1 THE HOBAS A PUBLICATION HIGHLIGHTING THE TECHNICAL AND PRACTICAL USES OF HOBAS PIPE Hobas Pipe USA, Inc. November 1998 MICROTUNNELED FORCE MAIN NEAR FLAWLESS PERFORMANCE The first ever Hobas pressure pipe installed by microtunneling (re mote-controlled jacking) is nearly complete with almost flawless performance in Orlando on the Bennett Rd. project. The new 36" diameter sewer force main includes over 4700 feet of 100 psi rated, 260 ton, centrifugal cast, fiberglass-reinforced polymer mortar (CCFRPM) pressure jacking pipes supplied in 20 foot sections, field assembled with flush FWC coupling joints. I N S I D E THE HOBAS Product Profile Sliplining Installations 2 Las Vegas Grows with Hobas Again 4 Trouble Free Rehabilitation 5 Hobas Microtunnel Saves Millions of $ 6 Conference Exhibits 8 Peak jacking loads did not exceed 120 tons. MICROTUNNELING CHEAPER The line also included 14,000 feet of PVC pipe, which was installed by open cut construction. However, due to interference from numerous other utilities, some adjacent wetlands, surface drainage ditches, crossing of route 436, heavy area traffic and a building in the 1000 ft. drive completed at 60 ton jacking load. right-of-way, a portion of the job was specified for microtunnel installation only. Not only did the trenchless construction method solve or avoid most of these conflicts, it was also substantially lower in cost versus open cut for this segment! (continued on page 7)

2 PRODUCT PROFILE SLIPLINING INSTALLATIONS - HOBAS PIPES ARE THE PREMIER PERFORMER INTRODUCTION Although the majority of Hobas pipes are installed by common open cut construction, these smooth wall, high strength pipes have earned their superior reputation and notoriety primarily due to their success in trenchless applications. The most popular of the trenchless installations is sliplining rehabilitation, where Hobas pipes are clearly the premier product. CHARACTERISTICS Description Generically, Hobas pipes are centrifugal-cast, fiberglass-reinforced, polymer mortar (CCFRPM). Scope * Diameters: 12" to 102" currently available. * Standard classes: - Stiffness: Most commonly 36 or 46 psi, although other values, higher or lower are available and are sometimes needed. - Pressure: Most applications are non-pressure, however, ratings for 50, 100, 150, 200 and 250 psi are available. * Section lengths: 20 ft. is standard, but 10, 6.5, 5, 4 and 2.5 ft. sections are used in curves or when small pits are necessary. * Joints: Several gasket-sealed, bell-spigot configurations are suitable based on fit and service pressure: - Non-pressure: Low-profile or flush (see figure). - Pressure: FWC coupling with overwrap (see figures). * Fittings: Although not used frequently in this construction method, a wide variety of mitered and molded fittings are available: Elbows Manholes Tees Wyes Reducers Laterals Nozzles Flanges Hobas pipes smooth interior surface has superior hydraulic characteristics. Reconnection of most lateral services is accomplished using Inserta- Tee fittings (up to 12"). APPLICATIONS Majority of applications are sanitary sewer interceptors, however, the pipes are also ideal for relining other services including storm drainage, industrial effluents, culverts and sometimes force mains. INSTALLATION Preparation of the existing (host) pipe For non-pressure services, the host pipe may be maintained in operation during the lining process. Obstructions such as roots, large joint offsets, rocks or other debris, etc. that would prevent passage or damage the liner pipe sections must be removed or repaired prior to installing the new pipe. Before starting the liner insertion, verify the existing pipe diameter is sufficient by pulling a mandrel through the line. Liner pipe insertion Access to the host pipe is normally achieved via a shaft constructed directly above the line. Liner pipes may be pushed or pulled (from the back end) into the existing line. The pipes must be inserted spigot end first with the bell end trailing. Frequently the leading pipe spigot end is protected by a nose piece designed to rideup and over offset joints and other minor inconsistencies or small debris in the invert. Distances lnsertion pushing distances may be limited by turns (PI s) in the host pipe. However, when the existing pipe alignment allows, push distances of 2000 ft. to 3000 ft. are routine and up to 5600 ft. have already been accomplished. Grouting Generally the annular space between the liner OD and host ID is filled with grout to provide support to the liner to resist external loads, to prevent water and soil from entering the annulus and to fix the liner pipe position. Maximum grouting pressure is a function of the liner stiffness, annulus size and flow conditions. Experience Over 500,000 ft. installed by sliplining by mid BENEFITS Hobas CCFRPM pipes provide many benefits to the user and installer. Some are applicable to any installation method and may be termed universal. Others are most significant and valuable specifically on trenchless installations such as sliplining. 2

3 PRODUCT PROFILE Universal Benefits Features Benefits Sliplining Benefits Features Benefits Inherent corrosion resistance Leak-free joints Push-together assembly Lightweight Resilient inner liner Mold smooth, consistent O.D. Smooth l.d. Long service life even in corrosive environments No add-on linings or coatings to install, inspect or maintain Hydraulics unchanged over time Zero infiltration lowers treatment costs No undermining of structures above No ground water pollution Pass tests easily; the first time Fast joining No welding required Less expensive handling equipment Excellent abrasion resistance High crack resistance Pipes may be cut anywhere and assembled with gasketed joints with only end chamfering preparation needed Superior hydraulic characteristics High flow capacity Significant energy savings in pumped systems Segmented pipes with gasketsealed joints Constant, smooth OD Solid wall with ideal density High compressive strength Lightweight High stiffness & flex strength Low profile wall Flush and low profile bell-spigot joints 26 diameters between 18" & 102" Superior hydraulic characteristics Small shafts Live insertion No by-pass pumping required Minimize surface disruption Lower push loads Longest push distances Fewer shafts required Highest reliability and safety margin Lowest installation cost Highest allowable grouting pressure High load & deep covers capability Pipes are rugged & durable Largest ID to fit most all lines Improve flow capacity after lining Joints with angular rotation capability Liner negotiates host alignment easily Some curves & Pl s may be lined CONCLUSION Specify and use Hobas centrifugal cast fiberglass-reinforced polymer mortar pipes on your next jacking project to experience and enjoy these many, unique, cost saving benefits. Low profile bell-spigot Flush bell-spigot. 3

