Thermo Scientific BioLC Columns. Innovative solutions for mab analysis and characterization

Size: px
Start display at page:

Download "Thermo Scientific BioLC Columns. Innovative solutions for mab analysis and characterization"

Transcription

1 Thermo Scientific BioLC Columns Innovative solutions for mab analysis and characterization

2 Table of Contents Biopharma Terminology Introduction to Monoclonal Antibody (mab) Characterization Biopharma Workflows Routine Screening and Clone Selection Intact mab Profiling and Subunit Analysis High Resolution Peptide Mapping Glycan Analysis Workflow Affinity Titer Determination Aggregate Separation Charge Variant Analysis Salt Gradient Method ph Gradient Method Oxidation Variant Analysis Antibody Drug Conjugates (ADCs) Analysis HIC Separation RP Separation Intact mab and mab Fragment Analysis Peptide Mapping Glycan Analysis Application Notes Selected Publications Ordering Information Biopharmaceutical Markets

3 Biopharma Terminology Term Discovery Development Clinical/pre-clinical Commercialization FDA What does it mean? Process to identify and screen potential drug compounds. Investigate the most effective compounds from discovery phase; determine efficacy, lifetime, and potential side-effects. Clinical trials with human volunteers performed in medical clinics and hospitals. Phase when a new drug achieves legislative success, passes regulatory requirements, and is launched to market. Food and Drug Administration, responsible for licensing and control of pharmaceuticals in the US. EMA European Medicines Agency. CFDA Monoclonal Antibody/mAb Biosimilar Isoelectric point (pi) Charge variants Glycan Aggregates China Food and Drug Administration. A protein biologic that has been engineered to target certain cells. Many new pharmaceutical products are mabs. A biological product that is demonstrated to be highly similar to an FDA-licensed biological product (the reference product). The ph at which the overall net charge of a protein in zero. Variations in the mab amino acid sequence and modifications that lead to alterations in the overall net charge. Acidic charge variants arise from modification such as deamidation and sialylation, (which give increased net negative charge). Basic charge variants result from the presence of C-terminal lysine or glycine amidation, succinimide formation, amino acid oxidation or removal of sialic acid, (which introduce additional positive charge). A carbohydrate/sugar. The quantity and location of glycans on a protein can influence the efficacy of the drug. Clusters of mab units that form due to two or more drug compounds attaching to each other. Peptide Antibody-Drug Conjugate (ADC) DAR (Drug-to-Antibody Ratio) Short chain molecules of multiple amino acids that form the larger protein structure. A mab chemically coupled to a linker and cytotoxic drug. ADCs are a class of therapeutics that harness the antigen-selectivity of mabs to deliver highly potent cytotoxic drugs to antigen-expressing tumor cells. The use of mab directed delivery increases both the efficacy and safety of therapy. The ratio of the number of cytotoxic drug linkers per mab unit present in an ADC. Titer PTM Quantitation of therapeutic mab present in the cell culture. Post-translational modification. A change in an amino acid residue side-chain due to an enzymatic or chemical process. 3

4 Introduction to Monoclonal Antibody (mab) Characterization Protein and monoclonal antibody (mab) biopharmaceuticals form a major part of the growing biologics drug market, and have been transforming the biotechnology and biopharmaceutical industries in the last decade. mab treatment is amongst the most effective methods of diagnosis and treatment of a broad range of diseases, including autoimmune disorders, cardiovascular diseases, infectious diseases, cancer and inflammation. There is an extensive development pipeline for protein and mab therapeutics, further emphasizing the need for innovative and efficient analytic tools. During development and production of these products it is essential to detect, characterize and quantify structural variants and modifications and to monitor product stability. This is key to demonstrating safety and efficacy and is required by the U.S. FDA, EMA, CFDA and other regulatory agencies. Highlighted in the table below are the various LC and LC-MS protein analytical chemistry methods used in the testing of biological products, as well as the recommended bio-columns and buffers. Analysis Description Columns and Buffers mab Capture and Titer Analysis mab titer determination (concentration) & screening; mab capture for analysis workflows Thermo Scientific MAbPac Protein A POROS A, Cartridge Aggregate Analysis routine screening for mab aggregates and fragments MAbPac SEC-1 MAbPac HIC-1 MAbPac HIC-2 Thermo Scientific Acclaim SEC-3 Charge Variant Analysis routine charge variant profiling/screening, including lysine truncation,deamidation & acylation; Methionine & Tryptophan Oxidation targeted analysis of methionine and tryptophan oxidation MAbPac HIC-2 MAbPac HIC-1 ProPac HIC-1 Antibody Drug Conjugates (ADCs) Analysis ADC Drug-to-Antibody Ratio (DAR) DAR analysis MAbPac HIC-Butyl MAbPac HIC-1 MAbPac HIC-2 MAbPac RP Intact mab & Fragments Analysis Sequence & Structural Analysis light chain (LC) and heavy chain (HC) analysis; Fab and Fc analysis; scfc and F(ab') 2 analysis primary sequence analysis; peptide mapping; peptide & glycopeptide structural & linkage analysis MAbPac SCX-1 MAbPac SCX-1RS Thermo Scientific ProPac WCX-1 Thermo Scientific CX-1 ph Gradient Buffer Kit MAbPac RP Thermo Scientific ProSwift RP-1S MAbPac SEC-1 MAbPac HIC-2 Acclaim RSLC 12 C18 Acclaim 3 C18 Thermo Scientific Accucore 15-C18 Glycan Profiling profiling of released glycans Thermo Scientific GlycanPac AXH-1 GlycanPac AXR-1 Accucore 15-Amide-HILIC 4

5 Heavy Chain Antigen-binding site V H V H F ab V L C H 1 C H 1 V L Pyroglutamate formation from glutamine or glutamic acid Light Chain C L C L Asparagine deamidation Aspartic acid isomerization C H 2 C H 2 Glycosylation F c C H 3 C H 3 Methionine oxidation Lysine truncation K K Reduction of disulfide bond or disulfide shuffling Monoclonal antibodies have very complex structures, with many possible site-specific variations. With such potential for post translational modifications (PTMs), quality control and stability assessment of monoclonal antibodies are very challenging tasks. High pressure liquid chromatography has established itself as an essential tool in the characterization of mab and other protein biotherapeutics. 5

6 Biopharma Workflows Routine Screening and Clone Selection Workflow In the early development stage, purification of mab or IgG from harvested cell culture fluid (HCCF) using Protein A is typically the first step. Often this is followed by size-exclusion chromatography (SEC) for aggregate profiling and ionexchange chromatography (IEC) for charge variants analysis. Therefore, these separation modes make up a substantial portion of the analysis performed during mab development. Protein A Capture of IgG Fraction Collection & Neutralization Aggregate analysis by SEC Charge variant analysis by IEC: salt or ph gradient s Intact mab Profiling and Subunit Analysis Workflow Intact mab analysis provides information such as molecular weight, drug-antibody ratio (DAR), and glycan profiles. mab fragment analysis can quickly pinpoint the location of the modifications without complete digestion of the mab. MAb light chain (LC) and heavy chains (HC) are generated by the reduction of the four inter disulfide bonds. Papain cleaves above the hinge region containing the disulfide bonds that join the heavy chains, but below the site of the disulfide bond between the light chain and heavy chain. This generates two Fab fragments and an intact Fc fragment. The Immunoglobulin-degrading enzyme from Streptococcus pyogenes (IdeS) is a highly specific protease that cleaves Immunoglobulin G (IgG) at a single site below the hinge region, yielding single chain Fc (scfc) and F(ab') 2 fragments. This is also known as the middle-down approach. Optional in-depth analysis of variants and sequence can be performed by MS n (multiple stages of MS). Reduction, Papain Digestion, IdeS Digestion LC, HC, Fc, Fab, scfc, F(ab')2 separation by RP-HPLC High Resolution Accurate Mass (HRAM) MS MS-MS & MS n s High Resolution Peptide Mapping Workflow A thorough mab sequence analysis is achieved by trypsin digestion and analysis of the tryptic peptides by LC-MS/MS using a reversed phase C18 separation. Peptide mapping is commonly used to identify modifications of amino acids, such as deamidation and oxidation. Structural analysis is usually carried out using a high resolution mass spectrometer during the development stage. However, for routine QC batch release, peptide separations are monitored by UV. Trypsin Digestion Desalting by RP Media Peptide Mapping by RPLC Peptide Analysis by Mass Spec s 6

7 Glycan Analysis Workflow The workflow below shows the most common ways to analyze glycans structures and glycosylation sites. PNGase F is a endoglycosidase cleaving the link between asparagine and N-acetylglucosamines. After PNGase F digestion, the N-linked carbohydrates are released from the mab and analyzed by either an IC or HPLC methods. For glycosylation site identification, tryptic digestion is often performed and the glycopeptides are analyzed by LC-MS method. For biological product QC testing, intact mab can be analyzed using a high resolution mass spectrometer. This analysis provides accurate molecular weight and glycan profile information. Digestion to monosaccharides Release of glycans by PNGase F digestion Tryptic digestion to glycopeptides Intact mab Sugar and sialic acid analysis by IC or HPLC Glycan profiling by IC or HPLC Structure and site analysis by LC/MS High Resolution Accurate Mass (HRAM) MS s s s s The Complete Solution A combination of these separation workflows allows users to achieve a wide range of analytical tasks, such as: Purity and titer analysis Aggregation analysis Charge variant analysis Clips and truncations Light chain/heavy chain analysis Peptide mapping Glycan profiling Post-translational modification analysis (amino acid substitutions/truncations, deamidation, phosphorylation, etc.) We offer a complete solution for each of the workflows, enabling scientists to achieve optimum and reliable results. 7

