Lo-pitch. Insulated Panels. Low Pitched and Curved Insulated Roof System. Insulated Panels to the Power of CI/SfB.

Size: px
Start display at page:

Download "Lo-pitch. Insulated Panels. Low Pitched and Curved Insulated Roof System. Insulated Panels to the Power of CI/SfB."

Transcription

1 Insulated Panels CI/SfB (47) Nh2 March 2005 Lo-pitch Low Pitched and Curved Insulated Roof System Approved to LPS 1181 Certificate No s. Holywell 260a/13 Kingscourt 186a/05 Insulated Panels to the Power of Insurer Approved Systems

2 Superior specification and construction for roof slopes of 1.5 or curved roofs of 150m radius and above 2

3 Introduction 5 Market Sectors 6 Product Data 10 Model Specifications 16 Construction Details Panel Dimensions Detail 27 End Lap Detail 28 Ridge Detail 29 Eaves Detail Valley Gutter Detail 32 Verge Detail Curved Roof Panel 35 3

4 Introduction The low pitched roof system and the alternative to standing seam roof systems which provides guaranteed specification performance compliance and reliability for the overall life of the building. Kingspan KS1000 LP/CR insulated roof systems are available in steel and aluminium specifications and suitable for Lo-pitch, Curved and Architectural roofing applications. These roof cladding systems provide high performance construction solutions with a durability warranty package of up to 25 years to first maintenance with overall life expectancy of up to 40 years. The superior specification and long term installed reliability of KS1000 LP/CR roof systems provide building owners with a cost effective, low air leakage and high performance package which allows reduced M&E plant, energy operating costs and reduced CO2 emissions. Loss Prevention Council and Factory Mutual Approved Systems are available. Welded end laps specifications are available for plain aluminium systems which eliminate end laps. Approved to LPS 1181 Certificate No s. Holywell 260a/13 Kingscourt 186a/05 4

5 System Benefits Complies with HSE and CDM safety requirements. Lo-pitch roof minimum slope 1.5 degrees. Curved roof minimum radius 150 metres. Available in aluminium and steel. Lengths up to 28.5 metres - site welded end laps available with plain aluminium facings. Property & Business Risk Protection Loss Prevention Certification Board (LPCB) certified external cladding systems can be classified as non-combustible building by the Association of British Insurers (ABI). Fully complies with Part L2 (England & Wales) and Part J (Scotland) and Part L (Ireland) Regulations and Standards. Lifetime insulation continuity, thermal performance and airtightness (5m 3 /hr/m 2 ) certainty. Accelerated build speed through pre-engineered, single component, single-fix installation, reduces site time by up to 50%. Environmentally sustainable system Zero ODP and non-deleterious. Energy efficient performance reduces M&E plant and lifetime operating costs by up to 40%. Environmentally sustainable solutions reduce lifetime Carbon Dioxide (CO 2) emissions by up to 40%. Complies with Parts E & H Resistance to the passage of sound for non-domestic buildings. For residential, domestic, education and healthcare building applications, BB93 and HTM 2045 solutions, consult Kingspan Technical Design Bureau. Lifetime durability steel up to 25 years to first maintenance and overall life expectancy of up to 40 years. Lifetime durability aluminium up to 40 years to first maintenance and overall life expectancy of up to 60 years. Rooflight systems available. Can incorporate safety and fall arrest systems. Quality approved to IS0 9001:

6 Market Sectors Mamhilad COMMERCIAL COMMERCIAL Maynooth Business Park RETAIL Morrisons Shopping Centre Fairways Hotel, Dundalk LEISURE LEISURE Carlingford Marina 6

7 St Caddoc s School REFURBISHMENT St Caddoc s School REFURBISHMENT Castle Primary School EDUCATION Millfield College EDUCATION North Western Health Board HEALTHCARE HEALTHCARE North Western Health Board 7

8 Market Sectors Queens Towers, Holland RESIDENTIAL TECHNOLOGY Phototronics, Manchester ELECTRONICS LG Electronics, Newport Big Yellow LOGISTICS 8

