The Use of LC-MS in Systematic Toxicology Analysis

Size: px
Start display at page:

Download "The Use of LC-MS in Systematic Toxicology Analysis"

Transcription

1 CAT Meeting Phoenix, AZ June 8, 7 Presentation outline Methods used in Systematic Toxicology Analysis The Use of LC-MS in Systematic Toxicology Analysis LC/MS approach ChromaLynx software Chromatogram deconvolution Library LC/MS vs. GC/MS LC/MS vs. UV detection Jan Bohuslavek,, Ph.D. Waters Corporation Summary 7 Waters Corporation 7 Waters Corporation Forensic laboratory: analytical approaches The known (or suspected toxic analyte) Class identified by screening assay Adverse effects to known medication History of misuse of prescription medication or illicit drugs Evidence at scene Analytical approach: Targeted analysis by LC-MS/MS The unknown Typical situation: ER, forensic, crime labs illicit compounds? Misuse of prescribed drugs? r basically anything else! LC-MS and ChromaLynx software for Systematic Toxicological Analysis Analytical approach: Screen by LC-MS 7 Waters Corporation 3 7 Waters Corporation

2 Techniques for Toxicology Screening Different Approaches LC-MS & ChromaLynx Approach Traditional screening methods Immunoassays Screening & quantitation Cross reactivity, cost ot available for all drugs LC/UV Identification in complex mixtures UV libraries exist Sensitivity/specificity GC/MS ( gold standard ) Relatively inexpensive Multiple libraries exist Derivatization, laborious ot suitable for ALL compounds Current method combines LC-MS with searchable database based on in-source CID Benefits of using LC large number of samples can be analysed by LC o derivatization Benefits of multiple spectral identification criteria Data matched to a searchable and appendable library 7 Waters Corporation 5 7 Waters Corporation 6 Toxicology Screening & LC/MS Information available from one LC/MS Analysis Mass Spectra Database & Library Building: LC/MS Experimental Conditions HPLC PDA MS Retention (1) UV Absorption Information () Parent Ion (3) Fragment Ions (4-15!) Instrumentation A single or triple quadrupole mass spectrometer, LC, autosampler RIVTRIL Clonazepam 7 Clonazepam Clonazepam : Diode Array.75e7 4: Scan ES+ 1.5e9 : Scan ES+ 4.43e8 Clonazepam 1: Scan ES e RIVTRIL Clonazepam 98 (15.57) Cm (95:93-91:914) e5 31 nm RIVTRIL Clonazepam 67 (15.59) Clonazepam 67 (15.557) 7 6: Scan ES+ 1.66e Clonazepam 67 (15.549) : Scan ES e : Scan ES- 1.36e m/z Waters Corporation 7 Liquid Chromatography Generic gradient based on water/acetonitrile mobile phase with ammonium formate and formic acid (~ 3 min run).1 mm id - 3.5µm XTerra C 18 MS 35 C with pre-column LC/MS allows collection of multi-spectral data Pos/ mass spectra recorded at different cone voltages ne analyte can be characterized by up to 1 mass spectra plus retention time 7 Waters Corporation 8

3 LC/MS and In-Source CID: Generation of Fragments LC/MS and In-Source CID: Generation of Fragments & Library Concept Extractor Ions formed in the atmospheric region are sampled through the sample cone. [MH] Volts 5 o Fragmentation Cl H H 356 [M-H] Volts +3 Volts MW: 355 CAS# CHCl3 (toxml1884) Amodiaquine 15V] -3 Volts Sample Cone These ions can be accelerated by applying a voltage gradient between the sample cone and the extractor cone. +45 Volts +6 Volts Exhaustive Structural Information -45 Volts -6 Volts These ions gaining speed will hit residual neutral molecules in that region and will gain internal energy and eventually fragment into specific ions. +75 Volts +9 Volts Cl H H -75 Volts -9 Volts F MW: 355 CAS# CHCl3 (toxml1884) Amodiaquine 9V] Total Fragmentation F - 7 Waters Corporation 9 7 Waters Corporation 1 In-Source CID - LC/MS Library: Some Examples In-Source CID - LC/MS Library: Some Examples TIMLL Free Base C 13 H S MW (ominal 316) CAS# S CH 3 ESI+@9V ESI+@75V ESI+@6V ESI+@45V 61 BUTBARBITAL C 1 H MW 1.5 (ominal 1) CAS# H 3 C H H ESI-@9V ESI-@75V ESI-@6V ESI-@45V H Results in getting 6 specific m/z values with different fragmentation patterns for each voltage value: 317 [M+H] +, 61,44,188,144 &113 H CH 3 CH ESI+@3V 317 ESI+@15V m/z H 3 C Barbiturates give a good response to ative ESI. The m/z 155 is generally observed for most of the barbiturates m/z ESI-@3V ESI-@15V 7 Waters Corporation 11 7 Waters Corporation 1

4 In-Source CID - LC/MS Library: Some Examples In-Source CID - LC/MS Library: Some Examples ITRAZEPAM C 15 H MW 81.7 (ominal 81) CAS# H 158 ESI+@9V ESI+@7V ESI+@5V 8 Acepromazine & aceprometazine UV versus MS Same molecular formula Similar retention times Same UV spectra - + Some molecules may give a good response in both positive & ative ESI thus allowing unambiguous identification. 83 ESI-@9V ESI-@7V ESI-@5V m/z Waters Corporation 13 Identical mass 15 & 3 V Differences appear around 45 V Differentiation possible The probability that two compounds have the same mass, same fragmentation patterns over 6 different CV s in both positive and ative ion polarities, and elute at the same retention time is very low! 7 Waters Corporation 14 Toxicology Screening & LC/MS Analysis of the Unknown :: Challenges Chromatogram Examination and Peak Detection Do I really see what I should see? Challenges: Complicated chromatograms - Minor peaks - Hidden, co-eluting peaks Identification of the analytes - Correct mass spectrum for each component - Retention time used in library search in addition to spectra 7 Waters Corporation : Scan ES e : Scan ES e e : Scan ES e : Scan ES e : Scan ES e : Scan ES e : Scan ES e9 Area peaks? At least 5! : Scan ES e This area represents only 1 min out of the 5 minute chromatogram of one of the many functions! Waters Corporation 16

