Operating instructions Analytical and precision balances

Size: px
Start display at page:

Download "Operating instructions Analytical and precision balances"

Transcription

1 KERN & Sohn GmbH Ziegelei 1 D Balingen info@kern-sohn.com Phone: +49-[0] Fax: +49-[0] Internet: Operating instructions Analytical and precision balances KERN ALT_B-PLT_A-PLT_F Version /2011 GB ALT_B-PLT_A-PLT-F-BA-e-1130

2 GB KERN ALT_B-PLT_A-PLT_F Version /2011 Operating instructions Electronic analytical and precision balances Contents 1 Technical data Appliance overview Operating side Back and bottom side Keyboard overview Navigation buttons / numeric input Overview of display Basic instructions Proper use Improper Use Warranty Monitoring of Test Resources Basic Safety Precautions Pay attention to the instructions in the Operation Manual Personnel training Transport and storage Testing upon acceptance Packaging / return transport Unpacking, Setup and Commissioning Installation Site, Location of Use Unpacking, Scope of delivery Placing Connect and switch-on power supply Connection of peripheral devices Initial Commissioning Adjustment Adjustment with internal weight after pressing the CAL button Automatic adjustment with internal weight (factory setting) Adjustment with external adjustment weight Overwrite internal adjustment weight ALT_B-PLT_A-PLT_F-BA-e-1130

3 8 Basic Operation Switch on off balance Zeroing Simple weighing Capacity display Weighing with tare Determination of the tare weight by weighing Pre-tare deduction (PRE-TARE) Underfloor weighing Setup menu Weighing Units RS Baud rate Auto Zero Filter Stability Setting the contrast of the display Display background illumination Automatic switch-off function AUTO OFF Setting date and time Language operator guide Adjustment mode Adjustment log Main Menu Parts counting Determine reference by weighing Numeric entry of the reference weight Automatic reference optimization Density determination (Hydrostatic weighing) Density determination of solids Determining density of liquids Formula mode (only models PLT) Formulation without using the recipe data base Formulation using the recipe data base Check weighing Percent determination Entering the reference weight by weighing Numeric entering of the reference weight Animal weighing function Peak value function GLP function (Good laboratory practice)...74 ALT_B-PLT_A-PLT_F-BA-e

4 11 Data output RS 232C Technical data Pin allocation of balance output plug Interface Format Data transfer Error messages Service, maintenance, disposal Clean Service, maintenance Disposal Instant help Declaration of conformity ALT_B-PLT_A-PLT_F-BA-e-1130

5 1 Technical data KERN ALT 160-4B ALT 250-4B Weighing range (max) 160 g 250 g Readability (d) 0.1 mg 0.1 mg Reproducibility 0.1 mg 0.1 mg Linearity ± 0.3 mg ± 0.3 mg Stabilization time (typical) 4 s 4 s Minimum unit weight at piece counting Warm-up time Adjustment weight Reference quantities at piece counting Weighing Units Secondary voltage powerpack Operating temperature Humidity of air > 0.5 mg > 0.5 mg 8 hours internal 10, 25, 50, 100, freely selectable ct, dwt, g, gn, lb, mo, oz, ozt, tl (HK), tl (Singap. Malays), tl (Tw) 24 V AC, 500mA + 5 C C max. 80 % (not condensing) Housing (B x D x H) mm 210 x 340 x 330 Dimensions of windshield (B x D x H) mm Weighing pan (stainless steel) Weight kg (net) Interface 160 x 140 x 205 (inside) 190 x 195 x 225 (outside) Ø 80 mm 5.7 kg RS 232C ALT_B-PLT_A-PLT_F-BA-e

6 KERN PLT 720-3A PLT A PLT A Weighing range (max) 720 g 1200 g 6200 g Readability (d) 1 mg 1 mg 10 mg Reproducibility 1 mg 1 mg 10 mg Linearity ± 2 mg ± 2 mg ± 30 mg Stabilization time (typical) 2 s 2 s 2 s Minimum unit weight at piece counting > 5 mg > 5 mg > 50 mg Warm-up time 4 hours 8 hours 4 hours Adjustment weight Reference quantities at piece counting Weighing Units Input Voltage Secondary voltage powerpack Operating temperature Humidity of air internal 10, 25, 50, 100, freely selectable ct, dwt, g, gn, lb, mo, oz, ozt, tl (HK), tl (Singap. Malays), tl (Tw) V AC 50 Hz 24 V AC, 500mA + 5 C / + 35 C max. 80 % (not condensing) Housing (B x D x H) mm 210 x 340 x x 340 x 100 Dimensions of windshield Weighing pan (stainless steel) Weight kg (net) Interface Underfloor weighing device Ø 150, 60 high (inside) Ø 160, 70 high (outside) Ø 11 cm 4.5 kg RS 232C Eyelet - Ø 16 cm 6 ALT_B-PLT_A-PLT_F-BA-e-1130

7 KERN PLT 420-3F PLT F Weighing range (max) 420 g 4200 g Readability (d) 1 mg 10 mg Reproducibility 1 mg 10 mg Linearity ± 4 mg ± 40 mg Stabilization time (typical) 2 s 2 s Minimum unit weight at piece counting Warm-up time Adjustment weight Reference quantities at piece counting Weighing Units Input Voltage Secondary voltage powerpack Operating temperature Humidity of air > 5 mg > 50 mg 4 hours internal 10, 25, 50, 100, freely selectable ct, g, gn, lb, mo, oz, ozt, tl (HK), tl (Singap. Malays), tl (Tw), tol V AC 50 Hz 9 V 1000mA, DC + 5 C / + 35 C max. 80 % (not condensing) Housing (B x D x H) mm 210 x 340 x x 340 x 95 Dimensions of windshield Weighing pan (stainless steel) Ø 150, 60 high (inside) Ø 160, 70 high (outside) Ø 11 cm - Ø 16 cm Weight kg (net) 4.5 kg 4 kg Interface RS 232C Underfloor weighing device - ALT_B-PLT_A-PLT_F-BA-e

8 2 Appliance overview 2.1 Operating side Models ALT Models PLT, d = 1 mg 8 ALT_B-PLT_A-PLT_F-BA-e-1130

9 Models PLT, d = 10 mg Windshield Levelling screw Weighing pan Bubble level Display Cover windshield Keyboard ALT_B-PLT_A-PLT_F-BA-e

10 2.1.1 Back and bottom side 1. Weighing pan 2. RS232C-interface 3. Footscrews 4. Mains adapter connection 5. Casing screws (in models with four feet first screw out both rear feet) 6. Underfloor weighing device (remove cover) 10 ALT_B-PLT_A-PLT_F-BA-e-1130

11 2.2 Keyboard overview Key Description Description MENU button Invoke main menu How to select menu items Press until the acoustic signal gets mute Invoke setup menu Exit setup menu ON/OFF button CAL-key PRINT button TARE button Turn on/off Exit main menu Adjustment How to select menu items Calculate weighing data via interface Confirm / store settings Taring Zeroing ALT_B-PLT_A-PLT_F-BA-e

12 2.2.1 Navigation buttons / numeric input Key Description Function Navigation button Increase digit Scroll forward in menu Set decimal place Navigation button Reduce digit Scroll backwards in menu Change capital/small letters Press MENU button until the acoustic signal gets mute Position digit Navigation button Delete input Navigation button Store ESC cancel 12 ALT_B-PLT_A-PLT_F-BA-e-1130

13 2.3 Overview of display 1 Capacity display 2 Stability display 3 Zero indicator 4 Numerical display/menu 5 Unit 6 Current time 7 Current date Display Description see chap. Stability display + Chap. 8.3 Zero indicator + Chap. 8.2 Balance is in percent determination mode + Chap PC Balance is in parts counting mode + Chap H Upper limit + Chap L Lower limit DS The balance is in density determination mode + Chap g Weighing unit Gram ct Weighing unit Carat Oz Weighing unit Ounce Lb Weighing unit Pound Dwt Weighing unit Pennyweights Ozt Weighing unit Troy ounce Chap. 9.1 GN Weighing unit Grain tl 1 Weighing unit Hongkong Tael tl 2 Weighing unit Singapore Tael tl 3 Weighing unit Taiwan Tael mo Weighing unit Momme ALT_B-PLT_A-PLT_F-BA-e

14 Operator guidance: In a selected application you are guided step-by-step through that application. Selectable languages (D, GB, F, IT. ESP, P; see chap. 9.11). Display example Piece counting 8 Active application 9 Current date 0 Current time a Operation step to be carried out 14 ALT_B-PLT_A-PLT_F-BA-e-1130

15 3 Basic instructions 3.1 Proper use The balance you purchased is intended to determine the weighing value of material to be weighed. It is intended to be used as a non-automatic balcance, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing pan.. As soon as a stable weighing value is reached the weighing value can be read. 3.2 Improper Use Do not use balance for dynamic weighings. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the stability compensation. (Example: Slowly draining fluids from a container on the balance.) Do not leave permanent load on the weighing pan. This may damage the measuring system. Impacts and overloading exceeding the stated maximum load (max) of the balance, minus a possibly existing tare load, must be strictly avoided. Balance may be damage by this. Never operate balance in explosive environment. The serial version is not explosion protected. The structure of the balance may not be modified. This may lead to incorrect weighing results, safety-related faults and destruction of the balance. The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing. 3.3 Warranty Warranty claims shall be voided in case 1. Our conditions in the operation manual are ignored 2. The appliance is used outside the described uses 3. The appliance is modified or opened 4. Mechanical damage or damage by media, liquids, natural wear and tear The appliance is improperly set up or incorrectly electrically connected The measuring system is overloaded 3.4 Monitoring of Test Resources In the framework of quality assurance the measuring-related properties of the balance and, if applicable, the testing weight, must be checked regularly. The responsible user must define a suitable interval as well as type and scope of this test. Information is available on KERN s home page ( with regard to the monitoring of balance test substances and the test weights required for this. In KERN s accredited DKD calibration laboratory test weights and balances may be calibrated (return to the national standard) fast and at moderate cost. ALT_B-PLT_A-PLT_F-BA-e

16 4 Basic Safety Precautions 4.1 Pay attention to the instructions in the Operation Manual Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances. 4.2 Personnel training The appliance may only be operated and maintained by trained personnel. 5 Transport and storage 5.1 Testing upon acceptance When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage. 5.2 Packaging / return transport Keep all parts of the original packaging for a possibly required return. Only use original packaging for returning. Prior to dispatch disconnect all cables and remove loose/mobile parts. Reattach possibly supplied transport securing devices. Secure all parts such as the glass wind screen, the weighing platform, power unit etc. against shifting and damage. 16 ALT_B-PLT_A-PLT_F-BA-e-1130