9 LOGISTICS Morrisons Distribution INDUSTRIAL Parcel Force, Coventry 9

10 Product Data Application The KS1000 LP/CR Roof is a high specification system suitable for building applications for new build and refurbishment. i) roof slopes 1.5 and above after deflection. ii) curved roofs 150 metre radius and above. Product Reference KS1000 LP/CR-LPCB Approved to LPS 1181 Certificate No s. Holywell 260a/13 Kingscourt 186a/05 KS1000 LP-FM Application Description Lo-pitch & curved roof panel with Loss Prevention Certification Board (LPCB) approval for roof applications. Lo-pitch roof panel with Factory Mutual (FM) approval for roof applications. For KS1000 CR contact Kingspan Technical Design Bureau Dimensions & Weight Insurer Approved System 1000mm cover width A B A - Core Thickness (mm) * 100* B - Overall Dimension (mm) Weight kg/m 2 0.5/0.4 steel Weight kg/m /0.4 steel Weight kg/m 2 0.7/0.5 alum *These panel thicknesses comply with Part L2 (England & Wales) and Part J (Scotland) Aluminium faced panels are not LPCB and FM certified. 10

11 Product Tolerance Cut to Length -5mm +10mm Liner Sheet Length -5mm +10mm Cover Width -0mm +3mm Thickness -2mm +2mm End Square -3mm +3mm Available Lengths Panel lengths 1.8 to 28 metres are supplied. Panels less than 1.8m long can be supplied but do not have a cut back as standard and are subject to extra charge. Please contact our Quotations Hotline for full costs. Panel Length Panel End Cut Back Panels can be supplied with a cut back of 75mm or flush ends. Panels less than 1.8m long which require a cut back can be provided, but will be charged at full 1.8m price, plus cutting cost. Please contact our Quotations Hotline for full costs. End Lap It is recommended that panels are used in continuous lengths from ridge to eaves with no end laps. However, where an end lap must be used the flush end of the down slope panel has a factory fitted end lap stitching plate. Cover Cap The cover cap is made from 0.5mm thick steel coated to the same specification as the weather sheet of the panels. The caps are supplied in lengths up to 12 metres. Panels less than 1.8m long which require a cutback are subject to extra charge. 11

12 Product Data Materials - Steel Substrate HPS200/Celestia*: ZA255 Galvalloy hot-dip zinc-aluminium alloy coated steel (= 95% Zn/=5% Al) to BS EN : 1995, Grade Fe E220G with a Z275 zinc coating. PVDF*: Galvatite, hot-dipped zinc coated steel to BS EN : Grade Fe E220G with a Z275 zinc coating. Standard external sheet thickness 0.5mm, standard internal sheet thickness 0.4mm. Other thicknesses can be supplied to special order. Coatings - External Weather Sheet HPS200 Plastisol: Nominal 200 micron thick high performance coating applied to the weatherside of the panel. Designed to achieve high levels of durability and colour stability, is highly resistant to damage in transit and on-site. Celestia*: Nominal 120 micron thick Plastisol coating 16 metallic colours. Reverse side of sheet coated with a light grey polyester coating. The sheet is available in either plain or stucco embossed finish. Coatings - Internal Liner Sheet Lining Enamel: Nominal 15 micron thick coating developed for use for the internal lining of insulated panels. Standard colour is bright white with an easily cleaned surface. HPS200 Plastisol: Nominal 200 micron thick coating used in areas where there is high internal humidity, or a corrosive environment. Stelvetite Food & Hygiene Safe: This is a nominal 20 micron thick chemically inert polymer film bonded to steel suitable for cladding the interior of cold stores, food processing buildings and other hygiene applications. Reverse side of sheet coated with a light grey polyester coating. The sheet is available in either plain or stucco embossed finish. Materials - Aluminium Substrate Aluminium substrate, Grades 3003/4/5 series. Standard external sheet thickness 0.7mm, standard internal sheet thickness 0.5mm. Coatings - External Weather Sheet PVDF: Nominal 25 micron thick stoved fluorocarbon coating which has excellent colour stability even at temperatures as high as 120 C. ARS Abrasion Resistant: Nominal 28 micron thick polyester or polyurethane resin reinforced with polyamide high durability coating with exceptionally good handling characteristics. Silicone Polyester: An economical coating with medium term life for worldwide use. Alternatively the weather sheet can be supplied in mill finish, stucco embossed. Coatings - Internal Liner Sheet Standard internal facing is white polyester coated, plain or stucco embossed. Insulation Core Polyisocyanurate (PIR): with zero ozone depletion (Zero ODP). Available in LPCB and FM insurer approved certified product range. For KS1000 CR/FM please contact Kingspan Technical Design Bureau. Seals Factory Applied Side Lap Tape All side laps have a factory applied anti condensation tape. * Please note we do not recommend a PVDF or Celestia coating on roof applications. Therefore we only stock a limited range of colours in these two coating ranges. Please contact Quotations to discuss once colour reference is known. 12

