interior Width ( ) 4" (102 mm) 3" (76 mm) 6" (152 mm) 16" (406 mm) No. Pins Inches (mm)

3 Knauf Exeed Insulation LLC Mussafah ICAD1 P.O. Box 34332, Abu Dhabi, UAE Tel Fax sales@kei.ae LEED Eligible Product Use of this product may help building projects meet green building standards as set by the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. Credit Recycled Content Credit Regional Materials Data Sheet November 2013 Knauf Elevated Temperature Board with ECOSE Technology products are certified for indoor air quality as low emitting products by the GREENGUARD Environmental Institute to both the GREENGUARD Indoor Air Quality Certification Program SM and the more stringent GREENGUARD Children & Schools SM standard and are verified to be formaldehyde free. The GREENGUARD Indoor Air Quality Certified Mark is a registered certification mark used under license through the GREENGUARD Environmental Institute. Elevated Temperature Board with ECOSE Technology

4 Elevated Temperature Board with ECOSE Technology Description Knauf Insulation Elevated Temperature Board with ECOSE Technology is a lightweight insulation (2.8 pcf, 44.9 kg/m 3 ) bonded with ECOSE Technology. It is a semi-rigid, board-like form with superior handling properties and insulating effectiveness at minimum cost. ECOSE Technology ECOSE Technology is a revolutionary binder chemistry that makes Knauf Insulation products Sustainability Carbon-negative - meaning: Knauf Insulation products used for thermal insulating purposes recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. Glass Mineral Wool insulation with ECOSE Technology contains three primary ingredients: order to protect against any harmful fumes and vapors that might be generated. Storage Protect material from water damage or other abuse. Cartons are not designed for outside storage. Vacuum packaged material can be stored outside if care is taken not to puncture the polybag. Preparation Apply the product on clean, dry surfaces. Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Thermal Efficiency (ASTM C 177) even more sustainable than ever. It features rapidly renewable bio-based materials rather than nonrenewable petroleum-based chemicals traditionally used in Glass Mineral Wool insulation products. ECOSE Technology reduces binder embodied energy and does not contain phenol, formaldehyde, acrylics, artificial colors or UREA. Knauf Insulation Elevated Temperature Board with ECOSE Technology is used for boiler walls, hot precipitators, hot ductwork, cylindrical tanks, towers, stacks and industrial ovens. Features and Benefits Excellent Thermal Properties Reduces operating cost. Low Installed Cost Lightweight. Easy to fabricate. Packaging- Cartons and Sleeves Damage resistant. Reduces storage space. Resiliency Maintains integrity at elevated temperatures. Indoor Air Quality Knauf Insulation achieved GREENGUARD GOLD Certification and is verified to be formaldehyde free. Products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. Knauf Insulation has achieved a UL Environment claim validation for over 50% postconsumer recycled glass content in our insulation products. Sand, one of the world s most abundant and renewable resources A minimum 60% recycled post-consumer glass content and UL Environment verification every 6 months ECOSE Technology which reduces binder embodied energy by up to 70% and total product embodied energy by up to 4%. Specification Compliance UL Classified Conforms to Marine Equipment European 1408/13 ASTM C 612; Type IA, IB, II ASTM C 795 GREENGUARD Certified GREENGUARD GOLD SM Technical Data UL/ULC Classified Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, CAN/ULC S102-M88, NFPA 255 and UL 723. Temperature Limitation (ASTM C 411) Up to 842 F (450 C). Corrosiveness (ASTM C 665) Does not accelerate corrosion on steel Corrosion (ASTM C 1617) The corrosion rate in mils/yr will not exceed that of the 1 ppm chloride solution. Resists Microbial Growth (ASTM C 1338) Does not support microbial growth. and Specification Guidelines Precaution During initial heat-up to operating temperatures above 350 F (177 C), a slight odor and some smoke may be given off as a portion of the All insulation joints must be firmly butted. Mount flush against surfaces to 842 F (450 C) or use in panels mounted away from operating surface. Knauf Insulation ET Board is designed to be applied over welded pins and/or studs up to 1/2" (13 mm) in diameter. The board is to be held in place by speed washers, tension clips or metal mesh reinforcement. Installation method should not compress material beyond maximum of 5% at any point. Pins and studs shall be located a maximum of 4" (102 mm) from each edge and spaced no greater than 16" (406 mm) on center. In temperatures over 550 F (288 C) and designed thickness over 3" (76 mm) dual layer application with staggered joints is recommended. Install thickness recommended by Knauf Insulation or NAIMA 3E Plus program. Finish surface with metal cover, or with insulating cement and canvas. Packaging Vacuum packaging Knauf Insulation Elevated Temperature Board will reduce some mechanical properties of the insulation. By ordering vacuum packaged products, the customer acknowledges these reduced properties and assumes responsibility for the fitness for use in their application. Caution Glass Mineral Wool may cause temporary skin irritation. Wear long-sleeved, loose-fitting clothing, head covering, gloves and eye protection when handling and applying material. Wash with soap and warm water after handling. Wash work clothes separately and rinse washer. A disposable mask designed for nuisance type dusts should be used where sensitivity to dust and airborne particles may cause irritation to the nose or throat. Notes The chemical and physical properties of Knauf Elevated Temperature Board with ECOSE Technology represent typical average values determined in accordance with accepted test methods. The data is subject to normal manufacturing variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. Check with your Knauf Insulation sales representative to assure information is current. Mean Temperature k k(si) 100 F (38 C) F (93 C) F (149 C) F (204 C) F (260 C) Forms Available Thickness Width Length 1'' (25 mm) 1½'' (38 mm) 2'' (51 mm) 0.6 m 1.2 m 2½'' (64 mm) and to 3'' (76 mm) 1.2 m 3.0 m 3½'' (89 mm) 4'' (102 mm) bonding material used in the insulation begins to undergo a controlled decomposition. If natural convection is not adequate in confined areas, forced ventilation should be provided in

5 Knauf Insulation s black mat surface provides a darker black than other standard boards, minimizing visibility at venting points. Lower installed cost than lined and wrapped sheet metal ducts. Knauf Exeed Insulation LLC Mussafah ICAD1 P.O. Box 34332, Abu Dhabi, UAE Tel Fax sales@kei.ae The consistent density of Knauf Insulation Eclipse Air Duct Boards with ECOSE Technology helps prevent tenting and makes fabrication and handling in the shop and on the job site fast and easy. Quiet, efficient air delivery, plus excellent temperature control. Knauf Insulation Eclipse Air Duct Board with ECOSE Technology has a molded shiplap edge on all thicknesses, giving a tighter seal and a stronger joint. LEED Eligible Product Use of this product may help building projects meet green building standards as set by the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. Credit Recycled Content Credit Regional Materials Data Sheet November 2013 Facts at a glance For cooling, heating or dual-temperature service Duct construction and insulation in one fabrication Excellent Acoustic Performance Knauf Insulation Eclipse Air Duct Board with ECOSE Technology products are certified for indoor air quality by The GREENGUARD Environmental Institute, to both the GREENGUARD Certification Program SM and the more stringent GREENGUARD For Children and Schools Standard. The GREENGUARD INDOOR AIR QUALITY CERTIFIED Mark is a registered certification mark used under license through the GREENGUARD Environmental Institute. Eclipse Air Duct Board with ECOSE Technology

6 Eclipse Air Duct Board with ECOSE Technology Description Knauf Insulation Eclipse Air Duct Board with ECOSE Technology is a rigid Glass Mineral Wool board faced on one side with a foil-scrim-kraft (FSK) vapor retarder and with a lightweight black Glass Mineral Wool mat on the airstream surface. It is used to fabricate rectangular or Max 10 air duct systems. It comes with two stiffness ratings, EI-475 and EI-800. Both types are available with butt edge or factory molded male-female shiplap edges. The airstream surface of Knauf Insulation Eclipse Air Duct Board is treated with an EPA registered, anti-microbial agent that prevents growth of mold, fungus or bacteria in accordance with ASTM C1071, G21. ECOSE Technology ECOSE Technology is a revolutionary binder based on rapidly renewable bio-based materials rather than non-renewable petroleum-based chemicals such as phenol, formaldehyde or acrylics. ECOSE Technology reduces Knauf Insulation s binder embodied energy and contains no phenol, formaldehyde, acrylics, artificial colors or UREA found in traditional Glass Mineral Wool insulation. Knauf Insulation Eclipse Air Duct Board with ECOSE Technology is designed for commercial and residential air handling installations for cooling, heating or dual-temperature service where good temperature control and noise absorption are required. Features Low thermal conductivity of 0.23 at 75 F (24 C) mean temperature. Low installed cost insulated duct system. Excellent acoustical characteristics. Dark black glass mat airstream surface. Assured insulation thickness, shiplap joints and FSK vapor retarder. If necessary, can be cleaned in accordance with NAIMA s Cleaning Glass Mineral Wool Insulated Air Duct Systems Recommended Practices. Knauf Insulation Eclipse Air Duct Board systems meet the fire and smoke safety regulations of most federal, state and local building codes. Fabrication in shop or on jobsite. Certified for indoor air quality as a low emitting product by The GREENGUARD Environmental Institute to both the GREENGUARD Certification Program SM and the more stringent GREENGUARD Children and Schools SM standard. Sustainability Carbon negative: meaning Knauf Insulation s products used for thermal insulating purposes recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. Glass Mineral Wool insulation with ECOSE Technology contains three primary ingredients: Sand, one of the world s most abundant and renewable resources A minimum 60% recycled post-consumer glass content and UL Environment verification every 6 months ECOSE Technology which reduces binder embodied energy by up to 70% It is anticipated to reduce its Global Warming Potential (GWP) by approximately 4%, a significant reduction in our carbon footprint Benefits Fabrication in shop environment lowers field installation time. One craft required to fabricate and install system. Minimum capital investment for fabrication equipment. Portability allows for assembly or fabrication at job site. Black mat facing ensures a smoother airstream surface for a cleaner cut and added durability. Lower installation cost than with duct wrap and duct liner with sheet metal. Finished internal duct appearance is black. Quiet, efficient air delivery. Reduces noise generated by air turbulence and mechanical equipment. Eliminates booming and cracking sounds caused by sheet metal duct contraction and expansion. Condensation control. Strong thermal performance. Code compliance. Specification Compliance ASTM C 1136; Type II (FSK facing) ASTM G 21 GREENGUARD Indoor Air Quality Certified GREENGUARD Children and Schools Certified SM NFPA 90A and 90B UL 181; Class 1 Technical Data UL listed. Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, CAN/ULC S102-M88, NFPA 255 and UL 723. Flexural Rigidity Available in two stiffness values: EI-475 and EI-800. Flexural rigidity (EI) is the product of Young s modulus of elasticity (E) and moment of inertia (I) as determined in accordance with NAIMA AHS Service Temperature (ASTM C 411) Up to 250 F (121 C). Air Velocity (UL 181) Maximum 5000 fpm (1524 mpm). Tested to 12,500 fpm (3810 mpm). Corrosiveness (ASTM C 665) Does not accelerate corrosion on steel, copper or aluminum. Corrosion (ASTM C 1617) The corrosion rate in mils/yr will not exceed that of the 1 ppm chloride solution. Internal Static Pressure (UL 181) Maximum ±2 water (498 pascals [Pa]). Water Vapor Transmission Rate (ASTM E 96) Less than 0.02 perms. Water Vapor Sorption (ASTM C 1104) Less than 5% by weight. Microbial Growth (ASTM G 21, UL 181) Does not promote or support the growth of mold, fungi or bacteria. Microbial Resistance Using the GREENGUARD protocol, Eclipse Air Duct Board is considered to be Resistant to Mold Growth. and Specification Guidelines Storage Protect stored duct board from water damage, construction damage and other abuse. If stored outside, proper protection from weather conditions should be provided. Sound Absorption Coefficients (ASTM C 423, Type A Mounting) Octave Band Center Frequency (Cycles/Sec.) Type NRC EI-475-1'' (25 mm) EI '' (38 mm) EI-800-2'' (51 mm) Forms Available Friction Loss (Inches of water per 100') Thickness Size* Edge Pieces/Carton 1'' (25 mm) 48'' x 96'' (1219 mm x 2438 mm) Shiplap 8 1'' (25 mm) 48'' x 120'' (1219 mm x 3048 mm) Butt, Shiplap 6 1.5'' (38 mm) 48'' x 120'' (1219 mm x 3048 mm) Shiplap 4 2'' (51 mm) 48'' x 120'' (1219 mm x 3048 mm) Butt, Shiplap 3 * Other lengths also available as per customer requirement FPM Hydraulic Diameter Velocity 10'' 16'' 24'' 32'' 40'' 72'' 100'' Recommended Maximum Duct Dimensions Without Reinforcement* EI-475-1" EI-800-1", 1-1/2", 2" Internal Pressure Inches of Water.5 (125) 1.0 (249) 2.0 (498).5 (125) 1.0 (249) 2.0 (498) Positive 36" (914 mm) 24" (610 mm) 15" (381 mm) 36" (914 mm) 24" (610 mm) 18" (457 mm) Negative 34" (864 mm) 24" (610 mm) 14" (356 mm) 36" (914 mm) 24" (610 mm) 18" (457 mm) * This table summarizes span/pressure limitations for unreinforced duct. For larger ducts, refer to NAIMA s Glass Mineral Wool Duct Construction Standard, or Knauf s Air Duct Fabrication Manual. (Pressure Pascals [Pa]) Thermal Resistance R (ASTM C 518) Mean Temperature 75 F (24 C) Thickness R-Value (R.S.I.) 1'' (25 mm) 4.3 (.76) 1.5'' (38 mm) 6.5 (1.14) 2'' (51 mm) 8.7 (1.53) R Units: ft 2 hr F m 2 C BTU W ( ) Thermal Conductivity k (ASTM C 177) Mean Temperature 75 F (24 C) k-value EI-475 and EI (.033) BTU in W k Units: ft 2 hr F ( ) m C Duct shall be fabricated and installed in strict accordance with NAIMA s Glass Mineral Wool Duct Construction Standard, Residential Standard, 1½" Fabrication Manual or Knauf Insulation Air Duct Fabrication Manual in accordance with the conditions of UL 181 listing. Duct systems shall have all transverse joints, longitudinal seams and duct wall penetrations sealed using 3" (76 mm) wide glass fabric and mastic, 2" (51 mm) minimum width heat sealable tape or 2" (51 mm) minimum width pressure sensitive tape with acrylic adhesive. Rubberbased adhesives are not approved. Only UL 181-A listed and labeled products shall be used for closure systems. A listing of specific approved closure products is available from your local Knauf Insulation sales representative. PRESSURE SENSITIVE TAPES: Only those tapes listed under and imprinted with designation UL 181-A-P and registered with UL. HEAT SEALABLE TAPES: Only those tapes listed under and imprinted with the designation UL 181 A-H and registered with UL. MASTICS: Mastic systems listed and registered with UL and carrying the designation UL 181 A-M used in conjunction with a 3" (76 mm) wide glass fabric. Procedures 1. PRESSURE SENSITIVE TAPE: a. All longitudinal and circumferential joints must be stapled with outward flaring, ½" (13 mm) minimum length staples 2" (51 mm) on centers. b. If necessary, follow the recommendations of the tape manufacturer for cleaning the surface to be taped. c. Center tape over staple flap and rub tape firmly in place immediately after application, using a plastic squeegee or similar tool, until the scrim reinforcement of the duct board facing can be clearly seen through the tape. d. A heat-sealing iron must be used to assure a good bond when installed below 50 F (10 C). e. Tape should not be applied to surface of duct board when temperature is below 32 F (0 C) due to the possibility of entrapping ice crystals which, upon melting, will cause tape to loosen. Heat duct board facing surface first to drive off moisture. 2. HEAT SEALABLE TAPE: a. All longitudinal and circumferential joints must be stapled with outward flaring, ½" (13 mm) minimum length staples 2" (51 mm) on centers. b. If necessary, follow the recommendations of the tape manufacturer for cleaning the surface to be taped. c. Center tape over staple flap and seal down tape end with 500 F (260 C) iron. Do not use heat gun; both heat and pressure are required to effect a seal. d. Press down entire length of tape with iron using a smearing action to get a good bond. Be sure edges are sealed. e. Staples may be omitted when an automatic closure machine such as the Glassmaster Closemaster is used. In this case, iron temperature must be set at 650 F (343 C) minimum. Continuous production may require periodic pauses to allow sealing iron temperature to recover to the 650 F (343 C) minimum. f. Allow joint to cool before stressing. 3. MASTIC AND GLASS FABRIC: a. All longitudinal and circumferential joints must be stapled with outward flaring, ½" (13 mm) minimum length staples 2" (51 mm) on centers. b. Brush approved mastic onto joint and embed 3" (76 mm) wide glass fabric in mastic. c. Brush second coat of mastic over glass fabric until mesh is completely filled. d. Follow mastic manufacturer s instructions on curing the mastic prior to subjecting the joint to stress. Closure If the closure system used is not one of the approved systems described above and if application is not in accordance with stated procedures, Knauf Insulation assumes no liability for duct system performance. Use of a non-ul registered and listed closure voids the UL 181 Class 1 rating as well as Knauf Insulation s product performance warranties. Reinforcements Duct sections shall be additionally reinforced where necessary, according to Knauf Insulation and NAIMA standards. Ductwork shall be supported as required on straight runs, at all turns and at transitions to maintain proper alignment. Hangers and supports shall be in strict accordance with Knauf Insulation and NAIMA standards. Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Air handling insulation used in the air stream must be discarded if exposed to water. Notes When used in accordance with NAIMA s and Knauf Insulation s application instructions, the closure systems described herein meet UL 181 requirements, and the resulting system carries a Class 1 Air Duct rating. This data sheet is not intended to be a design or fabrication manual. For specific details and recommendations on fabrication, reinforcement, hanging and other details, refer to the latest edition of the NAIMA Glass Mineral Wool Duct Construction Standard, Residential Standard, 1½ Fabrication Manual or Knauf Insulation Air Duct Fabrication Manual. and installation procedure is at the discretion of and is the responsibility of the Design Engineer to meet specific job requirements. The chemical and physical properties of Knauf Insulation Eclipse Air Duct Board with ECOSE Technology represent typical average values determined in accordance with accepted test methods. The data is subject to normal manufacturing and testing variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. Check with your Knauf Insulation sales representative to assure information is current.

