FACILITY RESPONSE PLAN REVIEW CHECKLIST
|
|
- Tracy Carr
- 6 years ago
- Views:
Transcription
1 FACILITY RESPONSE PLAN REVIEW CHECKLIST Fixed / Mobile Facility Name: Facility ID: 1 st Reviewer: Date: 2 nd Reviewer: Date: Guidance for completing the Facility Response Plan Review Checklist for Fixed or Mobile Facilities. Coast Guard facility inspectors shall complete the checklist by verifying the contents within are in line with the requirements as per 33 CFR 154 (Note updates to removal equipment requirements/alternative technology per 74 FR 167 / 31 Aug 2009 / Pg ). Each inspected item contained in the checklist must be notated as one of the following: YES Item meets requirements of this checklist and referenced regulations. NO Item does not meet requirements of this checklist and referenced regulations or is missing altogether. Page # - Optional (Denotes Page or Section Number in Facility s Response Plan)
2 Purpose The purpose of a facility response plan is to enhance the preparedness of the owner/operator and facility personnel to respond to an actual or threatened discharge of oil. The key elements in effective preparedness are properly trained personnel, prearranged private response resources, and a plan for timely and efficient activation and employment of equipment and personnel. With this purpose in mind, comment on the plan s overall effectiveness, workability and organization for ease of use toward the goal of enhancing preparedness Applicability Verify MTR Facility is: Fixed Mobile Verify MTR Facility classification is: Substantial Harm Significant & Substantial Harm & 108 Alternatives / Exemptions Verify if there are any alternatives /exemptions granted for the MTR facility under this plan. (Note: If any have been granted, revisions must be reflected in the plan. Indicate here the type of and whether the required amendments have been made to the plan) General Response Plan Contents Y N Page # Comments (a) Verify the plan is written in English (b) Verify the response plan is divided into the sections listed and formatted in order specified or contains a cross-referenced index page. Plan must have a marker identifying each of the following below: (b)(1) (b)(2) (b)(2)(i) (b)(2)(ii) (b)(2)(iii) (b)(2)(iv) (b)(2)(v) (b)(3) (b)(3)(i) (b)(3)(ii) (b)(4) (b)(5) (b)(5)(i) (b)(5)(ii) (b)(5)(iii) (b)(5)(iv) (b)(5)(v) (b)(5)(vi) (b)(5)(vii) (c) Introduction and plan contents Emergency response action plan: Notification procedures Facility s spill mitigation procedures Facility s response activities Fish and wildlife and sensitive environments Disposal plan Training and Exercises: Training procedures Exercise procedures Plan review and update procedures Appendices: Facility-specific information List of contacts Equipment lists and records Communications plan Site-specific safety and health plan List of acronyms and definitions A geographic-specific appendix for each zone in which a mobile facility operates Verify required contents for each section and subsection of the plan are contained in ,.1040, and.1041, as appropriate 2
3 General Response Plan Contents (con t) Y N Page # Comments (d) Verify response plans submitted to COTP must contain at a minimum, all information required in , 1040, and 1041, as appropriate. Note: Plan may contain additional information required by outside agencies (e) Verify that for initial and subsequent submission, if plan does not follow format specified in paragraph (b) of this section, must be supplemented with a detailed cross reference section to identify the location of the applicable sections required by this subpart (f) Verify response plan information consistent with NCP (40 CFR 300) and ACP covering that area. Owners or operators shall ensure plans are IAW the ACP in effect 6 months prior to initial submission or annual plan review required under (a). Facility O/OP s are not required to, but may at their option, conform to an ACP which is less than 6 months old at the time of plan submission Significant & Substantial Harm Facilities (S&SH) (a) Verify the introduction and plan content includes: (a)(1) Facility s name, full street address (& mailing address-if different), telephone/fax numbers (a)(2) Facility s geographic location; such as river mile or location from a known landmark that would appear on a map or chart (a)(3) The name, address, and procedures for contacting the facility s owner or operator on a 24-hour basis (a)(4) (a)(5) (a)(6) A table of contents During the period that the submitted plan does not have to conform to the format contained in this subpart, a cross-index, if appropriate A record of change(s) (b) Verify the Emergency Response Action Plan content includes the following: (b)(1) Notification procedures: (b)(1)(i) Contains a prioritized list identifying persons including name, phone number (unless listed elsewhere), and role in plan who must be notified of a discharge or substantial threat of discharge of oil. This section must include: (b)(1)(i)(a) Facility response personnel, the spill management team, Oil Spill Removal Organizations (OSRO s), QI(s) /AQI(s); and (b)(1)(i)(b) Federal, State, or local agencies, as required (b)(1)(ii) Notification form similar to one shown in Fig. 1- Information on Discharge of Form must include notification of the NRC. It must also contain prominent statement that initial notification must not be delayed pending collection of all information 3
4 (b)(2) Facilities spill mitigation procedures: (b)(2)(i) Describe volume(s) and oil groups (persistent / nonpersistent) that would be involved in the: (b)(2)(i)(a) Average most probable discharge from the MTR facility (b)(2)(i)(b) Maximum most probable discharge from the MTR facility (b)(2)(i)(c) Worst Case Discharge from the MTR facility; and (b)(2)(i)(d) If applicable, worst case discharge from the non-mtr portion of facility (b)(2)(ii) Prioritized procedures for facility personnel by job title to mitigate or prevent a spill resulting from operational activities associated with internal or external facility transfers including procedures to shut down affected operations in event of: (b)(2)(ii)(a) Failure of manifold, mechanical loading arm, other transfer equipment on hoses as appropriate (b)(2)(ii)(b) Tank overfill (b)(2)(ii)(c) Tank failure (b)(2)(ii)(d) Piping rupture (b)(2)(ii)(e) Piping leak bother under pressure and not under pressure, if applicable (b)(2)(ii)(f) (b)(2)(ii)(g) (b)(2)(iii) (b)(3) (b)(3)(i) (b)(3)(ii) (b)(3)(iii) (b)(3)(iii)(a) (b)(3)(iii)(b) (b)(3)(iii)(c) (b)(3)(iii)(d) (b)(3)(iii)(e) (b)(3)(iii)(f) (b)(3)(iii)(g) (b)(3)(iii)(g) (b)(3)(iv) Explosion or fire Equipment failure (e.g. pumping system or relief valve failure, or failure of other equipment associated with internal or external transfers) List of equipment and responsibilities of facility personnel to mitigate an average most probable discharge Facilities response activities: Description of facility personnel s responsibilities to initiate and supervise a response pending arrival of QI or AQI Description of the responsibilities and authority of the QI and AQI as required in Identify personnel who will manage response actions and provide a description of duties for the following positions: Command and Control Public Information Safety Liaison with government agencies Spill Operations Planning Logistics support Finance This subsection of the plan must identify the oil spill removal organization (OSRO) and the spill management team (SMT) that are capable of providing the following resources: 4
