Every Step. Every Detail.
|
|
- Jerome Woods
- 5 years ago
- Views:
Transcription
1 3M Sterilization Products and Services Every Step. Every Detail. Every Day M Sterilization: Comprehensive Monitoring Portfolio World Class Technical Support Expert Sales Support 3M Attest Sterile U Network Education Program
2 3M Technical Support: option 2 3M Health Care Service Center: M Healthcare Helpline: M Technical and Sales Professionals: Internet Resources: Today s busy sterile processing department is challenged with meeting the increased demand for quick turnaround of processed items without compromising adherence to standards, guidelines and recommended practices. The 3M Sterilization Assurance Program can help you proceed with confidence with a comprehensive approach to all areas of monitoring and record keeping. For more than 50 years, 3M has had a reputation for innovation in sterilization products. In addition, 3M also provides technical service that helps improve the knowledge, professionalism and productivity of the sterile processing department.
3 3M Sterilization Working directly with you. 3M understands the challenges you re facing in sterilization: growing concerns about risk management and health care liability, shrinking budgets, stringent documentation requirements and the need to standardize policies and procedures for a variety of health care settings and locations. We ll work with you to meet the needs of your organization...from the high volume of large facilities to the individualized needs of outpatient surgery centers and primary care clinics. In today s health care environment, you demand speed, accuracy, credibility and efficiency in all phases of the sterilization process. 3M stands ready to put our leadership, sterilization products, services and educational tools to work for you. As a worldwide leader in sterilization assurance, 3M s comprehensive product line is backed by excellence in innovation, experience and service. Contents 1 3M Sterilization 8 Rapid Readout Biological Indicators 10 Biological Indicators 12 Bowie-Dick Test Packs 13 Class 5 Chemical Integrators 14 Chemical Integrators and Indicators 15 Chemical Indicators 19 Indicator Tapes 21 Record Keeping 24 Clean and Disinfect 25 Sterilization Equipment 29 Sterilization Packaging 30 Index 3M Sterilization 1
4 3M Attest Sterile U Education Programs 3M Attest Products Sterile U is a network of educational services and training resources, provided by 3M, dedicated to improving competency and confidence in the field of sterility assurance. 3M Attest Sterile U Online 3M Attest Sterile U Online integrates in one location all 3M Sterilization Assurance educational materials, including 30+ free CE credited in-service articles, Web meeting archives, tutorials, FAQs, and more. To register for exclusive access, go to and provide the requested information. Upon registering, you will receive an confirming your participation with a URL link to the actual website portal. Be sure to "bookmark" the URL for ongoing access. 3M Attest Sterile U Web Meetings 3M Attest Sterile U Web Meetings are free, interactive web-based programs on today's most talked-about sterilization issues. Register for these CE credited sessions at 2 3M Sterilization
5 3M Attest Sterile U Seminars 3M Attest Sterile U Seminars are conducted by 3M technical service and industry experts at health care facilities throughout the U.S. These CE credited seminars emphasize best practices in sterilization monitoring. Our schedule is posted on 3M Attest Sterile U Online or contact your 3M Sales Representative if you are interested in hosting an event. 3M Attest Sterile U Self-Study Materials 3M Attest Sterile U is proud to support ongoing Sterile Processing recertification via IAHCSMM and CBSPD through a variety of self-study CE credited education materials available on 3M Attest Sterile U Online. These free CEs are easy to administer. Simply complete the program, fill out the accompanying certificate and submit your certificate(s) to IAHCSMM or CBSPD when you recertify. If you have questions regarding any of the 3M Attest Sterile U resources, please contact the 3M Healthcare Helpline at or 3matteststerileu@mmm.com 3M Sterilization 3
6 Steps in the Sterilization Process Health care professionals worldwide have come to trust the complete line of 3M sterilization monitoring products to help them monitor all stages of the sterilization process. 3M sets today s standard for sterilization process monitoring with a comprehensive monitoring portfolio, the 3M Attest Sterile U Network education program, world class technical service support and expert sales support. 1. Clean and Disinfect The first step in the sterilization process, clean and disinfect, addresses the removal of foreign material and makes instruments ready for further processing. The presence of soil or organic material on instruments reduces disinfection or sterilization effectiveness. If the instruments are going to be high level disinfected, a check of the high level disinfectant concentration in the processor/soaking tray is required to ensure its minimum effective concentration. 2. Prep and Pack Prep and pack is next in the sterilization process. The proper selection of internal and external chemical indicators to monitor the sterilization process is done in this step. 3. In the third step of the sterilization process, instruments are exposed to the actual sterilant (steam, ethylene oxide, etc.). Routine monitoring of the sterilization process is needed to ensure effective sterilization. This is done through the use of displays and printouts from the equipment and the proper selection and the use of biological and chemical indicators. 4. In the fourth step, instruments are removed from the sterilizer/processor and quality system documentation is completed. Then, appropriate storage is required to maintain the integrity of the packaging and level of sterility of the instrument(s) prior to use. Documentation for each individual pack is recommended by AAMI, AORN and The Joint Commission to ensure that a load or pack can be identified and found in the event of a recall. This documentation is part of a total record keeping system and is an important aspect of the department quality system. 5. Issue and Use Finally, when items are requested for use, they are retrieved from storage and checked to ensure that the external chemical monitor has reached its endpoint (e.g., color change or migration) and then issued for use. Prior to use, the internal chemical monitors are checked to ensure that sterilization process conditions penetrated to the inside of the pack. 4 3M Sterilization
7 Who to turn to for standards and recommended practices for sterilization monitoring 3M Sterilization is actively involved with various industry associations in their ongoing effort to increase the science and professionalism of reprocessing instruments. We encourage you to investigate the standards they have developed to address this subject. AAMI The Association for the Advancement of Medical Instrumentation is a U.S. national standards organization devoted to medical technology. It is a nonprofit organization made up of representatives from healthcare, industry, governmental regulators, academia and consultants that work together to develop consensus performance standards and recommended practices on medical instrumentation and technology. The AAMI Sterilization Standards Committees comprise one of the largest divisions of AAMI. ANSI/AAMI ST79 Comprehensive guide to steam sterilization and sterility assurance in health care facilities is the highest selling AAMI document. In addition to standards development, AAMI also sponsors multiple educational programs. AORN The Association of perioperative Registered Nurses is a professional organization that provides OR nurses with education and standards of practice. AORN hosts educational meetings, national congress, publications and provides multiple other resources. AORN PeriOperative Standards and Recommended Practices are published annually and serve as the primary reference for OR best practice. CDC The Centers for Disease Control and Prevention is part of the U.S. Dept. of Health and Human Services and is focused on protecting public safety through the prevention and control of disease, injury and disability. CDC focuses on key aspects of infection prevention including HAIs. The Healthcare Information Control Practices Advisory Committee (HICPAC) is sponsored by the CDC and develops good practice guidelines. ISO ISO (International Organization for Standardization) is a network of the national standards institutes of 161 countries, one member per country. ISO develops and maintains consensus standards in many areas including sterilization. Often, ISO standards are adopted by countries and may be mandated by local governments. Technical Committee 198 develops and maintains standards related to Sterilization. AAMI AORN CDC ISO 3M Sterilization 5
8 Standards Practice Confidence in Sterilization with the Core Four. 1 2 Equipment Monitoring Load Monitoring Equipment Monitoring is a way to find out whether or not your sterilizer is doing its job properly. To monitor dynamicair-removal steam sterilizers, you begin each day with a Bowie-Dick type test to detect air leaks, inadequate air removal, inadequate steam penetration and the presence of non-condensable gases, any of which can compromise sterility. 3M Comply Bowie-Dick Plus Test Pack with Early Warning Test Sheet Indicates problems due to air leaks or inadequate vacuum during the air removal test cycle. Early Warning Test Sheet provides advance notice of sterilizer problem. Chemical indicator ink retains final result so test sheet can be filed for quality assurance records and later compared to current results if a change in sterilizer performance occurs. Yellow to dark brown/black indicator ink color change is easy to interpret. Putting Standards into Practice (1) The Bowie-Dick test should always be run in a warm sterilizer to avoid false failures. (2) Place your Bowie-Dick on the bottom shelf of the cart, over the drain, in an empty sterilizer. See product description on page 12. Load Monitoring is the process by which a load is monitored and released based on the result of a biological indicator (BI) in a process challenge device (PCD). Only a BI can detect the actual killing of microbial spores inside the sterilizer. If all spores die inside the BI, you have assurance that other infectious organisms have also died inside the sterilizer. For non-implant loads, may use a Class 5 integrating indicator PCD. 3M Attest Rapid 5 Steam-Plus Test Pack Includes a 3M Attest Rapid Readout biological indicator (BI) that provides results in three hours and a 3M Comply (SteriGage ) moving-front Class 5 Integrating Indicator. Meets AAMI ST79:2006/A1:2008/A2:2009 steam sterilization guidelines for process challenge device load monitoring requirements of implants. Reduces quarantine time by 88% providing BI results in 3 hours compared to 24 hour BIs. Enables you to make decisions and take action prior to surgery, reducing the risk and cost associated with recalls and surgical infections. Putting Standards into Practice (1) A positive control should be incubated each day a test BI is incubated in each 3M Attest Auto-reader. (2) If a test BI is positive, and the cause of the failure is not immediately identifiable, all items from that load and all items from loads processed since the last load with a negative BI result should be recalled and reprocessed. (3) Loads containing implants should be quarantined until the BI results are known. See product description on page M Sterilization
