ULTRAFILTRATION UNIT POD - USER INFORMATION GUIDE & DATA SHEET. Cluster and Small Community Safe Water Filtra4on unit SPOD.

Size: px
Start display at page:

Download "ULTRAFILTRATION UNIT POD - USER INFORMATION GUIDE & DATA SHEET. Cluster and Small Community Safe Water Filtra4on unit SPOD."

Transcription

1 ULTRAFILTRATION UNIT POD - USER INFORMATION GUIDE & DATA SHEET Cluster and Small Community Safe Water Filtra4on unit SPOD

2 A genuine gamechanger technology to meet the UN- SDG s challenge SYSTEM OVERVIEW About the SkyHydrant POD Assembling the SkyHydrant POD Installation of the SkyHydrant POD Commence Use of the SkyHydrant POD Cleaning the SkyHydrant POD Feed Water Suitability...11 Water Quality Maintenance Storage of the SkyHydrant POD 13 Performance Monitoring Technical Data...15

3 ULTRAFILTRATION UNIT OVERVIEW AND OPERATING INSTRUCTIONS POD The POD is a multi function unit designed for small clusters in multiple configurations to produce safe drinking water without the need for process chemicals, power and consumables. 1 ABOUT THE SKYHYDRANT POD Did you know SkyHydrants are used for a wide range of applications and configurations to supply safe water to remote and rural communities. They can treat many of the commonly compromised sources of surface and ground water. The patented cleaning process ensures the system operates continuously using a simple manual clean procedure easily initiated by non-technical persons. from raw water supply Vent WALL MOUNT BRACKET RAW WATER SOURCES: The unique ultrafiltration process enables the SkyHydrant to directly produce quality safe drinking from various raw water sources using low water pressure (1-2 metres head) without complicated technical procedures. The World Health Organisation (WHO) classifies the ultrafiltration technology used in the SkyHydrant for virtual complete removal of pathogens, dirt and turbidity for potable water. The system is not designed to removes salts or chemicals and it always suggested to undertake a complete investigation and analysis of the proposed source water PATENTED SHAKE & FLUSH CLEANING: Regular cleaning is necessary and takes a minute to complete. It is essential to prevent the filter module becoming clogged. A handle is used to move the POD back and forth to shake clean the internal filter before flushing away the contaminants. UNIQUE FILTER MODULE: The SkyHydrant POD does not use chemicals or power for operation. It does not need to be accessed internally for cleaning. The PvdF module life is many years with correct cleaning and maintenance. HOW AND WHERE IT CAN BE USED: The SkyHydrant POD is positioned as a new disruptive technology for emerging markets that critically challenges traditional outdated notions. It Is positioned to flexibly fulfill UN-SDG s potable water emergency, NGO and community water needs. It empowers the users with options, such as fixed and mobile service scenarios, that are truly unlimited and wide ranging to BOP user groups. HANDLE Use to shake clean Ball valve to drainage to drinking taps SkyHydrantPOD TYPICAL APPLICATIONS Distributed off-grid SDG water supply Community and small-scale cluster systems Remote and rural water for developing users Small mobile safe water vendors (MWV s) Social entrepreneur - Safe Water Kiosks Emergency and temporary water supplies Clinics, schools and hospitals SKYHYDRANT POD - USER GUIDE & DATA SHEET 3

4 2 GET STARTED : ASSEMBLING THE SKYHYDRANT POD Unpack the SkyHydrantPOD and remove plugs from each end and connect fittings as shown in The accompanying diagrams. Note: the filter module inside the SkyHydrantPOD must remain enclosed in a wet or moist environment to prevent dry out which would damage the module. UNPACK POD UNIT REMOVE PLUGS FROM EACH END CONNECT T1,T2,T3 & T4 Ball valve SKYHYDRANT POD - USER GUIDE & DATA SHEET 4

5 3 INSTALLING THE SKYHYDRANT POD For fixed installations, select a secure undercover location sheltered from sun and rain. The site should include access to a disposal area for backwash water. Mobile vendors will have a portable dispenser rig. The SkyHydrant POD requires no power to operate. It relies on the flow of water from gravity or low pressure pump. Raw water flows with a typical water head pressure of between 2 metres and maximum 4 metres (20kPa to 40kPa or 3psi to 6psi). The fixed installations, proceed as follows: MOUNT ON WALL WITH WALL BRACKET Attach Wall Bracket or suspend the SkyHydrant POD from an overhead support Use fasteners to screw the wall bracket in position and mount the SkyHydrant POD. CONNECT HOSES Connect Plumbing Fittings All outlets use 15mm (1/2 ) BSP connectors and quick connect fittings. FULLY ASSEMBLED Setup Ancillary Connections Connect hoses and fittings to allow the SkyHydrant POD to function i.e. taps, pipes, tanks, pumps or other equipment. Screws from raw water supply Vent from raw water supply Vent WALL MOUNT BRACKET HANDLE Use to shake And clean WALL MOUNT BRACKET HANDLE Use to shake and clean WALL MOUNT BRACKET Ball valve Ball valve to drinking taps to drinking taps to drainage to drainage SKYHYDRANT POD - USER GUIDE & DATA SHEET 5

6 CONVENTIONAL SKYHYDRANT SETUP OPTIONS A number of established setup options are available. A popular method is to utilise an existing water tankstand infrastructure and install the POD. If installing as new, then the usual option is to pump raw water (using mechanical or hand pump) to a header tank located on a 3 meter high tank-stand and allow The water to gravity feed through the SkyHydrant. Filtrate can flow directly to individual containers/users to be collected in a lower drinking water tank. (Suggestion is for a 1 meter high tank stand.) Note : For more information about setup see document: SkyHydrant Setup and Equipment Options. HEADER TANK FILTRATE TANK SHELTER SHED TAPS screened foot valve PUMP fuel, electric or hand pump TANK STAND PRE-FILTER optional (see notes) SKYHYDRANT ULTRAFILTRATION TANK STAND DRINKING WATER OUTLET RAW WATER SOURCE dam, river, stream, pond, lake or well Example of SkyHydrant Setup with Pump & Gravity Flow SKYHYDRANT EQUIPMENT OPTIONS FOR CLUSTER INSTALLATIONS For more information see document: SkyHydrant Setup and Equipment Options. SkyHydrants may need to be configured with additional equipment and components to operate. The actual type of equipment needed depends on the intended application, context and available local resources When planning a large capacity SkyHydrant POD installation, the following should be considered: 1) 2) 3) 4) 5) Water Pressure: Water Levels: Pre-filter Devices: Post-filtration Treatment: Fittings & Components: Avoiding excessive pressure, which may damage the SkyHydrant. Keeping water tanks full without overflowing. Try to avoid clogging SkyHydrants or other equipment with contaminants. Further water treatment may be needed in some cases. Typical Ancillaries needed ie, water pipes, hoses, connectors, tanks, pump, etc. Overall design configurations are outlined in more detail below: 1) Controlling Water Pressure SkyHydrants are designed to operate on low differential water pressure not exceeding 30 kpa this prevents the SkyHydrant filter fibres being damaged. Under low water pressure conditions, contaminants build up as a biofilm layer around the individual filter fibres. This can be easily removed during the shake & clean process. Higher feed pressure should be avoided as contaminants may lodge stuck in the filter fibers, eventually blocking water flow and damaging the unit. Water pressure can be controlled by a gravity flow system or by using a pressure control device (PCD). Gravity flow is always recommended and is a simple and consistent method to control feed pressure through the POD. Also adjusting the pipe inlet and outlet height is an effective means of controlling the water pressure. The following diagram details the recommended maximum gravity flow water pressures when constructing a POD Mini Kiosk, Safe Water Kiosk or a semi permanent installation. Mobile Water Vendor (MVW) POD installations will most likely not require a filtrate storage tank and direct fill into containers. There are numerous arrangements and configurations for MWV users. SKYHYDRANT POD - USER GUIDE & DATA SHEET 6 SKYHYDRANT POD - USER GUIDE & DATA SHEET 6