5 (b)(3)(iv)(a) Equipment and supplies to meet the requirements of , or subparts H or I of this part, as appropriate (b)(3)(iv)(b) Trained personnel to operate equipment and staff the OSRO and SMT for seven days (b)(3)(v) This section must include job descriptions for each SMT member within the organizational structure described in paragraph (b)(3)(iii) of this section. These job descriptions include the responsibilities and duties of each SMT member in a response action. (b)(3)(vi) For facilities that handle, store, or transport group II through group IV petroleum oils, and that operate in waters where dispersant use is pre-authorized, this subsection of the plan must also separately list the resource providers and specific resources, including appropriately trained dispersant-application personnel. Must be available by contract or other approved means as described in (a). Must include the following: (b)(3)(vi)(a) Identification of each primary dispersant staging site to be used by each dispersant-application platform to meet the requirements of this subpart (b)(3)(vi)(b) Identification of platform type, resource-providing organization, location, and dispersant payload of reach dispersant-application platform identified. Location data must identify the distance between the platform s home base and the identified primary dispersant staging site for this section (b)(3)(vi)(c) For each unit of dispersant stockpile required to support the effective daily application capacity (EDAC) of each dispersant-application platform necessary to sustain each intended response tier of operation, identify the dispersant product resource provider, location, and volume. Location data must include the stockpile s distance to the primary staging sites where the stockpile would be loaded onto the corresponding platforms (b)(3)(vi)(d) If an OSRO has been evaluated by the USCG, and its capability is equal to or exceeds the response capability needed by the owner or operator, the section may identify only the OSRO, and not the information required in paragraphs (b)(3)(vi)(a) (C) of this section (b)(3)(vii) This subsection must separately list the resource providers and specific resources necessary to provide aerial oil tracking capabilities. The oil tracking resources to be listed must include the following: (b)(3)(vii)(a) Identification of the source provider; and (b)(3)(vii)(b) Type and location of aerial surveillance aircraft that are ensured available, through contract or other approved means, to meet the oil tracking requirements of (j) 5
6 (b)(3)(viii) For Mobile facilities that operate in more than one COTP zone, the plan must identify the OSRO and the SMT in the applicable geographic-specific appendix. The OSRO(s) and the SMT discussed in paragraph (b)(3)(iv) of this section must be included for each COTP zone in which the facility will handle, store, or transport oil in bulk (b)(4) (b)(4)(i) (b)(4)(ii) (b)(4)(ii)(a) (b)(4)(ii)(b) (b)(4)(ii)(c) (b)(4)(iii) (b)(5) (c) (c)(1) (c)(2) (d) (e) (e)(1) Fish and Wildlife and Sensitive Environments Identify areas of economic importance and environmental sensitivity, as identified in the ACP, which are potentially impacted by a WCD. For a worst case discharge, the plan must: List areas of economic and environmental sensitivity which may potentially be impacted by discharge of persistent, non-persistent, or non-petroleum oils Describe the specific planned response actions to protect identified areas Contain a map or chart (with legend) showing the locations of sensitive areas which may potentially be impacted. Must also depict response actions, which will be used to protect these areas For a WCD, this section must identify appropriate equipment and required personnel, available by contract or other approved means as described in , to protect fish and wildlife and sensitive environments which fall within the distances calculated using the methods outlined in this paragraph Disposal Plan - This subsection must describe any actions to be taken or procedures to be used to ensure that all recovered oil and oil contaminated debris produced as a result of any discharge are disposed according to Federal, state, or local requirements Training and Exercises - This section must be divided into the following two subsections: Training procedures Describes the training procedures and programs of the facility owner or operator to meet the requirements in Exercise procedures Describes the exercise program to be carried out by the facility owner or operator to meet the requirements of Plan review and update procedures This section must address the procedures to be followed by the facility owner or operator to meet the requirements of and the procedures to be followed for any post-discharge review of the plan to evaluate and validate its effectiveness Appendices This section of response plan must include the appendices described in this paragraph Facility specific information Must contain a description of the facility s principal characteristics: 6
7 (e)(1)(i) A physical description of the facility including a plan of the facility showing the mooring area, transfer locations, control stations, locations of safety equipment, and the location and capacity of all piping and storage tanks (e)(1)(ii) Identify the sizes, types, and number of vessels that the facility can transfer oil to or from simultaneously (e)(1)(iii) Identify the first valve(s) on facility piping separating the MTR portion from the non-mtr portion of the facility, if any. (e)(1)(iv) Information on the oil(s) and hazardous material handled, stored, or transported at the facility in bulk. A material safety data sheet (MSDS) meeting requirements of 29 CFR , 33 CFR (a)(5) or an equivalent will meet this requirement. This information can be maintained separately providing it is readily available and the appendix identifies its location. This information must include-- (e)(1)(iv)(a) Generic or chemical name (e)(1)(iv)(b) Description of the appearance and odor (e)(1)(iv)(c) Physical and chemical characteristics (e)(1)(iv)(d) Hazards involved in handling the oil(s) and hazardous materials (e)(1)(iv)(e) List