25 BED PORTABLE NATIONAL DIALYSISCENTER

Size: px
Start display at page:

Download "25 BED PORTABLE NATIONAL DIALYSISCENTER"

Transcription

1 25 BED PORTABLE NATIONAL DIALYSISCENTER

2 PORTABLE NATIONA L DIA LYSIS CENTER SCOPE OF WORK: HBAIL will develop a start to finish turnkey operation portable National Dialysis Center (NDC). The NDC is a complex of twenty eight (28) custom fabricated 45ft high cube shipping containers, uniquely designed for this purpose. The NDC is an 8,290 sq. ft. clinic providing space for eight (08) major sections: - 25 Bed Dialysis Center including nurse stations, restrooms, changing rooms and staff area. - Reception waiting area. - 9 Medical Examination offices fully equipped. - Blood Donor Center with 6 Beds including Blood processing center lab. - Administration / Staff Area. - X-Ray Department including CT scan, Mammography, General X-Ray, Lab and Offices. - Water treatment & storage. - Renewable Power Energy Station. The NDC is a 100% self-sustainable system, including its own power generation with renewable energy package, water treatment center, climate control system and satellite system for internet/communications. The NDC is designed to function as one large center or it can be divided into smaller sub-sections that can be dispatched to remote locations. The NDC is fully designed and fabricated in California, USA and meets the highest industry standards of quality control.

3 1.0 RECEPTION AREA: 1.1 Reception area fully furnished office for up to four (04) staff members 1.2 Wiring for office equipment, network and internet system included. 1.3 Seating /waiting area for up to 26 adults. 1.4 Two (02) full size restrooms with wheel chair access. 1.5 Intercom system throughout. 1.6 Direct access to Blood Donor Center, Exam areas and Dialysis Center. Page 2 of 14

4 2.0 BLOOD DONOR / LAB AREA: 2.1 Blood Donor area with six (06) custom designed beds. 2.2 Blood collection scale units with shaker system, for each bed 2.3 Welsh Allyn Diagnostic system on wall for each blood donor bed. 2.4 Wall mounted entertainment system with headsets for each donor bed. 2.5 Workstations distributed throughout area. 2.6 Power outlets with CAT6 network throughout. 2.7 Panic button with paging system for each bed. 2.8 Blood lab area including: Two (02) Blood refrigerators 50 cu. ft. with temperature control process #BB-48-HG-TP One (01) Blood refrigerator 4.9 cu. ft. (REB404D) One (01) Analyzer, Hematology Mindray BC Two (02) Scale, Digital Health O Meter w/height rod -Digital Four (04) Genesis model blood bag sealers model 428-SE Two (02) Blood grouping ORTHA Pro Value One (01) under counter SLR104-ADA lab fridge 2.9 Lab equipment storage space with adjustable shelves Full size restrooms - wheelchair accessible. Page 3 of 14

5 3.0 ADMINISTRATION / STAFF AREA: 3.1 Administrator s office equipped with teleconferencing capabilities. 3.2 IT room (All network, and communications area). 3.3 Office/administration supplies room. 3.4 Staff lunch/break room equipped with: Galley area with sink and trash collector cu. ft. refrigerator/fridge Microwave Overhead cabinet for supplies Wall mounted TV entertainment system Lunch table Folding chairs. Page 4 of 14

6 4.0 MEDICAL EXAMINATION AREA: 4.1 Nine (09) Doctor s examination rooms, equipped as follows: Midmark Ritter 204 exam beds with recliner back and drawers Floor mount exam lights Wall mounted diagnostic lit Welsh Allyn unit Counter section with stainless steel sink (hot and cold water) Weight scale with height rod Overhead cabinets for medical supply storage Doctor s workstation desk pre-wired computer and accessories Wall mounted hand free intercom system connected to nurse stations Sharp disposal container (biohazardous ) Doctor s stool air lift X-Ray viewer wall mounted Network connections throughout. Page 5 of 14

7 5.0 X-RAY AREA: 5.1 CT Scan Room - includes CT scanner Philips model Ingenuity CT. 5.2 CT Scan room is fully insulated per manufacturer s recommendations. 5.3 Dressing room with locker included in the CT Room. 5.4 Mammography X-Ray Room - Selenia model by Hologic. Room includes dressing area. 5.5 One (01) X-Ray Lab room - full lab for X-ray equipment and accessories. 5.6 One (01) Doctor s office for X-Ray analyzes and patient meeting. 5.7 One (01) supply room. Page 6 of 14

8 6.0 DIALYZIS CENTER: 6.1 Twenty five (25) dialyses cubicles equipped with dialyses bed (model TM17918) and Althin System Drake Willcok 480B.UF dialysis machines. 6.2 Each dialysis cubicle includes entertainment center, panic button and intercom system. 6.3 Five (05) spare (back up) dialysis beds included in the storage room. 6.4 Five (05) spare (back up) dialysis machines included in the storage room. 6.5 Whole house reverse Osmosis System 5000GPD 220 volt system. 6.6 Three (03) nurse stations, fully wired for computers and network system 6.7 Four (04) dressing rooms strategically located in the dialysis area. 6.8 Two (02) restrooms with storage in the dialysis area. 6.9 One (01) main nurse/administration office Two (02) storage supply rooms Hands free intercom system at nurse stations. Page 7 of 14