7 Knauf Exeed Insulation llc Mussafah ICAd1 P.O. Box 34332, Abu dhabi, UAE Tel Fax sales@kei.ae leed Eligible Product Use of this product may help building projects meet green building standards as set by the leadership in Energy and Environmental design (leed) Green Building Rating System. MR Credit Recycled Content MR Credit Regional Materials Data Sheet November 2013 GREENGUARd Gold SM Knauf Insulation achieved GREENGUARd Gold Certification and is verified to be formaldehyde free. GREENGUARd Certification Program SM Products are certified to GREENGUARd standards for low chemical emissions into indoor air during product usage. For more information, visit ul.com/gg. Rigid Plenum Liner with ECOSE Technology

8 Rigid Plenum Liner with ECOSE Technology Description Knauf Insulation Rigid Plenum Liner with ECOSE Technology is a heavy-density mat-faced Glass Mineral Wool board insulation bonded with ECOSE Technology. Its base board is brown with WGF facing to give the airstream a smooth, tough surface, that resists damage during installation and operation. ECOSE Technology ECOSE Technology is a revolutionary binder chemistry that makes Knauf Insulation products even more sustainable than ever. It features rapidly renewable bio-based materials rather than nonrenewable petroleum-based chemicals traditionally used in Glass Mineral Wool insulation products. ECOSE Technology reduces binder embodied energy and does not contain phenol, formaldehyde, acrylics, artificial colors or UREA. Knauf Insulation Rigid Plenum Liner with ECOSE Technology is specifically designed as an interior insulation material for heating, ventilating and air conditioning plenums and sheet metal ducts. It offers an optimum combination of efficient sound absorption, low thermal conductivity and minimal air surface friction. Features Low thermal conductivity Fire-resistant, non-corrosive Tough and resilient Knauf Insulation achieved GREENGUARD Gold Certification and is verified to be formaldehyde free. Products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. Knauf Insulation has achieved a UL Environment claim validation for over 50% post-consumer recycled glass content in our insulation products. Sustainability Carbon negative: meaning Knauf Insulation products used for thermal insulating purposes recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. Glass Mineral Wool insulation with ECOSE Technology contains three primary ingredients: Sand, one of the world s most abundant and renewable resources A minimum 60% recycled post-consumer glass content and UL Environment verification every 6 months ECOSE Technology which reduces binder embodied energy by up to 70% Benefits Energy conservation Better temperature control Lower operating costs Greatly reduces noise from fans and mechanical equipment as well as cross-talk and air movement Withstands damage from normal handling and shop abuse If necessary, can be cleaned in accordance with NAIMA s Cleaning Glass Mineral Wool Insulated Air Duct Systems Recommended Practices. Specification Compliance ASTM C 1071; Type II ASTM G 21 GREENGUARD Certified GREENGUARD GOLD SM NFPA 90A and 90B Technical Data UL/ULC Classified Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, CAN/ULC S102-M88, NFPA 255 and UL 723 Temperature Range (ASTM C 411) Up to 250 F (121 C). Max thick 3" Air Velocity (ASTM C 1071) Maximum 5000 fpm (1524 mpm) Tested to 12,500 fpm (3810 mpm) Corrosiveness (ASTM C 665) Does not accelerate corrosion on steel, copper or aluminum Corrosion (ASTM C 1617) The corrosion rate in mils/yr will not exceed that of the 1 ppm chloride solution. Water Vapor Sorption (ASTM C 1104) Less than 5% by weight Microbial Growth (ASTM C 1338) Does not promote or support the growth of mold, fungi or bacteria and Specification Guidelines Storage Inside storage is recommended. Protect stored Rigid Plenum Liner from water damage or abuse. If stored outside, stack cartons on pallets and cover adequately to prevent moisture infiltration. Fabrication and Install Knauf Insulation Rigid Plenum Liner in metal duct and plenums operating at 250 F (121 C) service temperature or less and velocities of 5000 fpm (1524 mpm) or less. Liner shall be applied with the treated surface facing toward the air stream. Mechanical fasteners shall not compress the liner more than 1/8" (3.2 mm) and shall be installed perpendicular to the airstream surface. All fasteners must meet Standard for Mechanical Fasteners-MF Adhesives which conform to ASTM C 916 shall be applied to the sheet metal with at least 90% coverage. All internal duct areas designated to be lined shall be completely covered with liner. Transverse joints shall be firmly butted together with no gaps, and coated with adhesive. All exposed leading edges shall be coated with adhesive. Mechanical fasteners shall be used to secure the rigid plenum liner and spaced in accordance with the chart and diagram to the right. Corner joints shall be overlapped so no gaps are present. Top pieces shall be supported by side pieces. All longitudinal joints shall be coated with adhesive conforming to ASTM C 916 at velocities over 2500 fpm (762 mpm). All damaged areas to the airstream surface shall be repaired with an adhesive that conforms to ASTM C 916. Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Air handling insulation used in the air stream must be discarded if exposed to water. Notes The chemical and physical properties of Knauf Insulation Rigid Plenum Liner with ECOSE Technology represent typical average values determined in accordance with accepted test methods. The data is subject to normal manufacturing and testing variations. The data is supplied as a technical service and and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. When condensation is permitted to occur between nested Rigid Plenum Duct Liner and galvanized steel panels, discoloration of the metal may occur. Check with your Knauf Insulation sales repersentative to assure information is current. Friction Loss (Inches of water per 100') Mechanical Fastener Location Velocity/fpm (meters/second) (0-12.7) ( ) A From corners of duct B From transverse end of duct liner C Across width of duct, on centers (min. 1/side) D Across length of duct, on centers (min. 1/side) Forms Available* 4" (102 mm) 3" (76 mm) 12" (305 mm) 18" (457 mm) 4" (102 mm) 3" (76 mm) 12" (305 mm) 18" (457 mm) FPM Hydraulic Diameter Velocity 10'' 16'' 24'' 32'' 40'' 72'' 100'' Sound Absorption Coefficients (ASTM C 423, Type A Mounting) Octave Band Center Frequency (cycles/sec.) Product NRC 3.0 PCF 1'' (48 kg/m 3 25 mm) 3.0 PCF 1.5'' (48 kg/m 3 38 mm) 3.0 PCF 2'' (48 kg/m 3 51 mm) Thermal Conductance C 1 and Resistance R 2 (ASTM C 177) Mean Temperature 75 F (24 C) Product Conductance C Resistance R 3.0 PCF 1''.23 (1.31) 4.3 (.76) (48 kg/m 3 25 mm) 3.0 PCF 1.5'' (48 kg/m 3 38 mm) 3.0 PCF 2'' (48 kg/m 3 51 mm) C Units: BTU ft 2 hr F.15 (.85) 6.5 (1.15).11 (.62) 8.7 (1.53) W ft 2 hr F m 2 C R Units: m 2 C) BTU W ) ( ( 1 The lower the value, the better the performance. 2 The higher the value, the better the performance. Thickness Density Width Length 1 1½ 3.0 PCF 2 24 (610 mm) 48 (1219 mm) and and 96 (2438mm) 48 (1219 mm) 36 (914 mm), 72 (1829 mm), 96 (2438 mm), 120 (3048 mm)

9 For cooling, heating or dual temperature service. Knauf Exeed Insulation LLC Mussafah ICAD1 P.O. Box 34332, Abu Dhabi, UAE Friendly Feel Duct Wrap meets the most stringent IAQ tests GREENGUARD Children & Schools and California s Section standard. Tel Fax sales@kei.ae The white facing offers exceptional durability and performance for exposed applications. LEED Eligible Product Use of this product may help building projects meet green building standards as set by the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. Credit Recycled Content Credit Regional Materials Data Sheet November 2013 Facts at a glance Fire-resistant facing Conforms to flat or irregular surfaces Excellent acoustical properties Knauf Insulation Friendly Fe el Duct Wrap with ECOSE Technology is certified for indoor air quality as a low emitting product by the GREENGUARD Environmental Institute to both the GREENGUARD Indoor Air Quality Certification Program SM and the more stringent GREENGUARD Children & Schools SM standard and is verified to be formaldehyde free. Friendly Feel Duct Wrap with ECOSE Technology ECOSE Technology is a revolutionary binder based on rapidly renewable bio-based materials rather than non-renewable petroleum-based chemicals such as phenol, formaldehyde, acrylics, artificial colors or UREA.

10 Friendly Feel Duct Wrap with ECOSE Technology Description Knauf Insulation Friendly Feel Duct Wrap with ECOSE Technology is a thermal and acoustical insulation blanket made from highly resilient Glass Mineral Wool bonded by ECOSE Technology. It is available unfaced, with a foil-scrim-kraft (FSK) jacket and with a white All Service jacket (ASJ). Vapor retarders provide a 2" (51 mm) staple flange on one edge, and the factory-applied facing assures uniform quality. ECOSE Technology ECOSE Technology is a revolutionary binder chemistry that makes Knauf Insulation products even more sustainable than ever. It features rapidly renewable bio-based materials rather than nonrenewable petroleum-based chemicals traditionally used in Glass Mineral Wool insulation products. ECOSE Technology reduces binder embodied energy and does not contain phenol, formaldehyde, acrylics, artificial colors or UREA. Knauf Insulation Friendly Feel Duct Wrap is used as external insulation on commercial or residential heating or air conditioning ducts. It is suitable for the exterior of rectangular or round sheet metal ducts and spaces or surfaces where temperature and condensation must be controlled. Features and Benefits Low k factor significantly reduces heat gain or loss when applied with proper compression Flexible Lightweight Excellent acoustical properties Tough and resilient Energy conservation, which lowers operating costs System efficiency increases; energy usage/costs decrease Conforms easily to flat or irregular surfaces Rolls allow for faster installation, lower labor costs Reduces sound transmission through the duct wall Assured condensation control when used with FSK or ASJ facings, proper installation and sealed joints, seams and penetrations Resists damage in shipment and during and after installation Knauf Insulation achieved GREENGUARD Gold Certification and is verified to be formaldehyde free. Products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. Knauf Insulation has achieved a UL Environment claim validation for over 50% post-consumer recycled glass content in our insulation products. Sustainability Carbon-negative, meaning Knauf Insulation products used for thermal insulating purposes recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. Glass Mineral Wool insulation with ECOSE Technology contains three primary ingredients: Sand, one of the world s most abundant and renewable resources A minimum 50% recycled post-consumer glass content and UL Environment verification every 6 months ECOSE Technology which reduces binder embodied energy by up to 70% Specification Compliance ASTM C unfaced; Type I, Type II, Grade lb/ft 3 Grade lb/ft 3 Grade lb/ft 3 ASTM C 553; Type I, II, III ASTM C 1136; Type II ASTM C 1290 GREENGUARD GOLD SM and verified to be formaldehyde free NFPA 90A and 90B Technical Data UL/ULC Classified FHC 25/50 (FSK, Unfaced) Unfaced and FSK wrap have a Flame Spread 25 and Smoke Developed 50 when tested in accordance with ASTM E 84, CAN/ULC S102-M88, NFPA 255 and UL 723. ASJ wrap has a Flame Spread 25 and Smoke Developed 50 when tested in accordance with ASTM E 84. Temperature Range (ASTM C 411) Faced, can be used on ducts operating up to 250 F (121 C) Unfaced, up to 350 F (177 C) Water Vapor Permeance (ASTM E 96, Procedure A) FSK and white ASJ facings have maximum water vapor permeance of.02 perms. Water Vapor Sorption (ASTM C 1104) Less than 5% by weight when tested for 96 hours at 120 F (49 C) and 95% relative humidity Corrosiveness (ASTM C 665) Does not accelerate corrosion on steel, copper or aluminum Corrosion (ASTM C 1617) The corrosion rate in mils/yr will not exceed that of the 1 ppm chloride solution. Mold Growth (ASTM C 1338) No growth Puncture Resistance (TAPPI Test T803) (Beach Units) FSK and ASJ: 25 & Specification Guidelines Storage Protect stored insulation from water damage, construction damage and other abuse. If stored outside, proper protection from weather conditions should be provided. Preparation Install Knauf Insulation Friendly Feel Duct Wrap over clean, dry sheet metal ducts. All sheet metal joints and seams must be sealed to prevent air leakage from the duct. Install Knauf Insulation Friendly Feel Duct Wrap with facing to the outside to obtain specified R-value using a maximum of 25% compression. Butt all insulation joints firmly together. Longitudinal seam of the vapor retarder must be overlapped a minimum of 2" (51 mm). A 2" (51 mm) tab is provided for the circumferential seam and must be overlapped. Where vapor retarder performance is necessary, all penetrations, joints, seams and damage to the facing should be sealed with an FSK, ASJ or foil tape or glass fabric and mastic prior to system startup. Pressure sensitive tapes should be a minimum 3" (76 mm) wide and be applied with moving pressure using an appropriate sealing tool. Staples should be outward clinch and placed approximately 6" (152 mm) on center. Closure systems should have a 25/50 F.H.C. per UL 723. For rectangular ducts over 24" (610 mm) wide, secure the insulation to the bottom side of the duct with mechanical fasteners spaced on 18" (457 mm) centers to reduce sag. Care should be taken to avoid overcompressing the insulation with the retaining washer. It is neither necessary nor desirable to adhere duct wrap to duct surfaces with adhesive. Unfaced Duct Wrap should be overlapped with a minimum of 2 (51 mm) and fastened with 4 (102 mm) to 6 (152 mm) nails or skewers placed 4 (102 mm) apart, or secured with a wire or banding system. Care must be taken to avoid damaging the duct wrap. Refer to diagram for staple stitching and butt-joint method. Installation Procedures Use the table (right inside fold) to determine stretch-outs required for the nominal thickness of insulation to limit average compression of the insulation 25% or less. Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold, it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Air handling insulation used in the air stream must be discarded if exposed to water. Notes The chemical and physical properties of Knauf Insulation Friendly Feel Duct Wrap represent typical average values determined in accordance with accepted test methods. The data is subject to normal manufacturing and testing variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. Check with your Knauf Insulation sales representative to assure information is current. Labeled Thickness P = Perimeter of duct to be installed. Stretch-Outs Installed Compressed Thickness Round Square Rectangular 1 /2" (38 mm) 1 /8" (29 mm) P+9 1 /2" (241 mm) P+8" (203 mm) P+7" (178 mm) 2" (51 mm) 1 /2" (38 mm) P+12" (305 mm) P+10" (254 mm) P+8" (203 mm) 2 3 /16" (56 mm) 1 5 /8" (42 mm) P+13" (330 mm) P+11" (279 mm) P+8 1 /2" (216 mm) 2 1 /2" (64 mm) 1 7 /8" (48 mm) P+14 1 /2" (368 mm) P+12 1 /2" (318 mm) P+9 1 /2" (241 mm) 3" (76 mm) 2 1 /4" (57 mm) P+17" (432 mm) P+14 1 /2" (368 mm) P+11 1 /2" (292 mm) Forms Available/R-Values@75 F Mean Temperature Density Thickness Width Length Facing 1½" (38 mm) 100' (30.48 m).75 PCF 2" (51 mm) 75' (22.86 m) 2 3 /16" (56 mm) 1.2 m 75' (22.86 m) (12 kg/m 3 ) 2½" (64 mm) 75' (22.86 m) FSK, ASJ 3" (76 mm) 50' (15.24 m) unfaced 1.0 PCF 1½" (38 mm) 1.2 m 100' (30.48 m) (16 kg/m 3 ) 2" (51 mm) 75' (22.86 m) 1.5 PCF 1½" (38 mm) 1.2 m 75' (22.86 m) (24 kg/m 3 ) 2" (51 mm) 50' (15.24 m) Out-Of Package R-Value Installed R-Value Duct Dimensions Condensation Control Recommended minimum install R-Values for condensation control on flat surfaces. Surface emittance : 0.2 (aged aluminum foil or galvanized sheet metal). Operating Temperature RH 45 F (7 C) Ambient Temperature ( F) 55 F (13 C) Ambient Temperature ( F) 60 F (18 C) Ambient Temperature ( F) % All Duct Wrap products PCF, 2" and greater; 1.0 PCF, 1½" and greater; 1.5 PCF, 1½" and greater Insertion Loss (Reduction of Sound Transmitted Through Duct Wall) (Sound and Vibration Design and Analysis, National Environmental Balancing Bureau, 1994) Duct Wrap Insertion Loss, db/lf of Duct Sheet Metal Nominal Thickness Nominal Density 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 12" x 12" (305 mm x 305 mm) 24 GA 1½" (38 mm).75 PCF (12 kg/m 3 ) " x 12" (610 mm x 305 mm) 24 GA 1½" (38 mm).75 PCF (12 kg/m 3 ) " x 12" (1219 mm x 305 mm) 22 GA 1½" (38 mm).75 PCF (12 kg/m 3 ) " x 24" (610 mm x 610 mm) 22 GA 1½" (38 mm).75 PCF (12 kg/m 3 ) " x 12" (610 mm x 305 mm) 26 GA 1½" (38 mm).75 PCF (12 kg/m 3 ) " x 8" (610 mm x 203 mm) 26 GA 2" (51 mm).75 PCF (12 kg/m 3 ) PCF, 2" and greater; 1.0 PCF, 2"; 1.5 PCF, 2" PCF, 2½" and greater Thermal Efficiency (ASTM C 177) 0.75 PCF 1.0 PCF 1.5 PCF Mean Temperature k k (SI) k k (SI) k k (SI) 50 F (10 C) F (24 C) F (38 C) F (52 C) F (66 C) F (80 C) F (93 C)