17 6 Unpacking, Setup and Commissioning 6.1 Installation Site, Location of Use The balances are designed in a way that reliable weighing results are achieved in common conditions of use. You will work accurately and fast, if you select the right location for your balance. On the installation site observe the following: Place the balance on a firm, level surface Avoid extreme heat as well as temperature fluctuation caused by installing next to a radiator or in the direct sunlight Protect the balance against direct draughts due to open windows and doors Avoid jarring during weighing Protect the balance against high humidity, vapours and dust Do not expose the device to extreme dampness for longer periods of time. Non-permitted condensation (condensation of air humidity on the appliance) may occur if a cold appliance is taken to a considerably warmer environment. In this case, acclimatize the disconnected appliance for ca. 2 hours at room temperature. Avoid static charge of goods to be weighed and weighing container. Major display deviations (incorrect weighing results) may be experienced should electromagnetic fields (e.g. due to mobile phones or radio equipment), static electricity accumulations or instable power supply occur. Change location or remove source of interference. ALT_B-PLT_A-PLT_F-BA-e

18 6.2 Unpacking, Scope of delivery Remove device and accessories carefully from packaging, remove packaging material and place device at the planned work place. Verify that there has been no damage and that all packing items are present. Scope of delivery / serial accessories: Balance, see chap. 2 Mains adapter Protective cover Operating instructions Transport Securing 6.3 Placing The right place is decisive for the accuracy of the weighing results of high-resolution analytical and precision balances (see chap. 6.1). Remove transportation lock On the left lower side of the balance replace the golden-coloured screw with the silver-coloured one (see label). 18 ALT_B-PLT_A-PLT_F-BA-e-1130

19 Install weighing pan as per illustration Models ALT Models PLT, d = 1 mg Models PLT, d = 10 mg ALT_B-PLT_A-PLT_F-BA-e

20 Levelling balance Level balance with foot screws until the air bubble of the water balance is in the prescribed circle. Check levelling regularly. 6.4 Connect and switch-on power supply Before connecting the mains adapter check if the printed voltage value is the same as the local supply voltage. Only use KERN original mains adapter. Using other makes requires consent by KERN. Supply power to balance via mains adapter. The balance will carry out a self-test Then the balance is set into stand-by mode, OFF is displayed. To switch on press the ON/OFF button. During the display CAL adjustment is automatically carried out with the internal adjustment weight (see chap. 7.2). As soon as the weight display appears, the balance is ready for weighing. To switch off, press the ON/OFF button again. The balance returns into standby mode. 6.5 Connection of peripheral devices Before connecting or disconnecting of additional devices (printer, PC) to the data interface, always disconnect the balance from the power supply. With your balance, only use accessories and peripheral devices by KERN, as they are ideally tuned to your balance. 6.6 Initial Commissioning In order to obtain exact results with the electronic balances, your balance must have reached the operating temperature (see warming up time chap. 1). During this warming up time the balance must be connected to the power supply (mains, accumulator or battery). The accuracy of the balance depends on the local acceleration of gravity. Strictly observe hints in chapter Adjustment. 20 ALT_B-PLT_A-PLT_F-BA-e-1130

21 7 Adjustment As the acceleration value due to gravity is not the same at every location on earth, each balance must be coordinated - in compliance with the underlying physical weighing principle - to the existing acceleration due to gravity at its place of location (only if the balance has not already been adjusted to the location in the factory). This adjustment process must be carried out for the first commissioning, after each change of location as well as in case of fluctuating environment temperature. To receive accurate measuring values it is also recommended to adjust the balance periodically in weighing operation. Observe stable environmental conditions. A warming up time (see chapter 1) is required for stabilization. Ensure that there are no objects on the weighing pan. Issue of an adjustment log, see chap The balances have been set to Automatic adjustment (see chap. Fehler! Verweisquelle konnte nicht gefunden werden.) by factory. If necessary, in the menu the following possibilities of adjustment can be activated. Internal adjustm. External adjustm. Technical adjustm. Autom. adjustm. Adjustment with internal weight after pressing CAL Adjustment with external weight Overwrite internal adjustment weight Automatic adjustment with internal weight. ALT_B-PLT_A-PLT_F-BA-e

22 Setting adjustment mode: In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Adjustment mode. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the desired setting. Display Description Procedure see chap. Internal adjustm. Adjustment with internal adjustment weight Chap. 7.1 External adjustm. Adjustment with external adjustment weight Chap. 7.3 Technical adjustm. Autom. Adjustm. Overwrite internal adjustment weight Automatic adjustment with internal adjustment weight Chap. 7.4 Chap. 7.2 Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. 22 ALT_B-PLT_A-PLT_F-BA-e-1130

23 7.1 Adjustment with internal weight after pressing the CAL button Condition: Menu setting Internal adjustm., see chap. 7 In weighing mode press the CAL button, adjustment will take place automatically. After successful adjustment the balance automatically returns to weighing mode. In case of an adjustment error (e.g. objects on the weighing pan) the display will show an error message CAL but, repeat adjustment using the CAL button. 7.2 Automatic adjustment with internal weight (factory setting) Condition: Menu setting Autom. adjustm., see chap. 7 The automatic adjustment with internal weight (see chap. 7.1) is started automatically, if the balance after the weighing balance was disconnected from the mains after pressing ON/OFF in stand-by mode after a temperature change of 1.5 C with non loaded weighing pan / zero display after a time interval of 20 min with non loaded weighing pan / zero display The automatic adjustment function is always enabled. However you can make a manual adjustment at any time with the internal or an external weight, see chap. 7.1 or chap ALT_B-PLT_A-PLT_F-BA-e

24 7.3 Adjustment with external adjustment weight Condition: Menu setting External adjustm., see chap. 7 At the models with internal adjustment weight the adjustment with external weight is not recommended. Information about test weights you will find in the internet under Ensure that there are no objects on the weighing pan. In weighing mode press the CAL button. Wait until the weighed value for the required adjustment weight appears flashing. During the flashing display put the required adjustment weight carefully in the center of the weighing pan. The flashing display disappears. After successful adjustment the balance automatically returns to weighing mode. Take away adjustment weight 24 ALT_B-PLT_A-PLT_F-BA-e-1130

25 7.4 Overwrite internal adjustment weight Overwriting is restricted to specialist staff possessing well acquainted with the workings of weighing scales. Information about test weights you will find in the internet under Call up menu item Techn. adjustment, see chap. 7. To confirm press the PRINT button and keep it pressed until the acoustic signal gets mute. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. Ensure that there are no objects on the weighing pan. Press the CAL key Wait until the weighing value of the adjustment weight appears flashing. During the flashing display put the required adjustment weight carefully in the center of the weighing pan. The flashing display disappears. Wait for stability display, remove adjustment weight. Keep the PRINT button pressed until the acoustic signal gets mute. The internal adjustment weight is overwritten. After successful overwriting, the balance automatically returns to weighing mode. ALT_B-PLT_A-PLT_F-BA-e

26 8 Basic Operation 8.1 Switch on off balance Start-up: In stand-by mode (see chap. 6.4) press ON/OFF button. As soon as the weight display appears, the balance is ready for weighing. Switching off: Press ON/OFF. The balance changes into standby mode, that means that the balance is now in state ready-for-operation.. To switch-off the balance completely, separate balance from power supply. 8.2 Zeroing Unload the balance Press the TARE key. The zero display and the indicator [-0-] will appear. 26 ALT_B-PLT_A-PLT_F-BA-e-1130

27 8.3 Simple weighing In order to obtain exact weighing results, your balance must have reached the operating temperature (see warming up time chap. 1). Wait for zero display, reset to zero using TARE. Place goods to be weighed on balance. Wait until the stability display appears [ ]. Read weighing result. When an optional printer is connected, the weighing value can be edited. Printout examples (KERN YKB-01N): :41:17 Current date/time Weight: g Measuring Value 8.4 Capacity display The capacity display [ ] runs from below to above and proceeds according to the loaded weight on the balance. Its full height is reached at maximum load. This is an analogue display of the current allocation of the weighing area. ALT_B-PLT_A-PLT_F-BA-e

28 8.5 Weighing with tare Determination of the tare weight by weighing The dead weight of any weighing container may be tared away by pressing a button, so that the following weighing procedures show the net weight of the goods to be weighed. Put weighing container on the weighing pan. Wait until stability display [ ] appears and then press the TARE-button; Tare is displayed. After standstill control the zero display appears. The weight of the container is now internally saved. Note: Weigh the material. Wait until the stability display appears [ ]. Read net weight. When the balance is unloaded the saved taring value is displayed with negative sign. To delete the stored tare value, remove load from weighing pan and press the TARE button. Tare is displayed, wait until the zero display appears. The taring process can be repeated any number of times. The limit is reached when the whole weighing range is exhausted. 28 ALT_B-PLT_A-PLT_F-BA-e-1130

29 8.5.2 Pre-tare deduction (PRE-TARE) The known dead weight of a weighing container can be tared off by entering its weight as pre-tare deduction in order to ensure the net weight of the goods to be weighed in subsequent weighing procedures is always displayed. In weighing mode press the TARE button and keep it pressed until the acoustic signal gets mute. Manual Tare will be displayed. Enter the known tare weight, e.g. 10 g and acknowledge with PRINT button. Numerical input, see chap The entered weight will be stored as tare weight and displayed with negative sign. Put the filled weighing container on the balance, the net weight will be displayed. The tare value remains stored until it is deleted by the TARE button or the balance is separated from the power supply. ALT_B-PLT_A-PLT_F-BA-e

30 8.6 Underfloor weighing Objects unsuitable for placing on the weighing scale due to size or shape may be weighed with the help of the flush-mounted platform. Proceed as follows: Switch off the balance. Open closing cover (1) at the balance bottom. Suspend hook for underfloor weighing carefully and completely. Place weighing balance over an opening. Attach load to hook and carry out weighing procedure. CAUTION Always ensure that all suspended objects are stable enough to hold the desired goods to be weighed safely (danger of breaking). Never suspend loads that exceed the stated maximum load (max) (danger of breaking) Always ensure that there are no persons, animals or objects that might be damaged underneath the load. After completing the underfloor weighing the opening on the bottom of the balance must always be closed (dust protection). 30 ALT_B-PLT_A-PLT_F-BA-e-1130