4 LAS VEGAS GROWS WITH HOBAS AGAIN Hobas pipes safely withstand deep burials. Although over 1000 miles apart, Hobas Pipe USA, Inc. and Las Vegas have an important common trait; both are growing rapidly. Hobas sales in the U.S. have tripled in the last 5 years and Las Vegas has experienced explosive growth also. To maintain service, the utility infrastructure in the Las Vegas area has been continually expanded during the 80 s and 90 s. Hobas pipes have played a significant role having been utilized on several jobs. The recently completed West Russell Road Relief Sewer Phase 1 of the Clark County Sanitation District is one such project. This new interceptor, installed by open cut construction, included 2.5 miles of 36" and 42" Hobas centrifugally cast fiberglass-reinforced polymer mortar (CCFRPM) pipes. CHALLENGING CONDITIONS Due to low initial flows, project designer G. C. Wallace, Inc. of Las Vegas, needed pipes with corrosion resistance to septic conditions. Structural integrity was also critical because 90% of the pipes have over 20 feet of cover with a maximum of 27 feet. Additionally, most of the alignment is under roads which were unpaved during the construction. Finally, to protect the surroundings and minimize flows, no visible leaks were allowed and the lines had to pass an air test. These criteria led to the specification of SN 46 Hobas CCFRPM, RCP with 300 deg. PVC lining or RSC 160 HDPE pipes. TROUBLE-FREE & FAST Hobas pipes were selected by installer, Dow Industries of Las Vegas, primarily because of a lower installed cost. Even though this project was Dow s first using Hobas pipes, the job was virtually trouble-free and all of the pipes were installed in less than 4 months. Despite the deep cuts, typical daily production was over 200 feet. Dow particularly liked the tight, yet easy to assemble, push-together, gasket-sealed FWC coupling joints. Additionally, Dow was pleased by the ease and speed of field length adjustments. Since the FWC coupling seals directly on the molded pipe exterior surface, the pipes may be cut anywhere on the barrel and connected using the couplings with only an end chamfer required. HIGH PERFORMANCE The CCFRPM pipes were bedded in a dumped surround of 0.75" minus crushed rock. This burial and the pipes 46 psi stiffness combined to achieve a high quality installation. Not only did the entire line pass the 5% deflection requirement with no remedial work, all measurements taken revealed no deflections exceeding 1.5%. Better yet, 3.5 psi line air tests all also passed with no leakage at all! This performance is not unusual for Hobas installations and actually is a repeat of a previous Las Vegas project. With this 5th city of lights project successfully complete, Hobas is now preparing to deliver to Las Vegas over 3 miles of 54 and 66 pipes for another open cut interceptor, the Sandhill Relief Sewer. Field length adjustments are fast and easy due to the constant pipe OD and the FWC coupling. Handling is easy and inexpensive with rugged, yet lightweight Hobas pipes. 4

5 TROUBLE FREE REHABILITATION High performance, consistent Hobas centrifugal cast, fiberglass-reinforced polymer mortar (CCFRPM) pipes contributed to another trouble-free sliplining installation on the recently completed North Long Beach Trunk Sewer Section 1 Rehabilitation. This project, another in a long series for the County Sanitation Districts of Los Angeles County (LACSD), consisted of over 2 miles of existing deteriorated 30 RCP interceptor lined with 26" Hobas pipes. MANY SPECIFIC NEEDS Similar to many past LACSD rehab projects, this liner also had to be installed without by-pass pumping of the sewage flow. Additionally, a 46 psi minimum pipe stiffness was required to resist the maximum annular space grouting pressure of 12 psi. This pipe class had to be achieved with a maximum OD of 28" to enable a low-risk insertion fit and with a minimum ID of 26" to assure adequate flow recovery. As always, the new liner had to be resistant to future sulfide attack and the periodic caustic treatment program. Finally flush gasket-sealed bell-spigot joints were needed for quick assembly, leak-free performance and a smooth exterior surface. This combination of critical criteria again led LACSD engineers to specify only CCFRPM pipes. The Buntich crew celebrates inserting 2,000 ft. of liner (100 pipes) in just 6.5 hours. EASY INSERTION Due to 3 siphons and 2 significant Pl s in this otherwise straight section, contractor Mladen Buntich of Sunland, utilized 5 access pits to insert the mostly 20 foot long liner pipes. Push loads were low with a maximum of only 20 tons needed even on the longest drive of 2450 feet. Insertion was fast because of the push-together joints and Buntich s new pushing machine. The versatile, hydraulic powered, chain drive unit installed 100 pipes (2000 feet) in only 6.5 hours, a rate of less than 4 minutes per section! Despite this success, the most pleasing achievement may have been no damaged pipes! placed in 1 lift, completed the lining portion of the project. Final video revealed a tight, sound system installed trouble-free! Now with over two dozen projects completed utilizing over 120,000 feet of Hobas CCFRPM liner pipes, LACSD is continuing their interceptor rehabilitation program frequently using more of the same. Currently no less than 5 additional projects totaling over 20,000 feet of Hobas CCFRPM liner pipes are in various stages of production and construction. REPEAT SUCCESS Prior to grouting, the annular space was standpipe tested to the maximum grout pressure with no leaks detected in the liner pipes or joints. Annulus grouting, with an 80 pcf cellular foam mix Hobas flush gasket-sealed joints assemble quickly and insert easily. Inspectors witness fast lining process. Connection in the access pit of pipes pushed opposite directions is made using Hobas closure coupling. 5

6 HOBAS MICROTUNNEL SAVES MILLIONS OF DOLLARS Use of microtunneling and Hobas centrifugal cast, fiberglass-reinforced polymer mortar pipes on the Southeast Interceptor II project in Derby, Kansas reduced costs over 50% compared to conventional methods. Additionally, the trenchless installation pacified residents anger over the destruction of the environment and disruption of their community that occurred on phase 1 of this line built several years ago by open cut DEMANDING PERFORMANCE The new 36" line extends this sanitary sewer another 3000 feet and will service projected growth in the area for the next 40 years. Therefore, since flows will be low for several years, a corrosion resistant pipe was needed to withstand the septic conditions that are certain to occur. Further, with cover depths up to 44 feet beneath streets, a strong, structurally reliable pipe was a must. Finally, to control leakage, a 50 inch-gallon (gallons / inch of diameter / mile of line / day) infiltration test was included. To meet these requirements, project designers, Professional Engineering Consultants of Wichita, specified only CCFRPM or extra strength VCP pipes and gasket-sealed bell-spigot joints. Hobas pipes suitable for depths over 40 ft. MOST RELIABLE installation contractor, BRH Garver of Houston chose Hobas pipes because their dimensional consistency and wall resiliency have proven to result in the lowest jacking loads and the highest reliability. Garver s confidence was rewarded during the installation. The job was completed in 6 separate drives with the longest being 625 feet. The operating push loads through the clay and shale soils rarely exceeded 30 tons with a maximum peak load of 45 tons! Daily production averaged 106 feet working 10 hours with a single best day of 16 joints (160 feet). Best of all, no pipes were damaged or broken during installation or handling! (continued on page 7) Neat compact job site pleased the community residents. 6

