PRECAST RECTANGULAR CHAMBERS
|
|
- Francis Mathews
- 6 years ago
- Views:
Transcription
1 STANDARD MODELS GENERAL ROUGH SKETCH Available for: Sewer manhole, valve chamber, trouser manhole, and pumping station. Ø60-Ø762 ADJUSTMENT RING RING ø 6 FLAT REDUCER SLAB H H2 RUBBER GASKET H3 BASE H EXTRA WIDTH ON REQUEST BOTTOM H L2 L3 0 7 L
2 CHART AND INDEX STANDARD MODELS PRECAST RECTANGULAR CHAMBERS L L2 L3 H H2 H3 H H MODEL INTERIOR INTERIOR REDUCER HEART MAX WEIGHT /LIN. MAX WEIGHT / BOTTOM MAXIMUM LENGTH LENGTH THICKNESS SLAB CHAMFER HEIGHT METER BASE HEIGHT LIN. METER THICKNESS DIAMETER THICKNESS (kg) (kg) OF THE DUCTS RR RR RR RR RR RR RR * All dimensions are in millimeters. LEGEND Galvanized steel ladder, by section Ducts (PVC, cast iron, polyethylene, steel, R.C.P.) Sumps or drain (0ptionnal) Hoisting Cable Handling socket Polyethylene covered Rung Circular or rectangular opening (Access trap) Embedded rubber gasket according to the type and the diameter of the pipe Rubber gasket for gravitating PVC Ø300) Perforated opening for: existing pipe, pipe with pronounced slope and angle, Link-seal To determine the slope and maximum angle of the pipes, please communicate with our engineering department
3 DIMENSIONS MODELS SEWER MANHOLE + Available in particular cases with a factory made benching. + Filler concrete provided and installed by the customer. + Length and width dimensions within 00 mm range. + For transportation, at least one of the exterior dimensions (width or length) must be inferior to 00 mm. Ø600 or Ø70 RING FLAT REDUCER RING BUTYL CORD Ø9 BASE FLOOR BENCHING BENCHING
4 DIMENSIONS MODELS TROUSER MANHOLE / MANHOLE WITH CHUTE + Filler concrete provided and installed by the customer. + Length and width dimensions within 00 mm range. + For transportation, at least one of the exterior dimensions (width or length) must be inferior to 00 mm. 600ø or 70ø BUTYL CORD HEIGHT BASE DEFLECTOR (C.S.P.) ØEXT. + 0 mm
5 DIMENSIONS MODELS GATE VALVE CHAMBER + Filler concrete and/or support block (if necessary) provided and installed by the customer. + Length and width dimensions within 00 mm range. + For transportation, at least one of the exterior dimensions (width or length) must be inferior to 00 mm. Ø600 or Ø70 RING FLAT REDUCER RING BUTYL CORD 7 Ø9 BASE HEIGHT 2 FLOOR DRAIN
6 DIMENSIONS MODELS SPILLWAY MANHOLE + Filler concrete provided and installed by the customer. + Length and width dimensions within 00 mm range. + For transportation, at least one of the exterior dimensions (width or length) must be inferior to 00 mm. VENT ACCESS TRAPS VALVE CHAMBER SLAB ACCESS TRAPS BUTYL CORD OUTLET BASE HEIGHT FLOOR EMBEDDED SLEEVE
7 DIMENSIONS MODELS ANGULAR CHAMBERS + Available in certain cases with a factory made benching. + Filler concrete (if needed) provided and installed by the customer. + Length and width dimensions within 00 mm range. + For transportation, at least one of the exterior dimensions (width or length) must be inferior to 00 mm. Ø600 or Ø70 BUTYL CORD RING FEMALE JOINT FOR THE CONCRETE PIPE FLAT REDUCER RING ANGLE BASE HEIGHT Ø9 MALE JOINT FOR CONCRETE PIPE FLOOR
8 DIMENSIONS MODELS PUMPING STATION + Filler concrete provided and installed by the customer. + Length and width dimensions within 00 mm range. + For transportation, at least one of the exterior dimensions (width or length) must be inferior to 00 mm. BRACKET BASE ACCESS TRAP BUTYL CORD ACCESS TRAP BASE BASE HEIGHT FLOOR