31 9 Setup menu In the setup menu, the balance settings can be modified. This way, the balance can be adjusted to individual weighing requirements. Navigation in the menu: Access to menu In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. 2 sec. How to select menu items Use the navigation buttons to select the individual menu items one by one. The cursor ( ) displays the current setting. Change settings Acknowledge selected menu item using PRINT button, the current setting is displayed. Each time the navigation buttons are pressed the next setting will be displayed. Save settings Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to menu mode as follows. Exit menu/ back to weighing mode Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. ALT_B-PLT_A-PLT_F-BA-e

32 Menu overview Menu item Selection Description Weight units g Gram (see chap. 9.1) ct Carat Oz Ounce Lb Pound Dwt Pennyweights Ozt Troy ounce GN Grain tl 1 Hongkong-Teal tl 2 Singapur-Teal tl 3 Taiwan-Teal mo Momme Serial output (see chap. 9.2) Continuous Continuous output Baud rate (see chap. 9.3) Auto zero Automatic zero point correction (see chap. 9.4) Filter (see chap. 9.5) Stability (see chap. 9.6) On demand Generic printer Printer Tlp On demand - Glp Generic print. - Glp Printer Tlp - Glp 1200 Baud 2400 Baud 4800 Baud 9600 Baud Auto zero OFF Auto zero 1 Auto zero 2 Auto zero 3 Auto zero 3E Filter 1 Filter 2 Filter 3 Stability 1 Stability 2 Stability 3 Output of stable weighing values after pressing PRINT button Not documented Not documented GLP conformant printouts after pressing the PRINT button Not documented Not documented Transfer speed Auto Zero switched off Auto Zero range ± ½ Digit Auto Zero range ± 3 Digits Auto Zero range ± 7 Digits Auto Zero range ± 7 digits in the whole weighing range Setting for dispensing Sensitive and fast, very quiet set-up location. Robust but slow, busy set-up location. Standstill control fast / very quiet set-up location Standstill control fast + exact / quiet set-up location Standstill control exact /very set-up location. 32 ALT_B-PLT_A-PLT_F-BA-e-1130

33 Contrast adjustment (see chap. 9.7) Backlight (see chap. 9.8) Timer OFF Automatic switch-off function in stand-by mode (see chap. 9.9) Time and date (see chap Language (see chap. 9.11) Calibration mode (see chap. 9.12) 1-15 Setting the contrast of the display on off Auto Disable 2 minutes 5 minutes 15 minutes English / Deutsch Français Español Português English Italiano External calibration Auto calibration Background illumination on Background illumination off Backlighting automatically switched off 3 seconds after achieving stable weighing value. Changes in weight or pressing of keys will automatically result in backlight switching on again. AUTO-OFF switched off AUTO-OFF after 2 minutes without changing the weight AUTO-OFF after 5 minutes without changing the weight AUTO-OFF after 15 minutes without changing the weight Setting date and time Language operator guide Adjustment with external weight Automatic adjustment with internal weight Calibration info (see chap. 9.13) Return Internal calibration Technical calib. Adjustment with internal weight after pressing CAL Overwriting the internal adjustment weight Record output of the last adjustment Back to weighing mode ALT_B-PLT_A-PLT_F-BA-e

34 9.1 Weighing Units According to the requirements the balance can be switched over into different units. Selected weighing unit will be retained even after disconnection from the mains. In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Weight units. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the desired setting. Symbol Weighing unit Conversion factor 1g = g Gram 1. ct Carat 5. Oz Ounce Lb Pound Dwt Pennyweights Ozt Troy ounce GN Grain tl 1 Hongkong-Teal tl 2 Singapur-Teal tl 3 Taiwan-Teal mo Momme Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. 34 ALT_B-PLT_A-PLT_F-BA-e-1130

35 9.2 RS232 In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Serial output. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the desired setting. Display Continuous On demand Generic printer Printer Tlp On demand - Glp Generic print. - Glp Printer Tlp - Glp Description Continuous data output Output of stable weighing values after pressing PRINT key Not documented Not documented GLP conformant printouts after pressing the PRINT button Not documented Not documented Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. ALT_B-PLT_A-PLT_F-BA-e

36 9.3 Baud rate In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Baud rate. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the desired setting. Selectable 1200, 2400, 4800, 9600 baud. Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. 36 ALT_B-PLT_A-PLT_F-BA-e-1130

37 9.4 Auto Zero Under this menu item the automatic zero point correction can be switched on or off. In switched-on-state the zero point is automatically corrected at drift or when dirty. Note: In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the stability compensation. (e.g. slow flow of liquids from a container placed on the balance, evaporating processes). When apportioning involves small variations of weight, it is advisable to switch off this function. In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Auto Zero. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the desired setting. Display Auto Zero off Description Auto Zero switched off Auto Zero 1 Auto Zero range ± ½ Digit Auto Zero 2 Auto Zero range ± 3 Digits Auto Zero 3 Auto Zero range ± 7 Digits Auto Zero 3E Auto Zero range ± 7 digits in the whole weighing range Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. ALT_B-PLT_A-PLT_F-BA-e

38 9.5 Filter This menu item allows the balance to be set according to specific ambient conditions and measuring purposes. In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Filter. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the desired setting. Display Description Filter 1 Setting for dispensing Filter 2 The balance reacts quickly and in a sensitive manner, quiet set-up location. Filter 3 The balance reacts slowly and in a robust manner, busy set-up location Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. 38 ALT_B-PLT_A-PLT_F-BA-e-1130

39 9.6 Stability In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Stability. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the desired setting. Display Description Stability 1 Standstill control fast - very quiet set-up location Stability 2 Standstill control fast + exact quiet set-up location Stability 3 Standstill control exact / set-up location. Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. ALT_B-PLT_A-PLT_F-BA-e

40 9.7 Setting the contrast of the display To set the contrast of the display you can choose between 15 values. In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Contrast adjustment. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the desired setting. Display Description 0 small contrast 15 high contrast Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. 40 ALT_B-PLT_A-PLT_F-BA-e-1130

41 9.8 Display background illumination In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Backlight. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the desired setting. Display Auto Description Backlighting automatically switched off 3 seconds after achieving stable weighing value. Changes in weight or pressing of keys will automatically result in backlight switching on again On Background illumination on off Background illumination on Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. ALT_B-PLT_A-PLT_F-BA-e

42 9.9 Automatic switch-off function AUTO OFF In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Timer off. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the desired setting. Display Description Disabled AUTO-OFF switched off 2 minutes AUTO-OFF after 2 minutes without changing the weight 5 minutes AUTO-OFF after 5 minutes without changing the weight 15 minutes AUTO-OFF after 15 minutes without changing the weight Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. 42 ALT_B-PLT_A-PLT_F-BA-e-1130

43 9.10 Setting date and time In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Time and date. Acknowledge using PRINT button, the current setting is displayed. Use navigation buttons to select the required format. DD-MM: day / month MM-DD: month / day Acknowledge the format with the PRINT button and set date and time as follows. The active digit e.g. 25 is shown underlined. Use the navigation buttons to set the day and confirm using the PRINT button. The active digit wanders to the month, (is shown underlined). Use the navigation buttons to set the month and confirm using the PRINT button. Set year, hours, minutes and seconds in the same way. After finishing the input, press the PRINT button and keep it pressed until the acoustic signal gets mute. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. The set date and time are displayed. ALT_B-PLT_A-PLT_F-BA-e

44 9.11 Language operator guide In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Language. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the desired setting. Language Deutsch Français Español Português English Italiano Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. 44 ALT_B-PLT_A-PLT_F-BA-e-1130

45 9.12 Adjustment mode In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Calibration mode. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the desired setting. Display Description Procedure see chap. Internal adjustm. Adjustment with internal weight after pressing the CAL button + Chap. 7.1 External adjustm. Adjustment with external adjustment weight + Chap. 7.3 Technical adjustm. Autom. adjustm. Overwrite internal adjustment weight Automatic adjustment with internal adjustment weight + Chap Chap. 7.2 Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to weighing mode as follows. Press the MENU button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. ALT_B-PLT_A-PLT_F-BA-e

46 9.13 Adjustment log This function helps to print out a record of the last adjustment. Make sure that the communication parameter of balance and printer are the same. Communication parameters, see chap. Fehler! Verweisquelle konnte nicht gefunden werden. and 9.3 In weighing mode press the MENU button and keep it pressed until the acoustic signal gets mute. The setup menu is displayed. Use the navigation buttons to select the menu item Calibration info. Confirm with PRINT button; date, time, adjustment type and deviation of the last adjustment are displayed. If you connect an optional printer you can also print these data by pressing the PRINT key. Printout example (KERN YKB-01N): :41:17 Current date/time Calibration: :11:17 Date/time of the last adjustment Internal calib. Type of adjustment Corr. : 0.21 g Deviation from last adjustment Press the ON/OFF key. Weighing balance returns to menu. Either make more adjustments in the menu if required or press ON/OFF button anew; the balance will return into weighing mode. 46 ALT_B-PLT_A-PLT_F-BA-e-1130

47 10 Main Menu Navigation in the menu: Access to menu In weighing mode press MENU button. The master menu will be displayed. How to select menu items Use the navigation buttons to select the individual menu items one by one. The cursor ( ) displays the current setting. Change settings Acknowledge selected menu item using PRINT button, the current setting is displayed. Each time the navigation buttons are pressed the next setting will be displayed. Save settings Take over selection using the PRINT button. Weighing balance returns to menu. Either make more settings in the menu or go back to menu mode as follows. Exit menu/ back to weighing mode Press the ON/OFF key. ALT_B-PLT_A-PLT_F-BA-e

48 10.1 Parts counting Before the balance can count parts, it must know the average part weight (i.e. reference). Proceed by putting on a certain number of the parts to be counted. The balance determines the total weight and divides it by the number of parts, the socalled reference quantity. Counting is then carried out on the basis of the calculated average piece weight. As a rule: The higher the reference quantity the higher the counting exactness Determine reference by weighing In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select the menu item Piece counting. Acknowledge using PRINT button, the currently set reference quantity is displayed. Use the navigation buttons to select the desired setting. Display Description 10 off Reference piece number off Reference piece number off Reference piece number off Reference piece number 100 Manual Numerical input of reference weight, see chap ALT_B-PLT_A-PLT_F-BA-e-1130

49 If necessary place a weighing container, confirm the set reference piece number by pressing the PRINT button. Place as many pieces to add-up as required by the set reference piece number. Acknowledge using PRINT button and wait for stability display. As soon as the weighing result is stable, the determined average piece weight will be taken over as reference weight. The currently placed weight W, the reference weight MPW and the piece number PCS are displayed. Remove reference weight. The balance is now in parts counting mode counting all units on the weighing pan. ALT_B-PLT_A-PLT_F-BA-e

