Sign Planogram: Insulation Roxul Bay Name: Insulation Roxul 3.3

Size: px
Start display at page:

Download "Sign Planogram: Insulation Roxul Bay Name: Insulation Roxul 3.3"

Transcription

1 Article # Article # and recycled ctent D0C-09 Article # 0000 R-value reducing heating and air cditiing recycled ctent Article # D0C-0 Sign Planogram: Insulati Roxul Bay Name: Insulati Roxul. May, 0 of 7 Roxul Safe n Sound Benefits Sound absorbent: helps to create n-combustible: fire-resistant with Better fit: easy to install using a serrated knife Sustainable: made with natural ste Roxul Safe n Sound Thermal Home Insulati R Snug fit between studs: provides maximum N-combustible: provides both thermal Better Fit: easy to install using a serrated knife Sustainable: made with natural ste and Sound absorbent: helps to create n-combustible: fire-resistant with Better fit: easy to install using a serrated knife Sustainable: made with natural ste and recycled ctent D0C-09 Thermal Home Insulati R Snug fit between studs: provides maximum R-value reducing heating and air cditiing N-combustible: provides both thermal Better Fit: easy to install using a serrated knife Sustainable: made with natural ste and recycled ctent D0C-0 Instructis: [Beam signs] Beam signs to be screwed into the beams with () Self-Tapping Screws

2 Sign Planogram: Insulati Roxul Bay Name: Insulati Roxul. May, 0 of 7 x 0 '' Notch= 7 Notch= Notch= x 0 x 8 9 '' x 0 8 '' Notch= 8 Notch= 8 x 0 8 '' in Notch= in in Notch= 0 Item # Part # Descripti Quantity HD Article # Hardware Requirements How to Order D0C-0 Comforbatt Thermal R 0007 () Self-Tapping Screws epop D0C-0 Comforbatt Thermal R () Self-Tapping Screws epop GA00C Self-Tapping Screws (PK/) - - epop Merchandising POG shown is for POP reference ly and is not to be used to set product. Refer to your store specific Merchandise POG for product placement.

3 Effective Date Department: Insulati Roxul 7/7/0 May, 0 Sign Planogram: Insulati Roxul Bay Name: Insulati Roxul. Snug fit between studs: provides maximum Thermal Home Insulati R R-value reducing heating and air cditiing D0C-0 8 Article # 0000 Better Fit: easy to install using a serrated knife Sustainable: made with natural ste and recycled ctent Article # R Insulated Sheathing R recycled ctent Snug fit between studs: provides maximum N-combustible: provides both thermal Better Fit: easy to install using a serrated knife Sustainable: made with natural ste and R-value reducing heating and air cditiing Thermal Home Insulati N-combustible: provides both thermal D0C-0 of 7 Exterior Sheathing Applicati R0 Soluti in the basement: when combined with Roxul ComfortBatt R High recycled ctent: made from natural ste & up to 9% recycled material N-Combustible: provides both thermal Vapor permeable yet water Resistant: allows wall system to breathe Product Dimensis. x x 8 8 sq.ft./pack TM Interior Basement Wall Applicati D009C-0 D009C-0 0x ROX0 Roxul 0x 0// ComfortBoard IS HD Bay Signage (English) St.George Street, Suite 0 C M Y K 0// ROX0_ComfortBoard IS_HD Bay Signage.indd RS Ld ON, Canada Artist /Studio AD / CD AE /AD Proofreader OTHER: NA A t: f: Thermal Insulated Sheathing Interior Basement Applicati As an interior basement wall applicati, ComfortBoard IS is fastened directly to the ccrete wall. The stud wall, wood or metal, is then place directly up against the ComfortBoard IS with no spaces or gaps. ) Ccrete Foundati ) Air/Moisture Barrier* ) Roxul ComfortBoard IS Insulati Sheathing ) x Stud Wall ) Roxul ComfortBatt Batt Insulati ) Vapor Ctrol Layer (where required) How To Install ComfortBoard IS in Just Easy Steps Install air/moisture barrier where required and then mechanically fasten or adhere ComfortBoard IS to the ccrete wall. Install wall studs directly against ComfortBoard IS, leaving no gaps or air space. Install. ComfortBatt R batt insulati between studs to create an R0 wall. Install vapor barrier.* Apply drywall panels horiztally or vertically to framing. *best practice, check with local jurisdicti for building code requirements. Thermal Insulated Sheathing Interior Basement Applicati As an interior basement wall applicati, ComfortBoard IS is fastened directly to the ccrete wall. The stud wall, wood or metal, is then place directly up against the ComfortBoard IS with no spaces or gaps. 8 from floor to top of tear pad ) Ccrete Foundati ) Air/Moisture Barrier* ) Roxul ComfortBoard IS Insulati Sheathing ) x Stud Wall ) Roxul ComfortBatt Batt Insulati ) Vapor Ctrol Layer (where required) How To Install ComfortBoard IS in Just Easy Steps Install air/moisture barrier where required and then mechanically fasten or adhere ComfortBoard IS to the ccrete wall. Install wall studs directly against ComfortBoard IS, leaving no gaps or air space. Install. ComfortBatt R batt insulati between studs to create an R0 wall. Install vapor barrier.* Apply drywall panels horiztally or vertically to framing. *best practice, check with local jurisdicti for building code requirements. Snug fit between studs: provides maximum R-value reducing heating and air cditiing Thermal Home Insulati R Better Fit: easy to install using a serrated knife Sustainable: made with natural ste and recycled ctent D0C-0 8 Article # 0000 pot Use Only. Do Not Copy or Distribute. MERCHANDISER Article # Stephen Mcveigh R Insulated Sheathing Exterior Sheathing Applicati Interior Basement Wall Applicati R0 Soluti in the basement: when combined with Roxul ComfortBatt R High recycled ctent: made from natural ste & up to 9% recycled material N-Combustible: provides both thermal Vapor permeable yet water Resistant: allows wall system to breathe Product Dimensis. x x 8 8 sq.ft./pack TM D009C-0 D009C-0 0x ROX0 Roxul 0x 0// ComfortBoard IS HD Bay Signage (English) St.George Street, Suite 0 C M Y K 0// ROX0_ComfortBoard IS_HD Bay Signage.indd RS Ld ON, Canada Artist /Studio AD / CD AE /AD Proofreader OTHER: NA A t: f: D0C-0 recycled ctent Snug fit between studs: provides maximum N-combustible: provides both thermal Better Fit: easy to install using a serrated knife Sustainable: made with natural ste and R-value reducing heating and air cditiing Thermal Home Insulati N-combustible: provides both thermal R Instructis: [Beam signs] Beam signs to be screwed into the beams with () Self-Tapping Screws [Tear Pad] Attach Tear Pad to upright using zip ties so top edge is 8 above the floor [Beam Labels] Remove old beam labels (if applicable) and place new label the beam below the product Stephen_Mcveigh@Homedepot

