PROBUILD GUIDE SUBCONTRACTOR QUALITY MANAGEMENT. Section Two Project Specific Quality Management Plans. Version No 1.
|
|
- Jesse Derek Neal
- 6 years ago
- Views:
Transcription
1 PROBUILD SUBCONTRACTOR QUALITY MANAGEMENT GUIDE Section Two Project Specific Quality Management Plans Version No 1.
2 PREFACE This document has been developed to assist subcontractors to meet Probuild s Quality Management (QM) requirements whilst working on a Probuild project. The document should be able to be used as guidance to assist your organisation to meet a number of the key requirements of your contractual agreement with Probuild when working on a Probuild project. Note: This document is for guidance purposes only. Probuild does not accept any liability for the use of this document, or any losses incurred as a result of using this document.
3 INDEX 1.0 Introduction Definitions Project Specific Quality Management Plans Project organisation Scope of works Contract Documents Samples Shop drawings Inspection and Test Plans Calibration Certificates Non-conformance Procedure Purchasing Procedure Defects Management Document Control...6 Attachment One Project Specific Quality Management Plan Template...6 Attachment Two Development of the Subcontractor Inspection and Test Plans and Template. 9
4 1.0 INTRODUCTION Probuild is committed to continual improvement in our effectiveness in relation to the delivery of our Client s projects. Our subcontractors are fundamental to this delivery. Probuild has developed this Subcontractor Quality Management Guide with the intent of providing our subcontractors with guidance regarding our expectations in relation to quality management and to support these with standard templates. Subcontractors on Probuild projects are required, as specified in the Subcontract Agreement Terms & Conditions (Clause 23.0), to have a documented quality management system in place that is compliant with ISO 9001, and to submit a project specific Quality Management Plan for the works to be undertaken. This guide has been prepared to enhance subcontractors existing quality management and or, in the absence of a system, provide basic templates to ensure compliance with Probuild s quality management requirements. We have also taken the liberty, in preparing this guide, to take the opportunity to highlight to our subcontractors the benefits to their organisation of developing, implementing and maintaining a Quality Management System. These benefits may include managing risk, reducing costs, increasing profit and obtaining repeat business. This document is divided into two distinct sections. The first section provides information regarding the benefits of quality management and a description of quality management systems, namely ISO The second section provides guidance on developing a project specific quality management plan and information on developing Inspection and Test Plans. The relevant attachments contained within this document are to be completed and provided to the Site Quality Facilitator or Contract Administrator at least 72 hours prior to commencement on site. 2.0 DEFINITIONS Head contractor refers to Probuild Client refers to Probuild s client Subcontractor refers to the organisation contracted to Probuild to undertake a specific scope of work Quality Management (QM) is the performance of tasks, which ensures that construction is performed according to plans and specifications, on time, within a defined budget, and in a safe work environment. Quality Management System (QMS) is a management system to direct and control an organisation with regard to quality. It provides a structure, including documentation and processes, which enables the delivery of products and services to be controlled and managed to consistently meet the specific requirements. Quality Management Plan (QMP) is a project specific plan developed by the subcontractor to plan and carry out the contract works for a specific project, to ensure conformity with the requirements for the project contract and to manage any risks. Inspection and Test Plan (ITP) is a single document that records all inspection and testing requirements relevant to a specific process, it includes hold and witness points, references relevant Australian Standards, other relevant standards and acceptance criteria and records to be maintained. It should reflect the requirements of the contract documents, that is the drawings and specifications. Hold point defines a point beyond which work may not proceed without the authorisation of a designated subcontractor personnel, (i.e. foreman) and may include the Head Contractor, Client or consultant or authority (local council, WorkSafe etc). Witness point provides the nominated party (such as the Head Contractor, Client, consultant, regulatory authority) with the opportunity to witness the inspection or test or aspect of the work, at their discretion. Surveillance intermittent monitoring of any stage of the work in progress whether by the subcontractor, head contractor or client. Self inspection where the subcontractor performing the work verifies the quality progressively, often with the aid of checklists.
5 3.0 PROJECT SPECIFIC QUALITY MANAGEMENT PLANS A Quality Management Plan (QMP) is a project specific plan developed by the subcontractor to plan and carry out the contract works for a specific project, to ensure conformity with the requirements of the project contractual requirements and to manage any risks. The QMP should be used and updated throughout the course of the project. Probuild requires its subcontractors to develop a project specific Quality Management Plan on being awarded a contract and prior to their commencement on site, and will provide advice and guidance, should it be required, in relation to the development of a plan. A template to assist subcontractors with developing a project specific Quality Management Plan is provided in Attachment 1. A Quality Management Plan should, as a minimum, clearly define the following: 3.1 Project organisation Identify the personnel within your organisation specifically assigned with the responsibility for ensuring quality management, on this project and the respective levels of authority. 3.2 Scope of works A preliminary assessment of your scope of works will assist you with identifying key areas of risk prior to task commencement. Describe the extent of the following: Project definition Extent of contract works and programme Works you will contract out 3.3 Contract Documents Document the relevant drawings, specification reference, Australian Standards, inspections and tests required and any other process controls or quality procedures necessary. Refer Item 5.6 for further information regarding inspection and test plans. 3.4 Samples Ensure, if applicable, samples required to be submitted for approval are as prescribed in the specification and submitted in a timely manner, allowing for the approval process and subsequent lead times so as not to delay the construction programme. Samples should be submitted in accordance with the project sample approval process. 3.5 Shop drawings Ensure, if applicable, shop drawings required to be submitted for approval are as prescribed in the specification and submitted in a timely manner, allowing for the approval process and subsequent lead times so as not to delay the construction programme. Shop drawings should be submitted in accordance with the project shop drawing approval process. 3.6 Inspection and Test Plans Inspection and Test Plans (ITPs) are required to document the procedure to be undertaken for a given construction activity and the necessary evidence required to demonstrate that a particular work process / product or activity conforms to the specified requirements (i.e. drawings and relevant sections of the specification for verification of ITPs). The content of ITPs is based on the contract drawings, specifications, Australian Standards and any legislative or regulatory requirements. An ITP would: Refer: Detail the activity, area and job steps Detail the inspections and tests required, including hold and witness points, possibly recorded on checklist. Identify acceptance criteria, sampling and testing methods and frequency of sampling / testing Identify responsibilities for inspection and testing and product/service approval Detail the records to be provided, including those required for identification and traceability. Attachment 2 Development of the Subcontractor Inspection and Test Plans and Template Attachment 3 - Inspection and Test Plans samples