7 MICROTUNNELED SAVES MILLIONS $ (continued from page 6) SATISFIED CUSTOMER Not only was this Derby s first microtunnel experience, it was the first significant microtunnel installation in Kansas. The job was successful in every way as it pleased residents by saving trees, preserving wildlife and minimizing disruption, as well as saving taxpayers $2.4 million in construction costs. Additionally, because the line tested leak-free under 20 to 30 feet of head, structural undermining is prevented and flow capacity is preserved by eliminating infiltration. And perhaps most important, the corrosion resistant Hobas CCFRPM pipes will still be like new well beyond the project design life. Smooth, constant OD Hobas pipes have the lowest jacking loads. MICROTUNNELED FORCE MAIN (continued from page 1) HOBAS ONLY SPEC Since Orlando Standards require all force mains to be rated for 100 psi, the prime design consideration for project consultant, Sverdrup Civil of Orlando, was a reliable pressure pipe suitable for a jacking installation. Additionally, depending on the Bennett Rd. Pump Station volume, the new pipe operates, alternately, as both a force main and a gravity flow line. This demanded an on grade installation (another reason for microtunneling) and a corrosion resistant pipe due to likely generation of sulfides. Further, because the force main was built for flow relief and to handle some redirected flows, good hydraulic characteristics were also important. Because of these requirements only Hobas CCFRPM pipes or equal were allowed by the specifications. INSTALLATION PERFECTION After further consideration of possible alternative materials, Hobas pipes were purchased by contractors, Peters (general) of Owensboro, Kentucky and Kerr (microtunnel sub) of Palmetto, Florida. The microtunneling was accomplished in eight drives ranging from 270 feet to 1000 feet long. Despite the predominately sandy soil, jacking loads were consistently low. Peak start-up loads did not exceed 120 tons and operating loads, even at the conclusion of the All pipes and joints were leak-free at 100 psi after jacking installation. longest drive, were less than 60 tons! This performance allowed all drives to be completed without the use of any intermediate jacking stations. The jacking operation was so smooth, that daily production of 140 feet was frequently achieved with a maximum of 180 feet completed in 9 hours. Perhaps most significant was no pipes were damaged or broken during installation or handling. LEAK-FREE PERFORMANCE The specs required leak-free performance during a 100 psi pressure test for 2 hours on the installed piping. Kerr tested each finished drive section separately shortly after jacking was complete. Except for one of the stainless steel 2" grout bushings (which were factory installed in half of the pipes), each segment passed the pressure test on the first attempt! The cracked lamination of the single leaking bushing was permanently restored in place by a Hobas field representative prior to the successful retest of that segment. Subsequently, the jacked pipes twice more passed the pressure test when Peters made tie-ins to the PVC portions. The nearly flawless performance pleased the City, the designer and the installers. With this success behind us, a second installation of Hobas pressure jacking pipe, 42" diameter, will begin during the 4th quarter on a project in New Jersey. 7

8 Hobas Pipe USA, Inc Richey Road Houston, Texas (281) BULK RATE U.S POSTAGE PAID PERMIT #1339 HOUSTON TX VISIT OUR BOOTH AT THE FOLLOWING UPCOMING TRADE SHOW EXHIBITS: DECEMBER 9-11,1998 Power Generation International Orange County Convention Center Orlando, FL Booth: #1269 JANUARY 12-14,1999 Underground Construction Technology George R. Brown Convention Center Houston, TX Booth: #814 FEBRUARY 11-13, 1999 NUCA 99 Long Beach Convention Center Long Beach, CA Booth: #211 MARCH 1-3, 1999 TAPPI 99 Georgia World Congress Center Atlanta, GA APRIL 6-9, SAME George R. Brown Convention Center Houston, EX APRIL 26-29, 1999 NACExpo 99 Henry B. Gonzalez Convention Center San Antonio, TX Remember, you can visit us anytime at:

ITEM NO SLIPLINING SANITARY SEWERS

ITEM NO SLIPLINING SANITARY SEWERS ITEM NO. 1100 SLIPLINING SANITARY SEWERS 1100.1 DESCRIPTION: Sliplining is accomplished by pulling or pushing liner pipe into existing sewers by use of mechanical or hydraulic equipment. Once in place,

More information

Overview. Advanced Dual Wall Profile Construction. Superior Polypropylene Material

Overview. Advanced Dual Wall Profile Construction. Superior Polypropylene Material HP Storm Pipe 12 60 HP STORM pipe 12 60 FOR Storm applications Overview An addition to our proven line of pipe products, HP (High Performance) Storm is a high-performance polypropylene (PP) pipe for gravity-flow

More information

Tough pipe for a tough environment

Tough pipe for a tough environment Sanitary Sewer Pipe Tough pipe for a tough environment SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling, toughness

More information

Weholite LIGHTWEIGHT PIPE SYSTEM

Weholite LIGHTWEIGHT PIPE SYSTEM Weholite LIGHTWEIGHT PIPE SYSTEM The lightweight pipe that takes a heavier load Weholite pipe is large diameter, profile wall pipe made from highdensity polyethylene (HDPE) resin, which is manufactured

More information

PipeLine. Increasing Sewer Capacity. January 2015, Issue 72

PipeLine. Increasing Sewer Capacity. January 2015, Issue 72 January 2015, Issue 72 PipeLine Contents 1 I Increasing Sewer Capacity 4 I HOBAS Pipe Chosen for Large Diameter Force Main 6 I 26 Year Old Force Main Still Performing Well 8 I HOBAS Pipe Expands Field

More information

SLIPLINING Sewer Rehabilitation

SLIPLINING Sewer Rehabilitation SLIPLINING Sewer Rehabilitation Centrifugally Cast Fiberglass Reinforced Polymer Mortar Pipe Bijan Khamaian 1/12/17 Seattle Agenda OIntroduction on Hobas OSlipline Pipe Product details OFeatures and benefits

More information

THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS TM. HP Storm Pipe 12 60

THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS TM. HP Storm Pipe 12 60 THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS TM HP Storm Pipe 12 60 PiPe 12 60 FOR STORM applications Overview An addition to our proven line of pipe products, HP Storm is a high-performance polypropylene

More information

SaniTite. HP Sewer Pipe 300 mm 750 mm

SaniTite. HP Sewer Pipe 300 mm 750 mm SaniTite HP Sewer Pipe 300 mm 750 mm sanitite HP SEWER Pipe 300 mm 750 mm Certified to CSA B182.13 A new addition to our proven line of pipe products, SaniTite HP (High Performance) couples advanced Polypropylene