4 Sign Planogram: Insulati Roxul Bay Name: Insulati Roxul. May, 0 of 7 x 0 '' Notch= tch= 8 Notch= Notch= x 0 x 8 9 '' x 0 8 '' Notch= 8 x 0 8 '' in Notch= in 9 in Notch= 0 Item # Part # Descripti Quantity HD Article # Hardware Requirements How to Order D0C-0 Comforbatt Thermal R 0009 () Self-Tapping Screws epop D0C-0 Comforbatt Thermal R () Self-Tapping Screws epop ROX0 Roxul ComfortBoard Tear Pad - Zip Ties epop D009C-0 Roxul R Insulated Sheathing - - epop GA00C Zip Ties - - epop GA00C Self-Tapping Screws (PK/) - - epop Merchandising POG shown is for POP reference ly and is not to be used to set product. Refer to your store specific Merchandise POG for product placement.

5 Article # 0009 diywithroxul.com Better Renos Made Easy with Roxul Insulati. Get the resources you need to get the job de smarter and faster with the Roxul DIY Video Series. Article # 0009 and recycled ctent D0C-07 Article # and recycled ctent Article # D0C-09 Sign Planogram: Insulati Roxul Bay Name: Insulati Roxul. May, 0 of Sound absorbent: helps to create n-combustible: fire-resistant with Better fit: easy to install using a serrated knife Sustainable: made with natural ste Sound absorbent: helps to create n-combustible: fire-resistant with Better fit: easy to install using a serrated knife Sustainable: made with natural ste 9 8 from floor to top of brochure 9 Better Renos Made Easy with Roxul Insulati. Get the resources you need to get the job de smarter and faster with the Roxul DIY Video Series. diywithroxul.com 7 8 Sound absorbent: helps to create n-combustible: fire-resistant with Better fit: easy to install using a serrated knife Sustainable: made with natural ste and recycled ctent Sound absorbent: helps to create n-combustible: fire-resistant with Better fit: easy to install using a serrated knife Sustainable: made with natural ste and recycled ctent D0C D0C-09 Instructis: [Beam signs] Beam signs to be screwed into the beams with () Self-Tapping Screws [Brochures] Insert brochure into trifold brochure holder, attached to upright, so that top edge is 8 above the floor

6 Sign Planogram: Insulati Roxul Bay Name: Insulati Roxul. May, 0 of 7 x 0 '' Notch= Notch= Notch= x 0 x 8 9 '' 7 8 x 0 8 '' Notch= 8 tch= 8 x 0 8 '' in 9 Notch= 8 in 9 in Notch= 0 Item # Part # Descripti Quantity HD Article # Hardware Requirements How to Order 7 D0C-07 Safe N Sound Wood Studs 0009 () Self-Tapping Screws epop 8 D0C-09 Safe N Sound Wood Studs () Self-Tapping Screws epop 9 ROX-_ Roxul DIY Brochure - Brochure Holder epop GA00C Brochure Holder - - epop GA00C Self-Tapping Screws (PK/) - - epop Merchandising POG shown is for POP reference ly and is not to be used to set product. Refer to your store specific Merchandise POG for product placement.