7 MAXIMUM OPERATING WATER PRESSURE HEADER TANK water level MAXIMUM PRESSURE HEAD APPROXIMATELY 10 METRES MAXIMUM DIFFERENTIAL WATER PRESSURE APPROXIMATELY FILTRATE TANK 3 METRES water level WATER INLET TO DRINKING WATER TAPS SKYHYDRANT POD SKYHYDRANT ULTRAFILTRATION UNIT 2) Water Level Control Devices Water level control device allows water tanks to be maintained full of water, preventing tank overflow and saving water wastage. Various water level controllers include float valves float switches or a simple overflow system. Float Valve Example of a float valve: Example of a Disc filter 4) Post-Filtration And Treatment Devices 3) Pre-Filter Devices SkyHydrants will not remove chemicals or minerals from water, which simply pass through the system. Should these types of contaminates need to be removed, post treatment devices are available. Various types of post-filtration treatments include carbon (GAC) filters, water softeners, ultraviolet treatment, RO systems and chlorinators It is always suggested to consider Pre-filters to remove excessive contaminants from raw supply water with very high turbidity loadings It is sensible to consider a low maintenance robust design by reduce contaminant loading on the SkyHydrant and other equipment. A pre-filter would be installed prior to a SkyHydrant or prior to other equipment. Various types of pre-filters are available including cartridge and pleated filters, screen filters, disc filters and media filters..example of a carbon (GAC) filter: SKYHYDRANT POD - USER GUIDE & DATA SHEET 7

8 4 COMMENCE USING THE SKYHYDRANT POD Before start up, water pipes and equipment should be flushed with a chlorine solution to eliminate contamination. See Section 7 Water Quality Maintenance" for amount of chlorine to use. 1. Fill the Unit with Water Open T1 Dirty Water In and T4 Vent. Wait until water flushes out T4 and Close T4 Vent. 2. Produce Drinking Water Open T3 Clean Water Out to commence the flow of drinking water. from raw water supply Vent WALL MOUNT BRACKET HANDLE Use to shake clean Ball valve to drinking taps to drainage SKYHYDRANT POD - USER GUIDE & DATA SHEET 8

9 5 CLEANING THE SKYHYDRANT POD To prevent the POD from becoming clogged, regular cleaning is essential. The cleaning process is easy and involves two processes as outlined below: Shake & Flush: undertaken daily; and Solution Cleaning: undertaken monthly. SHAKE & FLUSH CLEANING (Undertake Daily Or More Often If Needed) Shake the POD back and forth using the handle on the side of the unit. Next, flush out the dirty contaminates while continue shaking. Undertake this at least once a day or more often as necessary to maintain the correct flow of drinking water. M1 M2 Close all valves. At this time the POD should be full of water. Shake the POD back and forth using the Cleaning Handle on the side of the unit for about 30 seconds. This movement cleans the filter module inside the unit. Wall bracket M3 Flush the POD by opening T4 VENT and T2 BACKWASH OUT and continue Shaking the POD until water flowing from T2 BACKWASH OUT. After this close T2. HANDLE Move handle back and forth to shake the POD which cleans the filter module inside Note: to be sure the POD has been correctly cleaned, the colour of water flowing from T2 during backwash should be the same colour as water flowing into T1. If this is not apparent then refill the POD and repeat the shake and flush process. M4 The Manual Cleaning Procedure is now complete. Open T4 VENT until water flows out and close T4. Open T3 CLEAN WATER OUT to resume flow of drinking water. SHAKE BACK AND FORTH Open T1 Backwash Out and T4 Vent to flush the POD while continuing the shaking movement SKYHYDRANT POD - USER GUIDE & DATA SHEET 9

10 SOLUTION CLEANING (Undertake monthly or as often as needed) Solution cleaning removes accumulated organic matter and other contaminants not removed by the regular manual cleaning. Follow the process below: SOLUTION CLEANING USING CHLORINE Undertake monthly (or as necessary) Chlorine is used to remove deposits of organic matter form inside the filtration unit. Prepare a chlorine solution in a jug of water (about 500ml) and stir until dissolved. See table below for amount of chlorine to add. This should create a 0.2% chlorine solution inside the filter housing. The chlorine manufacturer will state the chlorine concentration on the label, this will determine how much chlorine to add using the information below: CHLORINE Chlorine powder with 65% available chlorine (700g/kg of chlorine) Chlorine powder with 55% available chlorine (550g/kg of chlorine) Chlorine powder with 35% available chlorine (350g/kg of chlorine) Chlorine powder with 25% available chlorine (250g/kg of chlorine) Liquid chlorine (Sodium Hypochlorite) with 12% available chlorine SKYHYDRANT:POD 1 teaspoon 2 teaspoon 3 teaspoon 4 teaspoon 70ml Follow steps C1 to C5 below: C1 C2 C3 C4 C5 Undertake Steps M1 to M3 of the SHAKE & FLUSH (listed on previous page). Close T1 DIRTY WATER IN and open T4 VENT. Note: the POD at this time should be empty of water. Open tap T5 SOLUTION and use a funnel to add the solution mixture, close tap T5-SOLUTION. Open taps T1 DIRTY WATER IN and allow the unit to fill with water and immediately close T4 VENT when water spills out. Close T1 DIRTY WATER IN and leave to soak for 4 hours or longer. After soaking carry out SHAKE & FLUSH, follow Steps M1 to M4. On completion the unit is ready to be returned back to producing drinking water again. SOLUTION CLEANING USING CITRIC ACID Undertake every 6 months Citric acid is used to remove inorganic materials such as iron and manganese deposits from inside the filtration unit. Prepare a Citric Acid solution in a jug of water (about 500ml) and stir until dissolved. CITRIC ACID SOLUTION Fine Granular Citric Acid SKYHYDRANT:POD 180 gms STEP 1 STEP 2 STEP 3 Complete a SOLUTION CLEAN USING CHLORINE (as above) and flush the unit with water when complete. Undertake steps C2 and C3 (as above) but use Citric Acid powder instead of chlorine in STEP 2. Complete steps C4 to C5 (as above), however in step C4 leave the citric acid to soak for 12 hours (not 4 hours). This procedure is now complete. IMPORTANT: Safe Use of Chemicals: Follow manufacturer s safety instructions. Avoid contact with skin and wear protective gloves, eyeglasses and clothing. Do not inhale fumes. SKYHYDRANT POD - USER GUIDE & DATA SHEET 10

11 6 FEED WATER SUITABILITY Not all water is suitable for filtering through SkyHydrant ultrafiltration units (UF) and testing for unsuitable contaminants should be undertaken before use. YES Effective removal of diseases Biological contaminants and pathogens including bacteria, viruses, protozoa, cysts, parasites significantly removed. (LRV4+ removal) YES Turbidity Removed Turbidity and dirt significantly removed from water. NO Chemicals NOT Removed Salt or dissolved chemicals and minerals are not removed from water. ULTRAFILTRATION INFORMATION This patented low-pressure ultrafiltration technology has been proven and validated for drinking water applications. It is used extensively in municipal drinking water applications Low-pressure ultrafiltration membrane technology is highly effective in removing all non-dissolved species in feed waters. Ultrafiltration is classified by the World Health Organisation (WHO)* as effective removal of disease causing pathogens and exceeds requirements for key criteria to produce safe drinking water. However, it is important to test the water and validate the composition of the feed water. Please refer to the Technical Bulletins and Specifications to obtain specific information on Performance. Ultrafiltration (to 0.04um nominal) WILL REMOVE pathogens (disease causing organisms) and turbidity (dirt): 1. PATHOGENS removed (to log reduction value >4) by ultrafiltration include: Bacteria Protozoa Cysts Helminths Total Coliform TC Total Coliform FC Ecoli Virus (significantly reduces virus levels) 2. TURBIDITY (NTU = Nephelometric Turbidity Units) is removed by ultra-filtration to levels below <0.1 NTU. Turbid water contains suspended matter such as clay, slit, fine fragments of organic matter, and similar material. TURBIDITY levels of up to 1000 NTU can be removed however levels below 500 NTU are preferred. 3. TOTAL SUSPENDED SOLIDS (TSS) will be removed. TSS is similar to turbidity. 4. IRON AND MANGANESE if first oxidised or if colloidal can be removed by ultrafiltration. 5. ARSENIC MANGANESE if first oxidised can be removed by ultra iltration. * The World Health Organisation (WHO) reports that ultrafiltration provides complete removal of bacteria and and viruses (disease causing pathogens) as outlined in WHO document GUIDELINES FOR DRINKG WATER QUALITY under Treatment Process as referenced in the WHO website. SKYHYDRANT POD - USER GUIDE & DATA SHEET 11

