PROflex* 60 Hz Reverse Osmosis Machines from 50 to 360 gpm
|
|
- Victor Sparks
- 6 years ago
- Views:
Transcription
1 Fact Sheet PROflex* 60 Hz Reverse Osmosis Machines from 50 to 60 gpm Flexible Design PROflex has 0 base configurations using 8 to 7 elements that allows user to choose various pumps and membrane element types to work for their specific situation and capex budget. -bank and -bank designs available Footprint is same for all models New design allows for wired devices, motor starters, disconnects, monitors, to be configured and easily customized on the Instrument panel and assembly Pump is in front of skid for easy access and maintenance. Piping is clean and simple allowing for easy modifications, as needed. Standard Features All PROflex machines come standard with the following features: UL/cUL Electrical Panel Primary and final pressure transmitters RO permeate flush on shutdown UL / cul Electrical Panel ph Meter on RO Feed Allen Bradley CompactLogix PLC Control Package Signet Control/Monitoring Package Instrumentation Flow Meters...Permeate & Concentrate Conductivity... Permeate & Feed Pressure... Pre & Post Cartridge Filter RO Feed, Pump Outlet, Inter-stage Concentrate & Permeate Pressure Transmitter... Pre & Post Elements Pressure Switch... Feed, Permeate, Concentrate ph... Feed Find a contact near you by visiting and clicking on Contact Us. * Trademark of General Electric Company; may be registered in one or more countries. 07, General Electric Company. All rights reserved. FSroPROflexNA_EN.docx May-7
2 Configurable Options Available Go to click on Resources then on RO Configurator for more details. Multiple Pump Options use the Configurator Tool to help select the pumps right for your application. Membrane Options: High Rejection Elements Low Energy Elements Nano Elements Motor Starters/Variable Frequency Drive: Mounted or shipped loose. Stainless Steel Upgrade options: Housings Low Pressure Piping Cartridge Filter Housing Recycle Banks by bank cleaning on two stage (S) systems 575V Motors NEMA 4X Control Panel Instrument Packages - Rosemount - E&H - No Instruments PRO NA Accessories PRO Multi-Media filters PRO Activated Carbon and Softeners PRO Clean-in-Place units PRO Chemical Feed Systems Transfer Pumps and Storage Tanks Operating Parameters Use Winflows as guide for specific rates and ranges with your machine. Design Recovery... 80% Design Temperature... 60ºF (6ºC) Operating Temperature Range5-85ºF (-9ºC) Nominal rejection % System Inlet Pressure PSI Recovery Rate can vary +/- 5% Materials of Construction High-pressure piping... 6 Stainless Steel, Sch. 0 Low-pressure piping... PVC, Sch. 80 Frame... Painted blue carbon steel Enclosure... Nema 4 Clamps/fittings... Zinc-plated Membrane Elements and Housings Membrane Model... AG8040F-400 Style... Spiral-wound elements Membrane type... TFC(Polyamide) Average membrane flux gfd Membrane rejection to 99.5% Membrane Element Manufacturer... GE Housing material... FRP or 6 Stainless Steel Housing Pressure Rating psi Housing Manufacturer... Codeline or Equal Flux can be reduced by using 440-sqft membranes. Cartridge Filtration Housing model... ROPV or Equal Housing material...frp Cartridge filter. -micron nominal, HF.Zs 0-40-FSB Page FSroPROflexNA_EN.docx
3 PROflex True flexibility to design a system you want PROflex offers the flexibility to choose a system that allows you to choose an aggressive or conservative design to meet the capital requirements of your specific situation. PROflex allows complete choice on arrays, number of elements, and pump sizes within each array. Figure shows the PROflex product line and the flow ranges. The flow ranges are the hydraulic limits with each model. Users should choose their RO system by determining:. Desired permeate flow range. Temperature of the water. Square footage of the membranes needed (or flux limits), per element 4. Desired Recovery. 5. Recycle, if any. Figure : PROflex flow ranges NOTE: The Pre-Configured Starting points in Figure give you a place to start, and are designs that we may have in stock. They show flow location using the base assumptions of: ) 60 F Feedwater temperature ) 400 sq. ft, elements AG Elements ) 80% RO recovery 4) * Pump shown in the charts below Use the Configurator Tool and Winflows to determine other designs that move you to different points in the bars above, for example: different elements, pumps, and recovery. These different points will allow you to see changes to the capital investment once makes and weighs with design considerations. Further, move left or right in above chart to further affect flux and capex spend. FSroPROflexNA_EN.docx Page