9 STEEL LADDER RUNG LADDER RUNG LADDER 3 X 6 FLAT IRON X 6 FLAT IRON CRENELATED STEEL BAR mm 300 c/c (type) 0 2 RUNG LADDER 3 X 6 FLAT IRON (type) CRENELATED STEEL BAR mm 300 c/c (type) 0 0 (type) Galvanized crenelated steel bar mm ALSO AVAILABLE LOWERED RUNG COVERED WITH POLYETHYLENE (See reinforced circular concrete manholes) 3 RUNG LADDER RUNG LADDER 3 X 6 FLAT IRON 300 c/c (type) X 6 FLAT IRON 390 CRENELATED STEEL BAR mm 300 c/c (type) 0 (type) CRENELATED STEEL BAR mm 0 0 (type)
10 TECHNICAL DATA SHEET STANDARDS The concrete, the reinforcement steel and the rubber gaskets or liners meet the standard NQ HANDLING The riser rings and the top slabs of Ø9 mm are provided with plastic casings embedded in the concrete. These casings are for the fasteners of the hoisting and handling equipment. The other elements of the manholes are provided with hoisting cables allowing for a secure handling of the elements in the factory and on the building site. The customer will facilitate his work by using the suitable handling harnesses for the unloading and the installation of the manhole. An inadequate handling can produce breakings, which would irremediably affect the structure of the manhole and it s watertightness. INSTALLATION GUIDELINES The surfaces of the fittings and the rubber gaskets must be clean. In accordance with the standard NQ , the lubricant used must be the one provided by the manufacturer of the pipe. The use of another lubricant can restrain or cancel the responsibility of the manufacturer in regards to the watertightness or physical characteristics of the rubber gaskets. The abundant use of lubricant is recommended during the fitting of rings and pipes. The Ø9mm rings require a minimum of 00g of lubricant per gasket. Manholes will have to be set up according to the sequence pointed out in the workshop drawings. The riser rings will be installed according to a height diminishing order. The desired profile will be obtained according to the workshop drawings. Precautions must be taken to prevent the contact of oil or sulphur based products with the rubber gaskets, which would deteriorate and become unusable
0.75 " transparent hose w/ valve for head measurements fixed to screws 20 MIL PVC liner. 6" gate valve
0.75 " transparent hose w/ valve for head measurements fixed to screws 250x1000 RC beam 6" gate valve Foundation preparation in accordance with technical specifications and as approved by engineer 25 cm
More informationAPPLICABILITY TABLE. Council BSC CHRC GRC IRC LSC MRC RRC Applicable Yes Yes Yes Yes Yes Yes Yes
Precast roof slabs refer Standard Drawing CMDG-D-03 Special cast iron cover and frame, refer Service Authority. Special cast iron cover and frame, refer Service Authority. Cast iron cover and frame Ø 200
More informationONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,
VENT CAP (MUSHROOM TYPE) SOLID CAP EXIST GRADE MIN BUILDING REFER TO NOTE #4 MIN CONCRETE SIDEWALK CURB OR EDGE OF SIDEWALK STREET CLEANOUT (REFER TO NOTE #3) VENT PIPE 4" PVC 6" PVC CLEANOUT CONCRETE
More informationBelow ground System of pipework required to carry waste fluids from building to disposal site.
1 Below ground System of pipework required to carry waste fluids from building to disposal site. Disposal site County Council sewage treatment facility. Septic tank system or alternative systems 2 1. Layout
More informationFacility Sanitary Sewers
University of New Hampshire University of New Hampshire Scholars' Repository Division 22 Plumbing Chapter 5 Technical Construction and Renovation Standards 4-23-2015 221313 - Facility Sanitary Sewers Sandra
More informationSANITARY MANHOLE S-1 ENGINEERING DEPARTMENT PLATE NUMBER NEENAH R-1733 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL.
