AIR INTAKE VENTS. Special air intake Models for
|
|
- Egbert Wiggins
- 6 years ago
- Views:
Transcription
1 Special air intake Models for AIR INTAKE VENTS Model VMAX-AT DF Slopes : 4/12 to 15/12 Model VMAX-AT1-895-DF Slopes : 4/12 to 15/12 : air intake vent with storm proof baffle & shield that can be installed throughout strategic areas of the roof surface. AT DF NFA : 90 in. 2 AT1-895-DF NFA : 40 in. 2 Model VMAX-AT L / 1836-L Slopes: 3/12 to 8/12 Model VMAX-AT S / 1836-S Slopes: 9/12 to 15/12 : rectangular fresh air intake vent with storm proof baffle which is installed over the eaves of the roof. AT L / 1224-S NFA : 144 in. 2 SHIELD : optional AT L / 1836-S NFA : 324 in. 2 SHIELD : optional Model VMAX-AT L / 1836-L Slopes: 3/12 to 8/12 Model VMAX-AT S / 1836-S Slopes: 9/12 to 15/12 : triangular fresh air intake vent with storm proof baffle which is installed over the eaves of the roof. AT L / 1224-S NFA : 72 in. 2 AT L / 1836-S NFA : 162 in. 2 : Various types of fresh air intake vents to solve issues with attic ventilation and moisture condensation. Available Colours : Black, brown and grey. Model VMAX Mansard Soffit : two in one, allows fresh air into the attic at the junction and replaces the mansard flashing drip edge normally required at this junction. Gauge: 24 Length : 8 ft. NFA : in. 2 Model VMAX Storm Proof Soffit : designed to prevent weather infiltration through the soffits while still allowing for efficient fresh air intake. Length : 96 in. Width : variable 4 in. to 28 in. NFA for 1/2 in. : 39 in. 2 NFA for 3/4 in. : 58 in. 2 NFA for 1 in. : 78 in. 2 The opening is protected from intrusion by a galvanized wire mesh screen of 1/4 in. Model VMAX 50% Soffit : allows ten (10) times more fresh air intake than regular soffits. Available colour : White Length : 48 in. Width : 8 in. NFA : 164 in. 2 Model VMAX AE-Vent : unique storm proof wall mount air intake vent engineered and designed to prevent all weather infiltrations while allowing for efficient fresh air intake for attic air circulation for buildings designed without soffit vents. Costumed made to your specifications.
2 Roof exhaust trap Special air intake MODEL VMAX-AT1-895-DF SLOPE ROOF AIR INTAKE The VMAX-AT1-895-DF is a unique air intake vent designed and engineered specifically for buildings required to follow fire code regulations preventing the use of fresh air intake at the underside of the eaves, or built-in firewalls within the attic, due to risk of fire propagation, especially on row homes, being so close to one another. It is also used in situations where soffits are non- existent or non-functional. The concept of this intake vent allows the end user to install them at strategic areas throughout the roof, introducing fresh air directly into the attic space from the roof for attic air circulation in combination with the Maximum roof ventilators. The unique storm proof system prevents weather infiltrations while still allowing fresh air intake, thus, preventing heat build-up and moisture condensation which will lead to premature wear of the building and its components. A most effective and efficient product that will save the homeowner time, money and give final peace of mind. Specifications & Features A limited selection of special colours are available at a small premium. Model : VMAX-AT1-895-DF Profile : Rectangular Net Free Air : 40 in. 2 Roof Pitch : 4/12 to 15/12 Storm Proof : Unique precision engineered storm proof system Solid : Structural quality galvanized steel Standard Gauge : 24 & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown and grey Compliances : CSA, CAN-3-A930M82, ASTM-527
3 Roof Special exhaust air intake trap DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on slope roof recommendations for additional information and positioning. C A B D CODE # Height (A) Width (B) Total length (C) Height (D) NFA 25 in. AT1-895-DF 9 in. 8 in in. 40 in. 2 flange 3 in m. 2 flange Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.
4 Special air intake MODEL VMAX-AT DF SLOPE ROOF AIR INTAKE The VMAX-AT DF is a unique air intake vent designed and engineered specifically for buildings required to follow fire code regulations preventing the use of fresh air intake at the underside of the eaves, or built-in firewalls within the attic, due to risk of fire propagation, especially on row homes, being so close to one another. It is also used in situations where soffits are non- existent or non-functional. The concept of this intake vent allows the end user to install them at strategic areas throughout the roof, introducing fresh air directly into the attic space from the roof for attic air circulation in combination with the Maximum roof ventilators. The unique storm proof system prevents weather infiltrations while still allowing fresh air intake, thus, preventing heat build-up and moisture condensation which will lead to premature wear of the building and its components. A most effective and efficient product that will save the homeowner time, money and give final peace of mind. Specifications & Features A limited selection of special colours are available at a small premium. Model : VMAX-AT DF Profile : Rectangular Net Free Air : 90 in. 2 Roof Pitch : 4/12 to 15/12 Storm Proof : Unique precision engineered storm proof system Solid : Structural quality galvanized steel Standard Gauge : 24 & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown and grey Compliances : CSA, CAN-3-A930M82, ASTM-527
5 Special air intake DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on slope roof recommendations for additional information and positioning. C A B D CODE # Height (A) Width (B) Total length (C) Height (D) NFA AT DF 13 in. 12 in. 32 in. flange 3 in. 15 in. 90 in flange m. 2 Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.