4 PROflex Stage (S) NA Models MODEL PROflex-8-S PROflex-0-S PROflex-6-S PROflex-54-S PROflex-7-S Permeate Rate : Concentrate Rate: Concentrate Recycle: Feed Rate: Model: Manufacturer: Quantity: Motor Power and type: Installed Power: Design Flow Rate: Design boost pressure: Membranes Quantity: Memb. Housing Style: Banking Arrangement: Housing Model: Housing Quantity: Cartridge Filter Model: Cartridge Filter Length: Cartridge Filter Qty: Inlet: Permeate: Concentrate: Inlet Water Pressure: Air Pressure: Drain to be Sized for: Power: Control Circuit Height: Width: Depth: Skid Shipping Weight Estimate Without Membranes: Membranes Shipping Weight Estimate: Operating Weight Estimate: 85 gpm (0 m /hr) gpm (5 m /hr) 06 gpm (4 m /hr) SS5 40 Hp (0 KW) TEFC 0 KW 06 gpm (4 m /hr) 40 psig (6 Bar) 8 HSG,HXHF0-.0V-FRP-A HF.Zs 0-40-FSB 40-inch (0 cm) per housing, /change out.0 flange.5 flange 06 gpm (4 m /hr) 0 VAC, -phase, 50 (7 cm) 57 lb (59 kg) 60 lb (57 kg) 40 gpm ( m /hr) 5 gpm (8 m /hr) 75 gpm (40 m /hr) SS gpm (40 m /hr) 5 psig (6 Bar) 0 HSG,HXHF0-.0V-FRP-A HF.Zs 0-40-FSB 40-inch (0 cm) per housing, /change out.5 flange 75 gpm (40 m /hr) 0 VAC, -phase, 50 (7 cm) 57 lb (59 kg) 60 lb (57 kg) 70 gpm (8 m /hr) 4 gpm (0 m /hr) gpm (49 m /hr) SS4009 gpm (4 m /hr) 40 psig (6 Bar) 6 4 HSG,HXHF0-.0V-FRP-A HF.Zs 0-40-FSB 40-inch (0 cm) per housing, /change out.5 flange gpm (49 m /hr) 0 VAC, -phase, 50 (7 cm) 57 lb (59 kg) 60 lb (57 kg) 55 gpm (59 m /hr) 64 gpm (5 m /hr) 9 gpm (7 m /hr) 75 Hp () TEFC 9 gpm (7 m /hr) 40 psig (6 Bar) 54 6 HSG,HXHF0-.0V-FRP-A HF.Zs 0-40-FSB 40-inch (0 cm) per housing, /change out.0 flange 9 gpm (7 m /hr) 0 VAC, -phase, 50 (7 cm) 57 lb (59 kg) 60 lb (57 kg) 40 gpm (78 m /hr) 85 gpm (0 m /hr) 45 gpm (98 m /hr) 75 Hp () TEFC 45 gpm (98 m /hr) 5 psig (6 Bar) 7 84 HSG,HXHF0-.0V-FRP-A HF.Zs 0-40-FSB 40-inch (0 cm) per housing, /change out.0 flange 45 gpm (98 m /hr) 0 VAC, -phase, 50 (7 cm) 57 lb (59 kg) 60 lb (57 kg) Permeate ranges are stated at the following design conditions: 500 ppm TDS, 80% recovery, 60F, pump listed, and using 400 ft AG elements. Your flow rate will vary greatly as you change temperature, elements and pump sizes and TDS levels. Consult GE or Winflows for flows expected with your feed water conditions. Recycle Rate will vary with flux and feedwater conditions. When to use recycle will depend on the tradeoff user wants to make between permeate quality and membrane element life/frequency of cleaning. The base S models do not come with recycle but there is an option to add recycle in the configurator. Page 4 FSroPROflexNA_EN.docx
5 PROflex Stage (S) NA Models MODEL PROflex-4-S PROflex-6-S PROflex-4-S PROflex-54-S PROflex-7-S Permeate Rate : Concentrate Rate: Concentrate Recycle: Feed Rate: 00 gpm ( m/hr) 5 gpm (6 m/hr) 5 gpm (9 m/hr) 60 gpm (7 m /hr) 40 gpm (9 m /hr) 00 gpm (46 m /hr) 90 gpm (44 m /hr) 48 gpm ( m /hr) 8 gpm (55 m /hr) 5 gpm (5 m /hr) 56 gpm ( m /hr) 8 gpm (65 m /hr) 5 gpm (7 m /hr) 79 gpm (8 m /hr) 94 gpm (9 m /hr) Model: Manufacturer: Quantity: Motor Power and type: Installed Power: Design Flow Rate: Design boost pressure: SS5 40 Hp (0 KW) TEFC 0 KW 5 gpm (9 m/hr) 40 psig (6 Bar) SS gpm (46 m /hr) 50 psig (7 Bar) AS00 8 gpm (55 m /hr) 60 psig (8 Bar) AS00 8 gpm (65 m /hr) 40 psig (6 Bar) 75 Hp () TEFC 94 gpm (9 m /hr) 50 psig (7 Bar) Membranes Quantity: Memb. Housing Style: Banking Arrangement: Housing Model: Housing Quantity: Cartridge Filter Model: Cartridge Filter Length: Cartridge Filter Qty: HSG,HXHF0-.0V-FRP-A HF.Zs 0-40-FSB 40-inch (0 cm) per housing, /change out HSG,HXHF0-.0V-FRP-A HF.Zs 0-40-FSB 40-inch (0 cm) per housing, /change out HSG,HXHF0-.0V-FRP-A HF.Zs 0-40-FSB 40-inch (0 cm) per housing, /change out HSG,HXHF0-.0V-FRP-A HF.Zs 0-40-FSB 40-inch (0 cm) per housing, /change out HSG,HXHF0-.0V-FRP-A HF.Zs 0-40-FSB 40-inch (0 cm) per housing, /change out Inlet: Permeate: Concentrate: Inlet Water Pressure: Air Pressure: Drain to be Sized for: Power: Control Circuit.5 flange 5 gpm (9 m/hr) VAC, - phase, 0 VAC, -phase,.5 flange 00 gpm (46 m /hr) 0 VAC, -phase,.5 flange 8 gpm (55 m /hr) 0 VAC, -phase,.0 flange 8 gpm (65 m /hr) 0 VAC, -phase,.0 flange 94 gpm (9 m /hr) 0 VAC, -phase, Height: Width: Depth: Skid Shipping Weight Estimate Without Membranes: Membranes Shipping Weight Estimate: Operating Weight Estimate: 50 (7 cm) 57 lb (59 kg) 60 lb (57 kg) 50 (7 cm) 57 lb (59 kg) 60 lb (57 kg) 50 (7 cm) 57 lb (59 kg) 60 lb (57 kg) 50 (7 cm) 57 lb (59 kg) 60 lb (57 kg) 50 (7 cm) 57 lb (59 kg) 60 lb (57 kg) Permeate ranges are stated at the following design conditions: 500 ppm TDS, 80% recovery, 60F, pump listed, and using 400 ft AG elements. Your flow rate will vary greatly as you change temperature, elements and pump sizes and TDS levels. Consult GE or Winflows for flows expected with your feed water conditions. Recycle Rate will vary with flux and feedwater conditions. When to use recycle will depend on the tradeoff user wants to make between permeate quality and membrane element life/frequency of cleaning. The base S models do not come with recycle but there is an option to add recycle in the configurator. FSroPROflexNA_EN.docx Page 5
PROflex* 60 Hz reverse osmosis machines from 50 to 360 gpm (12-82 m 3 /hr) Water Technologies & Solutions fact sheet.