7 Article # 0000 Article # 0009 Article # Article # to Achieve R0 Sign Planogram: Insulati Roxul Bay Name: Insulati Roxul May, 0 7 of 7 Additial POP available epop: 0 Thermal Home Insulati For x exterior walls and attics R FoR x WooD STuDS Snug fit between studs: provides maximum R-value reducing heating and air cditiing N-combustible: provides both thermal Better Fit: easy to install using a serrated knife Sustainable: made with natural ste and recycled ctent Loose Fill Attic Insulati Top Up With ROxUL ROCkFILL ROxUL ROCkFILL Benefits N combustible: fire resistant to temperatures up to 77ºc No Blowing Machine required: install at your own pace dense Ste Wool: insulati w t move or settle over time Installs in easy steps: open, aerate, spread Installing ROCkFILL is as easy as --. Open. Aerate. Spread NO BLOWINg MAChINe ReqUIRed D0C-0 One bag of ROckFill covers approximately. square feet to a depth of. inches (R). D0C-0 STeel STudS Sound absorbent: helps to create n-combustible: fire-resistant with Better fit: easy to install using a serrated knife Sustainable: made with natural ste and recycled ctent STeel STudS Sound absorbent: helps to create n-combustible: fire-resistant with Better fit: easy to install using a serrated knife Sustainable: made with natural ste and recycled ctent. 7 D0C D0C-0 Item # Part # Descripti Quantity HD Article # Hardware Requirements How to Order 0 D0C-0 Comfortbatt Thermal R 0000 () Self-Tapping Screws epop D0C-0 RockFill Loose Fill Attic () Self-Tapping Screws epop D0C-08 Safe N Sound Steel Studs 0009 () Self-Tapping Screws epop D0C-0 Safe N Sound Steel Studs () Self-Tapping Screws epop

BUILDING INSULATION. Residential Product Guide

BUILDING INSULATION. Residential Product Guide BUILDING INSULATION Residential Product Guide A global leader ROCKWOOL is part of ROCKWOOL International, the world s largest producer of stone wool insulation a material that improves the quality of life

More information

ROXUL Insulation Quest Work Plan

ROXUL Insulation Quest Work Plan ROXUL Insulation Quest Work Plan 1 ROXUL Insulation Work Plan Features & Benefits Product Offering Special Order Program Sales Call Planner Merchandising Checklist Training Procedure Relationship Building

More information

THERMAL BATT INSULATION COMFORTBATT. Thermal Batt Insulation for Residential & Commercial Construction.

THERMAL BATT INSULATION COMFORTBATT. Thermal Batt Insulation for Residential & Commercial Construction. THERMAL BATT INSULATION COMFORTBATT Thermal Batt Insulation for Residential & Commercial Construction. Superior building envelope performance by ROCKWOOL Insulation. ROCKWOOL COMFORTBATT is a semi-rigid

More information

Mid-Rise Wood Construction Solutions Guide

Mid-Rise Wood Construction Solutions Guide Mid-Rise Wood Construction Solutions Guide Introduction The Mid-Rise Wood Construction Solutions Guide identifies several common locations where ROCKWOOL TM insulation can be used effectively in mid-rise

More information

PROTOTYPICAL Sign Planogram: Enviro Tile Bay Name: Enviro Tile 3.1

PROTOTYPICAL Sign Planogram: Enviro Tile Bay Name: Enviro Tile 3.1 HD8000_00E_0x_Banner_.pdf 06--0 :7 PM ' ' ' 6' 7' 8' 9' 0' ' ' ' ' ' ' 8 6 8 0 8 0 0 6 8 6 6 8 0 0 6 0 6 ' 6 9 8 8 6 7 7 7 8 0 9 0 9 ' 8 0 6 8 6 8 0 6 76 76 8 90 0 0 6 8 0 0 6' 8 0 6 8 6 8 0 6 76 76 8

More information

Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond

Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond Batt Fiberglass Mineral Wool Cotton Wool Blown, Sprayed Fiberglass Spray Foam Cellulose Wool Board Polystyrene (XPS, EPS) Polyisocyanurate

More information

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation Johns Manville MinWool Water & Fire Block Mineral Wool Insulation Johns Manville s MinWool Water & Fire Block mineral wool insulation provides a vapor-permeable continuous layer of insulation. Along with

More information

RainBarrier Installation Guide

RainBarrier Installation Guide Installation Guide Installation Instructions for: > / Impasse Hanger Attachment > / Attachment > Brick Tie/Masonry Anchor Installation > Installation within -Type Framing > Installation Installation Guide

More information

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation Division: 07 00 00 Thermal and Moisture Protection Section: 07 21 00 Thermal Insulation Report Holder: Icynene Inc. 6747 Campobello Rd. Mississauga, Ontario L5N 2L7 CANADA (905)363-4040 www.icynene.com

More information

Thermal Characteristics of Exterior Building Wall (Above Heritage Building

Thermal Characteristics of Exterior Building Wall (Above Heritage Building Minimum Required R Value for Wall (Above Ground) RSI 2.78 (R 15.8) Thermal Characteristics of Exterior Building Wall (Above Ground) @ Heritage Building W1 W2 Exterior Wall - Stucco Cladding @ 1st Floor

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC. 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3500 Reissued 01/2016 This report is subject to renewal 01/2017. DIVISION: 07 00 00 THERMAL

More information

9.36. Energy Efficiency

9.36. Energy Efficiency Resources and Information NRCAN Energy Efficiency http://www.nrcan.gc.ca/energy/efficiency Canadian Wood Council Wall Thermal Design Tool http://cwc.ca/resources/wall-thermal-design/ 9.36. Energy Efficiency

More information

Insulation Fastener Guide IKO Ener-Air & IKO Enerfoil Wall Insulation

Insulation Fastener Guide IKO Ener-Air & IKO Enerfoil Wall Insulation Insulation Fastener Guide IKO Ener-Air & IKO Enerfoil Design Considerations The type and frequency of a fastener system is typically decided by a structural engineer or in collaboration with a design professional.

