1 8/25/2016 PRODUCT DATA ECMS EC-200 SYSTEM COMPOSITE WALL PANEL East Coast Metal Systems, Inc rd Street P.O. Box 217 Bellaire, OH P: F: (740)

2 SYSTEM The Pressure Equalized Rain Screen System is based upon the rainscreen principle and allows incidental water to enter the cladding cavity but then be drained via weep holes. Utilizing formed panels, this system is mounted using aluminum extrusions. Panel joints are finished using color matched or complementary accent strips that float within the extrusions allowing a reveal from 1/2" to 12. The EC-200 system is compatible with 4mm, 6mm, & 8mm ACM Panels.

3 SYSTEM PERFORMANCE TESTING System: Panel Type: Material Options: Core Options: Color: Finish: Substrate: Standard Panel Surface: EC-200 (Dry-Joint) Composite Wall Panel 4-mm, 6-mm, 8-mm Polyethylene-PE, Polyethylene-FR, Phenolic-FR Available in over 100 standard colors through a variety of ACM Suppliers (Request Color Chart or metal samples) Custom Color available Kynar, PEVE, Woodgrain Anodized, Natural Metals available Subgirt or Plywood Smooth Max Panel Width: 60 (1524 mm) 1 Min. Panel Width: Max Panel Length: Min. Panel Length: 4 (101.6 mm) 194 (4927.6mm) 4 (101.6 mm) Test Method Title of Test Results ASTM E 330 Uniform Load Deflection Pass 3 ASTM E 330 Uniform Load Deflection Pass 3 Test Method Title of Test Results ASTM E Air Infiltration Pass 2,3 ASTM Pressure Cyclic Pass 2,3 ASTM E Static Water Penetration Pass 2,3 AAMA Dynamic Water Penetration Pass 2,3 Note 1. Max panel width subject to change based on vendor material 2. Passes AAMA Test Repots available upon request **Test Date 1/30/16

4 BACKING ROD & SEALANT(BY INSTALLER) 1 2 " 1 EC " 2 EC-201 EC-203 WEEP BAFFLE WEEP HOLE LOW PROFILE POP RIVET 1 2 " P.D. (PANEL DIMENSION) P.H. (PANEL HEIGHT) ACM/MCM ACM/MCM REVEAL 3 FASTENER (BY INSTALLER) WATER BARRIER (B.O.) EC-202 FASTENER (BY INSTALLER) FASTENER (BY INSTALLER) EC-201 EC-202 LOW PROFILE POP RIVET WEEP BAFFLE FLASHING (B.O.) 1 2 " O.A. (OVERALL PANEL SYSTEM DIMENSION) WEEP HOLE 1 TYPICAL HEAD DETAIL 2 TYPICAL HORIZONTAL/VERTICAL JOINT 3 TYPICAL BASE JOINT EC-200 PANEL SYSTEM - ISOMETRIC EC-200 Dry Joint System The EC-200 Metal Composite AAMA System allows minimal water penetration. The minimal amount of water that does penetrate the system drains through weep holes. This system utilizes full length extrusions with 6" clips. The EC-200 utilizes a "floating" panel attached to the extrusion to provide a reveal of 1 2" to 12". The system requires no caulking with the exception of joints at perimeter edges where required. The EC-200 provides a hi-tech, clean look and is easy to install. The EC-200 System is compatible with 4mm, 6mm, & 8mm ACM Panels. P-1

5 EC-200 COMPOSITE PANEL SYSTEM P-8 P-9 P-5 P-6 P-10 P-5 P-6 P-11 P-7 P-11 P-7 P-4 ABBREVIATIONS ACM/MCM = ALUM. OR METAL COMPOSITE MATERIAL B.O. = BY OTHERS O.A. = OVERALL PANEL SYSTEM DIMENSION P.D. = PANEL DIMENSION P.H. = PANEL HEIGHT P.W. = PANEL WIDTH INDEX (P-2): SYSTEM OVERVIEW (P-3): EXTRUSIONS (P-4) - (P-11): SYSTEM DETAILS P-2