9 7.0 RENEWABLE ENERGY POWER STATION: 7.1 Power Turbine generator 700 Kw - Spirit 1 MW model in a fully contained section. 7.2 This power turbine uses dual fuel - diesel or propane gas. 7.3 Complete wiring system throughout NDC, including power load sections with auto reset breaker system. 7.4 Wiring meets applicable NEC, SAE standards. (Color coded). Page 8 of 14

10 8.0 WATER TREATMENT SYSTEM: 8.1 Self-contained water storage and treatment. 8.2 System provides 2,000 gallons of fresh water including filtration system 8.3 On demand water pumps with back-up system, including self-automated system. 8.4 Recycling water and waste system self-contained. Page 9 of 14

11 9.0 COOLING AND HEATING SYSTEMS: 9.1 Centralized air conditioning system Norcold system. 9.2 Includes centralized thermostat units for each major section with multi zone temperature control. 9.3 Air filtration system included in each discharge area. 9.4 Heating system built in to the air conditioning system with heat mode LIGHTING SYSTEM: 10.1 Celling lights recessed fluorescent type Emergency lights located at exit areas and corridors Backup power for lighting system included Exterior lights on all perimeter of the NDC Wall mount light switches on each room and as required OTHER SERVICES INCLUDED IN THE PROPOSAL: 11.1 Factory s training for 30 (thirty) days, for up to ten (10) people Factory training covers all areas of deployment /assembly, trouble-shooting, maintenance routines, equipment operation and proper service Factory s training cost (air tickets round trip and hotel accommodations) are included Full owner s manuals Full drawings (electrical schematics, plumbing, and assembly structural) included Online training and video support. Page 10 of 14

12 INTELLECTUAL PROPERTY: Customer acknowledges that HBAIL GROUP owns all rights, design, layout and models to the medical units (0s) to be manufactured, including without limitation all Intellectual Property Rights." Intellectual Property Rights" means any and all rights existing from time to time under patent law, copyright law, trade secret law, trademark law, unfair competition law, and any and all other proprietary rights, and any and all applications, renewals, extensions and restorations thereof, now or hereafter in force and effect worldwide. Customer agrees not to modify, adapt, translate, prepare derivative works from, decompile, reverse engineer, disassemble or otherwise attempt to derive source code from HBAIL GROUP. Customer also agrees to not remove, obscure, or alter HBAIL GROUP s copyright notice, trademarks, or other proprietary rights notices affixed to or contained within or accessed in conjunction with or through the. HBAIL GROUP LIMITED WARRANTY: HBAIL GROUP does hereby warrant the services provided by HBAIL GROUP for the period of 36 months or 36,000 miles, whichever occurs first, following the date of shipment ( Warranty Period ). This warranty covers services and labor only. All parts installed as a part of the services provided by HBAIL GROUP shall be covered by the manufacturer s warranty, and Customer agrees to rely only upon such manufacturer s warranty(ies). Customer shall have no recourse against for HBAIL GROUP any defects in the parts utilized. This warranty is limited to defect in workmanship and does not cover any damage caused by intervening of third-parties and/or improper use by Customer. If a defect in workmanship is determined during the Warranty Period, Customer shall promptly notify HBAIL GROUP of any of the defect and shall allow HBAILGROUP the opportunity to complete repairs of the defective workmanship. Customer s sole and exclusive remedy and HBAIL GROUP s sole and exclusive liability shall be limited to the repair of the defective workmanship. If Customer fails to promptly notify HBAIL GROUP of the alleged defect in workmanship and allow HBAIL GROUP the opportunity to repair the defect, Customer shall have no other remedy at law. THIS WARRANTY IS PROVIDED TO CUSTOMER IN LIEU OF ALL OTHER EXPRESS OR IMPLIEDWARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, WHICH ARE DISCLAIMED HEREUNDER; HOWEVER, IF SUCH IMPLIED WARRANTIES AREREQUIRED AS A MATTER OF LAW, SUCH WARRANTIES ARE LIMITED IN DURATION TO THE WARRANTY PERIOD. Page 14 of 14

13 Page 14 of 14

Owner s Manual Calcite Cartridge System

Owner s Manual Calcite Cartridge System Owner s Manual Calcite Cartridge System Page 2 Copyright 2011 Enviro Water Solutions, Inc. All rights reserved. All information contained herein is the property of Pelican Water Technologies. Pelican Water

More information

SECTION A-A. Blower Housing. Settling Zone Volume times daily flow. Treatment Zone. SaniTEE 818-B. Vent. Shutoff Valve.

SECTION A-A. Blower Housing. Settling Zone Volume times daily flow. Treatment Zone. SaniTEE 818-B. Vent. Shutoff Valve. A Shutoff Valve Influent Distribution Box See note 11 Volume 0.5-1 times daily flow Mixing Pump Recirculation Pump Discharge SaniTEE 818-B Recirculation Pump Vent Control Panel Blower Housing A NOTES 1.

More information

FROST TOP - WF SERIES

FROST TOP - WF SERIES FROST TOP - WF SERIES Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.