5 Chromatogram Examination and Peak Detection Mass Spectra Extraction ChromaLynx for Toxicological Screening : Scan ES : Scan ES e9 3.3e Area Apparent peak RT 14.7 min Mixture Apparent peak RT min Mixture ,, , m/z Peak #5 RT Peak #4 RT 14.1 min m/z Waters 35 Corporation Peak #3 RT min Peak # RT 13.7 min Peak #1 RT min Especially developed for screening using Full scan MS spectral libraries Data processing software based on chromatogram deconvolution techniques - Chromatogram examination - Component detection - Candidate proposal 7 Waters Corporation 18 ChromaLynx for Toxicological Screening Chromatogram Examination : How does it work? Virtually, every scan from each function can be examined and extracted ion chromatograms are generated for the most intense ions. 4.47e Automated Mass Spectrum scan 37 for Function (13.854) 5: Scan ES e m/z e e e e e e e Waters Corporation 19 ChromaLynx for Toxicological Screening Component Detection and Mass Spectrum Extraction Peaks in extracted ion chromatograms should be within a limit in terms of scan position (retention time) to be considered as a sole peak. Mass spectrum is then extracted. Scan e e e e e e e e component: comprising ions m/z 8, 65,, 146, Waters Corporation

6 ChromaLynx Library The library is in IST format Contains hundreds of compounds and metabolites Easily appendable by users Contains multiple entries for every compound (different cone voltage and polarity) Each entry contains: Parent mass Fragment masses Retention time Fragment abundance 7 Waters Corporation 1 7 Waters Corporation ChromaLynx Data Examples Analytical Equipment and Instrumentation Waters ZQ (Single Quadrupole MS) or Quattro Micro (MS/MS) Alliance 695 Liquid chromatography system HPLC Separation Method Waters XTerra TM MS C18, 3.5 µm,.1mm id x 15 mm (1 mm for precolumn) Mobile Phase based on Water/Acetonitrile with 5 mm Ammonium Formate MS perating Conditions Function 1: Full Scan - egative ESI from to 65 3 Volts Functions to 7: Full Scan - Positive ESI from to to 9 Volts 7 Waters Corporation 3 7 Waters Corporation 4

7 Example: : Strychnine poisoning (From AIT Laboratories) A Example of Strychnine Poisoning Unexplained death Vomit was found at the scene The symptoms were indicative of strychnine poisoning A sample of vomit was submitted for screening Liquid-liquid extraction of the sample was performed, analyzed Fentanyl was used as an internal standard 7 Waters Corporation 5 7 Waters Corporation 6 Example: Polyintoxication - Suicide attempt by massive ingestion of various medications A 65 years old woman was brought to an emergency department. Said she had taken different pills from among her regular medications. Urine samples were analyzed. Toxicologists were looking for molecules coming from the regular treatment and unexpected substances. The known medications taken by the patient were: Thanks for your attention Questions? 7 Waters Corporation 7 7 Waters Corporation 8

8 A Example of Polyintoxication - Suicide attempt by massive ingestion of various medication Results All expected molecules were found except Tramadol Additional molecules were identified as the main cause of the intoxication: Meprobamate - Mepronizine Aceprometazine - Mepronizine Bromazepam 7 Waters Corporation 9 7 Waters Corporation 3 LC/MS vs. GC/MS Evaluation of an LC/MS Method to Screen for Drugs in Postmortem Whole Blood Specimens 15 post-mortem whole blood specimens were analyzed. In many cases, the GC/MS and LC/MS results were comparable (see examples in Table 1). In the majority of cases, the LC/MS method was able to identify more analytes compared to the GC/MS method (see examples in Table ). Kevin Shanks¹*, Tim Dahn¹,, Andrea R. Terrell, Ph.D.¹,, and Jan Bohuslavek,, Ph.D.² ¹AIT Laboratories, Indianapolis, I, ²Waters Corporation, Milford, MA, USA 7 Waters Corporation 7 Waters Corporation 3

9 Sample umber Case Studies: Table 1 and GC/MS Results Amitriptyline ortriptyline lanzapine Paroxetine Bupropion Desmethylsertraline Lamotrigine Chlorpromazine LC/MS Results Amitriptyline ortriptyline lanzapine Paroxetine Bupropion Lamotrigine Chlorpromazine Confirmed Results Amitriptyline ortriptyline lanzapine Paroxetine Bupropion Desmethylsertraline Lamotrigine Chlorpromazine orsertraline 7 Waters Corporation 33 Sample umber GC/MS Results egative egative Acetaminophen Promethazine Chlorpheniramine Dextromethorphan egative LC/MS Results Fentanyl Cocaine ordiazepam Acetaminophen Propoxyphene Promethazine ordiazepam Citalopram Desmethylcitalopram Chlorpheniramine Dextromethorphan Alprazolam Amiodarone Desmethylamiodarone Confirmed Results Fentanyl Cocaine ordiazepam Acetaminophen Propoxyphene Promethazine ordiazepam Chlorpheniramine Dextromethorphan Alprazolam 7 Waters Corporation 34 Conclusion LC/MS vs. LC (Bio Rad s REMEDi) The ChromaLynx software library is thorough. The software is very easy to learn and use. The deconvolution process is very effective. The library is easily appendable by the analyst. The LC/MS method identified more compounds than the GC/MS method. In comparison to the GC/MS method, the LC/MS method is more efficient at identifying polar analytes. A comparison study performed at the Clinical Labs of Hawaii 7 Waters Corporation 35 7 Waters Corporation 36

10 Sample REMEDi LC/MS W11637 W11639 W11641 F5611 F5615 F61817 Study: F618 H samples analyzed using both LC/MS approach and REMEDi W1966 W19658 M6835 X4863 X48637 X48639 Results: W6389 S441 7 samples produced ative results using both methods W6395 F1739 W samples produced identical positive results H44533 W samples showed more confirmed positive hits using LC/MS F36518 S1714 F36517 W5886 M Waters Corporation 37 M Waters Corporation 38 Samples with comparable results Samples in which LC/MS approach identified more analytes than REMEDi Sample T4743 T31 F3415 T797 T4718 F5616 T4718 H395 T31 H948 REMEDi Venlafaxine Benzoylecgonine Benzoylecgonine Ranitidine xycodone Propoxyphene Codeine Alprazolam LC/MS Venlafaxine Benzoylecgonine Benzoylecgonine Ranitidine xycodone Propoxyphene Codeine Alprazolam Sample H18493 W18614 X48641 W19675 T4743 W45 H741 H86 REMEDi LC/MS Dextromoramide Dextromoramide Dextromoramide Dextromoramide, Benzoylecgonine 7 Waters Corporation 39 7 Waters Corporation 4