"INFI-SHIELD" SEAL OR EQUAL. NEENAH R-1733 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL. 27" HDPE ADJUSTING RINGS (2 MIN., 1' MAX. OF RINGS). ECCENTRIC CONE 4.0' HIGH 48" 5" P2 PROFILE GASKET
More informationAMENDMENTS TO OPSS 408 (OCT 89) CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MANHOLES, CATCH BASINS, DITCH INLETS AND VALVE CHAMBERS
Works and Emergency Services CITY OF TORONTO WATER AND WASTEWATER SERVICES STANDARD CONSTRUCTION SPECIFICATIONS TS 408 November 2010 AMENDMENTS TO OPSS 408 (OCT 89) CONSTRUCTION SPECIFICATION FOR ADJUSTING
More informationSECTION PRECAST CONCRETE MANHOLES
SECTION 03 48 10 PRECAST CONCRETE MANHOLES PART 1: GENERAL 1.01 SECTION INCLUDES A. Precast concrete manholes for sanitary sewers and water lines or as indicated on the Drawings. B. Precast concrete sanitary
More informationCONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS
ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.PROV 602 NOVEMBER 2017 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS TABLE OF CONTENTS 602.01 SCOPE 602.02 REFERENCES 602.03 DEFINITIONS
More informationCONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 602 MARCH 1993 CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER 602.01 SCOPE 602.02 REFERENCES 602.05 MATERIALS TABLE OF CONTENTS
More informationCOLDSTREAMCONCRETE.COM
PRODUCT GUIDE 2017 TABLE OF CONTENTS 3 BOX CULVERTS 5 6 BOX MAINTENANCE HOLES & UTILITY CHAMBERS FLAT HEADWALL - 804.03 7 V-TYPE HEADWALLS - 804.04 8 HEADWALL GRATES - 804.05 9 MAINTENANCE HOLES 15 CATCH
More informationCOLDSTREAMCONCRETE.COM
PRODUCT GUIDE TABLE OF CONTENTS 3 BOX CULVERTS 5 OPSD 804.04 V-TYPE HEADWALL 6 OPSD 804.03 FLAT HEADWALL 7 HEAD WALL GRATES 8 12 MAINTENANCE HOLES AND CATCH BASINS REINFORCED CONCRETE PIPE 15 MUNICIPAL
More informationCPM Concrete Drainage Systems
CPM Group Ltd offer a complete range of precast concrete manhole units from DN 900 to DN 4000 in varying depths with tongue and groove joints. A djusting units Ductile iron cover & frame Cover slab DN1200
More informationSECTION FACILITY SANITARY SEWERS
SECTION 22 13 13 FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationPERMANENT PAVEMENT REPAIR NO SCALE
SAWCUT EXISTING PAVEMENT 2" BITUMINOUS CONCRETE SURFACE COURSE, CLASS 2 (MIN) CLEAN EDGE PRIOR TO PAVING AND PAINT WITH LIQUID BITUMEN. INSTALL SEALANT OVER JOINT UPON COMPLETION 2" BITUMINOUS CONCRETE
More informationPipe to Manhole Connectors, Sealants. Pipe to Manhole Connectors, Sealants
ITUPLAST Preformed Butyl Mastic Connector An excellent product of the NPC Company, USA. General Ituplast is a special gasket/sealant intended for sealing between sections of the sewage and drainage inspection
More informationStorm Drainage
University of New Hampshire University of New Hampshire Scholars' Repository Division 33 Utilities Chapter 5 Technical Construction and Renovation Standards 4-23-2015 334100 - Storm Drainage Sandra Hickey
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING
SECTION 221316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following soil and waste, sanitary drainage and vent piping inside the building: 1. Pipe, tube,
More informationTCC/SHORE TRANSIT BUS MAINTENANCE FACILITY PHASE II
SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationPRODUCT GUIDE 2019 EFFECTIVE MARCH 25, 2019
PRODUCT GUIDE 2019 EFFECTIVE MARCH 25, 2019 TABLE OF CONTENTS 3 BOX CULVERTS 5 OPSD 804.03 FLAT HEADWALL 6 OPSD 804.04 V TYPE HEADWALL 7 OPSD 804.05 HEADWALL GRATES 8 MAINTENANCE HOLES 15 CATCH BASINS
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping inside the building.