of firefighting procedures and extinguishing agents (e)(1)(v) Make note of-- the appendix may contain any other information which the facility owner or operator determines to be pertinent to an oil spill response (e)(2) (e)(2)(i) (e)(2)(ii) (e)(2)(iii) (e)(3) (e)(3)(i) (e)(3)(ii)&(iii) List of contacts This appendix must include a list of 24-hour contacts for key personnel and organizations (unless listed elsewhere), the list must include: Primary and alternate(s) QI Contacts for OSROs retained under contract see paragraph (b)(3)(iv) Appropriate Federal, State, and local officials Equipment lists and records must include: List of equipment and facility personnel required to respond to an average most probable discharge. The location of equipment must also be included A detailed listing of all major equipment indentified in the plan which is available by contract or other means identified in See (e)(iii) for allowed exceptions. The list, if required shall include skimmers; booms; dispersant application, insitu burning, bioremediation equipment, and supplies; communications, firefighting and beach cleaning equipment; and heavy equipment 7
8 (e)(4) Communications plan Must describe the primary and alternate method of communication during discharges, including communications at the facility and at remote locations within the areas covered by the response plan (e)(5) Site-specific safety and health plan Must describe the safety and health plan to be implemented for any response locations(s). It must provide as much detailed information as is practicable in advance of an actual discharge. This appendix may reference another existing plan required under 29 CFR (e)(6) List of acronyms and definitions Must list all acronyms used in the response plan including any terms or acronyms used by Federal, State, or local governments and any operational terms commonly used at the facility, and including all definitions that are critical to understanding the response plan Substantial Harm Facility (SH) (a) Verify owner or operator of the facility, under ; submitted response plan meets the requirements of , except as modified by this section (b) Note that the facility s response activities section of the response plan need not list the facility or corporate organizational structure that will be used to manage the response, as required by (b)(3)(iii) (c) (d) Verify owner or operator of the facility ensure the availability of response resources required to be identified in (b)(3)(iv) by contract or other approved means described in Verify owner or operator has at least 200 feet of containment boom, and the means of deploying and anchoring the boom, available at the spill site within 1 hour of the detection of a spill to respond to the AMPD in lieu of the quantity of containment boom specified in (c)(1) unless COTP specifies otherwise. In addition, must be adequate sorbent material for initial response to an AMPD. --If Fixed facility; boom and sorbent material must be located at the facility. --If Mobile facility; boom and sorbent material must be available locally and be at the site of the discharge within 1 hour of its discovery. 8
9 Mobile MTR Facilities Y N Page # Comments (a) (a)(1) (a)(2) (a)(3) (b) Verify the following information is contained within the response plan and Mobile facility is required to carry when performing transfer operations: Description of response activities for a discharge which may occur during transfer operations. May be in narrative form or list of procedures to be followed in event of discharge Identity of response resources to respond to a discharge from the mobile MTR Facility List of the appropriate person and agencies (includes phone numbers) to be contacted, to include NRC Verify plan states owner or operator of the mobile facility must retain the information in this paragraph at the principal place of business Discrepancies: Cite(s): Comments: 9
Clean Water 2020 Program
Clean Water 2020 Program WWTP OPERATIONS PROGRAM Updated December 2015 Table of Contents WWTP Operations Program 2015 List of Tables... 2 Program Summary and Intent... 3 Operations Plan... 3 Process Control
More informationOverview of EPA s Facility Response Plan Rule
Presentation to DLA Worldwide Energy Conference April 2017 Overview of EPA s Facility Response Plan Rule J. Troy Swackhammer U.S. EPA, Office of Emergency Management Presentation Overview I. Introduction
More informationA COMPARISON OF WEST COAST CONTINGENCY PLANNING REQUIREMENTS FOR OIL HANDLING FACILITIES AND VESSELS
PACIFIC STATES BRITISH COLUMBIA OIL SPILL TASK FORCE A COMPARISON OF WEST COAST CONTINGENCY PLANNING REQUIREMENTS FOR OIL HANDLING FACILITIES AND VESSELS ALASKA BRITISH COLUMBIA CALIFORNIA OREGON WASHINGTON
More informationHazards. Hazards. Hazards. Effects on the Body. GA Tech Electrical Safety Presentation
Hazards The direct result can be electrocution. SHOCK. Electric shock occurs when the human body becomes part of the path through which current flows. The indirect result can be injury resulting from a
More informationTemplate Document for the Interim Final Rule 33 CFR
Template Document for the Interim Final Rule 33 CFR 105.405 POC: Facility Security Officer Facility Name and Address Business Phone 24 Hour Contact Number This cover page is a recommendation to ease contact
More informationMARINE SAFETY INFORMATION BULLETIN
UNITED STATES COAST GUARD SECTOR NEW ORLEANS MARINE SAFETY INFORMATION BULLETIN Volume XVII, Issue 018 DATE: 0000 TIME: 01JUN17 Hurricane Season 2017: Regulated Waterfront Facilities A. Severe Weather/Hurricane
More informationStandard for demolition and renovation.
61.145 - Standard for demolition and renovation. (a) Applicability. To determine which requirements of paragraphs (a), (b), and (c) of this section apply to the owner or operator of a demolition or renovation
More informationBringing RP 1174 Onshore Hazardous Liquid Pipeline Emergency Preparedness and Response to Life in Your Organization
Bringing RP 1174 Onshore Hazardous Liquid Pipeline Emergency Preparedness and Response to Life in Your Organization Recent PHMSA Rules Created Pipeline & Hazardous Materials Safety Administration (PHMSA)
More informationAPPENDIX D HAZARD EVALUATIONS / WORST CASE DISCHARGE CALCULATIONS
APPENDIX D HAZARD EVALUATIONS / WORST CASE DISCHARGE CALCULATIONS D.1 Hazard Identification 2 D.1.1 Tank Leak, Rupture or Overfill 2 D.1.2 Tank Truck Leak or Overfill 2 D.1.3 Piping or Valve Rupture or
More informationSpill Response Procedures
Spill Response Procedures [your municipality] Purpose: The purpose of this Standard Operating Procedure (SOP) is to provide guidance for the proper response and corrective actions to be followed in the
More informationa. Each land-based portable or mobile element of a marine vapor control system that connects to or from a vessel.