50 If it was impossible to determine a reference due to instable goods to be weighed or an insufficient reference weight, the following display will appear during reference calculation. Smallest counting weight not achieved Increase the counted weight or select a balance with high resolution or If in the display Add pieces.. appears, the balance asks for a reference optimisation, as the placed number of pieces was not sufficient for a correct reference calculation. Place more parts, but at least the double quantity. Press the PRINT button, the reference is calculated anew. The placed quantity is always too small, add more parts (double quantity) and acknowledge using the PRINT button. Repeat the procedure until the piece counter display appears. Placed quantity sufficient for reference determination. Remove reference weight. The balance is now in parts counting mode counting all units on the weighing pan. 50 ALT_B-PLT_A-PLT_F-BA-e-1130

51 Carry out parts counting After having calculated the reference, place the pieces which will be counted. The currently placed weight G, the reference weight AUW and the calculated piece number St. are displayed. The display value can be printed out by connecting an optional printer. Printout example (KERN YKB-01N): :41:17 Current date/time PCS 20 Calculated piece number Weight: 199,9985 g Weight placed on balance MPW: g Reference weight Return to weighing mode Press the ON/OFF key ALT_B-PLT_A-PLT_F-BA-e

52 Numeric entry of the reference weight If the piece weight (reference) is known, it can be entered directly. As the balance in this method needs not to calculate any reference, the balance after confirming the reference piece weight will be directly in parts counting mode. In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select the menu item Piece counting. Acknowledge using PRINT button, the currently set reference quantity is displayed. Use the MENU button to select the Manual setting. Confirm by pressing the PRINT button. Use the navigation buttons (see chap ) to enter the known reference piece weight in grams. To set a decimal point press the CAL button long time. The input is deleted by pressing the TARE button a longer time. Confirm by pressing the PRINT button. From here on the balance is in parts counting mode and counts all pieces which are placed on the weighing pan (see chap Carry our parts counting ). If the minimum parts weight is not reached, an error message will appear. Use the ON/OFF button to return to the weighing mode and restart the procedure. Return to weighing mode Press the ON/OFF key 52 ALT_B-PLT_A-PLT_F-BA-e-1130

53 Automatic reference optimization In order to improve the counting exactness, the reference can be optimised by adding more pieces. At every reference optimisation, the reference weight is calculated anew. As the additional pieces increase the base for the calculation, the reference also becomes more exact. Leave the piece number on the weighing pan after setting the reference weight Duplicate the number of pieces on the weighing pan and wait until the acoustic signal sounds. The reference weight is calculated anew. Either repeat the reference optimisation by adding more pieces (max. 255 pieces) or start the counting process. The automatic reference optimisation is not active when the reference weight is entered numerically. ALT_B-PLT_A-PLT_F-BA-e

54 10.2 Density determination (Hydrostatic weighing) Density is the relationship of weight [g] : volume [cm 3 ]. The weight is determined by weighing the sample in air. The volume results from the ascending force [g] of the sample dipped in a liquid. The density [g/cm 3 ] of that liquid is known (principle of Archimedes). The density is determined with help of the underfloor weighing device. We recommend to switch off the automatic adjustment in the setup menu, see chap Density determination of solids Prepare the balance as follows: Switch off the balance Remove the weighing pan and carefully turn over the weighing balance. Suspend hook for underfloor weighing (optional) Place weighing balance over an opening Prepare suspension device Fill measuring liquid e.g. water in a vessel e.g. beaker and temper it. Calculate density: In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select the menu item Density. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select setting Solid body. Confirm using the PRINT button, the set density of the measuring liquid is displayed (factory setting for dest. water at 20 C). Use the navigation buttons (see chap ) to enter the current density of the measuring liquid. For water see the following density table. Confirm with PRINT button, the display for calculation of Weight in air is displayed. 54 ALT_B-PLT_A-PLT_F-BA-e-1130

55 Suspend sample with suspension device at the flush-mounted hook. Wait for stability display, take over the weight value using PRINT button. The display for determination of the "sample in water appears. Immerse the sample without bubbles developing. Make sure that the sample does not touch the beaker. Wait for stability display, take over the weight value using PRINT button. The density of the sample is shown. ALT_B-PLT_A-PLT_F-BA-e

56 When an optional printer is connected, the displayed value can be edited using PRINT. Printout example (KERN YKB-01N): :14:57 d: g/cm 3 If at the density determination errors have appeared, d----- is displayed. 1. Back to density determination mode, press MENU button. 2. Back to weighing mode, press ON/OFF button. 56 ALT_B-PLT_A-PLT_F-BA-e-1130

57 Density table of water: * the asterisk means that the cipher left from the comma is reduced by 1. Table from "Mass determination" by M. Kochsiek, M. Gläser ALT_B-PLT_A-PLT_F-BA-e

58 Determining density of liquids For density determination of liquids, a sinker with known density is used (optionally available). The sinker is weighed first in air and then in the liquid whose density is to be determined. From the weight difference results the buoyancy from where the software calculates the density. Preparation: Fill sample liquid into a vessel, e.g. a pitcher. Heat sample liquid until temperature is constant. Prepare a sinker with known density Calculate density: In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select the menu item Density. Acknowledge using PRINT button, the current setting is displayed. Use the navigation buttons to select the setting Liquid. Confirm using the PRINT button, the set density of the sinker is displayed (factory setting g/cm 3 ). Use the navigation buttons (see chap ) to enter the current density of the sinker. Confirm by pressing the PRINT button. The display for weight determination of the "Sinker in air appears. 58 ALT_B-PLT_A-PLT_F-BA-e-1130

59 Suspend sinker with suspension device at the flush-mounted hook. Wait for stability display, take over the weight value using PRINT button. The display for weight determination of the "Sinker in sample liquid appears. Immerse the sample without bubbles developing. Make sure that the sample does not touch the beaker. Wait for stability display, take over the weight value using PRINT button. The density of the sample is shown. ALT_B-PLT_A-PLT_F-BA-e

60 If at the density determination errors have appeared, d----- is displayed. When an optional printer is connected, the displayed value can be edited using PRINT. Printout example (KERN YKB-01N): :14:57 d : g/cm 3 1. Back to density determination mode, press MENU button. 2. Back to weighing mode, press ON/OFF button. 60 ALT_B-PLT_A-PLT_F-BA-e-1130

61 10.3 Formula mode The formula function allows weighing of components which are in a certain relation one to the other. For check purpose, the weight of all components, as well as the total weight (TOT) can be printed out. The balance works with a separated memory for the weight of the weighing container and of the formula components Formulation without using the recipe data base Select formula mode Manual In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select the menu item Formulation. Confirm by pressing the PRINT button. Confirm by pressing the PRINT button. The display for weighing the first component appears. Weighing components Tare when using a weighing container Weighing the first component (e.g. 15 g). Confirm by pressing the PRINT button. The weight is added to the summation memory and printed if an optional printer is connected. ALT_B-PLT_A-PLT_F-BA-e

62 Weighing the second component (e.g. 5 g). Confirm by pressing the PRINT button. The weight is added to the summation memory and printed if an optional printer is connected. If required, weigh more components (max. 99) as described above. Complete Formulation process Press the PRINT button and keep it pressed until the acoustic signal gets mute. The total weight (TOT:) of all components will be displayed and edited on the printer. Printout example (KERN YKB-01N): :14:57 Date/time Manual Recipe mode g Weighing 1. component g Weighing 2. component T = g Total weight 1. Back to formula mode, press the ON/OFF button and start the next Formulation. 2. Back to weighing mode, press ON/OFF button repeatedly. 62 ALT_B-PLT_A-PLT_F-BA-e-1130

63 Formulation using the recipe data base Store recipes The balance contains a recipe data base, where maximally 99 recipes each with 20 components can be filed. Select formula mode In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select the menu item Formula. Confirm by pressing the PRINT button. Define recipe and components 1. Use the navigation buttons to select the memory space number (e.g. 01) for the recipe. Press the PRINT button and keep it pressed until the acoustic signal gets mute. The display for entering the recipe name appears. 2. Use the navigation buttons (see chap ) to enter the recipe name (max. 20 characters). 3. Confirm by pressing the PRINT button. The display for entering the first component name appears. 4. Use the navigation buttons (see chap ) to enter the component name (max. 11 characters). ALT_B-PLT_A-PLT_F-BA-e

64 5. Confirm by pressing the PRINT button. The display to enter the quantity appears. 6. Use the navigation buttons (see chap ) to enter quantity. 7. Confirm by pressing the PRINT button. 8. To enter more components (max. 20) repeat step 3 6 respectively. 9. Once having entered all components, use the ON/OFF button to exit the formula entry mode. Back to weighing mode, press ON/OFF button anew. 64 ALT_B-PLT_A-PLT_F-BA-e-1130

65 Invoke and work off the recipes After invoking a stored recipe (see chap ) the balance will be ready at once for weighing the components. Name and nominal value of the respective component are displayed. In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select the menu item Formula. Confirm by pressing the PRINT button. Use navigation buttons to select the required recipe. Acknowledge using PRINT button, the first component and its nominal value are displayed. Using the navigation buttons, all components and their nominal value can be displayed. Confirm using the PRINT button, the display for weighing the first component appears. Tare when using a weighing container Start weighing. Pay particular attention to the display, because the balance does not verify if the weighed weight matches with the nominal value. If the nominal weight is reached, press PRINT button. The display for weighing the second component appears. At the same time the header and the weight value of the 1. component are printed out. ALT_B-PLT_A-PLT_F-BA-e

66 Weigh-in the displayed nominal value of the second component. If the nominal weight is reached, press PRINT button. The display for weighing the next component appears. At the same time the header and the weight value of the 2. component are printed out. After weighing and confirming the last component, automatically the total weight (TOT:) of all components is displayed and printed out. Printout example (KERN YKB-01N): :14:57 Cake Name receipt g Weighing 1. component Salt Name 1. component g Weighing 2. component Sugar Name 2. component g Weighing 3. component ABC Name 3. component T = g Total weight Back to formula mode, press the ON/OFF button and start the next recipe. Back to weighing mode, press ON/OFF button anew. 66 ALT_B-PLT_A-PLT_F-BA-e-1130

67 10.4 Check weighing In checkweighing an upper and a lower limit value can be established to ensure that the weighed goods are exactly within the established tolerance limits. The tolerance mark ( ) and an acoustic signal (selectable) show, if the weighed material is within the two tolerance limits. Display of the results 1. Lower and upper limit value 0 Tolerance marker Tone Assessment no Load exceeds specified tolerance yes Load within specified tolerance no Load below specified tolerance 2. Lower limit value > 0 and upper limit value = 0 Tolerance marker Tone Assessment yes Weighed goods > lower limit value no Weighed goods lower limit value 3. Lower limit value = 0 and upper limit value > 0 Tolerance marker Tone Assessment no Weighed goods > upper limit value yes Weighed goods upper limit value ALT_B-PLT_A-PLT_F-BA-e