SECTION 221413 - FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following storm drainage piping inside the building. 1. Pipe, tube, and fittings. 2. Special pipe
More informationSUPPLEMENTAL DRAWINGS
CITY OF GREATER SUDBURY SUPPLEMENTAL DRAWINGS TO THE ONTARIO PROVINCIAL STANDARD DRAWINGS Rev: February 2012 CITY OF GREATER SUDBURY STANDARD DRAWINGS TABLE OF CONTENTS Greater Sudbury Standard Drawings
More informationCONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MAINTENANCE HOLES, CATCH BASINS, DITCH INLETS, AND VALVE CHAMBERS
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 408 NOVEMBER 2015 CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MAINTENANCE HOLES, CATCH BASINS, DITCH INLETS, AND VALVE CHAMBERS TABLE OF
More informationPRECAST CONCRETE MANHOLES. A. Precast concrete manholes for sanitary sewers, storm sewers, and water lines.
Section 02082 PART 1 G E N E R A L 1.01 SECTION INCLUDES A. Precast concrete manholes for sanitary sewers, storm sewers, and water lines. B. Precast concrete sanitary sewer manholes with PVC liner where
More informationSECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.
SECTION 33 05 13 MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems. B. Related Sections: 1. Section 03 20 00 - Concrete
More informationPOLYETHYLENE LINED PRODUCTS PROJECTS TABLE OF CONTENTS IMPACT BAFFLES CATCH BASINS MANHOLE MATERIALS LARGE DIAMETER ROUND MANHOLES
2018 www.precon.ca 2 2017 PROJECTS TABLE OF CONTENTS 3 2 PROJECTS 11 POLYETHYLENE LINED PRODUCTS 3 TABLE OF CONTENTS 12 IMPACT BAFFLES 4 CATCH BASINS 13 INLET/TURNOUTS 5 MANHOLE MATERIALS 14 FLARED END
More informationFLOOR AND AREA DRAINS
Pictorial Index Product Recommendations Floor Drain Selection Factors Load Rating Grate Free Area Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations FLOOR AND AREA
More informationDescription Unit Quantity Rate Kshs. Amount Kshs.
BILL No.1 40m3 MASONRY STORAGE TANK No. Description Unit Quantity Rate Kshs. Amount Kshs. 1 SETTING OUT AND EARTH WORKS 1.1 General site clearance and setting out 1.2 Excavate over site 200mm to remove
More informationCONSTRUCTION SPECIFICATION FOR NEW MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 407 NOVEMBER 2015 CONSTRUCTION SPECIFICATION FOR NEW MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION TABLE OF CONTENTS 407.01
More informationSECTION STORM DRAINAGE
SECTION 02720 STORM DRAINAGE PART 1 - GENERAL 1.01 WORK INCLUDED A. Trenching and other excavation. B. Ground water control. C. Pipe bedding. D. Installation of storm drains and appurtenances. E. Installation
More informationSANITARY WASTE AND VENT PIPING
SECTION 15420 - SANITARY WASTE AND VENT PIPING PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationB. Fiberglass for construction in back lot easements placed on cast-in-place base.