Commandant United States Coast Guard 2703 Martin Luther King Jr. Ave,S.E. STOP 7509 Washington, DC 20593-7509 Staff Symbol: CG-ENG Phone: (202) 372-1412 Fax: (202) 372-8380 From: To: J. W. Mauger, CAPT
More informationAPPENDIX H RULE 98 REQUIREMENTS CHART
APPENDIX H RULE 98 REQUIREMENTS CHART Hazardous Oil and Gas Waste Generator Classification Decision Tree Railroad Commission of Texas Does the waste meet the definition of oil and gas waste (excludes
More informationDECLARATION OF INSPECTION
DOI DECLARATION OF INSPECTION CHECKLIST: (EXAMPLE: The Following Document is an example of a Declaration of Inspection. Other forms such as ISGOTT (International Oil Tanker and Terminal Safety Guide)-Type
More informationNational Contingency Plan Requirements for Area Contingency Plans. Fish and Wildlife and Sensitive Environments Plan Annexes.
National Contingency Plan Requirements for Area Contingency Plans Fish and Wildlife and Sensitive Environments Plan Annexes May 2014 VI Important: The National Contingency Plan (40 CFR Parts 9 and 300)
More informationSpill Prevention, Control and Countermeasures (SPCC) 40 CFR 112. For Bulk Facilities
Spill Prevention, Control and Countermeasures (SPCC) 40 CFR 112 For Bulk Facilities Do you have an oil? The list of Petroleum and Non-petroleum oils subject to the Clean Water Act requirements can be found
More informationEPA REGION 2 UPDATE. Presenter: Francesco Maimone Physical Scientist Date: October 10, 2017 For: 5 th NY Storage Tank Conference
EPA REGION 2 UPDATE Presenter: Francesco Maimone Physical Scientist Date: October 10, 2017 For: 5 th NY Storage Tank Conference \ Environmental Protection Agency THIS PRESENTATION WILL COVER SPCC & FRP
More informationPre-Shale (2005) Crude Oil Supply 3,4 : Production and Imports Focused on Coasts
PREVENTION Our priority is prevention. We take extensive precautions to prevent spills from ever occurring. Proactive inspections and preventive maintenance 24/7 monitoring of assets Rapid shutdown capabilities
More informationCHAPTER 1: ENVIRONMENTAL AND EMERGENCY RESPONSE PLANNING
This chapter summarizes: The importance of spill prevention Emergency Response Plans applicable to fuel facilities that must be in place before a spill occurs Preliminary spill mitigation strategies 1.1
More informationPapua New Guinea LNG Project. Environmental and Social Management Plan Appendix 6: Spill Prevention and Response Plan PGGP-EH-SPENV
Esso Highlands Limited Papua New Guinea LNG Project Environmental and Social Management Plan Appendix 6: Spill Prevention and Response Plan PGGP-EH-SPENV-000018-008 LNG Project Page 2 of 14 CONTENTS 1.0
More informationQuestion Yes No. 1. Is the study interventional (a clinical trial)? Study Type data element is Interventional
Checklist for Evaluating Whether a Clinical Trial or Study is an Applicable Clinical Trial (ACT) Under 42 CFR 11.22(b) for Clinical Trials Initiated on or After January 18, 2017 1 (NOT FOR SUBMISSION 2
More informationAWMA SPCC & FRP Workshop
AWMA SPCC & FRP Workshop Facility Response Plans (40 CFR 112 Subpart D) Des Moines, IA November 2013 Gene Taylor, PE FRP Program Goal is to ensure that SH facilities have adequate oil spill response capabilities
More informatione-cfr Data is current as of October 16, 2017
e-cfr Data is current as of October 16, 2017 Title 40: Protection of Environment PART 63 NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES Subpart BBBBBB National Emission
More informationThis guidance applies to those individuals working with HW Satellite Accumulation Area aboard Marine Corps Logistics Base (MCLB) Barstow.
Environmental Standard Operating Procedure (Approved by Jonathan Aunger) Document Owner: Environmental Division M. Bracey File Name: HWA-ESOP 02H006v3 Effective Date: 1 October 2007 Revised: 14 April 2015
More informationSector Houston Galveston Captain Brian Penoyer Sector Commander
Captain Brian Penoyer Sector Commander NRC Notifications RRT Activations Federal Projects CERCLA Projects 95 01 Surface Washing Agents 00 In situ Burns 00 Dispersants 02 01(EPA lead) COTP Reports 1 Shell
More informationLARGE QUANTITY GENERATOR CHECKLIST
Facility: Date: LARGE QUANTITY GENERATOR CHECKLIST Note: The Oklahoma Hazardous Waste Management Regulations [OK Adm. Code (OAC) 252:205] incorporates by reference at OAC 252:205-3-2 the applicable federal
More informationColonial Pipeline Company. Regional Response Team Meeting Jersey City, NJ 6/14/18
Colonial Pipeline Company Regional Response Team Meeting Jersey City, NJ 6/14/18 Colonial Pipeline Company Interstate common carrier of refined petroleum products: Headquartered in Alpharetta, GA Pipeline
More informationOWNER USER INTEGRITY MANAGEMENT SYSTEM WRITTEN DESCRIPTION CHECKLIST AB-512(b)
Company Name: Written Description of QMS Title and Rev. Status: Person who is responsible for preparing the owner s QMS written description: Name: Title: Telephone No.: ( ) Fax No.: ( ) Cell No.: ( ) E-Mail:
More informationEnvironmental Management Chapter ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT LAND DIVISION - HAZARDOUS WASTE PROGRAM ADMINISTRATIVE CODE
ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT LAND DIVISION - HAZARDOUS WASTE PROGRAM ADMINISTRATIVE CODE CHAPTER 335-14-3 IDENTIFICATION AND LISTING OF HAZARDOUS WASTE TABLE OF CONTENTS 335-14-3-.01
More informationEPA Region 2 Update. Presenter: Francesco Maimone Oil Enforcement Coordinator Date: November 9, 2016 For: 4 th NY Storage Tank Conference
EPA Region 2 Update 1 Presenter: Francesco Maimone Oil Enforcement Coordinator Date: November 9, 2016 For: 4 th NY Storage Tank Conference \ Environmental Protection Agency 2 Overview of Tank-Related Regulatory