11 ChromaLynx for Toxicological Screening: Summary Acknowledgements From a technical point of view LC/MS constitutes an excellent additional tool for Toxicological Screening The library contains exhaustive structural information for each compound ChromaLynx utilises an efficient data processing which: - Avoids the risk of missing small or co-eluting peaks - Allows to detect small amount of compounds in Full Scan - Includes examination of multiple functions - Includes retention time control T. Dahn AIT Laboratories, Indianapolis, I Dr. C. Wong and C. issen Clinical Laboratories of Hawaii Potentially usable on any Waters-Micromass Quadrupole-Based Instrument 7 Waters Corporation 41 7 Waters Corporation 4 Thanks for your attention Questions? 7 Waters Corporation 43

Using accurate mass LC/MS/MS in forensic toxicology screening

Using accurate mass LC/MS/MS in forensic toxicology screening Using accurate mass LC/MS/MS in forensic toxicology screening Dr Simon Elliott Consultant Forensic Toxicologist (ROAR) Forensics Ltd Malvern Hills Science Park, Geraldine Rd, Malvern, Worcestershire, WR14

More information

LC/MS. Why is it the fastest growing analytical technique?

LC/MS. Why is it the fastest growing analytical technique? LC/MS Why is it the fastest growing analytical technique? Discussion topics Evolution of LC/MS Advantages of API Why should I use LC/MS? LC/MS markets Evolution of LC/MS interfaces 1970s to Present Moving

More information

An Automated Processing of LC/MS Data for the Detection of Drug Impurities and Degradants in the Pharmaceutical Industry

An Automated Processing of LC/MS Data for the Detection of Drug Impurities and Degradants in the Pharmaceutical Industry APPLICATIO OTE 247 An Automated Processing of LC/MS Data for the Detection of Drug Impurities and Degradants in the Pharmaceutical Industry Soraya Monté 1, Jose Castro-Perez 2 and Steve Preece 2 1 Analytical

More information

BIOANALYTICAL STRATEGY FOR IN VITRO METABOLITE SCREENING WITH EXACT MASS USING THE Q-Tof micro. Jose M. Castro-Perez 1, Carina Leandersson 2

BIOANALYTICAL STRATEGY FOR IN VITRO METABOLITE SCREENING WITH EXACT MASS USING THE Q-Tof micro. Jose M. Castro-Perez 1, Carina Leandersson 2 In metabolism studies, it is vital to understand how a particular drug is absorbed, distributed, metabolised, and eliminated by the body. Metabolite identification is a very important part of the drug

More information

Pharmaceutical LC/MS Solutions from Agilent Technologies

Pharmaceutical LC/MS Solutions from Agilent Technologies Pharmaceutical LC/MS Solutions from Agilent Technologies Application Compendium Overview LC/MS plays a key role in the drug discovery and drug development process. Since the introduction of electrospray

More information

Single-Injection Screening of 664 Forensic Toxicology Compounds on a SCIEX X500R QTOF System

Single-Injection Screening of 664 Forensic Toxicology Compounds on a SCIEX X500R QTOF System vmethod Application for Forensics Toxicology Single-Injection Screening of 664 Forensic Toxicology Compounds on a SCIEX X500R QTOF System Single-Injection Screening of 664 Forensic Toxicology Compounds

More information

Thermo Scientific TSQ Quantum Access MAX

Thermo Scientific TSQ Quantum Access MAX www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Scientific TSQ Quantum Access MAX UNSURPASSED PRICE TO PERFORMANCE Superior

More information

ortho/meta/para-fluorofuranylfentanyl

ortho/meta/para-fluorofuranylfentanyl ortho/meta/para-fluorofuranylfentanyl Sample Type: Biological Fluid Latest Revision: January 23, 2019 Date of Report: January 23, 2019 1. GENERAL INFORMATION IUPAC Name: InChI String: CFR: CAS# Synonyms:

More information

Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics

Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics Application Note Small Molecule Pharmaceuticals Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics Avoiding Matrix Effects Increasing Detection Sensitivity Authors Jonas Dinser Daiichi-Sankyo Europe

More information

Tabisam Khan 1, David R. Little 1, Liyu Yang 2, Jiwen Chen 2, Parya Nouri 2, Samy Tadros 2, Patrick J. Rudewicz 2

Tabisam Khan 1, David R. Little 1, Liyu Yang 2, Jiwen Chen 2, Parya Nouri 2, Samy Tadros 2, Patrick J. Rudewicz 2 AIMS High throughput bioanalysis plays a central role in the drug discovery and development process. The resulting data are used to determine a drug candidate's pharmacokinetic parameters that are crucial

More information

APPLICATION NOTE. Abstract. Introduction

APPLICATION NOTE. Abstract. Introduction APPLICATION NOTE Automated Sample Preparation for the Monitoring of Pharmaceutical and Illicit Drugs by LC-MS/MS SCIEX Triple Quad 4500 LC/MS/MS system and Beckman Coulter Biomek 4000 Workstation Lekh

More information

Automated Sample Preparation for the Monitoring of Pharmaceutical and Illicit Drugs by LC-MS/MS

Automated Sample Preparation for the Monitoring of Pharmaceutical and Illicit Drugs by LC-MS/MS Automated Sample Preparation for the Monitoring of Pharmaceutical and Illicit Drugs by LC-MS/MS SCIEX Triple Quad 4500 LC/MS/MS system and Beckman Coulter Biomek 4000 Workstation Lekh Sharma 1, Michael

More information

Applications of GC-MS-MS and LC-Ion Trap MS-MS in Postmortem Forensic Toxicology

Applications of GC-MS-MS and LC-Ion Trap MS-MS in Postmortem Forensic Toxicology An Executive Summary Applications of GC-MS-MS and LC-Ion Trap MS-MS in Postmortem Forensic Toxicology Joe Kahl Forensic Toxicologist Elisa Shoff Forensic Toxicologist George Hime Assistant Director Introduction