More information

Model 5200 Cargo Lift Installation and Operation Manual

Model 5200 Cargo Lift Installation and Operation Manual Model 5200 Cargo Lift Installation and Operation Manual Congratulations on the purchase of your new SpaceLift Products 5200 cargo lift system. Expect to receive many years of reliable service moving household

More information

Instructions and E00 Series Sampling Module Extenders

Instructions and E00 Series Sampling Module Extenders Instructions 012-1568-00 and 012-1569-00 80E00 Series Sampling Module Extenders 071-0436-01 www.tektronix.com 071043601 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by

More information

Model 5200 Cargo Lift Installation and Operation Manual

Model 5200 Cargo Lift Installation and Operation Manual Model 5200 Cargo Lift Installation and Operation Manual Congratulations on the purchase of your new SpaceLift Products 5200 cargo lift system. Expect to receive many years of reliable service moving household

More information

Installation Manual. All-In-One Shower Panel System. Copyright ShopRangeHoods.com 2016 Office: +1 (626)

Installation Manual. All-In-One Shower Panel System. Copyright ShopRangeHoods.com 2016 Office: +1 (626) Installation Manual All-In-One Shower Panel System Copyright ShopRangeHoods.com 2016 Office: +1 (626) 321-9834 Email: support@shoprangehoods.com Distributed by ShopRangeHoods.com Manufactured by AKDY FOR

More information

SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard

SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard PART 1 GENERAL 1.1 Scope A. The intent of this specification is to provide power control for the parallel operation of generator

More information

INSTRUCTION MANUAL PHANTOM LOAD MODEL PA For SERIAL NO.

INSTRUCTION MANUAL PHANTOM LOAD MODEL PA For SERIAL NO. INSTRUCTION MANUAL For PHANTOM LOAD MODEL PA-305 SERIAL NO. It is essential that this instruction book be read thoroughly before putting the equipment in service. IMPORTANT The information and data contained

More information

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Document No. 1800-56 Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

The Culligan Hi-Flo 50 Series Industrial Water Filter System

The Culligan Hi-Flo 50 Series Industrial Water Filter System The Culligan Hi-Flo 50 Series Industrial Water Filter System Durable High-Volume Water Filtration for Industrial Applications The Culligan Hi-Flo 50 Filter reduces contaminants* and solids that affect

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS and Fixed Trapeze Assembly, Installation and Operating Instructions Model Nos. 7714P and 7740P SAVE THESE INSTRUCTIONS NOTE: Check ALL parts for shipping damage. In case of shipping damage, DO NOT use.

More information

Field Economy Unit Instruction Manual

Field Economy Unit Instruction Manual Field Economy Unit Instruction Manual Models CDC3FE-001 CDC3FE-002 CDC3FE-003 Table of Contents 1. General Description............................................................ 2 2. Specifications &

More information

Dental Project. Project 2: Dental Clinic Research and Schematics ID 440 Contract Design II Fall 2009

Dental Project. Project 2: Dental Clinic Research and Schematics ID 440 Contract Design II Fall 2009 Dental Project Project/Class: Project 2: Dental Clinic Research and Schematics ID 440 Contract Design II Fall 2009 Project Statement: This project encompasses a team investigation summarizing the evidence-based

More information

EP-CORKEL2 OWNER S MANUAL

EP-CORKEL2 OWNER S MANUAL Electric Bottle Opener EP-CORKEL2 OWNER S MANUAL EPICUREANIST ELECTRIC BOTTLE OPENER Epicureanist Electric Bottle Opener couples style and functionality, effortlessly opening corked bottles within moments.

More information

SECTION A-A. Control Panel

SECTION A-A. Control Panel SaniTEE 818-B Blower Housing Settling Zone 1050 Gallon MIN 4500 Gallons Control [4000 L MIN] [17000L] Panel 183 MX 72 MX Height of Effluent Line 1. Blower piping to BioBarrier MBR may not exceed 40 FT

More information

SECTION A-A. Blower Housing. SaniTEE 818-B. Shutoff Valve. Influent. Settling Zone Volume times daily flow. Treatment Zone.

SECTION A-A. Blower Housing. SaniTEE 818-B. Shutoff Valve. Influent. Settling Zone Volume times daily flow. Treatment Zone. Shutoff Valve Influent Distribution Box See note 11 SaniTEE 818-B Blower Housing Control Panel NOTES 1. Blower piping to BioBarrier HSMBR may not exceed 40 FT [12 m] total length and use 4 elbows maximum

More information

Model Number: 1300 Series

Model Number: 1300 Series Model Number: 1300 Series Product Description 17" x 14" Stainless Steel Lavatory Simply Stainless Collection 17" x 14" (43.18cm x 35.56cm) with Overflow High-Quality Durable Stainless Steel For Drop-in

More information

c a s s i d y price list october 2018

c a s s i d y price list october 2018 c a s s i d y price list october 2018 terms and conditions Prices and Specifications Prices and specifications are subject to change without notice. All prices quoted will be FOBour factories. If applicable,

More information

Installation Guide. Single AC or Dual AC Sump Pump Installation. 1 AC Primary Pump or 2 AC Pumps with Auxiliary Alternator

Installation Guide. Single AC or Dual AC Sump Pump Installation. 1 AC Primary Pump or 2 AC Pumps with Auxiliary Alternator TM Installation Guide for the Beacon ProActTM 200 System Single AC or Dual AC Sump Pump Installation 1 AC Primary Pump or 2 AC Pumps with Auxiliary Alternator BEACON recommends that this product, like