More informationSector Delaware Bay. Captain Kathy Moore Sector Commander COTP Report to RRT II 21 SEP MAR 2014 Oil Spill Reports
Sector Delaware Bay Captain Kathy Moore Sector Commander Kathleen.moore@uscg.mil NRC Notifications COTP Report to RRT II 21 SEP 2013 31 MAR 2014 Oil Spill Reports HAZMAT Release Reports 214 64 16 RRT Activations
More informationTitle 40 Code of Federal Regulations NSPS 60, Subpart WWW Checklist for Conditions and Requirements Municipal Solid Waste Landfills (MSWLF)
Check the most Appropriate Answer and fill in the blanks as appropriate. 40 CFR 60.750 Applicability, designation of affected facility, and delegation of authority see separate checklist for Applicability
More informationSMALL QUANTITY GENERATOR CHECKLIST
SMALL QUANTITY GENERATOR CHECKLIST Note: The Oklahoma Hazardous Waste Management Regulations [OK Adm. Code (OAC) 252:205] incorporates by reference at OAC 252:205-3-2 the applicable federal hazardous waste
More informationSEVENTEENTH DISTRICT MARINE SAFETY INFORMATION BULLETIN (MSIB) ALTERNATIVE PLANNING CRITERIA GUIDELINES FOR NON-TANK VESSELS IN ALASKA
Commander Seventeenth Coast Guard District PO Box 25517 Juneau Alaska 99802-5517 Staff Symbol: (dpi) Phone: (907) 463-2805 Email: Michael.E.DeLury@uscg.mil CGD17 MSIB 01-15 XX AUGUST 2015 SEVENTEENTH DISTRICT
More informationMUNICIPAL SOLID WASTE LANDFILLS (Adopted and Effective 6/17/98)
RULE 59.1 MUNICIPAL SOLID WASTE LANDFILLS (Adopted and Effective 6/17/98) (a) APPLICABILITY (1) Except as provided in Section (b) below, this rule is applicable to each existing municipal solid waste (MSW)
More informationMontreal Pipe Line Limited Emergency Management Program:
Montreal Pipe Line Limited Emergency Management Program: Introduction: As stated in the Montreal Pipe Line Limited (MPLL) Corporate Policy on the Environment MPLL will manage our business with the goal
More informationSUBJECT: PCSOPEP and OSRO Requirements for the Panama Canal (Revision 1)
October 13, 2003 MR S ADVISORY TO SHIPPING No. A-38-2003 TO: All Steamship Agents, Owners, and Operators SUBJECT: PCSOPEP and OSRO Requirements for the Panama Canal (Revision 1) Since the publication of
More informationSanitary Sewer Overflow Response Plan
Sanitary Sewer Overflow Response Plan System Name: GMS ID: Address: City/State/Zip: Phone Number: Fax: Email: FLORIDA RURAL WATER ASSOCIATION 2970 Wellington Circle Tallahassee, FL 32309-7813 Phone: (850)
More informationGAS. Gas Distribution Systems Safety and Loss Management System Guidelines. Prepared by: Brad Wyatt, Provincial Safety Manager - Gas
GAS Gas Distribution Systems Safety and Loss Management System Guidelines Prepared by: Brad Wyatt, Provincial Safety Manager - Gas Date: November - 2017 Controlled Document: MAN-4057-00 Contents 1. Introduction...
More informationSpill Prevention Control and Countermeasure Plan Buckeye Brine, LLC Riverside Recycling Facility Tuscarawas, Ohio
Spill Prevention Control and Countermeasure Plan Buckeye Brine, LLC Riverside Recycling Facility Tuscarawas, Ohio December, 2013 SPCCP - Revision 1.0.0 Page 2 of 7 A. Foreword Buckeye Brine, LLC is committed
More informationSubj: CH-2 to 03-03, IMPLEMENTATION GUIDANCE FOR THE REGULATIONS MANDATED BY THE MARITIME TRANSPORTATION SECURITY ACT OF 2002 (MTSA) FOR FACILITIES
U.S. Department of Commandant 2100 2" ST SW Homeland United States Coast Guard Washington DC 20593-0001 United States Staff Symbol: (CG-544) Phone: (202) 372-1000 Coast Guard COMDTPUB P 16700.4 NVIC 03-03
More informationSubj: CH-2 to 03-03, IMPLEMENTATION GUIDANCE FOR THE REGULATIONS MANDATED BY THE MARITIME TRANSPORTATION SECURITY ACT OF 2002 (MTSA) FOR FACILITIES
U.S. Department of Commandant 2100 2" ST SW Homeland United States Coast Guard Washington DC 20593-0001 Staff Symbol: (CG-544) United States Phone: (202) 372-1000 Coast Guard COMDTPUB P 16700.4 NVIC 03-03
More informationSITE SPECIFIC SPILL PLAN For use of this form, see the Installation Spill Contingency Plan; the proponent is DPW-ENRD
POST THIS PAGE PROMINENTLY AT EACH HAZARDOUS WASTE SATELLITE ACCUMULATION POINT, 90-DAY HW SITE, HAZARDOUS MATERIAL STORAGE AREA, AND SPCC CONTAINER STORAGE AREA Spill Response Call 911 for all spills
More informationSubpart G Emergency Response Information
Pipeline and Hazardous Materials Safety Admin., DOT 172.602 (b) In addition to conformance with 172.519, the background on the CLASS 9 placard must be white with seven black vertical stripes on the top
More informationCHEMICAL TANK VESSEL INFORMATION SHEET (CTVIS)
Commanding Officer United States Coast Guard Marine Safety Center 2100 2 nd Street S.W., Stop 7102 Washington, DC 20593-7102 Staff Symbol: MSC-3 Phone: (202) 475-3403 Fax : (202) 475-3920 CHEMICAL TANK
More informationPipeline & Hazardous Materials Safety Administration (PHMSA)
Pipeline & Hazardous Materials Safety Administration (PHMSA) Notice of Proposed Rulemaking: Oil Spill Response Plans and Information Sharing for High-Hazard Flammable Trains PHMSA Office of Hazardous Materials
More informationSchedule C Fuel Loading/Unloading Operation Procedure Tristar Terminals Guam, Inc. TRISTAR Agility Document Information Rev. No. Doc. Number Doc. Description Prepared By Reviewed By Approved By 02 TIGI-PRC-HSE-12
More informationMaintenance Program Guideline for Owners of Ammonia Plants
Maintenance Program Guideline for Owners of Ammonia Plants Contents Maintenance Program Guideline for Owners of Ammonia Plants... 0 a) Title Page, owner/operator, the plant location.... 4 b) Contents Page...