6 ATTACHMENT EXTRUSIONS " " 2" 9 16 " " EC-201 EXTRUSION (STARTER STRIP) EC-202 PANEL EXTRUSION 9 16 " 3 4 " EC-203 1/2" JOINT CLIP 3 4 " " 2" " PLATE PANEL RETURN REINFORCEMENT P-3

7 SILL CONDITION P-4

8 HORIZONTAL / VERTICAL JOINT- TYPICAL JOINT P-5

9 HORIZONTAL / VERTICAL JOINT- WIDE JOINT P-6

10 START CONDITION P-7

11 PARAPET CONDITION P-8

12 COPING CONDITION P-8.1

13 INSIDE CORNER CONDITION P-9

14 OUTSIDE CORNER P-10

15 TERMINATION CONDITION P-11

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL ENVELOPE 2000 RAINSCREEN (RS) SYSTEM The Ultimate In Performance In A Dry-Joint System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties

More information

Omniplate Barrier Wall System

Omniplate Barrier Wall System is an economical barrier wall system with visible caulk joints at all horizontal and vertical panel joints. As a barrier wall, serves as the primary weather barrier for the building envelope. It can be

More information

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INSTALLATION SEQUENCE TT 5-8 TT- 13 INSTALLATION SEQUENCE INSTALLATION SEQUENCE TT- 4 TT-10 TT-14 TT-12 TT- 3 TT-11 TT-10 TT- 9 TT-11 TT- 2 INDEX (TT- 0): SYSTEM

More information

Ameriplate. Rain Screen Wall System

Ameriplate. Rain Screen Wall System Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the

More information

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL ENVELOPE 2000 ROUT & RETURN (RR) SYSTEM The Ultimate In Performance In A Wet-Sealed System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties

More information

featuring: RR (Rout & Return) Attachment System RS (RainScreen) Attachment System Envelope2000 Metal Composite Material (MCM)

featuring: RR (Rout & Return) Attachment System RS (RainScreen) Attachment System Envelope2000 Metal Composite Material (MCM) featuring: RR (Rout & Return) Attachment System RS (RainScreen) Attachment System Envelope2000 Metal Composite Material (MCM) THE ULTIMATE IN BEAUTY AND PERFORMANCE. As shop-fabricated systems, the RR

More information

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 07 4243 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below.

More information

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS CONCEALED FASTENED PANELS CFP-12 PANEL INDEX 12 - V0 BASE DETAILS HORIZONTAL JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL

More information

Ameriplate. Rain Screen Wall System

Ameriplate. Rain Screen Wall System Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the

More information

SECTION STAINLESS STEEL WALL PANELS

SECTION STAINLESS STEEL WALL PANELS SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.

More information

Carter Architectural Panels Inc. 221 E. Willis Road A Unit 18 Chandler, AZ Mr. Bruce Bourne

Carter Architectural Panels Inc. 221 E. Willis Road A Unit 18 Chandler, AZ Mr. Bruce Bourne PERFORMANCE EVALUATION OF THE CARTER ARCHITECTURAL PANELS INC. FUSION TM DRILLFREE TM PANEL SYSTEM WALL ASSEMBLY FOR AIR INFILTRATION, WATER PENETRATION AND STRUCTURAL PERFORMANCE Report to: Carter Architectural

More information

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) SECTION 07412 COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

PERFORMANCE EVALUATION OF THE RIVETLESS PANEL SYSTEM IN ACCORDANCE WITH AAMA FOR PRESSURE EQUALIZATION BEHAVIOR & WATER PENETRATION RESISTANCE

PERFORMANCE EVALUATION OF THE RIVETLESS PANEL SYSTEM IN ACCORDANCE WITH AAMA FOR PRESSURE EQUALIZATION BEHAVIOR & WATER PENETRATION RESISTANCE PERFORMANCE EVALUATION OF THE RIVETLESS PANEL SYSTEM IN ACCORDANCE WITH AAMA 508-07 FOR PRESSURE EQUALIZATION BEHAVIOR & WATER PENETRATION RESISTANCE Report to: Carter Fabricating Inc. 326 Deerhurst Drive