Section 02083 PART 1 G E N E R A L 1.01 SECTION INCLUDES A. Fiberglass manholes for unpaved areas placed on top of a precast base to form a manhole. B. Fiberglass for construction in back lot easements
More informationMiscellaneous and Cast Iron Listings
aeconcrete.com May 2017 Miscellaneous and Cast Iron Listings Drawing Number Item Description Product Size (Length X Width X Depth in mm) SVVZ-20-SUMP-C Drainage Sump w/ Cover 660 x 510 x 765 i.d. SVVZ-NC-SUMP-C
More informationCITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER
CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER WATER MAIN 1. All open cut water main shall be polyvinyl chloride plastic (PVC) pressure pipe per AWWA specification
More informationCI/SfB Oct 12 (52.5) Uniclass L7314
CI/SfB Oct 12 (52.5) Uniclass L7314 Bailey Flow-therm Product Selector A RANGE OF QUALITY AND ROBUST RAINWATER OUTLET AND VENTILATION SYSTEMS FOR FLAT ROOFS, MANUFACTURED FROM RIGID POLYURETHANE. Bailey
More informationITEM No. D E S C R I P T I O N UNIT QTY. 5-E343.2 In class III material m³ 1,260 - Max. Depth: m For disposal
EARTHWORKS Excavation for foundations 5E343.2 In class III material m³ 1,260 Max. Depth: 0.50 1 m For disposal 5E334.2 In class III material m³ 720 Max. Depth: 1 2 m For disposal Filling Ancillaries 5E723.0
More informationDIVISION 3: SEWER. Improvement Design Standards City of Dundee Oregon. Division 3 : Sewer Page 1
DIVISION 3: SEWER 3.1 DESIGN CRITERIA A. APPLICABILITY 1. These Design Standards shall govern all construction and upgrading of public sanitary sewer facilities in the City of Dundee and applicable work
More informationCI/SfB Oct 12 (52.5) Uniclass L7314
CI/SfB Oct 12 (52.5) Uniclass L7314 Bailey Flow-therm Product Selector A RANGE OF QUALITY AND ROBUST RAINWATER OUTLET AND VENTILATION SYSTEMS FOR FLAT ROOFS, MANUFACTURED FROM RIGID POLYURETHANE. Bailey
More informationCONCRETE PIPES CONCRETE PIPES FACTORY. Since Concrete. Slabs (Cover) for Cable. Trench Jacking. Jacking Pipes. Non & Reinforced. without.
CONCRETE PIPES Gullies Manholes Intermediate Jacking s with Steel Sleeve Non & Reinforced Concrete s Concrete Slabs (Cover) for Cable Half Round Wheel Stopper Trench Jacking CONCRETE PIPES FACTORY Since
More informationPASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017
SECTION 02630 - STORM DRAINAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More information1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork.
PAGE 334000-1 SECTION 334000 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,
More informationNew Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M
SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationEFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection
EFFECTIVE FEBRUARY 2014 note: drainage permit required to call for a dampproof inspection PERMITS & INSPECTIONS 750 17th Street West Vancouver BC V7V 3T3 westvancouver.ca/permits t: 604-925-7040 f: 604-925-7234
More informationCurrent Standard Plates including Transmittal Letters are available on the web at:
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (6-03) MANUAL: Standard
More informationSECTION XXXX POLYMER CONCRETE PUMP STATIONS
SECTION XXXX POLYMER CONCRETE PUMP STATIONS PART 1 GENERAL 1.1 SUMMARY A. This specification shall govern for the furnishing of all work necessary for installation of polymer concrete pump stations to
More informationA. Piping materials shall bear label, stamp, or other markings of specified testing agency.
SECTION 221316- PART 1- GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe, tube, and fittings. 2. Specialty pipe fittings. 1.2 INFORMATIONAL SUBMITTALS A. Field quality-control reports. 1.3 QUALITY ASSURANCE
More informationStudent Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:
SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Roof flashing
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:
SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Roof flashing
More informationCentral Concrete Product Limited. Product Catalogue
January 2007 Concrete Pipes Reinforced Concrete Pipe Internal Wall Thickness Pipe Strengths Pipe Pipe Weight Diameter (mm) Length (kg) (mm) B Wall C Wall B Wall C Wall (mm) B Wall C Wall 300 50 n/a Class
More informationSECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION
Page 210500-1 SECTION 210500 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationChanges for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details
Changes for the 2017 TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details The following changes are made to the existing standards and details to clarify or improve existing information.
