Test report of the room heater OVAL of PANADERO DENIA S.L.

Size: px
Start display at page:

Download "Test report of the room heater OVAL of PANADERO DENIA S.L."

Transcription

1 SGS Environmental Services P.O. Box 5252 NL-6802 EG Arnhem Tel : +31 (0) Fax : +31 (0) BTW : NL B01 R.C. Rotterdam: Test report of the room heater OVAL of PANADERO DENIA S.L. Our reference EZKA/12/069-7 Revision 0 Date report July 13, 2012 Author report J. Dekker SGS registration SGS Nederland B.V.. Malledijk 18 P.O. Box AE Spijkenisse The Netherlands t+31 (0) f+31 (0) R.C. Rotterdam No Member of the SGS Group All orders are executed only in accordance with the latest version of our conditions filed at the Rotterdam District Court or the General Cargo Survey and Inspection Conditions, last version, filed at the Rotterdam District Court and at the Chamber of Commerce in Rotterdam. Upon request the conditions will be sent to you.

2 Revision history Rev. Date Changes 0 July 13, At revision the prior editions of this report are to be discarded. Project managment data General Company name Panadero Denia S.L. Address P.I. Campollano - Avda. 5ª 13-15, ALBACETE, Spain Internet address Reference number customer - Reference number SGS EZKA/12/069-7 Appliance Name Category Material Oval Space heating appliance fired by solid fuel. Steel body. Combustion chamber and baffle plate made of steel. Measurement information Test category Initial type test Method In accordance with NEN EN 13240:2001 and NEN EN A2:2004 Period July 2012 Measurement technician J. Dekker Authentication Consultant Manager Environmental Services J. Dekker J. Boot Quality For our scope of accreditation (RvA L092) of the Environmental department of SGS Nederland BV we refer to the site of the Dutch Council for Accreditation (RvA) ( last three pages Disclaimer Unless otherwise agreed, orders are executed in accordance with the latest version of the SGS Nederland BV General Conditions. Upon simple request the conditions will again be sent to you. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Environmental Services Page 2 of 24 Reportnr.: EZKA/12/069-7

3 Table of contents 1 INTRODUCTION SPECIFICATION OF THE TYPE TEST DESCRIPTION OF THE ROOM HEATER ABSTRACT OF THE TEST RESULTS RESULTS OF ASSESSMENTS USED MATERIALS, DESIGN AND CONSTRUCTION SAFETY REQUIREMENTS APPLIANCE INSTRUCTIONS MARKING MEASUREMENTS TEST FUEL SPECIFICATION PERFORMANCE TEST AT NOMINAL HEAT OUTPUT TEMPERATURE SAFETY ANNEX A ANNEX B ANNEX C ANNEX D ANNEX E SGS Environmental Services Page 3 of 24 Reportnr.: EZKA/12/069-7

4 1 Introduction 1.1 Specification of the type test Test report of a room heater fired by solid fuels in accordance with NEN EN 13240:2001 and NEN EN A2:2004. Laboratory Name, address SGS Nederland BV Leemansweg BX Arnhem The Netherlands Notified under EC number 0608 Manufacturer Principal Appliance Nominal heat output Recommended fuels Test category Panadero Denia S.L. P.I. Campollano - Avda. 5ª ALBACETE Spain Panadero Denia S.L. Oval 11 kw Wood logs Initial type test. 1.2 Description of the room heater Sheet metal stove with a front window door. The combustion chamber is insulated with vermiculite and equipped with one vermiculite baffle plate and one steel baffle plate. A grate and an ash pan are present. The amount of combustion can be regulated by two controllers. By moving the controller at the low end of the appliance the amount of secondary air (air wash) and tertiary air (holes in back wall) are adjusted simultaneously. The controller positioned in the door regulates the primary air. The flue gas connection is situated at the top of the stove. SGS Environmental Services Page 4 of 24 Reportnr.: EZKA/12/069-7

5 1.3 Abstract of the test results The following essential characteristics as defined in Annex ZA of NEN-EN 13240:2001 and NEN- EN A2:2004 have been tested with beech and fir timber (5*5 cm) as fuel and the results are as shown in the table below. Test results Essential characteristic Test fuel Fire safety Performance Beech Pass Emission of combustion products, related to 13% O 2 CO: 0.09 vol% Surface temperature Thermal output Pass 11.2 kw Energy efficiency 78.2 % Release of dangerous substances Pass Appliance Oval is an intermittent burning appliance. The appliance is not suitable for installation on a shared flue gas system. This test report with pages 1 until 12 and the annexes A until E contain the results of the type test in compliance with NEN-EN 13240:2001 and NEN-EN A2:2004. SGS Environmental Services Page 5 of 24 Reportnr.: EZKA/12/069-7

6 2 Results of assessments 2.1 Used materials, design and construction Clause Approved Production documentation 4.1 Documentation and/or drawings contain: - Specification of used materials - Nominal heat output using recommended fuels When fitted with a boiler, specification of the: - used welding process - permissible max. operating temperature, C - permissible max. operating pressure, bar - type test pressure, bar - water heating output, kw n/a General construction requirements No asbestos No hard solder, containing cadmium Thermal insulation materials: non-combustible, no health risk Design of spare parts ensures correct fitting Seals made of fire cement supported by adjacent metal surfaces n/a Integral boiler n/a Cleaning of heating surfaces - all heating surfaces accessible - easy cleaning with commercially available tools or brushes - cleaning tools provided by the manufacturer Flue spigot or socket Fitting overlap is: 25 mm for vertical connection 40 mm for horizontal connection 6 mm for inset appliances with insulating mortar infill Flue ways and cleaning tools Minimum size: - bituminous coal > 30 mm - no bituminous coals > 15 mm - easy cleaning with commercially available tools or brushes - cleaning tools provided by the manufacturer Ash pan and ash removal Volume of ash pan enough for two full charges of fuel No obstruction of combustion air n/a n/a n/a n/a n/a SGS Environmental Services Page 6 of 24 Reportnr.: EZKA/12/069-7