68 Settings In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select the menu item Checkweighing. Press PRINT button to confirm, the display for entering the lower limit value will appear. Use the navigation buttons (see chap.2.2.1) to enter the lower limit value, e.g g. Press PRINT button to confirm, the display for entering the upper limit value will appear. Use the navigation buttons (see chap.2.2.1) to enter the upper limit value, e.g g. Confirm using the PRINT button, the display to adjust the signal tone appears. Use the MENU-button to select the desired setting On: Acoustic signal switched on Off: Signal tone switched off Confirm by pressing the PRINT button. From now the balance is in checkweighing mode. 68 ALT_B-PLT_A-PLT_F-BA-e-1130

69 Start tolerance check Tare when using a weighing container Put on goods to be weighed, tolerance control is started Load below specified tolerance Load within specified tolerance Load exceeds specified tolerance When an optional printer is connected, the displayed value can be edited using PRINT. Printout examples (KERN YKB-01N): Load below specified tolerance Load within specified tolerance Load exceeds specified tolerance :14: :14: :14:57 Lim.1 : g Lim.1 : g Lim.1 : g Lim. 2 : g Lim. 2 : g Lim. 2 : g Weight : 8,900 g Weight : g Weight : 11,700 g TEST : KO! --- TEST : OK TEST : KO! +++ Return to weighing mode Press the ON/OFF key ALT_B-PLT_A-PLT_F-BA-e

70 10.5 Percent determination Percent determination allows weight display in percent, in relation to a reference weight Entering the reference weight by weighing In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select the menu item Percent weigh.. Confirm with the PRINT button, the currently set mode will be displayed. Use the navigation buttons to select setting Automatic. If using a weighing container, put this before pressing the PRINT button. The taring process is automatically started. Press the PRINT key. Place the reference weight (=100 %) and press the PRINT button. As soon the weighing value is stable, the determined weight will be taken over as reference (100%). From now the balance is in percent determining mode. Place weighed goods, the result display will appear. W% Weight of the sample in percentage W Weight of the sample in grams REF: Reference weight (100%) When an optional printer is connected, the displayed value can be edited using PRINT. Printout example (KERN YKB-01N): :14:57 Perc % Weight of the sample in percentage Weight: g Weight of the sample in grams Refer.: g Reference weight (100%) 70 ALT_B-PLT_A-PLT_F-BA-e-1130

71 Numeric entering of the reference weight In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select the menu item Percent determin.. Confirm with the PRINT button, the currently set drying mode will be displayed. Use the navigation buttons to select setting Manual. Confirm by pressing the PRINT button. Use the navigation buttons (see chap ) to enter the reference weight (100 %) in grams. Confirm input by pressing the PRINT button. From now the balance is in percent determining mode. Place weighed goods, the result display will appear. W% Weight of the sample in percentage W Weight of the sample in grams REF: Reference weight (100%) When an optional printer is connected, the displayed value can be edited using PRINT. Printout example (KERN YKB-01N): :14:57 Perc % Weight of the sample in percentage Weight: g Weight of the sample in grams Refer.: g Reference weight (100%) Return to weighing mode Press the ON/OFF key ALT_B-PLT_A-PLT_F-BA-e

72 10.6 Animal weighing function The animal weighing function can be applied for busy weighings. During a defined period the mean value of the weighing results is formed. The more unquiet the weighed item, the longer the measuring time should be selected. In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select the menu item Animal weigh.. Confirm with the PRINT button, the currently set measuring time will be displayed. Use the navigation buttons to select the wanted measuring time (5 90 s) and confirm with PRINT button. Put upon weighing goods and press the PRINT button. In the display runs a Countdown of the set measuring time. The average value of the weighing results is displayed and remains displayed on the screen. When an optional printer is connected, the displayed value can be edited using PRINT. Printout example (KERN YKB-01N): :14:57 Time = 20 sec Measuring time A: g Weighing result For other weighing procedures press ON/OFF button 1x Return to weighing mode: Press the ON/OFF button 2x 72 ALT_B-PLT_A-PLT_F-BA-e-1130

73 10.7 Peak value function This function displays the highest load value (peak value) of a weighing. The peak value remains in the display until it will be deleted. In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select menu item Maximum load. Confirm using PRINT button, the taring process is automatically started. Tare will be shortly displayed. From now on the balance is in peak value mode. Load weighing pan. The maximum load value is displayed. The peak value remains in the display until the TARE button is pressed. Then the balance is ready for further measurements. When an optional printer is connected, the displayed value can be edited using PRINT. Printout example (KERN YKB-01N): :14:57 Max.: g Peak value Return to weighing mode: Press the ON/OFF key. ALT_B-PLT_A-PLT_F-BA-e

74 10.8 GLP function (Good laboratory practice) In the GLP settings, information is defined, which will be edited in the measurement records. In weighing mode press MENU button. The master menu will be displayed. Use the navigation buttons to select the menu item GLP.. Confirm by pressing the PRINT button. The display to enter the balance identification number appears. Use the navigation buttons (see chap ) to enter the balance ID (max. 18 characters). Confirm by pressing the PRINT button. The display for entering the user ID appears. Use the navigation buttons (see chap ) to enter the user ID (max. 18 characters). Confirm by pressing the PRINT button. The display for entering the project ID appears. Use the navigation buttons (see chap ) to enter the project ID (max. 18 characters). To save all the information press the PRINT button and keep it pressed until the acoustic signal gets mute. The balance returns automatically into weighing mode. 74 ALT_B-PLT_A-PLT_F-BA-e-1130

75 For GLP conformant printouts activate the menu setting PRINT button_glp, see chap. 9.2 Printout example (KERN YKB-01N): :14:57 Balance ID: TEST 1 User ID: Miller Project ID: 789 G.L.P. Parameter Weight: Signature: g Weighing data G.L.P. Parameter ALT_B-PLT_A-PLT_F-BA-e

76 11 Data output RS 232C RS232C The following conditions must be met to provide successful communication between the weighing balance and the printer. Use a suitable cable to connect the weighing balance to the interface of the printer/pc. Faultless operation requires an adequate KERN interface cable (optional). The baud rates of balance and printer must match (see chap.9.3). In the setup menu (see chap.9.2) activate the desired data output, you can select - Continuous data output - Output of stable weighing values after pressing the PRINT button - GLP conformant printouts after pressing the PRINT button 11.1 Technical data 8-bit ASCII Code 8 data bits, 1 stop bit, no parity bit Baud rate optional from Baud 11.2 Pin allocation of balance output plug RS 23 2C R S C Pin 1 Power +5V Pin 2 Tx Signal Pin 3 Rx Signal Pin 4 busy signal Pin 5 GND Pin 4-6 Transmission to PC 76 ALT_B-PLT_A-PLT_F-BA-e-1130

77 11.3 Interface Balance PC 25-pole RS232C RS2 RS232C RS2 32C RS2 32C RS23 2C RS232C RS232C Balance PC 9-pole RS232C RS2 RS232C 2 3 RS2 32C RS23 2C 5 6 RS232C 4 Balance - printer Balance Printer Input data Busy signal GND ALT_B-PLT_A-PLT_F-BA-e

78 11.4 Format Data transfer The data set consists of the following 14 characters: 1. Character Sign -/ blank (weighing value) 2-9. Character Weight or other data Character Weighing unit 13. Character Stability display 14. Character Carriage return 15. Character Line feed Weighing mode (continuous output or output after pressing the PRINT button) r Character Weight Weighing unit Stability CR LF 78 ALT_B-PLT_A-PLT_F-BA-e-1130

79 12 Error messages ERR01 ERR02 ERR03 ERR04 ERR05 ERR06 ERR07 ERR08 UNLOAD : CAL But Weight value instable or zeroing not possible. Check the environmental conditions. Adjustment error, e.g. instable environmental conditions Adjustment error e.g. incorrect adjustment weight} Piece weight too small/instable Data transfer not possible, as weighing value is instable. Check the environmental conditions. Weighing value in density determining mode instable. Check the environmental conditions. Weighing value in percentage determining mode instable. Check the environmental conditions. Error at internal adjustment Weighing value in formula mode instable. Check the environmental conditions. Weighing range not achieved. Check position of the weighing pan. Adjust balance. Weighing range exceeded, placed load exceeds the capacity of the balance. Unload the balance. Weighing range not reached, e.g. weighing pan not in place ALT_B-PLT_A-PLT_F-BA-e

80 13 Service, maintenance, disposal Before any maintenance, cleaning and repair work disconnect the appliance from the operating voltage Clean Please do not use aggressive cleaning agents (solvents or similar agents), but a cloth dampened with mild soap suds. Ensure that no liquid penetrates into the device. Polish with a dry soft cloth. Loose residue sample/powder can be removed carefully with a brush or manual vacuum cleaner. Spilled weighing goods must be removed immediately Service, maintenance The appliance may only be opened by trained service technicians who are authorized by KERN. Ensure that the balance is regularly calibrated, see chap. Testing instruments control Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used. 80 ALT_B-PLT_A-PLT_F-BA-e-1130

81 13.4 Instant help In case of an error in the program process, briefly turn off the balance and disconnect from power supply. The weighing process must then be restarted from the beginning. Fault Possible cause The displayed weight does not glow. The balance is not switched on. The mains supply connection has been interrupted (mains cable not plugged in/faulty). Power supply interrupted. The displayed weight is permanently changing Draught/air movement Glass doors not closed Table/floor vibrations Weighing pan has contact with other objects. Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) The weighing result is obviously incorrect The display of the balance is not at zero Adjustment is no longer correct. The balance is on an uneven surface. Great fluctuations in temperature. Warm-up time was ignored. Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) Should other error messages occur, switch balance off and then on again. If the error message remains inform manufacturer. ALT_B-PLT_A-PLT_F-BA-e