More informationTABLE OF CONTENTS
DIVISION 33: SEWER AND SEPTIC SYSTEMS 33 3633 UTILITY SEPTIC TANK DRAINAGE FIELD TABLE OF CONTENTS 33 0000-1 SECTION 33 3633-- UTILITY SEPTIC TANK DRAINAGE FIELD PART 1 - GENERAL 1.1 SUMMARY A. Includes
More informationDelivering Reliability. Electrical Vaults. Power & Energy-Underground Structures
A Delivering Reliability Electrical Vaults Power & Energy-Underground Structures A The Benefits of Precast Vaults Electrical vaults house power cables and transformers, and are a preferred alternative
More informationUnit Rate. Subtotal in SDG. Site Clearing Preliminary Works. 1.0 Job. Excavation & Earth Works. Stone Masonry Works in foundation 100 M.
Bill of Quantities Nature of work : Construction of Health Center with 8 rooms (Clinics, Pharmacy, Labs, Fence & Latrines) Location: Shakreen- El Fasher Town- North Darfur State No. Description Qty Unit
More informationRodding Eye Details. Inspection Chambers
Rodding Eye Details Inspection Chambers 1 2 Deep Inspection Chambers BS7158:2001 Installation Procedures 1. Excavate to the required depth for the Polypipe Non Man Entry Deep Inspection Chamber system
More information16. Design of Pipeline Structures.
16. Design of Pipeline Structures. a. General. 1) The following guidelines are for the design of structures for water and sewer pipelines including structural concrete and miscellaneous metals design.
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 22 1316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationNORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section PRECAST CONCRETE MANHOLES
PART 1 GENERAL 1.01 SUMMARY This Section includes: Section 02082 A. Precast concrete manholes for sanitary sewers, storm sewers and water lines. B. Precast concrete sanitary sewer manholes with PVC liner
More informationSummary of the 2011 Changes
The following is a list of amendments to the Residential Site Improvement s, N.J.A.C. 5:21, adopted in 2011. The Notice of Adoption of these changes appeared in the New Jersey Register on May 16, 2011.
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 33 3400 STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS
SECTION 02530 - SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationStandard Specifications for Road and Bridge Construction. Adopted January 1, 2012
Standard Specifications for Road and Bridge Construction Adopted January 1, 2012 Pipe Culverts Art. 542.02 SECTION 542. PIPE CULVERTS 542.01 Description. This work shall consist of furnishing and installing
More informationTYPE "A" CATCH BASIN
27" 1.67' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN NEENAH CASTING R-3250-BV OR APPROVED EQUAL. "INFI SHIELD" SEAL OR APPROVED EQUAL RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR). PLASTER OUTSIDE,
More informationA. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water.
SECTION 22 1313 - FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationLight-Metal Roof Edge, Raised
NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED
More informationSECTION 39 - MANHOLES TABLE OF CONTENTS
Section SECTION 39 - MANHOLES TABLE OF CONTENTS Page 39-1 GENERAL... 39.1 39-2 CONCRETE MANHOLES... 39.1 39-2.01 NOT USED... 39.1 39-2.02 Concrete Storm Drain Manholes... 39.1 39-3 SADDLE SEWER MANHOLES...
More informationDRAFT. Draft Bill of Quantities. Drainage
Draft Bill of Quantities September 2015 STORM DRAINAGE INFORMATION Measurement notes Drawings used : WYG (80) 140 Rev T1, D-(80) 001 Rev T1, D-(80) 002 Rev T1, D-(80) 003 Rev T1 and D-(80) 004 Rev T1 All
More informationSECTION FACILITY SANITARY SEWERS
PART 1 - GENERAL 1.01 SECTION INCLUDES A. Gravity-flow, non-pressure sanitary sewerage outside the building, with the following components: 1.02 DEFINITIONS 1. Cleanouts. 2. Precast concrete manholes.
More informationThe Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 7
September 2013 Page 1 of 7 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of a wetwell as shown on the Plans and in accordance with Section 01001,
More informationSECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications.