6 3.7 Calibration Certificates Nominate all equipment to be used that provides a test result and requires calibration. Ensure all eligible equipment is calibrated in accordance with appropriate standards and the results are available. 3.8 Non-conformance Procedure The subcontractor should have in place a process for reporting and the management of non-conformances. The key objective of reporting non-conformances is to provide an opportunity to identify the root causes of non-conformances and to enable the implementation of controls to prevent the re-occurrence of non-conformances. This will provide the subcontractor, and Probuild, with the opportunity to improve work practices, improve the performance of its systems, and to enhance cost savings and other quality related issues. Where the subcontractor does not have a procedure Probuild s Non-Conformance Procedure may be applied. 3.9 Purchasing Procedure A purchasing procedure, in addition to assisting with controlling costs, should ensure the subcontractor is able to meet the quality standards specified through good communication and planning with its suppliers. A purchasing procedure should allow for verification of conformance to the contract requirements (i.e. the product supplied is the product specified and records are maintained to demonstrate that). It may include the process for controlling customer supplied product (e.g. where the client provides the tiles for the tiler to lay), and how the subcontractor will manage non-conforming products Defects Management Effective quality management should reduce or eliminate defects. A defects management procedure may include commencing a defects register at the beginning of the project, scheduling weekly walk-throughs of the work site, and promptly rectifying defects as they arise Document Control A process should be in place to ensure that operatives / supervisors on site are using current contract documents (drawings, specifications). Common poor quality related causes on construction sites: Not building to drawings or specifications Using superseded drawings or specifications Inability to use ITP s effectively Use of inexperienced or unskilled workers Poor supervision leading to bad workmanship Insufficient management of the quality of construction Not learning from prior mistakes 4.0 ATTACHMENTS Attachment 1 - Project Specific Quality Management Plan Template Attachment 2 Development of the Subcontractor Inspection and Test Plans and Template Attachment 3 - Inspection and Test Plans samples
7 TRADE CONTRACTOR / SUBCONTRACTOR QUALITY MANAGEMENT PLAN Attachment 1 CONTRACTOR NAME: PROJECT: ANTICIPATED COMMENCEMENT DATE ON SITE: Plan to be forwarded to Probuild Management prior to commencement on site. PERSONNEL The following personnel will be responsible for Quality Management duties on the project: Name Title Phone number QM on site Others responsible for QM in the org SCOPE OF WORK: CONTRACT DOCUMENTS - Drawings: Specification Reference: Australian Standards: Inspections and tests: Other:
8 SAMPLES* (IF APPLICABLE) The following samples are to submitted for approval: Sample / Area Sample submission date Sample approval required by *Note: refer to Probuild s sample approval process for the project SHOP DRAWINGS* (IF APPLICABLE) The following shop drawings are to submitted for approval: Area / Item Submission date Approval required by ITP s *Note: refer to Probuild s shop drawing approval process for the project
9 Key works for which Inspection and Test Plans will be undertaken on the project: ITP title Proposed frequency of submission (eg. one ITP per zone, room, day or product) Tests and Inspections required and supporting evidence to be provided (eg. Test results, dockets, reports, engineering certificates, survey, photographs) EQUIPMENT CALIBRATION Equipment to be used on site requiring calibrated: Copies of current certificates / reports submitted to Probuild: PROCEDURES / PROCESSES Subcontractors procedure / process provided: Comments: Non-conformance Procedure Purchasing Procedure Defects Management Document Control PLAN PREPARED BY: Name Title Phone number
10 Attachment 2 COMPONENTS OF AN INSPECTION AND TEST PLAN Roles and responsibilities The subcontractor is responsible for ensuring all required ITP s within its scope of work (including for works it subcontractors out) are developed and should appoint someone who is skilled and experienced with the works in question to do so. A senior representative of the subcontractor should approve the ITPs and any amendments prior to its submission to Probuild. Inspection and Test Plans It is not desirable or practical to inspect and test 100% of works undertaken, therefore it is necessary to give consideration to the frequency and sampling process of testing to suit the works involved. ITPs are often best done after a number of separate activities, but prior to a major one that will cover up previous work. Preliminary testing will assist in providing an early indication of conformity. The type and extent of inspections and tests are often specified within the contract documents (e.g. drawings and specifications), however the subcontractor should also apply his/her knowledge and experience to the type, timing and frequency of inspections and tests to suit the risks and work involved. What to test, how to test and when to test is governed by: What the work is and how complex it is Consequences of failure, including: o Cost of remedial work o o o o o Effect on construction programme Accessibility for rectification (i.e. will the work be covered up) Disruption to use of building or structure Consequential damage to other elements Threat to safety of workers and public Records Records are essential because they provide the documented evidence necessary to verify that a product / service is in accordance with the contract requirements. The records may be in various forms, and may include checklists, test certificates, certificates of compliance, survey data, written approvals and the like. The ITP should define the records required. Acceptance Criteria Acceptance criteria is normally defined in the contract documents (either directly or by reference to other standards such as Australian Standards). Where this is not the case it is necessary to identify the acceptance criteria with the head contractor. Inspection / test procedures For many inspections / tests, the methods employed will be specified or self evident. In other cases, the precise manner in which the inspection / test is carried out would need to be identified and described. A typical test procedure using statistical techniques might, for example, cover: Reference to work areas / lots or batches Frequency of sampling Method of taking samples Method of conducting a test Qualifications of test personnel and equipment calibrations/condition/specification Hold and Witness Points Method of documenting results. It is the subcontractor s responsibility to identify the hold and witness points required for its employees and subcontractors doing the work. This is done so the subcontractor can be confident that the work is being carried out to the standards required. Probuild, and or its client, retains the option to inspect the work at any stage and may identify hold and witness points requiring their attendance. Checklists The logical stage to carry out an inspection or test is often after a number of separate activities, but prior to a major one that will cover up previous work. It is often useful to complete checklists at such stages and with each inspection and test where they will, in effect, summarise the procedures that have, and should have, taken place up to the particular point in the work process. Checklists remind the person doing the work of all matters that are to be addressed and confirm that all matters have been attended to. They also remind the person inspecting the work of all matters that should be checked.that checklists exist, and that their use and content have been verified, would give Probuild confidence that the person doing the work is aware of all important steps, attributes and matters to be addressed, and the standards that should be complied with, and the conformity is being verified.