6 Roof exhaust trap Special air intake MODEL VMAX-AT L/S SLOPE ROOF AIR INTAKE The VMAX-AT L & AT S are unique rectangular air intake vents designed and engineered for buildings with limited or non-existent soffits and for situations where the structural components including firewalls are obstructing the fresh air intake for attic air circulation. These models are installed directly on top of the roof over the eaves (overhang), even (flush) with the facias. The fresh air enters directly into the attic space from the roof to allow for attic air circulation in combination with the Maximum roof ventilators. The unique storm proof system will prevent weather infiltrations while still allowing fresh air intake, thus, preventing heat build-up and moisture condensation which can lead to the premature wear of the building and its components. Most effective and efficient product that will save the homeowner time, money, and give final peace of mind Note: these models are available in two different dimensions and slope variables, please view specifications and chart on the following page. Specifications & Features A limited selection of special colours are available at a small premium. Model : VMAX-AT L & AT S Profile : Rectangular Net Free Air : 144 in. 2 Roof Pitch VMAX-AT L : 3/12 to 8/12 Roof Pitch VMAX-AT S : 9/12 to 15/12 Storm Proof : Unique precision engineered storm proof system Solid : Structural quality galvanized steel Standard Gauge : 24 & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown and grey Compliances : CSA, CAN-3-A930M82, ASTM-527
7 Roof Special exhaust air intake trap DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on slope roof recommendations for additional information and positioning. C A B CODE # Height (A) Width (B) Total Length with flange (C) NFA AT S 12 in. 24 in in. (flange 4 in.) 144 in (flange 102) m. 2 AT L 12 in. 24 in. 46 in. (flange 4 in.) 144 in (flange 102) m. 2 Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.
8 Roof exhaust trap Special air intake MODEL VMAX-AT L/S SLOPE ROOF AIR INTAKE The VMAX-AT L & AT S are unique rectangular air intake vents designed and engineered for buildings with limited or non- existent soffits, and situations where the structural components, including firewalls, are obstructing the fresh air intake for attic air circulation. These models are installed directly on top of the roof over the eaves (overhang), even (flush) with the facias. The fresh air intake enters directly into the attic space from the roof to allow for attic air circulation in combination with the Maximum roof ventilators. The unique storm proof system will prevent weather infiltrations while still allowing fresh air intake, thus, preventing heat build- up and moisture condensation which can lead to the premature wear of the building and its components. Most effective and efficient product that will save the homeowner time, money and give final peace of mind Note: these models are available in two different dimensions and slope variables, please view specifications and chart on the following page. Specifications & Features A limited selection of special colours are available at a small premium. Model : VMAX-AT L & AT S Profile : Rectangular Net Free Air : 324 in. 2 Roof Pitch VMAX-AT L : 3/12 to 8/12 Roof Pitch VMAX-AT S : 9/12 to 15/12 Storm Proof : Unique precision engineered storm proof system Optional : Storm proof deflector for severe snow drifts Solid : Structural quality galvanized steel Standard Gauge : 24 & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown and grey Compliances : CSA, CAN-3-A930M82, ASTM-527
9 Roof Special exhaust air intake trap DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on slope roof recommendations for additional information and positioning. C A B CODE # Height (A) Width (B) Total Length with flange (C) NFA AT S 18 in. 36 in. 36 in. (flange 4 in.) 324 in (flange 102) m. 2 AT L 18 in. 36 in. 43 in. (flange 4 in.) 324 in (flange 102) m. 2 * NFA : Net free air Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.
10 Roof exhaust trap Special air intake MODEL VMAX-AT L/S SLOPE ROOF AIR INTAKE The VMAX-AT L & AT S are unique triangular air intake vents designed and engineered for buildings with limited or non existent soffits, and for situations where the structural components, including firewalls, are obstructing the fresh air intake for attic air circulation. These models are installed directly on top of the roof over the eaves (overhang), even (flush) with the facias. The fresh air intake enters directly into the attic space from the roof to allow for attic air circulation in combination with the Maximum roof ventilators. The unique storm proof system will prevent weather infiltrations while still allowing fresh air intake, thus, preventing heat build- up and moisture condensation which can lead to the premature wear of the building and its components. Most effective and efficient product that will save the homeowner time, money and give final peace of mind Note: these models are available in two different dimensions and slope variables, please view specifications and chart below. Specifications & Features A limited selection of special colours are available at a small premium. Model : VMAX-AT L & AT S Profile : Triangular Net Free Air : 72 in. 2 Roof Pitch VMAX-AT L : 3/12 to 8/12 Roof Pitch VMAX-AT S : 9/12 to 15/12 Storm Proof : Unique precision engineered storm proof system Solid : Structural quality galvanized steel Standard Gauge : 24 & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown and grey Compliances : CSA, CAN-3-A930M82, ASTM-527
11 Special Roof exhaust air intake trap DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on slope roof recommendations for additional information and positioning. A C B CODE # Height (A) Width (B) Total Length with flange (C) NFA AT S 12 in. 24 in in. (flange 4 in.) 72 in (flange 102) 0.05 m. 2 AT L 12 in. 24 in. 44 in. (flange 4 in.) 72 in (flange 102) 0.05 m. 2 * NFA : Net free air Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.