8 Affinity Titer Determination Early in the development of recombinant mabs, a large number of harvest cell culture (HCC) samples must be screened for IgG titer, i.e. various antibody epitopes must be quantified. The high degree of specificity offered by affinity chromatography provides a powerful alternative to established immunoaffinity methods such as ELISA. Protein A ligand is often used due to its strong affinity to bind a wide range of antibodies. The MAbPac Protein A HPLC affinity column can be used to determine the MAb concentration in HCC. Unbound Column: MAbPac Protein A 5,2 4 Format: mm 4, Area,mAu.min R 2 =.9998 Eluent A: Eluent B: 5 mm sodium phosphate, 15 mm sodium chloride, 5% acetonitrile, ph mm sodium phosphate, 15 mm sodium chloride, 5% acetonitrile, ph 2.5 mau 3, 2, 1, IgG Amount rabbit IgG, μg Gradient: Flow Rate: % B for.2 mins, 1% B for.6 mins, % B for 1.2 mins 2 ml/min Inj. Volume: 1 µl Temp.: 25 ºC Detection: 28 nm Sample: Harvest cell culture (HCC) Minutes The challenge faced by analytical laboratories in the pharmaceutical industry is to the development of a high-throughput and robust titer assay. The MAbPac Protein A column has been engineered specifically for this application from a novel polymeric resin with a hydrophilic surface, covered with a covalently bound recombinant Protein A. The hydrophilic nature of the backbone minimizes nonspecific binding, and therefore enables accurate quantification of the mab titer. The MAbPac Protein A column format allows rapid automation of loading, binding, elution and collection using the biocompatible HPLC system, such as the Thermo Scientific UltiMate 3 BioRS system. MAbPac Protein A columns feature excellent binding efficiency, high loading capacity, and superior ruggedness. Lower backpressure enables fast analysis. A simple step gradient from near-neutral to acidic ph is all that is required to elute the bound material. mau 1,4 1,2 1, Column: Format: Eluent A: Eluent B: Gradient: Flow Rate: MAbPac Protein A mm 5 mm sodium phosphate, 15 mm sodium chloride, 5% acetonitrile, ph mm sodium phosphate, 15 mm sodium chloride, 5% acetonitrile, ph 2.5 % B for.2 mins, 1% B for.6 mins, % B for 1.2 mins 2 ml/min Inj. Volume: 2 µl Temp.: 25 ºC Detection: Sample: 28 nm Rabbit IgG, 1 mg/ml Minutes t R (min) Area (mau*min) PWHH (min) Average % RSD

9 Aggregate Separation Monoclonal antibodies (mabs) produced from mammalian cell culture may contain significant amounts of dimers and higher-order aggregates. Studies show that these aggregates present in drug products may result in enhanced desired response, but may also cause severe immunogenic and anaphylactic reactions. Thus, biopharmaceutical manufacturers are required to develop analytical methods to monitor size heterogeneity and control levels of dimer and higher-order aggregates. a b c mau mau mau μg Aggregates min mab monomer μg 125 mab monomer 1 75 Aggregates μg mab monomer Aggregates Column: Format: MAbPac SEC-1, 5 µm, a mm b mm a mm Mobile Phase: 5mM sodium phosphate ph 6.8, in 3 mm sodium chloride Flow Rate: a. 76 µl/min b. 2 µl/min c. 5 µl/min Inj. Volume: a. 1 µl b. 5 µl a. 1 µl Temp.: 3 ºC Detection: Sample: 28 nm mab (1 mg/ml) Size-exclusion chromatography (SEC) is an ideal choice for separation for mab aggregates. For SEC the separation is based solely on the size of the molecule which does not interact with the stationary phase. Molecules of different sizes penetrate the pores to varying extents. This results in analytes of different sizes travelling through the media at different speeds. Larger molecules do not diffuse deep in the pores and elute first, whilst smaller entities diffuse deeper in the pores and elute later. The MAbPac SEC-1 column is specially designed for the separation and characterization of monoclonal antibodies (mabs), their aggregates, and analysis of Fab and Fc fragments. The MAbPac SEC-1 column is based on high-purity, spherical, porous (3 Å), 5 μm silica particles that are covalently modified with a hydrophilic layer, resulting in an extremely low level of undesired interaction sites. The stationary phase is designed to handle different eluent conditions containing both high and low ionic strength mobile phases, as well as mass spectrometry friendly volatile eluents. The three different column formats meet different analytical needs: the 7.8 mm ID column provides the highest resolution separation and accurate quantitation of mabs and their aggregates; the 4. mm ID column enables baseline separation of mab monomer and dimer, requiring only ¼ of sample compared to the 7.8 mm ID column; the 2.1 mm ID column uses low flow rate and low sample loading, making it the perfect format for MS detection. 9

10 Charge Variant Analysis Ion Exchange Chromatography (IEC) is based on a stationary phase with a charged ligand on the surface interacting with analytes of the opposite charge. The technique is divided between anion exchange and cation exchange chromatography. In anion exchange, positively charged surface ligands interacts with negatively charged analytes, whilst in cation exchange negatively charged surface ligands interact with positively charged analytes. Salt Gradient Method In salt gradient-based IEC, the ph of the buffer is fixed. In addition to choosing the appropriate ph of the starting buffer, the initial ionic strength is kept low since the affinity of proteins for IEC resins decreases as ionic strength increases. The proteins are then eluted by increasing the ionic strength (salt concentration) of the buffer to increase the competition between the buffer ions and proteins for charged groups on the IEC resin. As a result, the interaction between the IEC resin and proteins is reduced, causing the proteins to elute. The pi of the majority of antibodies tends to be in the ph 6 1 region, which is the reason why cation exchange is the commonly chosen separation method for mab charged variants. A range of cation exchange columns, such as the MabPac SCX-1 column family, is available and designed specifically for the separation of mab variants and other variations affected by charge, such as lysine truncation variants mau Sample 1 Sample Minutes Column: MAbPac SCX-1, 1 µm Format: mm Mobile Phase A: 2 mm MES, 6 mm sodium chloride, ph 5.6 Mobile Phase B: 2 mm MES, 3 mm sodium chloride, ph 5.6 Gradient: 15 36%B in 5 min. Flow Rate: 1. ml/min Inj. Volume: 5 µl Temp.: 3 ºC Detection: UV (28 nm) Sample: 1: mab (9 mg/ml) 2: mab (9 mg/ml) + carboxypeptidase B (CPB) Peaks: Sample 1 1 5: Acidic variants 6 8: C-terminal lysine truncation variants of the main peak 9 11: C-terminal Lys truncation variants of a minor variant peak Sample 2 6: From peaks 6, 7, 8 after CPB treatment 7: From peaks 9, 1, 11 after CPB treatment 1

11 ph Gradient Method In ph-gradient-based IEC, the starting buffer is held at a constant ph to ensure the proteins have a charge opposite to the stationary phase, thus binding to the column. As the gradient runs, the ph of the buffer is changed so the proteins transition to a net zero charge (the pi), and ultimately the same charge as the resin, thus the protein is released and eluted from the column. + Cation-Exchange (Buffer ph < pi) 2 Isoelectric Point (pi) Net charge = Protein net charge is negative - interact with positively charged surface Buffer ph Anion-Exchange (Buffer ph > pi) Protein net charge is negative - interact with positively charged surface Protein net charge vs. ph In the fast-paced drug development environment, a platform method to accommodate the majority of MAb analyses is desired. Considerable effort is often required to tailor the salt gradient method for a cation exchange separation of an individual mab. Ion exchange separations by ph gradient provide the advantage of a generic platform approach, thus saving time on method development. 11

12 One of the challenges in ph-gradient separations is choosing a buffer system able to cover a wide ph range whilst delivering a linear ph gradient. We offer a novel ph gradient method for cation-exchange chromatography. This method features a multi-component zwitterionic buffer system in which the linear gradient can be run from 1% eluent A (low ph buffer) to 1% eluent B (high ph buffer). The linearity of the ph gradient can be verified using a Thermo Scientific Dionex UltiMate PCM-3 ph and conductivity online monitor, which is easily incorporated with Thermo Scientific LC instrumentation. Once the approximate ph elution range of the target mab has been established in the initial run, optimization of the separation is achieved by running a shallower ph gradient over a narrower ph range. Separation of avastin/bevacizumab variants is optimized using a ph gradient. When a broad ph gradient is applied from % to 1% B (ph 5.6 to 1.2), all variants are eluted in the ph range 7. to 8.. Adjusting the gradient to 5% B ( ph range, middle), resolution is further improved with minimal optimization steps. For comparison, avastin/bevacizumab variants separation by the salt gradient methods with a steeper (a) and a shallower gradient slope (b). a Avastin ph Gradient 1% B Absorbance (mau) b Avastin ph Gradient 5% B Absorbance (mau) c Avastin Salt Gradient 1% B Absorbance (mau) d Avastin Salt Gradient 5% B Absorbance (mau) Retention Time (min) Retention Time (min) Retention Time (min) Retention Time (min) Column: Format: MAbPac SCX-1, 1 μm mm Mobile Phase A: 1X CX-1 ph gradient buffer A, ph 5.6 Mobile Phase B: 1X CX-1 ph gradient buffer B, ph 1.2 ph Gradient: Flow Rate: Inj. Volume: % B to 1% B from 1 to 31 min 1. ml/min 5 μl Temp.: 3 ºC Detection: Sample: Column: Format: UV (28 nm) Avastin/bevacizumab (1 mg/ml) MAbPac SCX-1, 1 μm mm Mobile Phase A: 1X CX-1 ph gradient buffer A, ph 5.6 Mobile Phase B: 1X CX-1 ph gradient buffer B, ph 1.2 ph Gradient: Flow Rate: Inj. Volume: % B to 5% B from 1 to 31 min 1. ml/min 5 μl Temp.: 3 ºC Detection: Sample: Column: Format: Mobile Phase A: Mobile Phase B: Salt Gradient: Flow Rate: Inj. Volume: UV (28 nm) Avastin/bevacizumab (1 mg/ml) MAbPac SCX-1, 1 μm mm 2 mm MES (ph 5.6) + 6 mm sodium chloride 2 mm MES (ph 5.6) + 3 mm sodium chloride % B to 1% B from 1 to 31 min 1. ml/min 5 μl Temp.: 3 ºC Detection: Sample: Column: Format: Mobile Phase A: Mobile Phase B: Salt Gradient: Flow Rate: Inj. Volume: UV (28 nm) Avastin/bevacizumab(1 mg/ml) MAbPac SCX-1, 1 μm mm 2 mm MES (ph 5.6) + 6 mm sodium chloride 2 mm MES (ph 5.6) + 3 mm sodium chloride % B to % B from 1 to 31 min 1. ml/min 5 μl Temp.: 3 ºC Detection: Sample: UV (28 nm) Avastin/bevacizumab (1 mg/ml) 12