SECTION 13 PIPE, TUBE AND PART 1 - GENERAL 1.01 DESCRIPTION A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications. 1.02 QUALITY ASSURANCE
More informationPerfect Manhole Installation Manual May 2012 Rev 8 Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints
Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints Installation Manual 1 1 Introduction This manual gives guidance on how to install the CPM Group Perfect manhole system
More information(For compliance with the new sewers for adoption regulation or building regulations part H1)
Plastic Drainage Keyline offers a comprehensive range of products suitable for all building, foul, surface water and land drainage applications - including new innovative, cost-effective systems for compliance
More informationSECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS
SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS To prevent the contamination of the public water supplies from nearby sanitary sewers, the following State Water Resources Control Board Division
More information50.20 Drainage Structure Design
50.20 Drainage Structure Design All drainage structures, with the exception of bridges, culvert bridges and, in some cases, culverts, shall be designed for HS20-44 loading. Refer to Section 50.22 for design
More informationMATERIALS STORM DRAIN PIPE TABLE OF CONTENTS
TABLE OF CONTENTS 1. TYPES OF STORM DRAIN PIPE AND JOINTS...2 2. MANHOLES, CATCH BASINS AND INLETS BLOCK AND BRICK...3 3. PRECAST MANHOLES, CATCH BASINS AND INLETS...4 4. STORM DRAIN STUBS...4 5. STORM
More informationA Provide for Contractor's Office, Store etc. Sum
BILL NO.1 - PRELIMINARIES AND GENERAL CONDITIONS A Provide for Contractor's Office, Store etc. Sum B C Provide for Insurance in accordance with the Conditions of the Contract. Allow for the provision of
More informationSTANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING
STANDARD CONSTRUCTION DETAILS REVISED MARCH 2018 GENERAL NOTES EMBEDMENT DETAILS EMBEDMENT DETAILS TWO-WAY CLEANOUT - EXISTING LATERAL TWO-WAY CLEANOUT - NEW CONSTRUCTION TYPICAL SEWER HOUSE SERVICE CONNECTION
More informationCITY OF FARGO SPECIFICATION SANITARY SEWER
SECTION 1200 SECTION 1200 CITY OF FARGO SPECIFICATION SANITARY SEWER PART 1 DESCRIPTION OF WORK (revised March, 2007) The work to be done under these Specifications and the accompanying drawings consist
More informationTerrain HDPE. Product Guide
TAGIG1-PT JULY 2009 Terrain HDPE Product Guide Terrain HDPE BBA BRITISH BOARD OF AGRÉMENT CERTIFICATE No. 07/4479 A modern high density polyethylene system with many advantages over cast iron and other
More information1.1 SECTION INCLUDES.1 Materials and installation for water mains, hydrants, valves, valve boxes, and valve chambers, including service connections.
Issued 2005/06/01 Section 02511 Water Mains Page 1 of 10 PART 1 GENERAL 1.1 SECTION INCLUDES.1 Materials and installation for water mains, hydrants, valves, valve boxes, and valve chambers, including service
More informationCATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE
3.33' 3.0' 2.0' 4.33' 4.0' 3.0' 1.00' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN NEENAH CASTING R-3067-V OR AS NOTED ON PLANS. "INFA-SHIELD" SEAL OR EQUAL. RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR).
More informationDUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS
DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS General All Materials shall be EN, ISO or equivalent standard and shall be supplied from approved manufacturers. According to the International
More informationINSTALLATION. Step 6. Step 7. Step 8
INTLLTION The following installation instructions and the relative drawings are given only as an example not considering any peculiarities of the installation site or soil characteristics, or morphology
More informationSECTION 300 STORM SEWER TABLE OF CONTENTS
SECTION 300 STORM SEWER TABLE OF CONTENTS Starts on Page 300 GENERAL... 2 301 MATERIALS... 2 302 CONSTRUCTION PROCEDURES... 5 303 TESTING... 5 304 ABANDONMENT OF EXISTING STORM SEWER FACILITIES... 6 305
More informationSTATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 811 CONDUIT AND DRAINAGE STRUCTURES
STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 811 CONDUIT AND DRAINAGE STRUCTURES January 18, 2013 811.01 Conduit Description 811.02 Conduit Materials 811.03 Conduit Definitions
More informationSANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.