More information

Increased Throughput in the Determination of PPCPs in Water Using Optimized MS Cycle Times in a High Sensitivity UHPLC-Triple Quadrupole System

Increased Throughput in the Determination of PPCPs in Water Using Optimized MS Cycle Times in a High Sensitivity UHPLC-Triple Quadrupole System Increased Throughput in the Determination of PPCPs in Water Using Optimized MS Cycle Times in a High Sensitivity UHPLC-Triple Quadrupole System Application Note Environmental Authors Behrooz Zekavat, Thomas

More information

A Generic Approach to the Extraction of Multi-functional Drugs using Mixed-mode SPE with LC-MS/MS Analysis

A Generic Approach to the Extraction of Multi-functional Drugs using Mixed-mode SPE with LC-MS/MS Analysis A Generic Approach to the Extraction of Multi-functional Drugs using Mixed-mode SPE with LC-MS/MS Analysis Matthew Cleeve, Scott Merriman, Lee Williams, Steve Jordan, Richard Calverley, Joanna Smith &

More information

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System Heart-cut 2D-LC/M approach for pharmaceutical impurity identification using an Agilent 640 Q-TF LC/M ystem Application ote Pharmaceuticals Author iji Joseph Agilent Technologies, Inc. Bangalore, India

More information

Agilent 6400 Series Triple Quadrupole LC/MS Systems SUPERIOR SENSITIVITY WITH EASY UPGRADEABILITY

Agilent 6400 Series Triple Quadrupole LC/MS Systems SUPERIOR SENSITIVITY WITH EASY UPGRADEABILITY Agilent 6400 Series Triple Quadrupole LC/MS Systems SUPERIOR SENSITIVITY WITH EASY UPGRADEABILITY AGILENT 6400 SERIES TRIPLE QUADRUPOLE LC/MS SYSTEMS THE AGILENT 6400 SERIES TRIPLE QUADRUPOLE SYSTEMS AN

More information

TechnicalNOTE METABOLYNX EXACT MASS DEFECT FILTER: RAPIDLY DISCRIMINATE BETWEEN TRUE METABOLITES AND FALSE POSITIVES INTRODUCTION

TechnicalNOTE METABOLYNX EXACT MASS DEFECT FILTER: RAPIDLY DISCRIMINATE BETWEEN TRUE METABOLITES AND FALSE POSITIVES INTRODUCTION METABOLYNX EXACT MASS DEFECT FILTER: RAPIDLY DISCRIMINATE BETWEEN TRUE METABOLITES AND FALSE POSITIVES Jose M. Castro-Perez 1, Jane Kirby 1, Laurent Leclercq 2, Claude Delatour 2, Jean-Michel Mineur 2,

More information

for water and beverage analysis

for water and beverage analysis Thermo Scientific EQuan MAX Plus Systems Automated, high-throughput LC-MS solutions for water and beverage analysis Pesticides Pharmaceuticals Personal care products Endocrine disruptors Perfluorinated

More information

Application Note. Authors. Abstract. Ravindra Gudihal Agilent Technologies India Pvt. Ltd. Bangalore India

Application Note. Authors. Abstract. Ravindra Gudihal Agilent Technologies India Pvt. Ltd. Bangalore India Characterization of bacteriophage derived anti-staphylococcal protein (P28) from production to purification using Agilent HPLC-Chip Q-TOF LC/MS system Application Note Authors Ravindra Gudihal Agilent

More information

Genotoxicity is the property of a compound

Genotoxicity is the property of a compound Impurities Analysis in Pharmaceuticals: Genotoxicity is the property of a compound known to have irreversible effects on the structure and functionality of the DNA in cells and cause DNA loss, DNA replication

More information

A Novel Screening Method for Anthropogenic Sewage Pollutants in Waste Water, Ground Water and Drinking Water Samples by LC HRAM Analysis

A Novel Screening Method for Anthropogenic Sewage Pollutants in Waste Water, Ground Water and Drinking Water Samples by LC HRAM Analysis A Novel Screening Method for Anthropogenic Sewage Pollutants in Waste Water, Ground Water and Drinking Water Samples by LC HRAM Analysis Sebastian Westrup, Nick Duczak, and Michal Godula Thermo Fisher

More information

Introduction. Benefits of the SWATH Acquisition Workflow for Metabolomics Applications

Introduction. Benefits of the SWATH Acquisition Workflow for Metabolomics Applications SWATH Acquisition Improves Metabolite Coverage over Traditional Data Dependent Techniques for Untargeted Metabolomics A Data Independent Acquisition Technique Employed on the TripleTOF 6600 System Zuzana

More information

Metabolite ID. Introduction

Metabolite ID. Introduction Metabolite ID Introduction Drug metabolism plays an increasingly important role in the drug discovery and development process. For the early discovery phase, investigating drug metabolism is intended to

More information

Professional Panel Screen by LC/MS/MS. Andrew J. Fischinger Ph.D., MT(ASCP) & Lesli Joseph B.S. Norchem Drug Testing, Flagstaff, AZ

Professional Panel Screen by LC/MS/MS. Andrew J. Fischinger Ph.D., MT(ASCP) & Lesli Joseph B.S. Norchem Drug Testing, Flagstaff, AZ Professional Panel Screen by LC/MS/MS Andrew J. Fischinger Ph.D., MT(ASCP) & Lesli Joseph B.S. Norchem Drug Testing, Flagstaff, AZ LC/MS/MS GC/MS 1200L LC/MS & LC/MS/MS ProStar Binary 210 Solvent Delivery

More information

The Future of Reimbursement for Lab Developed Mass Spec Assays

The Future of Reimbursement for Lab Developed Mass Spec Assays The Future of Reimbursement for Lab Developed Mass Spec Assays Charles Root, PhD CodeMap, LLC Schaumberg, IL AACC/MSSS Mass Spectrometry and Separation Sciences for Lab Medicine Oct 1 2, 2015 1 The Future

More information

Using HRAM Survey Analysis Combined with Rapid MS2 Data to Develop a Fragmentation Based Detection Workflow for Structure ID Acquisition