12 Ultrafiltration (to 0.04um nominal) WILL NOT REMOVE chemicals or minerals or salinity (salt) from water: Note: mg/l (milligrams per litre) also equals ppm (parts per million); WHO (World Health Organisation) 1. Chemicals not removed by ultrafiltration include: Arsenic Cadmium Chromium Copper Cyanide Fluoride Lead Mercury Nickel Nitrate Nitrite Sulphate (unless first oxidised) (WHO safe drinking standard - Max 0.01 mg/l) (WHO safe drinking standard - Max mg/l) (WHO safe drinking standard - Max 0.05 mg/l) (WHO safe drinking standard - Max 2.0 mg/l) (WHO safe drinking standard - Max 0.07 mg/l) (WHO safe drinking standard mg/l) (WHO safe drinking standard - Max 0.01 mg/l) (WHO safe drinking standard - Max mg/l) (WHO safe drinking standard - Max 0.07 mg/l) (WHO safe drinking standard - Max 50 ml/l as NO3) (WHO safe drinking standard - 3 mg/l as NO2) (Safe Drinking Levels: 250 mg/l but up to 500mg/L can be tolerated 2. Minerals (hardness) is not removed by ultrafiltration, and includes: Total Hardness, hard water is mainly calcium and magnesium and is not considered a health risk but can be unpleasant to taste and cause a build up of scale in pipes (WHO safe drinking standard-max 500 mg/l) Calcium, Carbonate (WHO safe drinking standard- Max 250 mg/l) Iron and Manganese (unless first oxidised) (WHO safe drinking standard- 0.4 mg/l; Note: exceeding this level is not unsafe but is unpleasant to taste - max 1.0 mg/l) Magnesium (WHO safe drinking standard- Max 150 mg/l) 3. Salinity and salts are not removed by ultrafiltration include: Salinity (WHO safe drinking standard - Max 250 mg/l) Chloride and Sodium (WHO safe drinking standard - Max 600 mg/l) Conductivity (WHO safe drinking standard - Max 2000 us/cm) 4. Total dissolved solids (TDS) cannot be successfully removed by ultrafiltration: TDS (WHO safe drinking standard - Max 1000 mg/l) TDS contain a wide range of substances including organic and inorganic (chemicals) 5. Unpleasant tastes are not successfully removed in most cases using ultrafiltration. Ultrafiltration will have NO direct effect on ph levels: ph Scale (WHO safe drinking standard ) Total Alkalinity (WHO safe drinking standard max 500) ph levels are not considered a health issue but may cause corrosion or encrustation of plumbing fittings and pipes. SKYHYDRANT POD - USER GUIDE & DATA SHEET 12

13 7 WATER QUALITY MAINTENANCE To maintain filtered water in good condition it is recommended to undertake further treatment as well as regular maintenance. This will prevent post contamination. KEEP WATER PIPES AND CONTAINERS CLEAN Use a chlorine solution to sanitise and eliminate any residual post contamination, which may spread Disease in water pipes, drinking containers, hoses, taps, and other equipment. Use a 0.1% (1,000 ppm) chlorine solution (add approximately 1 teaspoon of chlorine powder to 5 litres of water) and flush Through pipes or wash drinking water containers. It is also recommended to regularly flush a chlorinated solution through the SkyHydrant together With drinking water hoses and pipes to eliminate any post contamination. PREVENT POST CONTAMINATION OF DRINKING WATER TANKS To maintain water quality it is good practice to regularly disinfect drinking water tanks and water pipes by adding a small amount of chlorine to prevent the growth of unwanted organisms and pathogens in The stored water. To achieve this, as a guide add about 3/4 teaspoon of chlorine powder (at 65% available chlorine) or 1½ teaspoons of chlorine powder (at 35% available chlorine) for every 1,000-litres of tank water. First, mix the chlorine in a small bucket of water to make a solution before adding the chlorine solution to the tank. It is recommended to use a water testing kit to maintain a free residual chlorine level of between 0.2 to 0.5 milligrams per litre (mg/l) which is equivalent to 2 to 5 parts per million (ppm). Water should be tested regularly to maintain the chlorine levels and make adjustments as necessary. 8 LONG TERM STORAGE OF THE SKYHYDRANT POD When the SkyHydrant POD is placed into storage for future use, it is essential that the filter fibres must remain wet and moist at all time to prevent permanent damage. It is stored in a very mild chlorine Solution. This controls growth of bacteria, as well eliminating fibres from drying out. When placing the ultrafiltration unit into storage: Undertake a chemical clean and leave at least 1 litre of clean water inside the unit (or preferably leave the unit full of clean water with 5 to 10ppm chlorine) to maintain a wet environment. Turn all valves off before placing the unit into storage. Do not store in conditions below freezing. After storage undertake a chemical clean to restore the filter module back to normal operation condition. SKYHYDRANT POD - USER GUIDE & DATA SHEET 13

14 9 PERFORMANCE MONITORING At start up it is recommended the flow rate of the SkyHydrant:POD be measured and recorded. This will determine if the flow rate decreases in the future. To undertake this procedure, allow water to flow into T1 (dirty water in) from a measured height (say 2 metres) and use a stopwatch to time how long it takes to fill a measured bucket of water (say 10 litres) out of T3 (clean water out). On a regular basis repeat this procedure. If the flow rate decreases it may indicate more frequent cleaning of the ultrafiltration unit be undertaken. Over the lifetime of the ultrafiltration unit there will be a natural loss of flow due to ageing of the filter fibres. OPERATION LOG SHEETS It is good practice to keep a daily operational log-sheet (see Log Sheet on the last page) to record drinking water production flow rates and when cleaning procedures were undertaken. TIME DATE DRINKING MANUAL WATER CLEANING PRODUCTION UNDERTAKEN CHEMICAL CLEANING UNDERTAKEN AMOUNT CHLORINE USED OTHER INFORMATION OR NOTES SKYHYDRANT POD - USER GUIDE & DATA SHEET 14

15 10 TECHNICAL DATA - SKYHYDRANT Typical Application Filtration of potable non-saline surface water or groundwater for communities. Not suitable for use with seawater or brackish water or other water sources containing contaminants such as heavy metals. Model S-POD Nominal 5,000 litres per day Typical Feed Inlet Pressure Range for Gravity Feed Maximum Housing Operating Pressure Membrane Module Details Materials of Construction: Module Housing Assembly Valves Seals and Gaskets Pipe and Fittings Filter Mode Operation Feed Pre-Screen Mesh Size Recommended Max. Recommended Feed Turbidity Filtered Water Turbidity Typical Log Reduction Value Operating Feed Temperature Range Temperature Range for Tansportation and Storage Feed ph Range Allowable ph Range for Cleaning 1 metres to 4 metres head pressure 100kPa MEMCOR membrane filtration module polyvinylidene fluoride (PVDF) hollow fibre ultrafiltration membrane with nominal pore size 0.04µm. Food grade polyethylene (PE) Various including PVC and PP EPDM typical Various including PE, ABS, Nylon and PVC Pressurised outside to inside filtration 500µm or finer 50 NTU < 0.1 NTU > 4 LRV (for particles 2 to 5µm) > 0 to 35 C ( > 32 to 95oF) > 0 to 35 C ( > 32 to 95oF) Note: The unit must not be allowed to freeze 6.0 to 9.0 ph Note: not recommended in feeds below 6.5 ph 2 to 10 ph typical Waste Water Volume Per Backwash Backwash Typical Target Chlorine Concentration During a Chlorine Clean Typical Target Acid Concentration During an Acid Clean Weight and Dimensions Recommended Installation Location Approximately 2.5 litres Gravity drain waste outlet with Mechanical Agitation and or shake 300 to 500mg/L / 300 to 500ppm 2.0 to 2.2pH (not less than 2.0pH) using Citric Acid Powder H: 77 cm x D: 20 cm x W: 28 cm <> Dry weight :10 Kgs Installed under cover with protection from direct sunlight and rainfall 1 Feed water quality will affect production capacity. 2 Unscreened or coarsely screened raw water may reduce membrane operating life. 3 Capacity and backwashing/cleaning frequency will typically vary with feed turbidity. SKYHYDRANT POD - USER GUIDE & DATA SHEET 15