11 DEVELOPMENT OF THE SUBCONTRACTOR INSPECTION AND TEST PLANS Preparing Inspection and Test Plans The following steps should be undertaken when preparing ITP s for a construction project: Step 1 Read the contract documents, including the specifications, and prepare a list of any discrepancies, ambiguities, missing information and standards of materials and/or workmanship that are considered inappropriate. Step 2 Contact Probuild and resolve the issues as identified in Step 1. Step 3 Examine the scope of work and divide it into separate areas requiring an ITP, based on a risk assessment basis. As a general guide it is normally most convenient to document a separate ITP for each trade or work area/section. Step 4 Note the Hold and Witness points required by the client. Step 5 Review the contract documents again and note the requirements that have the most impact on the quality of the finished product. For each ask the question what will be the consequences if it is not confirmed this is right? Be certain to include any references to tests, submitting information to the client, obtaining approvals and Hold and Witness Points. Step 6 Determine from Step 5 which items or aspects of each inspection will need to be recorded on checklists and prepare these. Step 7 Discuss the checklists with those directly involved with the work and obtain their input. This input should particularly be directed at identifying those issues that have caused problems (and involved extra costs) in the past, and therefore warrant checking at the earliest opportunity to avoid unnecessary and costly rectification. Step 8 Prepare each ITP to reflect the requirements of the contract documents. Reference the ITP in the Quality Management Plan and cross-reference to other related ITPs. Step 9 Issue each ITP and/or associated certification to Probuild for review within a reasonable period prior to commencing the work described in the Plan and adjust them to suit any comment received. Step 10 Decide how best to divide the whole work into work areas for control purposes and indicate these locations either on a schedule (with reference to grids and levels) or by marking up drawings. This may also be developed into an ITP programme. Step 11 Prepare and issue checklists for each work area and identify them according to location. Step 12 Train those directly involved with each of the ITPs in their use. If necessary formalise a procedure for the notification of Witness and Hold points. Step 13 Carry out inspections and tests in accordance with the ITP, provide notices to Probuild and/or regulatory authorities for Hold or Witness points, as designated or applicable, and record the results on checklist.
12 Subcontractor s name here,& Subcontract logo optional [Project Name] ITP No. : Inspection and Test Plan Prepared By: TRADE / TASK: Date: Location (Area/Unit/Grids): INSPECTION METHOD: V: Visual T: Test M: Measure ITEM VERIFICATION: S : Surveillance/Monitor H Hold Point (Mandatory) W : Witness Point (Optional) INSPECTION & TEST ITEMS (Include description, characteristics & necessary inspections and/or tests) Inspect. Method ACCEPTANCE CRITERIA Specification / Standard / Drawings ITEM VERIFICATION ACTION COMPLETE Subcontractor Builder Key Sign & Date Key Sign & Date NOTES / COMMENTS VERIFICATION Completed by Subcontractor at end of work This is to confirm (Name of subcontractor personnel responsible for work) has carried out all necessary inspections and verify that the work has been completed and conforms to the contract specification. Signature: Date: ATTACHMENTS Inspection Report Test Results / Certificates Checklists Product Details Calibration certificates Sample Material Dockets Other.. QMS-AUS-TM-402/2 QMS ISSUE DATE: xx xx 2011 P12/13
13 QMS ISSUE DATE: xx xx 2011 P13/13
Quality Manual DRAFT. Quality Management Plan Version A1 Date: <22/01/11> Page 1 of 17
Quality Manual DRAFT Page 1 of 17 Document Acceptance and Release Notice This is Revision A1 of the East Coast Designer Builders Quality Manual. The Manual is a managed document. For identification of
More informationTable of Contents. Project Agreement Schedule 14
Table of Contents PART 1 DEFINITIONS... 3 PART 2 INTEGRATED MANAGEMENT SYSTEM REQUIREMENTS... 6 2.1. Introduction... 6 2.2. Overview... 6 2.2.1 Management System Requirements... 7 2.2.2 Certification...