Water Technologies & Solutions fact sheet PROflex* 60 Hz reverse osmosis machines from 50 to 60 gpm ( - 8 m /hr) flexible design PROflex has 0 base configurations using 8 to 7 elements that allows user
More informationPROflex* What is PROflex? Water Technologies & Solutions capability profile. give me an example of how PROflex can have a lower price.
Water Technologies & Solutions capability profile PROflex* What is PROflex? PROflex is SUEZ s newest, most flexible RO system. The PROflex is based on years of customer feedback, incorporating improvements
More informationProduct Description / Equipment Specifications FlowMAX Reverse Osmosis Products FM Horizontal Pump Series
Product Description / Equipment Specifications FlowMAX Reverse Osmosis Products FM Horizontal Pump Series General Description: FlowMAX FM Series reverse osmosis units are designed and manufactured for
More informationREVERSE OSMOSIS WATER TREATMENT
REVERSE OSMOSIS WATER TREATMENT LTF 2, LTF 3 and LTF 4 SERIES RO SYSTEMS 14,400 TO 252,000 GALLONS PER DAY AND LARGER Lakeside Water for Affordable Pure Water Technology 1 P age Packaged Reverse Osmosis
More informationCommercial Reverse Osmosis System
Commercial Reverse Osmosis System Aqua Clear Water Treatment Specialists manufacturers and engineers standard and custom commercial reverse osmosis systems water to accomodate many different water conditions.
More informationFLOW REVERSAL DESALINATION TECHNOLOGY
FLOW REVERSAL DESALINATION TECHNOLOGY Novel RO process for Ultra-High Recovery Desalination for drinking and process water Operation Facility Shahak Industrial Park, 3786200 M.P. Menashe, Israel Mobile:
More informationSea Water Reverse Osmosis Container. 1. Description:
Sea Water Reverse Osmosis Container 1. Description: One (1) Containerized Desalination Sea Water Reverse Osmosis process automatic operation with a capacity of 100 m3/day (18.5 gpm). Memco model for MSW-
More informationSpecifications: MoBetta Pro Series Water Store Skid 2600/5200/7800
Specifications: MoBetta Pro Series Water Store Skid 2600/5200/7800 Product Offering Overview Part Number Product Flow Rate Mobetta Pro Series Water Store Skid 2600-1.81 USGPM 2600/5200/7800 5200-3.62 USGPM
More informationSPECIFICATIONS FOR SANBORN OILY WASTEWATER WASTE MINIMIZATION UNIT MODEL UFV750T
SPECIFICATIONS FOR SANBORN OILY WASTEWATER WASTE MINIMIZATION UNIT MODEL UFV750T Oily Wastewater Waste Minimization System Model UFV750T Oily Wastewater Waste Minimization System designed for unattended
More informationElectroChemTM Advanced EDR
barium 56 Ba 137.33 calcium 20 Ca TM 40.078 zinc 30 Zn 65.39 arsenic 33 As 74.922 selenium 34 Se 78.96 chlorine 17 CI 35.453 Next generation electrodialysis reversal (EDR) and IonFlux TM membranes Desalinate
More informationWATER TREATMENT PLANT BASED ON REVERSE OSMOSIS TECHNOLOGY litres Per Hour
WATER TREATMENT PLANT BASED ON REVERSE OSMOSIS TECHNOLOGY Capacity: 25000 litres Per Hour 1 TECHNICAL SPECIFICATIONS Flow Rate : Feed Water : 48000 LPH Treated Water : 25000 LPH 1 RAW WATER PUMP To feed
More informationDemandPure Commercial EDI Systems
Commercial EDI Systems Model Frame Pressure Gauges Valves Switches Description 200 300 400 500 Welded stainless steel tube Filter inlet/outlet, product, concentrate, electrode inlet: SS case, bronze internals,
More informationAXEON Tap Water Reverse Osmosis Systems... SECTION 1. FLEXEON Tap Water Reverse Osmosis Systems... SECTION 2
AXEON Tap Water Reverse Osmosis Systems.............. SECTION 1 AXEON CRO Series Reverse Osmosis System..................................... 1 2 AXEON L1 Series Reverse Osmosis Systems.......................................