13 In order to push the throughput of the charge variant assay, fast separation of mab variants is achieved using a 5 µm MAbPac SCX-1 RS column with a Thermo Scientific Vanquish UHPLC system. The Vanquish UHPLC system is fully biocompatible, suitable for the analysis of intact proteins. The combination of low gradient delay volume and high precision gradient formation makes it the ideal system for high throughput analysis with gradient elution. An example shown here is an ultra fast separation of infliximab variants separated using ph gradient and a MAbPac SCX-1 RS column (5 μm, mm). mau a b min 4 5 Column: MAbPac SCX-1 RS, 5 µm Format: mm Mobile Phase A: 1X CX-1 ph gradient buffer A, ph 5.6 Mobile Phase B: 1X CX-1 ph gradient buffer B, ph 1.2 ph Gradient: a. 2% B to 4% B in 5 min b. 18% B to 27% B in.8 min Flow Rate: a..5 ml/min b. 1.2 ml/min Inj. Volume: 4 µl Temp.: 3 ºC Detection: UV (28 nm) Sample: Infliximab (1 mg/ml) The linearity of the ph gradient can be verified using the UltiMate 3 ph and conductivity online monitor, which can be added to UltiMate 3 BioRS system to serve as a platform for ph gradient ion exchange chromatography. The UltiMate 3 ph and conductivity monitor is a valuable tool for HPLC method development, particularly for protein and nucleic acid separations. It enables linking the mobile phase ph and/or conductivity with the elution time of the components. The ph and conductivity monitor allows for the monitoring of gradient formation, column equilibration, and understanding column buffering effects in ph gradient ion-exchange chromatography. Absorbance (mau) Lectin Lectin Lectin Trypsinogen Retention Time (min) Ribonuclease A Cytochrome C Column: MAbPac SCX-1, 1 μm Format: mm Mobile Phase A: 1X CX-1 ph gradient buffer A, ph 5.6 Mobile Phase B: 1X CX-1 ph gradient buffer B, ph 1.2 ph Gradient: Time (min) %A %B Flow Rate: 1. ml/min Inj. Volume: 5 μl Temp.: 3 ºC Detection: UV (28 nm) Sample: Protein Standard Measured ph value Lectin-3 Lectin-2 Lectin-1 y = x R2 =.9929 Trypsinogen Ribonuclease A Measured ph Linear (Measured ph) Cytochrome C pi Value Monitoring the eluent ph during a ph gradient makes charge variant characterization more simple and predictable because proteins will only elute once the eluent ph is above the biomolecules pi. The measured ph values for six protein peaks (lentil lectin-1, lectin-2, lectin-3, trypsinogen, ribonuclease A, and cytochrome C), exhibit a strong linear correlation to the literature based pi values. This shows that the pi of a protein component can be estimated based on the peak retention time and measured ph. 13

14 Oxidation Variant Analysis Hydrophobic Interaction Chromatography (HIC) is an important tool for protein chemists separating proteins under gentle, non-denaturing conditions. Biomolecules are separated by their degree of hydrophobicity. The mobile phase consists of a salting-out agent, which at high concentration retains the protein by increasing the hydrophobic interaction between proteins and the stationary phase. The bound proteins are eluted by decreasing the salt concentration. Since proteins are relatively stable in the salt solutions used as the mobile phase, the biological activity of proteins is usually maintained in HIC. This makes HIC separations ideal for high resolution analyses as well as a purification step or polishing prior to analysis. Oxidation of exposed amino acid residues such as methionine (Met) and tryptophan (Trp) is a major concern in therapeutic mab stability studies. Oxidation of amino acid residues on a mab can alter the hydrophobic nature of the mab by either an increase in polarity of the oxidized form or a conformational change. This can also have an effect on the activity of the therapeutic. Therefore hydrophobicity-based HPLC methods such as reversed-phase chromatography and hydrophobic interaction chromatography are often used to characterize oxidized mab products. The MAbPac HIC-2 column is a high-resolution silica-based HIC column designed for the separation of mabs and mab variants. Its unique column chemistry provides high resolution, rugged stability and desired selectivity for mab and mab variants. MAbPac HIC-2 provides superior resolution of oxidized mab variants from unmodified mab. The MAbPac HIC-2 can resolve oxidized mab variants without fragmentation or other sample preparation. Absorbance (mau) Oxidized variants Native mab Retention Time (min) Column: MAbPac HIC-2, 5 µm Format: Mobile Phase A: mm 2 M ammonium sulfate, 1 mm sodium phosphate, ph 7. Mobile Phase B: 1 mm sodium phosphate, ph 7. Gradient: Time (min) %A %B Flow Rate: Inj. Volume: Temp.: 3 ºC Detection: Sample: ml/min Untreated mab: 2 µl (1.25 mg/ml) Oxidized mab: 2 µl (1.25 mg/ml) UV (28 nm) Untreated mab H 2 O 2 oxidized mab 14

15 Antibody-Drug Conjugate (ADC) Analysis ADCs have gained tremendous interest among pharmaceutical companies due to their significantly improved clinical efficacy over native monoclonal antibodies. The conjugation of drugs often results in an ADC molecule that is heterogeneous with respect to both the distribution and loading of cytotoxic drugs on the mab. The number of drugs attached to the mab has been shown to directly affect the safety and the efficacy of the drug. Therefore it is critical to fully characterize and monitor the heterogeneity of ADCs during development and production. Hydrophobic interaction chromatography (HIC) and reversed-phase chromatography (RPC) are suitable for the separation of ADCs since attachment of toxic drugs alters the hydrophobicity of the antibody. Typically the least hydrophobic unconjugated antibody elutes first and as the number of drugs attached increases the elution time increases. ADC Analysis by Hydrophobic Interaction Chromatography The MAbPac HIC-Butyl column is based on hydrophilic, non-porous, 5 µm polymer particles functionalized with butyl groups. The hydrophilic resin provides biocompatibility while the optimal density of the butyl groups provides high resolution separation. An ADC mimic sample was analyzed using a MAbPac HIC-Butyl column. The ADC mimics were conjugates between a drug mimic and a mab via the sulfhydryl group of interchain cysteine residues which results in a mixture of drug-loaded antibody species with to 8 drugs. The unmodified mab and ADCs with DAR (drug-to-antibody ratio) values ranging from 2 to 8 are well resolved by the MAbPac HIC-Butyl column. a Reduction of interchain disulfide bonds Thiol-specific drug conjugation mab Cys-conjugated ADC = Heavy Chain = Light Chain = Drug b Absorbance (mau) DAR DAR 2 DAR 4 DAR 6 Retention Time (min) DAR Column: MAbPac HIC-Butyl, 5 µm Format: Mobile Phase A: Mobile Phase B: mm 1.5 M ammonium sulfate, 5 mm sodium phosphate, ph 7./isopropanol (95:5 v/v) 5 mm sodium phosphate, ph 7./isopropanol (8:2 v/v) Gradient: Time (min) %A %B Flow Rate: Inj. Volume: Temp.: 25 ºC Detection: Sample: ml/min 5 µl (5 mg/ml) UV (28 nm) Cys-conjugated ADC mimic 15

16 ADC Analysis by Reversed-Phase Chromatography The MAbPac RP column is based on supermacroporous 4 µm polymer particles. The hydrophobic phenyl based resin with its large pore size enables efficient separation of large molecules including mabs and their conjugates. Shown in the chromatogram below is an ADC created using site-specific antibody labeling technology and analyzed using a MAbPac RP column. ADCs were prepared by enzymatically activating mab Fc domain glycans with azides using the mutant beta-galactosyltransferase enzyme. The azide-activated antibodies were then conjugated with dibenzocyclooctyne (DIBO) -activated Val-Cit-PAB-Monomethyl Auristatin E (MMAE) toxin resulting in a mixture of drug-loaded antibody species with to 4 MMAE molecules. The unmodified mab and ADCs with DAR values ranging from to 4 are well resolved by the MAbPac RP column. a ß-1,4- Galactosidase Add in GalT(Y289L) UDP-GalNAz DIBO-MMAE N 3 N 3 N 3 N 3 37 C, 5 hr 37 C, ON 25 C, ON MMAE MMAE MMAE MMAE Unlabeled Ab Cleave Terminal Gal Azide-Activated Ab (stable for long-term storage) Antibody Drug Conjugate (ADC) b 25. Column: MAbPac RP, 4 µm Format: mm Absorbance (mau) DAR DAR1 DAR2 & DAR Retention Time (min) DAR4 Mobile Phase A: Mobile Phase B: Water/trifluoroacetic acid (99.9 :.1 v/v) Acetonitrile/water/trifluoroacetic acid (9: 9.9 :.1 v/v/v) Gradient: Time (min) %A %B Flow Rate: Inj. Volume: 2 µl Temp,: 8 ºC Detection: Sample: ml/min UV (28 nm) Trastuzumab-MMAE 16