13 Performance Thermal Insulation Panel Thickness (mm) U value W/m 2 K * * U - Thermal transmittance W/m 2 K * U Value calculated in accordance with the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Part J (Scotland) Biological Kingspan panels are normally immune to attack from mould, fungi, mildew and vermin. No urea formaldehyde is used in the construction, and the panels are not considered deleterious. Fire Steel and aluminium outer and inner facings have Class 1 surface spread of flame to BS 476: Part 7: 1987, and are Class 0, as defined by Building Regulations. The panel surfaces are rated FAA/SAA to BS 476: Part 3: KS1000 LP/CR insurer approved panels are available with FM and LPCB certification, with steel facings. For KS1000 CR/FM contact Kingspan Technical Design Bureau. Acoustics KS1000 LP/CR panels comply with Building Regulations Part E for non-domestic buildings. For residential, domestic, education and healthcare building applications, BB93 and HTM 2045 solutions, consult Kingspan Technical Design Bureau. All KS1000 LP/CR panels have a single figure weighted sound reduction Rw = 25dB. Sound Reduction Index (SRI) Tested Frequency Hz k 2k 4k SRI db Quality & Durability Kingspan Insulated Panels are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, complying with ISO 9001: 2000 standard, ensuring long term reliability and service life. Guarantees & Warranties Kingspan will provide external coating and product warranties and guarantees on an individual project basis. Packing Standard Packing KS1000 LP/CR panels are stacked weather sheet to weather sheet (to minimise pack height). The top, bottom, sides and ends are protected with foam and timber packing and the entire pack is wrapped in plastic. The number of panels in each pack depends on panel thickness and length. The table below is shown as a guide. Typical pack height is 1100mm. Maximum pack weight is 1500kg. Panel Core Thickness No. panel/pack (max.) Sea Freight Fully timber crated packs are available on projects requiring delivery by sea freight shipping, at additional cost. Alternatively, steel containers can be used. Special loading charges apply. Delivery All deliveries (unless indicated otherwise) are by road transport to project site. Off loading is the responsibility of the client. Site Installation Procedure Site assembly instructions are available from the Kingspan Technical Design Bureau. Building Regulations & Standards Kingspan insulated roof and wall systems conform to the following Building Regulations and Standards (Non-domestic buildings): i) Approved Document A: Structure (England & Wales) ii) Approved Document B: Fire (England & Wales) iii) Approved Document E: Resistance to the Passage of Sound (England & Wales) iv) Approved Document Part L2: Conservation of Fuel & Power (England & Wales) v) Building Standard Part D: Structural Fire Precautions (Scotland) vi Building Standard Part H: Resistance to the Transmission of Sound (Scotland) vii) Building Standard Part J: Conservation of Fuel & Power (Scotland) viii) Building Standard Part L: Conservation of Fuel & Energy (Ireland) 13

14 Product Data Structural Unfactored Load/Span Table (use calculated design windload values unfactored) SPAN Core Load Uniformly Distributed Loads (kn/m 2 ) CONDITION Thickness Type Span L in Metres (mm ) SINGLE SPAN 45 Downwards Suction Outer Sheet 60 Downwards mm steel Suction Inner Sheet 80 Downwards mm steel Suction L 100 Downwards Suction DOUBLE SPAN 45 Downwards Suction Outer Sheet 60 Downwards mm steel Suction Inner Sheet 80 Downwards mm steel Suction L L 100 Downwards Suction Notes: 1. Values have been calculated using the limit state method described in the European Recommendations for the Design of Sandwich Panels (ECCS document No ), taking imposed loads, temperature and creep into account. 2. For each value individual and combined load cases with appropriate load factors and temperatures have been considered. These are detailed under Structural Performance in the Building Design Section. 3. The Table is for medium and light coloured panels, as recommended by Kingspan for roofs. 4. The following deflection limits have been used: Downward loading L /200 Suction loading L / For intermediate values linear interpolation may be used. 6. The actual wind suction load resisted by the panel is dependant on the number of fasteners used and the material of the purlin. The fasteners calculation should be carried out in accordance with the appropriate standard. For further advise please contact Kingspan Technical Design Bureau. 7. The allowable steelwork tolerance between bearing planes of adjacent purlins is +/- 5mm. 8. Load span tables for panel specifications not shown are available from the Kingspan Technical Design Bureau. 9. FM approved panels spans must be limited to a maximum of 1.8 metres in single or double span conditions. 14