More informationCommercial Reverse Osmosis Systems and Accessories
Section 10 Commercial Reverse Osmosis Systems and Accessories R13 Compact Wall Mount RO Commercial Reverse Osmosis Systems And Accessories 249 Commercial Reverse Osmosis Systems And Accessories Specifications
More informationSeawater Desalination Plant General Specification
Seawater Desalination Plant General Specification *Desalination plant design will depend on indivdual customer s requiements. Chlorine Dosing System of different functions such as the stroke length and
More informationOPERATIONS AND MAINTENANCE MANUAL. E8 Series Water Purification Machines
OPERATIONS AND MAINTENANCE MANUAL s 57,000 GPD to 144,000 GPD 216 m 3 /day to 545 m 3 /day NOTICE The enclosed materials are considered proprietary property of GE Water & Process Technologies. No assignments,
More informationAEE Water Experts. AKIKI Engineering Est. Commercial Sand Filter. Filtration
Commercial Sand Akiki Engineering Series Commercial Sand s are constructed based on efficient and economical method for reducing suspended method down to 40 microns in size on various feed water sources.
More informationThe Basics. Reverse Osmosis is a process that is used to remove. Front Side 1. Controller
The Basics Front Side 1. Controller 2. Transformer/relay 3. Inlet 3 /4 BSPM 4. Drain Outlet 3 /4 BSPM 5. GAC Filter 6. Pressure control 7. Low pressure gauge 8. Pump pressure gauge 9. Back pressure gauge
More informationSPECIFICATIONS - DETAILED PROVISIONS Section Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S
SPECIFICATIONS - DETAILED PROVISIONS Section 11241 - Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S PART 1 - GENERAL... 1 1.01 Scope... 1 1.02 Scope of Work... 1 1.03
More informationINDUSTRIAL SEPARATE BED DEIONIZER. FDI Series. High Purity Industrial Packaged System
INDUSTRIAL SEPARATE BED DEIONIZER High Purity Industrial Packaged System (Twin System with carbon Filtration Tanks shown) 1 P age Deionization is the removal or reduction of positive ions called cations
More informationINDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series
INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series (Single, Twin, Triple or Quadruple Demand Systems) 1 P age filtration equipment can be engineered to solve complex commercial and industrial water treatment
More informationMission Statement. Profile and History. R.O. UltraTec s Advantages
2005 PRODUCT CATALOG» Reverse Osmosis Systems» Water Coolers» Filter Cartridges» Filter Housings» Filtration Systems & Water Softeners» Membrane Housings» Membranes» Pumps & Motors» Disinfection Equipment
More informationIndustrial / Municipal
17/04/15 F19-1 Flow & Metering Accessories Industrial / Municipal EX Series IP Series FT Series DL76 Flow Monitoring and Control Magnetic Flow Meters (Magmeters) Paddle Wheel Flow Meters Contacting Meters
More informationWATER TREATMENT SYSTEMS. Reverse Osmosis, Water Softening, and Dechlorination
WATER TREATMENT SYSTEMS Reverse Osmosis, Water Softening, and Dechlorination Delivers softened and/or reverse osmosis water for a wide variety of applications and processes Stand-alone or complementary
More informationMASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version
MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SCP Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description
More informationNever underestimate your fresh water needs
C-2 Never underestimate your fresh water needs Sea Recovery creates the perfect watermaker for large yachts by combining industrial-strength production with space saving designs. Coral Sea systems are
More informationOPERATIONS AND MAINTENANCE MANUAL
OPERATIONS AND MAINTENANCE MANUAL s 16,000 GPD to 43,200 GPD 60.6 m 3 /day to 163.5 m 3 /day NOTICE The enclosed materials are considered proprietary property of GE Water & Process Technologies. No assignments,
More informationMASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version
MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SC Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description
More informationU-Version. Incoming City Water
Ultra-Flo U-Version Ultra-Flo is a hollow-fibre based membrane filtration product. This filtration process covers the ultrafiltration range of between 0.1 to 0.01 micron. It is designed to remove suspended
More informationThe Culligan Hi-Flo 50 Series Industrial Water Filter System
The Culligan Hi-Flo 50 Series Industrial Water Filter System Durable High-Volume Water Filtration for Industrial Applications The Culligan Hi-Flo 50 Filter reduces contaminants* and solids that affect
More informationAkiki Engineering Est.
Akiki Engineering Est. Water & Steam Experts 1.1. Filtration Catalogue October 7, 2010 Contents Commercial Sand Filter................................. 3 Commercial Carbon Filter................................
More informationReverse Osmosis Desalinators
Reverse Osmosis Desalinators H2O Series Framed and Modular Technical Specification Cathelco Seafresh, Marine House,Dunston Rd, Chesterfield, Derbyshire, England, S41 8NY Tel: +44 (0)1246 45790 Fax: +44
More informationYou get more for less at FSHS!