17 Intact mab and mab Fragments Analysis In order to verify the quality attributes of the overall molecule, and to provide a reproducible, safe and effective biological drug compound, the correct protein sequence as well as the presence and relative abundance of different glycoforms must be confirmed. The simplest way to achieve this is to interface the separation with high resolution MS/MS detection. Typically, mabs are analyzed in either their native intact form, in reduced light/heavy chain form, or after enzymatic cleavage into antigen binding fragment (Fab) and crystallizable fragment (Fc). Reversed-phase chromatography has been used for many years as an excellent interface with MS detection. The low concentrations of volatile buffers component combined with the high organic make-up of the mobile phase result in conditions ideal for stable and effective spray. Furthermore, the separation principle offers an alternative selectivity based on hydrophobicity, which provides orthogonal high-resolution separations to ion-exchange method. MAbPac RP uses supermacroporous resin which has large pore size and high loading capacity. This feature has an ideal benefit in antibody analysis, due to the large size of the protein (typical MW of 15 kda). The excellent performance of the MAbPac RP HPLC columns for mab fragment analysis is shown here for the analysis of trastuzumab fragments: LC and HC, Fc and Fab, scfc and F(ab') 2 are baseline separated using a 1-min gradient. 14 (a) Trastuzumab mab -2 8 (b) Trastuzumab + DTT HC 5 LC DTT Reduction Absorbance (mau) (c) Trastuzumab + Papain Fc Fab Papain digestion F ab F ab F c LC IgG HC -1 1 (d) Trastuzumab + IdeS F(ab') 2 F (ab') 2 5 scfc IdeS IgG scfc Retention Time (min) Column: MAbPac RP, 4 µm Format: Mobile Phase A: Mobile Phase B: 3. 5 mm Water/formic acid/trifluoroacetic acid (99.88:.1:.2 v/v/v) Acetonitrile/water/formic acid/ trifluoroacetic acid (9: 9.88:.1:.2 v/v/v/v) Gradient: Time (min) %A %B Flow Rate:.5 ml/min Inj. Volume: 5 µl Temp.: 8 ºC Detection: UV (28 nm) Sample: (a) Trastuzumab (5 mg/ml) (b) Trastuzumab + DTT (4 mg/ml) (c) Trastuzumab + Papain (2 mg/ml) (d) Trastuzumab + IdeS (2 mg/ml) 17

18 The reversed-phase chromatographic analysis can be coupled to high-resolution mass spectrometry systems to confirm the accurate molecular weight of the target product and identify variants. Here is an example of LC-MS analysis of trastuzumab using a Thermo Scientific Q Exactive Plus hybrid quadrupole-orbitrap mass spectrometer. The top trace shows the total ion chromatogram and the bottom trace shows the mass spectrum TIC 8.26 Relative Abundance Relative Abundance MS spectrum Time (min) m/z See detail below Detail area from above m/z at Relative Abundance m/z Column: MAbPac RP, 4 µm Format: Mobile Phase A: Mobile Phase B: 3. 5 mm Water/formic acid/trifluoroacetic acid (99.88:.1:.2 v/v/v) Acetonitrile/water/formic acid/ trifluoroacetic acid (9:9.88:.1:.2 v/v/v/v) Gradient: Time (min) %A %B Flow Rate:.5 ml/min Inj. Volume: 1 µl Temp.: 8 ºC MS Detection: positive-ion mode Mass Spec: Q Exactive Plus Sample: Trastuzumab (5 mg/ml) 18

19 Further structural elucidation is obtained by reducing the trastuzumab into light chain and heavy chain fragments. Interface with Q Exactive Plus mass spectrometer allows the identification of different glycoforms in the heavy chain as shown below TIC LC 7.43 HC 8.28 Relative Abundance UV Time (min) Relative Abundance LC Relative Abundance HIC m/z Relative Abundance m/z

20 Methionine (Met) oxidation is one of the critical quality attributes required to be closely monitored. The two Met residues in the CH2-CH3 domain interface of recombinant humanized and fully human IgG1 antibodies were found susceptible to oxidation. It is desirable to monitor the progress of the Met oxidation without complete digestion of mab. A workflow was designed to first reduce mab and then further digest it with IdeS resulting in smaller (25 kda) fragments. Further digestion of the HC by IdeS resulted in two smaller fragments: scfc and Fd'. The MAbPac RP baseline separates scfc, LC, and Fd' fragments as shown below. The +1 charge state of the oxidized scfc and non-oxidized scfc are at m/z and at m/z Relative Abundance Relative Abundance Fd 1 LC Oxidizied scfc scfc TIC Oxidized scfc scfc Time (min) m/z Column: MAbPac RP, 4 µm Format: Mobile Phase A: Mobile Phase B: 3. 5 mm Water/formic acid/trifluoroacetic acid (99.88 :.1:.2 v/v/v) Acetonitrile/water/formic acid/ trifluoroacetic acid (9: 9.88 :.1:.2 v/v/v/v) Gradient: Time (min) %A %B Flow Rate: Inj. Volume: 2 µl Temp.: 8 ºC MS Detection: Mass spec: Sample: ml/min positive-ion mode Q Exactive Plus Oxidized trastuzumab, reduced by DTT and digested by IdeS (1 mg/ml) Data collected using 28K resolution shows isotopically resolved oxidized scfc and non-oxidized scfc at +16 charge state, see below. 2 Relative Abundance Oxidized scfc scfc

21 Peptide Mapping Reversed-phase liquid chromatography of peptides is used in the biopharmaceutical industry to provide information on the nature and quality of protein therapeutics. Reversed-phase chromatography in combination with UV detection is very common in stability studies, process control, quality control, and other cases where all the important attributes of the peptide sequence are extrapolated directly from the chromatogram. In this case the assignment of a peptide to a peak is based on retention time comparison between the investigated sample and the reference one, provided that the identity of the peaks in the reference chromatogram has been determined by mass spectrometry beforehand. Since peak assignment is solely based on retention time, the highest run-to-run retention time precision is required in order to avoid incorrect peptide identification. This is complicated by the employment of in-solution digestion protocols which are time consuming (often taking in excess of 24 hours to complete) and highly irreproducible. In-solution digestion is multifaceted and laborious, with a high potential for chemically induced PTMs and autolysis, all of which can result in variation in the chromatographic profile. The Thermo Scientific SMART Digest Kits, which are based on an immobilized trypsin design, help remove these issues by providing a simple to implement process. This delivers highly reproducible digestions quickly and with increased sensitivity compared to in-solution digests. SMART Digest Add protein sample to SMART Digest tube Incubate and shake SMART Digest tube Thermo Scientific SOLAµ SPE or centrifuge/filter (optional) Analyze your sample SMART Digest vs conventional in-solution digest protocol In-solution digest <1hr 21 24hr LC-MS Analysis SMART Digest LC-MS Analysis Sample preparation Protein assay Digestion SPE + dry/reconstitute Spin down 21

22 This is complimented by the Vanquish UHPLC system featuring a binary pump with extremely low pulsation ripple, which allows highly stable flow delivery and highly precise gradient formation. The Vanquish UHPLC system is capable of providing unmatched retention time precision for gradient separations. The Acclaim RSLC 12, C18, 2.2 µm Analytical column ( mm) provides the high resolution separation required by the method. mau Column: Acclaim RSLC 12, C µm Format: Mobile Phase A: mm.5% trifluoroacetic acid in water Mobile Phase B:.4% trifluoroacetic acid in 8/2 acetonitrile/water (v/v) Gradient: Flow Rate: Inj. Volume: 5 µl Temp.: 8 ºC Detection: Sample: 4% B to 5% B in 3 minutes.4 ml/min UV (214 nm) mab tryptic digest min Average RT = RT RSD(%) =

23 Glycan Analysis Glycosylation is one of the most common post translational protein modifications (PTMs), that impacts therapeutic protein development. Most of the protein drug candidates in preclinical and clinical development, such as recombinant proteins and monoclonal antibodies (MAbs), are glycosylated. Their biological activites are often dependent on the structure and types of glycans attached to these proteins. Due to processing after en-bloc oligosaccharide transfer to the antibody, their structures can be extremely heterogeneous. Elucidation of the role(s) of antibody glycan structures is necessary for control of development and manufacturing processes for clinically important antibodies and related pharmaceuticals. Because charge, size and isomer variants may be present, structural characterization of glycan charge, size and isomers (linkage and branching) is essential for bio-therapeutic and bio-pharmaceutical projects. In order to meet the challenges of glycan analysis, we offer three different column chemistries with different selectivity. GlycanPac AXR-1 GlycanPac AXH-1 Accucore 15-Amide-HILIC Column Chemistry Alkyl chain with tertiary amine Polar groups with amine Polyamide Retention mechanism WAX/RP mixed-mode WAX/HILIC mixed-mode HILIC Silica substrate High-purity totally porous spherical silica (1.9 and 3. µm) High-purity totally porous spherical silica (1.9 and 3. µm) High-purity superficially porous spherical silica (2.6 µm) Feature Ultra-high resolution (size, charge and isomerism based separation) High-resolution with added structural information (size and charge based separation) High-resolution (size-based separation) Applications Charged glycan species (native or labeled) Neutral or charged glycans (native or labeled) Neutral glycans with labeling HILIC columns commonly used for glycan analysis are based on amide, amine, or zwitterionic packing materials. These columns separate glycans mainly by hydrogen bonding, resulting in separations based on size and composition. Accucore 15-Amide-HILIC HPLC phase is designed for the separation of hydrophilic, neutral glycans. Here is an example of human IgG glycans analyzed on an Accucore 15-Amide-HILIC HPLC columns. Counts Column: Format: Mobile Phase A: Accucore 15-Amide-HILIC, 2.6 μm mm Acetonitrile Mobile Phase B: 5 mm ammonium formate ph 4.4 (prepared from LS-N-BUFFX4, Ludger Ltd) Gradient: Time (min) %A Flow Rate: Inj. Volume: ml/min Temp.: 6 ºC Backpressure: 5 μl in water, 5 μl loop 3 bar Injection Wash Solvent: Acetonitrile/water (78:22 v/v) Excitation Wavelength: 33 nm Emission Wavelength: 42 nm 23