82 14 Declaration of conformity EC-Konformitätserklärung EC- Déclaration de conformité EC-Dichiarazione di conformità EC- Declaração de conformidade EC-Deklaracja zgodności D Konformitätserklärung EN Declaration of conformity CZ Prohlášení o shode E Declaración de conformidad F Déclaration de conformité I Dichiarazione di conformitá NL Conformiteitverklaring P Declaração de conformidade PL Deklaracja zgodności RUS Заявление о соответствии KERN & Sohn GmbH D Balingen- Frommern Postbox info@kern-sohn.de Declaration of conformity Phone: 0049-[0] Fax: 0049-[0] Internet: EC-Declaration of -Conformity EC-Declaración de Conformidad EC-Conformiteitverklaring EC- Prohlášení o shode EC-Заявление о соответствии Wir erklären hiermit, dass das Produkt, auf das sich diese Erklärung bezieht, mit den nachstehenden Normen übereinstimmt. We hereby declare that the product to which this declaration refers conforms to the following standards. Tímto prohlašujeme, že výrobek, kterého se toto prohlášení týká, je v souladu s níže uvedenými normami. Manifestamos en la presente que el producto al que se refiere esta declaración está de acuerdo con las normas siguientes Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la présente déclaration, est conforme aux normes citées ci-après. Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è conforme alle norme di seguito citate. Wij verklaren hiermede dat het product, waarop deze verklaring betrekking heeft, met de hierna vermelde normen overeenstemt. Declaramos por meio da presente que o produto no qual se refere esta declaração, corresponde às normas seguintes. Niniejszym oświadczamy, że produkt, którego niniejsze oświadczenie dotyczy, jest zgodny z poniższymi normami. Мы заявляем, что продукт, к которому относится данная декларация, соответствует перечисленным ниже нормам. Electronic Balance: KERN ALT_B, PLT_A, PLT_F EU Directive Standards 2004/108/EC EN (2006) EN (2006) EN (1995) + A1 (2001) + A2 (2005) 2006/95/EC EN (2001) 2005/32/EC EUP Date: Signature: KERN & Sohn GmbH Management KERN & Sohn GmbH, Ziegelei 1, D Balingen, Tel. +49-[0]7433/9933-0,Fax +49-[0]7433/ ALT_B-PLT_A-PLT_F-BA-e-1130

Operating instructions Analytical and precision balances

Operating instructions Analytical and precision balances KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Analytical and precision balances

More information

Operating instructions Analytical and precision balances

Operating instructions Analytical and precision balances KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Analytical and precision balances

More information

Instruction Manual Pocket scale

Instruction Manual Pocket scale KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Instruction Manual Pocket scale KERN TAB Version 1.1

More information

Operating instructions Analytical balance

Operating instructions Analytical balance KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kernsohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Analytical balance KERN ADB Type

More information

KERN EMS Version /2012 GB

KERN EMS Version /2012 GB Instruction Manual School balance KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-mail:info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com KERN EMS Version 1.3

More information

Operating instructions Precision balances

Operating instructions Precision balances KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Precision balances KERN EMB-S

More information

Operating manual Pallet truck scale

Operating manual Pallet truck scale Operating manual Pallet truck scale Jednoduchý paletový vozík s váhou KERN VHE-A(SK) KERN & Sohn GmbH Ziegelei 1 Phone: +49-[0]7433-9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@kern-sohn.com

More information

Operating manual Counting balances

Operating manual Counting balances KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating manual Counting balances KERN CXB Version

More information

Operating manual Counting balances

Operating manual Counting balances KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating manual Counting balances KERN CXB Version

More information

Operating manual Pallet scale

Operating manual Pallet scale KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating manual Pallet scale KERN UIB Version 1.0

More information

Operating Instructions Hanging Balance

Operating Instructions Hanging Balance KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating Instructions Hanging Balance KERN CH Version

More information

KERN PCD Version /2012 GB

KERN PCD Version /2012 GB KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-mail:info@kern-sohn.com Operating instructions Precision balance Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com KERN PCD

More information

Operating Manual Compact balance

Operating Manual Compact balance KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating Manual Compact balance KERN FKB_A Version

More information

Operating manual Precision balances

Operating manual Precision balances Operating manual Precision balances KERN EWJ Version 1.5 09/2016 GB KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet:

More information

Operating Manual Precision balance

Operating Manual Precision balance Operating Manual Precision balance KERN PFB Type PFB_NM Version 3.0 09/2016 GB KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-mail: info@kern-sohn.com Tel.: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149

More information

MEDIZINTECHNIK FÜR TIERÄRZTE

MEDIZINTECHNIK FÜR TIERÄRZTE GB Tabel of contents: Operation Instructions Electronic Platfoorm Balances MEDIZINTECHNIK FÜR TIERÄRZTE 1 Technical data 17 2 Fundamental information (general) 18 2.1 Intended use 18 2.2 Inappropriate

More information

Instruction Manual Counting balance

Instruction Manual Counting balance KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone +49-[0]7433-9933-0 Fax +49-[0]7433-9933-149 Internet: www.kern-sohn.com Instruction Manual Counting balance KERN CPB-N / CPB-DM

More information

HX-Series. HX-502 (500g x 0.01g) HX-3001 (3000g x 0.1g. Copyright 2014 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

HX-Series. HX-502 (500g x 0.01g) HX-3001 (3000g x 0.1g. Copyright 2014 American Weigh Scales, Inc. All rights reserved. Rev. 1.0 HX-Series HX-502 (500g x 0.01g) HX-3001 (3000g x 0.1g Copyright 2014 American Weigh Scales, Inc. All rights reserved. Rev. 1.0 Table of Contents Parts and Setup...1 Safety... 1 Service... 1 Unpacking...

More information

Operating manual Analysis and precision balances

Operating manual Analysis and precision balances KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating manual Analysis and precision balances

More information

PORTION CONTROL SCALE

PORTION CONTROL SCALE PORTION CONTROL SCALE 22 pounds/352 ounces/10 kilograms by grams, ounces, troy ounces, pounds, Hong Kong tael, Taiwan tael, grains, pennyweights, mommes, tolas, carats and free factor units 1 Specification

More information

KERN HDB-N Version /2016 GB

KERN HDB-N Version /2016 GB KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Operating manual Electronic Suspended balance Logbook Regular maintenance and care KERN HDB-N Version 2.4 06/2016 GB Phone: +49-[0]7433-9933-0

More information

Operating instructions Analytical balance

Operating instructions Analytical balance KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Operating instructions Analytical balance KERN AEJ_N/AES_N Version 2.1 03/2013 GB Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149

More information

Operating instructions Pallet truck scales

Operating instructions Pallet truck scales KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Pallet truck scales KERN VFS

More information

KERN HFT Version /2013 GB

KERN HFT Version /2013 GB KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating manual Electronic Crane Scales Logbook

More information

Operating instructions Precision balances

Operating instructions Precision balances KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Operating instructions Precision balances KERN PNJ / PNS Version 1.3 2017-11 GB Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149

More information

Instruction Manual Counting balance

Instruction Manual Counting balance KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone +49-[0]7433-9933-0 Fax +49-[0]7433-9933-149 Internet: www.kern-sohn.com Instruction Manual Counting balance KERN CPB-N / CPB-DM

More information

KERN KFB/KFN-TM Version /2010 GB

KERN KFB/KFN-TM Version /2010 GB KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating and Installation Instructions Display devices

More information

Operating and Installation Instructions Display Unit

Operating and Installation Instructions Display Unit KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating and Installation Instructions Display Unit

More information

Operating Manual. Professional Weighing Equipment. TB Series intelligent weighing machine. Touch Color Screen HIGH RESOLUTION BALANCE

Operating Manual. Professional Weighing Equipment. TB Series intelligent weighing machine. Touch Color Screen HIGH RESOLUTION BALANCE Professional Weighing Equipment Operating Manual TB Series intelligent weighing machine Touch Color Screen HIGH RESOLUTION BALANCE 1 Introduction What you should know about these Operating Instructions:

More information

EC Series Toploading Balances

EC Series Toploading Balances EC Series Toploading Balances Digital Balance Operator s Manual Rev 1.01 June 2006 Software 2.11 Page: 1 CONTENTS INTRODUCTION... 3 SPECIFICATIONS... 4 TECHNICAL SPECIFICATIONS... 4 COMMON SPECIFICATIONS...

More information

WeighSouth. WBT Toploader Balance

WeighSouth. WBT Toploader Balance WeighSouth WBT Toploader Balance Part List Balance...1 pc. Weighing Pan...1 pc. Draft Shield (Model WBT-100 only)...1 pc. Calibration Weight... WBT-100, WBT-602 AC Adapter...1 pc. Instruction Manual...1

More information

Operating instructions/ Návod na obsluhu Medical chair scales/zdravotnícke kreslové váhy Medical personal scales/zdravotnícke osobné váhy

Operating instructions/ Návod na obsluhu Medical chair scales/zdravotnícke kreslové váhy Medical personal scales/zdravotnícke osobné váhy KERN & Sohn GmbH Ziegelei 1 Phone: +49-[0]7433-9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 email: info@kern-sohn.com Internet: www.kern-sohn.com Operating instructions/ Návod na obsluhu Medical chair

More information

KERN KFS-TM Version GB

KERN KFS-TM Version GB KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating and Installation Instructions Display Unit

More information

CONTENTS Cautions before using 1-2. Specification and characteristics of products

CONTENTS Cautions before using 1-2. Specification and characteristics of products CONTENTS Ⅰ. Preparation before using 1-1. Cautions before using 1-2. Specification and characteristics of products Ⅱ. Introduction and installation of products 2-1. Assembly specification of scale pan

More information

User Manual. XK315A1 water proof series Weighing Indicators. Applications: Electronic platform scale, weighing scale, etc.

User Manual. XK315A1 water proof series Weighing Indicators. Applications: Electronic platform scale, weighing scale, etc. User Manual XK315A1 water proof series Weighing Indicators Applications: Electronic platform scale, weighing scale, etc. 1 Introductions 1.1 Safety precautions WARNING! Don t use XK315A1 series indicators

More information

BC Series Compact Counting Scale INSTRUCTION MANUAL

BC Series Compact Counting Scale INSTRUCTION MANUAL Compact Counting Scale INSTRUCTION MANUAL Ohaus Corporation, 19A Chapin Road, P.O. Box 2033, Pine Brook, NJ 07058, USA Declaration of Conformity We, Ohaus Corporation, declare under our sole responsibility

More information

Operator Manual. OHAUS Aviator 7000

Operator Manual. OHAUS Aviator 7000 Operator Manual OHAUS Aviator 7000 2 OHAUS Operator Manual Aviator 7000 Order number 72246392 Contents 1 Your new retail scale 5 1.1 Most important functions 5 1.2 Device overview 5 1.3 Safety instructions

More information

INSTALLATION uline.com UNPACKING ASSEMBLY LEVELING H-1096, H-1097 H-1098, H-1099 DELUXE COUNTING SCALE

INSTALLATION uline.com UNPACKING ASSEMBLY LEVELING H-1096, H-1097 H-1098, H-1099 DELUXE COUNTING SCALE π H-1096, H-1097 H-1098, H-1099 DELUXE COUNTING SCALE 1-800-295-5510 uline.com UNPACKING 1. Unpack and verify the following components have been included: Scale unit Instruction manual Weighing pan Power

More information

VWR B-Series Balances Operation Manual

VWR B-Series Balances Operation Manual VWR B-Series Balances Operation Manual TABLE OF CONTENTS SAFETY PRECAUTIONS. 1 GETTING STARTED..... 1 INSTALLATION & SET-UP.... 2 POWER CONNECTION.... 3 ANTI-THEFT DEVICE.... 3 LEVELING.... 3 CALIBRATION.....