16 Patented Product of Australia Tel SkyHydrant is a registered trademark of SkyJuice Foundation Inc. REGISTERED INTERNATIONAL PATENT The information provided in this literature contains indicative general descriptions and characteristics of performance. The actual performance may vary so this information is only indicative. SkyJuice may change and or alter this product as a result of further development. SkyJuice makes no warranty or claims on suitability of feedwater and complete compliance to WHO standards. Users make must make their own independent enquiries and be satisfied with feedwater suitability. This obligation is NOT passed to SkyJuice. An obligation to provide the respective characteristics shall only exist if specifically and expressly agreed in the terms of the contract. Please refer to SkyJuice terms and conditions of sale for obligations and warranty

SkyHydrant-MAX. SkyHydrant-GEM. Nominal 6,000 litres per day Height - 82 cm Depth - 18 cm Width - 25 cm Mass (dry) - 9 kg Mass (wet) - 21 kg

SkyHydrant-MAX. SkyHydrant-GEM. Nominal 6,000 litres per day Height - 82 cm Depth - 18 cm Width - 25 cm Mass (dry) - 9 kg Mass (wet) - 21 kg TABLE OF CONTENTS Operating Instructions... 01 How the SkyHydrant Works... 04 How to Maintain Water Quality... 06 Ultrafiltration Removal Criteria... 08 Data Sheet... 11 Operating Log... 15 SkyHydrant-MAX

More information

PRO. Safe, clean drinking water on tap anywhere, anytime with UF-PRO Ultrafiltration Units...

PRO. Safe, clean drinking water on tap anywhere, anytime with UF-PRO Ultrafiltration Units... UF PRO ULTRAFILTRATION UNIT Safe, clean drinking water on tap anywhere, anytime with UF-PRO Ultrafiltration Units... LONG TERM, HIGH PERFORMANCE FILTERS SIMPLIFIED CLEANING PROCESS Low cost, safe potable

More information

AQUAVENDOR AUTO. Ultrafiltration Unit SETUP OPERATING INSTRUCTIONS

AQUAVENDOR AUTO. Ultrafiltration Unit SETUP OPERATING INSTRUCTIONS AQUAVENDOR AUTO OPERATING INSTRUCTIONS Ultrafiltration Unit SETUP Locate the Ultrafiltration Unit undercover with sufficient space around the unit for maintenance and for installing plumbing connections.

More information

ULTRAFILTRATION UNIT

ULTRAFILTRATION UNIT UNIT R SETUP OPTIONS SkyHydrant Ultrafiltration Units can be setup and configured to accommodate numerous site applications. Various setup options have been outlined in the following diagrams and discriptions

More information

DATA SHEET AUTOMATED MEMBRANE SOLUTION FOR SMALL SCALE WATER TREATMENT

DATA SHEET AUTOMATED MEMBRANE SOLUTION FOR SMALL SCALE WATER TREATMENT ULTRAFILTRATION UNIT DATA SHEET AUTOMATED MEMBRANE SOLUTION FOR SMALL SCALE WATER TREATMENT 1 DATA SHEET The - Series of ultrafiltration units provide stand alone capability requiring no additional operating

More information

Skyhydrant. Membrane filtration. Project in cooperation with Norplan And Ministry of Rural Rehabilitation Department

Skyhydrant. Membrane filtration. Project in cooperation with Norplan And Ministry of Rural Rehabilitation Department Skyhydrant Membrane filtration Project in cooperation with Norplan And Ministry of Rural Rehabilitation Department May 2015 Written by Cecilie Kolstad Summary Fetching water from rivers, springs and ponds

More information

Water supplied by Marafiq does not meet the process requirements.

Water supplied by Marafiq does not meet the process requirements. WATER TREATMENT In Industries Water is used for: a. Drinking b. Cleaning c. Cooling d. Producing Steam e. Process requirement Why we need to treat water? For human consumption a. Water to be purified (Make

More information

AQpure. water treatment systems COMMUNITY WATER SUPPLY MODULAR AND AUTOMATED ULTRAFILTRATION WATER TREATMENT FOR SUSTAINABLE DRINKING WATER

AQpure. water treatment systems COMMUNITY WATER SUPPLY MODULAR AND AUTOMATED ULTRAFILTRATION WATER TREATMENT FOR SUSTAINABLE DRINKING WATER GRUNDFOS LIFELINK AQpure COMMUNITY WATER SUPPLY AQpure water treatment systems MODULAR AND AUTOMATED ULTRAFILTRATION WATER TREATMENT FOR SUSTAINABLE DRINKING WATER ONSITE WATER TREATMENT FOR COMMUNITY

More information

PedalPure The Portable Ultra-Filtration Water Treatment System

PedalPure The Portable Ultra-Filtration Water Treatment System In many disasters, contaminated water remains a critical issue. The portable ultrafiltration PedalPure system would allow more victims access to clean and safe water for consumption and survival. The pedal-powered

More information

CHAPTER 2 COLD WATER SUPPLY. Prof. Dr. Uğur Atikol

CHAPTER 2 COLD WATER SUPPLY. Prof. Dr. Uğur Atikol CHAPTER 2 COLD WATER SUPPLY Prof. Dr. Uğur Atikol Water Supply Water Authorities mains Private Sources (Streams, Rivers, Lakes, Wells, Springs) The water used must be colourless, free from suspended matter

More information

MEMCOR MEMBRANES FOR DRINKING WATER APPLICATIONS

MEMCOR MEMBRANES FOR DRINKING WATER APPLICATIONS MEMCOR MEMBRANES FOR DRINKING WATER APPLICATIONS WHY CHOOSE MEMBRANE FILTRATION? As ever-tightening water regulations continue to challenge the limits of conventional filtration methods, municipalities

More information

RO400 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM RO400. Type of product. Date of purchase. Address

RO400 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM RO400. Type of product. Date of purchase. Address Type of product RO400 Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM 19 RO400 USER'S MANUAL 01 Introduction of RO400 02 What is Reverse Osmosis 03 Components& Selections 04 Cartridge filters

More information

U-Version. Incoming City Water

U-Version. Incoming City Water Ultra-Flo U-Version Ultra-Flo is a hollow-fibre based membrane filtration product. This filtration process covers the ultrafiltration range of between 0.1 to 0.01 micron. It is designed to remove suspended

More information

DOW Ultrafiltration. Case History. DOW Ultrafiltration Membranes Offer Reliable, Economical Answer to High Solids

DOW Ultrafiltration. Case History. DOW Ultrafiltration Membranes Offer Reliable, Economical Answer to High Solids Case History Membranes Offer Reliable, Economical Answer to High Solids Site Information Location: NingBo, China Capacity: 549 m 3 /h (2417 gpm) Purpose: Pretreat feed water to RO system Time in Operation:

More information

RO102 P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address RO102

RO102 P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address RO102 Type of product RO102 Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM PURE- REVERSE OSMOSIS SYSTEM 15 RO102 USER'S MANUAL 01 Introduction of RO102 02 What is reverse osmosis 03 Components

More information

KTDA SEMINAR WATER TREATMENT PRESENTATION. John Waema

KTDA SEMINAR WATER TREATMENT PRESENTATION. John Waema KTDA SEMINAR WATER TREATMENT PRESENTATION John Waema INTRODUCTION Filtration Systems Packaged Plants Ultrafiltration Plants Dosing Systems Reverse Osmosis Plants Mobile Water Treatment Plants Global water

More information

Advanced water purifier system operation manual and setup guide

Advanced water purifier system operation manual and setup guide Advanced water purifier system operation manual and setup guide What is Reverse Osmosis? Reverse osmosis, also known as hyper filtration, is the finest filtration known. This process will allow the removal

More information

FS-8000 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product FS Date of purchase. Address

FS-8000 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product FS Date of purchase. Address Type of product FS-8000 Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM 15 FS-8000 USER'S MANUAL 01 Introduction of FS-8000 02 What is Reverse Osmosis 03 Components& Selections 04 Cartridge

More information

RV AND TOWING EQUIPMENT

RV AND TOWING EQUIPMENT I N D U S T R I E S RV AND TOWING EQUIPMENT Remco. Committed to delivering professional grade pump solutions. The Remco line of products represents our enduring commitment to deliver exceptional products

More information

OPERATING & MAINTENANCE MANUAL

OPERATING & MAINTENANCE MANUAL ULTRAFILTRATION UNIT OPERATING & MAINTENANCE MANUAL AUTOMATED MEMBRANE SOLUTION FOR SMALL SCALE WATER TREATMENT UF ULTRAFILTRATION UNIT Contents Introduction Setting Up the UF- Quick Operating Guide Operating

More information

Demineralisation. PUROTAP expert. Installation Function Operation Service. Demineralised heating water.

Demineralisation. PUROTAP expert. Installation Function Operation Service. Demineralised heating water. EN Demineralised heating water Demineralisation PUROTAP expert Installation Function Operation Service Demineralised heating water makes heating systems safe in accordance with VDI 205 and SWKI BT 102-01

More information

REVERSE OSMOSIS SYSTEM USER'S MANUAL. Excellent Product, Excellent Water! My PurePro X6

REVERSE OSMOSIS SYSTEM USER'S MANUAL. Excellent Product, Excellent Water! My PurePro X6 REVERSE OSMOSIS SYSTEM USER'S MANUAL UV Plus! Excellent Product, Excellent Water! My PurePro X6 PUREPRO X6 Thank you very much for selecting Pure-Pro Water Corp. In order to bring the best use of your

More information

Valve Nest Filter with Time Clock Control Installation and Operation Manual

Valve Nest Filter with Time Clock Control Installation and Operation Manual Valve Nest Filter with Time Clock Control Installation and Operation Manual Effective 5/24/12 Effective 5/24/12 Table of Contents Operating Data. 1 Pre-Installation Data... 2 Filter Parameters Installation

More information

PRODUCTS & APPLICATIONS COURSE WATER TREATMENT PRESENTATION John Waema

PRODUCTS & APPLICATIONS COURSE WATER TREATMENT PRESENTATION John Waema PRODUCTS & APPLICATIONS COURSE WATER TREATMENT PRESENTATION John Waema INTRODUCTION Filtration Systems Dosing Systems Packaged Plants Reverse Osmosis Systems Waste Water Treatment Plants Mobile Water Treatment

More information

Reverse Osmosis Desalinators

Reverse Osmosis Desalinators Reverse Osmosis Desalinators H2O Series Framed and Modular Technical Specification Cathelco Seafresh, Marine House,Dunston Rd, Chesterfield, Derbyshire, England, S41 8NY Tel: +44 (0)1246 45790 Fax: +44

More information

Introduction of HR-800(M) Components. Cartridge filters. Installation diagram. Change membrane. Change filters. Operation regulation FAQ

Introduction of HR-800(M) Components. Cartridge filters. Installation diagram. Change membrane. Change filters. Operation regulation FAQ Introduction of HR-800(M) Components Cartridge filters Installation diagram Change membrane Change filters Operation regulation FAQ Maintenance checking list Memo Thank you very much for selecting Hyundai

More information

Sawyer PointONE Filter

Sawyer PointONE Filter Sawyer PointONE Filter Using technology taken from kidney dialysis, Sawyer water filters use Hollow Fiber Membranes. Our filters are comprised of tiny U shaped micro tubes that allow water to enter into

More information

Drinking Water Supply and

Drinking Water Supply and Drinking Water Supply and Health Engineered Water Systems Water and Health 80% of sickness in the world is caused by inadequate water supply or sanitation 40% of the world population does not have access

More information

EMERGENCY WATER. Immediate delivery when emergency response for water and/or waste water is required

EMERGENCY WATER. Immediate delivery when emergency response for water and/or waste water is required EMERGENCY WATER Immediate delivery when emergency response for water and/or waste water is required Sigma have wide-spread capabilities in providing robust emergency water solutions. With extensive support

More information

WARNING: only use TEFLON tape to seal filter connections. Do not use other types of sealing material or the warranty shall be null and void.

WARNING: only use TEFLON tape to seal filter connections. Do not use other types of sealing material or the warranty shall be null and void. Dear Customer, Thank you for choosing this Filter. Carefully read the in-formation in this manual before installing the filter. Failure to observe the indicated instruction null and voids all warrantees.

More information

DOW Ultrafiltration. Case History. DOW Ultrafiltration Modules Protect Reverse Osmosis System from High Iron

DOW Ultrafiltration. Case History. DOW Ultrafiltration Modules Protect Reverse Osmosis System from High Iron Case History Modules Protect Reverse Osmosis System from High Iron Site Information Location: ShanXi, China Capacity: 2074 m 3 /h (5283 gpm) Purpose: Pretreat waste water prior to RO system Time in Operation:

More information

Village of McBride Annual Water System Report

Village of McBride Annual Water System Report Village of McBride Annual Water System Report - 2016 June 2017 The Village of McBride Annual Water System Report - 2016 McBride Water System Annual Report for 2016 In 2016 the McBride water system supplied

More information

Purite Water Purification Systems

Purite Water Purification Systems SELECT WATER PURIFICATION Water Purification The Select range of high performance water purification systems offers a unique combination of reliability, quality and functionality for all laboratory applications.

More information

AQpure. water treatment systems RAINWATER HARVESTING

AQpure. water treatment systems RAINWATER HARVESTING GRUNDFOS COMMERCIAL BUILDINGS AQpure RAINWATER HARVESTING AQpure water treatment systems MODULAR AND AUTOMATED ULTRAFILTRATION WATER TREATMENT FOR SUSTAINABLE WATER SERVICES IN COMMERCIAL BUILDINGS ONSITE

More information

ERS-106UV USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

ERS-106UV USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address Type of product Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM 15 ERS-106UV USER'S MANUAL 01 Introduction of ERS-106UV 02 What is reverse osmosis 03 Components & Selected filters 04 Cartridge

More information

Water for Dialysis Part 1: Components

Water for Dialysis Part 1: Components Water for Dialysis Part 1: Components Danilo B. Concepcion, CBNT, CHT-A, FNKF danilo.concepcion@stjoe.org (714)771-8944 The findings and conclusions in this presentation are those of the author and do

More information

AstroBoy Quick install guide

AstroBoy Quick install guide AstroBoy Quick install guide Water Inlet connection Water can be diverted to the AstroBoy by either using the tap diverter or the opella valve. Tap diverter From your main kitchen mixer tap unscrew the

More information

EC106M USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product EC106M. Date of purchase. Address

EC106M USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product EC106M. Date of purchase. Address Type of product EC106M Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM 15 EC106M USER'S MANUAL 01 Introduction of EC106M 02 What is reverse osmosis 03 Components & Selected filters 04 Cartridge