24 GlycanPac AXH-1 column combines both weak anion exchange (WAX) and HILIC retention mechanisms for optimal selectivity and high resolving power. The WAX functionality provides retention and selectivity for negatively charged glycans, while the HILIC mode facilitates the separation of glycans of the same charge according to their polarity and size. GlycanPac AXH-1 is designed for neutral and charged glycans analysis, in their native or labeled form. Neutral and acidic 2AB labeled N-glycan from bovine fetuin are separated using a GlycanPac AXH-1 (1.9 μm, mm) column. In total, 35 glycan peaks are resolved and detected. Intensity (counts) 12E7 1E7 8E7 6E7 4E7 2E7 Trisialylated Disialylated Tetrasialylated Neutral Monosialylated Pentasialylated Column: GlycanPac AXH-1, 1.9 µm Format: mm Mobile Phase A: Acetonitrile Mobile Phase B: D.I. water Mobile Phase C: Ammonium formate (1 mm, ph4.4) Gradient: Time (min) A% B% C% Curve Flow Rate:.4 ml/min Inj. Volume: 1 pmoles Temp.: 3 oc Detection: Fluorescence at 32/42 nm Sample: 2AB labeled N-glycan from bovine fetuin Retention Time (min) The GlycanPac AXR-1 column is based on novel mixed-mode column chemistry, combining the retention mechanisms of both WAX and reversed phase (RP) properties for optimal selectivity and resolution. The WAX functionality provides retention and selectivity for negatively charged glycans, while the reversed phase mode facilitates the separation of glycans of the same charge according to their isomeric structure, and size. As a result the GlycanPac AXR-1 column provides the highest resolution of charged 2AB-labeled N-linked glycans. 2AB-labeled N-linked glycans from bovine fetuin are separated using a GlycanPac AXR-1 (1.9 μm; mm) column. In total, 59 glycan peaks are resolved and detected. 5E7 Trisialylated Column: GlycanPac AXR-1, 1.9 µm Format: mm Mobile Phase A: Acetonitrile 4E7 Mobile Phase B: Mobile Phase C: D.I. water Ammonium formate (1 mm, ph4.4) Gradient: Time (min) A% B% C% Curve 3E Intensity (counts) 2E7 1E7 Neutral Monosialylated Disialylated Tetrasialylated Pentasialylated Flow Rate: Inj. Volume: Temp.: Detection: Sample: ml/min 1 pmoles 3 oc Fluorescence at 32/42 nm 2AB labeled N-glycan from bovine fetuin Retention Time (min) 24

25 Application Notes Visit the AppsLab Library of Analytical Applications New library of application expertise at your fingertips. Search, filter, and download complete applications and one-click workflows. thermoscientific.com/appslab Column Application Note Literature Code MAbPac Protein A A Novel Affinity Protein A Column for Monoclonal Antibody (MAb) Titer Analysis AN2813 MAbPac SEC-1 Analysis of monoclonal antibodies and their fragments by Size Exclusion Chromatography coupled with an Orbitrap Mass Spectrometer AN294 MAbPac SCX-1 High throughput, high resolution monoclonal antibody analysis with small particle size HPLC columns AN218 CX-1 ph Gradient Buffer MAbPac RP MAbPac HIC-1 MAbPac HIC-2 MAbPac HIC-butyl GlycanPac AXH-1 GlycanPac AXR-1 A Novel ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (mab) Charge Variant Analysis Separation of Intact Monoclonal Antibody Sialylation Isoforms by ph Gradient Ion-Exchange Chromatography High Resolution Charge Variant Analysis for Top-Selling Monoclonal Antibody Therapeutics Using Linear ph Gradient Separation Platform Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants Fast Analysis of Therapeutic Monoclonal Antibody Fragments Using a Supermacroporous, Reversed-Phase Chromatography Column High Resolution Separation of a Fusion Protein on MAbPac HIC-1 Column HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates High Resolution Separation of mab Fragments on MAbPac HIC-2 Column High Resolution Separation of Monoclonal Antibody (mab) Oxidation Variants on the MAbPac HIC-2 Column High Resolution Separation of Cysteine-Conjugated Antibody Drug Mimics using Hydrophobic Interaction Chromatography Separation of 2AB Labeled N-Glycans from Bovine Fetuin on a Novel Mixed-Mode Stationary Phase Structural Analysis of Native N-Glycans Released from Proteins Using a Novel Mixed-Mode Column and a Hybrid Quadrupole-Orbitrap Mass Spectrometer Separation of 2AB-Labeled N-Linked Glycans from Bovine Fetuin on a Novel Ultra High Resolution Mixed-Mode Column Separation of 2AA-Labeled N-Linked Glycans from Human IgG on a HighResolution Mixed-Mode Column Separation of 2AA-Labeled N-Linked Glycans from Glycoproteins on a High Resolution Mixed-Mode Column AN2784 AN2946 AN7162 AN2192 TN16 AN212 AN7125 AN2126 AN2147 AN2169 AN2179 AN2754 AN2827 AN298 AN299 AN291 Accucore 15-Amide-HILIC Analysis of Human IgG Glycans on a Solid Core Amide HILIC Stationary Phase AN273 Selected Publications Column ProPac WCX-1 ProPac HIC-1 Title Vlasak J. and Ionescu R. Heterogeneity of Monoclonal Antibodies Revealed by Charge-Sensitive Methods. Current Pharmaceutical Biotechnology 28; 9: Haverick M., Mengisen S., Shameem M., and Ambrogelly A. Separation of mabs molecular variants by analytical hydrophobic interaction chromatography HPLC: Overview and applications. mabs 214; 6:

26 Ordering Information Affinity Columns MAbPAC Protein A Particle Size (μm) Format Length (mm) 4. mm ID 12 HPLC Column Size Exclusion Columns MAbPac SEC-1 Particle Size (μm) Format Length (mm) 2.1 mm ID 4. mm ID 7.8 mm ID 5 HPLC Column Ion Exchange Columns MAbPac SCX-1 Particle Size (μm) Format Length (mm) 2.1 mm ID 4. mm ID 4.6 mm ID 9. mm ID 3 HPLC Column HPLC Column HPLC Column HPLC Column Lot Select 3 column (1 lot of Resin) HPLC Column Lot Select 3 column (3 lots of Resin) ProPac WCX-1 Particle Size (μm) Format Length (mm) 2. mm ID 4. mm ID 9. mm ID 22. mm ID 1 Guard Column HPLC Column ProPac SCX-1 Particle Size (μm) Format Length (mm) 2. mm ID 4. mm ID 9. mm ID 22. mm ID 1 Guard Column HPLC Column

27 ProPac SCX-2 Particle Size (μm) Format Length (mm) 4. mm ID 1 Guard Column HPLC Column ProPac WAX-1 Particle Size (μm) Format Length (mm) 2. mm ID 4. mm ID 9. mm ID 22. mm ID 1 Guard Column HPLC Column ProPac SAX-1 Particle Size (μm) Format Length (mm) 2. mm ID 4. mm ID 9. mm ID 22. mm ID 1 Guard Column HPLC Column Gradient Buffers Description MAbPac SCX-1 Column Size Buffer Bottle Size 125 ml Buffer Bottle Size 25 ml CX-1 ph Gradient Buffer A (ph 5.6) CX-1 ph Gradient Buffer B (ph 1.2) CX-1 ph Gradient Buffer Kit: Includes both Buffer A & Buffer B CX-1 ph Gradient Starter Kit: Includes both Buffer A & Buffer B 1 μm, MAbPac SCX mm column CX-1 ph Gradient High Throughput Kit; Includes both Buffer A 5 μm, & Buffer B + MAbPac SCX mm column CX-1 ph Gradient High Resolution Kit: Includes both Buffer A 5 μm, & Buffer B + MAbPac SCX mm column Hydrophobic Interaction Columns MAbPac HIC Family Description Particle Size (μm) Format Length (mm) 4.6 mm ID MAbPac HIC-1 5 HPLC Column Guard Cartridges (2/pk)* MAbPac HIC-2 5 HPLC Column Guard Cartridges (2/pk)* MAbPac HIC-Butyl 5 HPLC Column Guard Cartridges (2/pk)* *Guard Cartridge Holder (P/N 6958) ProPac HIC-1 Particle Size (μm) Format Length (mm) 2.1 mm ID 4.6 mm ID 7.8 mm ID 5 HPLC Column

28 Reversed-Phase Protein Columns MAbPac RP Particle Size (μm) Format Length (mm) 2.1 mm ID 3. mm ID 4 HPLC Column Guard Cartridges (2/pk)* *Guard Cartridge Holder (P/N 6958) ProSwift RP Packing Format Functional Group Length (mm) 1. mm ID 4.6 mm ID Monolith HPLC Column RP-1S RP-2H RP-3U RP-4H RP-1R Reversed-Phase Peptide Columns Acclaim RSLC 12 C18, Acclaim RSLC PolarAdvantage II (PA2) Particle Size (μm) Format Length (mm) ID (mm) 12 C18 Polar Advantage II 2.2 RSLC Column Acclaim 3 C18 Particle Size (μm) Format Length (mm) 2.1 mm ID 3. mm ID 4.6 mm ID 3 HPLC Column Guard Cartridges (2/pk)* *Guard Cartridge Holder (P/N 6958) 28

29 Accucore 15-C18 Columns Particle Size (μm) Format Length (mm) 2.1 mm ID 3. mm ID 4.6 mm ID.75 mm ID 2.6 HPLC Column Guard Cartridges (2/pk)* *Guard Cartridge Holder (P/N 852-) SMART Digest Kits Description Part Number SMART Digest Kit (Includes resin, buffer, and collection plate) SMART Digest Kit with Thermo Scientific SOLAµ HRP SPE plate (Includes resin, buffer, collection plate, and SOLAµ SPE plate) SMART Digest Kit with 96 well filter plate (Includes resin, buffer, collection plate, and filter plate) Glycan Analysis Columns GlycanPac AXH-1 Columns Particle Size (μm) Format Length (mm) 2.1 mm ID 3. mm ID 4.6 mm ID 1.9 HPLC Column Guard Cartridges (2/pk)* *Guard Cartridge Holder (P/N 6958) GlycanPac AXR-1 Columns Particle Size (μm) Format Length (mm) 2.1 mm ID 3. mm ID 4.6 mm ID 1.9 HPLC Column Guard Cartridges (2/pk)* *Guard Cartridge Holder (P/N 6958) Accucore 15-Amide-HILIC Columns Particle Size (μm) Format Length (mm) 2.1 mm ID 3. mm ID 4.6 mm ID 2.6 HPLC Column Guard Cartridges (2/pk)* *Guard Cartridge Holder (P/N 852-) 29

30 for biopharmaceutical markets Your sample is precious and you cannot afford failures. We have a comprehensive range of Thermo Scientific product delivering clean and consistent extractions using innovative sample preparation technologies for your analytical needs. MSIA D.A.R.T.s Versette Automated Liquid Handler Reproducible, automated affinity purification SMART Digest Kits Facilitating perfect digestion SOLAμ SPE Plates Increased sensitivity Sample Preparation Data Management Watson LIMS and Data Manager Powerful data processing, reporting and SDMS Chromeleon Chromatography Data System Streamlining laboratory workflow 3