More informationPURCHASING AND RECEIVING INSPECTION
PURCHASING AND RECEIVING INSPECTION Rev Issued To Title Date Signed By Rev 0 Management Team 12-03-07 ###### Rev 1 Management Team 19-04-07 ###### Rev 2 Management Team 25-05-09 ###### Rev 3 Management
More informationSUPPLY AND INSTALLATION OF TURBINES AND GENERATORS CONTRACT SCHEDULE 8 QUALITY MANAGEMENT TABLE OF CONTENTS
SUPPLY AND INSTALLATION OF TURBINES AND GENERATORS CONTRACT SCHEDULE 8 QUALITY MANAGEMENT TABLE OF CONTENTS 1 INTERPRETATION... 1 1.1 Definitions... 1 2 QUALITY MANAGEMENT SYSTEM... 2 2.1 Quality Management
More informationPosition Description: Site Supervisor Reports to: Site Manager/Project Manager
Position Description: Site Supervisor Reports to: Site Manager/Project Manager Overall Responsibilities Direct onsite supervision of staff and subcontractors. Application of knowledge, skills, tools, and
More informationEnvironmental Roles and Responsibilities
Environmental Roles and Responsibilities All members of staff have a responsibility for their actions and the following impact on the companies identified environmental risks. All staff have responsibilities
More informationGuidance on the Application. of ISO / IEC Accreditation International Association for Certifying Bodies
Accreditation International Association for Certifying Bodies Guidance on the Application of ISO / IEC 17020 Guidance on the Application of ISO/IEC 17020 Page 1 of 16 Introduction This guidance document
More informationPosition Description: Site Manager Reports to: Project Manager
Position Description: Site Manager Reports to: Project Manager Overall Responsibilities To live the organisational values of Creating Opportunities, Building Communities and Empowering Lives. Responsible
More informationEnwon (Australia) Pty Ltd
PROJECT QUALITY MANAGEMENT PLAN Project: Client: QUALITY STATEMENT The Management of Enwon is committed to the delivery of works and services in compliance with quality requirements for all of the company
More informationINS QA Programme Requirements
Specification Date: 20/3/17 INS QA Programme Requirements UNCONTROLLED WHEN PRINTED Author: J Cooch AUTHORISATION Date: 20/3/17 A Brown Owner: J Cooch (Signature) N.B. only required for hard copy If issued
More informationCMI Guidance Document
CMI Guidance Document for Product Quality Plan Requirements Reference CMI-GD-PQP This document has been produced by the Administration Department of CertMark International (CMI). For technical information
More informationAssociation of American Railroads Quality Assurance System Evaluation (QASE) Checklist Rev. 1/12/2017
Company: Prepared By: Date: Changes from previous version highlighted in yellow. Paragraph Element Objective Evidence 2.1 Objective of Quality Assurance Program 2.2 Applicability and Scope 2.3 QA Program
More informationQUALITY MANAGEMENT SYSTEM QUALITY MANUAL ISO 9001:2008
QUALITY MANAGEMENT SYSTEM QUALITY MANUAL ISO 9001:2008 EXPRESS CONTRACTING SERVICES PTY LTD TRADING AS GOLDEN BROWN CLEANING SERVICES Unit 8/217 Mickleham Road Tullamarine VIC 3043 www.goldenbrown.com.au
More informationI. Development, Submittal, and Acceptance of a Quality Management System
I. Development, Submittal, and Acceptance of a Quality Management System 1. Scope Under the Contract, quality assurance and quality control management are the responsibility of the Contractor. The Contractor
More informationJ. McCann & Co (Nottm) Ltd McCann House 110 Nottingham Road Chilwell Nottingham NG9 6DQ. Quality Manual
McCann House 110 Nottingham Road Chilwell Nottingham NG9 6DQ Quality Manual Quality Manual Issue I Dated 8 th October 2012 Contents Page Section 1 - Introduction 2 Section 2 - Company Details 2 Section
More informationOWNER USER INTEGRITY MANAGEMENT SYSTEM WRITTEN DESCRIPTION CHECKLIST AB-512(b)
Company Name: Written Description of QMS Title and Rev. Status: Person who is responsible for preparing the owner s QMS written description: Name: Title: Telephone No.: ( ) Fax No.: ( ) Cell No.: ( ) E-Mail:
More informationManaging Contractors Policy (ratified by Full Governing Body 7 th July 2015)
Alcester Academy To be the best that we can be Managing Contractors Policy (ratified by Full Governing Body 7 th July 2015) ALCESTER ACADEMY MANAGING CONTRACTORS POLICY REVIEW PROCEDURES The Managing Contractors
More informationProject Management Rail Safety Worker Competence
Discipline: HR08-004 Contents Discipline: People, Culture and Development Category: Procedure Project Management Rail Safety Worker Competence HR08-004 Applicability ARTC Network Wide Interstate Network
More informationQuality Assurance Manual
Quality Assurance Manual Current Electrical is committed to leading the market in satisfying customer needs by providing versatile and innovative electrical and control solutions We take pride in the ability
More informationISO 9001: 2008 Engineering Design Construction Quality Management System Sample - Selected pages (not a complete plan)
ISO 9001: 2008 Engineering Design Construction Quality Management System Sample - Selected pages (not a complete plan) Part 1: Project-Specific Quality Plan Part 2: Company Quality Manual Part 3: Submittal
More informationQUALITY ASSURANCE AND QUALITY CONTROL MANUAL
1 QUALITY ASSURANCE AND QUALITY CONTROL 2 TABLE OF CONTENTS SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION 9 SECTION 10 QUALITY POLICY & AUTHORITY MANAGEMENT RESPONSIBILITY
More informationDerlin Construction Limited QUALITY POLICY MANUAL ISO 9001:2008
Derlin Construction Limited QUALITY POLICY MANUAL ISO 9001:2008 Copy Number Issued to CONTROLLED / UNCONTROLLED Uncontrolled manuals are current at time of issue but will not be updated. Document history.