More information

INSULATION INSTALLATION

INSULATION INSTALLATION City of Bullhead City Development Services/Public Works Residential Permit Submittal Requirements INSULATION INSTALLATION Contact Information: Building Division (928) 763-0124 Planning & Zoning Division

More information

ROXUL SAFE Applications Guide

ROXUL SAFE Applications Guide FIRE-FIRST APPLICATIONS ROXUL SAFE Applications Guide TM Fire blocks, firestops, and rated assemblies 3 Introduction 4 ROCKWOOL Solutions for Fire Separation and Firestopping 6 Project The Ritz-Carlton

More information

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

SECTION THERMAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION THERMAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 072100 - THERMAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. A Subsidiary of the International Code Council

More information

TYPICAL BEARING WALL FRAMING

TYPICAL BEARING WALL FRAMING BASIC WOOD FRAMING City of Grand Rapids Building Safety Division 218-326-7601 www.grandrapidsmn.org This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code,

More information

EPA Seal and Insulate with ENERGY STAR Insulation Product Certification Report: ROXUL Inc. COMFORTBATT Insulation

EPA Seal and Insulate with ENERGY STAR Insulation Product Certification Report: ROXUL Inc. COMFORTBATT Insulation UL LLC 333 Pfingsten Road Northbrook, IL 60062 2014-04-25 U.S. Environmental Protection Agency (EPA) Seal and Insulate with ENERGY STAR Insulation Product Certification Report - COMFORTBATT Insulation

More information

CANADA COMMERCIAL + RESIDENTIAL Building Insulation Guide

CANADA COMMERCIAL + RESIDENTIAL Building Insulation Guide CANADA COMMERCIAL + RESIDENTIAL Building Insulation Guide TABLE OF CONTENTS Here at Johns Manville, we are more than your supplier; we are your channel partner. When you do business with JM, you can count

More information

AUGUST AUSTRALITE fire, acoustics & thermal technical manual

AUGUST AUSTRALITE fire, acoustics & thermal technical manual AUGUST 07 AUSTRALITE fire, acoustics & thermal technical manual AUSTRALITE CONTENTS Fire Resistance Levels / How to Use Structural Adequacy Charts / N-Loadbearing Structural Adequacy FRL s / 6 Loadbearing

More information

Chapter 14 - Air Sealing

Chapter 14 - Air Sealing Chapter 14 - Air Sealing Contents Chapter 14 - Air Sealing... 14-1 Pre-Mechanicals Activities... 14-3 Insulate Bathtub Enclosures... 14-3 Insulate Double Walls and Chases... 14-3 Pre-Inspection Checklist...

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3210 Valid: 03/15 to 03/16 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21

More information

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507) Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN 55046 (507) 744-2327 fax (507) 744-5554 2006 RESIDENTIAL CONSTRUCTION CHECKLIST The following checklist has been designed

More information

Gold Bond BRAND Kal-Kore Plaster Base

Gold Bond BRAND Kal-Kore Plaster Base BRAND 09 29 22 00/NGC 39/NGC Kal-Kore Plaster Base brand Kal-Kore Plaster Base is a tapered-edge gypsum plaster base with 100-percent recycled gray absorptive face paper surface designed to permit rapid

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4073 Issued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ]. National Master Specification (NMS) Section 07 21 16 BLANKET INSULATION Publisher: Spex.ca Page 1 Approved: 2014-12-31 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section [ ]. 1.2 REFERENCES.1 CSA Group.1

More information

Thermal/Acoustical Insulation. Data Sheet BI-RL-DS 05-18

Thermal/Acoustical Insulation. Data Sheet BI-RL-DS 05-18 Thermal/Acoustical Insulation Data Sheet BI-RL-DS 05-18 Think of it as green... only browner. ECOROLL INSULATION with ECOSE Technology All Knauf Insulation products are sustainable. EcoRoll fiberglass

More information

Wall Enclosure Monitoring and Performance Assessment for the Orchards at Orenco Passive House

Wall Enclosure Monitoring and Performance Assessment for the Orchards at Orenco Passive House Wall Enclosure Monitoring and Performance Assessment for the Orchards at Orenco Passive House PORTLAND BEC / WALSH CONSTRUCTION CO / ROXUL APRIL 3, 2017 JONATHAN SMEGAL, SENIOR PROJECT MANAGER, RDH BUILDING

More information

ICC-ES Evaluation Report Reissued February 1, 2011 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Reissued February 1, 2011 This report is subject to re-examination in one year. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1826 Reissued February 1, 2011 This report is subject to re-examination in one year. A Subsidiary of the International Code Council

More information

Foil Back Gypsum Board

Foil Back Gypsum Board BRAND 09 29 00/NGC Foil Back Gypsum Board brand Foil Back Gypsum Board consists of a fire-resistant gypsum core with a heavy, natural finish and 100-percent recycled paper on the face and a strong liner

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2670 Reissued 07/2017 This report is subject to renewal 07/2019. DIVISION: 07 00

More information

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 2-17

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 2-17 Thermal/Acoustical Insulation Data Sheet BI-BT-DS 2-17 Think of it as green...only browner. Knauf Insulation EcoBatt Insulation with ECOSE Technology All Knauf Insulation products are sustainable. EcoBatt

More information

ICC-ES Evaluation Report Reissued February 1, 2012 This report is subject to renewal February 1, 2013.