More information

Contents

Contents Fixing the Weighing Pan Protection Device Disassembly Steps Contents ---------------------------------------------------------------------- 1 ----------------------------------------------------------------------

More information

MiniCD. User Manual. American Weigh Scales. MCD-100 (100 x 0.01g MCD-500 (500 x 0.1g)

MiniCD. User Manual. American Weigh Scales. MCD-100 (100 x 0.01g MCD-500 (500 x 0.1g) American Weigh Scales MiniCD User Manual MCD-100 (100 x 0.01g MCD-500 (500 x 0.1g) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2.0 MiniCD User Manual Thank you for purchasing the

More information

Contents

Contents Fixing the Weighing Pan Protection Device Disassembly Steps Contents ---------------------------------------------------------------------- 1 ----------------------------------------------------------------------

More information

Operating instructions. METTLER TOLEDO GoldPac-M SET PRICE ID NR DATE TIME C CODE CE. dwt PRINT

Operating instructions. METTLER TOLEDO GoldPac-M SET PRICE ID NR DATE TIME C CODE CE. dwt PRINT Operating instructions METTLER TOLEDO GoldPac-M g ID NR DATE TIME C ct CODE CE dwt PRINT PRICE CLEAR SAVE METTLER TOLEDO GoldPac-M METTLER TOLEDO GoldPac-M permits calculations with weight vallues and

More information

High Precision Balances. Operation Manual

High Precision Balances. Operation Manual High Precision Balances Operation Manual BN / CN-en, V5.1-2011 TABLE OF CONTENTS I. Overview ---------------------------------------- 1 II. Specifications and performance --------------- 1 III. Preparations

More information

Explorer. Analytical and Precision Balances. Features Include:

Explorer. Analytical and Precision Balances. Features Include: Explorer Analytical and Precision Balances Completely re-imagined from the ground up, the OHAUS Explorer rises to a whole new level a product so extraordinary, it s like nothing you ve seen before! The

More information

Inscale Measurement Technology Ltd Tel: Fax:

Inscale Measurement Technology Ltd Tel: Fax: TCC SERIES Inscale Measurement Technology Ltd 7 Heron Close, St. Leonards-on-Sea. East Sussex TN38 8DX United Kingdom Tel: +44(0)1424 200722 Fax: +44(0)1424 443976 Email: sales@inscale-scales.co.uk Http:www.inscale-scales.co.uk

More information

Operating Manual. Professional Weighing Equipment SCT SERIES Small Counting Scales. SCT 600g SCT 1200g

Operating Manual. Professional Weighing Equipment SCT SERIES Small Counting Scales. SCT 600g SCT 1200g Professional Weighing Equipment SCT SERIES Small Counting Scales SMALL COUNTING SCALE WITH CHECK-WEIGHING FUNCTION Operating Manual SCT 600g SCT 1200g 1 Declaration of Conformity Declaration of conformity

More information

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010)

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010) Adam Equipment LBH SERIES (P.N. 700660113, Revision B2, January 2010) Adam Equipment Company 2010 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed

More information

CONTENTS. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1

CONTENTS. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1 CONTENTS 1. Introduction... 1 2. Precautions... 1 3. Before Using the Product 3-1 Unpacking and Checking. 1 3-2 Installing Components.... 1 3-3 Leveling the Scale.... 1 4. Product Introduction 4-1 Specifications

More information

Professional Weighing Equipment. K-Series Scales. Operation Manual KHR 6000 KHR 123 KHR 502 KHR 3001

Professional Weighing Equipment. K-Series Scales. Operation Manual KHR 6000 KHR 123 KHR 502 KHR 3001 Professional Weighing Equipment K-Series Scales Operation Manual KHR 6000 KHR 123 KHR 502 KHR 3001 Table of Contents Section Page Declaration of Conformity 3 Customer Service 4 Introduction 5 Safety 6

More information

User s Guide. Weighing Indicator WIDRA - HF L / HF S 2000/02/11 21:21:58. No. TARE NET GROSS TOTAL

User s Guide. Weighing Indicator WIDRA - HF L / HF S 2000/02/11 21:21:58. No. TARE NET GROSS TOTAL - 9-2000/02/11 21:21:58 No. TARE NET GROSS TOTAL ----------------------------------------------- 001 0.000U1 0.034U1 0.034U1 0.034U1 DATE 2000/02/11 TIME 21:26:56 NO. 001 TARE 0.000kg NET 0.076kg GROSS

More information

User Manual. Precision Balances XSR models

User Manual. Precision Balances XSR models User Manual XSR models Overview balances with S weighing platform 4 3 5 2 3 1 6 7 2 8 8 10 9 10 9 Legend balances with S weighing platform 1 MagicCube Draft Shield 6 MagicCube Draft Shield side door 2

More information

BA110 Electronic Balance 5000g x 1g. Impact Test Equipment Ltd & User Guide. User Guide

BA110 Electronic Balance 5000g x 1g. Impact Test Equipment Ltd   &   User Guide. User Guide BA110 Electronic Balance 5000g x 1g Impact Test Equipment Ltd www.impact-test.co.uk & www.impact-test.com User Guide User Guide Impact Test Equipment Ltd. Building 21 Stevenston Ind. Est. Stevenston Ayrshire

More information

Operating Instructions Personal weighing scale, Stand on scale, Wheelchair scale, Chair scale

Operating Instructions Personal weighing scale, Stand on scale, Wheelchair scale, Chair scale KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-mail: info@kern-sohn.com Tel.: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Website: www.kern-sohn.com Operating Instructions Personal weighing scale, Stand

More information

User Manual TD-Series Balance Series

User Manual TD-Series Balance Series User Manual TD-Series Balance Series 01-16-17 REV03 1 2 Contents 1. GENERAL INFORMATION... 6 1.1 INTENDED USE... 6 1.2 PRECAUTIONS... 6 1.3 SUPERVISION OVER METROLOGICAL PARAMETERS... 6 1.4 WARRANTY CONDITIONS...

More information

MANUAL JCE-SERIES CHAPTER

MANUAL JCE-SERIES CHAPTER MANUAL JCE-SERIES CHAPTER 1 INTRODUCTION ------------------------------ 1 2 ASSEMBLY ------------------------------ 2 3 INSTALLATION ------------------------------ 2 4 PRECAUTION ------------------------------

More information

User Manual Cole-Parmer Symmetry Balances Analytical Balances: TA.C and TA Series Precision Toploading Balances: TT.

User Manual Cole-Parmer Symmetry Balances Analytical Balances: TA.C and TA Series Precision Toploading Balances: TT. User Manual Cole-Parmer Symmetry Balances Analytical Balances: TA.C and TA Series Precision Toploading Balances: TT.C and TT Series 1 01-26-18 REV03 2 Contents 1. GENERAL INFORMATION... 7 1.1 INTENDED

More information

Models TJ30K TJ15K TJ6K TJ3K. Resolution Ratio 1g 0.5g 0.2g 0.1g Calibration graduation 10d 10d 10d 10d

Models TJ30K TJ15K TJ6K TJ3K. Resolution Ratio 1g 0.5g 0.2g 0.1g Calibration graduation 10d 10d 10d 10d Operating Instruction Manual of TJ Series Electronic counting balance ( for following models: TJ3K,TJ6K,TJ15K,TJ30K,TJ3KA,TJ6KA,TJ15KA, TJ30KA) 1. Overview TJ series electronic counting weighing apparatus

More information

KERN HDB Type HDB-N Type HDB-XL Version GB

KERN HDB Type HDB-N Type HDB-XL Version GB KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Operating manual Electronic Suspended balance Logbook Regular maintenance and care KERN HDB Type HDB-N Type HDB-XL Version 3.0 2017-04

More information

User Manual Cole-Parmer Symmetry Balances Analytical Balances: LA and LA.C Series Precision Toploading Balances: LT and LT.

User Manual Cole-Parmer Symmetry Balances Analytical Balances: LA and LA.C Series Precision Toploading Balances: LT and LT. User Manual Cole-Parmer Symmetry Balances Analytical Balances: LA and LA.C Series Precision Toploading Balances: LT and LT.C Series 11-06-17 REV03 1. GENERAL INFORMATION... 6 1.1 INTENDED USE... 6 1.2

More information

KERN KFB / KFN-TAM Version /2017 GB

KERN KFB / KFN-TAM Version /2017 GB KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating and Installation Instructions Display devices

More information

Instruction Manual: AGZN and AGCN Analytical Balances

Instruction Manual: AGZN and AGCN Analytical Balances Instruction Manual: AGZN and AGCN Analytical Balances Table of Contents Chapter 1: Cautionary Notes and Warnings... 1 Chapter 2: Specifications... 3 Chapter 3: Parts Description... 4 Chapter 4: Keys, Display

More information

Adam Equipment LBC SERIES. (P.N , RevisionB1, January 2010)

Adam Equipment LBC SERIES. (P.N , RevisionB1, January 2010) Adam Equipment LBC SERIES (P.N. 700660114, RevisionB1, January 2010) Adam Equipment Company 2010 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed

More information

Use and Maintenance Manual

Use and Maintenance Manual Compact Bench Piececounter for Internal Use C 100 Use and Maintenance Manual Code 81320222 DECLARATION OF CONFORMITY SOCIETA COOPERATIVA BILANCIAI Via S.Ferrari,16 41011 Campogalliano (MO) ITALIA We declare

More information

User Manual Cole-Parmer Symmetry Balances Analytical Balances: LA, LA.C, and LA.N Series Precision Toploading Balances: LT, LT.C, and LT.