9 3 4 Pack Monitoring Exposure Monitoring Products Pack Monitoring is defined as the use of chemical indicators for internal monitoring of packs, trays, containers and peel pouches. Internal pack monitoring verifies that the sterilant has penetrated to the point of placement of the chemical indicator in the pack and confirms that specific exposure conditions have been met. 3M Comply (SteriGage ) Chemical Integrator Conforms to ANSI/AAMI/ISO :2005 Class 5 Integrating Indicator performance requirements which ensures the response correlates with a BI at three time/ temperature relationships under ideal steam sterilization conditions. For use in all F steam sterilization cycles which eliminates the potential error of selecting the incorrect, cycle-specific, emulating indicator and reduces your chemical indicator inventory. Migrating moving front style ink technology provides instant Accept or Reject results at a glance that do not require color interpretation. A study is available that shows higher reading accuracy than color-change indicators. Confirmed by BSI, a leading global independent Product Testing Services Company, to meet the performance requirements of ISO :2005. Putting Standards into Practice (1) Place an integrator in the geometric center of each pack, peel pouch or tray to be to be steam sterilized. In rigid containers, place an integrator in two opposite corners of each level. In multi-level wrapped containers supplied by the manufacturer, place an integrator in the center of each level. (2) If a pack fails, but the BI was negative, you could decide to issue the remaining packs from the load. If the BI results were not available when the pack failure was discovered, the load contents should be quarantined until the BI results are known. See product description on page 13. Exposure Monitoring Products are a way for sterilizer operators to know at a glance whether packs have been exposed to the sterilization process. It assures the operator handling the processed items that the pack has been exposed to the sterilization process without the need to open the pack. 3M Comply Steam Indicator Tapes Adhesives are designed specifically for disposable or reusable wraps. 3M Comply 1222 Steam Indicator Tape for all wraps. 3M Comply 1255 Steam Indicator Tape for disposable wraps. Adhesive seals packs securely. Backing stretches to minimize tape pop-off during sterilization. Can be written on or labeled with preprinted labels such as the 3M Comply Sterilization Load Labels. Putting Standards into Practice (1) Use an external chemical indicator on the outside of each package. (2) If a package allows for visual inspection of an internal indicator, such as those with paper plastic packaging, an external indicator is not required. See product description on page 19. Ask your 3M Sales Professional how 3M can recognize and support your facility s efforts to monitor the sterilization processes according to AAMI, AORN and CDC Standards and Recommended Practices. 3M Sterilization 7
10 Rapid Readout Biological Indicators Load Control Rapid Readout Biological Indicators and Test Packs Results in one hour (1291), three hours (1292) or four hours (1294). Each test pack contains a 3M Attest Rapid Readout Biological Indicator Test packs present a challenge to the sterilization process equivalent to the AAMI recommended towel pack Make decisions and take appropriate action before surgery Every-Load-Monitoring and quarantining can eliminate recalls Malfunctioning sterilizers can be repaired and put back into service quickly The 3M Attest Rapid Readout Biological Monitoring System can help reduce the costs associated with fighting infections a cost measured in both dollars and time spent 3M Attest Rapid Readout Biological Indicator for 132 C (270 F) Gravity Displacement Steam Sterilization 1291* Steam Biological Indicator (Blue cap) 50 each/box 4 boxes/case 3M Attest Rapid Readout Biological Indicators and Test Packs for 121 C (250 F) Gravity and 132 C (270 F) Vacuum-Assisted Steam Sterilization 1292* Steam Biological Indicator (Brown cap) 50 each/box 4 boxes/case 1296* Steam Biological Test Pack (25 controls) 25 packs/box 1 box/case 1296F* Steam Biological Test Pack (controls) 25 packs/box 1 box/case *Must be used in conjunction with 3M Attest 290 Auto-reader 3M Attest Rapid 5 Steam-Plus Test Pack Monitors 132 C (270 F), 4 minute vacuum-assisted and 121 C (250 F), 30 minute gravity displacement steam sterilization processes. Each pack contains a 3M Attest 1292 Rapid Readout Biological Indicator and a 3M Comply SteriGage 1243 Steam Chemical Integrator ** Steam Plus Test Pack 16 each/box 4 boxes/case (16 controls/box) 41382F** Steam Plus Test Pack 16 each/box 4 boxes/case (4 controls/box) **Must be used in conjunction with 3M Attest 290 Auto-reader 3M Attest Rapid Readout Biological Indicators and Test Packs for Ethylene Oxide (EO) Sterilization 1294*** EO Biological Indicator (Green cap) 50 each/box 4 boxes/case 1298*** EO Test Pack (25 controls) 25 packs/box 2 boxes/case 1298F*** EO Test Pack (5 controls) 25 packs/box 2 boxes/case ***Must be used in conjunction with 3M Attest 290G Auto-reader 8 3M Sterilization
11 Rapid Readout Biological Indicators Auto-readers For use with Attest Rapid Readout Biological Indicators 3M Attest 290 and 290G Auto-readers do not require time-consuming calibration Audible alarm sounds for improved monitoring Do not require any routine maintenance 120V nominal voltage required 3M Attest 290 Auto-readers 290 Auto-reader for steam, for use with 1 unit/box 1 box/case Attest Rapid Readout Biological Indicators for Steam 1291, and 1292, 60 C (140 F) 290G Auto-reader for EO, for use with Attest 1 unit/box 1 box/case Rapid Readout Biological Indicator for EO 1294, 37 C (98.6 F) 3M Attest Monitoring Interface for Software 3M Attest Monitoring Interface software module provides automatic, real-time documentation of 3M Attest Rapid Readout Biological Indicators by connecting the 3M Attest Auto-reader directly to Sterile Processing Microsystems SPM Asset Management Software. It provides hospitals with the trusted, gold standard in monitoring sterilization processes with instant access to results and other sterilization load documentation. 3M, in collaboration with Materials Management Microsystems, Inc. developed this interface software product to improve the accuracy and consistency of quality control processes. SPM is a comprehensive, computerized asset management system for Sterile Processing. It is designed to work on a network of computers and uses bar-code technology to track the location and movement of instruments sets throughout the processing and delivery cycle. SPM offers a guaranteed return on investment through productivity improvement. Several additional SPM modules are available to expand functionality of the system. Automatic, real-time documentation of 3M Attest Rapid Readout Biological Indicator results Supports the transition to paperless electronic record keeping Facility-wide availability of results Facilitates the recall process How SPM Software with 3M Attest Monitoring Interface works Monitor loads using 3M Attest Rapid Readout Biological Indicators Enter 3M Attest Rapid Readout BI test and control lot numbers into SPM Software and incubate BIs in the 3M Attest Auto-reader Access real-time 3M Attest Rapid Readout BI results at all networked workstations running SPM Software 3M Sterilization 9
12 Biological Indicators Load Control Biological Indicators and Test Packs Biological indicator vials are easy to use and interpret with visual color readout in 24 hours (1261) or 48 hours (1262/1264) Test packs present a challenge to the sterilization process equivalent to the AAMI recommended packs Each test pack contains a 3M Attest 1262 or 1264 Biological Indicator 3M Attest Biological Indicators for 132 C (270 F) Gravity Displacement Steam Sterilization 1261 Steam Biological Indicator (Blue cap) 100 each/box 4 boxes/case 1261P Steam Biological Indicator (Blue cap) 25 each/box 4 boxes/case 3M Attest Biological Indicators for 121 C (250 F) Gravity Displacement and 132 C (270 F) Vacuum-assisted Steam Sterilization 1262 Steam Biological Indicator (Brown cap) 100 each/box 4 boxes/case 1262P Steam Biological Indicator (Brown cap) 25 each/box 4 boxes/case 1276 Steam Biological Test Pack 25 each/box 1 box/case (25 controls/box) 1276F Steam Biological Test Pack 25 each/box 1 box/case (5 controls/box) 3M Attest Steam-Plus Test Pack Each pack consists of an Attest 1262 Biological Indicator and a 3M Comply (SteriGage ) Steam Chemical Integrator Steam-Plus Test Pack 16 each/box 4 boxes/case (4 controls/box) 3M Attest Biological Indicators for Ethylene Oxide (EO) Sterilization 1264 EO Biological Indicator (Green cap) 100 each/box 4 boxes/case 1264P EO Biological Indicator (Green cap) 25 each/box 4 boxes/case 1278 EO Test Pack 25 each/box 2 boxes/case (25 controls/box) 1278F EO Test Pack 25 each/box 2 boxes/case (5 controls/box) 10 3M Sterilization