More information

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA Existing Yard Security Light Proposed Rooftop Mechanical Screening (Slate Gray) Proposed 3 x4 x 4 x4 Windows Metal Awning Existing Doors Metal Siding(Slate Gray) Trim (Matte Black) 14 14 Proposed Addition

More information

Arcwall. Rain Screen Wall System

Arcwall. Rain Screen Wall System Rain Screen Wall System is an economical drained and back-ventilated rain screen system for both walls and soffits manufactured from formed aluminum or stainless plate. The system combines excellent performance

More information

[Project Name] Section [ ]

[Project Name] Section [ ] Page 1 PART 1 - GENERAL 1.1 SECTION INCLUDES 1.1.1 Design, labor, products, equipment and services necessary for interior/exterior Aluminum Facade System (AFS) work, in accordance with the Contract Documents.

More information

EC-250 AAMA Pressure-Equalized Aluminum Plate Rainscreen East Coast Metal System

EC-250 AAMA Pressure-Equalized Aluminum Plate Rainscreen East Coast Metal System EC-250 AAMA 508-07 Pressure-Equalized Aluminum Plate Rainscreen East Coast Metal System SECTION 074213.16 ALUMINUM PLATE PANELS PART 1 GENERAL 1.1 SECTION INCLUDES A. ALUMINUM PLATE PANELS USED AS EXTERIOR

More information

SPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels

SPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels SPECIFICATIONS FOR (1/13 Edition) CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System Section 074243 Aluminum Composite Panels (Based upon CEI Composite Materials R4000

More information

All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION SECTION 07 42 43 All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION SPEC NOTE: Optional text is indicated by square brackets []. Delete unwanted items and

More information

Arcwall. Rain Screen Wall System

Arcwall. Rain Screen Wall System Arcwall Rain Screen Wall System Arcwall is an economical drained and back-ventilated rain screen system for both walls and soffits manufactured from formed aluminum or stainless plate. The system combines

More information

Carter Fabricating Inc. 326 Deerhurst Drive Brampton, Ontario L6T 5H9. Mr. Mike Libreiro

Carter Fabricating Inc. 326 Deerhurst Drive Brampton, Ontario L6T 5H9. Mr. Mike Libreiro PERFORMANCE EVALUATION OF THE CARTER FABRICATING INC. EVO RIVETLESS PANEL SYSTEM WALL ASSEMBLY FOR AIR INFILTRATION, WATER PENETRATION AND STRUCTURAL PERFORMANCE Report to: Carter Fabricating Inc. 326

More information

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana Architectural Testing TEST REPORT Report No.: D0162.01-201-44 Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana PRODUCT TYPE: Pressure Equalized Rainscreen SERIES/MODEL: 4 mm Composite

More information

FACE CFP - HORIZONTAL PANELS - OPTION 'B'

FACE CFP - HORIZONTAL PANELS - OPTION 'B' - Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF

More information

TEST REPORT. Report No.: F Rendered to: FAIRFIELD METAL, LLC Fairfield, New Jersey

TEST REPORT. Report No.: F Rendered to: FAIRFIELD METAL, LLC Fairfield, New Jersey TEST REPORT Report No.: F399.01-109-44 Rendered to: FAIRFIELD METAL, LLC Fairfield, New Jersey PRODUCT TYPE: ACP Panel System (Dry Seal) SERIES/MODEL: Dry Econect-RS Title Design Pressure Air Infiltration

More information

SECTION ALUMINUM COMPOSITE WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SECTION ALUMINUM COMPOSITE WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.*** ***This section has been updated to IBC. Verify for specific project conditions.*** PART 1 GENERAL 1.1 SUMMARY ***Edit to project requirements*** A. Section Includes: 1. Aluminum faced, thermoplastic core,