More information

Owners Manual 320-USP-DS-10, 320-USP-DS-20. US Water Systems Pulsar Disruptor Pre-Filter. Visit us online at

Owners Manual 320-USP-DS-10, 320-USP-DS-20. US Water Systems Pulsar Disruptor Pre-Filter. Visit us online at Visit us online at www.uswatersystems.com US Water Systems Pulsar Disruptor Pre-Filter Owners Manual 320-USP-DS-10, 320-USP-DS-20 REVISION # 1.1 REVISION DATE May 24, 2018 US Water Systems Corporate Office

More information

Farm Water Quality Considerations

Farm Water Quality Considerations Farm Water Quality Considerations The quality of water on farm can have economic impacts for farmers through its effects on livestock, crop production, and the effectiveness of pesticides and other agricultural

More information

D R I N K I N G W A T E R T R E A T M E N T S Y S T E M S

D R I N K I N G W A T E R T R E A T M E N T S Y S T E M S 1 Queen Anne s Gate London SW1H 9BT Tel +44(0)20-7957 4554 Fax +44(0)20-7957 4565 E-mail: info@britishwater.co.uk website: www.britishwater.co.uk Chief Executive David Neil-Gallacher, LVO Registered in

More information

Congratulations! Dear Customer,

Congratulations! Dear Customer, Congratulations! Dear Customer, You are now the proud owner of ZERO-B PISTINE, India s first Domestic Reverse Osmosis water treatment system, form the Consumer s Product Division of Ion Exchange (India)

More information

Ultrafiltration with pre-coagulation in drinking water production Literature review

Ultrafiltration with pre-coagulation in drinking water production Literature review April, 2007 Ultrafiltration with pre-coagulation in drinking water production Literature review Introduction Ultrafiltration is a pressure driven membrane process, which is increasingly applied in advanced

More information

Puroxi Pure Water Global Inc. Shield 500/1000 Drinking Water System (DWS)

Puroxi Pure Water Global Inc. Shield 500/1000 Drinking Water System (DWS) Puroxi Pure Water Global Inc. Shield 500/1000 Drinking Water System (DWS) Contents: 1. Shield vs. RO System Comparison 2. DWS Equipment Configuration 3. Incoming Water Specification 4. Incoming Water Test

More information

ULTRA PURE SYSTEMS 75,150,200 GPD RODI INSTALLATION AND OPERATION MANUAL

ULTRA PURE SYSTEMS 75,150,200 GPD RODI INSTALLATION AND OPERATION MANUAL ULTRA PURE SYSTEMS 75,150,200 GPD RODI INSTALLATION AND OPERATION MANUAL Thank you for choosing UPS (Ultra-Pure Systems) for your RO/DI solution. We are confident you have made the right decision. This

More information

Membrane Technique MF UF NF - RO

Membrane Technique MF UF NF - RO Membrane Technique MF UF NF - RO AquaCare GmbH & Co. KG Am Wiesenbusch 11 45966 Gladbeck, Germany +49-20 43-37 57 58-0 +49-20 43 37 57 58-90 www.aquacare.de e-mail: info@aquacare.de Membrane Technique

More information

Treatment of all source water influent & effluent for user application, be it commercial, industrial, domestic, to defined & required standards.

Treatment of all source water influent & effluent for user application, be it commercial, industrial, domestic, to defined & required standards. Overview of services for Influent & Effluent Treatment Solutions offered by Nimbus technologies Generally and as a rule, source water from a local water supplier is treated and should meet with SANS 241

More information

Recent Advances in Membrane Technologies Peter D Adamo, Ph.D., P.E Spring Conference Wilmington, NC April 13, 2015

Recent Advances in Membrane Technologies Peter D Adamo, Ph.D., P.E Spring Conference Wilmington, NC April 13, 2015 2015 Spring Conference Wilmington, NC April 13, 2015 Recent Advances in Membrane Technologies Peter D Adamo, Ph.D., P.E. 2014 HDR, Inc., all rights reserved. Membrane Filtration Basics Recent Membrane

More information

ERS-106M USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

ERS-106M USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address Type of product Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM 15 ERS-106M USER'S MANUAL 01 Introduction of ERS-106M 02 What is reverse osmosis 03 Components & Selected filters 04 Cartridge

More information

SGLP-RO. Installation and Operating Instructions for SCALEGARD TM LP REVERSE OSMOSIS FILTRATION SYSTEM. 3M TM Water Filtration Products

SGLP-RO. Installation and Operating Instructions for SCALEGARD TM LP REVERSE OSMOSIS FILTRATION SYSTEM. 3M TM Water Filtration Products 3M TM Water Filtration Products Installation and Operating Instructions for SCALEGARD TM LP REVERSE OSMOSIS FILTRATION SYSTEM SGLP-RO Installer: Please leave this manual with owner/operator. LIMITED WARRANTY

More information

Absolute purity. No Compromise on features

Absolute purity. No Compromise on features Absolute purity. No Compromise on features USER MANUAL Contents 01) Welcome to Livpure Family 02 02) Know your Livpure Water Purifier 03 03) Water Flow Diagram 04 04) How your Livpure Water Purifier works

More information

Boss Water Systems Australia Reverse Osmosis System Model 021-4P-GM

Boss Water Systems Australia Reverse Osmosis System Model 021-4P-GM Boss Water Systems Australia Reverse Osmosis System Model 021-4P-GM Congratulations on your purchase of the most advanced water purifier system available! Installation and Service Guide short web version,

More information

S800-Direct Flow USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

S800-Direct Flow USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address Memo Type of product S800-Direct Flow Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM 15 S800-Direct Flow USER'S MANUAL 01 Introduction of S800-Direct Flow 02 What is reverse osmosis 03 Components

More information

USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM ET-PURE. Type of product. Date of purchase. Address

USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM ET-PURE. Type of product. Date of purchase. Address Type of product ET-PURE Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM 15 ET-PURE ET-PURE USER'S MANUAL 01 Introduction of ET-PURE 02 What is reverse osmosis 03 ET-PURE layout and components

More information

Commercial Reverse Osmosis System

Commercial Reverse Osmosis System Commercial Reverse Osmosis System Aqua Clear Water Treatment Specialists manufacturers and engineers standard and custom commercial reverse osmosis systems water to accomodate many different water conditions.

More information

OPERATION AND MAINTENANCE MANUAL UF-6-HF ULTRAFILTRATION SYSTEM

OPERATION AND MAINTENANCE MANUAL UF-6-HF ULTRAFILTRATION SYSTEM OPERATION AND MAINTENANCE MANUAL UF-6-HF ULTRAFILTRATION SYSTEM Con-Serv Manufacturing 805 West Brannen Road Lakeland, FL 33813 (800) 868 9888 www.con-servwater.com Introduction This manual includes the

More information

Cartwright Consulting Co.

Cartwright Consulting Co. Cartwright Consulting Co. WWW.CARTWRIGHT-CONSULTING.COM pscartwright@msn.com United States Office European Office 8324 16 th Avenue South President Kennedylaan 94 Minneapolis, MN 55425-1742 2343 GT Oegstgeest

More information

DIRECT ACCESS Easy maintenance. CLICK Secure connections. NSF CONNECTORS High quality and trusted. ZERO INSTALLATION Ready to use.

DIRECT ACCESS Easy maintenance. CLICK Secure connections. NSF CONNECTORS High quality and trusted. ZERO INSTALLATION Ready to use. DIRECT ACCESS Easy maintenance. CLICK Secure connections. ENCAPSULATED MEMBRANE Maximum hygiene, minimum contact. ELECTRONIC ADAPTOR High yield stability. NSF CONNECTORS High quality and trusted. FT QUICK

More information

CERTIFICATE OF ANALYSIS

CERTIFICATE OF ANALYSIS 1 CERTIFICATE OF ANALYSIS ATTENTION: Water Purification Solutions DATE: 29 November 2018 1. GENERAL: Table-1: Tierkloof Borehole & Product - Sampled 1 November 2018 Results expressed in parts per million

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL Pure Water Group P.O. Box 785 Calistoga, CA 94515 pure-water-group.com Toll Free: 310.993.9929 Pure Water Group 2015 puropod is Made in the USA Distributed by Pure Water

More information

Cartwright Consulting Co.