More informationCORPORATE QUALITY MANUAL
Corporate Quality Manual Preface The following Corporate Quality Manual is written within the framework of the ISO 9001:2008 Quality System by the employees of CyberOptics. CyberOptics recognizes the importance
More informationMGD 001. Guidance Document for MCS 001. Version 1.0
MGD 001 Guidance Document for MCS 001 Version 1.0 This Microgeneration Installation Standard is the property of Department of Energy and Climate Change (DECC), 3 Whitehall Place, London,SW1A 2HH. DECC
More informationCORPORATE STANDARD ROUTINE MAJOR WORKS DEVELOPERS AND ACCREDITED SUPPLIERS VERSION: 1.0
CORPORATE STANDARD ROUTINE MAJOR WORKS DEVELOPERS AND ACCREDITED SUPPLIERS VERSION: 1.0 Contents 1. Introduction... 5 2. Purpose... 5 3. Scope... 5 3.1 Audience... 6 4. Definitions... 6 5. The delivery
More informationFacilities Planning and Construction (FP&C)
Appendix 8.4a Facilities Planning and Construction (FP&C) UAA FP&C Quality Assessment Checklist (A) Project: PM: Project ID: Updated:
More informationHUGHS LIMITADA- SHEQ HSE RESPONSIBILITIES
HSE RESPONSIBILITIES All levels of Management take an active interest in the development and implementation of the Health & Safety and Environmental Management System. Demonstrating Leadership in HSE Participation
More informationPROJECT QUALITY PLAN Royal Darwin Hospital Expansion
APPENDIX 7.2 PROJECT QUALITY PLAN Royal Darwin Hospital Expansion Document: PMP-3-04 Revision: 1 Date: June 2013 Page 1 of 25 Table of Contents 1.0 REVISION & DISTRIBUTION...5 1.1 Amendments... 5 2.0 PROJECT
More informationProject Procedures 1.0 PURPOSE 2.0 SCOPE 3.0 REFERENCES. No.: P /21/2012 PAGE 1 OF 13 BASIS OF OPERATION
Project Procedures BASIS OF OPERATION 09/21/2012 PAGE 1 OF 13 1.0 PURPOSE The purpose of this procedure is to establish the basis of operations that ensures that Project activities, including engineering,
More informationPressure Piping Construction Requirements QMS written description verification CHECKLIST AB-518b
QMS written description verification CHECKLIST AB-518b Company Name: Company Address: Title of the written description of the management system or manual(s): Person responsible for the overall management
More informationQuality Management in Construction Projects 6. Dr. Nabil El Sawalhi
Quality Management in Construction Projects 6 Dr. Nabil El Sawalhi 1 Integrated Quality Management A quality system is a framework for quality management. It embraces: The organizational structure, procedure,
More informationCORPORATE STANDARD ROUTINE MINOR WORKS DEVELOPERS AND ACCREDITED SUPPLIERS
CORPORATE STANDARD ROUTINE MINOR WORKS DEVELOPERS AND ACCREDITED SUPPLIERS VERSION: 1.0 2.0 Corporate Standard Routine Minor Works Developers and Accredited Suppliers Contents 1. Introduction... 4 2. Purpose...
More information4. General requirements 4.1 Impartiality and independence F Organisation s SANAS No/s. Date/s of evaluation
Generic Checklist for Accreditation of Measurements and Verification of Energy Savings Inspection Bodies to ISO/IEC 17020: 2012 incorporating TR 81: Technical Requirements for the application of SANS/ISO/IEC
More informationASI National Structural Steelwork Compliance Scheme. A Guide for Clients, Builders and Prime Contractors
ASI National Structural Steelwork Compliance Scheme A Guide for Clients, Builders and Prime Contractors Version 2, 2017 USE OF THIS GUIDE This document is intended to be used by bodies responsible for
More informationA handbook for the public sector Health and safety in construction procurement
A handbook for the public sector Health and safety in construction procurement Edition 2 June 2017 Contents Introduction 2 Phase 1: Planning 5 Phase 2: Design 7 Phase 3: Tender 9 Phase 4: Contract 10 Phase
More informationCONTENTS. Quality Policy Statement. Managing Invitations to Tender. Rev 9
QUALITY PLAN CONTENTS Section 1 Section 2 Section 3 Section 4 Section 5 Quality Policy Statement Quality System Managing Invitations to Tender Design and Drawings Contract Management Section 1 Quality
More informationQSS 0 Products and Services without Bespoke Contracts.
QSS 0 Products and Services without Bespoke Contracts. Use: Typically Sub 50k processes without a bespoke contract. Amendment History Version Date Status V3 June 2018 Updated for 2018 deployment Contents
More information<Full Name> Quality Manual. Conforms to ISO 9001:2015. Revision Date Record of Changes Approved By
Conforms to ISO 9001:2015 Revision history Revision Date Record of Changes Approved By 0.0 [Date of Issue] Initial Issue Control of hardcopy versions The digital version of this document is
More informationFIDIC Contracts. Training Course in English language. May, 25-26, Two days course on:
FIDIC Contracts Training Course in English language May, 25-26, 2018 Two days course on: FIDIC Module 4 - FIDIC Contracts Management and Administration FIDIC 99 EDITIONS ESSENTIALS FOR WORKING IN INTERNATIONAL
More informationCO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE
CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.018 Version 1 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group
More informationExternal Supplier Control Obligations
External Supplier Control Obligations Health and Safety Barclays recognises that we have clear Health and Safety (H&S) responsibilities towards everyone impacted by our business operations including,
More informationPre-Qualification Questionnaire
K&B Builders (South West) Limited Grosvenor Lodge Peacemarsh Gillingham Dorset SP8 4EU T : 07841091559 E : kbbuilders.office@gmail.com Pre-Qualification Questionnaire K&B Builders work in a wide range
More informationLevel 6 NVQ Diploma in Construction Site Management (Construction)
Level 6 NVQ Diploma in Construction Site Management (Construction) Qualification Specification ProQual 2017 Contents Page Introduction 3 Qualification profile 3 Qualification structure 4 Centre requirements
More informationVersion 2 November Code of Practice. Consignment Based Conformity Assessment (CBCA) Services
Code of Practice Consignment Based Conformity Assessment (CBCA) Services November 2012 PREFACE Many developed countries have strong National Standards and Technical Regulations supported internally with
More informationMANUAL QUALITY CONTROL & QUALITY ASSURANCE
MANUAL QUALITY CONTROL & QUALITY ASSURANCE METROTEC ENGINEERING LLC P.O. BOX: 26045, DUBAI U.A.E TEL : 043889771 FAX:043889772 E Mail: metrotecengg@yahoo.com info@metrotec.ae Web: www.metrotec.ae 2 TABLE
More informationSee revision section. Resources, Roles, Responsibility, Accountability, and Authority. Section in OHSAS 18001:2007
1. PURPOSE The purpose of this document is to identify occupational health and safety roles and responsibilities at each function and level within the City of Dallas in accordance with the requirements
More informationQUALITY ASSURANCE REQUIREMENTS
SPACE AT MUCKLENEUK CAMPUS PRETORIA QUALITY ASSURANCE REQUIREMENTS SPACE AT MUCKLENEUK CAMPUS, PRETORIA Page 1 1.1 QUALITY ASSURANCE REQUIREMENTS In undertaking the works (including all incidental services
More informationWORK HEALTH AND SAFETY AUDIT STANDARD
WORK HEALTH AND SAFETY AUDIT STANDARD FORESTRY INDUSTRY South Australia, Victoria and Tasmania Safety Standards 2017 2017 Content I. Introduction... 2 II. Audit Criteria and Indicators... 3 1 PLANNING...