ICC-ES Evaluation Report Reissued February 1, 2012 This report is subject to renewal February 1, 2013. * ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1826* Reissued February 1, 2012 This report is subject to renewal February 1, 2013. A Subsidiary of the International Code Council

More information

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015. * ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015. A Subsidiary of the International Code Council

More information

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 08-17

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 08-17 Thermal/Acoustical Insulation Data Sheet BI-BT-DS 08-17 Think of it as green... only browner. ECOBATT INSULATION with ECOSE Technology All Knauf Insulation products are sustainable. EcoBatt glass mineral

More information

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION a a FIBER GLASS INSULATION ComfortTherm Batts and Rolls EasyFit Perforated Batts Unfaced Batts and Rolls Kraft-Faced Batts and Rolls JM Climate Pro /JM Attic Protector Blow-in Insulation JM Spider Blow-in

More information

Issue Date: April 2003 Release: I. Product Specifications

Issue Date: April 2003 Release: I. Product Specifications Issue Date: April 2003 Release: I Product Specifications Forming System Components Standard System Commercial System Issue Date: April 2003 Release: I 1.1 Issue Date: April 2003 Release: I 1.2 Specification

More information

Insulated Cold-Formed Steel Wall Panels: A case study of a contractor-manufacturer

Insulated Cold-Formed Steel Wall Panels: A case study of a contractor-manufacturer Insulated Cold-Formed Steel Wall Panels: A case study of a contractor-manufacturer Submitted to: Partnership for Advancing Technology in Housing U.S. Department of Housing and Urban Development Washington,

More information

Fastener Guidelines. Issued: 2015 Technical Communication - Fastener Guidelines DESIGN BASIS

Fastener Guidelines. Issued: 2015 Technical Communication - Fastener Guidelines DESIGN BASIS Issued: 2015 Re: Technical Communication - Fastener Guidelines DESIGN BASIS 1. MECHANICAL ATTACHMENT For permanent attachment, ROCKWOOL stone wool (mineral wool) insulation should be mechanically attached

More information

PROTOTYPICAL Sign Planogram: DW Compound & Tape Bay Name: DW Compound 7.7

PROTOTYPICAL Sign Planogram: DW Compound & Tape Bay Name: DW Compound 7.7 Product Composition EZ-Grid Technology No Abrasive Aggregate or Filler UL Greenguard Gold Certified* Glass-Fiber Free Cuts Clean Cuts Easily with Hand Tool Less Dust and Debris Exceptional Workability

More information

Construction Standards PAGE

Construction Standards PAGE Construction Standards PAGE 072100-1 SECTION 072100 PART 1 - GENERAL 1.1 M.S.U. ISSUES A. It the intent of MSU that insulation of its projects will comply with LEED NC 3 Credit Requirements EA Prerequisite

More information

PROTOTYPICAL Planogram: StorgeBuild + DeckBoxes Bay Name: StorgeBuild + DeckBoxes 4.4

PROTOTYPICAL Planogram: StorgeBuild + DeckBoxes Bay Name: StorgeBuild + DeckBoxes 4.4 Bay Name: StorgeBuild + DeckBoxes 4.4 1 of 10 1 1 72" from floor to bottom of AV Photo is for reference of POP placement only. Refer to your store specific POG for actual layout. Instructions: [Aisle Violators]

More information

Quality Insulation Installation (QII) Insulation Installation (Page 1 of 4)

Quality Insulation Installation (QII) Insulation Installation (Page 1 of 4) Quality Insulation Installation (QII) Insulation Installation (Page 1 of 4) A. QUALITY (QII) PREPARATION FOR INSULATION 01 Air barrier installation and preparation for insulation was done and verified

More information

SECTION THERMAL INSULATION

SECTION THERMAL INSULATION PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 21 13 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

CANADA COMMERCIAL + RESIDENTIAL Building Insulation Guide

CANADA COMMERCIAL + RESIDENTIAL Building Insulation Guide CANADA COMMERCIAL + RESIDENTIAL Building Insulation Guide TABLE OF CONTENTS Here at Johns Manville, we are more than your supplier; we are your channel partner. When you do business with JM, you can count

More information

RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE. Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD 80

RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE. Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD 80 RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD 80 Contents Introduction How to Use this Guide...1 Split-Insulation Wall Assembly...2

More information

INSULATION BATT (1) (2) Code Reference: 2016 Title 24, Reference Appendices RA3.5. Pressure or Friction Fit

INSULATION BATT (1) (2) Code Reference: 2016 Title 24, Reference Appendices RA3.5. Pressure or Friction Fit R-H-DI1 Envelope INSULATION BATT Pressure or Friction Fit Insulation should be cut to fit snugly against studs on all sides, and should completely fill the cavity with no air gaps. Cut lengths of insulation