15 15

16 Model Specifications KS1000 LP/Zero ODP/LPCB Lo-Pitch Roof System Lo-Pitch of 4 or above Roof LPS 1181 Grade EXT-B Ref No: 1/5.74A/LPS-B Application The following specification is for the KS1000 LP/Zero ODP/LPCB Lo-Pitch Insulated Roof Panel used for buildings with roof slopes of 4 and above with internal humidity class environments 1-4 inclusive as defined in BS EN ISO 13788:2002. For internal humidity class environment 5 i.e. swimming pools contact Kingspan Technical Design Bureau. KS1000 LP is Loss Prevention Certification Board LPCB certified to LPS 1181 Grade EXT-B. Materials & Coatings External Weather Sheet Substrate to be 0.5mm thick steel S220GD+ZA eutectic Galvalloy hot-dip zinc coated steel to BS EN10214: External coating to be Plastisol, nominal 200 micron thick. Colour Standard SC. Reverse to have a light grey polyester coating. Insulation Core To consist of 80mm thick, closed cell, with zero ozone depletion (Zero ODP) and LPCB certified polyisocyanurate (PIR) insulation. The auto-adhesive properties of the core bond the external and internal sheets together, and control the panel thickness achieved during manufacture. Internal Liner Sheet Substrate to be 0.4mm thick hot-dip zinc coated Steel to BS EN10147: Internal coating to be Lining Enamel, nominal 15 micron thick. Colour - White. Reverse to have a light grey polyester coating. Cover Caps To be made from 0.5mm thick steel coated to the same specification as the external weather sheet of the panels and used in typical lengths up to 12000mm. Performance Thermal Insulation The panel must have a thermal transmittance (U value) of 0.25 W/m 2 K calculated using the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Part J (Scotland). Fire The external and internal faces of the panel to be Class 0 in accordance with the Building Regulations when tested to BS 476: Parts 6: 1989 and Part 7: The panel must be rated SAA when tested to BS 476: Part 3: The system has passed all the requirements of LPS 1181: 2003: Part 1: Issue 1 ceiling lining test. Airtightness Overall airtightness for complete envelope less than 10m 3 /hr/m 2 at 50Pa. 16

17 Seals & Fillers Side Joint All side joints have a factory applied anti-condensation tape. End Lap All external end laps to be 75mm long, and weather sealed along the full width using a single unbroken run of 18mm wide x 4mm thick U section butyl rubber sealant tape, Class A, Ref NFRC TB93. In addition a single unbroken run of non-curing mastic applied across the complete width of the panel. End laps to be tail stitched with carbon steel stitching screws, complete with 14mm diameter bonded stainless steel washers. Tail stitching to be positioned 25mm upslope from end lap and five number per panel. Fasteners to penetrate the factory applied end lap stitching plate positioned in the downslope panel at the flush end. An additional 150mm length of gun applied non-curing mastic to be applied over 4 way laps. Profiled Fillers Where flashings are fixed across the profile of the insulated panel, EPDM closed cell foam fillers should be used to seal and close the profile. Seal the top, bottom and sides of each profiled filler with non-setting gun-grade sealant, Scapa Tapes Ref: 0100 or similar. The flashing and filler to be supported using an apex dam Ref: LP1. Junctions Junctions between the roof panel system and walls / penetrations insulated with PIR board insulation any gaps filled with Alfasbond FR or similar fire rated gun applied canister urethane insulation. Internal face of panel to be air sealed along the full length by an unbroken 6mm diameter butyl rubber sealant tape, Class A, Ref NFRC TB93. Fasteners Primary All primary fasteners must be the high threaded type, manufactured from carbon steel and fitted with a 16mm diameter bonded stainless steel washer. All fasteners to be located at the side profile of the panel. To comply with the requirements of BS 6399: Part 2: 1997, it may be necessary to provide additional fixings in areas of high local suction. Secondary Flashings to be stitched at 450mm centres (maximum) with carbon steel, stitching screws, complete with 14mm diameter bonded stainless steel washers with integral colour matched heads. Fasteners General Note Recommended fasteners are available. For a full list contact Technical Design Bureau. 17