12 Roof exhaust trap Special air intake MODEL VMAX-AT L/S SLOPE ROOF AIR INTAKE The VMAX AT L & AT S are unique triangular air intake vents designed and engineered for buildings with limited or non existent soffits, and for situations where the structural components, including firewalls, are obstructing the fresh air intake for attic air circulation. These models are installed directly on top of the roof over the eaves (overhang), even (flush) with the facias. The fresh air intake enters directly into the attic space from the roof to allow for attic air circulation in combination with the Maximum roof ventilators. The unique storm proof system will prevent weather infiltrations while still allowing fresh air intake, thus, preventing heat build- up and moisture condensation which can lead to the premature wear of the building and its components. Most effective and efficient product that will save the homeowner time, money and give final peace of mind Note: these models are available in two different dimensions and slope variables, please view specifications and chart on the following page. Specifications & Features A limited selection of special colours are available at a small premium. Model : VMAX-AT L & AT S Profile : Triangular Net Free Air : 162 in. 2 Roof Pitch VMAX-AT L : 3/12 to 8/12 Roof Pitch VMAX-AT S : 9/12 to 15/12 Storm Proof : Unique precision engineered storm proof system Solid : Structural quality galvanized steel Standard Gauge : 24 & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown and grey Compliances : CSA, CAN-3-A930M82, ASTM-527
13 Roof Special exhaust air intake trap DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on slope roof recommendations for additional information and positioning. C A B CODE # Total Length Height (A) Width (B) NFA with flange (C) AT S 18 in. 36 in. 36 in. (flange 4 in.) 162 in (flange 102) m. 2 AT L 18 in. 36 in in. (flange 4 in.) 162 in (flange 102) m. 2 Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.
14 Roof exhaust trap Special air intake MODEL VMAX mansard soffit drip edge The VMAX Mansard Soffit Drip Edge has been developed and deigned to allow for fresh air intake directly into the attic space at the junction or transition of the mansard and eave of the slope roof where you would normally install a drip edge. Two products in one, this product is an effective and efficient way to ensure proper ventilation and prevent heat build-up and moisture condensation which can lead to the premature wear of the building and its components. An innovative product that will save homeowners time, money and final peace of mind. Specifications & Features A limited selection of special colours are available at a small premium. Model : VMAX Mansard Soffit Drip Edge Net Free Air : in. 2 Length : 8 ft. including 2 in. overlap End caps : Required to close off extremities Roof Pitch : Costumed to your specifications Solid : Structural quality galvanized steel Standard Gauge : 24 Rodent Proof : Built-in 1/8 in. (3.175 mm) galvanized wire mesh screen Finish : Powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown and grey Compliances : CSA, CAN-3-A930M82, ASTM-527
15 Roof Special exhaust air intake trap DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on slope roof recommendations for additional information and positioning. On roof deck A Opening in mansard roof F Screen in soldered galvanized steel C D E Air-Intake opening B Mansard CODE # Lenght A B C D E F (screen) NFA SM-SELECT Mansard Soffit Drip Edge 8 ft. 6 in. 3 in. 2.5 in in. 1.5 in. 2.5 in in m m. 2 SM-BOU End caps, (needed to close extremities) * NFA : Net free air Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.
16 Roof exhaust trap Special air intake MODEL VMAX storm proof soffit The VMAX Storm Proof Soffit is a unique soffit that has been designed and engineered for fresh air intake for attic air circulation and to prevent all weather infiltrations into the attic space, even in high gust of wind. A bonus feature to this product is its steel construction that prevents all rodents, including raccoons, from gaining access into the attic space. Specifications & Features A limited selection of special colours are available at a small premium. Model : VMAX Storm Proof Soffit Width : Costumed from 4 in. to 28 in. (on demand) Length : 8 ft. including 2 in. overlap Thickness : Variable from 1 in. to 2 in. Net Free Air for 1/2 in. opening : 39 in. 2 per length Net Free Air for 3/4 in. opening : 58 in. 2 per length Net Free Air for 1 in. opening : 78 in. 2 per length Standard Gauge : 24 & 26 Rodent Proof : Built-in 1/4 in. (6.35 mm) galvanized wire mesh screen Finish : Pre-painted steel Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : All available pre-painted galvanized steel
17 Roof Special exhaust air intake trap DIMENSIONS AND SPECIAL CHARACTERISTICS Dimensions of the openings % of opening of the screen Total air entrance for 8 ft. section 0.5 in. 81 % 39 in mm m in. 81 % 58 in. 2 Variable 19 mm. 1 in. 81 % 0.04 m in. 2 Stormproof grill 25 mm m. 2 J Molding Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.