You get more for less at FSHS! www.puromax.com Phone (941)625 4550 Fax (941)625-6635 4210 Whidden Blvd. Port Charlotte, FL 33980 Phone (941)625-4550 Fax (941)625-6635 www.puromax.com Contacts President
More informationTreatment or Process Filtration
Reaction Tanks Advanced Membrane Filtration Memtek EFC-Series Microfiltration System A Major Advantage for Reliable Wastewater Treatment or Process Filtration Systems That Give You Greater Flexibility
More informationSERIES L ,000 GPD RO SYSTEMS
SERIES L 300 19,000 GPD RO SYSTEMS Reverse Osmosis Systems 300 to 19,000 Gallons/Day For feed water TDS 500 to 1000 PPM Designed to produce low dissolved solids water from tap or well water, these RO systems
More information'HR' SERIES INDUSTRIAL HIGH REJECTION SYSTEMS
'HR' SERIES INDUSTRIAL HIGH REJECTION SYSTEMS STANDARD FEATURES PRE-TREATMENT WITH AUTOMATIC MEDIA FILTERS PRE-RO 5 MICRON FILTRATION 365 ft 2 (40") & 575 ft 2 (60") AREA PER RO MEMBRANE ANTISCALANT DOSING
More informationREACTION TANKS ADVANCED MEMBRANE FILTRATION
REACTION TANKS ADVANCED MEMBRANE FILTRATION Memtek EFC-Series Microfiltration System A MAJOR ADVANTAGE FOR RELIABLE WASTEWATER TREATMENT OR PROCESS FILTRATION SYSTEMS THAT GIVE YOU GREATER FLEXIBILITY
More informationCleaning. DATA Monitoring
Cleaning Over time, membrane systems can become fouled with any of a number of foulants such as colloids, organic matter, metallic scales, and biological constituents. (See Pretreatment). These materials
More informationREVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION, AND MAINTENANCE MANUAL
REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION, AND MAINTENANCE MANUAL Table of Contents REVERSE OSMOSIS SYSTEM...1 1. INTRODUCTION...1 2. SYSTEM INFORMATION...1 3. INSTALLATION...2 4. FEED WATER SPECIFICATIONS...3
More informationREVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL. R12-Wall Mount
REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL R12-Wall Mount IMPORTANT Please read the entire manual before proceeding with the installation and startup: Do not use where the water is microbiologically
More informationSAF Filters. The automatic self-cleaning filter - suitable for more applications than ever.
SAF Filters flow rates filtration degrees water for cleaning min. operating pressure up to 400 m³/h (1760 US gpm) 800- micron less than 1% of the total flow bar (30 psi) The automatic self-cleaning filter
More informationOPERATION AND MAINTENANCE MANUAL OSMO PRO Series
OPERATION AND MAINTENANCE MANUAL Revision 3 December 2013 Prepared For: Client Name Plant Location Prepared By: GE Power & Water - Water & Process Technologies 5951 Clearwater Drive Minnetonka, MN, 55343,
More information1500G-3000G USER'S MANUAL. Trouble shooting
Trouble shooting Problem Possible reason Solution System is not functioning 1.Controller box set at 0..The pressure of feed water isn't high enough. ( more than 1.5kg/cm ) 1.Make an adjustment..check water-in
More informationNOTES P: 888-H2O-LOGIC ( ) F:
NOTES P: 888-H2O-LOGIC (426-5644) F: 831-336-9840 info@hydrologicsystems.com www.hydrologicsystems.com BEFORE INSTALLING THE RO SYSTEM WARRANTY Best performance of the system will be achieved when the
More informationCONTENTS. reverse osmosis _02. the R.O. plant _04. Micro series _06. LE/HR series _08. series from 500 to 1250 l/h _10
REVERSE OSMOSIS CONTENTS reverse osmosis _02 the R.O. plant _04 Micro series _06 LE/HR series _08 series from 500 to 1250 l/h _10 series from 1500 to 28000 l/h _12 accessories _14 customised configurations
More informationCommercial. Softeners Filters Reverse Osmosis
Softeners Filters Reverse Osmosis Commercial Expertise has dedicated Professional Engineers with decades of commercial water treatment experience to compliment our knowledgeable field sales team. Together
More informationFOR THOSE WHO WANT TO STAY AHEAD IN ENVIRONMENTAL and quality issues. desalination
FOR THOSE WHO WANT TO STAY AHEAD IN ENVIRONMENTAL and quality issues desalination W h o is W a t M a n? C O M P A N Y O V E R V I E W Water Engineering OEM-Equipment Manufacturing Oy Wat Man Ab Water Management
More informationPURE-PRO REVERSE OSMOSIS SYSTEM
REVERSE OSMOSIS SYSTEM 15 RO36000 Industrial RO System 01 Feed water quality requirement 01 System specifications 02 Part list 07 Installation 08 Operation process & maintenance 10 Trouble shooting 13
More informationPSP Series Water Purification Systems
Operations and Maintenance Manual for PSP Series Water Purification Systems PSP-1000 PSP-1600 PSP-2700 Rev. 2 / 08/26/14 Compact Design, Self-Contained Water Processing Unit for Point-Of-Use or Point-Of-Entry
More informationAdvanced water purifier system operation manual and setup guide
Advanced water purifier system operation manual and setup guide What is Reverse Osmosis? Reverse osmosis, also known as hyper filtration, is the finest filtration known. This process will allow the removal
More informationOverview. Commercial High-Purity Water Systems and Applications. Quality Water Is Our Business
Commercial High-Purity Water Systems and Applications Quality Water Is Our Business Overview High-purity water: definitions High-purity water: methods o Distillation o Deionization o Membrane filtration
More informationEBS Filters. The largest automatic self-cleaning filter for fine filtration. features: up to 7200 m³/h (32000 US gpm) less than 1% of the total flow
EBS Filters flow rates filtration degrees water for cleaning min. operating pressure up to 7200 m³/h (32000 US gpm) 800-10 micron less than 1% of the total flow 2 bar (30 psi) The largest automatic self-cleaning
More informationG L Pumps. SSV Series. Vertical Multistage Pumps. New!! Expanded Range Capable of Flows up to 650 GPM!! Goulds Pumps.