11 Knauf Exeed Insulation LLC Mussafah ICAD1 P.O. Box 34332, Abu Dhabi, UAE Tel Fax sales@kei.ae LEED Eligible Product Use of this product may help building projects meet green building standards as set by the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. Credit Recycled Content Credit Regional Materials Data Sheet November 2013 GREENGUARD Gold SM Knauf Insulation building insulation achieved GREENGUARD Gold Certification and is verified to be formaldehyde free. GREENGUARD Certification Program SM Products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. For more information, visit ul.com/gg. Knauf Insulation has achieved a UL Environment claim validation for over 50% post-consumer recycled glass content in our insulation products. Elevated Temperature Batt 450 and HD Blanket 450 with ECOSE Technology

12 Elevated Temperature Batt 450 and HD Blanket 450 with ECOSE Technology Description Knauf Insulation ET Batt 450 and Knauf Insulation ET HD Blanket 450 with ECOSE Technology are semi-rigid thermal insulations (1.6 pcf, 25.6 kg/m 3 ) bonded with ECOSE Technology. ECOSE Technology ECOSE Technology is a revolutionary new binder chemistry that makes Knauf Insulation products even more sustainable than ever. It features rapidly renewable bio-based materials rather than nonrenewable petroleum-based chemicals traditionally used in Glass Mineral Wool insulation products. ECOSE Technology reduces binder embodied energy and does not contain phenol, formaldehyde, acrylics, artificial colors or UREA. Knauf Insulation ET Batt 450 and Knauf Insulation ET HD Blanket 450 with ECOSE Technology are used in high-temperature marine applications, industrial furnaces, boilers, vessels and industrial ovens, where lighter-weight insulation is needed or flexible and/or semi-rigid high-temperature insulations are needed for irregular surfaces. Features and Benefits Excellent Thermal Properties Low thermal conductivity Increase system efficiency and decrease fuel usage Low-Cost Installations Lightweight and easy to handle and fabricate Flexibility makes them ideal for flat or irregular surfaces Damage Resistant More resistant to abuse than standard ET blankets Tough and resilient Resist damage in shipment and during and after installation Custom Sizes All items are available in made-to-order sizes. Indoor Air Quality Excellence The GREENGUARD Certification Program (formerly known as GREENGUARD Indoor Air Quality Certification) gives assurance that products designed for use in indoor spaces meet strict chemical emissions limits, which contribute to the creation of healthier interiors. Achieving GREENGUARD Certification gives credence to manufacturers sustainability claims, backing them with empirical scientific data from an unbiased, third-party organization. Sustainability Carbon-negative: meaning Knauf Insulation products used for thermal insulating purposes recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. Glass Mineral Wool insulation with ECOSE Technology contains three primary ingredients: Sand, one of the world s most abundant and renewable resources A minimum 60% recycled post-consumer glass content and UL Environment verification every 6 months ECOSE Technology which reduces binder embodied energy by up to 70% and total product embodied energy by up to 4%. Specification Compliance UL/ULC Classified GREENGUARD Certified GREENGUARD GOLD SM and verified to be formaldehyde free USCG 164/109/18/1 ASTM C 1139 Type I Grade 3, Type 2 Grade 3 Conforms to Marine Equipment European 1408/13 Technical Data UL/ULC Classified Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, CAN/ULC S102-M88, NFPA 90A and 90B, NFPA 255 and UL 723 Water Vapor Sorption (ASTM C 1104) 0.1% or less by volume. Temperature Limit (ASTM C 411) Up to 842 F (450 C) at a maximum recommended thickness of 6. Resists Microbial Growth (ASTM C 1338) Does not promote or support the growth of mold, fungi or bacteria. Corrosiveness (ASTM C 665) Does not accelerate corrosion on aluminum, steel or copper. Corrosion (ASTM C 1617) The corrosion rate in mills/yr will not exceed that of the 1 ppm chloride solution. and Specification Guidelines Precautions During initial heat-up to operating temperatures above 350 F (177 C), a slight odor and some smoke may be given off as a portion of the bonding material used in the insulation begins to undergo a controlled decomposition. If natural convection is not adequate in confined areas, forced ventilation should be provided in order to protect against any harmful fumes and vapors that might be generated. Storage Protect material from water damage or other abuse. Protect from welding sparks and open flame. The material may be stored outside if the packaging is not damaged. Preparation Apply the product on clean, dry surfaces. There is no heat-up cycle required for Knauf ET Batt 450 and Knauf ET HD Blanket 450. The product should be secured with welded pins or studs and covered with sheet metal. An alternate method entails covering the insulation with a metal mesh and insulating cement, canvassing and painting. Pins and studs shall be located a maximum of 4'' (102 mm) from each edge and spaced no greater than 16'' (406 mm) on center. Care should be taken to avoid over compressing the insulation with the retaining washer. For application of Knauf ET Batt 450 and Knauf ET HD Blanket 450 over 500 F (260 C), double layer application is recommended with staggered joints. When using the products at 1000 F (538 C), it is recommended that no more than 6 (152 mm) thickness should be used. For thicknesses in excess of 6, contact your Knauf Insulation sales representative. Caution Glass Mineral Wool may cause temporary skin irritation. Wear long-sleeved, loose-fitting clothing, head covering, gloves and eye protection when handling and applying material. Wash with soap and warm water after handling. Wash work clothes separately and rinse washer. A disposable mask designed for nuisance type dusts should be used where sensitivity to dust and airborne particles may cause irritation to the nose or throat. Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Notes The chemical and physical properties of Knauf ET Batt 450 and Knauf ET HD Blanket 450 with ECOSE Technology represent typical average values determined in accordance with accepted test methods. The data is subject to normal manufacturing variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. Check with your Knauf Insulation sales representative to assure information is current. Thermal Efficiency (ASTM C 177) Mean Temperature k k(si) 100 F (38 C) F (93 C) F (149 C) F (204 C) F (260 C) ET Batt 450 Forms Available Thickness Width Length 1½'' (38 mm) 2'' (51 mm) 2½'' (64 mm) 3'' (76 mm) 0.6 m or 1.2 m 1.0 m or 1.2 m 3½'' (89 mm) 4'' (102 mm) HD Blanket 450 Forms Available Thickness Width Length 1½'' (38 mm) 100' (30.5 m) 2'' (51 mm) 80' (24.4 m) 2½'' (64 mm) 70' (21.3 m) 1.2 m 3'' (76 mm) 60' (18.3 m) 3½'' (89 mm) 50' (15.2 m) 4'' (102 mm) 40' (12.2 m)

13 Knauf Exeed Insulation LLC Mussafah ICAD1 P.O. Box 34332, Abu Dhabi, UAE Tel Fax sales@kei.ae LEED Eligible Product Use of this product may help building projects meet green building standards as set by the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. MR Credit Recycled Content MR Credit Regional Materials Data Sheet November 2013 Knauf Equipment Liner M with ECOSE Technology products are certified for indoor air quality by the GREENGUARD Environmental Institute TM to both the GREENGUARD Indoor Air Quality Certification Program SM and the more stringent GREENGUARD Children & Schools SM standard and are verified to be formaldehyde free. The GREENGUARD Indoor Air Quality Certified Mark is a registered certification mark used under license through the GREENGUARD Environmental Institute. Equipment Liner M with ECOSE Technology

14 Equipment Liner M with ECOSE Technology Description Knauf Equipment Liner M with ECOSE Technology is a natural brown flexible Glass Mineral Wool blanket with WGF facing adhered to the air stream side. The product provides thermal and acoustical insulation while providing a smooth, tough air stream surface which resists damage during installation and operation. ECOSE Technology ECOSE Technology is a revolutionary binder chemistry that makes Knauf Insulation products even more sustainable than ever. It is based on rapidly renewable bio-based materials rather than non-renewable petroleum-based chemicals traditionally used in Glass Mineral Wool insulation products. ECOSE Technology reduces binder embodied energy and does not contain phenol, formaldehyde, acrylics, artificial colors or UREA. It is used to provide noise reduction and thermal insulation for equipment (air conditioning, heating) where air erosion resistance is required. The product is designed for systems operating at temperatures up to 250 F (121 C) and velocities up to 6000 fpm (1829 mpm). Features and Benefits Certified for indoor air quality as a low emitting product by The GREENGUARD Environmental Institute to both the GREENGUARD Certification Program SM and the more stringent GREENGUARD Gold SM standard. Sustainability Carbon negative: meaning Knauf insulation products used for thermal insulating purposes recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. Glass Mineral Wool insulation with ECOSE Technology contains three primary ingredients: Sand, one of the world s most abundant and renewable resources Post-consumer recycled bottle glass ECOSE Technology which reduces binder embodied energy by up to 70% Technical Data Fire Resistance Meets NFPA 90A and NFPA 90B Standards for fire safety. Temperature Range (ASTM C 411) Up to 250 F (121 C). Air Velocity (ASTM C 1071) Maximum 6000 fpm (1829 mpm). Corrosiveness (ASTM C 665) Does not accelerate corrosion on steel, copper or aluminum. Corrosion (ASTM C 1617) The corrosion rate in mils/yr will not exceed that of the 1 ppm chloride solution. Water Vapor Sorption (ASTM C 1104) Less than 3% by weight. (UL/ULC Classified) When tested in accordance with ASTM E 84, UL 723, CAN 4-S102, and NFPA-255, Knauf Equipment Liner M does not exceed 25 Flame Spread, 50 Smoke Developed Microbial Growth (ASTM C 1338, G 21) The airstream surface mat facing is treated with an EPA-registered anti-microbial agent to aid in the prevention of fungal and bacterial growth. Does not promote or support the growth of mold, fungi or bacteria. Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Air handling insulation used in the air stream must be discarded if exposed to water. Notes The chemical and physical properties of Knauf Equipment Liner M with ECOSE Technology represent typical average values determined in accordance with accepted test methods. The data is subject to normal variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these, or any other material under actual fire conditions. Check with your Knauf Insulation sales representative to assure information is current. 1.5 PCF (24 kg/m 3 ) 2.0 PCF (32 kg/m 3 ) Thermal Resistance (ASTM C 518) 75 F Mean Temperature Density Thickness R 75 F (24 C) 1.5 PCF (24 kg/m 3 ) 2.0 PCF (32 kg/m 3 ) Sound Absorption Coefficients (ASTM C 423) Type A Mounting Octave Band Center Frequency (cycles/sec) Type NRC 1'' (25 mm) ½'' (38 mm) '' (51 mm) ½'' (13 mm) '' (25 mm) ½'' (38 mm) Forms Available Density Thickness Width Length 1'' (25 mm) 100' (30.48 m) 1.5 PCF (24 kg/m 3 ) 1½'' (38 mm) 50' (15.24 m) 2'' (51 mm) 0.6 m or 1.2 m 50' (15.24 m) ½'' (13 mm) 100' (30.48 m) 2.0 PCF (32 kg/m 3 ) 1'' (25 mm) 50' (15.24 m) 1½'' (38 mm) 50' (15.24 m) 1'' (25 mm) 4.2 1½'' (38 mm) 6.0 2'' (51 mm) 8.0 ½'' (13 mm) 2.1 1'' (25 mm) 4.2 1½'' (38 mm) 6.3