More information

rout & return INSTALLATION GUIDE

rout & return INSTALLATION GUIDE rout & return INSTALLATION GUIDE Effective October 2016 Tech Support: 800.523.2347 LaminatorsInc.com TABLE OF CONTENTS Handling and Maintenance of Omega-Lite Panels 1 System Limitations and Pre-Installation

More information

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS SECTION 08 4113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Aluminum entrance doors and frames. 2. Glass infill panels. 3. Door hardware. B. Related Sections:

More information

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>. SECTION 074213.23 METAL COMPOSITE MATERIAL WALL PANELS PART 1 GENERAL 1.1 SUMMARY A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary supports and anchors to structure,

More information

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM SECTION 07400 TERRA COTTA CLAY TILE RAINSCREEN SYSTEM PART 1 GENERAL 1.01 WORK INCLUDED A. The terra cotta clay tile elements and aluminum support system shall be manufactured by NBK Keramik GmbH as represented

More information

Sculpted 3D Minimal. Rain Screen Wall System

Sculpted 3D Minimal. Rain Screen Wall System Sculpted 3D Minimal Rain Screen Wall System Metalwërks Sculpted frees designers to create iconic facades more easily and affordably than ever before by elevating three-dimensional wall panels to entirely

More information

TEST REPORT. Report No.: F Rendered to: ALTECH PANEL SYSTEMS, LLC Cartersville, Georgia

TEST REPORT. Report No.: F Rendered to: ALTECH PANEL SYSTEMS, LLC Cartersville, Georgia TEST REPORT Report No.: F7657.01-550-44 Rendered to: ALTECH PANEL SYSTEMS, LLC Cartersville, Georgia PRODUCT TYPE: Metal Wall Panel System SERIES/MODEL: Low Profile Accu-Trac System ES with Stiffeners

More information

SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide

More information

[Project Name] Section [ ] SINTERED CERAMIC FACADE SYSTEM (SCFS) Page 1

[Project Name] Section [ ] SINTERED CERAMIC FACADE SYSTEM (SCFS) Page 1 Page 1 PART 1 - GENERAL 1.1 SECTION INCLUDES 1.1.1 Design, labor, products, equipment and services necessary for large format interior/exterior Sintered Ceramic Facade System (SCFS) work, in accordance

More information

Siding and Soffit Installation Guidelines

Siding and Soffit Installation Guidelines Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field

More information

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>. SECTION 074213.23 METAL COMPOSITE MATERIAL WALL PANELS PART 1 GENERAL 1.1 SUMMARY A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary supports and anchors to structure,

More information

DRY SEAL INSTALLATION GUIDE

DRY SEAL INSTALLATION GUIDE DRY SEAL INSTALLATION GUIDE Effective September 2015 Tech Support: 800.523.2347 LaminatorsInc.com TABLE OF CONTENTS Handling and Maintenance of Omega-Lite Panels 1 System Limitations and Pre-Installation

More information

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002 SECTION 07 42 13 ALUMINUM PLATE PANEL SYSTEM ALPLY Insulated Panels Alply TECH WALL Aluminum Plate System 2002 PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Preformed Aluminum Plate System for Screen wall

More information

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section. SECTION 10 5300 ALUMINUM WALKWAY COVERS Part 1 General 1.01 Related Documents A. The requirements of Division 1 specifications shall apply to work specified in the section. 1.02 References A. International

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD. 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 1687 Reissued 02/2016 This report is subject to renewal 02/2017. DIVISION: 07 00 00 THERMAL

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY #smr_elev 5b SEC 2 8i SEC 2 33 SEC 4 1a SEC 2 37 SEC 4 36 SEC 4 35 SEC 4 SOFFIT FRONT 6d SEC 2 7a SEC 2 SOFFIT REAR INSIDE CORNER (REAR) OUTSIDE CORNER (FRONT) 10a SEC 2 9b SEC 2 4e SEC 2 ELEVATION FOR