More information

MNL, SEL DIMENSIONS, SITE AW PLANNING GUIDE ARTWORK SIZE A SHEET 1 OF 1

MNL, SEL DIMENSIONS, SITE AW PLANNING GUIDE ARTWORK SIZE A SHEET 1 OF 1 Artwork and Signature File for: MAN-01120, MNL, SEL DIMENSIONS, SITE PLANNING GUIDE Artwork consists of: Thirty-Six (36) 8 ½ inch x 11 inch sheet(s) attached. REV AUTHORED BY DATE A.TAMBASCIO 01/20/10

More information

OPTO BRANCH 6 RJ45. user manual. ELATION OPTO BRANCH 6 RJ45 user manual

OPTO BRANCH 6 RJ45. user manual. ELATION OPTO BRANCH 6 RJ45 user manual OPTO BRANCH 6 RJ45 user manual ELATION OPTO BRANCH 6 RJ45 user manual 2015 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to

More information

Quick-Start Operating Guide Document No Exhaust Fume Hood Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010

Quick-Start Operating Guide Document No Exhaust Fume Hood Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010 Document No. 1800-65 Exhaust Fume Hood Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL:

More information

"SRMZ" ROOFTOP PACKAGED MULTIZONE UNITS Self Contained Single Package Units 17.5 to 43 Ton Cooling Capacities

SRMZ ROOFTOP PACKAGED MULTIZONE UNITS Self Contained Single Package Units 17.5 to 43 Ton Cooling Capacities "SRMZ" ROOFTOP PACKAGED MULTIZONE UNITS Self Contained Single Package Units 17.5 to 43 Ton Cooling Capacities Packaged Rooftop Multizone shall be Spinnaker Industries Inc. Model Series SRMZ. Units shall

More information

TL-600 MOBILE PHASE HEATER

TL-600 MOBILE PHASE HEATER TL-600 MOBILE PHASE HEATER INSTRUCTION MANUAL Timberline Instruments, Inc. 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx: (303) 440-8786 info@timberlineinstruments.com www.timberlineinstruments.com

More information

SECTION ENGINEER'S OFFICE

SECTION ENGINEER'S OFFICE 01200-1 of 5 SECTION 01200 ENGINEER'S OFFICE 01200.01 GENERAL A. Description This item shall consist of furnishing and maintaining in good condition a suitable office in a location acceptable to the Engineer

More information

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017 Installation Guide Document No. 1788-01 Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL:

More information

instructions 8 x 4 ft Proslat panel section 8PRO001-AUG1815

instructions 8 x 4 ft Proslat panel section 8PRO001-AUG1815 instructions 8 x 4 ft Proslat panel section 8PRO001-AUG1815 your box contains Tools required Stud finder 2 x 97,5 in J trims (2.49 m)* Snips 1 x 8 ft L trim (2.44 m) 8 ft Proslat panels (10 pcs) Level

More information

AUTOMATIC FOLDING DOOR

AUTOMATIC FOLDING DOOR AAADM American Association of Automatic Door Manufacturers AUTOMATIC FOLDING DOOR OWNER'S MANUAL Distributed by: Section Contents Page Caution 2 To Our Customers 3 Service Availability 3 Compliance with

More information

SECTION MOTOR CONTROL CENTER

SECTION MOTOR CONTROL CENTER SECTION 16445 MOTOR CONTROL CENTER PART 1 GENERAL 1.01 DESCRIPTION A. This section covers the contract item Motor Control Center (MCC). The contract item includes demolition and removal of existing MCC;

More information

Precison Manufacturing

Precison Manufacturing Pure Refined Precision Product Overview Iconic Purity Truly pure and refined sliding door hardware system that makes a statement in any application. Completely hidden fasteners add to the streamline aesthetics

More information

TRACK LED SCOREBOARD INSTRUCTION MANUAL REVISION DATE: PART#:

TRACK LED SCOREBOARD INSTRUCTION MANUAL REVISION DATE: PART#: TRACK LED SCOREBOARD INSTRUCTION MANUAL REVISION DATE: 11-17-08 PART#: 98-0015-02 SERVICE & CUSTOMER INFORMATION CUSTOMER MUST HAVE PART NUMBER WHEN ORDERING ITEMS THROUGH THE SERVICE DEPARTMENT. IF FURTHER

More information

UBC Technical Guidelines Division Edition Furnishings Page 1 of 1 INDEX

UBC Technical Guidelines Division Edition Furnishings Page 1 of 1 INDEX UBC Technical Guidelines Division 12 2018 Edition Furnishings Page 1 of 1 INDEX Section 12 00 00 Section 12 20 00 Section 12 30 00 Section 12 35 53 Furnishings Window Coverings and Blinds Fabricated Casework

More information

1. DEFINITIONS 2. ORDERS, PRICES AND FEES

1. DEFINITIONS 2. ORDERS, PRICES AND FEES Exhibit C GENERAL TERMS AND CONDITIONS - INTERNATIONAL The following are the Terms and Conditions under which TRANSCORE, LP, a Limited Partnership chartered in Delaware, United States of America or its

More information

SECTION TEMPORARY FACILITIES AND CONTROLS

SECTION TEMPORARY FACILITIES AND CONTROLS Montgomery County Public Schools Facilities DIVISION 1 - GENERAL REQUIREMENTS SECTION 01500 - TEMPORARY FACILITIES AND CONTROLS PART 1 - GENERAL 1.1 Summary: A. Provide temporary facilities and controls

More information

Capital Projects Group Gas Fired Warm Air Furnace Specification

Capital Projects Group Gas Fired Warm Air Furnace Specification Capital Projects Group Gas Fired Warm Air Furnace Specification Specification 23 54 16 Revision 1 Date: September 2018 Gas Fired Warm Air Furnace Specification Specification 23 54 16 Publication Date:

More information

This section applies to service areas and loading docks for new construction and major renovations.