7 Bottom grate When removable correct assembly is ensured Capable of de-ashing without undue effort Combustion air supply Primary air inlet control: - manual or thermostatic control - adjusting control clearly visible and permanently marked - correct setting for each fuel type is identifiable - no obstruction of the air inlet control by ash or unburnt fuel Secondary air (air wash) and tertiary air inlet control: - Passage of air is not restricted by fuel Clause Approved n/a Control of flue gas n/a If flue damper is fitted: - easily operable - aperture 20 cm2 or 3% of the cross-sectional area - position of damper can be identified If draught regulator is fitted: - easily accessible for cleaning Fire doors and charging doors Large enough to fill appliance with commercially available fuels Accidental opening is prevented Positive closure Flue bypass device Easy operable Position easily identifiable n/a n/a Front fire bars deepening plate Correct assembly is ensured No accidental dislodging Solid mineral fuel and peat briquettes burning appliances n/a n/a Bottom grate and ash pan present SGS Environmental Services Page 7 of 24 Reportnr.: EZKA/12/069-7

8 2.2 Safety requirements Clause Approved Natural draught safety test 5.1 n/a Flue draught 3 Pa If Flue draught is < 3 Pa: - CO-volume 250 dm3/10 h Spillage of gas, discharge of embers 5.2 No escape of harmful gases Embers do not fall out Strength and leak tightness of boiler shells 5.3 n/a No leakage or permanent deformation after completion of the tests Temperature in fuel storage container (above ambient) 5.4 n/a Temperature < 65 K Operating tools 5.5 Operating tools provided Touched areas without tools Temperature: metal < 35 K (above ambient) porcelain < 45 K plastics, rubber, wood < 60 K n/a Temperature of adjacent combustible materials 5.6 Temperature 65 K (above ambient) (see installation and operating manual for information about clearing distances and insulation) Thermal discharge control 5.7 n/a If discharge control is part of appliance: opens at water temperature > 105 C or opens at water temperature > declared value SGS Environmental Services Page 8 of 24 Reportnr.: EZKA/12/069-7

9 2.3 Appliance instructions Instructions Clause Approved In the language of the country of intended 7.1 destination Not in contradiction to the requirements and test 7.1 results Contains the required information 7.2 (see note*) Contains the required information 7.3 (see note**) *) The following items as required in accordance with 7.2 are missing in the installation instructions: - NONE. **) The following items as required in accordance with 7.3 are missing in the operating instructions: - NONE. 2.4 Marking Clause Approved Permanently and legibly marked Readable 8 8 Durable and abrasion proof No discoloration or detachment 8 8 Contains the required information 8 (see note*) - A copy of the type shield can be found in annex C of this test report. SGS Environmental Services Page 9 of 24 Reportnr.: EZKA/12/069-7

10 3 Measurements 3.1 Test fuel specification Test fuel Moisture % Ash % Volatile matter % dry, ash free H % C % S % Hu kj/kg Size, length Beech , Fir timber , SGS Environmental Services Page 10 of 24 Reportnr.: EZKA/12/069-7

11 3.2 Performance test at nominal heat output Clause Test 1 Test 2 Test 3 Date (dd-mm-yy) Mean of 3 tests Approved Test fuel Tab. B1 Beech Beech Beech Beech Total mass kg A Setting of air slide - Primary air 0 % 0 % 0 % 0 % - Secondary air 3 mm 3 mm 3 mm 3 mm Mean flue draught Pa Mean flue gas temperature (above ambient#) K Mean CO 2 concentration % Mean CO concentration % Mean CO concentration at 13% O 2 vol% Mean CO concentration at 13% O 2 mg/m Mean CO 2 concentration during dust measurement Dust concentration mg/m 0 3 Dust concentration at 13% O 2 mg/m 0 3 NO x concentration mg/m 0 3 NO x concentration at 13% O 2 mg/m 0 3 C xh y concentration mg/m 0 3 C xh y concentration at 13% O 2 mg/m 0 3 vol% Combustion time from required combustion time Dev. h % Theoretical combustion time h A Thermal heat losses % Chemical heat losses % Heat losses due to combustible constituents in the residue % Efficiency % Mean nominal heat to space kw Theoretical heating output kw A Flue gas mass flow g/s # Room temperature during tests: 23.6 C SGS Environmental Services Page 11 of 24 Reportnr.: EZKA/12/069-7

12 3.3 Temperature safety Test Approved Date (mm-dd-yy) Test fuel A Fir timber 5*5 Total load kg A Number of loads - 10 Settings of controls for: - primary air 10% - secondary air 100% Mean flue draught Pa Ambient temperature C Max. surface temperature (above ambient) Trihedron floor* K 5.6 n/a n/a* Trihedron back wall (distance 10 cm) K n/a Trihedron side wall (distance 15 cm) K Fuel storage container K n/a Loss of fire bed 4.2 no Escape of harmful combustion gases 4.2 no Damage on the appliance caused by the test 4.2 none * Appliance must be placed on a non-combustible floor. SGS Environmental Services Page 12 of 24 Reportnr.: EZKA/12/069-7