More information

CHAPTER 6 - SANITARY SEWER

CHAPTER 6 - SANITARY SEWER CHAPTER 6 - SANITARY SEWER 6.1 GENERAL This section covers the requirements for PVC plastic sewer pipe materials and installation in sanitary sewer construction. 6.2 PIPE PVC gravity sewer pipe and fittings

More information

1 Revised: 2019 Edition

1 Revised: 2019 Edition STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm Sewers B. Abandonment of Storm Sewers 1.02 DESCRIPTION OF WORK A. Construct storm sewers. B. Abandon storm sewers. 1.03 SUBMITTALS Comply with

More information

January 2019, Issue 77. PipeLine

January 2019, Issue 77. PipeLine January 2019, Issue 77 PipeLine CONTENTS 1 I Last-Minute Design Change Benefits Akron Project 3 I Product Profile: The HOBAS FWC 4 I First Section of Anacostia River Tunnel Opens 8 I Attention Readers

More information

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING)

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING) PART 1 - GENERAL TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING) 1.01 SECTION INCLUDES A. Trenchless Installation of Carrier Pipe with Casing Pipe B. Trenchless Installation of Carrier Pipe without

More information

SaniTite. HP Sewer Pipe 300mm 750mm

SaniTite. HP Sewer Pipe 300mm 750mm SaniTite HP Sewer Pipe 300mm 750mm SANITITE HP SEWER PIPE 300mm 750mm Certified to CSA B182.13 A new addition to our proven line of pipe products, SaniTite HP (High Performance) couples advanced Polypropylene

More information

DuroMaxx. Steel Reinforced Polyethylene Pipe. Dur A STEEL REINFORCED POLYETHYLENE PIPE. Sanitary Irrigation Storm Sewer Detention

DuroMaxx. Steel Reinforced Polyethylene Pipe. Dur A STEEL REINFORCED POLYETHYLENE PIPE. Sanitary Irrigation Storm Sewer Detention Steel Reinforced Polyethylene Pipe Dur A STEEL REINFORCED POLYETHYLENE PIPE Sanitary Irrigation Storm Sewer Detention Key Performance Advantages The Strength of Steel. The Durability of Plastic. It s the

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 848 SANITARY SEWERS

San Antonio Water System Standard Specifications for Construction ITEM NO. 848 SANITARY SEWERS ITEM NO. 848 SANITARY SEWERS 848.1 DESCRIPTION: This item shall govern the furnishing, installation and jointing of sanitary sewer pipe of the size and type specified by the project's plans and specifications.

More information

VYLON. SLIPLINER PIPE Installation Guide

VYLON. SLIPLINER PIPE Installation Guide VYLON SLIPLINER PIPE Installation Guide Table of Contents 1. Inspection When Received...1 2. Unloading...2 3. Cold Weather Handling...2 4. Storage...2 5. Recommendations...3 7. Sliplining...6 8. Bulkheads...7

More information

Concrete Pipe Joints Your Best Choice

Concrete Pipe Joints Your Best Choice Frequently Asked Questions Q. Are joints covered by National Standards? A. Yes. There are ASTM and AASHTO standards for concrete products joints. The various standards are discussed in this publication.

More information

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm Sewers B. Abandonment of Storm Sewers 1.02 DESCRIPTION OF WORK A. Construct storm sewers. B. Abandon storm sewers. 1.03 SUBMITTALS Comply with

More information

PipeLine. Large Diameter Rehabilitation in Houston. June 2016, Issue 74

PipeLine. Large Diameter Rehabilitation in Houston. June 2016, Issue 74 June 2016, Issue 74 PipeLine Contents 1 I Large Diameter Rehabilitation in Houston 4 I Naches-Selah Irrigation District Upgrades System 6 I HOBAS Pipe Used to Rehabilitate Niagara Falls Sewer 8 I Another

More information

Specifications. Chapter 13. Specifications (800) CULVERT 96

Specifications. Chapter 13. Specifications   (800) CULVERT 96 Chapter 13 WWW.CULVERT-REHAB.COM (800) CULVERT 96 Material Requirement These specifications cover the purchase of high density polyethylene (HDPE) pipe liners for lining existing culvert pipes. Pipe liners

More information

SRPE AASHTO Specifications.

SRPE AASHTO Specifications. SRPE AASHTO Specifications July 19, 2013 Steel Ribbed HDPE = SRHDPE = SRPE Now has AASHTO Design and Construction Specifications for SRPE. 2 But wait there is more AASHTO Bridge Design Specs - Section

More information

ADDENDUM NO. 4. Project Name: Olmos Basin Central Watershed Sewer Relief Line (C-3), Reaches 1 to 4

ADDENDUM NO. 4. Project Name: Olmos Basin Central Watershed Sewer Relief Line (C-3), Reaches 1 to 4 ADDENDUM NO. 4 Date: 26 October 2011 San Antonio Water System Project Name: Olmos Basin Central Watershed Sewer Relief Line (C-3), Reaches 1 to 4 Project No.: 08-2512 Solicitation No.: B-11-051-CM This

More information

DuroMaxx Steel Reinforced Polyethylene Technology. Sanitary & Storm Sewer Reline Irrigation Stormwater/CSO/SSO Detention ENGINEERED SOLUTIONS

DuroMaxx Steel Reinforced Polyethylene Technology. Sanitary & Storm Sewer Reline Irrigation Stormwater/CSO/SSO Detention ENGINEERED SOLUTIONS ENGINEERED SOLUTIONS Steel Reinforced Polyethylene Technology LEED with Contech Sanitary & Storm Sewer Reline Irrigation Stormwater/CSO/SSO Detention STEEL REINFORCED PE TECHNOLOGY Key Performance Advantages»

More information

CONCRETE PIPE JOINTS, YOUR BEST CHOICE

CONCRETE PIPE JOINTS, YOUR BEST CHOICE CONCRETE PIPE JOINTS, YOUR BEST CHOICE www.concretepipe.org FREQUENTLY ASKED QUESTIONS Q. Are joints covered by National Standards? A. Yes. There are ASTM and AASHTO standards for concrete products joints.