18 Roof exhaust trap Special air intake MODEL VMAX 50% Soffit The VMAX 50% Soffit is a unique soffit vent developed to permit considerable quantity of fresh air intake for the improvement of the attic ventilation. Developed for those buildings when the existing soffits are not performing as expected due to their net free air specification, restrictive width or length of the soffit overhang, or again when you need to balance air flow on buildings with different length of roof slopes. They are frequently used as an efficient, yet, economical way of replacing existing soffits that were installed over wood, at strategic areas, thus allowing savings for the end user. A product with multiple uses that offers the end user an effective and economical solution for a final peace of mind. Specifications & Features A limited selection of special colours are available at a small premium. Model : VMAX 50% Soffit Width : 8 in. Length : 48 in. Perforation : in. Net free air : 164 in 2. Material : Aluminium Finish : Powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : White
19 Roof Special exhaust air intake trap DIMENSIONS AND SPECIAL CHARACTERISTICS PROFIL A D 1/2 soffit 50% maximum B C 1/2 standard soffit CODE # A B C D PERFORATION NFA VMAX 50% soffit 7 in. 8 in. 4 ft. 0.5 in in. 164 in m m. 2 Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.
20 Special air intake MODEL VMAX AE Vent The VMAX-Storm Proof Wall Vent is a unique air intake vent designed and engineered specifically for buildings with limited, nonfunctional, or non- existent soffits for the fresh air intake required by code for attic air ventilation. This unique design allows the end user an alternative for fresh air intake through the walls without compromising the integrity of the building within. Completely storm proof, it is built of galvanized structural steel and a unique built-in storm proof protection diverter pan preventing all weather infiltrations, even in high gust of winds. This latest new addition to Maximums collection of innovative products offers definitive flexibility and solutions for engineers, architects, designers, and building owners. Specifications & Features A limited selection of special colours are available at a small premium. Model : VMAX-AE-Vent Profiles : Square, rectangular, triangular Sizes : Costumed made to your requirements and specifications Storm Proof : Unique precision engineered protection diverter pan Solid : Highest quality galvanized structural steel Standard Gauge : 24 Rodent Proof : Built-in galvanized wire mesh screen Finish : Powder coated polyester baked paint with UV protection Warranty : Limited Lifetime warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown, grey and white
21 Special air intake DIMENSIONS AND SPECIAL CHARACTERISTICS Protection pan Sizes costumed made to your requirements and specifications. Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.
ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION
ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION RUSKIN sand trap louvers are specially designed to separated the sand and dust from the air. It is effective and necessary to apply for ventilations and inlet
More information1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500
07721 ROOF ASSEMBLY SUPPORTS FOR ROOFTOP EQUIPMENT ****************************************** SPECIFIER: All roof-related items above or outside the structural roof deck, including such work as blocking,
More informationSiding and Soffit Installation Guidelines
Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field
More informationINSTALLATION GUIDE.
INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Canyon Shake counter batten
More informationEffective Date: Jan. 1, 2016 DURAFLO SECTION ROOF VENTS WE KNOW VENTILATION
Effective Date: Jan. 1, 2016 DURAFLO SECTION 077200 ROOF VENTS WE KNOW VENTILATION Extreme weather conditions across the country has increased the demand for a weather resistant vent. Duraflo has developed
More informationALLMET CONTINENTAL INSTALLATION GUIDE
ALLMET CONTINENTAL INSTALLATION GUIDE www.allmet.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Allmet Continental
More informationLouvers Selection, Design Considerations and Details Written by Matt Trentham, R.L. Craig Company, Inc.