13 Annex A Picture of the appliance SGS Environmental Services Page 13 of 24 Reportnr.: EZKA/12/069-7

14 Annex B Drawings of the appliance SGS Environmental Services Page 14 of 24 Reportnr.: EZKA/12/069-7

15 Annex C Instructions manual SGS Environmental Services Page 15 of 24 Reportnr.: EZKA/12/069-7

16 SGS Environmental Services Page 16 of 24 Reportnr.: EZKA/12/069-7

17 SGS Environmental Services Page 17 of 24 Reportnr.: EZKA/12/069-7

18 SGS Environmental Services Page 18 of 24 Reportnr.: EZKA/12/069-7

19 SGS Environmental Services Page 19 of 24 Reportnr.: EZKA/12/069-7

20 SGS Environmental Services Page 20 of 24 Reportnr.: EZKA/12/069-7

21 SGS Environmental Services Page 21 of 24 Reportnr.: EZKA/12/069-7

22 SGS Environmental Services Page 22 of 24 Reportnr.: EZKA/12/069-7

23 Annex D A copy of the type shield of the appliance SGS Environmental Services Page 23 of 24 Reportnr.: EZKA/12/069-7

24 Annex E Measurements uncertainties Sampling/analysis methods used, measuring standards and uncertainties. All measurements mentioned in this table are covered by ISO certification. Measurements marked with an asterisk are also accredited by RvA Testing under no. L-092. No. Component SGS Procedure/Standard Uncertainties 1) Determination of the particulate concentration (gravimetric) * Determination of the CO 2 concentration (nondispersive infrared) * Determination of the CO concentration (nondispersive infrared) * Determination of the C xh y concentration (equivalents of C 3H 8) (FID) ENVI/L/05, dilution tunnel EMM-006, 007, 030 conform NEN-ISO EMM-006, 008, 009, 013, 030 conform NEN-EN EMM-010, 030 conform NEN-EN < ± 14% of measured value higher than 5 mg/m 3, when fluctuations in gas flow > 10% may occur < ± 30%. < ± 8%. < ± 8%. < ± 9%. * Determination of the NO x concentration (equivalents of NO 2) (Chemiluminescent) EMM-011, 012, 030 NEN-EN conform < ± 8%. * Determination of the gas temperature (thermocouple) ENVI/L/03 conform ISO 8756, VDI/VDE 3511, VDI/VDE 3512 Blatt 2 < ± 0.75% of the measured value or ± 1.5 C (largest value) 1) The stated uncertainties refer to the 95% confidence interval (2 sigma). The stated percentages are related to the actual measurement results, unless indicated otherwise. SGS Environmental Services Page 24 of 24 Reportnr.: EZKA/12/069-7

Precision Geosynthetic Laboratories

Precision Geosynthetic Laboratories Precision Geosynthetic Laboratories CLIENT: TILE TECH PAVERS Research Name: Flexural Strength of Tile Tech Pavers Mounted on Pedestal Paver Systems for City of Los Angeles Certification Application (PGL

More information

SGS Germany GmbH. Test Report No.: H0RD0002

SGS Germany GmbH. Test Report No.: H0RD0002 SGS Germany GmbH Test Report No.: Order No.: H0RD Pages: 17 Munich, Apr 10, 2014 Client: Equipment Under Test: Nanoprotech OÜ Metal plates with different Corrosion protecting Fluids Manufacturer: Task:

More information

Installation instruction

Installation instruction Installation instruction Ci51 www.contura.eu 114 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. Ci51-CPR-150821-SE-2 PRODUCT Product type Type designation Manufacturing

More information

Installation instructions

Installation instructions Installation instructions Holetherm Double-walled flue gas discharge system (DW) 2016 All information in this release is subject to misprints. No liability is accepted for the consequences of misprints.

More information

DINAK Camiño do Laranxo, , VIGO (SPAIN) DIFLUX POLYPOPRYLENE. TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD

DINAK Camiño do Laranxo, , VIGO (SPAIN) DIFLUX POLYPOPRYLENE. TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD Rev.2 DECLARATION OF CONFORMITY AND PRODUCT DESCRIPTION 14471 Chimneys - System chimneys with plastic flue liners - Requirements and test methods Manufacturer: Product commercial name: Product description:

More information

TEST REPORT. EVALUATION CENTER Intertek Testing Services NA Inc Murphy Drive Middleton, WI 53562

TEST REPORT. EVALUATION CENTER Intertek Testing Services NA Inc Murphy Drive Middleton, WI 53562 TEST REPORT REPORT NUMBER: 102741836MID-001bR2 REPORT DATE: October 24, 2016 REVISED REPORT DATE: August 7, 2017 REVISED REPORT DATE: August 11, 2017 REVISED REPORT DATE: September 6, 2017 EVALUATION CENTER

More information

INDUSTRIAL BOILER. Moving step grate Under feed firing HPKI-R HPKI-K

INDUSTRIAL BOILER. Moving step grate Under feed firing HPKI-R HPKI-K BOILER Moving step grate Under feed firing HPKI-R 180-0 HPKI-K 180-0 INDUSTRIAL BOILER HPKI - R 180-0 - Moving step grate air-cooled The high-performance boiler is produced as a stress-free welded construction.

More information

Installation instructions

Installation instructions Installation instructions Holetherm Single-walled flue gas discharge system (EW) 2016 All information in this release is subject to misprints. No liability is accepted for the consequences of misprints.

More information

Environment Protection Engineering. POLLUTANT CONCENTRATIONS FROM A 15 kw HEATING BOILER SUPPLIED WITH SUNFLOWER HUSK PELLETS

Environment Protection Engineering. POLLUTANT CONCENTRATIONS FROM A 15 kw HEATING BOILER SUPPLIED WITH SUNFLOWER HUSK PELLETS Environment Protection Engineering Vol. 38 2012 No. 1 MAREK JUSZCZAK* POLLUTANT CONCENTRATIONS FROM A 15 kw HEATING BOILER SUPPLIED WITH SUNFLOWER HUSK PELLETS Sunflower husk pellets were fired in a channel

More information

Product catalogue. Compliant with EN norm

Product catalogue. Compliant with EN norm Product catalogue Compliant with EN 303-5 norm Eco-friendly technologies Biomass the fuel of the future Biomass is a renewable energy source composed of natural organic material produced by plant photosynthesis.