More information

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING)

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING) PART 1 - GENERAL TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING) 1.01 SECTION INCLUDES A. Trenchless Installation of Carrier Pipe with Casing Pipe B. Trenchless Installation of Carrier Pipe without

More information

The Complete HOBAS Guide. Centrifugally Cast, Fiberglass-Reinforced, Polymer Mortar Pipe

The Complete HOBAS Guide. Centrifugally Cast, Fiberglass-Reinforced, Polymer Mortar Pipe The Complete HOBAS Guide Centrifugally Cast, Fiberglass-Reinforced, Polymer Mortar Pipe Why Pick HOBAS? The HOBAS name on the pipe says you ve chosen the leader in pipe technology: first choice for virtually

More information

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS SECTION 02530 - SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Assessing Salem s Oldest Transmission Main for Seismic Resiliency

Assessing Salem s Oldest Transmission Main for Seismic Resiliency Assessing Salem s Oldest Transmission Main for Seismic Resiliency ASSESSING AND DEVELOPING OPTIONS TO REDUCE VULNERABILITY OF AGING CRITICAL INFRASTRUCTURE Presented by Troy Bowers, PE Jeff Jones, PE PROBLEM

More information

SECTION 39 - MANHOLES TABLE OF CONTENTS

SECTION 39 - MANHOLES TABLE OF CONTENTS Section SECTION 39 - MANHOLES TABLE OF CONTENTS Page 39-1 GENERAL... 39.1 39-2 CONCRETE MANHOLES... 39.1 39-2.01 NOT USED... 39.1 39-2.02 Concrete Storm Drain Manholes... 39.1 39-3 SADDLE SEWER MANHOLES...

More information

Wastewater Capital Projects Management Standard Construction Specification

Wastewater Capital Projects Management Standard Construction Specification CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 PRECAST CONCRETE PIPE 10.1.1 General This section covers material requirements,

More information

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa).

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa). SECTION 221313 - FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

INDUSTRIAL PIPE FITTINGS, LLC

INDUSTRIAL PIPE FITTINGS, LLC Page 1 of 9 SPIROLITE MUNICIPAL AND INDUSTRIAL ODOR CONTROL PIPING Municipal wastewater treatment plants, industrial processes and composting facilities can be assured of trouble free transport of foul

More information

A-2000 PVC Pipe for Storm Sewers and Drainage

A-2000 PVC Pipe for Storm Sewers and Drainage ENGINEERED SOLUTIONS A-2000 PVC Pipe for Storm Sewers and Drainage A-2000 Drainage Pipe Drainage systems are required to meet multiple criteria. The choice of a particular material depends upon a number

More information

ENGINEERED SOLUTIONS. Wastewater Solutions

ENGINEERED SOLUTIONS. Wastewater Solutions ENGINEERED SOLUTIONS Wastewater Solutions Municipal and Industrial Wastewater Solutions For more than 100 years (since 1904), Contech Engineered Solutions LLC has been a leader in the pipe industry. From

More information

DRAINAGE SOLUTIONS SINCE 1908 NEW PRODUCT BOSS 3000 LARGE DIAMETER STEEL REINFORCED POLYETHYLENE PIPE DURABLE LIGHTWEIGHT COST-EFFECTIVE ARMTEC.

DRAINAGE SOLUTIONS SINCE 1908 NEW PRODUCT BOSS 3000 LARGE DIAMETER STEEL REINFORCED POLYETHYLENE PIPE DURABLE LIGHTWEIGHT COST-EFFECTIVE ARMTEC. DRAINAGE SOLUTIONS SINCE 1908 NEW PRODUCT BOSS 3000 LARGE DIAMETER STEEL REINFORCED POLYETHYLENE PIPE DURABLE LIGHTWEIGHT COST-EFFECTIVE ARMTEC.COM BOSS 3000 the next generation of BOSS pipe. BIGGER. STRONGER.

More information

Specifications for SWC #110: Pipe, Pipe Liner, & Liner Installation

Specifications for SWC #110: Pipe, Pipe Liner, & Liner Installation 1. Drainage Pipe Specifications Specifications for SWC #110: Pipe, Pipe Liner, & Liner Installation 1.1 Corrugated Metal, Aluminized, and Culvert Pipe (Round) Please see TDOT standard drawing D-PB-2 and

More information

A-2000 PVC Pipe for Sanitary Sewers

A-2000 PVC Pipe for Sanitary Sewers ENGINEERED SOLUTIONS A-2000 PVC Pipe for Sanitary Sewers Engineered for Performance Manufactured by Contech Engineered Solutions, A-2000 represents the leading edge in sanitary sewer pipe technology with

More information

ULTRA FLO Storm Sewer Pipe

ULTRA FLO Storm Sewer Pipe ULTRA FLO Storm Sewer Pipe Customer Proven Innovation 1 Superior System Hydraulics CONTECH ULTRA FLO has a long history of proven performance on municipal, transportation, airport, shopping center and

More information

SECTION I FLEXIBLE PIPE VS. RIGID PIPE (GENERAL)

SECTION I FLEXIBLE PIPE VS. RIGID PIPE (GENERAL) h~i:! SECTION I FLEXIBLE PIPE VS. RIGID PIPE (GENERAL) Generally, rigid pipes have the following characteristics: made in discrete lengths use gaskets in joints to form a water-tight seal often produced

More information

The Weak Links in the Wastewater Collection System: Manholes and Access Devices. Antonio V Almeida, PE CMOM 2014 Austin Texas August 19, 2014

The Weak Links in the Wastewater Collection System: Manholes and Access Devices. Antonio V Almeida, PE CMOM 2014 Austin Texas August 19, 2014 The Weak Links in the Wastewater Collection System: Manholes and Access Devices Antonio V Almeida, PE CMOM 2014 Austin Texas August 19, 2014 Agenda Manhole Design The Manhole Paradigm past, present & future

More information

1.02 RELATED WORK: Refer to the following sections for related work:

1.02 RELATED WORK: Refer to the following sections for related work: SECTION 5100 - SANITARY SEWER MAIN PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of sanitary sewer mains and services. Topics include permits and fees, record drawings, pipe materials,

More information

SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings

SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings 1993 Specifications CSJ 0144-01-060 SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings 1. General. (1) Scope. This Section includes the furnishing, installation, and subsequent

More information

SECTION FACILITY SANITARY SEWERS

SECTION FACILITY SANITARY SEWERS SECTION 22 13 13 FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections. SANITARY SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Sanitary Sewer Gravity Mains B. Sanitary Sewer Force Mains C. Sanitary Sewer Services 1.02 DESCRIPTION OF WORK A. Construct sanitary sewer gravity

More information

PIPE REHABILITATION. Comply with Division 1 - General Provisions and Covenants, as well as the following:

PIPE REHABILITATION. Comply with Division 1 - General Provisions and Covenants, as well as the following: PIPE REHABILITATION PART 1 - GENERAL 1.01 SECTION INCLUDES A. Sliplining Pipe B. Cured-in-place Pipe Lining C. Deformed/Reformed Pipe Lining D. Folded/Formed Pipe Lining E. Spot Repairs by Pipe Replacement

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION ITEM 02514 MANHOLES 1.0 GENERAL 1.1 SCOPE This section provides for construction of sewer manholes complete in place, including the furnishing and adjusting to grade of an existing

More information

Canada s leader of complete geosynthetic solutions. HDPE Pipe Solutions. We offer complete solutions to all your piping needs.