Louvers Selection, Design Considerations and Details Written by Matt Trentham, R.L. Craig Company, Inc. Louvers are a basic and simple part of many HVAC systems and buildings, but they are often overlooked
More informationMETAL ROOFING: RE-ROOFING QUESTIONS & ANSWERS
METAL ROOFING: RE-ROOFING QUESTIONS & ANSWERS Building contractors are always looking for installation methods that will provide them with savings on labor and materials expenses. Here are some important
More informationPacific Tile Counter Batten and Batten
Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationCS-100 Guide Specifications
MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification
More informationMILLENNIUM METALS, INC TEST REPORT
MILLENNIUM METALS, INC TEST REPORT SCOPE OF WORK WIND DRIVEN RAIN RESISTANCE TESTING OF MMI 26 GA OFF RIDGE VENT WITH DETACHABLE BAFFLE REPORT NUMBER H7685.03-450-18 R1 TEST DATE 11/29/17 ISSUE DATE 12/18/17
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION SECTION 07320 TWO-PIECE TAPERED MISSION CLAY ROOFING TILE PART 1 GENERAL 1.01 SECTION INCLUDES A. Formed clay roofing tiles, complete with components and other required accessories
More informationICC-ES Report OR-4, AND MOISTURE DIVISION: SECTION: SECTION: Reissued 11/2017 This. Report Holder:
ICC-ES Report ESR-3482 Reissued 11/2017 This report is subject to renewal 11/2018. EVALUATION SUBJECT: LO-OMNIROLL LOR-30, LO-OMNIRIDGE LOR9-4, OMNIRIDGE OR-4, TILERIDGE TRV-4, TILEINTAKE IV-9 AND DECK-AIR
More informationESJ-401RM. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)
Stationary Louver J Blade Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates J style blades, sloped sill and
More informationSapphire Metal Tile Roofing System
Sapphire Metal Tile Roofing System Sapphire Metal Tile Roofing Benefits of Sapphire Metal Tile - Beauty and function - Tile Beauty, Steel Strength, Lasts a lifetime - Excellent long term investment - Pays
More informationESD-635. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Stationary Louver Drainable Blade is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates drain gutters in the head
More informationEDK-402. Stationary Louver K Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Stationary Louver K Blade is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates drainable head, K style blades,
More informationSECTION TURBINE VENTILATORS
SECTION 07 72 00 TURBINE VENTILATORS **This is a CSI Three-Part Specification using CSI MasterFormat 2004-2010 Section Numbers and Titles. This specification must be edited to suit your particular project.
More informationGeneral Overview SECTION PBR & R PANEL - PREFORMED ROOF AND WALL PANELS
SECTION 07410 - PREFORMED ROOF AND WALL PANELS # Specifier: Notation (#) means that text following is a specifier s note or sample. PART 1 - GENERAL 1.01 Description # Specifier: Do not alter paragraph
More informationLight-Metal Roof Edge, Raised
NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED
More informationSTAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
More informationThermaCal Nail Base Roof Insulation Panels (all versions) Installation Instructions
ThermaCal Nail Base Roof Insulation Panels (all versions) Installation Instructions PRODUCTS a. ThermaCal 1 Ventilating Roof Insulation Panel is a venting nailable composite roof insulation panel with
More informationEHH-201. Wind-Driven Rain Louver Horizontal Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design is a Wind-Driven Rain louver designed to protect air intake and exhaust openings in building exterior walls that are sensitive to direct water penetration. Design incorporates a
More informationESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes
Application and Design Florida Product Approved Drainable Blade Louver is a Florida Product Approved stationary drainable blade extruded aluminum louver designed to protect air intake and exhaust openings
More informationSED-501. Sightproof Louver Drainable Blade. Application and Design
Application and Design is a sightproof weather louver designed to protect air intake and exhaust openings in building exterior walls when visual see through prevention is needed. Design incorporates a
More informationLOUVER PRODUCTS. Architectural Blade Louvers Drainable Blade Louvers Wind-Driven Rain Louvers Sightproof Louvers Acoustical Louvers Thinline Louvers
LOUVER PRODUCTS Archives of Ontario Building, York University, Toronto, Ontario Architectural Blade Louvers Drainable Blade Louvers Wind-Driven Rain Louvers Sightproof Louvers Acoustical Louvers Thinline
More informationESD-403. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Stationary Louver Drainable Blade is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member
More informationEXTEND THE BEAUTY OF YOUR HOME
EXTEND THE BEAUTY OF YOUR HOME ADDED BEAUTY & FREEDOM FROM MAINTENANCE THE CHOICES YOU NEED FOR THE LOOK YOU WANT DOUBLE 5 PREMIUM.048" Panel thickness, provides superior rigidity over most soffit panels
More informationLittlies. Willplay s Littlies range offers floor. Cool activities for little kids!
Littlies Cool activities for little kids! Willplay s Littlies range offers floor based activities that promote safe play while challenging the little ones imaginations. From cubby houses to interactive
More informationINSTALLATION MANUAL Heritage Series
INSTALLATION MANUAL Heritage Series STEEL ROOF PANELS HEAD OFFICE 1418 Michael St., Ottawa, ON K1B 3R2 WATS LINE: 1 800-267-0860 TEL.: 1 613-746-3206 FAX: 1 613-746-0445 Contents Page Introduction, Storage..