31 WebSeal Sample integrity and cleanliness Varioskan LUX Multimode Microplate Reader Orbitor RS Microplate Mover High-throughput lab automation Sample Handling Separation and Detection BioLC/UHPLC Columns Separation technologies for every workflow Orbitrap Fusion Lumos Tribrid Mass Spectrometer The new standard in characterization and quantitation Vanquish UHPLC Systems Built for every biopharma workflow 31

32 216 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR21425-EN 616S

mabs and ADCs analysis by RP

mabs and ADCs analysis by RP mabs and ADCs analysis by RP Shanhua Lin, Ph.D. The world leader in serving science Protein and mab Separation by HPLC Size difference? YES Size Exclusion Chromatography (SEC) MAbPac SEC-1 NO NO Charge

More information

Thermo Scientific BioLC Columns. Monoclonal antibody. characterization

Thermo Scientific BioLC Columns. Monoclonal antibody. characterization Thermo Scientific BioLC Columns Monoclonal antibody characterization Innovative technologies and workflows for increasing productivity and throughput Table of Contents Characterization of Monoclonal Antibodies

More information

Development of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns

Development of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns Development of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns Anne Blackwell Bio Columns Product Support Scientist Suresh Babu Senior Application

More information

SMART Digest Kit User Manual. Version 2

SMART Digest Kit User Manual. Version 2 SMART Digest Kit User Manual Version 2 XX21543 Revision A August 2016 SMART Digest Kit Delivering simple, fast and reproducible digestion of proteins Thermo Scientific SMART Digest kits are designed for

More information

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates Julia Baek, Shanhua Lin, Xiaodong Liu, Thermo Fisher Scientific, Sunnyvale, CA Application Note 2126 Key Words Size exclusion

More information

Thermo Scientific LC Columns for Biomolecules

Thermo Scientific LC Columns for Biomolecules LC Columns and Accessories Thermo Scientific Chromatography Columns and Consumables 2014-2015 Thermo Scientific LC Columns for Biomolecules The diversity of biological samples in terms of compound structure

More information

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC Analysis of Intact and Fragmented mabs and ADC Application Note Biotherapeutics and Biologics Author Suresh Babu C.V. Agilent

More information

Thermo Scientific Technical Resources Document 1.5. LC Columns and Accessories. for Biomolecules

Thermo Scientific Technical Resources Document 1.5. LC Columns and Accessories. for Biomolecules 1.5 1.0 0.5 Thermo Scientific Technical Resources Document LC Columns and Accessories for Biomolecules Section Contents Introduction...4-002 Bio Columns Selection Guide...4-003 HPLC s for Biomolecules...4-004

More information

MAbPac SCX-10 Columns

MAbPac SCX-10 Columns User Manual MAbPac SCX-10 Columns 065393 Revision 09 October 2015 For Research Use Only. Not for use in diagnostic procedures. Product Manual for MAbPac SCX-10, 10µm Analytical Column (10μm, 9 x 250 mm,

More information

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS Agilent AdvanceBio Columns ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS with Agilent ZORBAX RRHD 3Å 1.8 µm columns ns Rapid resolution high definition columns for UHPLC protein and peptide separations

More information

Advanced QA/QC characterization MS in QC : Multi Attribute Method

Advanced QA/QC characterization MS in QC : Multi Attribute Method Advanced QA/QC characterization MS in QC : Multi Attribute Method Global BioPharma Summit The world leader in serving science A Complex Problem: Drug Safety and Quality Safety Is the product safe to use?

More information

2012 Waters Corporation 1

2012 Waters Corporation 1 UPLC User meeeting April 2012 Principles and Practices for SEC, IEX for Intact Protein Analysis by UPLC anders_feldthus@waters.com 2012 Waters Corporation 1 Agenda Ion-Exchange Chromatography Theory and

More information

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping. Thermo Scientific Peptide Mapping Workflows Upgrade Your Maps Fast, confident and more reliable peptide mapping. Smarter Navigation... Peptide mapping is a core analytic in biotherapeutic development.

More information

Analysis of biomolecules by SEC and Ion-Exchange UPLC

Analysis of biomolecules by SEC and Ion-Exchange UPLC Analysis of biomolecules by SEC and Ion-Exchange UPLC Anders Feldthus, Waters Nordic 2011 Waters Corporation 1 Waters Commitment To develop, commercialize and market columns that when used on Waters ACQUITY

More information

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis Shanhua Lin, Julia Baek, and Chris Pohl Thermo Fisher Scientific, Sunnyvale, CA, USA Overview

More information

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles Application Note Biotherapeutics and Biosimilars Authors James Martosella, Alex

More information

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility Technical Overview Introduction Agilent AdvanceBio SEC columns are a new family of size exclusion chromatography (SEC) columns

More information

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis APPLICATION NOTE 72362 Lifetime stability of size exclusion chromatography columns for protein aggregate analysis Authors Amy Farrell 1, Craig Jakes 1, Alexander Ley 2, Mauro De Pra 2, Frank Steiner 2,

More information

High-Throughput Peptide Mapping with the Vanquish UHPLC System and the Q Exactive HF Mass Spectrometer

High-Throughput Peptide Mapping with the Vanquish UHPLC System and the Q Exactive HF Mass Spectrometer High-Throughput Peptide Mapping with the Vanquish UHPLC System and the Q Exactive HF Mass Spectrometer Martin Samonig 1, Kai Scheffler 2, Remco Swart 1, and Jonathan Josephs 3 1 Thermo Fisher Scientific,

More information

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus Robert Birdsall, Thomas Wheat, and Weibin Chen Waters Corporation,

More information

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development Thermo Scientific Solutions for Intact-Protein Analysis Better, Faster Decisions for Biotherapeutic Development Quickly and Accurately Assess Product Quality and Safety Therapeutic proteins and monoclonal

More information

Monoclonal Antibody Characterization Achieving Higher Throughput and Productivity

Monoclonal Antibody Characterization Achieving Higher Throughput and Productivity Monoclonal Antibody Characterization Achieving Higher Throughput and Productivity Dionex Solutions to Accelerate Monoclonal Antibody R&D and Characterization The throughput and productivity challenge Increasing

More information

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography Characterize Fab and Fc Fragments by Cation-Exchange Chromatography Application Note Biologics and Biosimilars Authors Isabel Vandenheede, Emmie Dumont, Pat Sandra, and Koen Sandra Research Institute for

More information

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF Application Note Author David L. Wong Agilent Technologies, Inc. Santa Clara, CA, USA Introduction Monoclonal

More information

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF Application Note Authors Xianming Liu, Wei Zhang, Yi Du, Sheng Yin, Hong Que, and Weichang Zhou WuXi AppTec iopharmaceuticals

More information

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb µm Column Application Note BioPharma Authors Xiaomi Xu and Phu T Duong Agilent Technologies, Inc. Abstract Nearly all proteins undergo

More information

Zwitterion Chromatography ZIC

Zwitterion Chromatography ZIC Zwitterion Chromatography ZIC A novel technique, with unique selectivity, suitable for preparative scale separations? PhD Einar Pontén What is Zwitterion Chromatography? Our definition: Liquid chromatography

More information

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website:  Published in November 2013 5-100 Innovation Way Newark, DE 19711, USA Tel:302-3661101 Fax:302-3661151 Website: www.sepax-tech.com Published in November 2013 P/N SECKIT-7830 These Phases are developed based on innovative surface

More information

mab Glycopeptide Profiling with V-Tag Adding reliable glycoprofiling to your peptide mapping workflow with ease and simplicity

mab Glycopeptide Profiling with V-Tag Adding reliable glycoprofiling to your peptide mapping workflow with ease and simplicity mab Glycopeptide Profiling with V-Tag Adding reliable glycoprofiling to your peptide mapping workflow with ease and simplicity Who is the V-Tag Glycoprofiling Technology for? V = Velocity The Ludger V-Tag

More information

A universal chromatography method for aggregate analysis of monoclonal antibodies

A universal chromatography method for aggregate analysis of monoclonal antibodies APPLICATION NOTE A universal chromatography method for aggregate analysis of monoclonal antibodies No. 2161 Amy Farrell 1, Jonathan Bones 1, and Ken Cook 2 1 NIBRT, Dublin, Ireland; 2 Thermo Fisher Scientific,

More information

Analysis and Purification of Polypeptides by Reversed-Phase HPLC

Analysis and Purification of Polypeptides by Reversed-Phase HPLC Analysis and Purification of Polypeptides by Reversed-Phase HPLC Reversed-phase HPLC is a valuable tool for the analysis and purification of proteins and peptides. It is effective in separating peptide

More information

Thermo Scientific LC Columns and Accessories More capabilities New possibilities

Thermo Scientific LC Columns and Accessories More capabilities New possibilities Thermo Scientific LC Columns and Accessories More capabilities New possibilities Dionex products strengthen our LC column offering creating new and exciting possibilities for scientific analysis Trusted

More information

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1 Routine Characterization of mabs and Other Proteins Patrick Boyce Biopharmaceutical Marketing Manager Europe and India 2011 Waters Corporation 1 Agenda Why? What scientific challenges? Technology Example

More information

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column Disulfide Linkage Analysis of IgG1 using an Agilent 126 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column Application Note Biotherapeutics & Biosimilars Author M. Sundaram

More information

CQA Assessment by Peptide Mapping Using LC/MS with an AdvanceBio Peptide Plus Column

CQA Assessment by Peptide Mapping Using LC/MS with an AdvanceBio Peptide Plus Column CQA Assessment by Peptide Mapping Using LC/MS with an AdvanceBio Peptide Plus Column Anne Blackwell, Ph.D. BioColumns Product Support Scientist June 7, 27 ASMS Analytical groups are tasked with method

More information

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS Application Note Biopharmaceuticals and Biosimilars Authors Emmie Dumont, Isabel Vandenheede, Pat Sandra, Koen Sandra Research

More information

Application Note. Kwasi Antwi, Amanda Ribar, Urban A. Kiernan, and Eric E. Niederkofler Thermo Fisher Scientific, Tempe, Arizona

Application Note. Kwasi Antwi, Amanda Ribar, Urban A. Kiernan, and Eric E. Niederkofler Thermo Fisher Scientific, Tempe, Arizona Analysis of an Antibody Drug Conjugate using MSIA D.A.R.T. S. Technology, an Integral Part of Ligand Binding Mass Spectrometric Immunoassay (LB-MSIA) Workflow Application Note Kwasi Antwi, Amanda Ribar,

More information

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover columns ProSwift Reversed-Phase Monolith Columns for Protein Analysis ProSwift reversed-phase columns use a unique monolith technology for fast, high-resolution HPLC and LC/MS separations of proteins.