G L Pumps SSV Series Vertical Multistage Pumps New!! Expanded Range Capable of Flows up to 650 GPM!! www.goulds.com Goulds Pumps ITT Industries SSV a tradition of Superior Multi-Stage Pump Design Building
More informationflow rates filtration degrees water for cleaning minimum operating pressure micron less than 1% of the total flow
Pelmar Engineering Ltd. Tel. (888) 754-639, (416) 88-1736 E-mail: sales@pelmareng.com Web site: www.pelmareng.com SAF Filters The automatic self-cleaning filter - suitable for more applications than ever
More informationWater supplied by Marafiq does not meet the process requirements.
WATER TREATMENT In Industries Water is used for: a. Drinking b. Cleaning c. Cooling d. Producing Steam e. Process requirement Why we need to treat water? For human consumption a. Water to be purified (Make
More informationTHE CURRENT USE OF HOLLOW FIBRE ULTRAFILTRATION AS PRE-TREATMENT FOR REVERSE OSMOSIS
THE CURRENT USE OF HOLLOW FIBRE ULTRAFILTRATION AS PRE-TREATMENT FOR REVERSE OSMOSIS Membrane Processes Lower Pressure Membrane Processes Microfiltration (UF) Ultrafiltration (MF) Higher Pressure Membrane
More informationOxiPRO Q2.0 Microbial Control Technology
OxiPRO Q2.0 Microbial Control Technology Specification SPEC-613 OxiPRO Q2.0 Microbial Control Technology improves paper machine efficiency by proactively monitoring and controlling microbial-based deposits.
More informationWATER POWERED HIGH EXPANSION FOAM GENERATORS
WATER POWERED HIGH EXPANSION FOAM GENERATORS Chemguard Standard Model Water Powered (WP) High Expansion Foam Generators are designed to expand foam solution into millions of tiny stable bubbles. Expansion
More informationGerber M Series Site Requirements
Gerber M Series Site Requirements Preparing for the arrival of your new machine. P rior to the arrival of your Gerber M Series Cutting System there are certain things you can prepare to facilitate a quick
More informationSustainable use of Water and Energy. Produced Water Treatment and Recycling Power Generation from Waste Heat
Sustainable use of Water and Energy Produced Water Treatment and Recycling Power Generation from Waste Heat Agenda ExecuVentures Engineering and ECO-TEC Why Produced Water Treatment and Recycling (PWTR)
More informationNew concept of upgrade energy recovery systems within an operating desalination plant.
New concept of upgrade energy recovery systems within an operating desalination plant. Authors: Avner Hermony, Global Environmental Solutions, Ltd., avnerh@viamaris-desal.com Juan Miguel Pinto, Energy
More information.1 All equipment, controls and accessories to be compatible with system design, and matched to the steam boiler(s) by the boiler Manufacturer.
Construction of Sodium Hypochlorite and Chemical Storage Buildings Page 1 of 7 1. GENERAL 1.1 Scope.1 Boiler feed tank and pumps..2 Blowdown tanks..3 Water Softener System 1.2 Quality Assurance.1 All equipment,
More informationNEW LOGIC RESEARCH. Case Study
VSEP Filtration to Remove Suspended Solids in Herbicide Wastewater Advances in Module Designs Enhance Closed Loop Water Treatment Introduction The current trend in the chemical manufacturing industry is
More informationWe are a leader in renewable energy powered water treatment systems.
CATALOGUE 2018 1 We are a leader in renewable energy powered water treatment systems. Solar Water Solutions is a Finnish water treatment technology company. All products are designed and manufactured in
More informationTechnical Specification Industrial Series - IS2 to IS48 Systems. CapDI Benefits. Feed Water Quality. Design and Scope of Supply.
Technical Specification Industrial Series - IS2 to IS48 Systems Voltea s Industrial Series IS systems employ a simple, cost effective modular design providing flexibility to align with both current and
More informationEMERGENCY WATER. Immediate delivery when emergency response for water and/or waste water is required
EMERGENCY WATER Immediate delivery when emergency response for water and/or waste water is required Sigma have wide-spread capabilities in providing robust emergency water solutions. With extensive support
More informationPURE WATER. Installation, Operation and Maintenance Manual. Wall Mounted Commercial Reverse Osmosis Systems. Series PWR2511. Table Of Contents.
Installation, Operation and Maintenance Manual Wall Mounted Commercial Reverse Osmosis Systems Series PWR2511 IOM-WQ-PWR2511 PURE WATER! WARNING Please read carefully before proceeding with installation.