SANITARY SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Sanitary Sewer Gravity Mains B. Sanitary Sewer Force Mains C. Sanitary Sewer Services 1.02 DESCRIPTION OF WORK A. Construct sanitary sewer gravity
More informationDIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM
DIVISION 22 PLUMBING PART 1 GENERAL 1.01 DESCRIPTION A. Provide a complete system of soil, waste, and vent piping to fixtures and equipment, including traps, floor drains and cleanouts, extending to a
More informationFOX METRO WATER RECLAMATION DISTRICT MANHOLE / SEWER PIPE MATERIALS AND INSTALLATION SPECIFICATIONS MATERIALS 1. PIPE & FITTINGS
FOX METRO WATER RECLAMATION DISTRICT MANHOLE / SEWER PIPE MATERIALS AND INSTALLATION SPECIFICATIONS MATERIALS 1. PIPE & FITTINGS Rev: 3/26/18 Pipe and fittings used in sanitary sewer construction shall
More informationConstruction works for Establishment of School in Al-Najaf M 2 2,600 M 2 750
1 Preparation of a 18-Classroom School BoQ for constructing a 18-Classroom School - Najaf Site Preparation:Works for leveling the site and remove the garbage to authorized location according to supervisor
More informationContact the Jurisdictional Engineer for materials allowed by each jurisdiction.
Design Manual Chapter 3 - Sanitary Sewers 3C - Facility Design 3C-1 Facility Design A. Capacity of Pipe Pipe sizes 15 inches and smaller should carry the peak flow at a depth of no more than 0.67 of the
More informationList of products of harmonised standards Code 28: PIPES-TANKS AND ANCILLARIES NOT IN CONTACT WITH WATER INTENDED FOR HUMAN CONSUMPTION
List of products of harmonised standards Code 28: PIPES-TANKS AND ANCILLARIES NOT IN CONTACT WITH WATER INTENDED FOR HUMAN CONSUMPTION EN 295-1 Part 1: Requirements for pipes, fittings and joints Vitrified
More informationSV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.
Wastewater Sampling Port Technical Data Submittal Special Precautions Specifications Installation 16½" (31.8 (41.9 cm) 8" (20.3 cm) -L -O SUBMITTAL STANDARD: 4" plain end inlet/outlet Highway traffic load
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping
SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of
More informationInflow pipe. Drain. Drain
Inflow pipe Screened overflow Drain Foul flush diverter Screened intake Manhole cover Maximum water level Seal Inspection cover Possible local drainage through screen Drain Bottom sloped Screened outlet
More informationConstruction works for Establishment of School in Al-Latifiyah. Al-Latifiyah BoQ for constructing a 6-pre-fab Classroom School
1 Al-Latifiyah BoQ for constructing a 6-pre-fab Classroom School Preparation of a 6-Classroom School Site Preparation:Works for leveling the site and remove the garbage to authorized location according
More informationTHE ADVANTAGES HDPE MANHOLES
NIC HDPE manholes are custom fabricated for many varied applications including municipal and industrial manholes, sewer and storm water manholes, leach ate collection, sewer lift stations, siphon structures,
More information1 Revised: 2019 Edition
STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm Sewers B. Abandonment of Storm Sewers 1.02 DESCRIPTION OF WORK A. Construct storm sewers. B. Abandon storm sewers. 1.03 SUBMITTALS Comply with
More informationDaytona Beach Pier Building Renovation Jun 2010
SECTION 15150 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationSUNY Genesee Community College JMZ Project No Implementation of Master Plan Projects - Phase 1 Site Improvements
PART 1 - GENERAL 1.01 SUMMARY SECTION 334100 STORM UTILITY DRAINAGE PIPING A. Section Includes: 1. Pipe and fittings. 2. Nonpressure transition couplings. 3. Expansion joints and deflection fittings. 4.
More informationA. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa).
SECTION 221313 - FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More information