Using HRAM Survey Analysis Combined with Rapid MS2 Data to Develop a Fragmentation Based Detection Workflow for Structure ID Acquisition Using HRAM Survey Analysis Combined with Rapid MS Data to Develop a Fragmentation Based Detection Workflow for Structure ID Acquisition Tim Stratton, 1 Caroline Ding, 1 Christoph Henrich, Hans Grensemann,

More information

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions Screening and Confirmation Chemical Analysis Solution Unit November, 2009 Page 1 Agilent s New 6540 Ultra High

More information

Illicit Drug Analysis in Urine Using 2D LC-MS/MS for Forensic Toxicology

Illicit Drug Analysis in Urine Using 2D LC-MS/MS for Forensic Toxicology Claude Mallet 1 and Sabra Botch-Jones 2 1 Waters Corporation, Milford, MA, USA 2 Boston University School of Medicine, Boston, MA, USA APPLICATION BENEFITS Fast extraction protocol (2 min) 1 ppt detection

More information

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF Application Note Author David L. Wong Agilent Technologies, Inc. Santa Clara, CA, USA Introduction Monoclonal

More information

Title: Non-absorbable apple procyanidins prevent obesity associated with gut microbial

Title: Non-absorbable apple procyanidins prevent obesity associated with gut microbial 1 2 3 SUPPORTING INFORMATION Title: Non-absorbable apple procyanidins prevent obesity associated with gut microbial and metabolomic changes 4 5 6 Authors: Saeko Masumoto, 1 Akari Terao, 2 Yuji Yamamoto,

More information

Characterization of a fusion protein under native and denaturing conditions with maxis II

Characterization of a fusion protein under native and denaturing conditions with maxis II Characterization of a fusion protein under native and denaturing conditions with maxis II Abstract The maxis II UHR-QTOF was used to characterize key attributes of a fusion protein in its native conformation

More information

ProMass HR Applications!

ProMass HR Applications! ProMass HR Applications! ProMass HR Features Ø ProMass HR includes features for high resolution data processing. Ø ProMass HR includes the standard ProMass deconvolution algorithm as well as the full Positive

More information

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 641 Triple Quadrupole LC/MS Application Note Environmental Author Toni Hall Wessex Water Bath, UK Abstract A method for the

More information

Key Words Pesticides analysis, food safety, TSQ Endura, TraceFinder, MRL, tsrm, residue analysis

Key Words Pesticides analysis, food safety, TSQ Endura, TraceFinder, MRL, tsrm, residue analysis Increased Productivity in Pesticide Residue nalysis Quantifying 440 Pesticides Following China GB 2763-2014: The Pesticide Explorer Collection Standard Quantitation Zeming Wu 1, Charles T. Yang 2, Zheng

More information

Agilent 6000 Series LC/MS Solutions. Confidence in Quantitative and Qualitative Analysis

Agilent 6000 Series LC/MS Solutions. Confidence in Quantitative and Qualitative Analysis Agilent 6000 Series LC/MS Solutions Confidence in Quantitative and Qualitative Analysis Agilent 6000 Series LC/MS Solutions SOLUTIONS THAT SET THE STANDARD Your work with Agilent instruments benefits from

More information

DRUG DISCOVERY & 2 September 2010

DRUG DISCOVERY & 2 September 2010 LC-MS/MS QUANTITATION IN DRUG DISCOVERY & DEVELOPMENT Ludmila Alexandrova 2 September 2010 1 For personal use only. Please do not reuse or reproduce without the author s permission. 2 Presentation Outline

More information

How discovery activities can influence metabolic profiling in the regulatory space? C. DELATOUR EBF, 25 th September 2015

How discovery activities can influence metabolic profiling in the regulatory space? C. DELATOUR EBF, 25 th September 2015 How discovery activities can influence metabolic profiling in the regulatory space? C. DELATOUR EBF, 25 th September 2015 Outline 2 ן Background - Objectives - Shift in Workflow - Metabolite in safety

More information

A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS

A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS Application Note PROTEOMICS METABOLOMICS GENOMICS INFORMATICS GLYILEVALCYSGLUGLNALASERLEUASPARG CYSVALLYSPROLYSPHETYRTHRLEUHISLYS A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery

More information

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use Liquid Chromatograph Liquid Chromatograph Mass Spectrometer CL Series for In Vitro Diagnostic Use Consistency. Performance. Reliability. Shimadzu s CL Series LC, LC-MS, and LC-MS/MS for in vitro diagnostic

More information

Analysis of Glyphosate and AMPA in Environmental Water Samples by Ion Chromatography and On-Line Mass Spectrometry with Minimal Sample Preparation

Analysis of Glyphosate and AMPA in Environmental Water Samples by Ion Chromatography and On-Line Mass Spectrometry with Minimal Sample Preparation Analysis of Glyphosate and AMPA in Environmental Water Samples by Ion Chromatography and On-Line Mass Spectrometry with Minimal Sample Preparation Cees Bruggink, Frans Schoutsen Thermo Fisher Scientific,

More information

Clearly better LC/MS solutions

Clearly better LC/MS solutions Agilent 6000 Series LC/MS Clearly better LC/MS solutions Our measure is your success. products applications soft ware services Agilent: the clearly better choice for qualitative and quantitative LC/MS.

More information

faster, confident more path to all the information in your samples. Agilent MassHunter Workstation Software Our measure is your success.

faster, confident more path to all the information in your samples. Agilent MassHunter Workstation Software Our measure is your success. Agilent MassHunter Workstation Software faster, A confident more path to all the information in your samples. Our measure is your success. products applications soft ware services MassHunter Workstation

More information

About HFL. Markets & services. Markets & services. Qualitative MS: Pharmaceutical Applications. Regulatory Framework

About HFL. Markets & services. Markets & services. Qualitative MS: Pharmaceutical Applications. Regulatory Framework Certainty of Identification in Pharmaceutical and Forensic Mass Spectrometry Phil Teale, HFL Ltd. About HFL The only laboratory in the world engaged in sports doping control & contract research Long heritage

More information

timstof Pro with PASEF and Evosep One: Maximizing throughput, robustness and analytical depth for shotgun proteomics

timstof Pro with PASEF and Evosep One: Maximizing throughput, robustness and analytical depth for shotgun proteomics timstof Pro with PASEF and Evosep One: Maximizing throughput, robustness and analytical depth for shotgun proteomics The timstof Pro powered by PASEF enables sequencing speed of > 2 Hz, high sensitivity