This section applies to service areas and loading docks for new construction and major renovations. Basis of Design This section applies to service areas and loading docks for new construction and major renovations. Programming Minimum requirements: Defined custodial area, service area and loading docks

More information

Model 5000 Cargo Lift Installation and Operations Manual

Model 5000 Cargo Lift Installation and Operations Manual Model 5000 Cargo Lift Installation and Operations Manual Congratulations on the purchase of your new SpaceLift Products 5000 cargo lift system. Expect to receive many years of reliable service moving household

More information

AUTOMATIC FOLDING DOOR

AUTOMATIC FOLDING DOOR AAADM American Association of Automatic Door Manufacturers AUTOMATIC FOLDING DOOR OWNER'S MANUAL Distributed by: Section Contents Page Caution 2 To Our Customers 3 Service Availability 3 Compliance with

More information

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz Miniglaze/2 PORCELAIN STAINING AND GLAZING FURNACE Owner & Operator's Manual Model No: Voltage: 9490950 115V 50/60Hz 9490952 220V 50/60Hz DESCRIPTION PAGE Safety...2 Features...3 Furnace Description...4

More information

LIGHT COMMERCIAL LIMITEDWARRANTY

LIGHT COMMERCIAL LIMITEDWARRANTY Overview LIGHT COMMERCIAL LIMITEDWARRANTY 1. Scope of application... 2. Warranties... 1) Wear Warranty... 2) Structural Warranty... 3) Radiant-heated subfloor installation warranty... 4) Moisture warranty...

More information

System Specifications

System Specifications System Specifications Dimensions - Filter Assembly.........7.5 W x 3 D x 16.5 H - Storage Tank - Std......9 Diameter x 14 H - Medium..............11 Diameter x 14 H - Large................15.5 Diameter

More information

WIC/WICD/WICL/WICDL & WB/WSB Series. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE WIC-ICED COLD PAN 4-5/8" STANDARD DEPTH

WIC/WICD/WICL/WICDL & WB/WSB Series. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE WIC-ICED COLD PAN 4-5/8 STANDARD DEPTH WIC/WICD/WICL/WICDL & WB/WSB Series Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components

More information

Installation Manual. Retractable Ceiling Column Models 8301 & 8301PC

Installation Manual. Retractable Ceiling Column Models 8301 & 8301PC Retractable ceiling column Installation Manual Retractable Ceiling Column Models 8301 & 8301PC Overview The Retractable Ceiling Column is a convenient and cost-effective way of supplying medical gas and

More information

CFL Series User Manual

CFL Series User Manual CFL SERIES Continuous Level Transmitter CFL Series User Manual Quick Start Guide TM Please read this manual carefully before using product CFL Series Sensor Manual Heavy Duty Industrial Level Transmitter

More information

LIMITED LIGHT COMMERCIAL USE WARRANTY

LIMITED LIGHT COMMERCIAL USE WARRANTY LIMITED LIGHT COMMERCIAL USE WARRANTY 1. SCOPE OF APPLICATION This Light Commercial Limited use warranty is offered by us and is Worldwide applicable. This warranty applies to our water-resistant laminate

More information

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

3601 E. 34th St. Tucson, AZ USA Tel Fax Web: Equipment Type: Model: Electrical Requirements: Frequency: Manual Revision Date: Air Flow Sound Level Fume Hood FUME HOOD 110V 60 Hz February 15, 2018 1175-1470 cfm 65 dba Contents Warranty PAGE ii 1.0

More information

Inventory Details Report

Inventory Details Report page 1/ Surplus NC-001 -- Microwave Appliances 1 $20.00 NC-002 -- Large Fridge Appliances 1 $30.00 NC-003 -- Mini Refrigerator Appliances 1 $20.00 NC-008 -- Office Chairs w/o Arms Chairs 18 $25.00 NC-012

More information

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N Thermoelectric Coolers All Models INSTRUCTION MANUAL Rev. G 2016 Pentair Equipment Protection P/N 89072602 89072603 TABLE OF CONTENTS RECEIVING THE THERMOELECTRIC COOLER...3 HANDLING & TESTING THE THERMOELECTRIC

More information

INCLINATOR ELEVETTE. Planning Guide. CABLE DRUM 1000 lb. (454 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR

INCLINATOR ELEVETTE. Planning Guide. CABLE DRUM 1000 lb. (454 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR INCLINATOR ELEVETTE Planning Guide CABLE DRUM 1000 lb. (454 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR Introduction It started over 90 years ago with a passion to help an ailing friend access his multi-level

More information

Wellington Manor Series

Wellington Manor Series Wellington Manor Series Single-Section Homes titanhomesny.com 2 titanhomesny.com About us A home should say something about the people who live inside it. From contemporary to traditional, our homes will