13 Biological Indicators Biological Indicator Monitoring Starter Kit Everything you need for effective monitoring of the steam sterilization process. Consists of one roll of 3M Comply N Indicator Tape, one box of 3M Attest 1262P Biological Indicators, one 3M Attest 116 Incubator, one bag of 3M Comply (SteriGage ) 1243B Chemical Integrators, one 3M Attest A Log Book and Wall Chart. 3M Attest Biological Indicator Monitoring Starter Kit 115 Monitoring Kit 1 each/box 1 box/case Biological Indicator Incubators Attest Incubators provide optimal conditions for accurate readout of Attest Biological Indicators. Convenient, 14- or 28-vial capacity Dry-block design pre-set to proper incubation temperature 3M Attest Biological Indicator Incubators vial (round), 56 C (Steam), 120 nominal 1 each/box 1 box/case voltage required, V acceptable vial (round), 37 C (EO), 120 nominal 1 each/box 1 box/case voltage required, V acceptable vial (2-tier), 56 C (Steam), 120 nominal 1 each/box 1 box/case voltage required, V acceptable vial (2-tier), 37 C (EO), 120 nominal 1 each/box 1 box/case voltage required, V acceptable vial (2-tier), 37 C/56 C (EO/Steam), 1 each/box 1 box/case 120 nominal voltage required, V acceptable 3M Sterilization 11
14 Biological Bowie-Dick Indicators Test Packs Load Control Bowie-Dick Plus Test Pack with Early Warning Test Sheet The 3M Comply Bowie-Dick Plus Test Pack features the Early Warning Test Sheet that identifies potential air leaks or vacuum pump failures before they appear on the Comply Bowie-Dick Test Sheet. 3M Comply Bowie-Dick Plus Test Pack with Early Warning Test Sheet 00135* Bowie-Dick Plus Test Pack with 20 packs/box 4 boxes/case Early Warning Test Sheet *Has equivalent performance to the Bowie-Dick towel pack cited in ANSI/AAMI ST79. Bowie-Dick Type Test Packs and Sheets Designed for dynamic-air-removal sterilizers to test the efficacy of the vacuum system to remove air from the sterilizer chamber and to detect leaks in the system that would allow air into the chamber. Comply Bowie-Dick Test Packs make testing steam penetration and air removal, as well as detecting air leaks, more convenient and cost effective Designed to give results equivalent to those obtainable by the Bowie and Dick protocol Preassembled packs reduce both labor and material costs Indicator pattern is easy to read and interpret 3M Comply Bowie-Dick Type Test Pack 1233* Bowie-Dick Disposable Test Pack 6 packs/bag 5 bags/case 3M Comply Bowie-Dick Test Sheet Bowie-Dick Internal Steam Indicator Sheet 50 sheets/box 5 boxes/case *Has equivalent performance to the Bowie-Dick towel pack cited in ANSI/AAMI ST M Sterilization
15 Class 5 Chemical Integrators Steam Chemical Integrator Test Pack Pack consists of a 3M Comply 1243 (SteriGage ) Steam Chemical Integrator in a small test pack of porous substrate with a moisture impervious, quality disposable wrap. Test pack presents a challenge to the sterilization process equivalent to the AAMI recommended towel pack 3M Comply (SteriGage ) Steam Chemical Integrator Test Pack (AAMI Class 5) Test Pack with Comply (SteriGage) 16 packs/box 4 boxes/case Steam Chemical Integrator 3M Comply (SteriGage ) Steam Chemical Integrators 3M Comply SteriGage Steam Chemical Integrators offer immediate, accurate and easy-to-read method of monitoring sterilization process conditions inside each pack. For use in all steam sterilizers. Moving front style has accept/reject readout for instant results with easy interpretation, convenient small size for all packs with optional extenders available for fast retrieval from inner packs Conforms to ANSI/AAMI/ISO :2005 Class 5 Integrating Indicator performance requirements which ensures the response correlates with a BI at three time/temperature relationships under ideal steam sterilization conditions 3M Comply (SteriGage ) Steam Chemical Integrators (AAMI Class 5) 1243A Steam Chemical Integrator, moving front 500 each/bag 2 bags/case 5,1 cm x 1,9 cm (2" x 3/4") 1243B Steam Chemical Integrator, moving front 100 each/bag 10 bags/case 5,1 cm x 1,9 cm (2" x 3/4") 1243E Steam Chemical Integrator, moving front 1000 each/bag 1 bag/case with extender, 22,9 cm x 1,0 cm (9" x 3/8") 1240E Extender only 2500 each/bag 2 bags/case 19,1 cm x 1,0 cm (7-1/2" x 3/8") 3M Sterilization 13
16 Rapid Chemical Readout Integrators Biological and Indicators Load Control 3M Comply (Thermalog ) Steam Chemical Integrators 3M Comply Thermalog Steam Chemical Integrators offer an immediate, accurate and easy-to-read method of monitoring sterilization process conditions inside each pack. For use in all steam sterilizers. Moving front style has safe/unsafe readout for instant results with easy interpretation for fast retrieval from inner packs Conforms to ANSI/AAMI/ISO :2005 Class 5 Integrating Indicator performance requirements which ensures the response correlates with a Biological Indicator (BI) at three time/temperature relationships under ideal steam sterilization conditions 3M Comply (Thermalog ) Steam Chemical Integrators (AAMI Class 5) 2134MM Steam Chemical Integrator, moving front 250 units/pack 8 packs/case 10,16 cm x 1,91 cm (4" x 3/4") 3M Comply 6600 Steam Emulating Indicators Class 6 Emulating Indicators react to the critical variables required for steam sterilization for a specific sterilization cycle. A unique Class 6 Chemical Indicator is required for each time, temperature, and type of steam sterilization cycle. Unlike Class 5 Integrating Indicators, the response of Class 6 Emulating Indicators is not required to parallel the time/temperature response of a biological indicator. For use as an internal chemical indicator in 4 minute 132 C/270 F dynamicair-removal steam sterilization cycles. Class 6 Emulating Indicator as classified by ANSI/AAMI/ISO :2005 Plastic lamination protects sterilized items from potential ink transfer 3M Comply 6600 Steam Emulating Indicators (AAMI Class 6) M Comply Steam Emulating Indicator 250 items/pouch 20 pouches/case 4.25" x.25" 14 3M Sterilization
17 Rapid Readout Biological Chemical Indicators Steam Chemical Indicator-Plus Each strip has two purple ink bars that change color in sequence during exposure to saturated steam. A clear protective coating over the ink bars prevents the ink from touching items being sterilized. 3M Comply Steam Chemical Indicator-Plus Strips Short Form 132 C (270 F) Indicator, 200 each/box 20 boxes/case 1,5 cm x 10,8 cm (5/8" x 4-1/4"), for use in 270 F dynamic-air-removal and gravity sterilizers Long Form 132 C (270 F) Indicator, 200 each/box 20 boxes/case 1,5 cm x 18,7 cm (5/8" x 7-3/8"), for use in 270 F dynamic-air-removal and gravity sterilizers Short Form 121 C (250 F) Indicator, 200 each/box 20 boxes/case 1,5 cm x 10,8 cm (5/8" x 4-1/4"), for use in 250 F gravity sterilizers Steam Chemical Indicators 3M Comply Chemical Indicators offer distinct color change to indicate process results inside each pack. Indicator changes color to dark brown/black when exposed to steam sterilization. For use in all steam sterilizers. 3M Comply Steam Chemical Indicator Strip Long strip of chemical indicator ink printed on perforated-style strip. Allows full- or half-length use for different pack sizes Steam Chemical Indicator Strip 240 each/box 8 boxes/case 1,5 cm x 20 cm (5/8" x 8") *ISO :2005 Class 4 testing is underway. 3M Comply Steam Chemical Indicator Strips Chemical indicator printed as a block on short or long strips Long Form 250 each/box 20 boxes/case 1,5 cm x 22 cm (5/8" x 8-1/2") Short Form 250 each/box 20 boxes/case 1,5 cm x 11 cm (5/8" x 4-1/4") 00109A Short Form Economy Pack 1000 each/box 4 boxes/case 1,5 cm x 11 cm (5/8" x 4-1/4") 3M Sterilization 15
18 Rapid Chemical Readout Indicators Biological Indicators Load Control Vapor Hydrogen Peroxide Chemical Indicator An internal pack chemical indicator for use in STERRAD Sterilization Processes (Models 50, 100S, and 100). Indicator changes from blue to pink when exposed to vapor hydrogen peroxide. Indicator color does not fade when exposed to light. 3M Comply Gas Plasma Chemical Indicator Strip 1248 Comply Gas Plasma Chemical Indicator 250 each/box 4 boxes/case Strip, 2,0 cm x 10 cm (13/16" x 4") Liquid Peracetic Acid Chemical Indicator Single-use chemical indicator for use in the Steris System 1 processor. Indicator changes from red (unprocessed) to lime green (processed) color for easy interpretation when exposed to the appropriate concentration of sterilant. Large size and distinct color for easy retrieval of the indicator from processor. 3M Comply Liquid Peracetic Acid Chemical Indicator 1249 Comply Liquid Peracetic Acid Chemical 50 each/bag 4 bags/case Indicator, 4,4 cm x 4,4 cm (1-3/4" x 1-3/4") 16 3M Sterilization
19 Rapid Readout Biological Chemical Indicators Ethylene Oxide Chemical Integrators 3M Comply (SteriGage ) Chemical Integrators offer an immediate, accurate and easy-to-read method of monitoring sterilization process conditions inside each pack. For use in EO/HCFC gas mixture sterilization cycles. Moving front style has accept/reject readout for instant results with easy interpretation, convenient small size for all packs with optional extenders available for easy retrieval from inner packs 3M Comply (SteriGage ) Ethylene Oxide (EO) Chemical Integrators 1244A EO Chemical Integrator, moving front, 500 each/bag 2 bags/case for gas mixture sterilizers, 5,1 cm x 1,9 cm (2" x 3/4") 1244B EO Chemical Integrator, moving front, 100 each/bag 10 bags/case for gas mixture sterilizers, 5,1 cm x 1,9 cm (2" x 3/4") 1244E EO Chemical Integrator, moving front, 1000 each/bag 1 bag/case with extender, for gas mixture sterilizers, 22,9 cm x 1,0 cm (9" x 3/8") 1240E Extender only 2500 each/box 2 bags/case 19,1 cm x 1,0 cm (7-1/2" x 3/8") Ethylene Oxide Chemical Indicator For use in 100% EO and EO/HCFC gas mixtures. Long stripe of chemical indicator ink printed on perforated-style strip. Allows full- or half-length use for different pack sizes. Indicator changes color from red to green when exposed to ethylene oxide sterilization conditions. 3M Comply Ethylene Oxide (EO) Chemical Indicator Strip 1251 EO Chemical Indicator Strip 240 each/box 1 boxes/case 1,5 cm x 20 cm (5/8" x 8") 3M Sterilization 17
20 Rapid Chemical Readout Indicators Biological Indicators Load Control Instrument Protectors Protect sharp-pointed surgical instruments from damage and reduce possibility of pouch puncture during sterilization and handling. Indicators on the protectors verify steam or EO gas processing. 3M Comply Instrument Protectors ,1 cm x 12,8 cm (2" x 5") 100/pack 10 packs/case ,9 cm x 16,8 cm (3-1/2" x 6-5/8") 100/pack 10 packs/case cm x 24 cm (5-1/2" x 9-1/2") 100/pack 10 packs/case Steam Sterilization Indicator Labels Peel-off, pressure-sensitive labels for hard-surfaced items such as unwrapped glass or metal. 3M Comply Chemical Indicator Label Color changes from purple to green during steam sterilization Steam For use in steam sterilizers 1000 labels/roll 12 rolls/case 1,9 cm x 3,2 cm (3/4" x 1-1/4") 1 roll/box Dry Heat Chemical Indicator Sterilization monitor for dry heat sterilizers. Indicator changes color from tan to black within 10 minutes at 160 C (320 F) during exposure to dry heat processing. 3M Comply Dry Heat Chemical Indicator Strip Dry Heat Chemical Indicator Strip 250 each/box 10 boxes/case 1,5 cm x 11 cm (5/8" x 4-1/4") 18 3M Sterilization