Canada s leader of complete geosynthetic solutions. HDPE Pipe Solutions. We offer complete solutions to all your piping needs. Canada s leader of complete geosynthetic solutions HDPE Pipe Solutions We offer complete solutions to all your piping needs. Subdrains Corrugated HDPE Drainage Tubing terrafix subdrain pipe is used for

More information

PipeLine. Successful Design- Build WWTP Completed in Texas. October 2015, Issue 73

PipeLine. Successful Design- Build WWTP Completed in Texas. October 2015, Issue 73 October 2015, Issue 73 PipeLine Contents 1 I Successful Design-Build WWTP Completed in Texas 4 I Irrigation System for an Indian Reservation 7 I Product Profile: The HOBAS FWC Coupling 8 I Sign Up for

More information

7-0 SANITARY SEWER SYSTEMS

7-0 SANITARY SEWER SYSTEMS ADS, Inc. Drainage Handbook Sanitary Sewer Systems 7-1 7-0 SANITARY SEWER SYSTEMS TABLE OF CONTENTS 7-1 Overview of Sanitary Sewer Systems... 7-2 7-2 Sanitary Sewer Projects... 7-2 Preliminary Investigation...

More information

PVC Fittings & Laterals for Solid-Wall PVC Sewer Pipe

PVC Fittings & Laterals for Solid-Wall PVC Sewer Pipe Design and Installation Guide PVC Fittings & Laterals for Solid-Wall PVC Sewer Pipe TABLE OF CONTENTS Introduction 2 Products 3 Main-Line Fittings & Service-Line Fittings 3-4 Connections to Dissimilar

More information

SECTION GRAVITY WASTEWATER LINES

SECTION GRAVITY WASTEWATER LINES SECTION GRAVITY WASTEWATER LINES 1. DESCRIPTION This specification shall govern all work required for furnishing, handling and installing gravity wastewater lines required to complete the project. 2. MATERIALS

More information

F. Provide at least 2 feet of vertical separation between a water line and any utility or stormdrain crossing it.

F. Provide at least 2 feet of vertical separation between a water line and any utility or stormdrain crossing it. Section 3 F. Provide at least 2 feet of vertical separation between a water line and any utility or stormdrain crossing it. 3.8 Highway Crossings The design engineer shall, prior to the design of any highway

More information

Specification Guidelines for Testing and Sealing Lateral Connections and Lateral Service Lines in Sanitary Sewer Systems

Specification Guidelines for Testing and Sealing Lateral Connections and Lateral Service Lines in Sanitary Sewer Systems Specification The information contained in the document is property of Avanti International. Avanti offers the following verbiage as a technical reference to assist in the creation of specifications for

More information

50.20 Drainage Structure Design

50.20 Drainage Structure Design 50.20 Drainage Structure Design All drainage structures, with the exception of bridges, culvert bridges and, in some cases, culverts, shall be designed for HS20-44 loading. Refer to Section 50.22 for design

More information

Gasketed Sewer Pipe. Storm and Sanitary pipe for use with Gasketed Sewer Fittings.

Gasketed Sewer Pipe. Storm and Sanitary pipe for use with Gasketed Sewer Fittings. Gasketed Sewer Pipe Storm and Sanitary pipe for use with Gasketed Sewer Fittings. Gasketed Sewer Pipe Installation Royal Municipal Solutions Gasketed Sewer Pipe weighs a fraction of the weight of traditional

More information

San Antonio Water System Standard Specifications for Construction

San Antonio Water System Standard Specifications for Construction ITEM NO. 857 Fiberglass Reinforced Pipe for Large Diameter Gravity Sanitary Sewer 857.1 DESCRIPTION: This item shall govern the designing, fabricating, furnishing, installing, and joining of large dimeter

More information

ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES

ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES 853.1 DESCRIPTION: This item shall govern the construction of FRP sanitary sewer complete in place and the material therein,

More information

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II SECTION 221313 - FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

LARGE DIAMETER HDPE SLIPLINING WHERE EXPERIENCE MATTERS

LARGE DIAMETER HDPE SLIPLINING WHERE EXPERIENCE MATTERS LARGE DIAMETER HDPE SLIPLINING WHERE EXPERIENCE MATTERS Luis Aguiar Assistant Director Water Operations, Miami-Dade Water and Sewer Department Rafael Ortega President, Aurora Technical Services, LLC Robert

More information

CITY OF ODESSA SPECIAL SPECIFICATIONS ITEM 1000 GLASS-FIBER REINFORCED POLYESTER (FRP) REHAB/REPLACEMENT MANHOLE

CITY OF ODESSA SPECIAL SPECIFICATIONS ITEM 1000 GLASS-FIBER REINFORCED POLYESTER (FRP) REHAB/REPLACEMENT MANHOLE CITY OF ODESSA SPECIAL SPECIFICATIONS ITEM 1000 GLASS-FIBER REINFORCED POLYESTER (FRP) REHAB/REPLACEMENT MANHOLE 1000.1 DESCRIPTION These specifications shall govern the furnishing of glass-fiber reinforced

More information

Infiltration and Inflow. Michael Sassaman Phone

Infiltration and Inflow. Michael Sassaman Phone Infiltration and Inflow Michael Sassaman msassaman@entecheng.com Phone 610-373-3345 Inflow and Infiltration PA DEP Learning Objectives Do you have Excessive I/I? Sources of Inflow and Infiltration I/I

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES

San Antonio Water System Standard Specifications for Construction ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES 853.1 DESCRIPTION: This item shall govern the construction of FRP sanitary sewer complete in place and the material therein,

More information

Rowlett Cottonwood Transfer Sewer: 60" RCP Sanitary Sewer Rehabilitation Project. TACWA Meeting

Rowlett Cottonwood Transfer Sewer: 60 RCP Sanitary Sewer Rehabilitation Project. TACWA Meeting Rowlett Cottonwood Transfer Sewer: 60" RCP Sanitary Sewer Rehabilitation Project TACWA Meeting September 25, 2009 North Texas Municipal Water District Project Background 1. Rowlett-Cottonwood Transfer

More information

GWINNETT COUNTY STORM SEWER PIPE STANDARDS

GWINNETT COUNTY STORM SEWER PIPE STANDARDS 1.0 Standard Specifications GWINNETT COUNTY STORM SEWER PIPE STANDARDS 1.1 Unless otherwise specifically set forth herein or in the Gwinnett County Standard Drawings, all of the materials, methods of the