More informationMicrogeneration Installation Standard: MCS 001. MCS Contractor certification scheme requirements Issue 2.5
Microgeneration Installation Standard: MCS 001 MCS Contractor certification scheme requirements Issue 2.5 This Microgeneration Installation Standard is the property of Department of Energy and Climate
More informationDocument 2007 Rev 0 December 2005 Page 1 of 8
Document 2007 Rev 0 December 2005 Page 1 of 8 1. Scope... 2 2. Definitions... 2 a. LabTest...2 b. Factory Location/ Manufacturer's Premises...2 c. Manufacturer...2 d. Subcontractor...2 e. f. Out-Worker...2
More informationWHS Manual Insert Business Name & Logo
WHS Manual Insert Business Name & Logo Version5 Work Health & Safety Manual INDEX OVERVIEW 4 1. WORK HEALTH AND SAFETY POLICY 5 2. PLANNING, REVIEW AND EVALUATION 9 3. HAZARD IDENTIFICATIO, ASSESSMENT
More informationPOLICY MANUAL FOR ISO 9001:2008. Document: PM-9001:2008 Date: April 7, Uncontrolled Copy
POLICY MANUAL FOR ISO 9001:2008 Document: PM-9001:2008 Date: April 7, 2015 REVIEWED BY: Tim Powers DATE: 4-7-2015 APPROVED BY: C._Bickford Uncontrolled Copy DATE: 4-7-2015 1.0 GENERAL ISS: 1 REV: E Page:
More informationSignals Staff Competency Assessment
Discipline: Engineering (Signalling) Category: Procedure Signals Staff Competency Assessment EST-20-02 Applicability ARTC Network Wide CRIA (NSW CRN) Primary Source ESI-08-01 Document Status Version Date
More informationAPS Cleaning Quality Management System Scope of Certification The provision of commercial and industrial cleaning services throughout Queensland.
Quality Management System Scope of Certification The provision of commercial and industrial cleaning services throughout Queensland. Table of Contents Contents 1. Introduction... 3 1.1. Process Approach...
More informationUNI EN ISO 22000:2005 STANDARD CHECK-LIST
RINA AUDIT CHECKLIST (Nr.... of...) Audit of the Food Safety Management System Company Production site: Audit type: Preaudit: Stage 1 Stage 2: Surveillance: Recertification: Other:. Report Nr. Date: Auditor:
More informationInspection & Test Plans (ITP s)
Inspection & Test Plans (ITP s) A Step by Step Guide to Producing an ITP Based on the generic template provided, the following guidance takes you through the process for establishing an ITP: Step 1 Scope:
More informationLevel 6 NVQ Diploma in Construction Site Management (Construction)
Level 6 NVQ Diploma in Construction Site Management (Construction) Qualification Specification ProQual 2014 Contents Page Introduction 3 The Qualifications and Credit Framework (QCF) 3 Qualification profile
More informationIIW Manufacturer Certification Scheme for the Management of Quality in Welding
IIW Manufacturer Certification Scheme for the Management of Quality in Welding ANBCC s Assessment of Manufacturers of Welded Products Copyright EWF 2008 IIW MCS IIW Manufacturer Certification Scheme for
More informationCONSTRUCTION MANAGER
The South African Council for the Project and Construction Management Professions CONSTRUCTION MANAGER IDENTIFICATION OF WORK AND SCOPE OF SERVICES FOR CONSTRUCTION MANAGERS REGISTERED IN TERMS OF THE
More informationMicrogeneration Installation Standard: MCS 001. MCS Contractor certification Scheme requirements Issue 3.0
Microgeneration Installation Standard: MCS 001 MCS Contractor certification Scheme requirements Issue 3.0 This Microgeneration Installation Standard is the property of Department of Energy and Climate
More informationDECISION TO ACCREDIT
DECISION TO ACCREDIT Determine the requirements of the regulator, legislation and customer s needs prior to deciding on the standard to implement. Process is based on the following: Top management s decision
More informationEngagement of Temporary Staff including Agency Workers
Engagement of Temporary Staff including Agency Workers Ratification Process Lead Author: Developed by: Senior OD & HR Business Partner, C&P CCG Senior OD & HR Business Partner, C&P CCG Approved on and
More informationQuality management systems
L E C T U R E 9 Quality management systems LECTURE 9 - OVERVIEW Quality management system based on ISO 9000 WHAT IS QMS (QUALITY MANAGEMENT SYSTEM) Goal: Meet customer needs Quality management system includes
More informationInspection & Test Plans (ITPs)
Inspection & Test Plans (ITPs) EXECUTIVE SUMMARY The Inspection and Test Plan (ITP) is a quality assurance tool commonly used throughout the construction industry. An effective ITP may also aid communications,
More informationBRC Storage and Distribution Quality and Safety Management System Implementation Workbook
We have written this workbook to assist in the implementation of your BRC quality & safety management system. The workbook is divided into 8 steps that are designed to assist you in implementing your quality
More informationQUALITY MANUAL 1.0 INTRODUCTION POLICY AND OBJECTIVES DEFINITIONS SCOPE QUALITY SYSTEM... 3
CONTENTS QUALITY MANUAL 1.0 INTRODUCTION... 2 2.0 POLICY AND OBJECTIVES... 2 3.0 DEFINITIONS... 2 4.0 SCOPE... 3 5.0 QUALITY SYSTEM... 3 6.0 ORGANISATIONAL CHARTS... 4 6.0 BRISBANE HEAD OFFICE... 4 6.1
More informationHealth and Safety Management Standards
Management Standards Curtin University Sept 2011 PAGE LEFT INTENTIONALLY BLANK Management Standards Page 2 of 15 CONTENTS 1. Introduction... 4 1.1 Hierarchy of Documents... 4 2. Management System Model...