21 Rapid Readout Biological Indicator Indicators Tapes Indicator Tapes for Steam Sterilization A reliable steam indicator tape that provides immediate identification of processed items and also serves as a closure to seal sterilization packs. The chemical indicator lines will turn dark when exposed to a steam sterilization process. Class I: conforms to ANSI/AAMI/ISO :2005 3M Comply Indicator Tapes for Steam Sterilization* N 1,25 cm x 55 m (1/2" x 60 yds.), Tan - 36 rolls/case N 2,5 cm x 55 m (1" x 60 yds.), Tan - 18 rolls/case N 5 cm x 55 m (2" x 60 yds.), Tan - 10 rolls/case N 1,9 cm x 55 m (3/4" x 60 yds.), Tan - 24 rolls/case *Contains Dry Natural Rubber Steam Indicator Tapes for Disposable Wraps A reliable steam indicator tape specifically designed for disposable wraps that provides immediate identification of processed items and also serves as a closure to seal sterilization packs. The chemical indicator lines will turn dark when exposed to a steam sterilization process. Class I: conforms to ANSI/AAMI/ISO :2005 3M Comply Steam Indicator Tapes for Disposable Wraps* N 2,5 cm x 55 m (1" x 60 yds.), Blue - 18 rolls/case N 1,9 cm x 55 m (3/4" x 60 yds.), Blue - 24 rolls/case *Contains Dry Natural Rubber Indicator Tapes for EO Sterilization A reliable ethylene oxide gas indicator tape that provides immediate identification of processed items and also serves as a closure to seal sterilization packs. The chemical indicator lines will turn red when exposed to an EO sterilization process. Class I: conforms to ANSI/AAMI/ISO :2005 3M Comply Indicator Tapes for Ethylene Oxide (EO) Sterilization* ,25 cm x 55 m (1/2" x 60 yds.), Green - 36 rolls/case ,5 cm x 55 m (1" x 60 yds.), Green - 18 rolls/case ,9 cm x 55 m (3/4" x 60 yds.), Green - 24 rolls/case *Contains Dry Natural Rubber 3M Sterilization 19
22 Rapid Indicator Readout TapesBiological Indicators Load Control Indicator Tape for Vapor Hydrogen Peroxide Sterilization An external chemical indicator tape for use in STERRAD Sterilization Processes (Models 50, 100S, and 100). Indicator changes from blue to pink when exposed to vapor hydrogen peroxide. 3M Comply Gas Plasma Indicator Tape ,9 cm x 55 m (3/4" x 60 yds.), White - 24 rolls/case Indicator Tape Dispensers 3M Comply M52 Tape Dispenser with Tabber The Comply M52 Tape Dispenser with Tabber has a weighted base and is capable of handling three rolls of 1/2-inch, up to two rolls no wider than 1-inch, or one 2-inch roll of indicator tape. A tabber can be attached to the tape dispenser, which automatically folds a 1/4-inch length of tape up to a 1-inch roll width. M52 Heavy Duty - 1 each/case C22 Heavy Duty Tape Dispenser The C22 heavy duty tape dispenser is made of rugged, high-impact, durable plastic and is capable of handling two rolls of 1-inch wide indicator tape. C22 Heavy duty, holds 2 rolls - 2 each/case 20 3M Sterilization
23 Record Keeping Load Record Cards For steam and ethylene oxide (EO) gas sterilizers. Provides a permanent record of sterilizer use and work flow. 3M Comply Load Record Cards 1252 Steam Load Record Card 240 each/box 4 boxes/case 7,6 cm x 12,8 cm (3" x 5") 1253 EO Load Record Card 240 each/box 2 boxes/case 7,6 cm x 12,8 cm (3" x 5") Steam and EO Load Record Card 250 each/box 4 boxes/case 7,6 cm x 12,8 cm (3" x 5") Steam and EO Load Record Card 250 each/box 4 boxes/case 10,2 cm x 14 cm (4" x 5-1/2") Sterilization Integrator Load Record Card A single-use device that indicates whether materials within a pack or load have been exposed to conditions necessary for sterilization. The steam sterilization record cards can be used in all steam sterilization processes. 3M Comply (SteriGage ) Load Record Card 4171MM Integrator with Load Record Card Steam 100 each/box 1 box/case 3M Sterilization 21
24 Record Keeping Load Control Log Books, Envelopes and Record Charts Complete record keeping systems that maintain your sterilization process information and reduce record keeping time to just minutes each day. The preprinted log books put all the information you need to help you meet requirements at your fingertips. 3M Attest Envelopes, Sheets and Binders 1254E-A Sterilization Record Envelopes, 24,13 cm x 29,21 cm 100 each/pack 5 packs/case (9-1/2" x 11-1/2") with two load-contents columns, for Steam, Flash or Low Temperature Systems 1254S-A Sterilization Record Sheets, 21,59 cm x 27,94 cm 250 each/pack 4 packs/case (8-1/2" x 11") with two load-contents columns, for Steam, Flash or Low Temperature Systems 1254E-S Steam Sterilization Record Envelopes, 24,13 cm x 29,21 cm 100 each/pack 5 packs/case (9-1/2" x 11-1/2") with one column load-contents format 1254E-F Flash Sterilization Record Envelopes, 24,13 cm x 29,21 cm 100 each/pack 5 packs/case (9-1/2" x 11-1/2") with one column load-contents format 1254E-LT Low Temperature Sterilization Record Envelopes, 100 each/pack 5 packs/case 24,13 cm x 29,21 cm (9-1/2" x 11-1/2") with one column load-contents format 1254-A Sterilization Record System, binder with 50 each 1 each 1 each/case 1254E-A envelopes and 50 each 1254S-A sheets 1254B Sterilization Record Binder (order 1254E series envelopes 1 each 1 each/case and 1254S-A sheets separately) 3M Attest Log Books 1280-A Log Book for Steam, with 50 record charts, blue, use with 50 each/pack 1 pack/case Attest 1291 Rapid Readout BIs 1283-A Log Book for Steam, with 50 record charts, brown, use with 50 each/pack 1 pack/case Attest 1292 Rapid Readout BIs 1267-A Log Book for EO, with 50 record charts, green, use with 50 each/pack 1 pack/case Attest 1294 EO Rapid Readout BIs 1266 Log Book for Steam, with 50 record charts, use with 1 each/pack 1 pack/case Attest 1291 and 1292 Rapid Readout BIs 1266-A Log Book for Steam, with 50 record charts, use with 50 each/pack 1 pack/case Attest 1261 or 1262 BIs 1268 Log Book, with 50 record charts, 1 each/pack 1 pack/case use with all Low Temperature BI and CI products 1283 Log Book, with 50 record charts, 1 each/pack 1 pack/case use with all Glutaraldehyde Indicators 22 3M Sterilization
25 Record Keeping Label Gun System 3M Comply Label Gun 1256B Printing applicator prints and applies 1 each/box 1 box/case labels directly where needed 3M Event Related Sterilization Record Labels* d 1269B Blue labels 1125 labels/roll 1 box/case 2,85 cm x 1,58 cm (1-1/8" x 5/8") 12 rolls/box 1269BL Black labels 1125 labels/roll 1 box/case 2,85 cm x 1,58 cm (1-1/8" x 5/8") 12 rolls/box 1269G Green labels 1125 labels/roll 1 box/case 2,85 cm x 1,58 cm (1-1/8" x 5/8") 12 rolls/box 1269R Red labels 1125 labels/roll 1 box/case 2,85 cm x 1,58 cm (1-1/8" x 5/8") 12 rolls/box 3M Sterilization Record Labels* Expires 1257B Blue labels 1125 labels/roll 1 box/case 2,85 cm x 1,58 cm (1-1/8" x 5/8") 12 rolls/box 1257BL Black labels 1125 labels/roll 1 box/case 2,85 cm x 1,58 cm (1-1/8" x 5/8") 12 rolls/box 1257G Green labels 1125 labels/roll 1 box/case 2,85 cm x 1,58 cm (1-1/8" x 5/8") 12 rolls/box 1257R Red labels 1125 labels/roll 1 box/case 2,85 cm x 1,58 cm (1-1/8" x 5/8") 12 rolls/box Sterilization Record Labels* Blank 1257W White labels 1125 labels/roll 1 box/case 2,85 cm x 1,58 cm (1-1/8" x 5/8") 12 rolls/box *Transitioning to Latex-Free Product 3M Sterilization 23
26 Clean and Disinfect Load Control Multi-Enzyme Detergent An effective multi-enzyme detergent used for cleaning metal and plastic medical instruments, including flexible and rigid endoscopes. Effectively digests human secretions after immersion for only 2 10 minutes. Made with biodegradable materials. 3M Rapid Multi-Enzyme Detergent B 5 Liter Bottle 3 each/case case Glutaraldehyde Monitors Each monitor consists of a plastic strip with a black-framed chemical reaction pad. Pad changes from white to yellow when immersed in glutaraldehyde solutions with adequate concentration. 3M Comply Glutaraldehyde Monitors, 1.5%, 1.8%, 2.1% Designed to test glutaraldehyde solutions with stated manufacturer's Minimum Effective Concentration (MEC) values. Indicates safe solutions when above 1.5%, 1.8% or 2.1% MECs. 3983MM 1.5% MEC* 60 monitors/bottle 2 bottles/case % MEC* 60 monitors/bottle 2 bottles/case % MEC* 60 monitors/bottle 2 bottles/case *Test strips are brand specific. Please contact 3M for details 24 3M Sterilization
27 Sterilization Equipment 100% Ethylene Oxide rs/aerators 3M Steri-Vac Models 5XL and 8XL are 100% ethylene oxide (EO) gas sterilizers/ aerators available with two pre-programmed cycles. (Warm Cycle: 55 C, ~2.75 hrs exposure. Cool Cycle 37 C, ~4.75 hrs exposure.) Physical cycle parameters are displayed on video display with print capability. Designed for safety, the single unitdose 100% EO cartridge is punctured inside the chamber only when proper chamber negative-pressure conditions are achieved. The built-in aeration cycle allows a single chamber process. Available in single or double door pass-through design. Cat. No. Description Shipping 3M Steri-Vac 5XL r/aerator The 5XL sterilizer features 4.8 cu.ft. of usable space in the chamber. The software-controlled electronic design is easy to use with built in display of cycle status. Relative humidity sensor monitors sterilization chamber RH during preconditioning phase. 5XL r/aerator 1 unit/case Exterior: 59 cm (H) x 76 cm (W) x 90 cm (D) 23" (H) x 30" (W) x 35" (D) Chamber: 38 cm (H) x 43 cm (W) x 83 cm (D) 15" (H) x 17" (W) x 34"(D) 3M Steri-Vac 8XL r/aerator Like the 5XL, the sterilizer allows full usage of the rectangular chamber, is easy to use and provides continuous display of the cycle status. The 8XL provides a 7.9 cu. ft. chamber. The relative humidity feature continuously monitors, maintains and documents the proper humidity in the sterilization chamber during the precondition phase. 8XL r/aerator 1 unit/case Exterior: 179 cm (H) x 94 cm (W) x 109 cm (D) 70" (H) x 37" (W) x 43" (D) Chamber: 46 cm (H) x 51 cm (W) x 97 cm (D) 18-1/8" (H) x 20" (W) x 38" (D) Remote Display Panel The digital remote display option (RDP) allows hands-off operation and is available for both 5XL and 8XL models. Up to four Steri-Vac sterilizers can be connected to a single RDP. RDP Remote Display 1 unit/case 3M Sterilization 25