More information

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns Agilent AdvanceBio SEC 3 Å, 2.7 µm columns Application note Bio-Pharmaceutical Author

More information

Utilizing novel technology for the analysis of therapeutic antibodies and host cell protein contamination

Utilizing novel technology for the analysis of therapeutic antibodies and host cell protein contamination Utilizing novel technology for the analysis of therapeutic antibodies and host cell protein contamination Kelli Jonakin, Ph.D. Senior Field Application Scientist, Seattle, WA Eric Johansen, Ph.D. Senior

More information

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns Hongwei Xie, Martin Gilar, and Jeff Mazzeo Waters Corporation, Milford, MA U.S. APPLICATION BENEFITS The ACQUITY UPLC

More information

Method Development Considerations for Reversed-Phase Protein Separations

Method Development Considerations for Reversed-Phase Protein Separations Method Development Considerations for Reversed-Phase Protein Separations Hillary B. Hewitson, Thomas E. Wheat, Paula Hong, Kenneth J. Fountain APPLICATION BENEFITS n The BEH00 C 4 chemistry is available

More information

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider Combining small-scale purification and analysis of monoclonal antibodies on one instrument Protein purification with high-volume injection using the Agilent 126 Infinity Bio-inert Quaternary LC System

More information

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System Application Note Biologics & Biosimilars Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction Chromatography Agilent 126 Infinity II Bio-Inert System 7 6 5 4 5. 7.5

More information

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA LECTURE-06 PROTEIN PURIFICATION AND PEPTIDE ISOLATION USING CHROMATOGRAPHY TRANSCRIPT Welcome to the proteomics course. Today, we will talk about protein purification and peptide isolation using chromatography

More information

Peptide Mapping: A Quality by Design (QbD) Approach

Peptide Mapping: A Quality by Design (QbD) Approach Peptide Mapping: A Quality by Design (QbD) Approach Application Note Bio-Pharmaceutical Authors Sreelakshmy Menon and Suresh babu C.V. Agilent Technologies, Inc. Richard Verseput S-Matrix Corporation Abstract

More information

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides High-pH-stable, superficially porous particle columns for LC/UV and LC/MS Application Note Biologics and Biosimilars Authors

More information

Tony Mire-Sluis Vice President, Corporate, Product and Device Quality Amgen Inc

Tony Mire-Sluis Vice President, Corporate, Product and Device Quality Amgen Inc The Regulatory Implications of the ever increasing power of Mass Spectrometry and its role in the Analysis of Biotechnology Products Where do we draw the line? Tony Mire-Sluis Vice President, Corporate,

More information

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany D-LC/MS Characterization of Charge Variants Using Ion Exchange and Reversed-Phase Chromatography Multiple Heart-Cutting D-LC Analysis of Innovator versus Biosimilar Monoclonal Antibodies Application Note

More information

Characterization of Glycosylation in the Fc Region of Therapeutic Recombinant Monoclonal Antibody

Characterization of Glycosylation in the Fc Region of Therapeutic Recombinant Monoclonal Antibody Characterization of Glycosylation in the Fc Region of Therapeutic Recombinant Monoclonal Antibody Application Note BioPharma Authors James Martosella, Phu Duong, and Alex Zhu Agilent Technologies, Inc.

More information

PolyCAT A For Cation-Exchange

PolyCAT A For Cation-Exchange PolyCAT A For Cation-Exchange The PolyCAT A is made though a unique process for attaching Poly(aspartic acid) covalently to silica. Proteins elute from this polypeptide coating in sharp peaks with little

More information

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study MagSi Beads Magnetic Silica Beads for Life Science and Biotechnology study MagnaMedics Diagnostics B.V. / Rev. 9.2 / 2012 Wide range of products for numerous applications MagnaMedics separation solutions

More information

Antibody Analysis by ESI-TOF LC/MS

Antibody Analysis by ESI-TOF LC/MS Application Note PROTEOMICS METABOLOMICS GENOMICS INFORMATICS GLYILEVALCYSGLUGLNALASERLEUASPARG CYSVALLYSPROLYSPHETYRTHRLEUHISLYS Antibody Analysis by ESI-TOF LC/MS Authors Lorenzo Chen, Merck & Company,

More information

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column mab Titer Analysis with the Agilent Bio-Monolith Protein A Column Application Note Biopharmaceuticals and Biosimilars Authors Emmie Dumont, Isabel Vandenheede, Pat Sandra, and Koen Sandra Research Institute

More information

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics Catalin Doneanu,, Ph.D. Biopharmaceutical Sciences, Waters September 16, 2009 Mass Spec 2009 2009 Waters Corporation Host Cell Proteins

More information

Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns

Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns Michael McGinley, Jeff Layne, and Vita Knudson Phenomenex, Inc., 411 Madrid Ave.,Torrance,

More information

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI with the Biopharmaceutical Platform Solution with UNIFI Vera B. Ivleva, Ying Qing Yu, Scott Berger, and Weibin Chen Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S The ability to

More information

Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants

Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal ntibody Charge Variants Ken Cook, Frank Steiner, Mauro De Pra Thermo Fisher Scientific, Hemel Hempstead,

More information

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study Application note Biotherapeutics and Biologics Authors Suresh Babu C.V., Anne

More information

Monosaccharide and Sialic Acid Determinations in Biosimilars Using HPAE-PAD

Monosaccharide and Sialic Acid Determinations in Biosimilars Using HPAE-PAD Monosaccharide and Sialic Acid Determinations in Biosimilars Using HPAE-PAD A large number of innovator biotherapeutics are currently losing patent protection, resulting in an increased interest to develop

More information

Protein-Pak Hi Res HIC Column and HIC Protein Standard

Protein-Pak Hi Res HIC Column and HIC Protein Standard Protein-Pak Hi Res HIC Column and HIC Protein Standard CONTENTS I. INTRODUCTION II. a. Mobile Phase b. Flow Direction CONNECTING COLUMN TO LC SYSTEM I. INTRODUCTION This offering contains non-porous, polymethacrylate-based

More information

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS Application Note BioPharma Authors Alex Zhu, James Martosella, and Phu T Duong Agilent Technologies, Inc Introduction Peptide

More information

Introduction to Protein Purification

Introduction to Protein Purification Introduction to Protein Purification 1 Day 1) Introduction to Protein Purification. Input for Purification Protocol Development - Guidelines for Protein Purification Day 2) Sample Preparation before Chromatography

More information

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column Application Note Bio-Pharmaceutical Authors M. Sundaram Palaniswamy and Andrew Coffey Agilent Technologies,

More information

Rapidly Characterize Antibody- Drug Conjugates and Derive Drug-to-Antibody Ratios Using LC/MS

Rapidly Characterize Antibody- Drug Conjugates and Derive Drug-to-Antibody Ratios Using LC/MS Rapidly Characterize Antibody- Drug Conjugates and Derive Drug-to-Antibody Ratios Using LC/MS Ning Tang, Ph.D. Agilent Technologies Santa Clara, California, USA Heterogeneity in ADCs Complexity T-DM1 (Genentech)

More information

Mass Spectrometry for Characterization of Monoclonal Antibodies: Regulatory Considerations

Mass Spectrometry for Characterization of Monoclonal Antibodies: Regulatory Considerations Mass Spectrometry for Characterization of Monoclonal Antibodies: Regulatory Considerations Jun Park, Ph.D. Division of Monoclonal Antibodies Office of Biotechnology Products OPS/CDER Food and Drug Administration

More information

Trastuzumab Glycan Batch-to-Batch Profiling using a UPLC/FLR/Mass Spectrometry Platform

Trastuzumab Glycan Batch-to-Batch Profiling using a UPLC/FLR/Mass Spectrometry Platform Trastuzumab Glycan Batch-to-Batch Profiling using a UPLC/FLR/Mass Spectrometry Platform Ying Qing Yu, Joomi Ahn, and Martin Gilar Waters Corporation, Milford, MA, U.S. APPLICATION BENEFITS Used together,

More information

Sepax Technologies, Inc.