More information

Royal Sovereign RSL 2701 Laminator

Royal Sovereign RSL 2701 Laminator Royal Sovereign RSL 2701 Laminator Instruction Manual Provided By http://www.mybinding.com http://www.mybindingblog.com TABLE OF CONTENTS Introduction -----------------------------------------------------------------------------------

More information

Partners in Mobile / Relocatable Diagnostic Solutions

Partners in Mobile / Relocatable Diagnostic Solutions Partners in Mobile / Relocatable Diagnostic Solutions WHY MOBILE? With a certified Smit mobile unit you will have the latest technological developments within reach. A state-of-the-art solution offering

More information

WALL SHELVES. Cleaning and Maintenance INSTRUCTION MANUAL

WALL SHELVES. Cleaning and Maintenance INSTRUCTION MANUAL INSTRUCTION MANUAL WALL SHELVES Cleaning and Maintenance Read and understand all of the instructions and safety information in this manual before operating this product. MAN-076 REV B 2018 MAC Medical,

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document No. 1800-59 MicroVac Portable Cleanroom Vacuum Cleaner Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave.

More information

MODEL NUMBER: 1419 SERIES

MODEL NUMBER: 1419 SERIES 1 PRODUCT DESCRIPTION Semi-Recessed Rectangular Vitreous China Lavatory with Overflow Semi Recessed 2" Above Counter 8" Spread Faucet Drilling Vitreous China High Gloss Ceramic Finish PRODUCT MEASUREMENTS

More information

E3X-DRT21/SRT21/CIF11

E3X-DRT21/SRT21/CIF11 for E3X-DA-N-series Fiber Amplifiers /SRT21/CIF11 CSM SRT21_CIF11_DS_E_3_2 Three New s for Fiber Amplifiers DeviceNet CompoBus/S RS-422 Note: Manufacture of the E3X-DA6-P will be discontinued in March

More information

$250 Capacity ChangeMaker Operator s Manual

$250 Capacity ChangeMaker Operator s Manual $250 Capacity ChangeMaker Operator s Manual Rev. 2017.11.17 1 INTRODUCTION Congratulations on the purchase of your new ChangeMaker. This ChangeMaker has been designed to give you many years of dependable

More information

Thermoelectric Cooler

Thermoelectric Cooler INSTRUCTION MANUAL Thermoelectric Cooler TE090624020, TE121024020, TE121048020, TE162024020, TE162048020, TE090624010, TE121024010, TE121048010, TE162024010, TE162048010, TE090624011, TE121024011, TE162024011

More information

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 14 - CONVEYING EQUIPMENT DESIGN STANDARDS SECTION

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 14 - CONVEYING EQUIPMENT DESIGN STANDARDS SECTION PART 1 - GENERAL 1.01 Elevator manufacturer to provide equipment and installation warranty and maintenance services for at least one year after acceptance. This requires routine monthly inspection, emergency

More information

SECTION TEMPORARY FACILITIES AND CONTROLS CONSTRUCTION MANAGER EDITION

SECTION TEMPORARY FACILITIES AND CONTROLS CONSTRUCTION MANAGER EDITION Montgomery County Public Schools Facilities DIVISION 1 - GENERAL REQUIREMENTS SECTION 01500 - TEMPORARY FACILITIES AND CONTROLS CONSTRUCTION MANAGER EDITION PART 1 - GENERAL 1.1 Summary: A. Provide temporary

More information

UNI BAR. user manual. ELATION UNI BAR user manual

UNI BAR. user manual. ELATION UNI BAR user manual UNI BAR user manual ELATION UNI BAR user manual 2016 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice.

More information

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS SHCM-27180 SHOWER COLUMN INSTALLATION INSTRUCTIONS IMPORTANT DreamLine TM reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical

More information

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual Original Instructions Installation, Operation & Maintenance Manual Sentry IC Indexing Cabinet Automatic Sampling Accessories S-AS-IOM-00462-2 11-17 Do not install, maintain, or operate this equipment without

More information

The Kodiak 3200 Seating System by Royal Stewart Ltd.:

The Kodiak 3200 Seating System by Royal Stewart Ltd.: The Kodiak 3200 Seating System by Royal Stewart Ltd.: PART 1 GENERAL 1.01 Summary A. Bleacher System shall be Series 3200 Platforms as manufactured by Royal Stewart Ltd., Winnipeg, Manitoba, in accordance

More information

4-Wire Buffer Amplifier. User Manual

4-Wire Buffer Amplifier. User Manual 4-Wire Buffer Amplifier User Manual 9350-7767-000 8/2003 2 Proprietary Notice The RTS product information and design disclosed herein were originated by and are the property of Telex Communications, Inc.