28 Sterilization Equipment Load Control Steri-Gas 100% Ethylene Oxide (EO) Gas Cartridges The easy-to-use, single dose 3M Steri-Gas EO cartridges are engineered for safety. The cartridge contains 3.5, 4.5 or 6 oz. of EO depending on the model Steri-Vac r used. Precise usage of EO with single-dose cartridges means no waste of sterilant With 3M Steri-Gas Cartridges, operators have no bulky, heavy gas tanks to handle, and no hoses, valves and filters to adjust or replace The cartridges do not contain CFCs or HCFCs 3M Steri-Gas Cartridges gram Cartridge for Models 400C, 4XL and 5XL 12 each/box 4 boxes/case gram Cartridge for Model 400B 12 each/box 4 boxes/case gram Cartridge for Model 8XL 12 each/box 4 boxes/case Ethylene Oxide (EO) Monitoring Badge 3M EO personal monitoring badges are lightweight and are designed with EO-sensitive material. Clips to lapel or pocket near breathing zone for passive monitoring of individual during a work shift. The monitor is mailed for analysis and a report is provided back to the user with results. The employer is notified immediately of any result that exceeds permissible exposure limits. 3M Ethylene Oxide (EO) Monitoring Badge 3550 EO Monitoring Badge - 5 each/case Printer Papers Cat. No. Description Shipping 3M Steri-Vac Printer Papers 1215A Printer Paper, 51 mm (2") wide, 2 rolls/case for models 400B & 400C (discontinued models) 1216A Printer Paper, 60 mm (2-3/8") wide, 2 rolls/case for 4XL and 5XL (with serial number below ) 1217 Printer Paper, 79 mm (3-1/8") wide, 2 rolls/case for 8XL and 5XL (with serial number above ) 26 3M Sterilization
29 Sterilization Equipment Transfer Cart A stainless steel transfer cart developed to assist operators to move, lift or lower materials and supplies around the Sterile Processing Department. Fully programmable, state-of-the-art motor controller allows for multiple adjustments to fit user s needs Drifting/coasting of load is eliminated due to electromagnetic brake and drive screw design Battery operated with built-in, self-monitoring recharger; two rechargeable batteries provided Two table sizes available Cat. No. Description Shipping 3M Transfer Cart 6010 Vestil Loading Cart 1 cart/case Table size: 61 cm x 48 cm (24" x 19") or 76 cm x 59 cm (30" x 23.5") Raised height: 145 cm (57") Holding capacity: 68 kg (175 lbs) 3M Sterilization 27
30 Sterilization Equipment Load Control Aerator The 3M Model XL aeration cabinet circulates warm, filtered air in its 5 cu. ft. chamber. Designed for compatibility with 3M Steri-Vac rs. Two selectable aeration temperatures, 37 C (99 F) or 55 C (131 F) Modular system for versatility Space efficient A door lock prevents unauthorized access Cat. No. Description Shipping 3M Steri-Vac XL Aerator XL Aerator 1 unit/case Exterior: 62 cm (H) x 78 cm (W) x 93 cm (D) 24-3/8" (H) x 30-3/4" (W) x 36-5/8" (D) Chamber: 41 cm (H) x 46 cm (W) x 84 cm (D) 16-1/8" (H) x 18-1/8" (W) x 33" (D) Ethylene Oxide (EO) Abator The 3M Abator removes EO gas exhausted from 3M Steri-Vac rs and Aerators, converting it into CO2 and water vapor. At normal operating temperatures and concentrations, removal efficiency is % when EO concentrations are greater than (>)100ppm. Works automatically with sterilization system Interfaces with up to two sterilizers or two aerators Cat. No. Description Shipping 3M Ethylene Oxide (EO) Abator 50 Abator 1 unit/case 81 cm (H) x 92 cm (W) x 107 cm (L) 32" (H) x 36" (W) x 42" (L) 28 3M Sterilization
31 Sterilization Packaging Packaging 3M Steri-Lok Peel Open Packages for Ethylene Oxide (EO) Sterilization ,9 cm x 24,8 cm (3-7/8" x 9-3/4") 250 each/box 4 boxes/case ,9 cm x 61 cm (3-1/8" x 24") 250 each/box 4 boxes/case ,8 cm x 33 cm (7" x 13") 250 each/box 2 boxes/case ,8 cm x 38 cm (11-3/4" x 14-7/8") 250 each/box 2 boxes/case cm x 45,7 cm (15-3/4" x 18") 250 each/box 2 boxes/case 3M Sterilization 29
32 Index Index by Catalog Number Catalog Number Product Name Page Number M Comply Steam Chemical Indicator Strip M Comply Steam Chemical Indicator Strip A 3M Comply Steam Chemical Indicator Strip M Comply Steam Chemical Indicator-Plus Strip M Comply Steam Chemical Indicator-Plus Strip M Comply Steam Chemical Indicator-Plus Strip M Comply Bowie-Dick Test Sheet M Comply Bowie-Dick Plus Test Pack with Early Warning Test Sheet M Comply Chemical Indicator Label M Comply Dry Heat Chemical Indicator Strip M Steri-Gas Cartridge M Steri-Gas Cartridge M Steri-Gas Cartridge 26 5XL 3M Steri-Vac 5XL r/aerator 25 8XL 3M Steri-Vac 8XL r/aerator M Ethylene Oxide (EO) Abator M Attest Biological Indicator Monitoring Starter Kit M Attest Biological Indicator Incubator M Attest Biological Indicator Incubator M Attest Biological Indicator Incubator M Attest Biological Indicator Incubator M Attest Biological Indicator Incubator M Attest 290 Auto-reader for Steam 9 290G 3M Attest 290G Auto-reader for Ethylene Oxide (EO) A 3M Steri-Vac Printer Paper A 3M Steri-Vac Printer Paper M Steri-Vac Printer Paper N 3M Comply Indicator Tape for Steam Sterilization N 3M Comply Indicator Tape for Steam Sterilization N 3M Comply Indicator Tape for Steam Sterilization N 3M Comply Indicator Tape for Steam Sterilization M Sterilization
33 Index Index by Catalog Number Catalog Number Product Name Page Number M Comply Indicator Tape for Ethylene Oxide (EO) Sterilization M Comply Indicator Tape for Ethylene Oxide (EO) Sterilization M Comply Indicator Tape for Ethylene Oxide (EO) Sterilization M Comply Gas Plasma Indicator Tape M Comply Bowie-Dick Type Test Pack E 3M Comply (SteriGage ) Integrator Extender 13 & A 3M Comply (SteriGage ) Steam Chemical Integrator B 3M Comply (SteriGage ) Steam Chemical Integrator E 3M Comply (SteriGage ) Steam Chemical Integrator A 3M Comply (SteriGage ) Ethylene Oxide (EO) Chemical Integrator B 3M Comply (SteriGage ) Ethylene Oxide (EO) Chemical Integrator E 3M Comply (SteriGage ) Ethylene Oxide (EO) Chemical Integrator M Comply Gas Plasma Chemical Indicator Strip M Comply Liquid Peracetic Acid Chemical Indicator M Comply Steam Chemical Indicator Strip M Comply Ethylene Oxide (EO) Chemical Indicator Strip M Comply Load Record Card (Steam) M Comply Load Record Card (EO) A 3M Sterilization Record System B 3M Sterilization Record Binder E-A 3M Attest Sterilization Record Envelopes E-F 3M Attest Steam Flash Sterilization Record Envelopes E-LT 3M Attest Low Temperature Sterilization Record Envelopes E-S 3M Attest Steam Sterilization Record Envelopes S-A 3M Attest Sterilization Record Sheets N 3M Comply Steam Indicator Tape for Disposable Wraps N 3M Comply Steam Indicator Tape for Disposable Wraps B 3M Comply Label Gun B Sterilization Record Labels Expires, Blue BL Sterilization Record Labels Expires, Black G Sterilization Record Labels Expires, Green 23 3M Sterilization 31
34 Index Index by Catalog Number Catalog Number Product Name Page Number 1257R Sterilization Record Labels Expires, Red W Sterilization Record Labels Blank, White M Attest Biological Indicator for 132 C (270 F) Gravity Displacement Steam Sterilization P 3M Attest Biological Indicator for 132 C (270 F) Gravity Displacement Steam Sterilization M Attest Biological Indicator for 121 C (250 F) Gravity and 132 C (270 F) Vacuum-assisted Steam Sterilization P 3M Attest Biological Indicator for 121 C (250 F) Gravity and 132 C (270 F) Vacuum-assisted Steam Sterilization M Attest Biological Indicator for Ethylene Oxide (EO) Sterilization P 3M Attest Biological Indicator for Ethylene Oxide (EO) Sterilization M Steam Log Book A 3M Attest Log Book for use with Attest BI 1261 or A 3M Attest RRBI Log Book for use with Attest RRBI M Low Temperature Log Book B Event Related Sterilization Record Labels d, Blue BL Event Related Sterilization Record Labels d, Black G Event Related Sterilization Record Labels d, Green R Event Related Sterilization Record Labels d, Red M Attest Biological Indicator Test Pack for 121 C (250 F) Gravity and 132 C (270 F) Vacuum-Assisted Steam Sterilization F 3M Attest Biological Indicator Test Pack for 121 C (250 F) Gravity and 132 C (270 F) Vacuum-Assisted Steam Sterilization M Attest Biological Indicator Test Pack for Ethylene Oxide (EO) Sterilization F 3M Attest Biological Indicator Test Pack for Ethylene Oxide (EO) Sterilization A 3M Attest RRBI Log Book for use with Attest RRBI M Glutaraldehyde Log Book A 3M Attest RRBI Log Book for use with Attest RRBI M Attest Rapid Readout Biological Indicator for 132 C (270 F) Gravity Displacement Steam Sterilization M Attest Rapid Readout Biological Indicator for 121 C (250 F) Gravity and 132 C (270 F) Vacuum-assisted Steam Sterilization M Attest Rapid Readout Biological Indicator for Ethylene Oxide (EO) Sterilization M Attest Rapid Readout Biological Indicator Test Pack for 121 C (250 F) Gravity and 132 C (270 F) Vacuum-assisted Steam Sterilization M Sterilization
35 Index Index by Catalog Number Catalog Number Product Name Page Number 1296F 3M Attest Rapid Readout Biological Indicator Test Pack for 121 C (250 F) Gravity and 132 C (270 F) Vacuum-assisted Steam Sterilization M Attest Rapid Readout Test Pack for Ethylene Oxide (EO) Sterilization F 3M Attest Rapid Readout Test Pack for Ethylene Oxide (EO) Sterilization M Comply Instrument Protector M Comply Instrument Protector M Comply Instrument Protector MM 3M Comply (Thermalog ) Steam Chemical Integrators M Ethylene Oxide (EO) Monitoring Badge MM 3M Comply Glutaraldehyde Monitor, 1.5% M Comply Glutaraldehyde Monitor, 1.8% M Comply Glutaraldehyde Monitor, 2.1% M Comply (SteriGage ) Steam Chemical Integrator Test Pack M Attest Steam-Plus Test Pack M Attest Biological Indicators and Test Pack F 3M Attest Biological Indicators and Test Pack MM 3M Comply Load Record Card M Transfer Cart M Comply 6600 Steam Emulating Indicators M Comply Load Record Cards (Steam and EO) M Comply Load Record Cards (Steam and EO) B 3M Rapid Multi-Enzyme Detergent, 5 liter bottle M Steri-Lok Peel Open Package for Ethylene Oxide (EO) Sterilization M Steri-Lok Peel Open Package for Ethylene Oxide (EO) Sterilization M Steri-Lok Peel Open Package for Ethylene Oxide (EO) Sterilization M Steri-Lok Peel Open Package for Ethylene Oxide (EO) Sterilization M Steri-Lok Peel Open Package for Ethylene Oxide (EO) Sterilization 29 C22 C-22 Heavy Duty Tape Dispenser 20 M52 3M Comply M52 Tape Dispenser with Tabber 20 RDP Remote Display 25 XL 3M Steri-Vac XL Aerator 28 3M Sterilization 33
36 Notes 34 3M Sterilization
37 Index Notes 3M Sterilization 35
38 Infection Prevention Division 3M Health Care 3M Center, Building 275-4E-01 St. Paul, MN U.S.A Infection Prevention Division 3M Canada Post Office Box 5757 London, Ontario N6A4TI Canada M is a trademark of 3M. Please recycle. Printed in U.S.A. 3M 2009,2011. All rights reserved M, Attest, Comply, Steri-Gage, Steri-Gas, Steri-Lok and Steri-Vac are trademarks of 3M. Steris System 1 is a registered trademark of Steris Corporation. STERRAD is a registered trademark of Johnson & Johnson, Inc. SPM is a trademark of Materials Management Microsystems.