More information

Denlok Performance Advantages

Denlok Performance Advantages Jacking Strength (tons) 0.08 0.04 0.15 0.25 0.20 0.40 Inches 2.00 3.04 Denlok Performance Advantages Municipal Advantages Minimum 100 year life guarantee Demonstrated results from centuries of vitrified

More information

STIFPIPE : INTRODUCING A NEW HONEYCOMB-FRP PIPE

STIFPIPE : INTRODUCING A NEW HONEYCOMB-FRP PIPE STIFPIPE : INTRODUCING A NEW HONEYCOMB-FRP PIPE Mo Ehsani, PhD, PE, SE, F.ASCE President, PipeMedic, LLC and Professor Emeritus of Civil Engineering, University of Arizona, 2055 E. 17 th St.,Tucson, AZ

More information

Innovative Joint Proves Successful in Critical Slipline Project

Innovative Joint Proves Successful in Critical Slipline Project 644 Innovative Joint Proves Successful in Critical Slipline Project Tom Baas 1, Jeff Gardner 2, Richard Mielke 3 ABSTRACT Ever-tightening budgets are forcing water system owners to rehabilitate their major

More information

PIPE BURSTING SUCCESS

PIPE BURSTING SUCCESS GRUNDOCRACK PNEUMATIC PIPE BURSTING SYSTEM PIPE BURSTING SUCCESS STARTS HERE TT Technologies is the world leader in pipe bursting equipment and experience. For over 20 years contractors have relied upon

More information

Draft. Not Yet Approved SECTION 10.1 GENERAL SCOPE DEFINITIONS

Draft. Not Yet Approved SECTION 10.1 GENERAL SCOPE DEFINITIONS SECTION 10.1 GENERAL 10.1.1 SCOPE This part of the Manual covers the structural design and installation of reinforced concrete pipe for railway culverts. Pipe geometry may be circular, arch, or elliptical.

More information

PUBLIC WORKS DEPARTMENT GENERAL NOTES

PUBLIC WORKS DEPARTMENT GENERAL NOTES PUBLIC WORKS DEPARTMENT GENERAL NOTES 1. All construction shall be in strict accordance with the standards of the City of Southlake and governed by the North Central Texas Council of Government's Standard

More information

Multicell. Vikimatic MultiCell Conduit Systems MULTICELL

Multicell. Vikimatic MultiCell Conduit Systems MULTICELL Multicell Vikimatic MultiCell Conduit Systems These guidelines should help you install MultiCell Conduit in the simplest way possible and should be read in their entirety before attempting to install the

More information

FOX METRO WATER RECLAMATION DISTRICT MANHOLE / SEWER PIPE MATERIALS AND INSTALLATION SPECIFICATIONS MATERIALS 1. PIPE & FITTINGS

FOX METRO WATER RECLAMATION DISTRICT MANHOLE / SEWER PIPE MATERIALS AND INSTALLATION SPECIFICATIONS MATERIALS 1. PIPE & FITTINGS FOX METRO WATER RECLAMATION DISTRICT MANHOLE / SEWER PIPE MATERIALS AND INSTALLATION SPECIFICATIONS MATERIALS 1. PIPE & FITTINGS Rev: 3/26/18 Pipe and fittings used in sanitary sewer construction shall

More information

WASTEWATER REVIEW CHECKLIST. Project Number: Reviewed By: Telephone:

WASTEWATER REVIEW CHECKLIST. Project Number: Reviewed By: Telephone: The City of East Point DEPARTMENT OF WATER AND SEWER 1526 East Forrest Ave. Suite 400 East Point, Georgia 30344 FAX (404) 270-7215 www.eastpointcity.org WASTEWATER REVIEW CHECKLIST Project Name: Tax ID

More information

Index to Technical Specifications

Index to Technical Specifications Index to Technical Specifications Item Number Subject I II EXCAVATION 1.01 Trenching and Excavation Regulations 1.02 Site Grading or General Excavation 1.03 Structural Excavation 1.04 Trench Excavation

More information

CHAPTER 18: SANITARY SEWER SYSTEMS Introduction and Goals Administration Standards Standard Attachments 18.

CHAPTER 18: SANITARY SEWER SYSTEMS Introduction and Goals Administration Standards Standard Attachments 18. 18.00 Introduction and Goals 18.01 Administration 18.02 Standards 18.03 Standard Attachments 18.1 18.00 INTRODUCTION AND GOALS The purpose of this chapter is to provide guidance and outline specific standards

More information

SECTION 300 STORM SEWER TABLE OF CONTENTS

SECTION 300 STORM SEWER TABLE OF CONTENTS SECTION 300 STORM SEWER TABLE OF CONTENTS Starts on Page 300 GENERAL... 2 301 MATERIALS... 2 302 CONSTRUCTION PROCEDURES... 5 303 TESTING... 5 304 ABANDONMENT OF EXISTING STORM SEWER FACILITIES... 6 305

More information

TABLE OF CONTENTS

TABLE OF CONTENTS DIVISION 33: SEWER AND SEPTIC SYSTEMS 33 3633 UTILITY SEPTIC TANK DRAINAGE FIELD TABLE OF CONTENTS 33 0000-1 SECTION 33 3633-- UTILITY SEPTIC TANK DRAINAGE FIELD PART 1 - GENERAL 1.1 SUMMARY A. Includes

More information

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY Section Includes: 1. Pipe and fittings. 2. Drain Basin. 3. De-chlorination tablet feeder. 4. Non-pressure transition couplings.

More information

No-Dig Technology is the art and science of pipes, ducts and cables using techniques that minimizes / eliminates the need for excavation, i.e.

No-Dig Technology is the art and science of pipes, ducts and cables using techniques that minimizes / eliminates the need for excavation, i.e. No Dig Technology Introduction: No-Dig Technology is the art and science of installing, repairing or renewing underground pipes, ducts and cables using techniques that minimizes / eliminates the need for

More information

SECTION SANITARY SEWER SYSTEM

SECTION SANITARY SEWER SYSTEM SECTION 02731 SANITARY SEWER SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sanitary sewer system including necessary accessories indicated on drawings and specified in this section. Contractor

More information

Innovation Flows From Here

Innovation Flows From Here Innovation Flows From Here Superior Structural Strength and Value CANADA CULVERT has compiled years of research to manufacture an advanced, structurally superior corrugated steel pipe that will take on

More information

CITY OF ANAHEIM SEWER DESIGN MANUAL

CITY OF ANAHEIM SEWER DESIGN MANUAL CITY OF ANAHEIM CITY OF ANAHEIM DEPARTMENT OF PUBLIC WORKS SUBDIVISION SECTION SEWER DESIGN MANUAL TABLE OF CONTENTS 1. SIZING... 2 Design flows:... 2 Roughness coefficient (n):... 2 Velocity (Average