More informationQuality Assurance Manual Sample Company
Document last amended on 4/4/2018 Quality Assurance Manual Sample Company This document was prepared for Sample Client, on behalf of Sample Company TABLE OF CONTENTS - SAMPLE Quality Manual Series Introduction...
More informationSAI Global Full Service Team
General information regarding elements of the certification process is described below. A degree of flexibility and options in the certification process are available so please feel free to contact us
More informationQUALITY ASSURANCE MANUAL
Chettisham Business Park Chettisham, Ely, Cambs Cb6 1RY Tel. 01353 666399 Managing Director: Mr G. R. Hartwig QUALITY ASSURANCE MANUAL NOTE: This is a CONTROLLED Document. 1 ST Jan 2004 1.0 INTRODUCTION
More informationCHAPTER 10 FACILITIES EVALUATIONS (PRE-AWARD) SURVEYS PART 1 INTRODUCTION
CHAPTER 10 FACILITIES EVALUATIONS (PRE-AWARD) SURVEYS PART 1 INTRODUCTION 10-1 PURPOSE. This section prescribes procedures for conducting an evaluation of the facilities and capabilities of an offeror,
More informationUse of Manufacturers Laboratories For Surveillance Testing
HAR Agreement PERMANENT DOCUMENT PD 14 Use of Manufacturers Laboratories For Surveillance Testing Approved by the HAR Group on 24 April 2006 Date of issue: May 2006 This document contains 9 pages Including
More informationQUALITY MANUAL 1.0 INTRODUCTION POLICY AND OBJECTIVES DEFINITIONS SCOPE QUALITY SYSTEM... 3
CONTENTS QUALITY MANUAL 1.0 INTRODUCTION... 2 2.0 POLICY AND OBJECTIVES... 2 3.0 DEFINITIONS... 3 4.0 SCOPE... 3 5.0 QUALITY SYSTEM... 3 6.0 ORGANISATIONAL CHARTS... 4 6.0 BRISBANE HEAD OFFICE... 4 7.0
More informationWOODS CONTRACTING QUALITY ASSURANCE QUALITY CONTROL QA/QC MANUAL VERSION: REV.2
WOODS CONTRACTING QUALITY ASSURANCE QUALITY CONTROL QA/QC MANUAL VERSION: 2.011218 REV.2 CONTENTS SECTION 1: QUALITY POLICY & AUTHORITY SECTION 2: MANAGEMENT RESPONSIBILITY SECTION 3: QUALITY SYSTEMS SECTION
More informationWorkplace Safety and Health Guidelines Contractor Management
Published in September 2011 by the Workplace Safety and Health Council in collaboration with the Ministry of Manpower. All rights reserved. This publication may not be reproduced or transmitted in any
More informationAnnual Surveillance Audit Report
Annual Surveillance Audit Report Organisation Name Jet-Set (EU) Ltd t/as Meadow Court Organisation Address Trenchard Park Gardens, Minehead Road, Norton Fitzwarren, Taunton, Somerset TA2 6NS Audit location(s),
More informationProcedure 11 Recruitment and Training
Procedure 11 Recruitment and Training Table of Contents 1 Introduction... 2 2 Head Office Personnel... 2 3 Auditors and Technical Expert Recruitment... 4 3.1 Flowchart of Recruitment Process... 4 3.2 Auditors
More informationMaterials and Qualification Procedures for Ships
Materials and Qualification Procedures for Ships Approval of a Works for the Manufacture of Non-heat treated ERW Steel Pipes Revision 2, Sept 2014 Lloyd s Register Group Limited, its subsidiaries and affiliates
More informationRUWACON QUALITY MANUAL
RUWACON QUALITY MANUAL Rev Date Preparation Review Approved Description of Revision 1 29 June SHEQ Manager SHEQ Manager Managing 2011 Director Ruwacon (PTY) Ltd P.O. Box 13596 Noordstad 9303 THIS DOCUMENT
More informationAccreditation Criteria for In-service Inspection of Lifting Equipment
1 INTRODUCTION 1.1 This document has been produced by the Pakistan National Accreditation Council (PNAC) in conjunction with the PNAC Sectoral Committee for Inspection Bodies. It provides guidance to those
More informationNATIONAL HEAVY VEHICLE ACCREDITATION SCHEME BASIC FATIGUE MANAGEMENT AUDIT MATRIX
NATIONAL HEAVY VEHICLE ACCREDITATION SCHEME BASIC FATIGUE MANAGEMENT AUDIT MATRIX Operator name Location of audit Auditor name Audit Date: / / PURPOSE For the purposes of accreditation, the Basic Fatigue
More informationMaterials and Qualification Procedures for Ships
Materials and Qualification Procedures for Ships Approval of a Works for the Manufacture of Steel Forgings for Semi- Built and Continuous Grain Flow Crankshafts Revision 3, January 2015 Page 1 of 14 Lloyd
More informationThe National Heavy Vehicle Accreditation Scheme (NHVAS)
The National Heavy Vehicle Accreditation Scheme (NHVAS) Fatigue Management Guide April 2009 0 of 32 NHVAS Maintenance Management Guide April 2009 The National Heavy Vehicle Accreditation Scheme (NHVAS)
More informationAccreditation Criteria for In-service Inspection of Lifting Equipment