15 Forms Available* Density (PCF) Thickness R-Value (R-SI) /2" (38 mm) 6.3 (1.1) 2" (51 mm) 8.3 (1.5) (26 kg/m 3 ) 3" (76 mm) 12.5 (2.2) 1" (25 mm) 4.3 (0.8) /2" (38 mm) 6.5 (1.1) 2" (51 mm) 8.7 (1.5) (36 kg/m 3 ) 3" (76 mm) 13.0 (2.3) 4" (102 mm) 17.4 (3.1) 1" (25 mm) 4.3 (0.8) /2" (38 mm) 6.5 (1.1) 2" (51 mm) 8.7 (1.5) (48 kg/m 3 ) 2 1 /2" (64 mm) 10.9 (1.9) 3" (76 mm) 13.0 (2.3) 1" (25 mm) 4.3 (0.8) /2" (38 mm) 6.5 (1.1) (68 kg/m 3 ) 2" (51 mm) 8.7 (1.5) 2 1 /2" (64 mm) 10.9 (1.9) 1" (76 mm) 4.5 (0.8) /2" (89 mm) 6.8 (1.2) (96 kg/m 3 ) 2" (102 mm) 9.1 (1.6) * Available in widths of 0.6m and 1.2m, and lengths from 1.0m to 3.0m Knauf Exeed Insulation llc Mussafah ICAd1 P.O. Box 34332, Abu dhabi, UAE Tel Fax sales@kei.ae leed Eligible Product Use of this product may help building projects meet green building standards as set by the leadership in Energy and Environmental design (leed) Green Building Rating System. Credit Recycled Content Credit Regional Materials Data Sheet November 2013 Knauf Insulation Board with ECOSE Technology products are certified for indoor air quality as low emitting products by the GREENGUARd Environmental Institute to both the GREENGUARd Indoor Air Quality Certification Program SM and the more stringent GREENGUARd Children & Schools SM standard and are verified to be formaldehyde free. The GREENGUARd Indoor Air Quality Certified Mark is a registered certification mark used under license through the GREENGUARd Environmental Institute. Insulation Board with ECOSE Technology

16 Insulation Board with ECOSE Technology Description Knauf Insulation Board with ECOSE Technology is a thermal and acoustical insulation product bonded with ECOSE Technology. It is available plain or with a factory-applied FSK facing, or all-service jacket plus (ASJ+). ASJ+ is the newest generation all-service jacket composed of aluminum foil, reinforced with a glass scrim bonded to a kraft paper interleaving with an outer film layer leaving no paper exposed. The ASJ+ provides a Professional finished appearance dimple and wrinkle resistant Cleanable with a wet cloth and soapy water Moisture resistant to intermittent, short duration liquid water exposure, such as precipitation during construction phase ASJ+ has substantially less degradation and discoloration when exposed to UV. ASJ+ meets ASTM C1136 Type I, II, III, IV, and meets VIII based on the 85% better puncture resistance of ASJ+ (Mullen Burst). Knauf Insulation Board with ECOSE Technology is a versatile product for thermal and acoustical applications such as: heating and air conditioning ducts, power and process equipment, boiler and stack installations, metal and masonry walls, wall and roof panel systems, curtain wall assemblies and cavity walls. Features and Benefits Energy Conservation Excellent thermal efficiency results in lower operating costs Low-Cost Installation Lightweight, easy to handle and fabricate Fast, easy installation lowers labor costs Indoor Air Quality Excellence Knauf Insulation achieved GREENGUARD GOLD Certification and is verified to be formaldehyde free. Products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. Knauf Insulation has achieved a UL Environment claim validation for over 50% post-consumer recycled glass content in our insulation products. Sustainability Carbon negative: meaning Knauf insulation products used for thermal insulating purposes recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. Glass Mineral Wool insulation with ECOSE Technology contains three primary ingredients: Sand, one of the world s most abundant and renewable resources A minimum 50% recycled post-consumer glass content and UL Environment verification every 6 months ECOSE Technology which reduces binder embodied energy by up to 70% It is anticipated to reduce its Global Warming Potential (GWP) by approximately 4%, a significant reduction in our carbon footprint Noise Reduction Excellent acoustical properties effectively reduce noise Appearance FSK and ASJ+ vapor-retardant facings provide a neat finished appearance Specification Compliance UL/ULC Classified (FSK, ASJ+) ASTM C 612 Type IA (1.6, 2.25, 3.0, 4.25, 6.0 pcf) (26, 36, 48, 68, 96 kg/m3) Type IB (3.0, 4.25, 6.0 pcf) (48, 68, 96 kg/m3) ASTM C 795 ASTM C 1136 (facings) Type I, II, III, IV (ASJ) Type II, IV (FSK) Form A, Class 1 (1.6, 2.25, 3.0, 4.25, 6.0 pcf) (26, 36, 48, 68, 96 kg/m3) Form A, Class 2 (3.0, 4.25, 6.0 pcf) (48, 68, 96 kg/m3) NFPA 90A and 90B GREENGUARD GOLD and verified to be formaldehyde free. This product complies with Oregon Revised Statute and contains less than 0.10% decabromdiphenyl ether (DecaBDE) by mass. Technical Data (UL Classified) Unfaced or composite (insulation, facing and adhesive) does not exceed 25 Flame Spread, 50 Smoke Developed when tested in acordance with ASTM E 84, CAN/ULC S102, NFPA 90A and 90B, NFPA 255 and UL 723 Temperature Range (ASTM C 411) Operating temperatures from 0 F to 450 F (-18 C to 232 C) Corrosiveness (ASTM C 665) Will not accelerate corrosion of aluminum, steel or copper Corrosion (ASTM C 1617) The corrosion rate in mils/yr will not exceed that of the 1 ppm chloride solution. Puncture Resistance (TAPPI Test T803) (Beach Units) FSK facing: 25 ASJ facing: 55 ASJ+ facing: 120 Water Vapor Transmission (ASTM E 96, Procedure A) FSK and ASJ+ vapor retarders have a maximum vapor transmission rate of.02 perms. Water Vapor Sorption (ASTM C 1104) Less than 5% by weight when exposed to air at 120 F (49 C) and 95% humidity for 96 hours Shrinkage (ASTM C 356) Less than 0.3% linear shrinkage Resists Microbial Growth (ASTM C 1338, G21) Does not promote or support the growth of mold, fungi or bacteria & Specification Guidelines Storage Protect material from water damage or other abuse. Cartons are not designed for outside storage. Vacuum packaged material can be stored outside if care is taken not to puncture the poly bag. Preparation Apply the product on clean, dry surfaces. Metal ducts must be sealed before application. Prescore rigid insulation board where necessary to conform to curved surfaces. GENERAL: All insulation joints must be firmly butted. Insulation can be secured with adhesive, mechanical fasteners or banded. Minimum compression is to be used to assure firm fit and still maintain thermal performance. Vapor retarders should overlap a minimum of 2" (51 mm) at all seams, and be sealed with appropriate pressure sensitive tape or mastic. When applying pressure sensitive tapes, the tape must be firmly rubbed with a proper sealing tool to make sure the closure is secure. Follow tape manufacturer s recommendations. Fasteners shall be located a maximum of 3" (76 mm) from each edge and spaced no greater than 12" (457 mm) on center. Where vapor retarder performance is necessary, all penetrations and facing damage shall be repaired with tapes or mastic with a minimum of 2" (51 mm) overlap. Tapes should be applied using a sealing tool and moving pressure. Use on ducts, plenums, vessels, tanks and equipment operating at tem peratures of 450 F (232 C) or less. Tapes and mastics (dry) should have a UL 723 rating of 25 flame spread, 50 smoke developed. DUCTS AND PLENUMS: Use of 3.0 pcf (48 kg/m3) insulation board in concealed areas is recommended. Use of 6.0 pcf (96 kg/m3) insulation board in exposed areas and outdoor applications is recommended. Insulation Board is not designed to be exposed to the airstream. VESSELS, TANKS AND EQUIPMENT: For irregular surfaces, use 1.6 pcf (26 kg/m3) insulation board and band with minimum compression. For outdoor application, Knauf Insulation Board must be covered with appropriate jacketing, mastic or other vapor retarder. All exposed surfaces must be protected. Apply jacketing, mastics and other vapor retarders in accordance with manufacturer s instructions. Precaution During initial heat-up to operating temperatures above 350 F (177 C), a slight odor and some smoke may be given off as a portion of the bonding material used in the insulation begins to undergo a controlled decomposition. If natural convection is not adequate in confined areas, forced ventilation should be provided in order to protect against any harmful fumes and vapors that might be generated. Caution Glass Mineral Wool may cause temporary skin irritation. Wear long-sleeved, loose-fitting clothing, head covering, gloves and eye protection when handling and applying material. Wash with soap and warm water after handling. Wash work clothes separately and rinse washer. A disposable mask designed for nuisance type dusts should be used where sensitivity to dust and airborne particles may cause irritation to the nose or throat. Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. ECOSE Technology ECOSE Technology is a revolutionary binder chemistry that makes Knauf Insulation products even more sustainable than ever. It features rapidly renewable bio-based materials rather than nonrenewable petroleum-based chemicals traditionally used in fiberglass insulation products. ECOSE Technology reduces binder embodied energy and contains no phenol, formaldehyde, acrylics, artificial colors or UREA. Notes The chemical and physical properties of Knauf Insulation Board with ECOSE Technology represent typical average values determined in accordance with accepted test methods. The data is subject to normal manufacturing variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. Check with your Knauf Insulation sales representative to assure information is current. Thermal Efficiency (ASTM C 177) 1.6 PCF 3.0 PCF 6.0 PCF Mean Temperature k k(si) k k(si) k k(si) 75 F (24 C) F (38 C) F (93 C) F (149 C) Type 1.6 PCF (26 kg/m 3 ) 2.25 PCF (36 kg/m 3 ) 3.0 PCF (48 kg/m 3 ) 4.25 PCF (68 kg/m 3 ) 6.0 PCF (96 kg/m 3 ) Sound Absorption Coefficients (ASTM C 423, Type A Mounting) Octave Band Center Frequency (cycles/sec.) Facing Thickness NRC 1½" (38 mm) Plain 2" (51 mm) ½" (64 mm) " (76 mm) " (25 mm) Plain 1½" (38 mm) " (51 mm) FSK 1" (25 mm) " (51 mm) " (25 mm) ½" (38 mm) Plain 2" (51 mm) " (76 mm) " (102 mm) " (25 mm) FSK 1½" (38 mm) " (51 mm) " (25 mm) ASJ 1½" (38 mm) " (51 mm) Plain 1" (25 mm) ASJ 2½" (64 mm) " (25 mm) Plain 1½" (38 mm) " (51 mm) " (25 mm) FSK 1½" (38 mm) " (51 mm) ASJ 1½" (38 mm) " (51 mm)

17 Knauf Exeed Insulation LLC Mussafah ICAD1 P.O. Box 34332, Abu Dhabi, UAE Tel Fax sales@kei.ae LEED Eligible Product Use of this product may help building projects meet green building standards as set by the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. Credit Recycled Content Credit Regional Materials Data Sheet November 2013 Knauf Metal Building Insulation with ECOSE Technology products are certified for indoor air quality as a low emitting product by The GREENGUARD Environmental Institute to both the GREENGUARD Indoor Air Quality Certification Program SM and the more stringent GREENGUARD Children & Schools standard and are verified to be formaldehyde free. The GREENGUARD INDOOR AIR QUALITY CERTIFIED Mark is a registered certification mark used under license through the GREENGUARD Environmental Institute. Metal Building Insulation with ECOSE Technology

18 Metal Building Insulation with ECOSE Technology Description Knauf Insulation Metal Building Insulation with ECOSE Technology is a resilient, flexible unfaced blanket insulation made from Glass Mineral Wool bonded by thermosetting resin. The blanket is suitable for application of facings and has sufficient tensile and bond strength for normal handling by the laminator and contractor. The blanket may also be used unfaced as additional insulation to fill voids in walls and roofs of metal buildings. ECOSE Technology ECOSE Technology is a revolutionary binder chemistry that makes Knauf Insulation products even more sustainable than ever. It features rapidly renewable bio-based materials rather than nonrenewable petroleum-based chemicals traditionally used in Glass Mineral Wool insulation products. ECOSE Technology reduces binder embodied energy and does not contain phenol, formaldehyde, acrylics, artificial colors or UREA. When Knauf Insulation Metal Building Insulation is faced with a suitable vapor retarder, it can be installed in exterior wall and roof surfaces of preengineered buildings. The product may be used unfaced to fill voids in walls and roof cavities of pre-engineered buildings. Features Low thermal conductivity Superior acoustical performance Fire-resistant, non-corrosive, tough and resilient Certified for indoor air quality as a low emitting product by The GREENGUARD Environmental Institute to both the GREENGUARD Indoor Air Quality Certification Program SM and the more stringent GREENGUARD Children & Schools standard and is verified to be formaldehyde free. Sustainability Carbon negative: meaning Knauf Insulation products used for thermal insulating purposes recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. Glass Mineral Wool insulation with ECOSE Technology contains three primary ingredients: Sand, one of the world s most abundant and renewable resources 60% recycled post-consumer glass content and ULE verification every 6 months ECOSE Technology which reduces binder embodied energy by up to 70% Benefits Energy conservation Better temperature control Lower operating costs Noise control Withstands damage from normal handling and shop abuse Condensation control Technical Data Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, NFPA-255 and UL 723. Odor (ASTM C 1304) No objectionable odor emission. Water Vapor Sorption (ASTM C 1104) Less than 0.2% by volume or 5% by weight. Corrosiveness (ASTM C 665) Does not accelerate corrosion on steel, copper or aluminum. Corrosion (ASTM C 1617) The corrosion rate in mils/yr will not exceed that of the 1 ppm chloride solution. Resistance to Microbial Growth (ASTM C 1338) Does not promote microbial growth. Noncombustibility (ASTM E 136) Noncombustible. Sound Absorption Coefficients (ASTM C 423, Type A Mounting) ¹/ 3 Octave Band Center Frequency (cycles/sec.) NRC 3'' '' '' Forms Available Thickness Width Length 3¼'' (83 mm) 100' (30.48 m) 36''-60'' ( mm) 3½'' (89 mm) 100' (30.48 m) 72''-96'' ( mm) 4¼'' (108 mm) 75' (22.86 m) 5'' (127 mm) 72''-96'' ( mm) 50' (15.24 m) 6'' (152 mm) 50' (15.24 m) 36''-60'' ( mm) 8'' (203 mm) 40' (12.19 m) 72''-96'' ( mm) 9¼'' (235 mm) 25' (7.62 m) All products meet NAIMA (REV. 2000) Specification Compliance ASTM C 553 Type I, II ASTM C 991 Type I GREENGUARD Children & Schools Certified SM and verified to be formaldehyde free HH-I-558C Form B, Class 6 NAIMA Standard (REV.2000) ASTM E 136 Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Air handling insulation used in the air stream must be discarded if exposed to water. R-Value (ASTM C 518) Mean Temperature 75 F Thickness R-Value 3¼'' 10 3½'' 11 4¼'' 13 5'' 16 6'' 19 8'' 25 9¼'' 30 Notes The chemical and physical properties of Knauf Insulation Metal Building Insulation represent typical average values determined in accordance with accepted test methods. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions.