User Manual Cole-Parmer Symmetry Balances Analytical Balances: LA, LA.C, and LA.N Series Precision Toploading Balances: LT, LT.C, and LT. User Manual Cole-Parmer Symmetry Balances Analytical Balances: LA, LA.C, and LA.N Series Precision Toploading Balances: LT, LT.C, and LT.N Series 05-01-18 REV04 1 2 1. GENERAL INFORMATION... 6 1.1 INTENDED

More information

Instruction Manual: AD Series

Instruction Manual: AD Series Instruction Manu ual: AD Series Table of Contents Chapter 1: Cautionary Notes and Warnings... 1 Chapter 2: Specifications... 3 Chapter 3: Parts Description... 4 Chapter 4: Keys, Display Indicators and

More information

LC-VS 60 Operation Manual

LC-VS 60 Operation Manual LC-VS 60 Operation Manual Section Table of Contents Page Declaration of Conformity 3 Customer Service 4 Introduction 4 Safety 5 Features 6 Application & Conformity 6 Getting Started 7 Delivery 7 Application

More information

Adam Equipment LBC SERIES. (P.N , RevC, August 2011)

Adam Equipment LBC SERIES. (P.N , RevC, August 2011) Adam Equipment LBC SERIES (P.N. 700660114, RevC, August 2011) Adam Equipment Company 2011 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power

More information

Operating instructions. METTLER TOLEDO B balance line AB PB SB

Operating instructions. METTLER TOLEDO B balance line AB PB SB Operating instructions METTLER TOLEDO B balance line AB PB SB Short-form operating instructions Press key briefly Adjusting (calibration) Piece counting* Dynamic weighing* Press and hold key until the

More information

CN Series P.N , Software rev. T 8, Revision A1- July 2014

CN Series P.N , Software rev. T 8, Revision A1- July 2014 Adam Equipment CN Series P.N. 7.00.6.6.0199, Software rev. T 8, Revision A1- July 2014 Adam Equipment 2014 Adam Equipment 2014 CONTENTS 1.0 INTRODUCTION... 2 2.0 SPECIFICATIONS... 3 2.1 DISPLAY AND KEYPAD...

More information

Weighing Indicator YH-T3. User Manual

Weighing Indicator YH-T3. User Manual Weighing Indicator YH-T3 User Manual Content CHAPTER 1 MAIN SPECIFICATION......-2- CHAPTER 2 INSTALLATION......- 3-2.1 FRONT AND BACK VIEW OF INDICATOR... - 3-2.2 CONNECTING LOAD CELL TO INDICATOR...-

More information

Operating instructions. METTLER TOLEDO MultiRange Application software IND690-FormXP.

Operating instructions. METTLER TOLEDO MultiRange Application software IND690-FormXP. Operating instructions METTLER TOLEDO MultiRange Application software IND690-FormXP www.mt.com/support Congratulations on choosing the quality and precision of METTLER TOLEDO. Proper use according to these

More information

Table of Contents. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1

Table of Contents. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1 Table of Contents 1. Introduction.... 1 2. Precautions. 1 3. Before Using the Product 3-1 Unpacking and Checking. 1 3-2 Installing Components..... 1 3-3 Leveling the Scale..... 1 4. Product Introduction

More information

Moisture analyser KERN MLS-A. Moisture analyser with 49 memories for individual drying processes. Features

Moisture analyser KERN MLS-A. Moisture analyser with 49 memories for individual drying processes. Features Moisture analyser KERN MLS-A 04 Moisture analyser with 49 memories for individual drying processes KERN MLS 65-3A MLS 150-2A Readout [d] 0,001 g / 0,01 % 0,01 g / 0,05 % Weighing range [Max] 65 g 150 g

More information

EC Type-Approval Certificate

EC Type-Approval Certificate EC Type-Approval Certificate No. DK 0199.365 Revision 3 MBC / MPE / MPD / MPC / MCC / MWA / MTA NON-AUTOMATIC WEIGHING INSTRUMENT Issued by DELTA Danish Electronics, Light & Acoustics EU - Notified Body

More information

Operation Manual. Professional Weighing Equipment. MRB Series Mid Resolution Balances. MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g

Operation Manual. Professional Weighing Equipment. MRB Series Mid Resolution Balances. MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g Professional Weighing Equipment MRB Series Mid Resolution Balances Compact Scales MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g Operation Manual Section Table of Contents Page Declaration of Conformity

More information

BALANCES APP/2C SERIES

BALANCES APP/2C SERIES User manual no.: LMI-53-05/11/12/A BALANCES APP/2C SERIES MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS RADWAG 26 600 Radom, Bracka 28, POLAND phone +48 48 38 48 800, fax. +48 48 385 00 10 e-mail: export@radwag.com

More information

D Sep ATX324 ATX224 ATX124 ATX84 ATY324 ATY224 ATY124 ATY64

D Sep ATX324 ATX224 ATX124 ATX84 ATY324 ATY224 ATY124 ATY64 321-78001D Sep. 2016 ATX324 ATX224 ATX124 ATX84 ATY324 ATY224 ATY124 ATY64 Requests Provide this manual to the next user in the event that the instrument is transferred. To ensure safe operation, contact

More information

BEFORE USING THE COUNTING SCALE

BEFORE USING THE COUNTING SCALE π H-1114, H-1115 H-1116, H-1117 INDUSTRIAL COUNTING SCALES 1-800-295-5510 uline.com WEIGH T UNIT WEIGH T lb/1000 Pc s u 1-800-295-5510 7 8 9 4 5 6 1 2 3 QTY UNIT PST UNIT PST ZERO TOTAL 0. CE TARE TOTAL

More information

Operating manual Digital refractometer

Operating manual Digital refractometer KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen, Germany E-mail: info@kern-sohn.com Operating manual Digital refractometer Tel: +49-[0]7433-9933-0 Fax: +49 (0)7433-9933-149 Internet: www.kern-sohn.com KERN

More information

Operating instructions and installation information. METTLER TOLEDO MultiRange ID7-Form-XP application software

Operating instructions and installation information. METTLER TOLEDO MultiRange ID7-Form-XP application software T Operating instructions and installation information METTLER TOLEDO MultiRange ID7-Form-XP application software ID7-Form-XP Contents Contents Page 1 Introduction and assembly... 2 1.1 Introduction...

More information

Instruction number PTI-16-03/09/06/A

Instruction number PTI-16-03/09/06/A Instruction number PTI-16-03/09/06/A MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS RADWAG 26 600 Radom Bracka 28 Street Phone +48 48 38 48 800, phone/fax. +48 48 385 00 10 Selling department +48 48 366

More information

Contents Balance-pan fixing

Contents Balance-pan fixing Contents Balance-pan fixing --------------------------------------------------- 1 Protection device --------------------------------------------------- 1 Installation mode ---------------------------------------------------

More information

Operating instructions School balance

Operating instructions School balance KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions School balance KERN 442 Version

More information

Operating Instructions. Precision Balances XSR models

Operating Instructions. Precision Balances XSR models Operating Instructions XSR models Table of Contents 1 Introduction 5 1.1 Conventions and symbols used in these operating instructions... 6 2 Safety Information 7 2.1 Definition of signal warnings and

More information

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31) Best Selection for Your Business Electronic Pricing Scale User s Manual (Model: TP-31) CATALOG 1. Foreword... 2 1.1. Introductions... 2 1.2. Main functions and features... 2 1.3. Specification... 2 1.4.

More information

MS 3801 USER MANUAL. Manufactured by: Charder Electronic Co., Ltd. No.103, Guozhong Rd., Dali Dist., Taichung City 412, Taiwan (R.O.C.

MS 3801 USER MANUAL. Manufactured by: Charder Electronic Co., Ltd. No.103, Guozhong Rd., Dali Dist., Taichung City 412, Taiwan (R.O.C. Manufactured by: Charder Electronic Co., Ltd. No.103, Guozhong Rd., Dali Dist., Taichung City 412, Taiwan (R.O.C.) FDA no.: D051883 / 3007074192 MS 3801 USER MANUAL IN-1111 [9073D] 08/2012 15 Please keep

More information

Operator Manual. brite Advanced Retail scale

Operator Manual. brite Advanced Retail scale Operator Manual brite Advanced Retail scale 2 METTLER TOLEDO Operator Manual brite Advanced Order number 30209977 Contents 1 Your new retail scale 5 1.1 Most important functions 5 1.2 Device overview 5

More information

PK-110. User Manual. American Weigh Scales. PK-110 (0-44lb x 0.05lb / lb x 0.1lb)

PK-110. User Manual. American Weigh Scales. PK-110 (0-44lb x 0.05lb / lb x 0.1lb) American Weigh Scales PK-110 User Manual PK-110 (0-44lb x 0.05lb / 44-110lb x 0.1lb) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 1.1 PK-110 Manual Thank you for purchasing the

More information

Operating Instructions

Operating Instructions Operating Instructions Excellence Balances XS Models Part 2 Terminal System settings Firmware Applications Weighing Statistics Formulation Piece Counting Percent Weighing Density Dynamic Weighing LabX

More information

WS 10 Weighing indicator USER MANUAL

WS 10 Weighing indicator USER MANUAL WS 10 Weighing indicator USER MANUAL Edition:10052001A Safety Instruction For safety operation follow the safety instructions. WARNING Setting, Calibration Inspection and Maintain of the indicator is prohibited

More information

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65 Professional Weighing Equipment MRW SERIES intelligent weighing scale WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65 WITH PIECE COUNTING FUNCTION Operation Manual Section Table of Contents Page

More information

Operating Instructions METTLER TOLEDO Excellence XS Precision Balances

Operating Instructions METTLER TOLEDO Excellence XS Precision Balances Operating Instructions METTLER TOLEDO Excellence XS Precision Balances www.mt.com/support Overview of your XS precision balance 6 5 7 10 11 8 6 6 4 3 2 1 10 3 3 11 11 6 1 Terminal (for details s. Section

More information

Manual. AGRETO Hydraulic Scale AGRETO electronics GmbH

Manual. AGRETO Hydraulic Scale AGRETO electronics GmbH Manual AGRETO Hydraulic Scale 22.04.2014 AGRETO electronics GmbH Content 1 Introduction... 3 2 Scope of Delivery... 3 3 Intended Use... 3 4 Security... 4 4.1 Safety Instructions for the Buyer... 4 4.2

More information

X2 Series Balances USER MANUAL. AS X2 Analytical Balances PS X2 Precision Balances APP X2 Precision Balances IMMU EN.

X2 Series Balances USER MANUAL. AS X2 Analytical Balances PS X2 Precision Balances APP X2 Precision Balances IMMU EN. X2 Series Balances AS X2 Analytical Balances PS X2 Precision Balances APP X2 Precision Balances USER MANUAL IMMU-16-14-02-16-EN www.radwag.com If you are reading this, it means that you are bound to achieve

More information

High Precision Balances

High Precision Balances CÔNG TY CỔ PHẦN CÂN ĐIỆN TỬ THỊNH PHÁT High Precision Balances Operation Manual KD- HBC-en, V5.0-2010 TABLE OF CONTENTS I. Overview ---------------------------------------- 1 II. Attentions ----------------------------------------

More information