More informationroof tiles The safest option Practical and easy to install
S-INTERLOCKING roof tiles The safest option Practical and easy to install We offer three formats that combine curved profiles. Thanks to more advanced production processes and the quality of clay used
More informationEziform Ridge Vent Natural Roof Ventilators
Eziform Ridge Vent Natural Roof Ventilators 1 Eziform Ridge Vent Natural Roof Ventilators Eziform Ridge Vents from Eziform Sheet Metal provide an economical, effective and low maintenance method of exhausting
More informationEDD-601. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction
Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to
More informationBrava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:
Brava Spanish Tile Installation Manual Brava Roof Tile Phone: 319-338-5706 Fax: 319-343-1038 www.bravarooftile.com This document includes the recommended and suggested installation procedures for Brava
More informationEACA-601D. Miami-Dade Qualified Combination Louver
Miami-Dade Qualified Combination Louver Application and Design is a Florida Product Approved and Miami-Dade Qualified combination louver/damper designed to protect air intake and exhaust openings in building
More informationSECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM
SECTION 13 34 21 - STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. The structural retrofit roof sub-framing system will provide support for a new metal roofing system constructed
More informationALUMINUM SIDING SOFFITS, MOULDINGS AND ACCESSORIES
ALUMINUM SIDING, MOULDINGS AND WWW.DUCHESNE.CA DUCHESNE ALUMINUM SIDING AND COMBINE QUALITY, PRACTICALITY AND GOOD LOOKS. THE PERFECT COMPLEMENT TO VINYL SIDING AND STEEL ROOFING AND SIDING Wide selection
More informationEVERLAST KWILA/MERBAU GL17S ENGINEERED MAGNA BEAMS & KWILA/MERBAU GL13 ENGINEERED MAGNA POSTS
Version 1 EVERLAST KWILA/MERBAU GL17S ENGINEERED MAGNA BEAMS & KWILA/MERBAU GL13 ENGINEERED MAGNA POSTS DRAFT SAFE LOAD TABLES MARCH 2012 Page 0 Page 1 Contents Introduction Page 3 Engineering Certification
More informationPREFA Aluminiumprodukte GmbH Page 1 of 21
Tender Specifications 120901 PREFA Shingles_2012 ---------------------------------------------------------------------------------- 01. Text GENERAL PRELIMINARY REMARKS Roof ----------------------------------------------------------------------------------
More informationTEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up
TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM Form 15 Work Write-Up Owner-Builder Applicant Owner-Builder Co-Applicant Physical Address: City,
More informationWILDLAND URBAN INTERFACE (WUI) PRODUCTS
CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL WILDLAND URBAN INTERFACE (WUI) PRODUCTS Published by CAL-FIRE WILDLAND FIRE PREVENTION ENGINEERING Revised 12/17/07
More informationSECTION HVAC GRAVITY VENTILATORS
SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSteelwork and Security Kiosks
Steelwork and Security Kiosks Staircases, Fire Escapes and Ladders 282 Handrails and Guardrails 283 Platforms and Flooring 284 Fencing 285 Kiosks 286 Cages 287 Bar Sets and Grilles 288 Ancillary Items
More informationREPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2134 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 07 00
More informationStanding Seam Systems. NBS Specification. KingZip SF Standing Seam Roofing System
NBS Specification KingZip SF Standing Seam Roofing System H31 METAL PROFILED/FLAT SHEET CLADDING/COVERING To be read with Preliminaries/General conditions. TYPE OF CLADDING SYSTEM 140 METAL PROFILED CLADDING
More informationNouveau BBQ Single Flue
Nouveau BBQ 900-1100-1250-1500 Single Flue Outdoor BBQ Cooking Fire Wood Burner Installation Instructions FLUE SYSTEMS Casing. Flue system may require to be doubled lined to comply. Ref ASNZS:2918:2001
More informationFiber Cement Collection. AlluraUSA.com
Fiber Cement Collection The ultimate building material allternative. Unlike wood, vinyl and other traditional building materials, Allura Fiber Cement products will resist damage from hail or termite attacks,
More informationCustom Canopies Intl. Inc.
POWDERCOAT COLORS WHITE GREY ALMOND GREEN TEAL POWDER BLUE YELLOW RED ORANGE BLACK BROWN BLUE STANDARD SHADE SAIL & SHADE STRUCTURE SPECIFICATIONS Quality Assurance All shade structures & shade sails shall
More informationSECTION ROOF SPECIALTIES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationSECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM
PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.
More informationSpecifications for FL-100 Soffit Panel
Union Corrugating Company Specifications for FL-100 Soffit Panel SECTION 07410 METAL SOFFIT PANELS PART 1 GENERAL 1.1 DESCRIPTON A. Section Includes: 1. Preformed metal soffit panel system 2. Associated
More informationSteelwork and Security Kiosks
Steelwork and Security Kiosks Staircases, Fire Escapes and Ladders 282 Handrails and Guardrails 283 Platforms and Flooring 284 Fencing 285 Kiosks 286 Cages 287 Bar Sets and Grilles 288 Ancillary Items
More informationSLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]
[Change these specifications as needed. Use this sample proposal at your own risk. This is a simple, general proposal and is not meant to be a comprehensive proposal for all situations or projects. If
More informationCentral Texas Metal Roofing Supply Co., Inc 36" NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼
36" 1 2 " 6" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 26 26 26 24 24 24 24 TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD CHANNEL GUARD CHANNEL GUARD GALVALUME
More informationEAD-635. Adjustable Louver Drainable Blades. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Adjustable Louver Drainable Blades is an adjustable louver designed to protect air intake and exhaust openings in building exterior walls that require tight air shut off. Design
More informationCan be installed. sloped roofs. on all. toutes les toitures. S adapte à 18 / 12 56º. 2/12 to 18/12. from
2 / 12 9º S adapte à toutes les toitures en pentes allant de 2/12 à 18/12 4 / 12 18º Les ventilateurs Optimum sont conformes aux normes CSA. Optimum s Hattic Ventilator are conform to CSA norms. 8 / 12
More informationWestern States 7/8 Corrugated
Western States 7/8 Corrugated Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key
More informationESF-145. Thin-line Louver Flat Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Flat Blade is a thin-line stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth makes
More informationAPPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET
Environmental Protection and Growth Management Department BUILDING CODE SERVICES DIVISION 1 N. University Drive, Box #302 Plantation, Florida 33324 954-765-4400 Broward.org/Building APPLICATION INFORMATION
More informationSECTION COMPOSITE ROOF TILE SYSTEMS
SECTION 07 30 00 COMPOSITE ROOF TILE SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Roof underlayment. B. Composite slate roofing. C. Composite shake roofing. D. Ventilation. E. Fasteners. F. Metal flashing.