More information

Appendix VIII: Determination of chimney heights

Appendix VIII: Determination of chimney heights Appendix VIII: Determination of chimney heights 181 Regional Air Quality Plan for Taranaki 182 Regional Air Quality Plan for Taranaki Appendix VIII: Determination of stack heights and boiler operation

More information

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE ROCKWOOL B.V. / ROCKPANEL Group Konstruktieweg 2 NL-6045 JD Roermond www.rockpanel.com DECLARATION OF PERFORMANCE No. 0764-CPR-0249 UK vs01 1. Unique identification code of the product-type: ROCKPANEL

More information

Ventum Series. The new Generation Wood Gasification Boilers. Europe s Fastest Selling Wood Gasification Boiler.

Ventum Series. The new Generation Wood Gasification Boilers. Europe s Fastest Selling Wood Gasification Boiler. Ventum Series The new Generation Wood Gasification Boilers Europe s Fastest Selling Wood Gasification Boiler. The New Generation Ventum Series leaps forward in gasification technology making them the fastest

More information

Experimental Study on Combustion of Biomass in a Boiler with Gasification

Experimental Study on Combustion of Biomass in a Boiler with Gasification Experimental Study on Combustion of Biomass in a Boiler with Gasification TĂNASE PANAIT, GHEORGHE CIOCEA, ION ION Thermal Systems and Environmental Engineering Department Dunarea de Jos University of Galati

More information

SCHNEIDER-KESSEL BERLIN

SCHNEIDER-KESSEL BERLIN SCHNEIDER-KESSEL BERLIN STEAM BOILER and HOT WATER BOILER WASTE HEAT RECOVERY BOILER - Series AHK GENERAL Waste Heat Recovery boilers of Series AHK are steam generators in special smoke tube design to

More information

De Montfort Mark 7 Incinerator (Flatpack)

De Montfort Mark 7 Incinerator (Flatpack) De Montfort Mark 7 Incinerator (Flatpack) Introduction This design is specially for those occasions when a large number of incinerators are to be built at one location and transported to the places where

More information

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board Member of Kiwa Nederland B.V. www.eota.eu Sir Winston Churchilllaan 273 NL-2288 EA Rijswijk Postbus 70 NL-2280 AB Rijswijk Tel.: +31 (0)88 998 44 00 Fax: +31 (0)88 998 44 20 E-mail: info@kiwa.nl European

More information

HILTI CP 674 Cavity Closure For Rainscreen / Cladding Systems

HILTI CP 674 Cavity Closure For Rainscreen / Cladding Systems Data Sheet HILTI CP 674 Cavity Closure For Rainscreen / Cladding Systems The enclosed pages are taken from the Hilti Firestop Systems Manual Edition April 2011 Supported by additional standard details

More information

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS ENCLOSURE MODEL 90566400 FOR INSERT MODEL 5660NA And ENCLOSURE MODEL 90566000 FOR INSERT MODEL 5660 STANDARD KEEP THESE INSTRUCTIONS FOR FUTURE USE

More information

Amendment BRL K17504/02

Amendment BRL K17504/02 Amendment BRL K17504/02 DRAFT vulcanised rubber products for cold and hot drinking water applications Date ammendment dd-mm-jjjj Validated by Kiwa Board of Experts Water Chain (CWK) on dd-mm-jjjj. The

More information

Installation Instructions

Installation Instructions Installation Instructions SAVE THESE INSTRUCTIONS Please read this entire manual before you install and use your room heater. Failure to follow instructions may result in property damage, bodily injury,

More information

Medium Combustion Plant Directive Planning Fitness for Compliance

Medium Combustion Plant Directive Planning Fitness for Compliance Medium Combustion Plant Directive Planning Fitness for Compliance Sharon Kuligowski Managing Director Dunphy Combustion Ltd 1 what fate for the Medium Combustion Plant Directive? emissions limit values

More information

For building inspections

For building inspections Thermal imaging basics For building inspections An infrared building inspection guidebook Fluke Thermal Imaging Infrared Building Inspection Guidebook Contents Page Section 3 4 5 6 9 10 12 Introduction

More information

ARGOS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2. PRE-INSTALLATION 3. INSTALLATION 4. OPERATION 5. TESTING. Keep for future use

ARGOS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2. PRE-INSTALLATION 3. INSTALLATION 4. OPERATION 5. TESTING. Keep for future use ARGOS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 5 4. OPERATION 9 5. TESTING Keep for future use 10 1. TECHNICAL DATA WEIGHT AND DIMENSIONS: Dimensions Firebox W531

More information

Pipe Joints. Requirements and Test Methods. VdS-Guidelines for water extinguishing systems. VdS en. VdS en : (01)

Pipe Joints. Requirements and Test Methods. VdS-Guidelines for water extinguishing systems. VdS en. VdS en : (01) VdS-Guidelines for water extinguishing systems VdS 2100-6en Requirements and Test Methods Reproduction prohibited even for internal use VdS 2100-6en : 2004-01 (01) Publisher and Publishing house: VdS Schadenverhütung

More information

PHAROS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2. PRE-INSTALLATION 3. INSTALLATION 4. OPERATION 5. TESTING. Keep for future use

PHAROS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2. PRE-INSTALLATION 3. INSTALLATION 4. OPERATION 5. TESTING. Keep for future use PHAROS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 5 4. OPERATION 9 5. TESTING Keep for future use 10 1. TECHNICAL DATA WEIGHT AND DIMENSIONS: Dimensions Firebox W531

More information

Dunbrik A1 Concrete Flue Liners

Dunbrik A1 Concrete Flue Liners Dunbrik A1 Concrete Flue Liners System Guide Firebelly stove FB2 woodburner in pewter domestic flue & chimney systems Certificate No.FM24104 Benefits of a Chimney A chimney adds appeal to a house A real

More information

Smoke Control Damper ESAM Instructions for installation, operation and maintenance 10/2014

Smoke Control Damper ESAM Instructions for installation, operation and maintenance 10/2014 Instructions for installation, operation and maintenance 0/204 General The rectangular smoke control damper ESAM is specially designed for use in multi fire-compartment applications as a closing or opening