19 Knauf Exeed Insulation llc Mussafah ICAd1 P.O. Box 34332, Abu dhabi, UAE Tel Fax sales@kei.ae leed Eligible Product Use of this product may help building projects meet green building standards as set by the leadership in Energy and Environmental design (leed) Green Building Rating System. Credit Recycled Content Credit Regional Materials Data Sheet November 2013 Pipe & Tank Insulation with ECOSE Technology

20 Pipe & Tank Insulation with ECOSE Technology Description Knauf Insulation Pipe and Tank Insulation with ECOSE Technology is a semi-rigid Glass Mineral Wool board in roll form faced with a factory applied FSK or ASJ vapor retarder or a glass mat facing. The glass mineral wool is adhered perpendicular to the jacketing, for flexibility and easy installation. ECOSE Technology ECOSE Technology is a revolutionary binder based on rapidly renewable bio-based materials rather than nonrenewable petroleum-based chemicals such as phenol, formaldehyde or acrylics. ECOSE Technology reduces Knauf binder embodied energy and contains no phenol, formaldehyde, acrylics, artificial colors or UREA found in traditional Glass Mineral Wool insulation. Knauf Pipe and Tank Insulation with ECOSE Technology is typically used on tanks, vessels and large-diameter pipes. It can be used for any curved or irregular surfaces that require finished characteristics of rigid fiber glass insulation. Features and Benefits Excellent Thermal Properties Temperature ratings to 850 F (454 C). Low-Cost Installation Flexible. Easy to handle and fabricate. Inventory Savings No need to stock multiple sizes. Various thicknesses available to meet all your pipe and tank insulation needs. Resists Damage Tough and durable. Resists damage in shipment, during and after installation. Sustainability Carbon-negative - meaning: Knauf Insulation products used for thermal insulating purposes recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. Glass Mineral Wool insulation with ECOSE Technology contains three primary ingredients: Sand, one of the world s most abundant and renewable resources A minimum 60% recycled post-consumer glass content and UL Environment verification every 6 months ECOSE Technology which reduces binder embodied energy by up to 70% Specification Compliance ASTM C 795 ASTM C 1136 Type I, II, III, IV (ASJ) Type II, IV (FSK) ASTM C 1393, Category 1 HH-B-100B (jackets) Type I and II (ASJ) Type II (FSK) HH-I-558C; Form A, Class 3 This product complies with Oregon Revised Statue and contains less than 0.10% decabromdiphenyl ether (DecaBDE) by mass. Technical Data Temperature Range (ASTM C 411) Operating temperature to 850 F (454 C). Compressive Strength (ASTM C 165) Not less than 150 PSF (7.18 kpa) at 10% deformation for 2" (51 mm) thickness. Not less than 275 PSF (13.2 kpa) at 10% deformation for 3" (76 mm). Water Vapor Transmission (ASTM E 96, Procedure A) Both FSK and ASJ vapor retarders have a maximum vapor transmission rate of.02 perms. Puncture Resistance (TAPPI Test T803) (Beach Units) FSK Facing: 25 ASJ facing: 50 Resists Microbial Growth Does not promote the growth of fungi or bacteria. Will not rot. Will not sustain vermin. Corrosiveness (ASTM C 665) Does not accelerate corrosion on steel. Corrosion (ASTM C 1617) The corrosion rate in mils/yr will not exceed that of the 1 ppm chloride solution. Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, CAN/ULC S102-M88, NFA 90A and 90B, NFPA 255 and UL723. Linear Shrinkage (ASTM C 356) Negligible. & Specification Guidelines Precautions ASJ and FSK jackets should not be used if outer-surface temperature exceeds150 F (66 C). During initial heat-up to operating temperatures above 350 F (177 C), a slight odor and some smoke may be given off as a portion of the bonding material used in the insulation begins to undergo a controlled decomposition. If natural convection is not adequate in confined areas, forced ventilation should be provided in order to protect against any harmful fumes and vapors that might be generated. Care must also be taken when using sealants, solvents or flammable adhesive during installation. Storage Protect stored insulation from water damage or other abuse. Protect from welding sparks and open flame. Cartons are not designed for outside storage. Preparation Apply Knauf Insulation Pipe and Tank Insulation on clean, dry surfaces. For easy installation of Knauf Insulation Pipe and Tank Insulation simply follow these guidelines. Refer to the Stretch-out Chart (right) to find the appropriate length to cut for the specific pipe size. Be sure to add an additional 2" (51 mm) to 4" (102 mm) for your staple flap. Cut your stretch-out length and wrap the material around the iron pipe to ensure the proper fit. Staple the lap on 3" (76 mm) centers with outward clinching staples. Butt edges shall be firmly secured, and butt strips matching the jacket shall be applied at each joint. Caution Glass Mineral Wool may cause temporary skin irritation. Wear long-sleeved, loose-fitting clothing, head covering, gloves and eye protection when handling and applying material. Wash with soap and warm water after handling. Wash work clothes separately and rinse washer. A disposable mask designed for nuisance type dusts should be used where sensitivity to dust and airborne particles may cause irritation to the nose or throat. Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Notes The chemical and physical properties of Knauf Pipe and Tank Insulation with ECOSE Technology represent typical average values determined in accordance with accepted test methods. The data is subject to normal manufacturing variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. Check with your Knauf Insulation sales representative to assure information is current. Stretch-Outs Nominal Iron Pipe Thickness Iron Pipe Size Outside Diameter 1" (25 mm) 1 1 /2" (38 mm) 2" (51 mm) 3" (76 mm) 10" (254 mm) 10 3 /4" (273 mm) 40 1 /8" (1019 mm) 43 1 /4" (1099 mm) 46 3 /8" (1178 mm) 52 5 /8" (1337 mm) 12" (305 mm) 12 3 /4" (324 mm) 46 3 /8" (1178 mm) 49 1 /2" (1257 mm) 52 3 /4" (1340 mm) 59" (1499 mm) 14" (356 mm) 14" (356 mm) 50 3 /8" (1280 mm) 53 1 /2" (1359 mm) 56 5 /8" (1438 mm) 62 7 /8" (1597 mm) 16" (406 mm) 16" (406 mm) 56 5 /8" (1438 mm) 59 3 /4" (1518 mm) 62 7 /8" (1597 mm) 69 1 /8" (1756 mm) 18" (457 mm) 18" (457 mm) 62 7 /8" (1597 mm) 66" (1676 mm) 69 1 /8" (1756 mm) 75 1 /2" (1918 mm) 20" (508 mm) 20" (508 mm) 69 1 /8" (1756 mm) 72 3 /8" (1838 mm) 75 1 /2" (1918 mm) 81 3 /4" (2076 mm) 22" (559 mm) 22" (559 mm) 75 1 /2" (1918 mm) 78 5 /8" (1997 mm) 81 3 /4" (2076 mm) 88" (2235 mm) 24" (610 mm) 24" (610 mm) 81 3 /4" (2076 mm) 84 7 /8" (2156 mm) 88" (2235 mm) 94 3 /8" (2397 mm) 26" (660 mm) 26" (660 mm) 88" (2235 mm) 91 1 /8" (2315 mm) 94 3 /8" (2397 mm) /8" (2556 mm) 28" (711 mm) 28" (711 mm) 94 3 /8" (2397 mm) 97 1 /2" (2477 mm) /8" (2556 mm) /8" (2715 mm) 30" (762 mm) 30" (762 mm) /8" (2556 mm) /4" (2635 mm) /8" (2715 mm) /8" (2873 mm) 32" (813 mm) 32" (813 mm) /8" (2715 mm) 110" (2794 mm) /8" (2873 mm) /2" (3035 mm) 34" (864 mm) 34" (864 mm) /8" (2873 mm) /4" (2953 mm) /2" (3035 mm) /4" (3194 mm) 36" (914 mm) 36" (914 mm) /2" (3035 mm) /8" (3115 mm) /4" (3194 mm) 132" (3353 mm) 38" (965 mm) 38" (965 mm) /4" (3194 mm) /8" (3273 mm) 132" (3353 mm) /4" (3512 mm) 40" (1016 mm) 40" (1016 mm) 132" (3353 mm) /8" (3432 mm) /4" (3512 mm) /8" (3673 mm) 42" (1067 mm) 42" (1067 mm) /4" (3512 mm) /2" (3594 mm) /8" (3673 mm) /8" (3832 mm) * Additional 2" (51 mm) to 4" (102 mm) should be added for lap. Thermal Efficiency (ASTM C 177) Mean Temperature k k (Si) 100 F 38 C F 93 C F 149 C F 204 C F 260 C Forms Available Thickness Width Length 1" (25 mm) 48' (14.63 m) 1½" (38 mm) 32' (9.75 m) 1200 mm 2" (51 mm) 24' (7.32 m) 3" (76 mm) 16' (4.88 m) Other lengths also available as per customer requirement

21 Knauf Exeed Insulation LLC Mussafah ICAD1 P.O. Box 34332, Abu Dhabi, UAE Tel Fax sales@kei.ae LEED Eligible Product Use of this product may help building projects meet green building standards as set by the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. MR Credit Recycled Content MR Credit Regional Materials Data Sheet November 2013 Knauf Black Acoustical Insulation with ECOSE Technology is certified for indoor air quality as a low emitting product by the GREENGUARD Environmental Institute to both the GREENGUARD Indoor Air Quality Certification Program SM and the more stringent GREENGUARD Children & Schools SM standard and is verified to be formaldehyde free. The GREENGUARD Indoor Air Quality Certified Mark is a registered certification mark used under license through the GREENGUARD Environmental Institute. Black Acoustical Insulation with ECOSE Technology

22 Black Acoustical Insulation with ECOSE Technology Wall and Ceiling Liner M with ECOSE Technology Knauf Insulation Wall and Ceiling Liner M with ECOSE Technology is a brown flexible Glass Mineral Wool blanket with WGF facing adhered to one surface. It provides thermal and acoustical insulation and a visual barrier. Its smooth, tough surface resists damage during installation. Knauf Insulation Wall and Ceiling Liner M with ECOSE Technology is designed for use as an acoustical and visual barrier for walls and ceilings where a black surface is required. It is primarily used in theaters, sound studios, public concourses and other areas where acoustical treatment is needed. It is intended to be mechanically fastened to walls and covered with fabric or draping, or suspended above linear metal Black Acoustical Board with ECOSE Technology Knauf Insulation Black Acoustical Board with ECOSE Technology is a heavy density Glass Mineral Wool board insulation bonded with ECOSE Technology. The base board is brown with WGF applied to provide a smooth, tough finish. Knauf Insulation Black Acoustical Board with ECOSE Technology is designed for use as acoustical insulation and/or a visual barrier on walls and ceilings, where system design requires a rigid product and where additional strength and abuse resistance are required. The black surface provides a visual barrier with an aesthetic appearance, in both wall and ceiling applications. The product is typically used where framing members are not present. Acoustical Barrier Reduces airborne sound transmission. Significantly improves STC ratings of wall configurations. Indoor Air Quality Certified for indoor air quality as a low emitting product by UL to both the GREENGUARD standard and the more stringent GREENGUARD Gold standard. and metal pan ceiling systems to serve as both a visual and acoustical treatment. Reduces airborne sound Significantly improves STC ratings of wall configurations Certified for indoor air quality as a low emitting product by UL to both the GREENGUARD Certification Program SM and the more stringent GREENGUARD Gold standard. Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, CAN/ULC S102-M88, NFPA 255 and UL 723 Technical Data (UL/ULC Listed) Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, CAN/ULC S102-M88, NFPA 255 and UL 723. Service Temperature (ASTM C 411) Maximum 250 F (121 C). Microbial Growth (ASTM C 1338, G 21, G 22) Does not support microbial growth. Water Vapor Sorption (ASTM C 1104) Less than 3% by weight. Air Velocity (ASTM C 1071) Maximum 4000 fpm (1219 mpm) Packaging Knauf Insulation Black Acoustical Board with ECOSE Technology is packaged in cartons that offer excellent protection from abuse, dust and moisture. Cartons are unitized for easy handling and storage. Maximum 250 F (121 C) Does not support microbial growth Less than 3% by weight Maximum 6000 fpm (1829 mpm) Knauf Insulation Wall and Ceiling Liner M with ECOSE Technology is packaged in a strong, white poly sleeve that offers excellent protection from abuse, dust and moisture. Notes The chemical and physical properties of Knauf Insulation Black Acoustical Insulation with ECOSE Technology represent typical average values determined in accordance with accepted test methods. The data is subject to normal manufacturing variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. Check with your Knauf Insulation sales representative to assure information is current. ECOSE Technology ECOSE Technology is a revolutionary binder chemistry that makes Knauf Insulation products even more sustainable than ever. It features rapidly renewable bio-based materials rather than non-renewable petroleum-based chemicals traditionally used in Glass Mineral Wool insulation products. ECOSE Technology reduces binder embodied energy and does not contain phenol, formaldehyde, acrylics, artificial colors or UREA. Sustainability Knauf Insulation products used for thermal insulating purposes recover the energy that it took to make them in just hours or days depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place (carbon negative). Glass Mineral Wool with ECOSE Technology contains three primary ingredients: Sand, one of the world s most abundant resources More than 60% recycled post-consumer glass content verified every 6 months by UL Environment Our green chemistry initiative ECOSE Technology, which reduces binder embodied energy by up to 70% Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Wall and Ceiling Liner M Noise Reduction Coefficients (ASTM C 423, Type A Mounting) Density Thickness NRC 1" (25 mm) PCF (16 kg/m3) 1½" (38 mm).80 2" (51 mm).85 ½" (13 mm) PCF 1" (25 mm).70 (24 kg/m3) 1½" (38 mm).80 2" (51 mm) PCF ½" (13 mm).45 (32 kg/m3) 1" (25 mm).70 Black Acoustical Board Sound Absorption Coefficients (ASTM C 423, Type A Mounting) Octave Band Center Frequency (cycles/sec.) Density Thickness NRC 2.25 PCF 2" (25 mm) (36 kg/m3) 1" (51 mm) PCF (48 kg/m3) 1½" (76 mm) " (25 mm) Wall and Ceiling Liner M Forms Available* Density Thickness R-Value Width Length 1" (25 mm) ' (30.48 m) 1.0 PCF (16 kg/m3) 1½" (38 mm) ' (15.24 m) 2" (51 mm) ' (15.24 m) ½" (13 mm) ' (30.48 m) 0.6 m 1.5 PCF 1" (25 mm) 4.2 or 100' (30.48 m) (24 kg/m3) 1.2 m 1½" (38 mm) ' (15.24 m) 2" (51 mm) ' (15.24 m) 2.0 PCF ½" (13 mm) ' (30.48 m) (32 kg/m3) 1" (25 mm) ' (15.24 m) Black Acoustical Board Forms Available* Density Thickness R-Value Width Length 2.25 PCF (36 kg/m3) 3.0 PCF (48 kg/m3) 2" 1" (51 mm) (25 mm) m or 1.2 m 48" 48" (1219 mm) (1219 mm) 1½" (38 mm) " (1219 mm) 2" (51 mm) " (1219 mm) * Some products listed may be custom products. All custom product requests require approval from Knauf Insulation, regardless of whether the product has previously been produced. Special pricing and minimum order quantities will apply.