18 Model Specifications KS1000 LP/Zero ODP/LPCB Lo-Pitch Roof System Lo-Pitch of 4 or above Roof LPS 1181 Grade EXT-B Ref No: 1/5.74A/LPS-B Construction Details Flashings All external flashings to be made from 0.63mm thick steel to the same specification as the outer sheet of the panel. Colour Standard. All flashings to be weather sealed at laps and along the full length by an unbroken bead of 20mm wide x 3mm thick butyl rubber sealant tape, Class A, Ref NFRC TB93. All internal flashings to be made from 0.4mm thick steel substrate, to the same specification as the inner sheet. Colour white. All internal flashings to be air sealed at laps and along the full length by an unbroken bead of 6mm diameter butyl rubber sealant tape, Class A, Ref NFRC TB93. End laps to be air sealed with Scapa Tape Vapourflex or similar, or gun-grade sealant. Panel Lengths Exact lengths to be determined by the cladding contractor from the steelwork drawing, but typically using minimum number of panels from ridge to eaves up to a maximum panel length of 28.5 metres. Construction Requirements Steelwork Tolerance The steel frame must be made and assembled to an accuracy of L/600 between fixing planes of adjacent purlins, +/- 5mm. Installation All fasteners, seals and fillers to be of correct specification and installed as indicated on the project construction drawings. Site cut panels must provide accurate, true lines with no distortion. Panels to be cut with powered reciprocating type saw and all exposed site cut panels to be treated with a suitable edge protection lacquer. Cut openings for outlets, vents, flues etc. to be the minimum size necessary. Remove all swarf and any foreign matter immediately from the external surface of panels. Fasteners to be checked and adjusted if necessary to ensure they are weather tight and external panel facing is not distorted. Safety The contractor is to determine and use a safe method of working throughout the installation and construction period, which complies with HSE & CDM requirements. NBS Format Specification H43 - Metal Composite Panel Cladding/Covering To be read with Preliminaries/General conditions. 122A - Metal Composite Roof Cladding Drawing reference(s): Supports: Cold rolled purlins Bearing width: 50mm Pitch: Min 4 or above (Finished roof slope after deflections). Manufacturer and reference: Kingspan roof cladding system for standard internal and external environments and Loss Prevention Certification Board certified to LPS 1181 Grade EXT-B. Test results: LPS 1181: 2003: Part 1: Issue 1, ceiling lining tests: Passed all requirements. Panels: Profile reference: KS1000 LP/Zero ODP/LPCB - Lo-Pitch Insulated Roof Panel. External facings: Material: Galvalloy hot-dip ZA255 coated steel to BS EN 1021, Grade S220GD+ZA. Thickness: 0.5mm Finish/Colour: Nominal 200micron Plastisol, Standard colour. Internal facings: Material: Hot-dip zinc coated steel to BS EN Thickness: 0.4mm Finish/Colour: Lining Enamel, colour White. Core insulation: Zero ODP and LPCB certified. Panel thickness: 115mm overall (80mm core) End laps: 75mm. End lap sealant: Single line of 18mm x 4mm U shaped butyl rubber sealant, Class A, Ref NFRC TB93, site applied at lap in external facings. Single line of non-setting gun-grade, Scapa Tapes, Ref: 0100 or similar, site applied at lap in external facings. Non-setting gun-grade, Scapa Tapes, Ref: 0100 or similar, site applied to corners of profile at end lap. Side lap sealant: Two anti-condensation tapes, factory applied at butt joint between panels. Fasteners: As determined by Clause 220C. Number and location: Primary fasteners: As determined by Clause 197A, but with each panel fixed to each support using not less than two fastenings, located through the side panels as recommended by cladding manufacturer. Secondary fasteners: Stitch external end laps using five fastenings per panel, located 25mm upslope from end lap, penetrating factory applied stitching plate on underside of down slope panel. S U L P 18