More information

Buderus SB745WS/1550 Stainless Steel Condensing Boiler

Buderus SB745WS/1550 Stainless Steel Condensing Boiler Stainless Steel Condensing Boiler Engineering Submittal Sheet Boiler Components R Engineering Specifications The boiler(s) shall have a full three pass fire tube design to allow complete combustion of

More information

ISO 1171 INTERNATIONAL STANDARD. Solid mineral fuels Determination of ash. Combustibles minéraux solides Détermination des cendres

ISO 1171 INTERNATIONAL STANDARD. Solid mineral fuels Determination of ash. Combustibles minéraux solides Détermination des cendres INTERNATIONAL STANDARD ISO 1171 Fourth edition 2010-06-15 Solid mineral fuels Determination of ash Combustibles minéraux solides Détermination des cendres Reference number ISO 1171:2010(E) ISO 2010 PDF

More information

Exceptionally strong and flexible Proven durability and long life 20 year warranty CE marked and HETAS approved

Exceptionally strong and flexible Proven durability and long life 20 year warranty CE marked and HETAS approved Exceptionally strong and flexible Proven durability and long life 20 year warranty CE marked and HETAS approved Chimneys Liners Renewables The trusted name for Multifuel flexible liners for over 30 years

More information

Thermocouple for Flue Gas Temperature Measurements,

Thermocouple for Flue Gas Temperature Measurements, Electrical Temperature Measurement Thermocouples for Flue Gas Temperature Measurements Model TC81 with Thermowell Model TW81 WIKA Data Sheet TE 65.81 Applications Blast furnaces, air heaters Red-heat and

More information

Air flue duct for use with ecotec boilers

Air flue duct for use with ecotec boilers For the installer Flue installation instructions Air flue duct for use with ecotec boilers Concentric System Ø 80/5 (Galvanized steel air duct/plastic flue duct) GB Contents Notes on the documentation

More information

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 1 Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) PRODUCT DESCRIPTION This Detail Sheet relates to Xtratherm Thin-R Partial Fill Cavity Wall Board, as

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation This annex is valid from: 16-08-2017 to 01-08-2020 Replaces annex dated: 23-05-2016 Vlamoven 41 6826 TM Arnhem The Netherlands Location(s) where activities are performed under accreditation Head Office

More information

Fireplace. Opening. Old. Opening up an old fireplace is like striking gold in your very own home.

Fireplace. Opening. Old. Opening up an old fireplace is like striking gold in your very own home. Opening up an Opening up an old fireplace is like striking gold in your very own home. In addition to a glowing, warmer, more welcoming living room, you are creating a much healthier and more invigorating

More information

Draft for comments only Not to be cited as East African Standard

Draft for comments only Not to be cited as East African Standard CD/K/055-5:2009 ICS 23.040.20; 23.040.45; 91.140.60; 93.025 EAST AFRICAN STANDARD Plastics piping systems Polyethylene (PE) pipes and fittings for water supply Part 5: Fitness purpose of the system EAST

More information

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00 PMA 31-G English 1 Information about the documentation 1.1 About this documentation Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and

More information

Wood Chip and Pellet Boilers

Wood Chip and Pellet Boilers Wood Chip and Pellet Boilers www.froeling.com Heating with wood chips and pellets For more than 50 years Froling has specialised in the efficient use of wood as a source of energy. Today the name Froling

More information

HILTI CP 617 Intumescent acoustic putty pad

HILTI CP 617 Intumescent acoustic putty pad Data Sheet HILTI CP 617 Intumescent acoustic putty pad The enclosed pages are taken from the Hilti Firestop Systems Manual Edition April 2011 Supported by additional standard details For Material Safety

More information

MP-400. The most thermally efficient, robust and reliable medical incinerators on the market. Simply Built Better!

MP-400. The most thermally efficient, robust and reliable medical incinerators on the market. Simply Built Better! The most thermally efficient, robust and reliable medical incinerators on the market Simply Built Better! Specifically designed for medical waste. MP-400 The MP medical hot hearth Incinerators designed

More information

Quality assurance of automated measuring systems

Quality assurance of automated measuring systems InfoMil Factsheet L40-7C AIR Quality assurance of automated measuring systems Continuous measurements This factsheet is part of the L40 series Measurement of air emissions. L40 consists of a manual that

More information

INTHUU MEASUREMENTS CC

INTHUU MEASUREMENTS CC INTHUU MEASUREMENTS CC VAT REG NO.: 4960254359 REG NO.: 2009/190265/23 P.O. Box 14769 Bredell, 1623 Plot 2/410 Seventh Road Bredell A/H, Kempton Park, 1619 Tel: +27 (0)82 572-2380 Fax: +27 (0)86 659-2231

More information

Sprinkler Identification Numbers (SINs)

Sprinkler Identification Numbers (SINs) Worldwide Contacts www.tyco-fire.com Model 2.8 K-factor Combustible Concealed Space Sprinklers Specific Application, Upright General Description The Model Combustible Concealed Sprinklers are fast response,

More information

All boilers with touch screens. Log Wood

All boilers with touch screens. Log Wood Therminator II_Stückholz_EN_03-2013_Therminator II_03_2006_ORIGINAL.qxd 21.03.2013 08:30 Seite 1 Wood gasification boiler II touch Log Wood l Gasifier technology Choose the right fuel Make the shrewd decision

More information

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems INTERNATIONAL STANDARD ISO 10239 Second edition 2008-02-15 Small craft Liquefied petroleum gas (LPG) systems Petits navires Installations alimentées en gaz de pétrole liquéfiés (GPL) Reference number ISO

More information

Installation in ceilings

Installation in ceilings Installation instructions EI90 BET Cable Boxes "System Wichmann" ceiling 350 mm depth, rectangular ETA 13/0902 BET Cable Box to be poured in the concrete» Technical datasheet - page 4-7 Installation in

More information

Fine particle measuring system

Fine particle measuring system Data sheet testo 380 Fine particle measuring system testo 380 The innovative complete solution In combination with testo 330-2 LL, the innovative complete solution for solid fuels, oil and gas systems.