More information

PROJECT DIRECTIVE # FOR KALISPELL PUBLIC SCHOOLS

PROJECT DIRECTIVE # FOR KALISPELL PUBLIC SCHOOLS PROJECT DIRECTIVE #1 2010-11 FOR KALISPELL PUBLIC SCHOOLS GLACIER HIGH SCHOOL SITE INVESTIGATION SECOND FLOOR CLASSROOM PODS INSULATION AND VAPOR BARRIER INSPECTION TECHNICAL MEMORANDUM NO. 1.1 April 1,

More information

INSTALLATION GUIDE EPS FOAM

INSTALLATION GUIDE EPS FOAM INSTALLATION GUIDE EPS FOAM EPS Foam: Multipurpose rigid foam boards can be used for a variety of applications including insulation in walls, roofs, and foundations, for retrofits or new construction.

More information

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California Reissued June 1, 2002 ICBO Evaluation Service, Inc. 5360 Workman Mill Road, Whittier, California 90601 www.icboes.org Filing Category: DESIGN Concrete DURISOL WALL FORMS FOR CONCRETE CONSTRUCTION DURISOL

More information

NEWS LETTER MARCH 27, 2009

NEWS LETTER MARCH 27, 2009 PLANNING, BUILDING & DEVELOPMENT SERVICES DEPARTMENT 580-1 Street S.E. Medicine Hat, Alberta T1A 8E6 Telephone: 529-8374 FAX 502-8038 1 NEWS LETTER MARCH 27, 2009 GENERAL As you are probably aware there

More information

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min.

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min. FRAMING TIPS City of Grand Rapids Building Safety Division 218-326-7601 www.grandrapidsmn.org This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code, Grand

More information

Knauf Data Sheet BI-DS Thermal/Acoustical Insulation

Knauf Data Sheet BI-DS Thermal/Acoustical Insulation Knauf Data Sheet BI-DS-7 9-09 Thermal/Acoustical Insulation Knauf EcoBatt Think of it as green...only browner. Insulation with ECOSE Technology... All Knauf products are sustainable. EcoBatt Glasswool

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES 1.0 INTRODUCTION INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR COMPOSITE STEEL SHEET AND NONCOMBUSTIBLE SHEATHING PANELS EC 012-2016

More information

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 08-17

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 08-17 Thermal/Acoustical Insulation Data Sheet BI-BT-DS 08-17 Think of it as green... only browner. ECOBATT INSULATION with ECOSE Technology All Knauf Insulation products are sustainable. EcoBatt glass mineral

More information

D25- Utility Hooks PM Callouts

D25- Utility Hooks PM Callouts D25- Utility Hooks PM Callouts EXECUTION The project is called Utility Hooks (commonly referred to as garage /home organization ) with one of 4 scenarios at execution: Scenario 1: ½ MEGA wall OR ½ peg

More information

Chapter 4: Insulation

Chapter 4: Insulation Chapter 4: Insulation Insulation levels expressed in R-values are determined by the compliance path as explained in Chapter 1, Compliance. For below-grade walls and slab-on-grade insulation details see

More information

Thermal/Acoustical Insulation. Knauf Data Sheet BI-BT-DS 08-13

Thermal/Acoustical Insulation. Knauf Data Sheet BI-BT-DS 08-13 Thermal/Acoustical Insulation Knauf Data Sheet BI-BT-DS 08-13 Think of it as green...only browner. Knauf EcoBatt Insulation with ECOSE Technology All Knauf products are sustainable. EcoBatt Glasswool Insulation

More information

Chapter 12. Air Sealing and Insulation

Chapter 12. Air Sealing and Insulation Chapter 12. Air Sealing and Insulation 12.1 BUILDING SCIENCE FACTS 12.2 PREPARATION 12.3 AIR SEALING 12.4 INSTALLING INSULATION IN WALL CAVITIES 12.5 INSTALLING POLY VAPOR BARRIER Tools needed by volunteers:

More information

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3089 Reissued 07/2016 This report is subject to renewal 07/2018. DIVISION: 07 00

More information

Structural and Hygrothermal Field Monitoring of Thick Continuously Insulated Wall Assemblies Utilized in a Multi-Story Residential Building

Structural and Hygrothermal Field Monitoring of Thick Continuously Insulated Wall Assemblies Utilized in a Multi-Story Residential Building Structural and Hygrothermal Field Monitoring of Thick Continuously Insulated Wall Assemblies Utilized in a Multi-Story Residential Building Gary Parsons The Dow Chemical Company Jeff Hansbro -The Dow Chemical

More information

APPLICATION FOR FINISHED BASEMENT PERMIT

APPLICATION FOR FINISHED BASEMENT PERMIT APPLICATION FOR FINISHED BASEMENT PERMIT REAL ESTATE TAX I.D. #: - - _ - _ 7607 W College Drive Ph: (708) 361-1804 Fax: (708) 923-7112 building@palosheights.org APPLICANTS: COMPLETE ALL ITEMS AND SUBMIT

More information

Our sophisticated knowledge base and innovative product line promote quality green building methods, energy efficiency, comfort and health.