Accreditation Criteria for In-service Inspection G-24/02 Issue Date: 08/07/08 1 INTRODUCTION 1.1 This document has been produced by the Pakistan National Accreditation Council (PNAC) in conjunction with
More informationVendor Qualification Survey
1200 West 96 th St Minneapolis, MN 55431 Ph: 952-888-7900 Fax: 952-888-2719 Vendor Qualification Survey Vendor Information Company Name: Date: Address: City: Phone Number: email address: Product or Service
More informationHAUC England Advice Note No. 2014/02. Code of Practice for Inspections: Defects Not Causing Danger Inspections ENGLAND
HAUC England Advice Note No. 2014/02 Code of Practice for Inspections: Defects Not Causing Danger Inspections ENGLAND Version: VI Control Document No.: 1 Document Owner: Roger Culpin and Mark Ostheimer
More information(3) Major Service: Service(s) provided by a contractor that cost more than $250K per year and are considered high risk.
Health and Safety - Contractor Management Procedure - Outsourcing Major Services Section 1 - Summary (1) This Procedure details the process for engaging contractors that provide major services to Victoria
More informationQUALITY MANUAL ECO# REVISION DATE MGR QA A 2/25/2008 R.Clement J.Haislip B 6/17/2008 T.Finneran J.Haislip
UHV SPUTTERING INC Page 1 of 18 ECO REVISION HISTORY ECO# REVISION DATE MGR QA 1001 A 2/25/2008 R.Clement J.Haislip 1017 B 6/17/2008 T.Finneran J.Haislip 1071 C 1/13/2011 R.Clement J.Haislip 1078 D 5/15/2013
More informationRSPH Level 4 Certificate in Asbestos Laboratory and Project Management
RSPH Level 4 Certificate in Asbestos Laboratory and Project Management August 2016 Guided Learning Hours 18 Total Qualification Time 140 Ofqual Qualification Number 603/0275/6 Description Laboratory managers
More informationChapter 2 Parties to the Contract
Chapter 2 Parties to the Contract 2.1 Introduction Construction work may include building of a new structure, additions, alterations, expansion, replacement, dismantling, erection, commissioning, rehabilitation,
More informationUPGRADE ASSESSMENT CHECKLIST
Checklist Instructions : Prior to auditing each element, the auditor shall review the documentation and mark a 0 in each box where functions /departments are referenced. As each function/department is
More informationSENIOR PROJECT MANAGER
POSITION Reports To; Direct Reports; Key Relationships; SENIOR PROJECT MANAGER Regional Construction Manager Site Managers, other staff allocated to assigned projects Project Directors, Clients, Consultants,
More informationCorrelation Matrix & Change Summary
The correlation matrix compares the new requirements of ISO 9001:2015 to the requirements of ISO 9001:2008, and provides a summary of the changes. Correlation Matrix & Change Summary Introduction Correlation
More informationQuality Manual. Specification No.: Q Revision 07 Page 1 of 14
Page 1 of 14 Quality Manual This Quality Manual provides the overall quality strategy and objectives of Pyramid Semiconductor s quality system. It is based on the requirements of ISO 9000. This manual
More information(Insert Firm Name) Quality System Manual
(Insert Firm Name) Quality System Manual Ver. 1.1 (enter implementation/revision date) Controlled Document Created date: Revised date: Revision number: Approved by: Quality System Manual Ver 1.1: (date)
More informationProcedure 14 Internal Audits
Procedure 14 Internal Audits Table of Contents 1 Introduction... 2 2 Audit Planning... 2 2.1 Head Office... 2 2.2 Critical Locations... 3 3 Conducting the Audit... 3 4 Non-conformances... 3 5 Client file
More informationContract Quality Requirements Manual SLM Issue 3
Contract Quality Requirements Manual SLM 4.06.02 Issue 3 20 th October 2015 Gary Rushforth Supply Chain Quality Sellafield Ltd Introduction Sellafield Ltd (SL) aims to deliver excellence in everything
More informationIntegrated System Procedures Legionella Control Association Statement of Compliance
Procedure No: IP-028 Rev No : 14 Rev Date : 20/07/2016 Page 1 of 7 The services offered by HBE (Healthy Built Environment) under the scope of this code of conduct are limited to: 1. Risk Assessment Services
More informationSupplier Excellence General Requirements
Supplier Ecellence General Requirements Consumer Goods General Merchandise & Non Trade Table of Contents Contents SECTION 1 - Product Design and Risk Assessment SECTION 2 - Product Control and Process
More information45. Feedlot construction delivery
Client Des i gn/ Builder Design Consultant Construction Sub-contractors and suppliers FEEDLOT DESIGN AND CONSTRUCTION 45. Feedlot construction delivery AUTHORS: Rod Davis and Ross Stafford Introduction
More information