23 Knauf Exeed Insulation llc Mussafah ICAd1 P.O. Box 34332, Abu dhabi, UAE Tel Fax sales@kei.ae leed Eligible Product Use of this product may help building projects meet green building standards as set by the leadership in Energy and Environmental design (leed) Green Building Rating System. Credit Recycled Content Credit Regional Materials Data Sheet November 2013 Knauf KB Blanket with ECOSE Technology products are certified for indoor air quality as low emitting products by The GREENGUARd Environmental Institute to both the GREENGUARd Certification Program SM and the more stringent GREENGUARd Children and Schools SM standard and are verified to be formaldehyde free. The GREENGUARd INdOOR AIR QUAlITY CERTIFIEd Mark is a registered certification mark used under license through the GREENGUARd Environmental Institute. KB Blanket Insulation with ECOSE Technology

24 KB Blanket Insulation with ECOSE Technology Description Knauf KB Blanket Insulation is a lightweight blanket of Glass Mineral Wool bonded with ECOSE Technology. The products listed are manufactured single layer. However, some items with 24" and 48" widths can also be manufactured double layer. KB Blanket is used as thermal and/or acoustical insulation for appliance, equipment, acoustical, industrial, commercial and marine applications up to 650 F (343 C). ECOSE Technology ECOSE Technology is a revolutionary new binder chemistry that makes Knauf Insulation products even more sustainable than ever. It is based on rapidly renewable bio-based materials rather than non-renewable petroleum-based chemicals traditionally used in Glass Mineral Wool insulation products. ECOSE Technology reduces binder embodied energy and does not contain phenol, formaldehyde, acrylics, artificial colors or UREA. Features and Benefits Sustainability Carbon-negative - meaning: Knauf insulation products used for thermal insulating purposes recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. Glass Mineral Wool insulation with ECOSE Technology contains three primary ingredients: Sand, one of the world s most abundant and renewable resources Post-consumer recycled bottle glass ECOSE Technology which reduces binder embodied energy by up to 70% Indoor Air Quality Certified for indoor air quality as a low emitting product by The GREENGUARD Environmental Institute to both the GREENGUARD Certification Program SM and the more stringent GREENGUARD Children and Schools SM standard. Specification Compliance ASTM C 553; Types I, II and III ASTM C 795 GREENGUARD Environmental Institute Technical Data (UL Classified) When tested in accordance with ASTM E 84, UL 723, Knauf KB Blanket Insulation does not exceed 25 Flame Spread, 50 Smoke Developed. Maximum Service Temperature (ASTM C 411) Knauf KB Blanket Insulation is designed for applications to a maximum operating temperture of 650 F (343 C). Odor (ASTM C 665) Not objectionable. Resistance to Microbial Growth (ASTM C 1338) No growth. Water Vapor Sorption (ASTM C 1104) Corrosion (ASTM C 1617) The corrosion rate in mils/yr will not exceed that of the 1 ppm chloride solution. Availability KB Blanket Insulation is made-to-order and is available in rolls. For your requirements not listed, contact your Knauf Insulation sales representative. Packaging KB Blanket Insulation is placed in a poly bag, vacuum packaged, and slipped into a poly sleeve. The end of the tube is closed with a plastic tie. Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Air handling insulation used in the air stream must be discarded if exposed to water. Notes The chemical and physical properties of Knauf KB Blanket Insulation represent typical average values determined in accordance with accepted test methods. The data is subject to normal variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread rating are not intended to reflect hazards presented by these, or any other material under actual fire conditions. Check with your Knauf Insulation sales representative to assure information is current. Thermal Conductivity (ASTM C 75 F Mean Temperature Density Thermal Conductivity (BTU-in. ft 2 F).75 PCF (12 kg/m 3 ) PCF (16 kg/m 3 ) PCF (24 kg/m 3 ) PCF (32 kg/m 3 ) PCF (40 kg/m 3 ) 0.23 Sound Absorption Coefficients (ASTM C 423, Type A Mounting) Density Thickness NRC.75 PCF (12 kg/m 3 ) 1½'' (38 mm) PCF (16 kg/m 3 ) 1'' (25 mm) PCF (32 kg/m 3 ) ¾'' (19 mm) PCF (40 kg/m 3 ) ½'' (13 mm) 0.60 Forms Available Density Thickness Width Length 1 1½'' (38 mm) 150' (46.08 m) 0.75 PCF (12 kg/m 3 ) 2'' (51 mm) 100' (30.48 m) 1'' (25 mm) 150' (46.08 m) 1.0 PCF (16 kg/m 3 ) 1½'' (38 mm) 100' (30.48 m) 2'' (51 mm) 75' (22.86 m) ¾'' (19 mm) 150' (46.08 m) 0.6m 1.2m 1.5 PCF (24 kg/m 3 ) 1'' (25 mm) 100' (30.48 m) 1½'' (38 mm) 75' (22.86 m) ½'' (13 mm) 150' (46.08 m) 2.0 PCF (32 kg/m 3 ) ¾'' (19 mm) 100' (30.48 m) 1'' (25 mm) 75' (22.86 m) 2.5 PCF (40 kg/m 3 ) ½'' (13 mm) 125' (38.10 m) 1 Lengths made to your specification are also available. Less than 3% by weight. Corrosiveness (ASTM C 665) Does not accelerate corrosion on steel, copper or aluminum.

25 Facts at a glance The Knauf Insulation rotary manufacturing process produces insulation with concentric inside diameters and consistent wall thicknesses. ASJ+ is cleanable with a wet cloth and soapy water. ASJ ASJ+ Knauf Exeed Insulation llc Mussafah ICAD1 P.O. Box 34332, Abu Dhabi, UAE Tel ECOSE Pipe offers an extended temperature range for all applications from 0 to 840 F. ASJ+ is moisture resistant to intermittent, short duration liquid water exposure, such as precipitation during construction phase. ECOSE Pipe Insulation with ASJ+ is not intended for unprotected outdoor use. Fax sales@kei.ae SSL+ Advanced Closure System creates a strong and lasting bond. ASJ ASJ+ ASJ+ will provide a professional finished appearance dimple and wrinkle resistant. Knauf Insulation s wind-up forming mandrel process prevents gaps and inconsistent densities, while making it easy to cleanly notch out sections. Size, wall thickness and Proto 25/50 rated PVC fitting cover identification are printed on the jacket. leed Eligible Product Use of this product may help building projects meet green building standards as set by the leadership in Energy and Environmental Design (leed) Green Building Rating System. MR Credit Recycled Content MR Credit Regional Materials Data Sheet November 2013 ECOSE Technology bio-based binder eliminates non-renewable petroleum-based ingredients. No formaldehyde, no phenol, no acrylics or UREA ECOSE contains a minimum 60% post-consumer recycled bottle glass. ASJ ASJ+ Durability: UV light and puncture resistance. ASJ+ meets ASTM C 1136 Type I, II, III, IV and meets VIII based on the 75% better puncture resistance (Mullen Burst). ASJ+ has substantially less degradation and discoloration after exposure to UV light than traditional ASJ. ECOSE Pipe Insulation with ASJ+ is not intended for unprotected outdoor use. Knauf Insulation ECOSE Pipe Insulation with ECOSE Technology products are certified for indoor air quality as low emitting products by the GREENGUARD Environmental Institute to both the GREENGUARD Indoor Air Quality Certification Program SM and the more stringent GREENGUARD Children & Schools SM standard and are verified to be formaldehyde free. The GREENGUARD Indoor Air Quality Certified Mark is a registered certification mark used under license through the GREENGUARD Environmental Institute. ECOSE Pipe Insulation with ECOSE Technology

26 ECOSE Pipe Insulation Description Knauf Insulation ECOSE Pipe Insulation is a molded, heavy-density, one-piece insulation made from inorganic Glass Mineral Wool bonded with ECOSE Technology. It is produced in 1.2 meter lengths with or without a factory-applied jacket. ASJ+ is the newest generation all-service jacket composed of aluminum foil, reinforced with a glass scrim bonded to a kraft paper interleaving with an outer film layer leaving no paper exposed. A matching ASJ+ butt strip is furnished in the carton for each section. The jacket is white, and the longitudinal lap of the jacket has a self-sealing adhesive. The SSL+ Advanced Closure System creates a strong and lasting bond. ECOSE Technology ECOSE Technology is a revolutionary binder based on rapidly renewable bio-based materials rather than non-renewable petroleum-based chemicals such as phenol, formaldehyde or acrylics. ECOSE Technology reduces Knauf Insulation s binder embodied energy and contains no phenol, formaldehyde, acrylics, artificial colors or UREA found in traditional Glass Mineral Wool insulation. ECOSE Pipe Insulation is used to insulate iron and copper piping in industrial applications and in commercial and institutional buildings. ECOSE Pipe Insulation is suitable for hot, cold, concealed and exposed piping systems operating at temperatures from 0 F-1000 F (-18 C to 538 C). Additional weather protection is needed outdoors. Features and Benefits Energy Conservation Offers excellent resistance to heat loss or gain, which saves energy and lowers operating costs A low thermal conductivity of.23 at 75 F (24 C) Low-Cost Installation ASJ+ faced pipe insulation has a self-sealing lap, which eliminates the need for staples, additional material and tools. Fast, easy installation reduces labor costs Condensation Control Installed properly, the foil vapor retarder and pressure-sensitive lap assure a positive vapor seal. UL Classified ECOSE Pipe Insulation, plain or jacketed, meets the fire and smoke safety requirements of most federal, state and local building codes. Easy Size Identification Pipe size, wall thickness and Proto 25/50 Rated PVC fitting cover size are printed in a repeat pattern along the longitudinal lap Easy identification at job site Simplifies restocking ASJ+ SSL+ Professional finished appearance dimple and wrinkle resistant Cleanable with a wet cloth and soapy water Moisture resistant to intermittent, short duration liquid water exposure, such as precipitation during construction phase ASJ+ has substantially less degradation and discoloration when exposed to UV. ASJ+ meets ASTM C1136 Type I, II, III, IV, and meets VIII based on the 75% better puncture resistance of ASJ+ (Mullen Burst). The SSL+ Advanced Closure System creates a strong and lasting bond. Indoor Air Quality The GREENGUARD Certification Program (formerly known as GREENGUARD Indoor Air Quality Certification) gives assurance that products designed for use in indoor spaces meet strict chemical emissions limits, which contribute to the creation of healthier interiors. Achieving GREENGUARD Certification gives credence to manufacturers sustainability claims, backing them with empirical scientific data from an unbiased, third-party organization. Sustainability Carbon negative: meaning Knauf Insulation products used for thermal insulating purposes recover the energy that it took to make them in just hours or a few days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. ECOSE Glass Mineral Wool insulation contains three primary ingredients: Sand, one of the world s most abundant and renewable resources A minimum 60% recycled post-consumer glass content and UL Environment verification every 6 months ECOSE Technology which reduces binder embodied energy by up to 70% It is anticipated to reduce its Global Warming Potential (GWP) by approximately 4%, a significant reduction in our carbon footprint Specification Compliance ASTM C 547; Type I, Type IV ASTM C 585 ASTM C 795 ASTM C 1136 (jackets); Type I, II, III, IV,VIII GREENGUARD Certified GREENGUARD GOLD SM and verified to be formaldehyde free NFPA 90A and 90B NRC Reg. Guide 1.36 (certification needs to be specified at time of order) This product complies with Oregon Revised Statue and contains less than 0.10% decabromdiphenyl ether (DecaBDE) by mass. Technical Data - Earthwool 1000 Pipe Insulation UL/ULC Classified Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, CAN/ULC S102-M88, NFPA 255 and UL 723 Temperature Limitation (ASTM C 411 & ASTM C 447) Up to 840 F (450 C) at a maximum recommended thickness of 6 inches Corrosiveness (ASTM C 665) Does not accelerate corrosion on steel, copper or aluminum Corrosion (ASTM C 1617) The corrosion rate in mils/yr will not exceed that of 1 ppm chloride solution. Microbial Growth (ASTM C 1338) Does not promote microbial growth Water Vapor Sorption (ASTM C 1104) Less than 0.2% by volume Linear Shrinkage (ASTM C 356) Negligible Thermal Efficiency (ASTM C 335) Mean Temperature k k (SI) 75 F (24 C) F (38 C) F (93 C) F (149 C) F (204 C) F (260 C) F (316 C) Minimum Pipe Insulation Thickness (in.) a (to meet ASHRAE 90.1 Requirements) Fluid Design Operating Temperature Range, F Insulation Conductivity Conductivity Range BTU-in./ (hr ft 2 F) Technical Data - ASJ+ UL/ULC Classified Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, CAN/ULC S102-M88, NFPA 255 and UL 723 Specification Compliance ASTM C 1136 (jackets); Type I, II, III, IV, VIII Mean Temperature Rating, F <1 Nominal Pipe or Tube Size (in.) 1 to <1½ 1½ to <4 4 to <8 8 Heating and Hot Water Systems (Steam, Steam Condensate, Hot Water Heating and Domestic Water Systems) b,c Above ½ ½ 4½ 4½ ½ 2½ 2½ ½ 1½ ½ 1½ 1½ Cooling Systems (Chilled Water, Brine, Refrigerant) d ½ ½ Below ½ ½ a. For insulation outside the stated conductivity range, the minimum thickness (T) shall be determined as follows: T=r{(1+t/r) K/k -1}. Where T=minimum insulation thickness (in.), r = actual outside radius of pipe (in.), t=insulation thickness listed in this table for applicable fluid temperature and pipe size, K=conductivity of alternate material at mean rating temperature indicated for the applicable fluid temperature {Btu in. (h ft 2 F)}; and k=the upper value of the conductivity range listed in this table for the applicable fluid temperature. b. These thicknesses are based on energy efficiency considerations only. c. For piping smaller than 1½" and located in partitions within conditioned spaces, reduction of these thicknesses by 1" shall be permitted (before thickness adjustment required in footnote a) but not to thicknesses below 1". d. These thicknesses are based on energy efficiency considerations only. Issues such as water vapor permeability or surface condensation sometimes require vapor retarders or additional insulation. e. The table is based on steel pipe. Non-metallic pipes schedule 80 thickness or less shall use the table values. For other non-metallic pipes having thermal resistance greater than that of steel pipe, reduced insulation thicknesses are permitted if documentation is provided showing that the pipe with the proposed insulation has no more heat transfer per foot than a steel pipe of the same size with the insulation thickness shown on the table. Water Vapor Transmission (ASTM E 96, Procedure A) Jacket has a water vapor permeance of.02 perms or less. Water Vapor Sorption (ASTM C 1104) Less than 0.2% by volume Product Forms amd Sizes Produced in 1.2 meter sections: For iron pipe from ½ to 18 nominal pipe size (20 mm to 457 mm) For copper tube from 7 8 to 6 ⅛ (18 mm to 156 mm) Wall thicknesses from 3 4 to 6 (20 mm to 152 mm) in single layer (for most sizes) All insulation inner and outer diameters comply with ASTM C 585 Packaging Four convenient carton sizes for easy ordering, inventory tracking and storage Reinforced carton handles for strength and easy lifting Bar-coded cartons for accurate shipments and tracking Full product range stocked at distributors for fast availability Precautions Hot Pipe May be installed while the system is in operation, at all temperatures up to 840 F (450 C) Knauf Insulation recommends, for insulation thicknesses greater than 6 (152 mm) the temperature must be increased from 500 F (260 C) to maximum temperature at a rate not exceeding 100 F (56 C) per hour. During initial heat-up to operating temperatures above 350 F (177 C), a slight odor and some smoke may be given off as a portion of the bonding material used in the insulation begins to undergo a controlled decomposition. If natural convection is not adequate in confined areas, forced ventilation should be provided in order to protect against any harmful fumes and vapors that might be generated. Care must also be taken when using sealants, solvents or flammable adhesive during installation. A maximum of 6 (152 mm) wall thickness is recommended. Cold Pipe Use a continuous vapor retarder on piping operating below ambient temperatures. Seal all joints, surfaces, seams and fittings to prevent condensation. On below freezing applications, and in high-abuse areas, the ASJ+ jacket shall be protected with a PVC vapor retarding outer jacket. In addition, exposed ends of insulation shall be sealed with vapor barrier mastic installed per the mastic manufacturer s instructions. Vapor seals at butt joints shall be applied at every fourth pipe section joint and at each fitting to isolate any water incursion. On chilled water systems operating in high humidity conditions, it is recommended that the same guidelines be followed as listed above for below freezing applications. Exterior hanger supports are recommended. Outside Do not expose pipe insulation to weather. It must be covered with appropriate jacketing, mastic or vapor retardant adhesives. All exposed surfaces must be protected. Proto Indoor/Outdoor PVC Jacketing is recommended. See Knauf Guide Specifications for recommended PVC jacketing application guidelines. Apply jacketing, mastics or vapor retardant adhesives per manufacturer s instructions. For metallic jackets, factory-applied condensate retarders are recommended. ASJ+ SSL+ Keep adhesive and contact surfaces free from dirt and water, and seal immediately once adhesive is exposed. Apply when ambient and insulation temperatures are between 20 F and 130 F (-6.7 C and 54 C). If stored below 20 F or above 130 F, allow insulation cartons to stand within recommended temperature range for 24 hours prior to application. Do not store product below -20 F (-29 C) or above 150 F (66 C). When using Knauf Insulation s SSL+ Advanced Closure System, make sure the longitudinal and circumferential joints are properly sealed by rubbing the closure firmly with a squeegee. Use of staples is not recommended. When using ECOSE Pipe Insulation, the surface temperature of the insulation should be between -20 F and 150 F (-29 C and 66 C) during the life of the insulation. Fittings and Hangers Use Proto 25/50 Rated (ASTM E 84) PVC Fitting Covers, applying PVC fittings per Proto s Data Sheet. Fittings should be insulated to same thickness as the adjoining insulation. Apply fittings per manufacturer s instructions. When required by specification, a hard insert of sufficient length should be used to avoid compression of the insulation. Additional Precautions Glass Mineral Wool may cause temporary skin irritation. Wear long-sleeved, loose-fitting clothing, head covering, gloves and eye protection when handling and applying material. Wash with soap and warm water after handling. Wash work clothes separately and rinse washer. Use a disposable mask/respirator designed for nuisance-type dusts where sensitivity to dust and airborne particles may cause irritation to the nose or throat. Guidelines Storage Protect insulation from water damage or other abuse, welding sparks and open flame. Cartons are not designed for outside storage. Preparation Apply only on clean, dry surfaces. Pipe or vessel should be tested and released before insulation is applied. General Guidelines All sections should be firmly butted. Seal circumferential joint with a minimum 3 (76 mm) wide butt strip. Jackets, coating and adhesives should have a comparable F.H.C. rating. ASJ+ may be painted. As with traditional ASJ, Knauf Insulation does not encourage the painting of ASJ+ because the application of any paint may change the surface burning characteristics and will void the UL Classification and Knauf Insulation Limited Warranty. Where painting is necessary use common water, oil, or solvent-based paints. All paints should be tested for compatibility and adhesion before use. All piping should have continuous insulation. Position longitudinal lap downward to avoid dirt and moisture infiltration. Do not expose pipe insulation to excessive vibration or physical abuse. Faced insulation should not have a facing temperature above 150 F (66 C). SSL+ Installation Instructions: 1. To install SSL+, first remove the kraft release liner to expose adhesive. 2. Carefully align the jacketing. Starting in the center of the insulation section, begin initial SSL+ tack using pressure in the direction of the overlap. Again, starting in the center of the insulation section, with a plastic squeegee begin to apply firm pressure to the bonded lap area swiping from the center of the insulation section toward each end. NOTE: After initial SSL+ adhesive tack, it is critical that the closure is not re-opened and repositioned on the facing. Doing so will delaminate the jacket and adhesive, diminishing the bond strength. Butt Strip Installation Instructions: 1. To install Butt Strips, remove the kraft release liner by separating the butt strip from the kraft using the convenient, easy release kiss cut. 2. Simply wrap the butt strip, centered around the joint, and apply firm pressure with a squeegee. NOTE: After initial Butt Strip adhesive tack, it is critical that the closure is not re-opened and repositioned on the facing. Doing so will weaken the adhesive and diminish bond strength. Recommended Thicknesses (ASHRAE ) The minimum thicknesses are based on ASHRAE standards and do not necessarily represent the Economic Thickness of Insulation or the thickness required for proper condensation control. Rather, they serve as minimum recommendations for commercial applications. For recommended Economic Thickness, install according to Knauf Insulation or NAIMA 3E Plus programs or as specified. Glass Mineral Wool and Mold Glass Mineral Wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Notes The chemical and physical properties of Knauf Insulation ECOSE Pipe Insulation represent typical average values determined in accordance with accepted test methods. The data is subject to normal manufacturing variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. Check with your Knauf Insulation sales representative to assure information is current.