Our sophisticated knowledge base and innovative product line promote quality green building methods, energy efficiency, comfort and health. We provide specialized building supplies, expert guidance, and advanced education to architects, contractors, building owners, and construction industry professionals. Our sophisticated knowledge base

More information

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System -Hour Wall System The -hour Wall System is a -hour fire wall consisting of two layers of in. (. mm) shaftliner panels friction-fit between in. (0. mm) light-gauge steel H-Studs and a layer of /" Fire-Shield

More information

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction Walls And Ceilings Single- And Double-Layer Construction 09 9 00/NGC Single-Layer Construction The single-layer construction system consists of a single layer of Gold Bond brand Gypsum Board applied to

More information

BUILDING CODE REQUIREMENTS

BUILDING CODE REQUIREMENTS Wood-frame walls and floors offer designers a unique opportunity to provide structures with economy as well as proven energy performance. Where these assemblies are required by the building codes to achieve

More information

Cladding Attachment and Support

Cladding Attachment and Support Cladding Attachment and Support All types of cladding can be used with ROCKWOOL COMFORTBOARD in the split-insulation wall assembly. The strategy to attach the cladding will depend on the weight and support

More information

Fire-resistant Sound absorbent High density for sag-free, tight fits Green features for sustainable development

Fire-resistant Sound absorbent High density for sag-free, tight fits Green features for sustainable development Fire-resistant Sound absorbent High density for sag-free, tight fits Green features for sustainable development Batt insulation that fights both fire and noise Roxul s AFB is a lightweight, semi-rigid

More information

EcoTouch Insulation with PureFiber Technology

EcoTouch Insulation with PureFiber Technology PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC. 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3500 Reissued 01/2017 This report is subject to renewal 01/2018. DIVISION: 07 00

More information

FIREBLOCK/DRAFTSTOPPING INFORMATION CODE INFORMATION FOR 1 & 2-FAMILY DWELLINGS FOR WOOD-FRAMED CONSTRUCTION FIREBLOCK

FIREBLOCK/DRAFTSTOPPING INFORMATION CODE INFORMATION FOR 1 & 2-FAMILY DWELLINGS FOR WOOD-FRAMED CONSTRUCTION FIREBLOCK Building Safety Department 400-2 nd Street South St. Cloud, MN 56301 (320) 255-7239 FIREBLOCK/DRAFTSTOPPING INFORMATION CODE INFORMATION FOR 1 & 2-FAMILY DWELLINGS FOR WOOD-FRAMED CONSTRUCTION FIREBLOCK

More information

STUDIO DESIGN GUIDE. backyard escape studios made in ontario. Modern. Accessory Buildings BEAUTIFUL, CUSTOMIZED MODERN SHED SPACES FOR ALL YEAR USE.

STUDIO DESIGN GUIDE. backyard escape studios made in ontario. Modern. Accessory Buildings BEAUTIFUL, CUSTOMIZED MODERN SHED SPACES FOR ALL YEAR USE. STUDIO DESIGN GUIDE backyard escape studios made in ontario Modern Accessory Buildings BEAUTIFUL, CUSTOMIZED MODERN SHED SPACES FOR ALL YEAR USE. Kellner Innovations Inc. 1812 Ennismore Crescent London,

More information

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE The sections and construction details in Details 502.2.1.5(1), 502.2.1.5(2), 502.2.1.5(3), 502.2.1.5(4) and 502.2.1.5(5), and Tables 502.2.3.1(1), 502.2.3.1(2), 502.2.3.1(3), 502.2.3.2, 502.2.3.3, 502.2.3.5

More information

A Rater s perspective from the field. Thomas H. Marston, February 21, 2007

A Rater s perspective from the field. Thomas H. Marston, February 21, 2007 A Rater s perspective from the field Thomas H. Marston, February 21, 2007 The checklist looks at the thermal envelope - the place where air sealing and insulation meet. Each of the items addresses a potential

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC. 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1172 Reissued 02/2017 This report is subject to renewal 02/2018. DIVISION: 07 00

More information

SKAMOTEC 225 INSTALLERS GUIDE For 1-1/2 Thickness

SKAMOTEC 225 INSTALLERS GUIDE For 1-1/2 Thickness SKAMOTEC 225 INSTALLERS GUIDE For 1-1/2 Thickness SKAMOTEC 225 Full Length Installation Video For more information contact: Toll free 1-(844)-475-2665 www.skamotec225.com skamotec225@skamol.com Revised:

More information

SUBMITTAL FORM All GreenFiber Products Date: Submitted to: Submitted by: Job Reference: Job Name: GREENFIBER PRODUCT ATTRIBUTES

SUBMITTAL FORM All GreenFiber Products Date: Submitted to: Submitted by: Job Reference: Job Name: GREENFIBER PRODUCT ATTRIBUTES SUBMITTAL FORM All GreenFiber s Date: MADE WITH 85% RECYCLED PAPER FIBER Submitted to: Submitted by: Job Reference: Job Name: GREENFIBER PRODUCT ATTRIBUTES Fire Safety All GreenFiber s meet CPSC Flame

More information

Top plates. Stud. Pre cut stud. 8 ft, 1 1/8 inch. 4 inch brick veneer ½ inch plywood sheathing. Insulation placed between the studs