More informationFEMA Region 10 Tribal Mitigation Plan Review Tool
FEMA Region 10 Tribal Mitigation Plan Review Tool The Tribal Mitigation Plan Review Tool records how the tribal mitigation plan meets the regulations in 44 CFR 201.7 and 201.5 (if applicable) and offers
More informationHazardous Waste Small Quantity Generator Checklist
Facility Name DEQ Representative(s) EPA ID NUMBER Date 1. Does the generator ever accumulate a quantity of hazardous waste greater than 6,000 kilograms? (If YES, then use 5. Generator Checklist or Unauthorized
More informationBRIGHAM YOUNG UNIVERSITY IDAHO ENVIRONMENTAL, HEALTH & SAFETY SAFETY DEPARTMENT ACCIDENTAL SPILL PREVENTION PLAN EH-009-R03
BRIGHAM YOUNG UNIVERSITY IDAHO ENVIRONMENTAL, HEALTH & SAFETY SAFETY DEPARTMENT ACCIDENTAL SPILL PREVENTION PLAN EH-009-R03 Department Title: Safety Department Page: 1 Department Title: Safety Department
More informationAPVG-GP-T SUBJECT: Annex U (Environmental Compliance) to Pohakuloa Training Area (PTA) External Standing Operating Procedures (SOP).
1. PURPOSE. Provide general policy and procedures for supported units who use and/or generate Hazardous Material (HM)/Hazardous Waste (HW) at PTA. 2. APPLICABILITY. This annex is applicable to all supported
More informationThe New (and final) SPCC Rule
Brett D. Smith, PE, PG OVERVIEW History of the Spill Rule (40 CFR Part 112) July 2002 final rule - changes December 2006 amendments - changes BREAK - 15 minutes Definitions of key terms 40 CFR 112 - exempt
More informationSCHEDULE A. Fuel Farm Operations Manual
SCHEDULE A Fuel Farm 1. Geographic Location of the Facility G.P.A. Bulk Fuel Storage Facility Harbor of Refuge Piti, GU 96913 The Guam Power Authority Bulk Fuel Storage Facility is located on the Eastern
More informationNRC Corporate Overview Regional Response Team 5 (RRT5) Cleveland, OH November 5-6, 2013
Excellence in Environmental & Emergency Solutions NRC Corporate Overview Regional Response Team 5 (RRT5) Cleveland, OH November 5-6, 2013 NRC Customer Base Servicing: Petroleum and Dry Cargo Shipping Oil
More informationMTSA FACILITY COMPLIANCE GUIDE
United States Coast Guard Name of Facility/Location: Facility Type: Facility ID Number: MISLE Activity Number: Inspection Type Full or Spot Check: Areas Inspected: (ex. G-14, N-28-30 or All) Date(s) Conducted:
More informationSPILL PREVENTION & RESPONSE
Revision Page: Page 1 of 13 Purpose The purpose of this plan is to document spill prevention and response requirements. Each HOUSTON, INC work site will develop a spill prevention and response plan based
More informationTable of Contents Implementation Guidance for the Regulations Mandated by the Maritime Transportation Security Act of 2002 (MTSA) for Facilities
Table of Contents Implementation Guidance for the Regulations Mandated by the Maritime Transportation Security Act of 2002 (MTSA) for Facilities Enclosure (1) Plan Review Guidance Flowchart Enclosure (2)
More informationAppendix C3 Spill Prevention, Containment, and Countermeasures Plan Framework
Appendix C3 Spill Prevention, Containment, and Countermeasures Plan Framework THIS PAGE INTENTIONALLY LEFT BLANK TABLE OF CONTENTS C3.1 Purpose... C3-1 C3.2 Responsibility of Implementation... C3-2 C3.3
More informationFlorida Fish and Wildlife Conservation Commission Internal Management Policies and Procedures (IMPP) Bulk Fuel Use #5.12
Florida Fish and Wildlife Conservation Commission Internal Management Policies and Procedures (IMPP) TITLE IMPP Bulk Fuel Use #5.12 EFFECTIVE DATE 03/31/2016 APPLICABILITY RESCINDS/AMENDS ALL MEMBERS 10/06/2003
More informationSector New Orleans. Captain Peter Gautier Sector Commander
Sector New Orleans NRC Notifications RRT Activations Federal Projects CERCLA Projects 402 00 Surface Washing Agents 00 In situ Burns 00 Dispersants 3 1 5/19/2014 COTP Reports 1 Harvest Pipeline Discharge
More informationCLOSURE PLAN ASH LANDFILL AREA SPRINGERVILLE GENERATING STATION SPRINGERVILLE, ARIZONA
CLOSURE PLAN ASH LANDFILL AREA SPRINGERVILLE GENERATING STATION SPRINGERVILLE, ARIZONA Prepared for Tucson Electric Power Company October 14, 2016 Prepared by AMTECH Associates, L.L.C. 8666 E. San Alberto
More informationRelease Reporting Requirements. Stoel Rives LLP
Release Reporting Requirements By Stoel Rives LLP I. INTRODUCTION Unexpected Problems Scope of Remarks Unexpected Problems Scenarios Unexpected Release - Your plant operator calls you in the middle of
More informationHurricane Katrina: August 28, 2005
Hurricane Katrina: August 28, 2005 Hurricane Katrina: August 28, 2005 Hurricane Katrina Hurricane Rita: September 24, 2005 Hurricane Rita: September 24, 2005 House in the
More informationNATIONAL ENERGY BOARD ONSHORE PIPELINE REGULATIONS
PDF Version [Printer-friendly - ideal for printing entire document] NATIONAL ENERGY BOARD ONSHORE PIPELINE REGULATIONS Published by Quickscribe Services Ltd. Updated To: [includes Federal Regulation SOR/2016-134
More informationProduced Water Quality Recyling & Reuse CFR112 -SPCC Kathleen Atencio, Preparedness Unit Chief
Produced Water Quality Recyling & Reuse 2016 40CFR112 -SPCC Kathleen Atencio, Preparedness Unit Chief Legal disclaimer EPA has made every effort to ensure the accuracy of this presentation. However, please
More informationCCC-PLN-Pollution Incident Response Management Plan
CARROLL COTTON POLLUTION INCIDENT RESPONSE MANAGEMENT PLAN Page 1 of 10 1 PURPOSE The purpose of this plan is to: Ensure comprehensive and timely communication about a pollution incident to staff at the
More informationAPPLICATION REVIEW CHECKLIST LAND PROTECTION DIVISION HAZARDOUS WASTE PROGRAM OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY TECHNICALLY ADMIN.