More information

Alliance for Water Stewardship Assessment Report

Alliance for Water Stewardship Assessment Report Alliance for Water Stewardship Assessment Report Prepared for DANPER TRUJILLO S.A.C. Prepared by: SGS SGS Ref.: PE-WAT-009 Version: 1 Date: 15 September 2017 This is a controlled document, which is subject

More information

ISO INTERNATIONAL STANDARD. Fire resistance of timber door assemblies Method of determining the efficacy of intumescent seals

ISO INTERNATIONAL STANDARD. Fire resistance of timber door assemblies Method of determining the efficacy of intumescent seals INTERNATIONAL STANDARD ISO 12472 First edition 2003-05-15 Fire resistance of timber door assemblies Method of determining the efficacy of intumescent seals Résistance au feu d'assemblages de portes en

More information

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating

More information

European Technical Approval No. ETA-12/0056

European Technical Approval No. ETA-12/0056 SINTEF Building and Infrastructure P.O.Box 124 Blindern N-0314 Oslo Tel. 47 22 96 55 55 Fax 47 22 69 94 38 Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 11140-3 Second edition 2007-03-15 Sterilization of health care products Chemical indicators Part 3: Class 2 indicator systems for use in the Bowie and Dick-type steam penetration

More information

testo 350 M testo 350 XL

testo 350 M testo 350 XL Complex thermal applications - Easy measurements! Portable, modular flue gas analyser for industrial processes testo 350 M testo 350 XL Easily upgraded with additional analysis boxes for more measurement

More information

MP-300. The most thermally efficient, robust and reliable medical incinerators on the market. Simply Built Better!

MP-300. The most thermally efficient, robust and reliable medical incinerators on the market. Simply Built Better! The most thermally efficient, robust and reliable medical incinerators on the market Simply Built Better! Specifically designed for medical waste. MP-300 The MP medical hot hearth Incinerators The Addfield

More information

5. Boiler Plants for farms

5. Boiler Plants for farms 5. Boiler Plants for farms The present use of straw firing in agriculture expanded heavily due to the energy crisis in the 1970s with the following subsidy schemes and easy terms concerning depreciation

More information

HILTI CP 657 Firestop Brick

HILTI CP 657 Firestop Brick Data Sheet HILTI CP 657 Firestop Brick The enclosed pages are taken from the Hilti Firestop Systems Manual Edition April 2011 Supported by additional standard details For Material Safety data sheets visit

More information

S T O V E S A N D S U R R O U N D S

S T O V E S A N D S U R R O U N D S S T O V E S A N D S U R R O U N D S This brochure features our range of multifuel and woodburning stoves pictured in a selection of fireplaces taken from our collection. Offering a choice of traditional

More information

Pacifyre MK II Fire Sleeves

Pacifyre MK II Fire Sleeves Pacifyre MK II Fire Sleeves Fire, smoke and sound barrier Fire resistant for 240 minutes Easy to install Wide range of applications Conforms to BS standards Easy self installation in accordance with the

More information

KAZAN: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 6 4. OPERATION TESTING 11. Keep for future use

KAZAN: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 6 4. OPERATION TESTING 11. Keep for future use KAZAN: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 6 4. OPERATION 10 5. TESTING 11 Keep for future use 1. TECHNICAL DATA WEIGHT AND DIMENSIONS: Dimensions Firebox W642

More information

FPD190 Differential pressure restriction orifice plates

FPD190 Differential pressure restriction orifice plates Data sheet DS/FPD190 EN FPD190 Differential pressure restriction orifice plates Limits the flowrate or reduces the pressure of liquids, gases and steam Measurement made easy Orifice plate for flow restriction

More information

BIO-Europe Spring 2018 DB Schenker Fairs & Events Official logistics freight forwarder of RAI Amsterdam

BIO-Europe Spring 2018 DB Schenker Fairs & Events Official logistics freight forwarder of RAI Amsterdam DB Schenker Logistics Nederland BU Fairs & Events Revision 01 07/2015 FN BIO-Europe Spring 2018 DB Schenker Fairs & Events Official logistics freight forwarder of RAI Amsterdam Dear Exhibitor, RAI Amsterdam

More information

6515 Series Measurement of CO2 in Flue Gases. A simple Katharometer-type measuring system for CO2 in flue gases as a guide to combustion efficiency

6515 Series Measurement of CO2 in Flue Gases. A simple Katharometer-type measuring system for CO2 in flue gases as a guide to combustion efficiency Data sheet DS/6515 EN Rev. C 6515 Series Measurement of CO2 in Flue Gases A simple Katharometer-type measuring system for CO2 in flue gases as a guide to combustion efficiency Fuel Economy and CO 2 Measurements

More information

Title: The Fire Resistance Performance of PRT and PRC, Side and Centre-Opening, Vandal Resistant, Lift Landing Doorsets. WF Assessment Report No:

Title: The Fire Resistance Performance of PRT and PRC, Side and Centre-Opening, Vandal Resistant, Lift Landing Doorsets. WF Assessment Report No: assessment report Title: The Fire Resistance Performance of PRT and PRC, Side and Centre-Opening, Vandal Resistant, Lift Landing Doorsets WF Assessment Report No: 183968A Prepared for: Klefer SA Kilkis

More information

HAKA 63/51W, 63/51WI A + Technical data

HAKA 63/51W, 63/51WI A + Technical data HAKA 63/51W, 63/51WI A + Operation when directly connected to chimney HAKA 63/51 W HAKA 63/51 WI Tested according to EN 13229 EN 13229 Nominal heat power / Power absorbed to water 14,5 / 10 kw 14,5 / 11,3

More information

ORDINANCE NO. An ordinance amending Chapter 59, Dallas Energy Conservation Code, of the Dallas City