More informationGOULDS PUMPS. Commercial Water. e-sv General Market Specifications. Applications. Specifications
e-sv General Market Specifications Municipal, Agricultural, Light Industry, Water Treatment, Heating and Air Conditioning Applications Handling of water, free of suspended solids, in the municipal, industrial
More informationEnviro Voraxial Technology
1.0 Introduction Enviro Voraxial Technology 821 NW 57 th Place, Fort Lauderdale, FL 33309 Phone 954.958.9968 Fax: 954.958.8057 sales@evtn.com www.evtn.com Case Study Voraxial 4000 Separator On Offshore
More informationWorld-Class Equipment & Process Expertise HFX Marketing Package INCLUDED DOCUMENTS. For more information visit
HFX Marketing Package INCLUDED DOCUMENTS Selection Guide HFX Deionization Systems Brochure HFX35D Water Recycling Datasheet HFX55D Water Recycling Datasheet HFX75D Water Recycling Datasheet HFX115D Water
More informationE4, E4LE, EZ4 Series
E4, E4LE, EZ4 Series Water Purification Machines Operation and Maintenance Manual 2,200 GPD to 13,200 GPD 8.3 m 3 /day to 50 m 3 /day July 4, 2014 Document PN 1161875, Rev G http://www.gewater.com 1 TABLE
More informationseawater desalination REVERSE OSMOSIS (RO) Copyright 2018 MattenPlant Pte Ltd. All rights reserved. MATTEN water technologies made simple
seawater desalination REVERSE OSMOSIS (RO) water technologies made simple 02 RO technology has come a long way. The concepts of osmosis were studied as early as 1748 among scientists. But it was only in
More informationPAHT C pumps ATEX PAHT C pump
MAKING MODERN LIVING POSSIBLE Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Data sheet ATEX PAHT C pump hpp.danfoss.com Table of Contents 1. Introduction...2 2.
More information10.32 Spring 2005 Problem Set 4 Due Friday, April 22, 2005
10.32 Spring 2005 Problem Set 4 Due Friday, April 22, 2005 In class we have been looking at an ultrafiltration system for producing a protein product from the waste whey solution at a cheese plant. The
More information5000 LPH COMPLETE MINERAL WATER PLANT
5000 LPH COMPLETE MINERAL WATER PLANT THE PLANT IS A COMPLETE PLANT FROM RAW WATER PROCESSING, REVERSE OSMOSIS, MICRON FILTRATION AND OZONISATION. THE PLANT HAS 30 BOTTLES PER MUNITE CAPACITY- FILLING
More informationREVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION, AND MAINTENANCE MAUAL
REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION, AND MAINTENANCE MAUAL Table of Contents REVERSE OSMOSIS SYSTEM...1 1. INTRODUCTION...1 2. SYSTEM INFORMATION...1 3. INSTALLATION...2 4. FEED WATER SPECIFICATIONS...3
More informationConstruction of new small scale desalination Units for education sector in the Gaza Strip
The OPEC Fund for International Development (OFID ) UND NATIONS DEVELOPENT PROGRAE Programme of Assistance to the Palestinian People Construction of new small scale desalination Lot#1 South area 1-Alshoka
More informationOrion. Reliable and proven purified water technology with intelligent innovation in the age of sustainability WATER TECHNOLOGIES
Orion Reliable and proven purified water technology with intelligent innovation in the age of sustainability WATER TECHNOLOGIES The next generation of innovative purified water treatment systems for the
More informationPart Numbers. Kinetico Drinking Water Systems. Revised: 07/2016 Drinking Water Systems Parts Pages Section 7 Page 1
Part Numbers Kinetico Drinking Water Systems Revised: 07/2016 Drinking Water Systems Parts Pages Section 7 Page 1 Model 7000/7500 Components 4 7A 1 8 7B 2 5A 3 5B 6A 6B Dwg. No. Description Part No. 1
More informationOrion. Reliable and proven purified water technology with intelligent innovation in the age of sustainability WATER TECHNOLOGIES
Orion Reliable and proven purified water technology with intelligent innovation in the age of sustainability WATER TECHNOLOGIES The next generation of innovative purified water treatment systems for the
More informationUse of Spiral Wound UF in RO Pretreatment
Use of Spiral Wound UF in RO Pretreatment Authors: Harry Dalaly, Asia Pacific Sales Manager, Hydranautics and Yeoh Cheik How, Facilities Senior Engineer, Hewlett-Packard Singapore The Hewlett-Packard Singapore
More informationCOMMERCIAL / INDUSTRIAL COOLING TOWER SIDE STREAM FILTER SYSTEMS
COMMERCIAL / INDUSTRIAL COOLING TOWER SIDE STREAM FILTER SYSTEMS When performance & value matters. WHY DO COOLING TOWERS REQUIRE FILTRATION? Cooling towers are excellent air scrubbers. High volumes of
More information5000TOCi with ISM. Fast, Continuous and Reliable Total Organic Carbon Measurement
5000TOCi with ISM 5000TOCi Sensor Fast, continuous measurement Reliable operation Reagent and chemical free USP , , Ch P, EP 2.2.44, and JP compliant Compact sensor design ISM diagnostics Fast,
More informationWorld-Class Equipment & Process Expertise WDI Marketing Package INCLUDED DOCUMENTS. For more information visit