More information

Ligand Binding Mass Spectrometric Immunoassay (LB-MSIA ) Workflow with Deglycosylation for Therapeutic Antibodies

Ligand Binding Mass Spectrometric Immunoassay (LB-MSIA ) Workflow with Deglycosylation for Therapeutic Antibodies Ligand Binding Mass Spectrometric Immunoassay (LB-MSIA ) Workflow with Deglycosylation for Therapeutic Antibodies Kwasi Antwi, Amanda Ribar, Urban A. Kiernan, and Eric E. Niederkofler, Thermo Fisher Scientific,

More information

Thermo Scientific PAiNACEA Suite of Solutions

Thermo Scientific PAiNACEA Suite of Solutions m a s s s p e c t r o m e t r y Thermo Scientific PAiNACEA Suite of Solutions LC-MS Solutions for Pain Management Analysis in Forensic Toxicology Laboratories Benzodiazepines Opiates Synthetic Opioids

More information

Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector

Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector Application Note Clinical Research Author Patrick Cronan Agilent Technologies,

More information

impact Innovation with Integrity Maximum Impact Definitive Answers UHR-TOF MS

impact Innovation with Integrity Maximum Impact Definitive Answers UHR-TOF MS Maximum Impact Definitive Answers impact Innovation with Integrity UHR-TF MS Redefining Accurate Mass LC-MS/MS Until now, mass spectrometry technologies have forced scientists to choose between performance

More information

New Approaches to Quantitative Proteomics Analysis

New Approaches to Quantitative Proteomics Analysis New Approaches to Quantitative Proteomics Analysis Chris Hodgkins, Market Development Manager, SCIEX ANZ 2 nd November, 2017 Who is SCIEX? Founded by Dr. Barry French & others: University of Toronto Introduced

More information

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental Samples Michael S.Young, Jeremy C. Shia, Kim vantran, Kevin M. Jenkins and Masayo Yabo Waters Corporation 34 Maple Street,

More information

Instrumental Solutions for Metabolomics

Instrumental Solutions for Metabolomics Instrumental Solutions for Metabolomics Dr. Desislav Donchev US14702384-16012196010132-S01-A01.tif 300 400 500 600 700 800 3100 3200 3300 3400 3500 3600 3700 3800 Color Scale R = [52 1484] G = [26 514]

More information

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study Application note Biotherapeutics and Biologics Authors Suresh Babu C.V., Anne

More information

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution Rapidly Identify Top Metabolites with the SCIEX X500R QTOF System and MetabolitePilot TM 2.0 Software Shaokun Pang and Ian Moore SCIEX,

More information

Separation of Native Monoclonal Antibodies and Identification of Charge Variants:

Separation of Native Monoclonal Antibodies and Identification of Charge Variants: Separation of Native Monoclonal Antibodies and Identification of Charge Variants: Teamwork of the Agilent 31 OFFGEL Fractionator, Agilent 21 Bioanalyzer and Agilent LC/MS Systems Application Note Biosimilar

More information

Increasing Throughput and Efficiency with Exactive LC/MS and Triple Quadrupole LC/MS/MS

Increasing Throughput and Efficiency with Exactive LC/MS and Triple Quadrupole LC/MS/MS Increasing Throughput and Efficiency with Exactive LC/MS and Triple Quadrupole LC/MS/MS Nicholas Duczak Thermo Scientific Annual Mass Spectrometry Users Meeting Somerset, NJ October 12th, 2011 Lead Finding

More information

ENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note

ENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note ENVIRONMENTAL ANALYSIS A TURN-KEY GUARANTEED ANALYSER FOR THE ROUTINE MEASUREMENT OF GLYPHOSATE AND AMPA IN DRINKING WATER (EUROPEAN DRINKING WATER DIRECTIVE 98/83/EC) AND OTHER ENVIRONMENTAL WATER SAMPLES

More information

Waters Pesticide Screening Solutions: Nuove Frontiere nell Analisi di pesticidi Miguel Ángel Cortés, Waters Manuela Cuccurullo, Waters

Waters Pesticide Screening Solutions: Nuove Frontiere nell Analisi di pesticidi Miguel Ángel Cortés, Waters Manuela Cuccurullo, Waters Waters Pesticide Screening Solutions: Nuove Frontiere nell Analisi di pesticidi Miguel Ángel Cortés, Waters Manuela Cuccurullo, Waters MS Technology day, Milan March 12 2013 Waters Corporation 1 The purpose

More information

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles Application Note Biotherapeutics and Biosimilars Authors James Martosella, Alex

More information

Expand Your Research with Metabolomics and Proteomics. Christine Miller Omics Market Manager ASMS 2017

Expand Your Research with Metabolomics and Proteomics. Christine Miller Omics Market Manager ASMS 2017 Expand Your Research with Metabolomics and Proteomics Christine Miller Omics Market Manager ASMS 2017 New Additions to Agilent Omics Workflows Acquisition Ion Mobility Q-TOF IM All Ions MS/MS Find Features

More information

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 641 Triple Quadrupole LC/MS Application Note Environmental Author Toni Hall Wessex Water Bath, UK Abstract A method for the

More information

Targeted and Untargeted Screening of Microcystins in Lake Water Samples Using High Resolution Mass Spectrometry INTRODUCTION

Targeted and Untargeted Screening of Microcystins in Lake Water Samples Using High Resolution Mass Spectrometry INTRODUCTION Targeted and Untargeted Screening of Microcystins in Lake Water Samples Using High Resolution Mass Spectrometry Lauren Mullin, 1 Xavier Ortiz Almirall, 2 Stuart Oehrle, 1 and Adam Ladak 1 1 Waters Corporation,

More information

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY AGILENT 6490 TRIPLE QUADRUPOLE LC/MS SYSTEM WITH IFUNNEL TECHNOLOGY CLEARLY BETTER SENSITIVITY

More information

Waters QUATTRO PREMIER XE

Waters QUATTRO PREMIER XE Www.IetLtd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Waters QUATTRO PREMIER XE Looking for a more intelligent way to overcome these