More information

PIPE BURSTING GRAVITY SEWER MAINS WITH HDPE PIPE

PIPE BURSTING GRAVITY SEWER MAINS WITH HDPE PIPE PIPE BURSTING GRAVITY SEWER MAINS WITH HDPE PIPE SUGGESTED STANDARD SPECIFICATION January, 2012 Prepared by International Pipe Bursting Association Thanks to the following participants for the development

More information

San Antonio Water System Specifications for Construction ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES

San Antonio Water System Specifications for Construction ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES 853.1 DESCRIPTION: This item shall govern the construction of FRP sanitary sewer manholes, complete in place and the materials

More information

DISPUTING THE MYTH OF INFLOW AND INFILTRATION REMOVAL EFFICIENCY

DISPUTING THE MYTH OF INFLOW AND INFILTRATION REMOVAL EFFICIENCY North American Society for Trenchless Technology (NASTT) NO-DIG 2005 Orlando, Florida April 24-27, 2005 DISPUTING THE MYTH OF INFLOW AND INFILTRATION REMOVAL EFFICIENCY Keith Cheek, Manager of Water Distribution

More information

CHAPTER 6. Sanitary Sewer

CHAPTER 6. Sanitary Sewer CHAPTER 6 Sanitary Sewer A. Introduction All proposed developments, subdivisions, and buildings must have a properly designed and constructed sanitary sewer collection system. The system shall provide

More information

INLINER LAY_InLiner Brochure_FA_ indd 1

INLINER LAY_InLiner Brochure_FA_ indd 1 INLINER LAY_InLiner Brochure_FA_010913.indd 1 Layne Inliner, LLC is the second largest cured-in-place pipe (CIPP) lining company in the United States. We began as the first U.S. licensee of the Inliner

More information

Pipe Bursting Services. pipe bursting. services

Pipe Bursting Services. pipe bursting. services Pipe Bursting Services pipe bursting services We have decades of experience solving the really big problems. Concern over the condition of the nation s infrastructure has caused government, municipalities,

More information

A-2000 PVC Pipe for Sanitary Sewers

A-2000 PVC Pipe for Sanitary Sewers ENGINEERED SOLUTIONS A-2000 PVC Pipe for Sanitary Sewers Engineered for Performance Manufactured by Contech Engineered Solutions, A-2000 represents the leading edge in sanitary sewer pipe technology with

More information

SECTION SANITARY SEWER SYSTEM

SECTION SANITARY SEWER SYSTEM SECTION 02530 SANITARY SEWER SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Section includes sanitary sewer system piping for collection of wastewater. B. Related Sections include but are not limited to: 1. Division

More information

SANITARY WASTE AND VENT PIPING

SANITARY WASTE AND VENT PIPING SECTION 15420 - SANITARY WASTE AND VENT PIPING PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

JACKING AWWA C300 AND C302 CONCRETE PRESSURE PIPE

JACKING AWWA C300 AND C302 CONCRETE PRESSURE PIPE 12 ACPPA TECHNICAL SERIES JACKING AWWA C300 AND C302 CONCRETE PRESSURE PIPE Jacking, including microtunneling, allows installation of pipe in deep covers, under existing infrastructure or in areas that

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 813 WATER SERVICE FOR FIRELINES

San Antonio Water System Standard Specifications for Construction ITEM NO. 813 WATER SERVICE FOR FIRELINES ITEM NO. 813 WATER SERVICE FOR FIRELINES 813.1 DESCRIPTION: This item shall consist of water service for fire line installations in accordance with these specifications and as directed by the Engineer.

More information

Cured-in-Place Pipe (CIPP) for Pressure Pipe. Presented by: Mike Moore

Cured-in-Place Pipe (CIPP) for Pressure Pipe. Presented by: Mike Moore Cured-in-Place Pipe (CIPP) for Pressure Pipe Presented by: Mike Moore CIPP Proven Technology Introduced over 45 years ago Most used trenchless technology for the rehabilitation of gravity flow pipeline

More information

SECTION 1 GENERAL NOTES

SECTION 1 GENERAL NOTES ISSUE DATE NOVEMBER 1st, 2011 SECTION 1 Page List Page Number Page Title COVER COVER GN-01 PAGE 1 GN-02 PAGE 2 GN-03 PAGE 3 GN-04 PAGE 4 GN-05 PAGE 5 GN-06 PAGE 6 GN-07 PAGE 7 : 1. (CCU) STANDARD SPECIFICATIONS

More information

PART II. - SPECIFICATIONS AND DESIGN STANDARDS TO CITY OF HEWITT, TEXAS SUBDIVISION ORDINANCE FOR PUBLIC WORKS CONSTRUCTION [TEXT]

PART II. - SPECIFICATIONS AND DESIGN STANDARDS TO CITY OF HEWITT, TEXAS SUBDIVISION ORDINANCE FOR PUBLIC WORKS CONSTRUCTION [TEXT] PART II. - SPECIFICATIONS AND DESIGN STANDARDS TO CITY OF HEWITT, TEXAS SUBDIVISION ORDINANCE FOR PUBLIC WORKS CONSTRUCTION [TEXT] A. - General. B. - Streets. C. - Stormwater drainage system. D. - Water

More information

LATEST DEVELOPMENTS INCREASE THE CAPABILITIES OF SPIRAL WOUND LINERS

LATEST DEVELOPMENTS INCREASE THE CAPABILITIES OF SPIRAL WOUND LINERS LATEST DEVELOPMENTS INCREASE THE CAPABILITIES OF SPIRAL WOUND LINERS John Monro, Interflow Pty Limited ABSTRACT For many years spiral wound liners have been the most used type of liner for the rehabilitation

More information

7. Allowable Fittings.

7. Allowable Fittings. 7. Allowable Fittings. a. General Requirements. 1) The fittings listed in this section are generally the allowable fittings for the design of DIP and PVC pipe. For steel pipe and fittings, see Part One,

More information

A. This Section includes gravity-flow, nonpressure storm drainage outside the building, with the following components:

A. This Section includes gravity-flow, nonpressure storm drainage outside the building, with the following components: SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.I RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Sliplining 36-in. PCCP with Fusible PVC - DC Water's Long-Term Control Plan 'Division E'

Sliplining 36-in. PCCP with Fusible PVC - DC Water's Long-Term Control Plan 'Division E' North American Society for Trenchless Technology (NASTT) NASTT s 2014 No-Dig Show Orlando, Florida April 13-17, 2014 Paper MA-T4-02 Sliplining 36-in. PCCP with Fusible PVC - DC Water's Long-Term Control

More information