Selection Guide WDI Deionization Systems Brochure WDI-5 Elite Water Recycling Datasheet WDI-10 Elite Water Recycling Datasheet WDI-15 Elite Water Recycling Datasheet WDI-5 Swift Water Recycling Datasheet
More informationFILMTEC Membranes How FILMTEC Seawater Membranes Can Meet Your Need for High-Pressure Desalination Applications
Tech Fact FILMTEC Membranes How FILMTEC Seawater Membranes Can Meet Your Need for Desalination Higher pressure operation of seawater desalination plants can deliver many benefits, including higher recoveries,
More informationBuderus SB745WS/1550 Stainless Steel Condensing Boiler
Stainless Steel Condensing Boiler Engineering Submittal Sheet Boiler Components R Engineering Specifications The boiler(s) shall have a full three pass fire tube design to allow complete combustion of
More informationCasing Gas Recovery Unit
Standard Features RotorComp NK60 Twin Screw Compressor 25 HP Hydraulic Or Electric Motor 8 x 48 Inlet Scrubber c/w Double Diaphragm Pump 2-4 x 42 Activated Alumina Regenerative Drying Vessels Oil/Gas Discharge
More informationForward Osmosis Applications for the Power Industry
Forward Osmosis Applications for the Power Industry American Filtration Society 2015 Spring Conference Charlotte, North Carolina Bill Harvey Director of Strategy and Business Development Providing world-leading
More informationThe use of an interstage boost on brackish
FWRJ Energy Recovery Case Studies for Brackish Water Membrane Treatment Systems Mark D. Miller, Jason Lee, and Nick Black The use of an interstage boost on brackish reverse osmosis (RO) membrane treatment
More informationAPPLICATIONS THIRD PARTY APPROVALS FEATURES YOUR PRIME CHOICE FOR PROCESS WATER CONTROL SOLUTIONS
YOUR PRIME CHOICE FOR PROCESS WATER CONTROL SOLUTIONS With thousands of panels installed across North America, our team, backed by hundreds of years of experience, designs and builds complete control solutions
More informationFiberglass Cooling Towers
Fiberglass Cooling Towers Available in sizes from 100 to 240 tons. FC Series 700 Fiberglass Cooling Tower Available in sizes from 170 to 240 tons. No other fiberglass cooling tower comes with as many high-quality
More informationPURELAB CHORUS SYSTEMS
REACTION TANKS PURELAB CHORUS SYSTEMS SOLUTIONS FOR TYPE II PURE WATER AND TYPE III GENERAL GRADE WATER CONFIGURE YOUR SOLUTION STEP 1: CHOOSE YOUR SYSTEM INTEGRATED PURIFICATION TECHNOLOGY Typical Applications
More informationIMPROVED BORON REJECTION USING THIN FILM NANOCOMPOSITE (TFN) MEMBRANES IN SEAWATER DESALINATION
IMPROVED BORON REJECTION USING THIN FILM NANOCOMPOSITE (TFN) MEMBRANES IN SEAWATER DESALINATION Simon Bae 15WC: 51678 ABOUT Mission To provide customers with the most innovative and highest quality reverse
More informationProtegra CS RO Series. Meeting All Your Pure Water Demands. Water Technologies
Protegra CS RO Series Meeting All Your Pure Water Demands Water Technologies Solenoid switch gauge Pump RO-Module Flow meter Pre-Filter control Solenoid Service Restrictor Protegra CS RO Series flowsheet
More informationLUBRICATION PUMP Z2 CENTRAL LUBRICATION
LUBRICATION PUMP APPLICATION Lubrication pumps are used as a source of pressure lubricant in the circuits of two-line central lubrication systems. Pumps can be used for lubrication of high number of lubricated
More informationFiltmaster filtration
Filtmaster filtration The effective filtration choice Filtmaster filtration Whether you are storing, transporting or distributing water or wastewater RX Plastics has the solution for you. With manufacturing
More informationSGLP-RO. Installation and Operating Instructions for SCALEGARD TM LP REVERSE OSMOSIS FILTRATION SYSTEM. 3M TM Water Filtration Products
3M TM Water Filtration Products Installation and Operating Instructions for SCALEGARD TM LP REVERSE OSMOSIS FILTRATION SYSTEM SGLP-RO Installer: Please leave this manual with owner/operator. LIMITED WARRANTY
More informationSRO-300 INSTALLATION MANUAL
SRO-300 INSTALLATION MANUAL 12630 US 33 N. Churubusco, IN 46723 Ph. (260)693-1972 Fax (260)693-0602 www.sterlingwatertreatment.com 1 PRE-INSTALLATION Thank you for choosing the Sterling SRO Series commercial
More informationDESIGN AND OPERATION OF A HYBRID RO SYSTEM USING ENERGY SAVING MEMBRANES AND ENERGY RECOVERY TO TREAT SOUTHERN CALIFORNIA GROUND WATER.
DESIGN AND OPERATION OF A HYBRID RO SYSTEM USING ENERGY SAVING MEMBRANES AND ENERGY RECOVERY TO TREAT SOUTHERN CALIFORNIA GROUND WATER Alex Anit, Rich Franks, Craig Bartels, Ph.D. Hydranautics Srinivas
More informationPURE WATER. Installation, Operation and Maintenance Manual. Reverse Osmosis System Series PWRO440. Important. Notes. Table of Contents IOM-WQ-PWRO440
Installation, Operation and Maintenance Manual Reverse Osmosis System Series PWRO440 IOM-WQ-PWRO440 PURE WATER Important Please read the entire manual before proceeding with the installation and startup:
More information