Revised 02/01 APPLICATION REVIEW CHECKLIST LAND PROTECTION DIVISION HAZARDOUS WASTE PROGRAM Facility Name: Facility ID No.: ODEQ Permit No.: Reference No.: _ Application Type: Date: (New/Modify/Renewal)
More informationRegulatory Guide 2.19
Regulatory Guide 2.19 Issuance Date: December 1, 2011 Guide for Submission of Documents and Fees by Low Level Radioactive Waste Shippers and Transporters I. INTRODUCTION A. Approval Process Radiation Safety
More informationCalifornia Hazardous Materials Spill / Release Notification Guidance
California Hazardous Materials Spill / Release Notification Guidance To Report all significant releases or threatened releases of hazardous materials: First Call: 9-1-1 (or local emergency response agency)
More informationEnvironmental Standard Operating Procedure Originating Office: Natural Resources and Environmental Affairs Office
Environmental Standard Operating Procedure Originating Office: Natural Resources and Environmental Affairs Office Revision: N/A Prepared By: NREA Subject Matter Expert (SME) Approved By: Patrick Mills
More informationWELL CONTROL AND SPILL RESPONSE PLANNING
Scotian Basin Exploration Program WELL CONTROL AND SPILL RESPONSE PLANNING BP s Scotian Basin Exploration Program involves drilling an initial well on Exploration Licence (EL) 2434 in 2777 metres water
More informationHazardous Materials Section. California Hazardous Material Spill/Release Notification Guidance To Report
California Hazardous Material Spill/Release Notification Guidance To Report all significant releases or threatened releases of hazardous materials, First Call 9-1-1 (or the local emergency response agency)
More informationTABLE OF CONTENTS 1.0 INTRODUCTION...
Advisory Circular Subject: Implementation Procedures for Safety Management Systems for Air Traffic Services Operations Certificate Holders Issuing Office: Civil Aviation Activity Area: Qualifying Document
More informationHazard Communication Program. University of San Diego
Hazard Communication Program University of San Diego Effective September 30, 2013 1. Introduction and Purpose The University of San Diego is firmly committed to providing each of its employees a safe and
More informationFACILITY SECURITY PLAN (FSP) REVIEW CHECKLIST
FACILITY SECURITY PLAN (FSP) REVIEW CHECKLIST Facility ID Number: MISLE Activity Number: Date(s) Conducted: CG Unit: 1 st Reviewer: 2 nd Reviewer: Guidance for completing the Facility Security Plan (FSP)
More informationEnvironmental Protection Agency (EPA), Region 7 Variances to Water Quality Standards Procedural Guidelines
Environmental Protection Agency (EPA), Region 7 Variances to Water Quality Standards Procedural Guidelines Background on EPA s Variance Provision A variance is a temporary modification to the designated
More informationFlagship. A Safety Management System for Members of the Passenger Vessel Association. Revised May 2017
Flagship A Safety Management System for Members of the Passenger Vessel Association Revised May 2017 Note: The PVA Flagship Safety Management System (SMS) and all associated documents are the exclusive
More informationGraphs as required by 46 CFR (b)(3) Curve of Loading Rate vs. Pressure Drop
Graphs as required by 46 CFR 39.30-1(b)(3) Curve of Loading Rate vs. Pressure Drop Conrad Orange Shipyard Hulls H483, H484 * Pressure Drop in VCS (psig) 1.00 0.95 0.90 0.85 0.80 0.75 0.70 0.65 0.60 0.55
More informationRS/GIS Workshop 2015 Baton Rouge, Louisiana
RS/GIS Workshop 2015 Baton Rouge, Louisiana The First Ever Louisiana Geographic Response Plans Presented by: David Gisclair Louisiana Oil Spill Coordinator s Office Office of Public Safety dgisclair@lsu.edu
More informationNATIONAL CONTINGENCY PLAN FOR OIL POLLUTION PREPAREDNESS AND RESPONSE
Translation NATIONAL CONTINGENCY PLAN FOR OIL POLLUTION PREPAREDNESS AND RESPONSE Chapter I Preamble Section 1 - Purpose of the Plan Japan, as a country surrounded by the sea and rich in natural environment,
More information49 CFR PART 172. Subpart I Security Plans
Communications 0 49 CFR PART 172 Subpart I Security Plans Lion Technology Inc. Page 365 49 CFR 172.800 Hazardous Materials Transportation 49 CFR PART 172 Subpart I Safety 0 and Security Plans Sec. 172.800
More informationStormwater Pollution Prevention Training For Olmsted County Solid Waste Facilities. Olmsted County Environmental Resources Department
Stormwater Pollution Prevention Training For Olmsted County Solid Waste Facilities Olmsted County Environmental Resources Department October 2011 Why? This stormwater training program was developed to
More informationDocument Owner: Approval: Revision: 4. EMS Technical Support Environmental Division Chief Original Date: 11 July 2003
Joint Base Lewis-McChord (JBLM) Procedure: Preventative and Corrective Action Document ID: EMS-255 Document Owner: Approval: Revision: 4 ////ORIGINAL SIGNED//// ////ORIGINAL SIGNED//// Revision Date: 9