ORDINANCE NO. An ordinance amending Chapter 59, Dallas Energy Conservation Code, of the Dallas City 12-19-16 ORDINANCE NO. 3 0 32 5 An ordinance amending Chapter 59, Dallas Energy Conservation Code, of the Dallas City Code, as amended; adopting with certain changes the 2015 Edition of International Energy

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 13199 First edition 2012-10-15 Stationary source emissions Determination of total volatile organic compounds (TVOCs) in waste gases from non-combustion processes Nondispersive

More information

SI T T FST

SI T T FST SI 440-600-700-700T-780-780T-900-1100 Freestanding TAPER TOP Open Fire - Wood Burner Installation Instructions Note: FLUE SYSTEMS Casing. Flue System may require to be Doubled Lined to Comply. Ref ASNZS:2918:2001

More information

Product Information Sheet

Product Information Sheet Product Information Sheet Product Name ISOVER Spacesaver Roll A mineral wool roll for domestic attic floors. Rolls pre-perforated to 3 x 386cm and 2 x 580cm widths to fit between common joist spacings.

More information

General Product & Quality Specification

General Product & Quality Specification Date: 03/04/2017 Revision: 11 General Product & Quality Specification Flush Veneer and Durador Doors Introduction: Portfolio Veneer Match and Veneered flush doors are designed for internal use only, and

More information

Microgeneration Certification Scheme: MCS 008

Microgeneration Certification Scheme: MCS 008 Microgeneration Certification Scheme: MCS 008 Product Certification Scheme Requirements: Biomass Issue 2.0 This Microgeneration Installation Standard is the property of Department of Energy and Climate

More information

Introduction to Building Envelope Analysis

Introduction to Building Envelope Analysis Western Technical College 10481109 Introduction to Building Envelope Analysis Course Outcome Summary Course Information Description Career Cluster Instructional Level Total Credits 3.00 Total Hours 90.00

More information

ISO INTERNATIONAL STANDARD. Metallic materials Tensile testing Part 2: Method of test at elevated temperature

ISO INTERNATIONAL STANDARD. Metallic materials Tensile testing Part 2: Method of test at elevated temperature INTERNATIONAL STANDARD ISO 6892-2 First edition 2011-02-15 Metallic materials Tensile testing Part 2: Method of test at elevated temperature Matériaux métalliques Essai de traction Partie 2: Méthode d'essai

More information

HIGH/INDUCED DRAUGHT ZIGZAG FIRING TECHNOLOGY

HIGH/INDUCED DRAUGHT ZIGZAG FIRING TECHNOLOGY INITIATIVES BRIKCS HIGH/INDUCED DRAUGHT ZIGZAG FIRING TECHNOLOGY INTRODUCTION AND HISTORY, GEOGRAPHICAL DISTRIBUTION High/Induced Draught Zigzag Firing kiln is a continuous, cross draught, moving fire

More information

Woodstove Retrofit Efficacy Testing OMNI Report# 0323WS001N. Prepared for:

Woodstove Retrofit Efficacy Testing OMNI Report# 0323WS001N. Prepared for: Woodstove Retrofit Efficacy Testing OMNI Report# 0323WS001N Prepared for: Dr. Phillip Swartzendruber Puget Sound Clean Air Agency 1904 Third Avenue Suite 105 Seattle, WA 98101 Prepared by: OMNI-Test Laboratories,

More information

Biomass Boiler Emission Abatement Technologies. Simon Wakefield

Biomass Boiler Emission Abatement Technologies. Simon Wakefield Biomass Boiler Emission Abatement Technologies Simon Wakefield simon.wakefield@hwenergy.co.uk About Us Established in 2003 Specialise only in biomass heating Team of 50 staff Design & engineering led company

More information

Industrial flue gas probes. Instruction manual

Industrial flue gas probes. Instruction manual Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...

More information

Rediflow Concrete Gas Flue System

Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow the complete gas flue block system Red Bank s range of Rediflow pre-cast concrete gas flue block system manufactured to BS EN

More information

CLA. Compact sound attenuator for circular ducts QUICK FACTS

CLA. Compact sound attenuator for circular ducts QUICK FACTS Compact sound attenuator for circular ducts QUICK FACTS Extremely low installation height. Excellent sound attenuation Mineral wool covered with special polyester woven fabric. Tightness Class D Low pressure

More information

DRAFT UGANDA STANDARD

DRAFT UGANDA STANDARD DRAFT UGANDA STANDARD DUS 1674 First Edition 2017-mm-dd Surface polish specification Reference number DUS 1674: 2017 UNBS 2017 DUS1674: 2017 Compliance with this standard does not, of itself confer immunity

More information

PLASTIC OIL 330 SAFETY DATA SHEET 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING 2. HAZARDS IDENTIFICATION

PLASTIC OIL 330 SAFETY DATA SHEET 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING 2. HAZARDS IDENTIFICATION Date of issue: 01.03.2012 Sonneborn Refined Products B.V. urges the recipient of this Safety Data Sheet to study it carefully to become aware of hazards, if any, of the product involved. In the interest

More information

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION Insulation A4/6 PSW AW1690 Issue 4 Apr 2014 Permifloor WATER-PERMEABLE UNDERFLOOR INSULATION Helps improve energy efficiency 2-in-1 insulation and moisture management solution Fibre-free, non-allergenic,

More information

CEN Keymark Scheme Rules for Thermostatic Radiator Valves. 2 nd Edition

CEN Keymark Scheme Rules for Thermostatic Radiator Valves. 2 nd Edition CEN Keymark Scheme Rules for Thermostatic Radiator Valves 2 nd Edition Content Foreword... 3 Introduction... 3 1 Scope... 4 2 References... 4 3 Terms and Definitions... 4 4 Application... 5 4.1 Product

More information

About asbestos. About asbestos

About asbestos. About asbestos About asbestos About asbestos Contact customer services on 01225 715 715 About asbestos This leaflet explains what asbestos is, how it is being managed in homes and what you can do to stay safe if it is