More information

4-PIECE SHOWER WITH E-Z Pin INSTALLATION

4-PIECE SHOWER WITH E-Z Pin INSTALLATION 4-PIECE SHOWER WITH E-Z Pin INSTALLATION Suggested Tools Please consult all local and state building codes and read the entire installation instructions prior to beginning the installation of this unit

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL IQ200TE and IQ300TE Thermoelectric Coolers OPERATION AND INSTALLATION MANUAL *** IMPORTANT *** PLEASE READ this manual and follow the instructions for safe and satisfactory installation and operation of

More information

TO THE TECHNICAL SPECIFICATION OF WORKS FOR DESIGN, PROCURMENT AND CONSTRUTION OF THE NATURAL GAS INTERCONNECTOR GREECE-BULGARIA (IGB PROJEC)

TO THE TECHNICAL SPECIFICATION OF WORKS FOR DESIGN, PROCURMENT AND CONSTRUTION OF THE NATURAL GAS INTERCONNECTOR GREECE-BULGARIA (IGB PROJEC) ATTACHMENT 16 TO THE TECHNICAL SPECIFICATION OF WORKS FOR DESIGN, PROCURMENT AND CONSTRUTION OF THE NATURAL GAS INTERCONNECTOR GREECE-BULGARIA (IGB PROJEC) OFFICES, FACILITIES AND VEHICLES FOR CONTRACTING

More information

Model HH Signal-Conditioner / Indicator

Model HH Signal-Conditioner / Indicator Model HH Signal-Conditioner / Indicator 2080 Arlingate Lane, Columbus, Ohio 43228 USA (614)850-5000 Sensotec, Inc. 2080 Arlingate Lane Columbus, Ohio 43228 USA Copyright 2002 by Sensotec, Inc. all rights

More information

10155 Toilet Compartments

10155 Toilet Compartments 10155 Toilet Compartments This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or

More information

PROPOSAL FOR MODEL: HP 2100X

PROPOSAL FOR MODEL: HP 2100X PROPOSAL FOR MODEL: HP 2100X Provided by: www.ptipackaging.com Toll Free 1-800-472-0067 or Contact Us Online .SIMPLY BETTER MODEL HP 2100X HEAVY DUTY TURNTABLE SEMI-AUTOMATIC STRETCH WRAP SYSTEM GENERAL

More information

AquaFlow Intl Inc. Automated Bulk Water Loading Stations. AquaVendor RFID Card Based System. System User Guide

AquaFlow Intl Inc. Automated Bulk Water Loading Stations. AquaVendor RFID Card Based System. System User Guide AquaFlow Intl Inc. Automated Bulk Water Loading Stations AquaVendor RFID Card Based System System User Guide Founded and Operated in Flagstaff, AZ USA Table of Contents Introduction. 3 System Overview.

More information

SECTION VEHICLE LIFTS. B. Section Basic Electrical Materials and Methods: Power and controls wiring.

SECTION VEHICLE LIFTS. B. Section Basic Electrical Materials and Methods: Power and controls wiring. SECTION 14450 VEHICLE LIFTS PART 1 GENERAL 1.1 SECTION INCLUDES A. Skylifts. 1.2 RELATED SECTIONS A. Section 03300 - Concrete: Footings and foundations. B. Section 16050 - Basic Electrical Materials and

More information

TITAN THERMOPLASTIC COOLER FLOOR REPLACEMENT. Master Installation Contractor. PO Box 1387 Cary, NC / fax

TITAN THERMOPLASTIC COOLER FLOOR REPLACEMENT. Master Installation Contractor. PO Box 1387 Cary, NC / fax D. Brock Industries Innovating solutions Our commitment is to continually bring to market the best Engineered flooring systems, custom cleaning equipment, specialized customizable chemicals and other engineered

More information

Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information

Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information Gobi Owner s Manual Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information 3 4 5 6 7 8 9 10 Introduction

More information

Plan Check No. A. GROUP M OCCUPANCIES. NOTE: General sales, display and office areas together with toilet rooms shall be made accessible. (1110B.1.

Plan Check No. A. GROUP M OCCUPANCIES. NOTE: General sales, display and office areas together with toilet rooms shall be made accessible. (1110B.1. Plan Check No. A. GROUP M OCCUPANCIES NOTE: General sales, display and office areas together with toilet rooms shall be made accessible. (1110B.1.1) 1. Sales employee workstations shall be located on accessible

More information

P1902 Installation Manual

P1902 Installation Manual P1902 Installation Manual Precision Lighting Controller P1902-JRev. 1.0 2010 Profile Systems, LLC 1000 E. 80 th Place Suite 777 South Merrillville, IN 46410 (800) 898-5483 www.profilesystems.com Revision

More information

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following: SECTION 10501 PERSONNEL DUTY LOCKERS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 specifications

More information

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL Monroe Electronics 100 Housel Ave Lyndonville NY 14098 phone 585-765-2254 fax 585-765-9330 monroe-electronics.com Printed in USA Copyright Monroe Electronics,

More information

Integrated Model IC-36FI Design Guide

Integrated Model IC-36FI Design Guide Integrated Model IC-36FI Design Guide REVISED 9 / 2015 Features and specifications are subject to change at any time without notice. Visit subzero.com/specs for the most up-to-date information. IMPORTANT

More information

4. CIRCULATION SERVICES 6,213 SF

4. CIRCULATION SERVICES 6,213 SF 4. CIRCULATION SERVICES 6,213 SF Subcomponents: a. Circulation Desk - Reserve Material b. Self Service c. Sorting Areas d. Interior Book Drop e. OPAC Terminals f. Circulation Workroom g. Circulation Services

More information

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628 User Manual English APC Step-Down Transformer Models: AP9626, AP9627, and AP9628 990-7820F 06/2006 Introduction Introduction The APC step-down transformers are used to convert a higher input voltage (208-200

More information

Wash Down Duty Non-Contact Sensor

Wash Down Duty Non-Contact Sensor Wash Down Duty Non-Contact Sensor Instruction Manual Models WDDC1-020/040/060/080/100 WDDC2-020/040/060/080/100 WDDV1-020/040/060/080/100 WDDV2-020/040/060/080/100 Table of Contents 1. General Description.....................................