More informationGeneral Document or OQE Comments SAT UNSAT
4 Quality Management System 4.2.2 Quality Manual (A) Has a Quality Manual been developed that includes the scope of the QMS, the documented procedures established for Section 2 #1 the QMS, and a description
More informationWelding, Burning and Hot Work Safe Practices Plan
Purpose Welding, Burning and Hot To establish procedures for safely conducting welding, burning, cutting and other hot work activities in accordance with BSEE regulations (30 CFR 250.109 113). Scope This
More informationSPILL PREVENTION AND CONTROL (SPC) PLAN FOR OIL STORAGE AREAS TULANE UNIVERSITY
SPILL PREVENTION AND CONTROL (SPC) PLAN FOR OIL STORAGE AREAS TULANE UNIVERSITY Office of Environmental Health and Safety (504) 988-5486 FAX (504) 988-1693 Date: May 5, 2009 Revised: November 23, 2009
More informationAssessing the Human Health Effects of the Gulf of Mexico Oil Spill: An Institute of Medicine Workshop. June 22, 2010
Assessing the Human Health Effects of the Gulf of Mexico Oil Spill: An Institute of Medicine Workshop June 22, 2010 John Howard, M.D. National Institute for Occupational Safety and Health Centers for Disease
More informationSPILL CONTINGENCY PLANNING REGULATION
Environmental Management Act SPILL CONTINGENCY PLANNING REGULATION B.C. Reg. 186/2017 Deposited October 13, 2017 and effective October 30, 2017 Consolidated Regulations of British Columbia This is an unofficial
More informationMSC Guidelines for Review of Oceangoing Tank Barge Cargo Authority Procedure Number: C1-42 Revision Date: 08/01/2018
S. M. PETERSON, LCDR, Chief of Tank Vessel and Offshore Division Purpose: The purpose of this document is to provide guidance and information regarding the submission of the Tank Group Characteristics
More informationChemical Hygiene Plan
Chemical Hygiene Plan The UAB Department of Occupational Health and Safety requires each laboratory on campus to develop and abide by a written Chemical Hygiene Plan (CHP) as outlined by the U.S. Occupational
More informationALLIANT ENERGY WISCONSIN POWER AND LIGHT NELSON DEWEY GENERATING STATION CCR SURFACE IMPOUNDMENT ANNUAL INSPECTION REPORT.
ALLIANT ENERGY WISCONSIN POWER AND LIGHT NELSON DEWEY GENERATING STATION CCR SURFACE IMPOUNDMENT ANNUAL INSPECTION REPORT January 15, 2016 EXECUTIVE SUMMARY This annual inspection report has been prepared
More informationFACILITY NAME: NJPDES PERMIT NO.: PAGE 1 of 5 (new applicants leave blank) TRANSFER - ZG
FACILITY NAME: NJPDES PERMIT NO.: PAGE 1 of 5 NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION DIVISION OF WATER QUALITY Form R Transfer Station - ZG Refer to Appropriate Completeness Checklist and Instructions.
More informationStorm Water Pollution Prevention Plan for CES Gravel #3800
David Lewis Cell: (870) 310-2757 Rickey Vaughn Cell: (870) 310-9602 Buddy McAdams Cell: (870) 310-8733 Local (870) 881-8830 Fax: (870) 881-8809 LICENSED, BONDED & INSURED Howard Cupp, Jr. Cell: (870) 314-2877
More informationPRE-FIRE PLAN CERTIFICATION
PRE-FIRE PLAN CERTIFICATION Florida Marine Transporters, Inc. 3000 Series (See attached vessel list) This Certificate is issued in accordance with 33CFR155.4035, Paragraph (b) (2) T&T SALVAGE, LLC, as
More informationExcavation Monitoring and Observation
Purpose Reference Appendices Related Toolbox Topics This document contains items to consider when developing a process to monitor or observe excavation activity after a one-call ticket has been analyzed
More informationLEGISLATURE 2017 BILL
0-0 LEGISLATURE LRB-/ 0 AN ACT to create 0. () (h),.0 (),.,.,. and. () (a). of the statutes; relating to: preparation and response required by railroad corporations in the event of discharge of transported
More informationPart 148 Aircraft Manufacturing Organisation
Part 148 Compliance Matrix The rule references in this compliance matrix have been extracted from the Civil Aviation Rules system as the minimum compliance requirements for an applicant for the issue or
More informationPrevention Program. Safe and Effective Oil Transfer Operations
Prevention Program Safe and Effective Oil Transfer Operations Washington State Department of Ecology Spill Prevention, Preparedness and Response Program Harbor Safety Committee Conference - 2008 WA Prevention
More informationCOMPLIANCE ASSISTANCE VISIT REPORT
Georgia Department of Natural Resources 2 Martin Luther King, Jr. Dr., S.E., Suite 1066 East, Atlanta, Georgia 30334 Mark Williams, Commissioner Environmental Protection Division F. Allen Barnes, Director
More informationIII. LEGAL AUTHORITIES
Inter-agency Memorandum of Agreement Regarding Oil Spill Planning and Response Activities Under the Federal Water Pollution Control Act's National Oil and Hazardous Substances Pollution Contingency Plan
More information