Cartwright Consulting Co. Cartwright Consulting Co. WWW.CARTWRIGHT-CONSULTING.COM pscartwright@msn.com United States Office European Office 8324 16 th Avenue South President Kennedylaan 94 Minneapolis, MN 55425-1742 2343 GT Oegstgeest

More information

RS-106M-P USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

RS-106M-P USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address Type of product Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM 15 RS-106M-P USER'S MANUAL 01 Introduction of RS-106M-P 02 What is reverse osmosis 03 Components & Selected filters 04 Cartridge

More information

RO105TDS P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo PRO REVERSE OSMOSIS SYSTEM. Type of product RO105TDS. Date of purchase.

RO105TDS P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo PRO REVERSE OSMOSIS SYSTEM. Type of product RO105TDS. Date of purchase. Power Good Bad Type of product RO105TDS Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM PURE- REVERSE OSMOSIS SYSTEM 15 RO105TDS USER'S MANUAL 01 Introduction of RO105TDS 02 What is reverse

More information

SC-Series Commercial Scale Elimination Systems

SC-Series Commercial Scale Elimination Systems SC-Series Commercial Scale Elimination Systems Featuring Watts OneFlow Technology No Scale No Waste Minimal Pressure Loss Total Satisfaction Water Control Corporation is pleased to bring you the very latest

More information

Make Water Anywhere with Pall Integrated Membrane Systems

Make Water Anywhere with Pall Integrated Membrane Systems Make Water Anywhere with Pall Integrated Membrane Systems Tim Lilley, Pall Corporation Portsmouth, April 2012 COPYRIGHT 2012 The information contained in this document is the property of the Pall Corporation,

More information

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal Technical Bulletin 2004-02 rev0707 Q: What is the AdEdge AD26 System? A: The AD26 system is a pre-engineered, packaged treatment system specifically

More information

OLTRE CAP V- SERIES OUTSIDE IN AIR SCOUR ULTRAFILTRATION MEMBRANES

OLTRE CAP V- SERIES OUTSIDE IN AIR SCOUR ULTRAFILTRATION MEMBRANES OLTRE CAP V- SERIES OUTSIDE IN AIR SCOUR ULTRAFILTRATION MEMBRANES CONTENTS 1. Company profile 1 2. Description of OLTRE CAP -V ultrafiltration module 2 2.1 Features of OLTRE CAP -V series outside-in UF

More information

MAVEA Professional. Basics on water

MAVEA Professional. Basics on water MAVEA Professional Basics on water Introduction Water is the most sought after ingredient in everyday life. Water is the key requisite of sustaining all life on earth. As humans we know the water we have

More information

CRG CONSERVE RESOURCES GROUP ECO ENVIRONMENTAL ENGINEERING TECHNOLOGIES. CRG Water Division Humanitarian Department

CRG CONSERVE RESOURCES GROUP ECO ENVIRONMENTAL ENGINEERING TECHNOLOGIES. CRG Water Division Humanitarian Department Water Division Humanitarian Department BLCG Water Resources Ltd BLCG Humanitarian Ltd Peace Times Installations of WTM Modules VILLAGE APPLICATION Rural Areas or Villages outside the City Using Model :

More information

Crab and Lobster Live Holding Systems Part III - (Filters and Instrumentation)

Crab and Lobster Live Holding Systems Part III - (Filters and Instrumentation) Crab and Lobster Live Holding Systems Part III - (Filters and Instrumentation) 1990/3/SF/AM The rapid development of the British Shellfish Industry and the requirement to export live shellfish has lead

More information

USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address EC Introduction of EC What is reverse osmosis

USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address EC Introduction of EC What is reverse osmosis Memo Type of product Date of purchase EC105 Name Address Tel REVERSE OSMOSIS SYSTEM USER'S MANUAL 01 Introduction of EC105 02 What is reverse osmosis 03 Components & Selected filters 04 Cartridge filters

More information

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System.  January 2012 Version MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SCP Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description

More information

Water Quality Parameters

Water Quality Parameters Water Quality Parameters Kenya WASH Cluster Training for Emergencies Oct 2008 4.08 - Water in emergencies Physical Colour, ph, odour, taste, temperature, turbidity etc. Chemical Metals, pesticides, salinity,

More information

Aqualife Products (Australia) Pty Ltd Steam Sterilisor Water System

Aqualife Products (Australia) Pty Ltd Steam Sterilisor Water System Aqualife Products (Australia) Pty Ltd Steam Sterilisor Water System AquaClave P5 REVERSE OSMOSIS WATER TREATMENT SYSTEM Attention USER S MANUAL 01 Introduction of AquaClave 02 What is reverse osmosis 03

More information

Water Treatment Technology

Water Treatment Technology Lecture 4: Membrane Processes Technology in water treatment (Part I) Water Treatment Technology Water Resources Engineering Civil Engineering ENGC 6305 Dr. Fahid Rabah PhD. PE. 1 Membrane Processes Technology

More information

Some Standard Membranes: Filmtec Membrane, Hydronatics Membrane, Torry membrane and Koch Membrane.

Some Standard Membranes: Filmtec Membrane, Hydronatics Membrane, Torry membrane and Koch Membrane. REVERSE OSMOSIS (RO) water treatment process involves water being forced under pressure ( Osmatic Pressure ) through a semipermeable membrane. Temporary and permanent hardness, Total Dissolved Soilds (TDS),

More information

Ultrafiltration Technical Manual

Ultrafiltration Technical Manual Ultrafiltration Technical Manual Copyright by: inge AG Flurstraße 17 86926 Greifenberg (Germany) Tel.: +49 (0) 8192 / 997 700 Fax: +49 (0) 8192 / 997 999 E-Mail: info@inge.ag Internet: www.inge.ag Contents

More information

Biosecurity. Best Practice in the Breeder House

Biosecurity. Best Practice in the Breeder House Biosecurity Best Practice in the Breeder House Best Practice in the Breeder House Biosecurity Introduction 1 Biosecurity creates hygienic conditions within the poultry house to minimize the adverse effects

More information

REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION

REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION SERVICE DEIONIZATION (SDI) Service Deionization (SDI) from Evoqua is a safe and economical way for you to obtain consistent, high-purity water

More information

Touch Series. India s most advanced RO water purifier with touch technology USER MANUAL

Touch Series. India s most advanced RO water purifier with touch technology USER MANUAL Touch Series India s most advanced RO water purifier with touch technology USER MANUAL Contents 01) Welcome to Livpure Family 02 02) Know your Livpure Water Purifier 03 03) Water Flow Diagrams 04-05 04)

More information

Table of Contents BEFORE INSTALLATION INSTALLATION OPERATION MAINTENANCE TECHNICAL & WARRANTY INFORMATION

Table of Contents BEFORE INSTALLATION INSTALLATION OPERATION MAINTENANCE TECHNICAL & WARRANTY INFORMATION Table of Contents BEFORE INSTALLATION Overview...1 Using Quick-Connect Fittings...2 System Maintenance...2 Installation Notes...2 Operational Parameters...3 Contents of the Reverse Osmosis (RO) System...3

More information

PRODUCTS CATALOGUE. Solar powered desalination and water purification

PRODUCTS CATALOGUE. Solar powered desalination and water purification PRODUCTS 2018 - CATALOGUE Solar powered desalination and water purification 1 World s leading products in water purification powered by renewable energy Solar Water Solutions is a Finnish water technology

More information

Welcome to the Pureit family World s largest selling purifier INSTRUCTION MANUAL. Classic - S X B 6 1 Classic - S Y B 6 1