19 KS1000 LP/Zero ODP/LPCB Lo-Pitch Roof System Lo-Pitch of 4 or above Roof LPS 1181 Grade EXT-B Ref No: 1/5.74A/LPS-B Cover Caps: Material: As per external facings. Thickness: 0.5mm Finish/Colour: Colorcoat as per external facings, colour standard. Sealant: Single line of non-setting gun-grade, Scapa Tapes, Ref: 0100 or similar, site applied at 4 way laps. Factory applied sealant tape at junction with panels. Accessories: Profiled fillers as Clause 300A. Apex dams and profiled fillers as per manufacturers recommendations, where flashing cross the profile of the panel. Apex dams as determined by Clause 310A. Thermal Transmittance (U Value) calculated using the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Part J (Scotland): 0.25 W/m 2 K Air leakage rate of 10m 3 /hr/m 2 at 50 Pa. Other requirements: Internal face of panel to be air sealed along the full length by an unbroken run of 6mm diameter butyl rubber sealant Class A, Ref NFRC TB A - Attachment Determine the number and location of cladding fasteners recommended by the cladding manufacturer to resist wind loads calculated in accordance with BS 6399:Part 2 Standard Method and BS 5427: Part 1. Calculate wind loads on roof and wall cladding appropriate to location, exposure, roof height, building shape and size in accordance with BS 6399: Part 2 Standard Method and BS 5427: Part 1. Basic wind speed (Vb): m/s Altitude factor (Sa): Direction factor (Sd): Seasonal factor (Ss): 1 Probability factor (Sp): 1 Terrain and building factor (Sb): External and internal size effect factors (Ca): 1 External pressure coefficients (Cpe): As determined from BS 6399: Part 2, Clauses 2.4 and 2.5. Internal pressure coefficients (Cpi): As determined from BS 6399: Part 2, Clause 2.6. Dominant opening: 220C - Fasteners Recommended Manufacturer: One of the following: SFS Intec Limited, tel Ejot UK Limited, tel Mage Fasteners Limited, tel Ash and Lacy Building Systems Limited, tel Primary fasteners: High threaded screws with bonded washers. Type(s), size(s) and drilling capacity: As recommended by fastener manufacturer to suit type and thickness of supports, and thickness of cladding panels. Screw material: Anti-corrosion coated carbon steel. Washer material: Grade 304 austenitic stainless steel. Washer size: 16mm diameter. Heads: Not coloured Secondary fasteners: Stitching screws with bonded washers. Screw/washer material: As primary fasteners. Washer size: 14mm diameter. Heads: Integral colour matched heads. 275A - Continuity Thermal Insulation Junctions between the roof panel system and walls/ penetrations insulated with PIR board insulation any gaps filled with Alfasbond FR or similar fire rated gun applied canister urethane insulation. Placement: Secure and continuous with cladding/covering insulation. 300A - Profiled Fillers Drawing reference(s): Manufacturer and reference: Premier Sealant Systems Limited Ref: E25 or similar, type to suit cladding profile. Material: EPDM foam. Colour: Black. Fixing: Seal the top, bottom and sides of each profiled filler with a non-setting gun-grade, Scapa Tapes, Ref: 0100 or similar. Locate where shown on drawings and wherever necessary to close off corrugation cavities from the inside and outside of the building. Ensure a tight fit and leave no gaps. 310A - Purpose Made Cold Formed Metal Accessories External Drawing reference(s): Material/finish: As external face of cladding. Thickness: 0.63mm Colour: To match external face of cladding. Workmanship as section Z11. Fixing: Stitch to external face of panels at 400mm centres using secondary fasteners as specified for the cladding system. Sealing: Single line of 20mm x 3mm butyl rubber sealant Class A, Ref NFRC TB93, site applied between flashing and panel. 311A - Purpose Made Cold Formed Metal Accessories - Internal Drawing reference(s): Material/finish: As internal face of cladding. Thickness: 0.4mm Colour: White. Workmanship as section Z11. Fixing: Stitch to internal face of panels at 450mm centres using stainless steel secondary fasteners as specified for the cladding system. Sealing: Single line of 6mm diameter butyl rubber sealant Class A, Ref NFRC TB93, site applied between flashing and panel. End laps to be air sealed with Scapa Tapes Vapourflex or similar, or gun-grade sealant. 19