Top plates. Stud. Pre cut stud. 8 ft, 1 1/8 inch. 4 inch brick veneer ½ inch plywood sheathing. Insulation placed between the studs This example problem will illustrate the calculation of thermal resistance of a wall, calculation of heat flow through the wall, and how to obtain the temperature gradient through the wall. The elevation

More information

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only Installation Method (Existing Walls) 1. ESP Low-E Housewrap is installed over exterior wall sheathing, make sure reflective side faces out: foil flange faces down. 2. Determine width of ESP Low-E HouseWrap

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4195 Issued 12/2017 This report is subject to renewal 06/2018. DIVISION: 07 00 00

More information

Originally Issued: 2/12/2016 Revised: 07/28/2017 Valid Through: 2/28/2018

Originally Issued: 2/12/2016 Revised: 07/28/2017 Valid Through: 2/28/2018 EVALUATION SUBJECT: FOAMSULATE 50 AND FOAMSULATE 210 SPRAY-APPLIED POLYURETHANE FOAM PLASTIC INSULATION REPORT HOLDER: Accella Polyurethane Systems 100 Enterprise Drive Cartersville, GA 30120 (770) 607-0755

More information

Presented by: Stephen Carr Regional Building Science Manager (386)

Presented by: Stephen Carr Regional Building Science Manager (386) Presented by: Stephen Carr Regional Building Science Manager (386) 846-9155 stephen.carr@topbuild.com Understanding the Energy Code 2015 IECC CZ 1 CZ 2 CZ 3 CZ 4 CZ 5 CZ 6 CZ 7&8 Ceiling 30 38 38 49 49

More information

Thermal Bridging From Cladding Attachment Strategies Through Exterior Insulation

Thermal Bridging From Cladding Attachment Strategies Through Exterior Insulation Thermal Bridging From Cladding Attachment Strategies Through Exterior Insulation PHIUS 9 TH ANNUAL NAPHC, SAN FRANCISCO BAY AREA COLIN SHANE M.ENG, P.ENG 12 SEPTEMBER 2014 Learning Objectives / Overview

More information

Charter Township of Washington

Charter Township of Washington Charter Township of Washington Building Department 57900 V an Dyke Washington, MI. 48094 Phone:(586) 786-0010 Ext. 211 Fax: 586-752-6463 2015 Michigan Residential Code Energy Worksheet for New Single-family

More information

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System 0 00/NGC NATIONAL GYPSUM COMPANY -Hour Wall System The -Hour is a -hour fire wall consisting of in. (0. mm) light-gauge steel H-Studs that secure two layers of in. (. mm) shaftliner panels friction-fit

More information

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION: OWENS CORNING PRODUCTS What exactly is an insulating system? The answer starts with the role insulation plays in your home. All insulating products are based on a single basic principle: heat moves from

More information

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. A Subsidiary of the International Code Council

More information

Table Air Barrier and Insulation Inspection Component Criteria

Table Air Barrier and Insulation Inspection Component Criteria Table 40.4. Air Barrier and Insulation Inspection Component Criteria NUMBER COMPONENT CRITERIA Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial

More information

INSTALLERS GUIDE For 1-1/2 Thickness

INSTALLERS GUIDE For 1-1/2 Thickness SKAMOTEC 225 INSTALLERS GUIDE For 1-1/2 Thickness SKAMOTEC 225 Full Length Installation Video For more information contact: NEUEX HEARTH PRODUCTS 1-980-236-7478 skamotec@neuex.com Revised: July 27, 2018

More information

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage

More information

Attachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing

Attachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing Attachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing Installation Instructions Revised 10/25/2016 Scope For the 2015 IBC (cold-formed Steel) and IRC see ABTG Report No. 1503-02

More information

Chapter 13. Ceiling Sheetrock

Chapter 13. Ceiling Sheetrock Chapter 13. Ceiling Sheetrock 13.1 PREPARATION 13.2 PLANNING 13.3 GENERAL INSTALLATION RULES 13.4 INSTALLING CEILING SHEETROCK 13.5 ASSEMBLING SCUTTLE BOX COVER 13.6 FINISHING SCUTTLE BOX COVER Tools needed

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3883 Reissued 08/2017 This report is subject to renewal 04/2018. DIVISION: 07 00

More information

Installation Guide Wall Panels

Installation Guide Wall Panels Installation Guide Wall Panels Jointless or Dry-Stacked Installation (Read Prior to installation) The MStone system is a jointless / dry-stacked installation where panels and corners fit tightly together

More information

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building 2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building Building Department 52700 Van Dyke, Shelby Township, MI 48316 Phone (586) 731-5969 Fax (586) 803-2099 building@shelbytwp.org

More information

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building 2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building Building Department 52700 Van Dyke, Shelby Township, MI 48316 Phone (586) 731-5969 Fax (586) 803-2099 building@shelbytwp.org

More information

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and PREP + INSULATION HOME ENERGY UPGRADES What every contractor needs to know. Copyright 2012 Advanced Energy. All Rights Reserved 103 HOME ENERGY UPGRADES Prep + Insulation Contents Air sealing is a challenging

More information

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers 1 Exam Prep Prov Module: 27203-13 Thermal and Moisture Protection Questions and Answers 1. The R-value is a measure of the ability of a material to. A. Resist the passage of moisture B. Resist heat conduction

More information