Putting Confidence in Your Hands.
Putting Confidence in Your Hands. 3M Sterilization Products and Services Full Line Catalogue 1 Trusted 3M Sterilization Solutions Equipment Monitoring Exposure Monitoring Pack Monitoring Load Monitoring
More informationBest Practice Monitoring for Sterile Processing Professionals
Best Practice Monitoring for Sterile Processing Professionals Sterile processing departments are faced with greater challenges than ever. Increasing demands for quick turnarounds. Pressure to streamline
More information3M Products and Services for Medical Sterilization Processes. Full Line Catalog. Medical
3M Products and Services for Medical Sterilization Processes Full Line Catalog Medical 3M Medical Sterilization Specialties 3M Medical Sterilization Specialties is a global leader in the manufacture and
More information3M Life Science Sterilization Product Portfolio More control. More confidence.
3M Life Science Sterilization Product Portfolio More control. More confidence. Solutions for medical device and pharmaceutical sterilization processes 3M Life Science Sterilization Product Portfolio Setting
More informationCool when it counts. 3M Steri-Vac Sterilizer/Aerator GS Series. For Health Care Facilities
Cool when it counts 3M Steri-Vac Sterilizer/Aerator GS Series For Health Care Facilities Stay cool under pressure with state of the art temperature and humidity monitoring and a touch screen cycle display
More informationWelcome! Thank you for attending today s meeting, it will begin shortly.
3M Sterile U Web Meeting January 20, 2011 Welcome! Thank you for attending today s meeting, it will begin shortly. How do I get a CE Certificate? Next week, all of today s meeting participants will be
More informationFAQFrequently. Asked Questions. Education & Training. 3M Sterilization Assurance Techline
Asked Questions 3M Sterilization Assurance Techline by Sandra Velte, BA, CSPDT FAQFrequently Objectives After completion of this self-study activity, the learner will be able to: 1. Develop a policy and
More informationMcKesson Sterilization Products
McKesson Sterilization Products Table of Contents Introduction Introduction... 3 Biological Indicators and Incubators Steam Integrator... 4 Sterilization Biological Indicator Vial...4 Self-Contained Biological
More informationINSTRUMENT CLEANING & STERILISATION FOAMING BATH FORMULATION. Surgistain. Rapid Multi-Enzyme Cleaner. Kimguard Sterile Wrap. Instrument brushes $32.
1Ltr Rapid Multi-Enzyme Cleaner Ÿ Proprietary combination enzyme Ÿ concentrate Ÿ Unparalleled combination of speed Ÿ and efficacy Ÿ Fully effective against proteins, Ÿ carbohydrates, lipids and Ÿ mucopolysaccharides
More informationThey can be used on washer-disinfectors, ultrasonic cleaners, surgical instruments and endoscopes. Page 5
Rev. 0 October 2017 Terragene offers a wide range of simple and effective products to precisely control the washing, hygiene and sterilization processes in veterinary clinics. Available in a variety of
More informationTechnical Data Monograph. VERIFY Assert Self-Contained Biological Indicators and VERIFY Assert STEAM Process Challenge Devices
Technical Data Monograph VERIFY Assert Self-Contained Biological Indicators and VERIFY Assert STEAM Process Challenge Devices Table of Contents 1. Introduction....3 2. Product Use Application...4 Device
More informationWelcome! How do I get a CE Certificate?
M Sterile U Network M Sterile U Web Meeting November 0, 0 Today s meeting times: 9:00 a.m., :00 a.m., and :00 p.m. Central Standard Time To hear audio, call 800-97-00 and enter access code 7 Phone lines
More informationRev. 1 May 2018 Terragene offers a range of effective and easy-to-handle products to control the washing, hygiene, disinfection and sterilization processes in medical diagnostic laboratories. Available
More informationANSI/AAMI ST79 A2:2009 Key Changes in the 2009 Amendment
3M Attest TM TM Products Sterile U Network T U T O R I A L S ANSI/AAMI ST79 A2:2009 Key Changes in the 2009 Amendment Background: A second amendment (A2:2009) to the Association for the Advancement of
More information8/23/2012. Continuing Education Contact Hours. How much of your formal education focused on sterilization or sterile processing?
Continuing Education Contact Hours The presenter is an employee of STERIS Corporation and receives no direct compensation other than normal salary for participation in this activity. STERIS Corporation
More information3M s Sterilization Tech Line FAQs Sandra Velte, BA, CSPDT
3M Sterile U Sterilization Assurance Continuing Education 3M s Sterilization Tech Line FAQs Sandra Velte, BA, CSPDT May 2013 Objectives After completion of this self-study activity, the learner will be
More informationFacility: Sterile Processing Assessment Date: CRITERIA ANSI/AAMI COMPLIANT Number Y N N/A Point of Use Gross contaminant is removed with
Point of Use 6.2-6.3 Gross contaminant is removed with water Instruments are sorted Sharps removed Instruments placed back in original container Un-used instruments placed in bottom of basket Towel placed
More informationSlide 1. Slide 2. Slide 3. Sponsored by Webber Training Inc. For more information contact Paul Webber
Slide 1 QUALITY ASSURANCE IN STERILIZATION Susan Hadfield Director, Sterile Processing Department Health Sciences Centre Winnipeg, Manitoba Hosted by Paul Webber (paul@webbertraining.com) A teleclass sponsored
More informationSpecialty Testing of Steam Sterilizers
Specialty Testing of Steam Sterilizers Nancy Chobin, RN, AAS, ACSP, CSPM, CFER 2017 Sterile Processing University, LLC. **This in-service has been Approved by the CBSPD for 1.5 CEUs. Objectives 1. To describe
More informationSterilization Policy. Georgia Regents Medical Center Policy Library. Policy Owner: Epidemiology POLICY STATEMENT
POLICY STATEMENT The ability to sterilize instruments and equipment for use during operative or other invasive procedures is critical to promoting successful patient outcomes and preventing infections.