More information

Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns

Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns Michael McGinley, Jeff Layne, and Vita Knudson Phenomenex, Inc., 411 Madrid Ave.,Torrance,

More information

Mass Detection for the Chromatographer Waters ACQUITY QDa Detector

Mass Detection for the Chromatographer Waters ACQUITY QDa Detector Mass Detection for the Chromatographer Waters ACQUITY QDa Detector Warren B Potts III Senior Director Americas Marketing warren_potts@waters.com 2017 Waters Corporation 1 Agenda Overview of technology

More information

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma Yun Wang Alelyunas, Mark D. Wrona, Jim Murphy, Angela Doneanu, Gregory

More information

Eoin F.J. Cosgrave, Matthew A. Lauber, Robert Birdsall, and Sean M. McCarthy Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION

Eoin F.J. Cosgrave, Matthew A. Lauber, Robert Birdsall, and Sean M. McCarthy Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION New Capabilities for Monitoring Released N-Glycans through the Combined Use of RapiFluor-MS Labeling, ACQUITY UPLC H-Class Bio System, and Serial Fluorescence/ACQUITY QDa Mass Detection Eoin F.J. Cosgrave,

More information

Chemometrics. Chemometrics Applied to a Metabonomic Study of Mouse Urine. Application Note. Abstract

Chemometrics. Chemometrics Applied to a Metabonomic Study of Mouse Urine. Application Note. Abstract 38-1214 Chemometrics Application Note Chemometrics Applied to a Metabonomic Study of Mouse Urine Abstract The objective of metabonomics is to evaluate physiological response of an organism whose metabolism

More information

With the globalization of trade, food production

With the globalization of trade, food production November 2008 Comprehensive Screening, Confirmation, and Quantification of Organic Pesticides in Foods by GC MS and LC MS The global focus on keeping food safe has intensified, resulting in major changes

More information

Application Note: Overview. Introduction

Application Note: Overview. Introduction Application Note: 10014 Use of a Novel Large Volume Splitless Injection Technique and Sequential Full Scan/SIM for Simultaneous Screening and Confirmation of Toxicological Specimens Thermo Fisher Scientific

More information

Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass

Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass Application Note: 529 Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass Xiang He, Marta Kozak; Thermo Fisher Scientific, San Jose,

More information

AB SCIEX TripleTOF 5600 SYSTEM. High-resolution quant and qual

AB SCIEX TripleTOF 5600 SYSTEM. High-resolution quant and qual AB SCIEX TripleTOF 5600 SYSTEM High-resolution quant and qual AB SCIEX TripleTOF 5600 SYSTEM AB SCIEX is a global leader in the development of life science analytical technologies that help answer complex

More information

New Diagnostic Method for Pancreatic Cancer by Profiling of Metabolites in Serum Using GC/MS

New Diagnostic Method for Pancreatic Cancer by Profiling of Metabolites in Serum Using GC/MS C146-E 6-E156 New Diagnostic Method for Pancreatic Cancer by Profiling of Metabolites in Serum Using GC/MS Dr. Masaru Yoshida, Division of Metabolomics Research, Division of Gastroenterology, The Integrated

More information

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS Quantitative Method for the Determination of Potentially Mutagenic Impurities of Ondansetron Using UPC 2 Coupled with a Xevo TQ-S micro Jennifer Simeone, Paula Hong, and Patricia R. McConville Waters Corporation,

More information

performance and throughput

performance and throughput Agilent 6100 Series Single Quadrupole LC/MS Systems CLEARLY BETTER performance and throughput with day-after-day reliability Step up to clearly better sensitivity, selectivity, and high-quality spectral

More information

Customer Insights. Innovation with Integrity. Feeding Forensics: Novel Instruments for Advanced Drug Screening Analysis.

Customer Insights. Innovation with Integrity. Feeding Forensics: Novel Instruments for Advanced Drug Screening Analysis. Customer Insights Feeding Forensics: Novel Instruments for Advanced Drug Screening Analysis Innovation with Integrity Mass Spectrometry Feeding Forensics: Novel Instruments for Advanced Drug Screening

More information

Agilent Metabolomics Laboratory: The breadth of tools you need for successful metabolomics research

Agilent Metabolomics Laboratory: The breadth of tools you need for successful metabolomics research AT A GLANCE Metabolomics is a logical complement to large-scale expression profiling and proteomics studies, offering valuable insight into the biochemistry of organisms. But metabolomics also presents

More information

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1 Routine Characterization of mabs and Other Proteins Patrick Boyce Biopharmaceutical Marketing Manager Europe and India 2011 Waters Corporation 1 Agenda Why? What scientific challenges? Technology Example

More information

Clearly Better LC/MS Solutions

Clearly Better LC/MS Solutions Clearly Better LC/MS Solutions A compendium of product information, technical articles, and applications How Agilent s LC and MS systems are clearly better together for high-throughput quantitation, high-resolution

More information

Analysis of Triazine Herbicides in Drinking Water Using LC-MS/MS and TraceFinder Software

Analysis of Triazine Herbicides in Drinking Water Using LC-MS/MS and TraceFinder Software Application Note: 478 Analysis of Triazine Herbicides in Drinking Water Using LC-MS/MS and TraceFinder Software Jonathan R. Beck, Jamie K. Humphries, Louis Maljers, Kristi Akervik, Charles Yang, Dipankar

More information

Urinary Drug Confirmation of Selected Analytes

Urinary Drug Confirmation of Selected Analytes Liquid Chromatography Mass Spectrometry SSI-LCMS- Urinary Drug Confirmation of Selected Analytes LCMS-8 Summary: Forty analytes, and the associated internal standards for each, are included in this urinary

More information

Chapter 2 deals with LC-ESI-MS/MS studies on forced degradation of abacavir sulphate an anti HIV drug.