More information

a u t o b a h n price list january 2018

a u t o b a h n price list january 2018 a u t o b a h n price list january 2018 terms and conditions Sales and Service Policy Guidelines detailing the operating policies and procedures of Bernhardt Design are provided in the Sales and Service

More information

Integrated Refrigeration Design Guide

Integrated Refrigeration Design Guide Integrated Refrigeration Design Guide Contents 3 Integrated Refrigeration 4 Specifications 8 Custom Panels 11 Full-Scale Template 13 Warranty Features and specifications are subject to change at any time

More information

Keysight 16380C Capacitance Standard Set

Keysight 16380C Capacitance Standard Set Keysight 16380C Capacitance Standard Set Operating Note Notices The information contained in this document is subject to change without notice. This document contains proprietary information that is

More information

Portalcast Block Cutting and Casting System. Quickly cut and cast a precision mold and mount the casting to a blocking tray.

Portalcast Block Cutting and Casting System. Quickly cut and cast a precision mold and mount the casting to a blocking tray. Portalcast Block Cutting and Casting System Quickly cut and cast a precision mold and mount the casting to a blocking tray. Portalcast Block Cutting and Casting System Hundreds of radiation therapy departments

More information

35.0 Sterile Supply Unit (SSU)

35.0 Sterile Supply Unit (SSU) 35.0 Sterile Supply Unit (SSU) 35.1 Introduction 35.1.1 General A Hospital must provide adequate facilities for cleaning, sterilisation and storage of equipment and instruments to ensure the care and safety

More information

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web:   IMPORTANT!!! 10810 W. LITTLE YORK RD. #130 - HOUSTON, TX 77041-4051 VOICE (713) 973-6905 - FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN

More information

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System.  January 2012 Version MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SCP Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description

More information

DS-520 Digital Indicator Operation Manual 73366

DS-520 Digital Indicator Operation Manual 73366 DS-520 Di gi tal Indi cator Operation Manual 73366 SECTION DS-520 SERIES OPERATING MANUAL INDEX PAGE NUMBER 1.0 GENERAL 2-3 1.1. Features 2 1.2. Keyboard & Display Layout 2 1.3. Key Switch Information

More information

Model 292A. Surface Resistance Test Kit. Instruction Manual

Model 292A. Surface Resistance Test Kit. Instruction Manual Model 292A Surface Resistance Test Kit Instruction Manual Printed in USA Copyright 2016 Monroe Electronics, Inc. Specifications subject to change without notice. P/N 0340198 292A/100 04122016 100 Housel

More information

SECTION 5 E-Treat Water Conditioning Systems

SECTION 5 E-Treat Water Conditioning Systems SECTION 5 E-Treat Water Conditioning Systems WaTEr QualITy PrOduCTS Catalog 10 Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. Watts

More information

QUOTE PROPOSAL. OverheadCraneKit.com. Presented by: Date: Quote ID: E1000. OverheadCraneKit.com

QUOTE PROPOSAL. OverheadCraneKit.com. Presented by: Date: Quote ID: E1000. OverheadCraneKit.com OverheadCraneKit.com QUOTE PROPOSAL Presented by: OverheadCraneKit.com 800-509-6131 info@overheadcranekit.com Date: 04/04/2008 Quote ID: E1000 An authorized distributor of: OverheadCraneKit.com (800) 509-6131

More information

OPERATOR S MANUAL Model 56A Prefeed / Dereeler

OPERATOR S MANUAL Model 56A Prefeed / Dereeler 110 Fairgrounds Drive P.O. Box 188 Manlius, NY 13104-0188 USA 315.682.9176 FAX: 315.682.9160 OPERATOR S MANUAL Model 56A Prefeed / Dereeler PRODUCTION WIRE PROCESSING EQUIPMENT Website: www.carpentermfg.com

More information

Audacity Flooring LIMITED COMMERCIAL USE WARRANTY

Audacity Flooring LIMITED COMMERCIAL USE WARRANTY Audacity Flooring LIMITED COMMERCIAL USE WARRANTY 1. SCOPE OF APPLICATION This Commercial use warranty is offered by us and is Worldwide applicable. This warranty applies to our water-resistant laminate

More information

SECTION PROJECT CLOSEOUT

SECTION PROJECT CLOSEOUT PART 1 - GENERAL 1.01 SCOPE OF WORK A. This Section specifies administrative and procedural requirements for project closeout, including but not limited to: 1. Close-out procedures 2. Final cleaning 3.

More information

PAGODA SERIES OPERATOR'S MANUAL

PAGODA SERIES OPERATOR'S MANUAL Pagoda Series Packaged Blowers Keep This Manual With Pagoda Find additional information on this model at kooltronic.com, or use the Technical Documents QR code below. Technical Documents PAGODA SERIES

More information

Dynatronics Parallel Bars

Dynatronics Parallel Bars Dynatronics Parallel Bars Operation & Service Manual For: Electric Height & Width Parallel Bars Electric Height Parallel Bars Platform Parallel Bars Folding Parallel Bars Dynatronics Corporation Dynatronics

More information