Welcome to the Pureit family World s largest selling purifier INSTRUCTION MANUAL. Classic - S X B 6 1 Classic - S Y B 6 1 Welcome to the Pureit family World s largest selling purifier INSTRUCTION MANUAL Classic - S X B 6 1 Classic - S Y B 6 1 KNOW YOUR PUREIT MINERAL RO+MF / RO+UV* 220 V TANK FULL 1 CHANGE SF/GKK 4 2 6 7

More information

Membrane Systems. Featuring Aqua MultiBore Membranes

Membrane Systems. Featuring Aqua MultiBore Membranes Membrane Systems Featuring Aqua MultiBore Membranes Aqua-Aerobic Membrane Systems Featuring Aqua MultiBore Membranes For nearly 50 years, Aqua-Aerobic Systems has provided thousands of customers with adaptive

More information

CeraMem. Ceramic Membrane Technology. Advanced Heavy Metals Removal System WATER TECHNOLOGIES

CeraMem. Ceramic Membrane Technology. Advanced Heavy Metals Removal System WATER TECHNOLOGIES CeraMem Ceramic Membrane Technology Advanced Heavy Metals Removal System WATER TECHNOLOGIES Key System Features CeraMem UF membranes act as an absolute barrier to oils, suspended solids, and precipitated

More information

EC106M-P USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product EC106M-P. Date of purchase. Address

EC106M-P USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product EC106M-P. Date of purchase. Address Type of product EC106M-P Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM 15 EC106M-P USER'S MANUAL 01 Introduction of EC106M-P 02 What is reverse osmosis 03 Components & Selected filters

More information

RECYCLED WATER AT SYDNEY OLYMPIC PARK. Andrzej Listowski SYDNEY OLYMPIC PARK AUTHORITY

RECYCLED WATER AT SYDNEY OLYMPIC PARK. Andrzej Listowski SYDNEY OLYMPIC PARK AUTHORITY RECYCLED WATER AT SYDNEY OLYMPIC PARK Andrzej Listowski SYDNEY OLYMPIC PARK AUTHORITY INTEGRATED URBAN WATER CYCLE AT SYDNEY OLYMPIC PARK - CONTEXT INTRODUCTION TO SYDNEY OLYMPIC PARK INTEGRATED WATER

More information

Trident. Package Water Treatment System

Trident. Package Water Treatment System Trident Package Treatment System The Trident Package Treatment System When Microfloc products first introduced the Trident technology, it represented a significant advancement in water and wastewater treatment

More information

Producing High-Purity Recycled Water for Industrial Applications with Microfiltration and Reverse Osmosis: Lessons Learned

Producing High-Purity Recycled Water for Industrial Applications with Microfiltration and Reverse Osmosis: Lessons Learned Producing High-Purity Recycled Water for Industrial Applications with Microfiltration and Reverse Osmosis: Lessons Learned ABSTRACT Mallika Ramanathan*, Alicia Cohn*, John Hake*, Ken Abraham**, Srinivas

More information

SPECIFICATION NO.1197S Addendum No.4 Attachment D. Appendix L- Ground Water Quality Data and Revised Construction Groundwater Discharge Plan

SPECIFICATION NO.1197S Addendum No.4 Attachment D. Appendix L- Ground Water Quality Data and Revised Construction Groundwater Discharge Plan SPECIFICATION NO.1197S Addendum No.4 Attachment D Appendix L- Ground Water Quality Data and Revised Construction Groundwater Discharge Plan Page 1 of 2 Specification No. 1197S Addendum No. 4 ATTACHMENT

More information

Agenda. Pretreatment Background Typical Contaminants Practical Examples Methods of Treatment and References

Agenda. Pretreatment Background Typical Contaminants Practical Examples Methods of Treatment and References Pretreatment of Seawater for Desalination Plants Richard Dixon, ITT Agenda Pretreatment Background Typical Contaminants Practical Examples Methods of Treatment and References 2 Typical Constituents in

More information

Owners Manual 320-USP-LB-10, 320-USP-LB-20. US Water Systems Limeblaster Salt-Free Water Conditioner. Visit us online at

Owners Manual 320-USP-LB-10, 320-USP-LB-20. US Water Systems Limeblaster Salt-Free Water Conditioner. Visit us online at Visit us online at www.uswatersystems.com US Water Systems Limeblaster Salt-Free Water Conditioner Owners Manual 320-USP-LB-10, 320-USP-LB-20 REVISION # 1.3 REVISION DATE October 10, 2018 US Water Systems

More information

Water Quality. CE 370 Lecture 1. Global Distribution of Earth s s Water

Water Quality. CE 370 Lecture 1. Global Distribution of Earth s s Water Water Quality CE 370 Lecture 1 Global Distribution of Earth s s Water Water Demand and Supply in Saudi Arabia Total Water Consumption = 22 billion m 3 /Year Water Demand Water Supply Industrial Domestic

More information

Reclaimed Waste Water for Power Plant Cooling Tower Water & Boiler Feed Make-up. Richard Coniglio, Business Product Manager

Reclaimed Waste Water for Power Plant Cooling Tower Water & Boiler Feed Make-up. Richard Coniglio, Business Product Manager Reclaimed Waste Water for Power Plant Cooling Tower Water & Boiler Feed Make-up Richard Coniglio, Business Product Manager 70% Covered with Water 3% is Fresh Water 1% of the Fresh Water is only accessible.

More information

Water Quality Report for ALDERNEY NORTH Monitoring Water Quality. Water Quality Parameters and their Standards

Water Quality Report for ALDERNEY NORTH Monitoring Water Quality. Water Quality Parameters and their Standards Water Quality Report for ALDERNEY NORTH Monitoring Water Quality The Government requires all water companies to comply with the Water Supply (Water Quality) Regulations. These regulations are based upon

More information

Water treatment system and water quality Standard, Configuration and Practical Considerations

Water treatment system and water quality Standard, Configuration and Practical Considerations Water treatment system and water quality Standard, Configuration and Practical Considerations Mr. TSE Lok-him Electronics Engineer Electrical and Mechanical Services Department 1 1 What is Water Treatment

More information

HEALTHY TONGA TOURISM A GUIDE TO SAFE RAINWATER HARVESTING FOR TOURIST ACCOMMODATION BUSINESSES IN TONGA

HEALTHY TONGA TOURISM A GUIDE TO SAFE RAINWATER HARVESTING FOR TOURIST ACCOMMODATION BUSINESSES IN TONGA HEALTHY TONGA TOURISM A GUIDE TO SAFE RAINWATER HARVESTING FOR TOURIST ACCOMMODATION BUSINESSES IN TONGA Contents 1. Purpose of guide 1 2. Safe drinking-water 1 3. Rainwater harvesting 2 4. Safe rainwater

More information

Use of Spiral Wound UF in RO Pretreatment

Use of Spiral Wound UF in RO Pretreatment Use of Spiral Wound UF in RO Pretreatment Authors: Harry Dalaly, Asia Pacific Sales Manager, Hydranautics and Yeoh Cheik How, Facilities Senior Engineer, Hewlett-Packard Singapore The Hewlett-Packard Singapore

More information

Pathogens in Water. Monitoring, Control and Technologies Available for Treatment. Prepared by; Paul O Callaghan M.Sc. Dr.

Pathogens in Water. Monitoring, Control and Technologies Available for Treatment. Prepared by; Paul O Callaghan M.Sc. Dr. Pathogens in Water National Water Summit, Tuesday, 2nd October 2007 Monitoring, Control and Technologies Available for Treatment Prepared by; Paul O Callaghan M.Sc. Dr. Hans Gethke Filtration of drinking

More information

City of Redding Water Utility 2006 Consumer Confidence Report

City of Redding Water Utility 2006 Consumer Confidence Report City of Redding Water Utility 26 Consumer Confidence Report Water Supply Sources Our water sources include surface water from the Sacramento River and Whiskeytown Lake and groundwater from the Redding

More information