Chapter 2 deals with LC-ESI-MS/MS studies on forced degradation of abacavir sulphate an anti HIV drug. The drug discovery and development process has undergone dramatic changes particularly in the last decade. Progress in drug discovery has been fuelled by improvements in methodologies and technologies

More information

High-Throughput LC/MS Purification of Pharmaceutical Impurities

High-Throughput LC/MS Purification of Pharmaceutical Impurities High-Throughput LC/MS Purification of Pharmaceutical Impurities Application Note Small Molecule Pharmaceuticals Author Florian Rieck Agilent Technologies, Inc. Waldbronn, Germany Abstract Legal regulations

More information

Simultaneous Quantitation of a Monoclonal Antibody and Two Proteins in Human Plasma by High Resolution and Accurate Mass Measurements

Simultaneous Quantitation of a Monoclonal Antibody and Two Proteins in Human Plasma by High Resolution and Accurate Mass Measurements Simultaneous Quantitation of a Monoclonal Antibody and Two Proteins in Human Plasma by High Resolution and Accurate Mass Measurements Paul-Gerhard Lassahn 1, Kai Scheffler 2, Myriam Demant 3, Nathanael

More information

Purification Workflow Management

Purification Workflow Management Ronan Cleary and Paul Lefebvre Waters Corporation, Milford, MA, USA INTRODUCTION A standard requirement for drug discovery screening of synthetic libraries is that the test compounds must have a minimum

More information

Analysis of Triazine Herbicides in Drinking Water Using LC-MS/MS and TraceFinder Software

Analysis of Triazine Herbicides in Drinking Water Using LC-MS/MS and TraceFinder Software Application Note: 478 Analysis of Triazine Herbicides in Drinking Water Using LC-MS/MS and TraceFinder Software Jonathan R. Beck, Jamie K. Humphries, Louis Maljers, Kristi Akervik, Charles Yang, Dipankar

More information

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC Analysis of Intact and Fragmented mabs and ADC Application Note Biotherapeutics and Biologics Author Suresh Babu C.V. Agilent

More information

Agilent Solutions for Metabolomics EMERGING INSIGHTS

Agilent Solutions for Metabolomics EMERGING INSIGHTS Agilent Solutions for Metabolomics EMERGING INSIGHTS Understanding Metabolic Fingerprints A Powerful Way to Investigate Biology What is Metabolomics? Metabolomics is the study of the metabolite content

More information

AB SCIEX 4500 SERIES MASS SPECTROMETERS. The new workhorse for LC/MS/MS AB SCIEX 4500 SERIES MASS SPECTROMETERS

AB SCIEX 4500 SERIES MASS SPECTROMETERS. The new workhorse for LC/MS/MS AB SCIEX 4500 SERIES MASS SPECTROMETERS AB SCIEX 4500 SERIES MASS SPECTROMETERS The new workhorse for LC/MS/MS AB SCIEX 4500 SERIES MASS SPECTROMETERS The new AB SCIEX 4500 Series takes the legendary API 4000 platform and intelligently re-engineers

More information

Application Note. Authors. Abstract. Ravindra Gudihal Agilent Technologies India Pvt. Ltd. Bangalore, India

Application Note. Authors. Abstract. Ravindra Gudihal Agilent Technologies India Pvt. Ltd. Bangalore, India Quantitation of Oxidation Sites on a Monoclonal Antibody Using an Agilent 1260 Infinity HPLC-Chip/MS System Coupled to an Accurate-Mass 6520 Q-TOF LC/MS Application Note Authors Ravindra Gudihal Agilent

More information

Simplifying Methods Transfer: Novel Tools for Replicating Your Established Methods on an ACQUITY Arc System

Simplifying Methods Transfer: Novel Tools for Replicating Your Established Methods on an ACQUITY Arc System Simplifying Methods Transfer: Novel Tools for Replicating Your Established Methods on an ACQUITY Arc System Paula Hong, Richard Andrews, Peyton C. Beals, and Patricia R. McConville Waters Corporation,

More information

Application Note. Abstract. Authors. Environmental

Application Note. Abstract. Authors. Environmental Identification of a Panel of 20 Indicator Compounds in Wastewater Effluent Using Rapid, Direct Injection LC/MS/MS on the Agilent 6490 Triple Quadrupole LC/MS Application Note Environmental Authors Shimin

More information

SPECTROSCOPIC METHODS FOR VOCs DETERMINATION

SPECTROSCOPIC METHODS FOR VOCs DETERMINATION SPECTROSCOPIC METHODS FOR VOCs DETERMINATION Monica Culea 1, O.Cozar 1, Cora Craciun 1, R.Fechete 2, Andreea Iordache 1, E.Culea 2 1 Faculty of Physics, Babes-Bolyai University of Cluj-Napoca, 400084 Cluj-

More information

NOTICE OF INTENDED DECISION TO ENTER INTO A SINGLE SOURCE CONTRACT (PUR 7778)

NOTICE OF INTENDED DECISION TO ENTER INTO A SINGLE SOURCE CONTRACT (PUR 7778) NOTICE OF INTENDED DECISION TO ENTER INTO A SINGLE SOURCE CONTRACT (PUR 7778) This Notice of Intended Decision to Enter into a Single Source Contract is posted in accordance with section 287.057(3), Florida

More information

For Routine Applications

For Routine Applications Thermo Scientific Q Exactive Focus Orbitrap LC-MS/MS System HRAM Selectivity with Confidence For Routine Applications Proven Durable Affordable Transforming Routine Quantitation Designed for routine applications,

More information

Ultrapure water: LC-MS suitability tests

Ultrapure water: LC-MS suitability tests Ultrapure water: LC-MS suitability tests Application details Contaminations such as ions and organic traces present in ultrapure water affect LC- MS analyses and decrease perfomance of the analytical instumentation.

More information

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

Quantification of genotoxic Impurity D in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 12 Series RRLC and 641B Triple Quadrupole LC/MS Application Note Manufacturing Process Development Author Siji Joseph Agilent

More information

The Agilent 6545 Q-TOF LC/MS System. The Answers You Need:

The Agilent 6545 Q-TOF LC/MS System. The Answers You Need: The Agilent 6545 Q-TOF LC/MS System The Answers You Need: Better, Faster, Easier The Agilent 6545 Q-TOF LC/MS System Faster Answers Better Measurements Easier High Performance Results The new 6545 Q-TOF

More information

The Agilent 6545 Q-TOF LC/MS System. The Answers You Need:

The Agilent 6545 Q-TOF LC/MS System. The Answers You Need: The Agilent 6545 Q-TOF LC/MS System The Answers You Need: Better, Faster, Easier The Agilent 6545 Q-TOF LC/MS System Faster Answers Better Measurements Easier High Performance Results The new 6545 Q-TOF

More information