More informationDyno Test Rooms Professional Chassis, Engine & Specialty Test Rooms for the PowerSports & Product Testing Market
INC s Professional Chassis, Engine & Specialty Test Rooms for the PowerSports & Product Testing Market Proven performance Contains noise and removes exhaust Rugged modular steel panel construction Safe
More informationPREFA Aluminiumprodukte GmbH Page 1 of 25
Tender Specifications 120901 PREFALZ Double Standing Seam_2012 ---------------------------------------------------------------------------------- 01. Text GENERAL PRELIMINARY REMARKS Roof ----------------------------------------------------------------------------------
More informationInstallation Instructions
Installation Instructions SAVE THESE INSTRUCTIONS Please read this entire manual before you install and use your room heater. Failure to follow instructions may result in property damage, bodily injury,
More informationINTERIOR ENVIRONMENT
CHAPTER 12 INTERIOR ENVIRONMENT > SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions,
More informationBuilt to Last a Lifetime
Built to Last a Lifetime Welcome to Lincoln 2 This brochure will introduce you to Lincoln Steel Buildings from the ground up starting with the framing of the building all the way to the roof and finally
More informationEACC-601. Combination Louver/Damper Concealed Actuator. Application and Design. Standard Construction
Application and Design Concealed Actuator is a combination louver/damper designed to protect air intake and exhaust openings in building exterior walls that, at times, require tight air shut off. Design
More informationFinestone Stucco Ultra Wall System
Finestone Stucco Ultra Wall System Premium impact and puncture resistant, rain screen design cement plaster stucco system with enhanced water management Typical Details BLANK PAGE Finestone Stucco Ultra
More informationFORMDECK. constructions. constructions
FORMDECK constructions constructions Introduction Formdeck300 (FD300) is a very efficient and durable permanent metal tray formwork, reinforcement and ceiling system used for suspended concrete slab construction.
More informationESU-150. Thin-line Louver Thin-line Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Thin-line Blade is a thin-line stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth
More informationGUIDANCE DOCUMENT IGNITION RESISTANT EAVE CONSTRUCTION
GUIDANCE DOCUMENT IGNITION RESISTANT EAVE CONSTRUCTION Since the 1980s, the County s fire and building codes have been strengthened in successive code adoption cycles with the primary goal of protecting
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2664 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 07 00
More informationWeatherproofing & Sealing Systems
Weatherproofing & Sealing Systems Weather Barrier & Waterproofing Residential & Commercial Structures New Construction, Remodeling & Repair Low Slope Roofing Membranes Roofing Underlayments Window & Door
More informationJ41 Reinforced bitumen membrane roof coverings
J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. A comprehensive waterproofing system comprising two reinforced bituminous membranes fully adhered to thermal
More informationTC54. for architects & designers. Dimensions Clearances Venting
for architects & designers TC54 Series D Dimensions Clearances enting IMPORTANT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer to the Instruction
More informationCentral Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH
1 2 " 1 24" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 5 Vee GALVALUME 24 26 3/8 95.00 PRICE PER SQ. PRICE PER LINEAR FOOT PANEL PRICING: 1. Price per Square is based on 26 3/8 sheet
More informationCorium Brick Rainscreen System Specifications
CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated
More informationPioneer Forced Draft Cooling Tower Specifications
Delta Cooling Towers, Inc. 41 Pine Street P.O. Box 315 Rockaway, New Jersey 07866-0315 Telephone 973.586.2201 Fax 973.586.2243 www.deltacooling.com sales@deltacooling.com Pioneer Forced Draft Cooling Tower
More informationAppendix 4. Bills of Quantities
Appendix 4. Bills of Quantities 201 A4.1 Deep trench latrines Partitions of local materials 1m apart Timber foot rests and floor plates Lightweight timber frame Excavated soil (used for back-fill) Plastic
More informationPRODUCT RANGE OF GRILLES, DIFFUSERS, LOUVRES AND DAMPERS
Monodraught are the recognised market leaders in ultra-low carbon, low energy solutions for Natural Ventilation, Natural Cooling and Natural Lighting. WINDCATCHER, SUNPIPE and COOL-PHASE brands are synonymous
More informationSPECIFICATION GUIDELINE
Environmental StoneWorks specification guideline should be used to assist design professionals in the preparation of projects. Edit and delete items that may not be applicable. Verify all referenced section
More informationDIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.