More information

1/58 Components of solar systems

1/58 Components of solar systems 1/58 Components of solar systems storage heat exchangers safety and protection devices air vents, check valve control & measurement Thermosiphon circulation system 2/58 circulation induced by buoyancy

More information

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION Insulation A4/6 TB055W AW2244 Issue 6 Oct 2017 WHITE-FACED THERMO REFLECTIVE INSULATION Innovative cross-linked closed cell insulation core 3-in-1 Insulation, vapour barrier and radiant barrier Helps achieve

More information

Asbestos and Lead Considerations in Construction Projects. Sean Purcer Senior Consultant Anthony Price Senior Consultant

Asbestos and Lead Considerations in Construction Projects. Sean Purcer Senior Consultant Anthony Price Senior Consultant Asbestos and Lead Considerations in Construction Projects Sean Purcer Senior Consultant Anthony Price Senior Consultant Who We Are History Founded in 1990 by Environmental, Health and Safety (EHS) managers

More information

Performance Standards for Indicative Ambient Particulate Monitors Environment Agency July 2012 Version 2

Performance Standards for Indicative Ambient Particulate Monitors Environment Agency July 2012 Version 2 Performance Standards for Indicative Ambient Particulate Monitors Environment Agency July 2012 Version 2 Foreword We set up our Monitoring Certification Scheme (MCERTS) to provide a framework of standards

More information

Fire Barrier Duct Wrap 615+

Fire Barrier Duct Wrap 615+ Fire Barrier Duct Wrap 615+ Duct Wrap Fire Protection System for Commercial Kitchen Grease and Ventilation Air Ducts Product Data Batts and blankets for use in fire resistive duct assemblies see UL fire

More information

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS BuildingName The Description of the Project P00000000 0000 DOCUMENTS Title Page Table of Contents Instruction to Bidders Form of Proposal Equal Opportunity Statement Form of Guarantee Supplemental General

More information

a difficult challenge when trying to achieve effective coverage within a shallow space. The Model CC1 Combustible

a difficult challenge when trying to achieve effective coverage within a shallow space. The Model CC1 Combustible Worldwide Contacts www.tyco-fire.com Model CC1 2.8 K-factor Combustible Concealed Space Sprinklers Specific Application, Upright General Description The Model CC1 Combustible Concealed Sprinklers are fast

More information

Buderus SB625WS/640 Stainless Steel Condensing Boiler

Buderus SB625WS/640 Stainless Steel Condensing Boiler Stainless Steel ondensing Boiler Engineering Submittal Sheet Boiler omponents R Engineering Specifications The boiler(s) shall have a full three pass fire tube design to allow complete combustion of the

More information

Michigan Energy Code Training and Implementation Program

Michigan Energy Code Training and Implementation Program Michigan Energy Code Training and Implementation Program 1.0 Hour Advanced Program Course Number 16201 Residential Energy Air Sealing School of Planning, Design & Construction Michigan State University

More information

Pellet heating system

Pellet heating system HDG Pelletmaster 15 HDG Pelletmaster 25 Heating systems for wood Products from Bavaria Germany Pellet heating system Heating with wood convenient and innovative Heating with pellets What makes heating

More information

BioMatic. Forward-looking and energy efficient Biomass heating. Local heating / district heat network

BioMatic. Forward-looking and energy efficient Biomass heating. Local heating / district heat network Forward-looking and energy efficient Biomass heating Local heating / district heat network Innovative heating with the unbeatable compact BioMatic system for wood chips or pellets BioMatic Advantages of

More information

TEST REPORT SCOPE: EMISSIONS, EFFICIENCY AND OUTPUT FUEL: EPA TEST FUEL (CRIBS) TEST STANDARD: EPA MODEL: S245E WOOD STOVE

TEST REPORT SCOPE: EMISSIONS, EFFICIENCY AND OUTPUT FUEL: EPA TEST FUEL (CRIBS) TEST STANDARD: EPA MODEL: S245E WOOD STOVE TEST REPORT SCOPE: EMISSIONS, EFFICIENCY AND OUTPUT FUEL: EPA TEST FUEL (CRIBS) TEST STANDARD: EPA MODEL: S245E WOOD STOVE Notice to reader: Our S245E wood stove was tested as part of our 1.3 Series (S244)

More information

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D PIPEWORK INSULATION 14/10-2014 Page 1 of 10 Pipework Insulation Rev D Contents INTRODUCTION General Scope Surfaces to be Insulated Pumps, Turbines etc Performance Minimum Pipe Insulation Thickness Physical

More information

Tehnical Data Sheet Astro HS FM Compound. UIC of product-type: HSFMC CPR-JA5013 ETA-14/0047. ETAG 026-Part 1 ETAG 026-Part 2

Tehnical Data Sheet Astro HS FM Compound. UIC of product-type: HSFMC CPR-JA5013 ETA-14/0047. ETAG 026-Part 1 ETAG 026-Part 2 1121 Astroflame Fireseals Ltd Unit 8 The I O Centre 14 1121-CPR-JA5013 ETA-14/0047 ETAG 026-Part 1 ETAG 026-Part 2 FM Compound see ETA-14/0047 for relevant characteristics APPROVED CF613 EN13501-2 EN1366-3:2009

More information

Space product assurance

Space product assurance Space product assurance Dry heat bioburden reduction for flight hardware ECSS Secretariat ESA-ESTEC Requirements & Standards Division Noordwijk, The Netherlands Foreword This Standard is one of the series

More information

ISO INTERNATIONAL STANDARD. Series 1 freight containers Specification and testing Part 2: Thermal containers

ISO INTERNATIONAL STANDARD. Series 1 freight containers Specification and testing Part 2: Thermal containers INTERNATIONAL STANDARD ISO 1496-2 Fifth edition 2008-07-15 Series 1 freight containers Specification and testing Part 2: Thermal containers Conteneurs de la série 1 Spécifications et essais Partie 2: Conteneurs

More information