More information

TERRART LIGHT. Terracotta Façades

TERRART LIGHT. Terracotta Façades TERRART LIGHT Terracotta Façades 800.727.8953 www.hunterdouglascontract.com/facades 1 TERRART LIGHT Terracotta Façades The NBK TERRART Light system makes the beauty of terracotta facade tiles available

More information

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651 SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651 PART 1 GENERAL 1.1 DESCRIPTION A. Work Included: 1. Furnish all labor and materials to complete the fabrication of detention windows as

More information

Guide Specification for the OSI QUAD Window and Door Flashing System

Guide Specification for the OSI QUAD Window and Door Flashing System Henkel Corporation 26235 First Avenue Westlake, OH 1-866-591-2178 www.ositough.com Guide Specification for the OSI QUAD Window and Door Flashing System Specifier Note: The purpose of this guide specification

More information

SPECIFICATIONS Section Cantilevered Walkway Cover

SPECIFICATIONS Section Cantilevered Walkway Cover Part 1: General 1.1 Related Documents SPECIFICATIONS Section 107301 Cantilevered Walkway Cover A. The requirements of Division 1 specifications shall apply to work specified in the section. 1.2 Engineering

More information

Siding and Soffit Installation Guidelines

Siding and Soffit Installation Guidelines Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field

More information

Guide Specifications- Section

Guide Specifications- Section Guide Specifications- Section 084113 LaCantina ALUMINUM Folding Door System PART 1 GENERAL 1.01 SECTION INCLUDES A. Aluminum and glass folding door system with fingertip operation up to 52 wide and 10

More information

EMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS

EMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS SECTION 074213.23 - WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Installation Manual A Rollfab Metal Products, Aluma-Kor is a registered trademark of Rollfab Metal Products. 1 P a g e

Installation Manual A Rollfab Metal Products, Aluma-Kor is a registered trademark of Rollfab Metal Products. 1 P a g e Installation Manual A1000 2013 Rollfab Metal Products, Aluma-Kor is a registered trademark of Rollfab Metal Products 1 P a g e INTRODUCTION Aluma-Kor aluminum composite material (ACM) is the building material

More information

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM STORM WINDOWS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 08 51 69.11 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

Guideline Specifications

Guideline Specifications Page 1 of 7 PART 1 Guideline Specifications Exterior Aluminum/Composite Wall Panels GENERAL ARROWHEAD 508 SYSTEM Pressure Equalized Rainscreen SECTION 07410 1.01 SUMMARY A. Work of this section included

More information

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels. 1/11 SECTION 074213.23 - ALUMINUM COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes aluminum composite material wall panels. 1.2 PRE-INSTALLATION MEETINGS A. Pre-installation

More information

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS SECTION 07 42 13.26 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Zinc alloy metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

TECHNICAL BULLETIN. MCM Panel System Definitions. Overview. Discussion. Original Basic Installation Systems

TECHNICAL BULLETIN. MCM Panel System Definitions. Overview. Discussion. Original Basic Installation Systems TECHNICAL BULLETIN MCM Panel System Definitions Overview Metal Composite Material (MCM) has been used as a means of exterior cladding in North American construction for more than 40 years. In order for

More information

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.*** ***This section has been updated to IBC. Verify for specific project conditions.*** PART 1 GENERAL 1.1 SUMMARY ***Edit to project requirements*** A. Section Includes: 1. Clear copper and preweathered copper

More information

Architectural Wall Products Guide Specifications

Architectural Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is

More information

SECTION EXTERIOR GRILLS AND SCREENS

SECTION EXTERIOR GRILLS AND SCREENS SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,

More information

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. SECTION 08625 METAL FRAMED SKYLIGHT PART 1 GENERAL 1.01 SECTION INCLUDES: A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. B. Fabrication

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS 1. PART 1 GENERAL 1.1 WORK INCLUDED: 1. Provide labor, material, equipment and services to furnish and install aluminum windows shown on drawings and specified herein. Window