DIVISION 04 MASONRY 04720 CAST STONE A. Design Considerations 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone. 2. Care must be taken in the design of individual units
More informationTRIAD CORRUGATED METAL, INC.
TRIAD CORRUGATED METAL, INC. C O M M E R C I A L R E S I D E N T I A L A G R I C U L T U R A L Snap Loc Panel Guide Snap Loc metal panels are a perfect fit for residential, architectural and commercial
More informationROOF ICE MELT RIM SYSTEM
ROOF ICE MELT RIM SYSTEM This design guide provides the information necessary to help our design engineers design your Raychem Roof Ice Melt (RIM) system. For other applications or for design assistance,
More informationSIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION
TORSION SPRING CEILING SYSTEM SPECIFICATION NOTICE: Consult your local Sound Concepts representative or contact Sound Concepts at 204.783.6297 before specifying any optional or custom element as shape,
More informationSpecifiers: Click on the icon in the WORD toolbar to reveal detailed instructions
Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated
More informationAgricultural METAL ROOFING
Agricultural METAL ROOFING Building Relationships Since 1908 American Building Components started its business by serving the agricultural consumer. Since 1908, we have worked side by side with our customers
More informationPREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and
PREP + INSULATION HOME ENERGY UPGRADES What every contractor needs to know. Copyright 2012 Advanced Energy. All Rights Reserved 103 HOME ENERGY UPGRADES Prep + Insulation Contents Air sealing is a challenging
More informationPERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960
STUC-O-FLEX PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary
More informationOS-ALD ACOUSTIC LOUVERS
OPTIMA Acoustic Louvers Overview OPTIMA Acoustic Louvers are designed to provide optimal acoustic performance (noise reduction) with minimal airflow restrictions. OS-ALD acoustic Louvers are typically
More informationCity of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017
City of Republic Community Development Department Residential Roofs REVISION DATE: JANUARY 2017 A residential roof permit is required for new roofs and for replacement roofs when the replacement area is
More informationDAN S CUSTOM SHEETMETAL Manufacturer and Distributor
About the Company DAN S CUSTOM SHEETMETAL Manufacturer and Distributor In 1993, DCSM was the first manufacture in the state of Florida to fabricate metal eave closure for tile. We have established a reputation
More informationby Rollfab Metal Products
by Rollfab Metal Products SECTION 07460 ALUMINUM SIDING AND SOFFITS PART 1 GENERAL 1.2 RELATED SECTIONS 1.3 REFERENCES A. SECTION INCLUDES B. Aluminum Siding. C. Aluminum Soffits. D. Aluminum trim and
More informationHOW TO FIGURE METAL ROOFING MATERIALS
HOW TO FIGURE METAL ROOFING MATERIALS 1. The first step in figuring your metal roofing is to make a sketch of it, complete with the roof measurements. Take the house below as an example: 52 R 12-8 P 19
More informationSECTION SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.
More informationSection SPHEROID ELEVATED WATER STORAGE TANK
Section 13210 SPHEROID ELEVATED WATER STORAGE TANK Note to Contract Specifier Specification clauses requiring revision or insert are highlighted and underlined. Specification notes are highlighted and
More informationRecommended installation procedures for Harvest and Beaumont Shake Note: Harvest Shake is 7 5/8 exposure and Beaumont Shake is 9 exposure
Page1 Recommended installation procedures for Harvest and Beaumont Shake Note: Harvest Shake is 7 5/8 exposure and Beaumont Shake is 9 exposure Do not begin installation until you have read and fully understand
More informationMANUFACTURING WITH INNOVATION In the UK since. Continuous Line Acoustic Louvres. caice.co.uk
MANUFACTURING WITH INNOVATION In the UK since 1993 Continuous Line Acoustic Louvres caice.co.uk Our new & exclusive Continuous Line Acoustic Louvre system The unique and modular design maintains a continuous
More informationSPECIFICATIONS DRAFT - MORCELLEMENT AT SOUILLAC
SPECIFICATIONS DRAFT - MORCELLEMENT AT SOUILLAC PLANNING CONTROLS Density No more than one house will be allowed per plot Plot coverage 45% maximum % Plot coverage = area of building on Ground Floor (including
More informationSpecifiers: Click on the icon in the WORD toolbar to reveal detailed instructions
Specifiers: Click on the icon in the WD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying metal wall panels
More informationCASSETTE BS Specification book
CASSETTE BS Specification book Edition: April 2011 ArcelorMittal Construction International Industriestrasse 19 8112 Otelfingen / Zürich Switzerland www.arcelormittal.com/arval PRESENTATION OF THE SYSTEM
More information