Knauf Data Sheet AH-DS-12e Sonic XP Duct Liner. with ECOSE Technology

Knauf Data Sheet AH-DS-12e Sonic XP Duct Liner. with ECOSE Technology Knauf Data Sheet AH-DS-12e 09-09 Sonic XP Duct Liner with ECOSE Technology Consistent blanket thickness and uniform fiber distribution provides efficient and hassle-free cutting and pinning on all fabrication

More information

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology Knauf Data Sheet AH-DS-5E 07-09 Friendly Feel with ECOSE Technology Duct Wrap For cooling, heating or dual temperature service. Friendly Feel Duct Wrap meets the most stringent IAQ tests GREENGUARD Children

More information

Knauf Data Sheet CI-DLS-DS Sonic XP. Duct Liner. with ECOSE Technology

Knauf Data Sheet CI-DLS-DS Sonic XP. Duct Liner. with ECOSE Technology Knauf Data Sheet CI-DLS-DS 04-14 Sonic XP with ECOSE Technology Duct Liner Sonic XP Duct Liner with ECOSE Technology Description Knauf Insulation Sonic XP Duct Liner is a flexible, mat-faced insulation

More information

Eclipse TM Air Duct Board. Knauf Data Sheet AH-DS

Eclipse TM Air Duct Board. Knauf Data Sheet AH-DS Eclipse TM Air Duct Board Knauf Data Sheet AH-DS-10 01-08 Eclipse Air Duct Board Description Knauf Eclipse Air Duct Board is a rigid fiber glass board faced on one side with a foil-scrim-kraft (FSK) vapor

More information

Eclipse Air Duct Board

Eclipse Air Duct Board Knauf Data Sheet AH-DS-10e 03-12 Eclipse Air Duct Board with ECOSE Technology Eclipse Air Duct Board with ECOSE Technology Description Knauf Insulation Eclipse Air Duct Board with ECOSE Technology is a

More information

Eclipse Air Duct Board

Eclipse Air Duct Board Knauf Data Sheet AH-DS-10e 08-09 Eclipse Air Duct Board with ECOSE Technology Knauf s unique blackening process provides a deeper black surface than other standard boards, minimizing visibility at venting

More information

Air Duct Board-M with Hydroshield Technology. Knauf Data Sheet AH-DS

Air Duct Board-M with Hydroshield Technology. Knauf Data Sheet AH-DS Air Duct Board-M with Hydroshield Technology Knauf Data Sheet AH-DS-6 08-06 Knauf Air Duct Board-M is faced with a tightly bonded black mat for greater airstream surface durability. Available in both EI-475

More information

Friendly Feel Duct Wrap with KwikStretch Markings. Knauf Data Sheet AH-DS

Friendly Feel Duct Wrap with KwikStretch Markings. Knauf Data Sheet AH-DS Friendly Feel Duct Wrap with KwikStretch Markings Knauf Data Sheet AH-DS-5 05-07 For cooling, heating or dual temperature service. Friendly Feel Duct Wrap meets the most stringent IAQ tests GREENGUARD

More information

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology Knauf Data Sheet PE-DS-2e 8-09 Insulation Board with ECOSE Technology Insulation Board with ECOSE Technology Description Knauf Insulation Board with ECOSE Technology is a thermal and acoustical insulation

More information

Data Sheet CI-DWA-DS Atmosphere. Duct Wrap. with ECOSE Technology

Data Sheet CI-DWA-DS Atmosphere. Duct Wrap. with ECOSE Technology Data Sheet CI-DWA-DS 10-15 Atmosphere with ECOSE Technology Duct Wrap Atmosphere Duct Wrap with ECOSE Technology Description Knauf Insulation Atmosphere Duct Wrap with ECOSE technology is a thermal and

More information

Atmosphere Duct Liner

Atmosphere Duct Liner Data Sheet CI-DLA-DS 02-15 Atmosphere Duct Liner with ECOSE Technology Atmosphere Duct Liner with ECOSE Technology Description Knauf Insulation Atmosphere Duct Liner is a flexible, mat-faced insulation

More information

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology Knauf Data Sheet PE-DS-2e 4-10 Insulation Board with ECOSE Technology o Shrinkage (ASTM C 356) Less than 0.3% linear shrinkage. Resists Microbial Growth (ASTM C 1338, G21) Does not promote or support the

More information

Atmosphere Air Duct Board

Atmosphere Air Duct Board Data Sheet CI-ADB-DS 10-15 Atmosphere Air Duct Board with ECOSE Technology Atmosphere Air Duct Board with ECOSE Technology Description Knauf Insulation Atmosphere Air Duct Board with ECOSE Technology is

More information

Atmosphere Air Duct Board

Atmosphere Air Duct Board Atmosphere Air Duct Board with ECOSE Technology Data Sheet CI-ADBA-DS 09-18 Atmosphere Air Duct Board with ECOSE Technology DESCRIPTION Knauf Insulation Atmosphere Air Duct Board with ECOSE Technology

More information

Insulation Board. Knauf Data Sheet PE-DS

Insulation Board. Knauf Data Sheet PE-DS Insulation Board Knauf Data Sheet PE-DS-2 12-06 Insulation Board Description Knauf Insulation Board is a thermal and acoustical insulation product made from inorganic glass fibers preformed into boards

More information

KwikFlex Pipe & Tank Insulation

KwikFlex Pipe & Tank Insulation Knauf Data Sheet PE-DS-15e 12-09 KwikFlex Pipe & Tank Insulation with ECOSE Technology Knauf KwikFlex offers a unique combination of flexibility and compressive strength in a roll form. Tough and durable,

More information

KwikFlex Pipe & Tank Insulation. Knauf Data Sheet PE-DS

KwikFlex Pipe & Tank Insulation. Knauf Data Sheet PE-DS KwikFlex Pipe & Tank Insulation Knauf Data Sheet PE-DS-15 04-07 Knauf KwikFlex offers a unique combination of fl exibility and compressive strength in a blanket form. Tough and durable, yet easy to handle

More information

Earthwool Insulation Board with ECOSE Technology

Earthwool Insulation Board with ECOSE Technology Data Sheet CI-IB-DS 12-15 Earthwool Insulation Board with ECOSE Technology Knauf Insulation Earthwool Insulation Board is a versatile product for thermal and acoustical applications such as heating and

More information

Air Handling Products

Air Handling Products Full Line Catalog AH-FL-11 05-07 Air Handling Products Air Duct Board-M and AGM, Duct Liner E M, Textile Duct Liner, Rigid Plenum Liner and Duct Wrap A Full Line of Air Handling Products Delivering greater

More information

Redi-Klad 1000 Pipe Insulation

Redi-Klad 1000 Pipe Insulation Knauf Data Sheet PE-DS-16e 12-09 Redi-Klad 1000 Pipe Insulation with ECOSE Technology Knauf Redi-Klad 1000 F Pipe Insulation with ECOSE Technology is offered across a wide range of sizes. For iron pipe

More information

Tel: Fax:

Tel: Fax: This Specification Section is provided in CSI format for engineers and architects specifying fiberglass insulation manufactured by Knauf GmbH. in Shelbyville, Indiana. Delete insulation types not required

More information

SECTION HVAC INSULATION

SECTION HVAC INSULATION PART 1 GENERAL 1.1 SUMMARY SECTION 23 07 00 HVAC INSULATION A. Section Includes: 1. Ductwork insulation. 2. Duct liner. 3. Insulation jackets. 4. Equipment insulation 5. Piping system insulation. 6. Insulation

More information

GUIDE SPECIFICATION: DUCT LINER

GUIDE SPECIFICATION: DUCT LINER GUIDE SPECIFICATION: DUCT LINER This specification guide includes thermal & acoustical insulation for ductwork and air handling systems. This section is based on the format recommended by MICA (Midwest

More information

Knauf Data Sheet PE-DS-1e Earthwool TM 1000 Pipe Insulation

Knauf Data Sheet PE-DS-1e Earthwool TM 1000 Pipe Insulation Knauf Data Sheet PE-DS-1e 04-11 Earthwool TM 1000 Pipe Insulation Earthwool TM 1000 Pipe Insulation Description Knauf Insulation Earthwool 1000 Pipe Insulation is a molded, heavy-density, one-piece insulation

More information

Knauf Data Sheet PE-DS-1e Earthwool Pipe Insulation

Knauf Data Sheet PE-DS-1e Earthwool Pipe Insulation Knauf Data Sheet PE-DS-1e 04-11 Earthwool TM 1000 Pipe Insulation Earthwool TM 1000 Pipe Insulation Description Knauf Insulation Earthwool 1000 Pipe Insulation is a molded, heavy-density, one-piece insulation

More information

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated. SECTION 23 07 13 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Earthwool Redi-Klad 1000 Pipe Insulation

Earthwool Redi-Klad 1000 Pipe Insulation Data Sheet CI-RK-DS 12-15 Earthwool Redi-Klad 1000 Pipe Insulation Knauf Insulation Earthwool Redi-Klad 1000 pipe insulation is a multi-purpose, molded, heavy-density, one-piece glass mineral wool insulation

More information

CertaPro Thermal FSK-25 Faced Batts

CertaPro Thermal FSK-25 Faced Batts CertaPro Thermal FSK-25 Faced Batts ASTM C 553, Type I ASTM C 665, Type III, Class A, Category 1 New York City MEA 19-80-M Light-density fiber glass batts with a foil scrim kraft (FSK) fire resistant vapor

More information

Thermal/Acoustical Insulation. Data Sheet BI-RL-DS 05-18

Thermal/Acoustical Insulation. Data Sheet BI-RL-DS 05-18 Thermal/Acoustical Insulation Data Sheet BI-RL-DS 05-18 Think of it as green... only browner. ECOROLL INSULATION with ECOSE Technology All Knauf Insulation products are sustainable. EcoRoll fiberglass

More information

PROJ. NO SECTION HVAC DUCT INSULATION

PROJ. NO SECTION HVAC DUCT INSULATION SECTION 23 07 13 HVAC DUCT INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

AK BLANKET Temperature Limit: 650 F (343 C)

AK BLANKET Temperature Limit: 650 F (343 C) AK BLANKET Temperature Limit: 650 F (343 C) AK Blanket is an amber blanket of glass fibers bonded with a thermosetting resin. AK Blanket products are used as thermal and/or acoustical insulation in the

More information

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION SECTION 230713 DUCT INSULATION PART 1 GENERAL 1.1 SUMMARY A. Related Sections: 1. 233113 Ductwork and Accessories 1.2 REFERENCES A. American Society for Testing and Materials (ASTM): 1. E84-96a Test Method

More information

A. This Section includes duct and plenum insulation; accessories and attachments; and sealing compounds.

A. This Section includes duct and plenum insulation; accessories and attachments; and sealing compounds. SECTION 230713 DUCT INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

AIR DISTRIBUTION SOLUTIONS QUIETR ECOTOUCH SOFTR PROCAT

AIR DISTRIBUTION SOLUTIONS QUIETR ECOTOUCH SOFTR PROCAT AIR DISTRIBUTION SOLUTIONS QUIETR ECOTOUCH SOFTR PROCAT Owens Corning Air Distribution Solutions 3 EcoTouch Insulation for Flexible Duct 4 QuietR Duct Board 5 ProCat Blown-in Insulation System 6 QuietR

More information

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 08-17

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 08-17 Thermal/Acoustical Insulation Data Sheet BI-BT-DS 08-17 Think of it as green... only browner. ECOBATT INSULATION with ECOSE Technology All Knauf Insulation products are sustainable. EcoBatt glass mineral

More information

YOUR FIBERGLASS SOLUTIONS PROVIDER PRODUCT CATALOG

YOUR FIBERGLASS SOLUTIONS PROVIDER PRODUCT CATALOG www.quietflex.com FIBERGLASS YOUR SOLUTIONS PROVIDER PRODUCT CATALOG LNG LNG Resilient Blanket LNG Suspended Deck Blanket Quietflex Brand LNG Resilient Blanket is designed to offer excellent resiliency

More information

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 2-17

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 2-17 Thermal/Acoustical Insulation Data Sheet BI-BT-DS 2-17 Think of it as green...only browner. Knauf Insulation EcoBatt Insulation with ECOSE Technology All Knauf Insulation products are sustainable. EcoBatt