More information

Ultra Wall System. CAD Detail Sets

Ultra Wall System. CAD Detail Sets Ultra Wall System CAD Detail Sets Contents Page UWS-CM CAVITYMATE Ultra Contents 1-0 FOR: Details continuing on 1-1 thru 1-17 Cavity cut XPS board to fit between ladder tie masonry ties in CMU walls UWS-SL

More information

CENTRIA FORMABOND II Metal Composite Wall System

CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FormaBond II is the only true metal composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer

More information

SECTION METAL COMPOSITE MATERIAL WALL PANELS

SECTION METAL COMPOSITE MATERIAL WALL PANELS SECTION 074213.23 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System CENTRIA Intercept Entyre is a unique modular metal wall system designed, available from a reliable national manufacturer and supported

More information

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM RAINSCREEN (H&J) SYSTEM INSTALLATION DATA & DETAILS Omnis Panels, Inc. Architectural Building Panels 22 East Chicago Avenue Suite 210 Naperville, Illinois 60540 (800) 450-6099 (630) 355-4040 Fax: (630)

More information

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM RAINSCREEN (H&J) SYSTEM INSTALLATION DATA & DETAILS Omnis Panels, Inc. Architectural Building Panels 22 East Chicago Avenue Suite 210 Naperville, Illinois 60540 (800) 450-6099 (630) 355-4040 Fax: (630)

More information

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1 Fitness Facility Addition Page 1 PART 1 GENERAL 1.1 SECTION INCLUDES.1 Extruded aluminum windows with fixed sash..2 Factory glazed..3 Perimeter sealant. 1.2 RELATED SECTIONS.1 Section 05500 - Metal Fabrications.2

More information

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants. Section 07 42 13 Page 1 PART 1 GENERAL 1.1 SECTION INCLUDES A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants. 1.2 RELATED SECTIONS A. Section 06112 - Framing

More information

EVO ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

EVO ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION SECTION 07 42 43 EVO ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION SPEC NOTE: Optional text is indicated by square brackets []. Delete unwanted items and square brackets in final specification.

More information

Expansion Joint Covers

Expansion Joint Covers Expansion Joint Covers 07 95 00 (079513) PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Supplementary Conditions and Division-1

More information

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE: SECTION 07651 FLEXIBLE COPPER SHEET FLASHINGS Advanced Building Products, Inc. manufacturer many types of flexible copper sheet flashings. Due to their ductility, high tensile strength, and resistance

More information

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Guide Specifications- Section

Guide Specifications- Section Guide Specifications- Section 084113 LaCantina ALUMINUM Folding Door System PART 1 GENERAL 1.01 SECTION INCLUDES A. Aluminum and glass folding door system with fingertip operation up to 52 wide and 10

More information

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION 08410 ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS This suggested guide specification has been developed using

More information

EIFS Rain Control EIFS. Face Sealed Perfect Barrier. Beware of EIFS: They must be done correctly They leak at joints Avoid moist sensitive substrate

EIFS Rain Control EIFS. Face Sealed Perfect Barrier. Beware of EIFS: They must be done correctly They leak at joints Avoid moist sensitive substrate EIFS Rain Control Both Drained and Perfect Barrier can be used Joints and Element can be designed differently Face Sealed Perfect Barrier The problem wall of the past Relies on sealant = dangerous Often

More information

TEST REPORT. Report No.: G Rendered to: CR LAURENCE CO., INC. Vernon, California

TEST REPORT. Report No.: G Rendered to: CR LAURENCE CO., INC. Vernon, California TEST REPORT Report No.: G9949.01-303-47 Rendered to: CR LAURENCE CO., INC. Vernon, California PRODUCT TYPE: Fixed Lite Storefront System SERIES/MODEL: IT451 Title Summary of Results Design Pressure ±1440

More information

Expansion Joint Covers (079513)