More informationResponses to Questions for SYSTEM 1E Process Monitoring and Validation Webinar
Responses to Questions for SYSTEM 1E Process Monitoring and Validation Webinar MONITORING THE SYSTEM 1E PROCESSOR Q: I want to confirm that there is no need for a Biological Indicator (BI) and that use
More informationPRODUCT CATALOGUE. for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization
PRODUCT CATALOGUE for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization Bowie-Dick Simulation Test Batch and Process Monitoring Systems, Documentation
More informationTechnical Data Monograph. VERIFY All-In-One STEAM Reusable Test Pack
Technical Data Monograph VERIFY All-In-One STEAM Reusable Test Pack Table of Contents 1. Introduction...3 2. Product....3 Use Application...3 Device Description...3 VERIFY All-In-One STEAM Reusable Test
More informationPRODUCT CATALOGUE. for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization
PRODUCT CATALOGUE for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization Bowie-Dick Simulation Test Batch and Process Monitoring Systems, Documentation
More informationWhat Every Infection Preventionist Should Know About the Critical Issues in the Steam Sterilization Process
3M Attest Sterile U Web Meeting August 20, 2009 What Every Infection Preventionist Should Know About the Critical Issues in the Steam Sterilization Process Updated Aug 2009 by Martha Young Welcome! Facilitator:
More informationPackaging & Sterilization
Packaging & Sterilization Packaging & Sterilization 1 Dr. Norman Clinical Consultant General Sterilization Packaging System in Hospitals Sterilization Packaging System Disposable Reusable Crepe paper Woven
More informationInstructions for Validation of Autoclaves
Instructions for Validation of Autoclaves A. Validation of autoclaves may accomplished by the following methods: 1. Autoclave tape applied to the outside of all packs to validate that the correct temperature
More informationgke Steri-Record Testsets and PCDs for validation, process and batch monitoring of sterilization processes
gke Steri-Record Testsets and PCDs for validation, process and batch monitoring of sterilization processes Application Process Monitoring Systems (PMS) are process challenge devices that are used to test
More information6 Handling, collection, and transport of contaminated items General rationale Separation of waste and reusable items at point of
Contents Glossary of equivalent standards... ix Committee representation... xi Acknowledgments...xiii Foreword... xiv Introduction: Need for the recommended practice...1 1 Scope...5 1.1 General...5 1.2
More informationObjectives. The Perioperative Nurse s Role 6/24/2016. Instrument Processing & Sterilization Chesapeake Perioperative Consortium 2016
Instrument Processing & Sterilization Chesapeake Perioperative Consortium 2016 Ensuring our patients get clean, sterile instruments every time. Objectives Define the perioperative nurse and surgical tech
More informationQuality Control LOAD CONTROL. VERIFY Load Control Products. Use to monitor and release instrumentation with confidence RECORD KEEPING & LABELING
STERILITY ASSURANCE Use to monitor and release instrumentation with confidence VERIFY Load Control Products LOAD CONTROL PROCESS CONTROL PACK CONTROL EQUIPMENT CONTROL RECORD KEEPING & LABELING PRODUCT
More informationHygiene Monitoring. Chemical Indicators, BD-Test and Batch- Product Information. CI_01_Eng
Hygiene Monitoring Chemical Indicators, BD-Test and Batch- Control (PCD) Product Information CI_01_Eng verkauf@bag-healthcare.com service@bag-healthcare.com BAG-BD-Check II / BAG-BD-Check Disposable Bowie
More informationQuality Control EQUIPMENT CONTROL. Monitor critical performance characteristics of sterilization, decontamination or cleaning equipment
STERILITY ASSURANCE Monitor critical performance characteristics of sterilization, decontamination or cleaning equipment VERIFY Equipment Control Products EQUIPMENT CONTROL LOAD CONTROL PROCESS CONTROL
More informationAdvantages. Steam sterilization
Rev. 1 November 2016 Steam sterilization Sterilization is the total destruction of all microorganisms, whether or not pathogenic, and their spores. Moist heat in the form of saturated steam under pressure
More information6 Handling, collection, and transport of contaminated items General rationale Separation of waste and reusable items at point of
Contents Glossary of equivalent standards... ix Committee representation... xi Acknowledgments...xiii Background on Amendment 1...xiii Foreword... xiv Introduction: Need for the recommended practice...1
More informationAdvantages. Steam sterilization
Rev. 2 March 2017 Steam sterilization Sterilization is the total destruction of all microorganisms, whether or not pathogenic, and their spores. Moist heat in the form of saturated steam under pressure
More information26/01/2016. A Day in the Life Steam Sterilization Reprocessing. Welcome! House Keeping. From the GoToWebinar page:
SM 3M Health Care Academy A Day in the Life Steam Sterilization Reprocessing January 27, 2016 3M 2016. All Rights Reserved Welcome! Topic: A Day in the Life Steam Sterilization Reprocessing Facilitator:
More informationINSTRUMENT PROCESSING FROM PREP/PACKAGING TO STORAGE. January 2016
INSTRUMENT PROCESSING FROM PREP/PACKAGING TO STORAGE January 2016 Disclosures The opinions expressed in this presentation are those of the author and do not necessarily reflect the official position of
More informationSTERILIZATION SOLUTIONS
INFECTION PREVENTION IMS WRAP SPORECHECK STERILIZATION SOLUTIONS Products and Guidelines for Enhanced Office Safety BAGETTE POUCHES STERILIZATION MONITORING CDC recommends placing an indicator inside each
More informationTHE BASICS OF STERILIZATION
THE BASICS OF STERILIZATION Objectives State the importance of sterilization to patient care Review three key essentials of the sterilization process Describe sterilization methods used, application, limitations,
More informationIn the Know about.appropriate Use of 3M Attest Rapid Readout Biological Indicators
3M Attest Sterile U Web Meeting Jan 22, 2009 In the Know about.appropriate Use of 3M Attest Rapid Readout Biological Indicators ww.3m.com/atteststerileuonline 7/15 Modified per Inma s input. SDF Prepared
More informationRev. 0 October 2017 Terragene offers a range of simple and effective products to precisely control washing and sterilization processes of different instruments in tattoo and body piercing studios. Available
More informationالمملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية
1. POLICY STATEMENT: Sterilization process should be strictly monitored using, physical, chemical and biological indicator and the results of indicators should be supervised by infection control on daily
More informationQUALITY ASSURANCE IN AN MDRD
QUALITY ASSURANCE IN AN MDRD MAINTENANCE AND PREVENTATIVE MAINTENANCE MDRD is a machine dependent department washers, pasteurizers, cart washer, sterilizer, ultrasonic, heat sealers, RO water systems All
More informationSteam Sterilization Monitoring in the New CSA Standard (Z )
Speaker Disclaimer Steam Sterilization Monitoring in the New CSA Standard (Z314.3-14) Rick Bauer, Ph.D. Senior Technical Services Advisor 3M Canada Employed in technical services for 3M Canada Education,
More informationChoose a category. You will be given the answer. You must give the correct question. Click to begin. Instructions for using this template.
Instructions for using this template. Remember this is Jeopardy, so where I have written Answer this is the prompt the players will see, and where I have Question should be the player s response. To enter
More informationNEW Faster, more versatile!
NEW Faster, more versatile! > 35min flexible cycle > Process Single Channel surgical flexible endoscopes > Process Dual Channel surgical flexible endoscopes > Process 10.89 kg of Load including 1 surgical
More informationMedline Gemini Sterilization Wrap. Test Studies
Medline Gemini Sterilization Wrap Test Studies Steam Efficacy : Steam PreVac Steam Efficacy: Steam Gravity Shelf Life: 180 Days Plasma Efficacy: STERRAD 100NX Plasma Efficacy: STERRAD NX Plasma Efficacy:
More informationLow Temperature Processing. An Update on Guidelines, Standards and Requirements
Low Temperature Processing An Update on Guidelines, Standards and Requirements Continuing Education Contact Hours Participants must complete the entire presentation/seminar to achieve successful completion
More informationConsistent. Reliable. Innovative.
Consistent. Reliable. Innovative. Your most trusted partner for sterilization products and services. Monitoring Products for Steam Sterilization NAMSA s Sterilization Products Division manufactures and
More informationPackaging Systems for Central Service Operations
Lesson No. CRCST 132 (Technical Continuing Education - TCE) Sponsored by: by Carol Petro, RN, CRCST, CIS, CNOR OR Educator and Sterile Processing Educator Indiana University Health North Hospital Carmel,
More information2. Describe correct actions to take to address sterilization process failures. 3. List possible causes of sterilization process failures.
Objectives 1. Discuss the importance of sterilization process monitoring. 2. Describe correct actions to take to address sterilization process failures. 3. List possible causes of sterilization process
More informationProducts and Guidelines for Enhanced Office Safety
infection prevention IMS WRAP SporeCheck STERILIZATION solutions Products and Guidelines for Enhanced Office Safety Bagette pouches sterilization monitoring CDC recommends placing an indicator inside each
More informationPART 5. Sterilisation Consumables RFTHPV
PART 5 STATEMENT OF REQUIREMENTS Sterilisation Consumables RFTHPV2015 010 Part 5 Statement of Requirements TABLE OF CONTENTS INTRODUCTION... 3 5.1 Purpose... 3 5.2 Scope... 3 5.3 Product Categories...
More informationNEW Faster, more versatile!
NEW Faster, more versatile! > 35min flexible cycle > Process Single Channel surgical flexible endoscopes > Process Dual Channel surgical flexible endoscopes > Process 10.89 kg of Load Plus 1 surgical flexible
More informationARABIC CANADIAN MEDICAL CENTER CSSD POLICIES AND PROCEDURES
CONTENTS Section Title 2 Disinfection, Packaging and Sterilization 3 Validation of Sterilization (Physical, Chemical and Biological) 4 Sterilizer Requalification 5 Sterile Package Shelf Life 6 Acquisition
More informationNot to be reproduced - AGPAL & QIP
Keep it Clean! Practical methods for implementing correct sterilisation processes advanced level Presented by: Lin Lochead, B. App. Sc Validation A Documented Procedure for obtaining, recording and interpreting
More informationCompetency Guide: Care and Handling of Rigid Endoscopes
Competency Guide: Care and Handling of Rigid Endoscopes This document details the basic steps to correctly process and maintain a rigid endoscope. This document can be used to perform a competency review
More informationCERTIFICATE OF CONFORMANCE Mesa Laboratories, Inc. 625 Zoot Way, Bozeman, MT Phone: (303)
Expiration : Bowie-Dick Test Sheets 77-05-CI-BD110 The ProChem Lead-Free Bowie-Dick Test Sheet is for daily monitoring of pre-vacuum sterilizers operating at 134 C for 3.5 minutes. The test sheet is designed
More informationSYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM
SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM APPLICATION For rapid, safe, standardized low-temperature liquid chemical sterilization of heat-sensitive critical and semi-critical devices. DESCRIPTION
More informationStericool H 2 O 2. plasma sterilizers Affordable low temperature solution
Stericool H 2 plasma sterilizers Affordable low temperature solution Getinge Stericool H 2 plasma sterilizers Meeting everyday demands of the CSSD An affordable low temperature solution Since many components
More informationModel KMF 115 Constant climate chambers with expanded temperature / humidity range
Model KMF 115 Constant climate chambers with expanded temperature / humidity range The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant
More informationUnloading, Storage, Distribution, Transportation and Aseptic Presentation of Sterile Items
Unloading, Storage, Distribution, Transportation and Aseptic Presentation of Sterile Items Comprehensive guide to steam sterilization and sterility assurance in health care facilities (ANSI/AAMI ST79:2006)
More informationSterile Packaging & The End User
Sterile Packaging & The End User HealthPack Conference March 8-10, 2011 Cincinnati, Ohio Presented by: Ray Taurasi MBA, CRCST, CHL, FCS, ACE director clinical sales and services Healthmark Industries Inc.