Sepax Technologies, Inc. Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, bio-surfaces and proteomics. Sepax product portfolio includes 1)

More information

SMART Digest compared to classic in-solution digestion of rituximab for in-depth peptide mapping characterization

SMART Digest compared to classic in-solution digestion of rituximab for in-depth peptide mapping characterization APPLICATION NOTE Digest compared to classic in-solution digestion of rituximab for in-depth peptide mapping characterization No. 1159 Authors: Martin Samonig 1, Alexander Schwahn 2, Ken Cook 3, Mike Oliver

More information

Kinetics Review. Tonight at 7 PM Phys 204 We will do two problems on the board (additional ones than in the problem sets)

Kinetics Review. Tonight at 7 PM Phys 204 We will do two problems on the board (additional ones than in the problem sets) Quiz 1 Kinetics Review Tonight at 7 PM Phys 204 We will do two problems on the board (additional ones than in the problem sets) I will post the problems with solutions on Toolkit for those that can t make

More information

Size Exclusion Chromatography/ Mass Spectrometry Analysis of Antibody Drug Conjugates Using the Agilent 1260 Infinity II Bio-Inert LC

Size Exclusion Chromatography/ Mass Spectrometry Analysis of Antibody Drug Conjugates Using the Agilent 1260 Infinity II Bio-Inert LC Size Exclusion Chromatography/ Mass Spectrometry Analysis of Antibody Drug Conjugates Using the Agilent 126 Infinity II Bio-Inert LC Application Note Biologics & Biosimilars Author Sonja Schneider Agilent

More information

Reversed Phase Solutions for the Analysis of Proteins, Peptides, and Oligonucleotides

Reversed Phase Solutions for the Analysis of Proteins, Peptides, and Oligonucleotides Reversed Phase Solutions for the Analysis of Proteins, Peptides, and Oligonucleotides The line, which includes and Proteo, offers various reversed phase solutions for biochromatography. With these two

More information

Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs

Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs Technical Overview Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs Authors Stephen Madden, Crystal Cody, and Jungkap Park Agilent Technologies, Inc. Santa Clara, California,

More information

ProSEC 300S. Protein Characterization columns

ProSEC 300S. Protein Characterization columns ProSEC 300S Protein Characterization columns Agilent s ProSEC 300S is a silica-based material specifically designed for the analysis of proteins by aqueous size exclusion chromatography. With a proprietary

More information

Antibody-drug Conjugates: Characterization and Control Strategies of Lysine-linked Products

Antibody-drug Conjugates: Characterization and Control Strategies of Lysine-linked Products Antibody-drug Conjugates: Characterization and Control Strategies of Lysine-linked Products Fred Jacobson Protein Analytical Chemistry Genentech, Inc. CASSS CMC Strategy Forum Japan 2013 December 9-10,

More information

An effective platform for purification of IgM monoclonal antibodies using Hydroxyapatite

An effective platform for purification of IgM monoclonal antibodies using Hydroxyapatite An effective platform for purification of IgM monoclonal antibodies using Hydroxyapatite Frank Hensel, Patrys, GmbH Pete Gagnon, Validated Biosystems 5th International Conference on Hydroxyapatite and

More information

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution Rapidly Identify Major Catabolites with the SCIEX X500R QTOF System and MetabolitePilot TM 2.0 Software Ian Moore and Jinal Patel

More information

Rhinophase -AB, Zirconia-based Monoclonal Antibody Purification System

Rhinophase -AB, Zirconia-based Monoclonal Antibody Purification System Rhinophase -AB, Zirconia-based Monoclonal Antibody Purification System Welcome to the sixth issue of ZirChrom's electronic newsletter. This newsletter introduces a biocompatible stationary phase useful

More information

Peptide libraries: applications, design options and considerations. Laura Geuss, PhD May 5, 2015, 2:00-3:00 pm EST

Peptide libraries: applications, design options and considerations. Laura Geuss, PhD May 5, 2015, 2:00-3:00 pm EST Peptide libraries: applications, design options and considerations Laura Geuss, PhD May 5, 2015, 2:00-3:00 pm EST Overview 1 2 3 4 5 Introduction Peptide library basics Peptide library design considerations

More information

'Tips and Tricks' for Biopharmaceutical Characterization using SEC

'Tips and Tricks' for Biopharmaceutical Characterization using SEC 'Tips and Tricks' for Biopharmaceutical Characterization using SEC Waters Corporation 2012 Waters Corporation 1 Waters Commitment To develop, commercialize and market columns that, when used on Waters

More information

Capillary Electrophoresis Compendial Applications

Capillary Electrophoresis Compendial Applications Capillary Electrophoresis Compendial Applications Anita Szajek, Ph.D. Principal Scientific Liaison, Biologics & Biotechnology 14 th Symposium on the Practical Applications for the Analysis of Proteins,

More information

Accucore. Ultimate Core Performance LC Column Technology to Maximize Your Investment. Dave Jarzinski. October 2011

Accucore. Ultimate Core Performance LC Column Technology to Maximize Your Investment. Dave Jarzinski. October 2011 Accucore Ultimate Core Performance LC Column Technology to Maximize Your Investment Dave Jarzinski Thermo Fisher Scientific Account Manager Greater Boston/Cambridge & North Phone: 978-408-1576 Email: dave.jarzinski@thermofisher.com

More information

Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis

Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis Atis Chakrabarti* and Roy Eksteen + Tosoh Bioscience LLC, King of Prussia, PA 19406 *Corresponding Author. + Current address:

More information

Superdex 200 Increase columns

Superdex 200 Increase columns GE Healthcare Life Sciences Data file 29-452-69 AA Size exclusion chromatography Superdex 2 Increase columns Superdex 2 Increase prepacked columns (Fig 1) are designed for size exclusion chromatography

More information

Monoclonal Antibody Characterization on Q Exactive and Oribtrap Elite. Yi Zhang, Ph.D Senior Proteomic Marketing Specialist Oct.

Monoclonal Antibody Characterization on Q Exactive and Oribtrap Elite. Yi Zhang, Ph.D Senior Proteomic Marketing Specialist Oct. Monoclonal Antibody Characterization on Q Exactive and Oribtrap Elite Yi Zhang, Ph.D Senior Proteomic Marketing Specialist Oct. 12, 211 Outline Orbitrap Mass Spectrometer in mab Characterization Intact

More information

Technical Challenges in the Development of Biosimilars. E. Morrey Atkinson, PhD Interphex May 1, 2012

Technical Challenges in the Development of Biosimilars. E. Morrey Atkinson, PhD Interphex May 1, 2012 Technical Challenges in the Development of Biosimilars E. Morrey Atkinson, PhD Interphex May 1, 2012 FDA Guidance on Biosimilarity Guidance for Industry: Scientific Consideration in Demonstrating Biosimilarity

More information

LabChip GXII: Antibody Analysis

LabChip GXII: Antibody Analysis WHITE PAPER LabChip GXII: Antibody Analysis Antibody Analysis using microfluidic technology in high throughput Quality by Design Experiments Abstract Current initiatives in Process Analytical Technology

More information

Bio-Monolith Protein G Column - More Options for mab Titer Determination

Bio-Monolith Protein G Column - More Options for mab Titer Determination Bio-Monolith Protein G Column - More Options for mab Titer Determination Application Note Biologics and Biosimilars Author Phu T. Duong Agilent Technologies, Inc. Introduction In recent years, monoclonal

More information

phab Amine and Thiol Reactive Dyes for Antibody Internalization Studies Nidhi Nath, Ph.D. Group Leader, Protein Analysis Promega Corporation

phab Amine and Thiol Reactive Dyes for Antibody Internalization Studies Nidhi Nath, Ph.D. Group Leader, Protein Analysis Promega Corporation phab Amine and Thiol Reactive Dyes for Antibody Internalization Studies Nidhi Nath, Ph.D. Group Leader, Protein Analysis 1 Outline 1. phab Dyes 2. Protocols for conjugating phab Dyes to antibodies 3. Applications:

More information

Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins

Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins Esther Lewis, 1 Kevin Meyer, 2 Zhiqi Hao, 1 Nick Herold,

More information

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS Zhiqi Hao, 1 Yi Zhang, 1 David Horn, 1 Seema Sharma, 1 Shiaw-Lin

More information

Jürgen Fichtl, Development Characterization Pharma Technical Development, Penzberg, Germany Mass Spec 2013, September 23-26, Boston

Jürgen Fichtl, Development Characterization Pharma Technical Development, Penzberg, Germany Mass Spec 2013, September 23-26, Boston Analytical Strategies for Assessment of Disulfide Linkages in Biopharmaceuticals Jürgen Fichtl, Development Characterization Pharma Technical Development, Penzberg, Germany Mass Spec 2013, September 23-26,

More information

1. Connect the column to the chromatography system, syringe or pump.

1. Connect the column to the chromatography system, syringe or pump. BabyBio TREN INSTRUCTIONS IN 45 655 030 The ready-to-use BabyBio TREN columns are prepacked with WorkBeads 40 TREN resin and are available in two column sizes, 1 ml and 5 ml. WorkBeads 40 TREN resin for

More information

Advantages of Ion Mobility QTOF for Characterization of BioPharma Molecules

Advantages of Ion Mobility QTOF for Characterization of BioPharma Molecules Advantages of Ion Mobility QTOF for Characterization of BioPharma Molecules Add a New Dimension to your Research Capability with Agilent s New Drift Ion Mobility QTOF System David Wong, Ph.D. Sr. Application

More information

Bivalirudin Purification:

Bivalirudin Purification: Bivalirudin Purification: Sorbent Screening and Overload Experiments Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO94190412_W Abstract In this

More information

Purification: Step 1. Lecture 11 Protein and Peptide Chemistry. Cells: Break them open! Crude Extract

Purification: Step 1. Lecture 11 Protein and Peptide Chemistry. Cells: Break them open! Crude Extract Purification: Step 1 Lecture 11 Protein and Peptide Chemistry Cells: Break them open! Crude Extract Total contents of cell Margaret A. Daugherty Fall 2003 Big Problem: Crude extract is not the natural

More information

Purification: Step 1. Protein and Peptide Chemistry. Lecture 11. Big Problem: Crude extract is not the natural environment. Cells: Break them open!

Purification: Step 1. Protein and Peptide Chemistry. Lecture 11. Big Problem: Crude extract is not the natural environment. Cells: Break them open! Lecture 11 Protein and Peptide Chemistry Margaret A. Daugherty Fall 2003 Purification: Step 1 Cells: Break them open! Crude Extract Total contents of cell Big Problem: Crude extract is not the natural

More information

Product. Ni-NTA His Bind Resin. Ni-NTA His Bind Superflow. His Bind Resin. His Bind Magnetic Agarose Beads. His Bind Column. His Bind Quick Resin

Product. Ni-NTA His Bind Resin. Ni-NTA His Bind Superflow. His Bind Resin. His Bind Magnetic Agarose Beads. His Bind Column. His Bind Quick Resin Novagen offers a large variety of affinity supports and kits for the purification of recombinant proteins containing popular peptide fusion tags, including His Tag, GST Tag, S Tag and T7 Tag sequences.

More information

Two-Dimensional LC Protein Separation on Monolithic Columns in a Fully Automated Workflow

Two-Dimensional LC Protein Separation on Monolithic Columns in a Fully Automated Workflow Technical Note Two-Dimensional LC Protein Separation on Monolithic Columns in a Fully Automated Workflow Introduction The complex nature of proteomics samples requires high-resolution separation methods

More information