More information

FIRE STATION 55 June 14, 2010

FIRE STATION 55 June 14, 2010 SECTION 15250 MECHANICAL INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work Includes 1. Insulation of Domestic Water Piping. 2. Pipe Insulation of refrigerant piping. 3. Insulation of ductwork. 4. Aluminum

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Earthwool 1000 Pipe Insulation

Earthwool 1000 Pipe Insulation Data Sheet CI-PE-DS 12-15 Earthwool 1000 Pipe Insulation with ECOSE Technology Knauf Insulation Earthwool 1000 pipe insulation is a molded, heavydensity, one-piece insulation made from inorganic glass

More information

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Thermal/Acoustical Insulation. Knauf Data Sheet BI-BT-DS 08-13

Thermal/Acoustical Insulation. Knauf Data Sheet BI-BT-DS 08-13 Thermal/Acoustical Insulation Knauf Data Sheet BI-BT-DS 08-13 Think of it as green...only browner. Knauf EcoBatt Insulation with ECOSE Technology All Knauf products are sustainable. EcoBatt Glasswool Insulation

More information

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket. SECTION 230719 - HVAC PIPING INSULATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Piping insulation. B. Jackets and accessories. 1.2 RELATED REQUIREMENTS A. Section 07813 - Fire Procection, HVAC & Plumbing

More information

Updated 6/4/2012. Table Of Contents SECTION PLUMBING INSULATION

Updated 6/4/2012. Table Of Contents SECTION PLUMBING INSULATION PART 1 GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 SUBMITTALS FOR INFORMATION 1.4 QUALITY ASSURANCE PART 2 PRODUCTS 2.1 INSULATION MATERIALS 2.2 FACTORY APPLIED JACKETS 2.3 FIELD APPLIED JACKETS PART

More information

EcoTouch Insulation with PureFiber Technology

EcoTouch Insulation with PureFiber Technology PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Knauf Data Sheet BI-DS Thermal/Acoustical Insulation

Knauf Data Sheet BI-DS Thermal/Acoustical Insulation Knauf Data Sheet BI-DS-7 9-09 Thermal/Acoustical Insulation Knauf EcoBatt Think of it as green...only browner. Insulation with ECOSE Technology... All Knauf products are sustainable. EcoBatt Glasswool

More information

PRODUCT SELECTION GUIDE. HVAC Insulation

PRODUCT SELECTION GUIDE. HVAC Insulation PRODUCT SELECTION GUIDE HVAC Insulation TABLE OF CONTENTS DUCT LINER INSULATION Linacoustic RC 3 Linacoustic RC-HP 3 Linacoustic R-300 3 Spiracoustic Plus 4 Spiral SG 4 LinaTex 4 DUCT BOARD INSULATION

More information

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 08-17

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 08-17 Thermal/Acoustical Insulation Data Sheet BI-BT-DS 08-17 Think of it as green... only browner. ECOBATT INSULATION with ECOSE Technology All Knauf Insulation products are sustainable. EcoBatt glass mineral

More information

Earthwool 1000 Pipe Insulation

Earthwool 1000 Pipe Insulation Data Sheet CI-PE-DS 10-17 Earthwool 1000 Pipe Insulation with ECOSE Technology Knauf Insulation Earthwool 1000 pipe insulation is a molded, one-piece insulation made from inorganic glass mineral wool bonded

More information

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 11-15

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 11-15 Thermal/Acoustical Insulation Data Sheet BI-BT-DS 11-15 Think of it as green...only browner. Knauf Insulation EcoBatt Insulation with ECOSE Technology All Knauf Insulation products are sustainable. EcoBatt

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 23 07 00_ HVAC INSULATION PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Piping system insulation. 2. Equipment insulation. 3.

More information

Division 15 INSULATION Section 15100

Division 15 INSULATION Section 15100 Page 1 of 5 SECTION PAGE PART 1 GENERAL 2 1.1 General 2 1.2 References 2 1.3 Work Included 2 1.4 Related Work 2 1.5 Quality Assurance 3 PART 2 PRODUCTS 3 2.1 Description 3 PART 3 EXECUTION 3 3.1 Workmanship

More information

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

1. Division 23 Section Hangers and Supports for HVAC Piping and Equipment for pipe insulation shields and protection saddles. SECTION 23 07 19 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

1 of 17. PO Box Bellevue Rd, Newark, DE V F

1 of 17. PO Box Bellevue Rd, Newark, DE V F 1 of 17 Raw Material Manufactured from 4 8-foot sheets Fiber-reinforced 1-mil aluminumfaced polyisocyanurate panels 0.032 embossed aluminum Other patterns and stainless steel are available Necessary supplies

More information

SECTION PLUMBING INSULATION

SECTION PLUMBING INSULATION SECTION 22 07 00 PLUMBING INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Section includes equipment insulation, covering, and thermal insulation for piping systems including vapor retarders, jackets and accessories.

More information

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Installation Guide QuietR Spiral Duct Liner

Installation Guide QuietR Spiral Duct Liner Table of Contents General Information 1-1 Recommendations and Limitations 2-1 Project Estimating 3-1 Grooving Duct Liner 4-1 Duct Liner Section 5-1 Adhesives Coatings and Pins 6-1 Straight Duct 7-1 Couplings

More information

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION PRE-ENGINEERED BUILDING INSULATION PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered

More information

SECTION MECHANICAL INSULATION. A. Types of insulation specified in this section include the following:

SECTION MECHANICAL INSULATION. A. Types of insulation specified in this section include the following: SECTION 15250 PART I - GENERAL 1.01 WORK INCLUDED A. Types of insulation specified in this section include the following: 1. Piping System Insulation: a. Domestic Cold Water b. Domestic Hot water c. Heating

More information

Techna-Duc. Advantages. Features and Benefits. LEED Eligible Product

Techna-Duc. Advantages. Features and Benefits. LEED Eligible Product Techna-Duc Advantages Techna-Duc is shop fabricated and installed with minimal field alterations. Panels are constructed with polyisocyanurate insulation products that do not promote the growth of mold

More information

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC INSULATION

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC INSULATION DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) PART 1 GENERAL 1.01 DESCRIPTION A. Insulate the following: 1. Piping: a. Heating water b. Chilled water c. Condenser water (outdoors with heat

More information

Construction Standards PAGE

Construction Standards PAGE Construction Standards PAGE 072100-1 SECTION 072100 PART 1 - GENERAL 1.1 M.S.U. ISSUES A. It the intent of MSU that insulation of its projects will comply with LEED NC 3 Credit Requirements EA Prerequisite

More information

SECTION MECHANICAL INSULATION

SECTION MECHANICAL INSULATION SECTION 15250 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work

More information

Introducing Knauf EcoBatt Insulation with ECOSE Technology

Introducing Knauf EcoBatt Insulation with ECOSE Technology www.knaufinsulation.us Introducing Knauf EcoBatt Insulation with ECOSE Technology Be sure your specs are up-to-date and include the new technology that improves the sustainability of traditional fiber

More information

Section Roof/Ceiling Thermal Insulation

Section Roof/Ceiling Thermal Insulation Section 07200 Roof/Ceiling Thermal Insulation Part 1 General 1.01 Summary A. Provide glass fiber thermal insulation for (roof) (ceiling) assembly as indicated in building plans. 1.02 Materials Provided

More information

SECTION (15081) - HVAC INSULATION

SECTION (15081) - HVAC INSULATION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: SECTION 23 07 00 (15081) - HVAC INSULATION 1. Insulation Materials 2. Jackets 3. Accessories and Attachments 4. Vapor Retarders B. Related Sections: 1.02

More information

Addendum to Specifications

Addendum to Specifications Addendum to Specifications SOW #: Construction Specification #: Date: Additions to Specifications: Deletions to Specifications: Engineer Date Design Engineering Manager Date Page 2 of 7 PART 1 - GENERAL

More information

SECTION DUCT INSULATION

SECTION DUCT INSULATION SECTION 23 07 13 - DUCT INSULATION PART I - GENERAL 1.1 SECTION INCLUDES A. Ductwork Insulation B. Fan and Equipment Insulation C. Insulation Jackets D. Insulation Lagging 1.2 RELATED SECTIONS A. Section

More information

ACOUSTICAL WALL TREATMENT SECTION 09840

ACOUSTICAL WALL TREATMENT SECTION 09840 ACOUSTICAL WALL TREATMENT PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Site-fabricated, stretched fabric acoustical wall system built with rigid polymer stretching system to secure fabric over the wall

More information

B. Refer to Section : Air Distribution for lined ductwork requirements.

B. Refer to Section : Air Distribution for lined ductwork requirements. SECTION 230700 MECHANICAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

Roxul RHT. Board Roxul RHT. Flex Roxul RHT. Wrap. High Temperature Insulation for Industrial/Mechanical Applications

Roxul RHT. Board Roxul RHT. Flex Roxul RHT. Wrap. High Temperature Insulation for Industrial/Mechanical Applications HigH TemperaTure industrial/mechanical insulation Roxul RHT Board Roxul RHT Flex Roxul RHT Wrap High Temperature Insulation for Industrial/Mechanical Applications roxul rht Protecting High Temperature

More information

COMPARISON GUIDE TO NON-FIBROUS LINER PERFORMANCE

COMPARISON GUIDE TO NON-FIBROUS LINER PERFORMANCE COMPARISON GUIDE TO NON-FIBROUS LINER PERFORMANCE Performance Counts Selection of a duct lining can be a challenging step in the design process of a building s HVAC system today. Fibrous liners like Johns

More information

ROCKWOOL Board Insulation Section Master Guide Specification Page 1 Jan 2017

ROCKWOOL Board Insulation Section Master Guide Specification Page 1 Jan 2017 Master Guide Specification Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROCKWOOL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual. 1 GENERAL

More information

Duct Wrap Flexible Wraps

Duct Wrap Flexible Wraps Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone

More information

GUIDE SPECIFICATION: MECHANICAL SYSTEMS

GUIDE SPECIFICATION: MECHANICAL SYSTEMS GUIDE SPECIFICATION: MECHANICAL SYSTEMS This specification guide includes thermal & acoustical insulation for piping, equipment, vessels, and air handling systems. This section is based on the format recommended

More information

OptiLiner Banded Liner System, Thermal, Metal Building

OptiLiner Banded Liner System, Thermal, Metal Building PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

State of Alaska Section State Office Building HVAC Fan Replacement MECHANICAL INSULATION

State of Alaska Section State Office Building HVAC Fan Replacement MECHANICAL INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Specific requirements, products and methods of execution which relate to the insulation of ductwork, piping, valves and fittings. B. Related Sections:

More information

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness.

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness. SECTION 15250 PIPING AND EQUIPMENT INSULATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division 1 Specification

More information

K-FLEX DUCT LINER GRAY

K-FLEX DUCT LINER GRAY K-FLEX DUCT LINER GRAY Flexible, Closed Cell Elastomeric Foam Insulation Responsive to Market Industry & Product Expertise 3rd Party Certified Products 25/50-rated up to 2 thick Systems Approach Factory-applied

More information

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700 SECTION 22 0700 - PLUMBING INSULATION PART 1 - GENERAL 1.1 DESCRIPTION OF WORK: A. All work covered in this section consists of furnishing all labor, equipment, materials and accessories, and performing

More information

HVAC Piping Insulation FIBERGLAS Insulation. General Specification Guide SECTION

HVAC Piping Insulation FIBERGLAS Insulation. General Specification Guide SECTION HVAC Piping Insulation FIBERGLAS Insulation General Specification Guide PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals,

More information

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO SECTION 07210 BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Tube Insulation. Fiber Free

Tube Insulation. Fiber Free Fiber Free Tube Insulation Fiber-free, flexible, elastomeric pipe insulation for reliable protection against condensation, mold, energy loss and ultraviolet radiation in residential and commercial applications

More information

APPLICATIONS Rectangular and Round return and supply ductwork in HVAC systems. Does not promote nesting of insects or rodents

APPLICATIONS Rectangular and Round return and supply ductwork in HVAC systems. Does not promote nesting of insects or rodents R-6.0 SUBMITTAL SHEET Hard Plastic Spacers D U C T I N S U L A T I O N R - 6. 0 Features AT A GLANCE: Reflectix Duct Insulation may be installed by wrapping rectangular or round ductwork in HVAC applications

More information

Building Insulation Submittal Form

Building Insulation Submittal Form Smart Ideas. Better Insulation. Building Insulation Submittal Form Johns Manville has revolutionized the building insulation industry by developing an entire line of formaldehyde-free fiber glass building

More information

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1. SECTION 09 7710 FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Decorative ½ / ¾ (13mm/19mm) thick prefinished panel with preengineered attachment clip along with hardware

More information

SECTION STRUCTURAL INSULATED PANELS

SECTION STRUCTURAL INSULATED PANELS SECTION 06120 STRUCTURAL INSULATED PANELS Copyright 2011-2012 Korwall Industries, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural Insulated Roof Panels. B. Structural Insulated

More information

THERMAL INSULATION

THERMAL INSULATION 717 17th Street 80202 PO Box 5108 Denver, CO 80217-5108 Phone: (800) 654-3103 Fax: (303) 978-2318 E-mail: pics@jm.com specjm.com This MANU-SPEC utilizes the Construction Specifications Institute (CSI)

More information

ROCKWOOL Board Insulation Section Master Guide Specification Page 1 Jan 2017

ROCKWOOL Board Insulation Section Master Guide Specification Page 1 Jan 2017 Master Guide Specification Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROCKWOOL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual. 1 GENERAL

More information

Foil Back Gypsum Board

Foil Back Gypsum Board BRAND 09 29 00/NGC Foil Back Gypsum Board brand Foil Back Gypsum Board consists of a fire-resistant gypsum core with a heavy, natural finish and 100-percent recycled paper on the face and a strong liner

More information

Thermasheath-XP. Insulation for Exposed Use

Thermasheath-XP. Insulation for Exposed Use Insulation for Exposed Use PRODUCT DESCRIPTION Rmax Thermasheath-XP is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (Polyiso) foam bonded to durable, embossed

More information

Commercial & Industrial Insulation - Canada Price Book / Service Guidelines

Commercial & Industrial Insulation - Canada Price Book / Service Guidelines Commercial & Industrial Insulation - Canada Price Book / Service Guidelines Effective December 23, 2012 Commercial & Industrial Insulation Price Book / Service Guidelines - Canada Table of Contents Knauf

More information

A. Source Limitations: Obtain each type of building insulation through one source.

A. Source Limitations: Obtain each type of building insulation through one source. SECTION 07210 - BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) Manual of Steel Construction. SECTION 07 42 63 FABRICATED WALL PANEL ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Provide ACCEL-E steel thermal-efficient-panel wall system. 1.2 RELATED SECTIONS A. Section 05 40 00 - Cold Formed

More information

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS Dyplast Products Copyright 2014 1 Rev 0414 DYPLAST PRODUCTS INSTALLATION GUIDELINES ISO-C1 POLYISOCYANURATE

More information

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS Dyplast Products Copyright 2018 1 Rev 0618 DYPLAST PRODUCTS INSTALLATION GUIDELINES ISO-C1 POLYISOCYANURATE

More information

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation Recommended Design Considerations and Guide Specifications For Commercial Building Insulation Date of Issue: October 1, 2004 Recommended Design Considerations and Guide Specifications For Commercial Building

More information

SECTION THERMAL INSULATION

SECTION THERMAL INSULATION PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 21 13 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

ALUGLASS DUCT SYSTEM (KADS)

ALUGLASS DUCT SYSTEM (KADS) ALUGLASS DUCT SYSTEM (KADS) A NEW GENERATION PRODUCT www.kimmcoinsulation.com www.alghanim.com ALUGLASS DUCT SYSTEM (KADS) APPLICATION KIMMCO Aluglass Duct System used for air distribution in HVAC system

More information