More informationLow temperature sterilizer Getinge STERIZONE VP4
Low temperature sterilizer Getinge STERIZONE VP4 The new standard of low temperature sterilization This document is intended to provide information to an international audience outside of the US. Innovation
More informationCARE SERVICE USER GUIDE. Sonicision System
CARE SERVICE USER GUIDE Sonicision System TABLE OF CONTENTS Sonicision device product return instructions for post-use cleaning and sterilization...3 How to contact the carrier...5 Frequently asked questions...6
More information8/27/2015. Learning Objectives. Purpose of Sterilization. To destroy all living pathogenic microorganisms
Learning Objectives Compare and contrast the available methods of sterilization for the healthcare setting Describe the appropriate use and monitoring for sterilization methods Purpose of Sterilization
More informationSterilization. Euronda Spa t (+39) m euronda.com
Sterilization The purpose of sterilization is to remove all microbial life forms, including spores and fungi, whether they are pathogenic or not. The sterilization process as a whole has to be in full
More informationVHP M100 Biodecontamination Systems: Open Loop
LOW TEMPERATURE BIODECONTAMINATION* VHP M100 Biodecontamination Systems: Open Loop The proven technology of vaporized hydrogen peroxide biodecontamination for a variety of applications Proven Technology
More informationBiological Indicators and Their Application in Clinical Sterilization Spores Don t Lie 1
Biological Indicators and Their Application in Clinical Sterilization 2010 Spores Don t Lie 1 SGM Biotech, Inc. 10 Evergreen Drive, Suite E Bozeman, MT 59715 Tel: 406-585-9535 Fax: 406-585-9219 email:
More informationMedical Device Reprocessing Quality Assurance. 3M All Rights Reserved.
Medical Device Reprocessing Quality Assurance Additional Content Qualification Testing Flash Sterilization Extended Cycles Recalls Wet Packs Finish 2 Qualification Testing and Required Monitoring Installation
More informationA Sterile Processing User s Guide
Product Manual A Sterile Processing User s Guide Safety, Assurance, Innovation, & Quality enabling perioperative professionals to achieve higher standards of performance and enhanced patient safety Phone:866-ONE-TRAY
More informationYour Sterile Processing Partner. Duraholder IPS
Your Sterile Processing Partner The Bioseal Duraholder Instrument Protection System (IPS) was designed by a leading university hospital to prevent costly damage to their delicate neuro instruments. After
More informationModel FDL 115 Safety drying chambers for limited quantities of solvent
Model FDL 115 Safety drying chambers for limited quantities of solvent The BINDER FDL 115 with silicone and dust-free inner chamber, as well as symmetric airflow dries specimens containing solvents and
More informationE9 Med. The strength of simplicity. Classification:
E9 Med The strength of simplicity Simple, effective and compact, E9 Med is an autoclave that makes Class B sterilization accessible to everyone. Hidden behind its simple, user-friendly interface is an
More informationPartnership. HSG Pre & Post Vacuum - Medium Size Mobile Autoclave. Economic Line
Partnership HSG Pre & Post Vacuum - Medium Size Mobile Autoclave Economic Line Fast,Heavy Duty, for Medical Clinics & OR Economic Line The HSG Economic Line includes 85 liter and 160 liter single door
More informationWhat Dentistry Can Learn from AAMI ST79. Best Practices for device and instrument reprocessing
What Dentistry Can Learn from AAMI ST79 Best Practices for device and instrument reprocessing Learning goals: Purpose and goals of AAMI organization. Overview of ST79. Review selected topics: IFUs, tools
More informationREUSABLE MEDICAL DEVICE VALIDATION
All sterilization processes require validation of the efficacy and reproducibility of the process. Depending on the type of sterilization, this may be accomplished by partial, sub-lethal, or repetitive
More informationENCORE 2G MEDIUM LABORATORY STERILIZER SPECIFICATION/DATA SHEET
ENCORE 2G MEDIUM LABORATORY STERILIZER SPECIFICATION/DATA SHEET The Encore 2G Series Laboratory/Scientific Sterilizer was specifically designed to meet the diversified and budgetary needs of our laboratory
More informationENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing.
11157 ENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing. ETD DOUBLE: INTRODUCING THE FIRST OLYMPUS PASS- THROUGH WASHER-DISINFECTOR With the ETD Double, Olympus Has Advanced Its
More informationTesting of routinely sterilized products should
Product Quality Assurance Testing: One Hospital s Experience Testing of routinely sterilized products should be part of a healthcare facility s quality control program, and ANSI/AAMI ST79:2006, Comprehensive
More informationLets Talk Indicators Challenging the process Sterilization. ICAN 5 th November Peter Newson
Lets Talk Indicators Challenging the process Sterilization ICAN 5 th November Peter Newson Objectives In the context of the Decontamination process what is an indicator? What phases of the process do we
More informationEH&S. Sheet. Fact. Safe and Effective Use of Autoclaves. What are autoclaves? Factors for effective sterilization. Dry heat cycle - when to use
Please post or circulate Fact heet nvironment, ealth and afety Information for the Berkeley Campus No. 33 Revised 04/04/11 afe and ffective Use of Autoclaves Autoclaves are easy to use but can pose a safety
More informationNovember 18, Andersen Sterilizers, Inc. Dr. William Andersen President 3154 Caroline Drive Haw River, North Carolina 27258
DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 November 18, 2015 Andersen
More informationYour Sterile Processing Partner. Duraholder IPS
Your Sterile Processing Partner Table of Contents Item Page Duraholder Case Study 17 AAMI ST79 Reference 20 Steam Sterilization Efficacy Testing 21 PRODUCT INDEX Product Page Standard Pouches DURA050/100
More informationAutoclaves & Sterilizers
Autoclaves & Sterilizers Fax: 714-632-8821 Autoclaves & Sterilizers Autoclave, Sterilizer Unit (Tuttnauer 2340M) Tuttnauer 2340M Manual Autoclave, Sterilizer Manual autoclave is designed to compliment
More information3034 Owen Drive Antioch, TN USA Fax: Maybachstraße 10. Revised 01/17
CLN VersaPak Modular Instrument Tray Symmetry Surgical Inc. 3034 Owen Drive Antioch, TN 37013 USA 1-800-251-3000 Fax: 1-615-964-5566 www.symmetrysurgical.com EC REP Symmetry Surgical GmbH 78532 Tuttlingen,
More informationIdeal Sterilization Method. Sterilization. Sterilization Practices in Healthcare Facilities
Sterilization Practices in Healthcare Facilities Virtual Tour of Central Processing William A. Rutala, Ph.D., M.P.H. Director, Hospital Epidemiology, Occupational Health and Safety Program, UNC Health
More informationMedical Device Reprocessing Assessment - General (Cleaning, Disinfection, and/or Sterilization)
Medical Device Reprocessing Assessment - General (Cleaning, Disinfection, and/or Sterilization) Date: Office Name: Office Number: Responsible Physician: Assessor: M.1. General Yes No N/A If No Please Comment
More informationS.M.A.R.T.Green Test Pack for Prevacuum Sterilizers Technology Overview
Technology Overview S.M.A.R.T.Green Test Pack for Prevacuum Sterilizers Technology Overview Getinge Assure S.M.A.R.T.Green Test Pack is a lead, latex, heavy metal, and toxic metal free Bowie and Dick test
More informationxdental x the sterilization company Domina Plus B Aptica Plus B Atoma Plus
xdental x the sterilization company Domina Plus B Aptica Plus B Atoma Plus THE PREMIUM LINE Dental X Sterilization an important choice The growing concern for the spreading of infection diseases and the
More informationInnovative. Smart. Trusted.
Innovative. Smart. Trusted. We re your partner for sterilization products. Monitoring Products for Vaporized Hydrogen Peroxide Table of Contents Crosstex Industrial is a division of Crosstex International,
More informationThe inaugural use of vaporized
Lesson No. CRCST 164 (Technical Continuing Education - TCE) Sponsored by: Vaporized Hydrogen Peroxide Sterilization BY LARRY TALAPA, BS, MS, CQE - MICROBIOLOGIST AND TECHNICAL SERVICE SPECIALIST, 3M HEALTH
More informationContact: To sterilize or decontaminate uniformly, superheated steam must contact all areas of the load.
Published on UC Davis Safety Services (https://safetyservices.ucdavis.edu) Effective Use of Autoclaves SafetyNet #: 26 Autoclave Use Autoclaves (steam sterilizers) are metal pressure vessels that are used
More informationSecure. Tested. Certified.
Secure. Tested. Certified. We solve problems with confidence and creativity. Monitoring Products for Dry Heat Steam-Formaldehyde FORM Chlorine Dioxide Table of Contents Crosstex Industrial is a division
More informationPart 1: General requirements
Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 11140-1 Third edition 2014-11-01 Sterilization of health care products Chemical indicators Part 1: General requirements Stérilisation des produits
More informationSecure. Tested. Certified.
Secure. Tested. Certified. We solve problems with confidence and creativity. Monitoring Products for Dry Heat DRY Steam-Formaldehyde Chlorine Dioxide FORM CL02 NAMSA s Sterilization Products Division manufactures
More informationEffective Use of Autoclaves
Published on UC Davis Safety Services (https://safetyservices.ucdavis.edu) Effective Use of Autoclaves SafetyNet #: 26 Autoclave Use Autoclaves (steam sterilizers) are metal pressure vessels that are used
More informationAmalgatome SD Sterilization Tray User Guide
Amalgatome SD Sterilization Tray User Guide EXSURCO MEDICAL 10804 GREEN ROAD WAKEMAN, OH 44889 PN: X101489 REV. B This page intentionally left blank. AMALGATOME SD STERILIZATION TRAY USER GUIDE Instructions
More informationSirona competency in hygiene DAC PROFESSIONAL. Hygiene systems. Vacuum autoclave class B to satisfy the most demanding requirements
Sirona competency in hygiene Hygiene systems Vacuum autoclave class B to satisfy the most demanding requirements Professional and fast Sirona s is an autoclave which satisfies the most demanding medical
More information