Expansion Joint Covers (079513) Expansion Joint Covers 07 95 00 (079513) PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Supplementary Conditions and Division-1

More information

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM STORM WINDOWS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 08 51 69.11 ALUMINUM STORM WINDOWS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 4 5 6 8 18 13 10 15 SOFFIT OUTSIDE CORNER INSIDE CORNER 16 17 3 19 20 11 9 OPENING 12 END WALL 14 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY EH-01 INDEX EH-02 STANDARD PANEL OFFERING EH-03 SIDE LAP DETAILS

More information

AL13. Intro. Vol 2 AL13. architectural panel system. Version 1. patent pending

AL13. Intro. Vol 2 AL13. architectural panel system.   Version 1. patent pending 01 AL13 Intro AL13 architectural panel system Vol 2 Version 1 www.al13.com patent pending CLAD THE WORLDTM 01 System Overview AL13 has changed the game. Our metal panel system is cut to fit and snaps together

More information

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 074213 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope. SECTION 08 4519 - POLYCARBONATE WALL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior System: The design, manufacture and installation of an aluminum and polycarbonate insulating translucent system.

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS SECTION 07 4213.29 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Textured, aluminum metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support

More information

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ORNAMENTAL ALUMINUM RAILING SECTION 05730 ORNAMENTAL ALUMINUM RAILING PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Pipe Railing 1.2 RELATED SECTIONS A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in concrete.

More information

Blast Curtain Wall Installation Analysis

Blast Curtain Wall Installation Analysis August 11, 2005 57402.01-122-34 JAR/STS 1 US Aluminum BR3250 Blast C.W. Blast Curtain Wall Installation Analysis Subject: BR3250 Blast Curtain Wall System ATI Report 57402.01-122-34 Rendered to: International

More information

CENTRIA Concept Series Metal Wall Panels ZINC

CENTRIA Concept Series Metal Wall Panels ZINC CENTRIA Concept Series Metal Wall Panels ZINC CENTRIA Concept Series Metal Wall Panels are a versatile design choice for wall cladding panels. They are manufactured with a variety of profiles and five

More information

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV

More information

SECTION B3 SERIES COS451 FRONT GLAZED STACKING SYSTEM

SECTION B3 SERIES COS451 FRONT GLAZED STACKING SYSTEM SECTION B SERIES COS51 FRONT GLAZED STACKING SYSTEM for STOREFRONT / WINDOW WALL x ½ for 1 GLASS ARCHITECTURAL DETAILS EXTERIOR GLAZED Effective October 01 www.cardcompro.com 1 INTERIOR GLAZED www.cardcompro.com

More information

METAL COMPOSITE MATERIAL WALL PANELS

METAL COMPOSITE MATERIAL WALL PANELS MasterSpec Full Length 1 of 10 SECTION 074213.23 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes metal composite material wall panels. 1.2 PREINSTALLATION MEETINGS

More information

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions Thank you for purchasing the Genesis Dura-Max Brick Panel system for your project. The system allows you to have the look

More information

TYPICAL ROOF CONDITION LAYOUT

TYPICAL ROOF CONDITION LAYOUT FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Aluminum Composite Material (PE) Section 07420

Aluminum Composite Material (PE) Section 07420 Specification INC. Aluminum Composite Material (PE) Section 07420 PART 1 - GENERAL 1.01 Summary A. Section Includes 1. The extent of panel system work is indicated on the drawings and in these specifications.

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Ice Rink Renovation & New Clubhouse

Ice Rink Renovation & New Clubhouse SECTION 074243- METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 074243 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification

More information

Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide

Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide Flushglaze 7500 For Steel Tube pplications and Horizontal Panels Façades Installation Guide September 2016 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal

More information

CENTRIA FORMABOND. Aluminum Composite Wall System

CENTRIA FORMABOND. Aluminum Composite Wall System CENTRIA FORMABOND Aluminum Composite Wall System CENTRIA FormaBond is the only true aluminum composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer

More information