20 Model Specifications KS1000 LP/Zero ODP/LPCB Lo-Pitch Roof System Lo-Pitch of 4 or above Roof LPS 1181 Grade EXT-B Ref No: 1/5.74A/LPS-B Detail 1 - Side Lap Detail 2 - End Lap Snap-on matching/ contrasting cover cap Factory applied anti-condensation tape Panel fastener 25mm 75mm Position of tail stitching screws 18mm x 4mm U section butyl rubber end lap sealant Continuous bead of gun-grade sealant Concealed through fastener Factory applied end lap stitching plate Detail 3 - Fastener Locations Note: For curved end lap detail please see page 35. End lap tail stitching screws Panel fastener Detail 4 - Ridge Detail Ridge flashing with 150mm sealed butt straps Cover cap Profiled filler set back 80 to 100mm to prevent bird attack Site applied Alfasbond fire rated (FR) canister insulation Apex dam (Ref: LP1) Bead of non-curing gun-grade sealant Profiled filler sealed top and bottom with gun-grade sealant KS1000 LP/LPCB insulated roof panel Internal ridge flashing with 150mm overlap sealed with Vapourflex or gun-grade sealant 2 No. runs of non-curing gun-grade sealant Air seal - 8mm Ø butyl rubber sealant Purlin Note: For KS1000 CR (Curved) Model Specification construction details contact Kingspan Technical Design Bureau. 20

21 KS1000 LP/Zero ODP/LPCB Lo-Pitch Roof System Lo-Pitch of 4 or below Roof LPS 1181 Grade EXT-B Ref No: 1/5.74B/LPS-B Application The following specification is for the KS1000 LP/Zero ODP/LPCB Lo-Pitch Insulated Roof Panel used for buildings with roof slopes of 1.5 or curved roofs of 150m radius and above with internal humidity class environments 1-4 inclusive as defined in BS EN ISO 13788:2002. For internal humidity class environment 5 i.e. swimming pools contact Kingspan Technical Design Bureau. KS1000 LP is Loss Prevention Certification Board (LPCB) certified to LPS 1181 Grade EXT-B. Materials & Coatings External Weather Sheet Substrate to be 0.5mm thick steel S220GD+ZA eutectic Galvalloy hot-dip zinc coated steel to BS EN10214: External coating to be Plastisol, nominal 200 micron thick. Colour Standard. Reverse to have a light grey polyester coating. Insulation Core To consist of 80mm thick, closed cell, with zero ozone depletion (Zero ODP) and LPCB certified polyisocyanurate (PIR) insulation. The auto-adhesive properties of the core bond the external and internal sheets together, and control the panel thickness achieved during manufacture. Internal Liner Sheet Substrate to be 0.4mm thick hot-dip zinc coated Steel to BS EN10147: Internal coating to be Lining Enamel, nominal 15 micron thick. Colour - White. Reverse to have a light grey polyester coating. Cover Caps To be made from 0.5mm thick steel coated to the same specification as the external weather sheet of the panels and used in typical lengths up to 12000mm. Performance Thermal Insulation The panel must have a thermal transmittance (U value) of 0.25 W/m 2 K calculated using the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Part J (Scotland). Fire The external and internal faces of the panel to be Class 0 in accordance with the Building Regulations when tested to BS 476: Parts 6: 1989 and Part 7: The panel must be rated SAA when tested to BS 476: Part 3: The system has passed all the requirements of LPS 1181: 2003: Part 1: Issue 1 ceiling lining test. Airtightness Overall airtightness for complete envelope less than 10m 3 /hr/m 2 at 50Pa. Seals & Fillers Side Joint All side joints have a factory applied anti-condensation tape. End Lap All external end laps to be 75mm long, and weather sealed along the full width using a single unbroken run of 18mm wide x 4mm thick U section butyl rubber sealant tape, Class A, Ref NFRC TB93. In addition a single unbroken run of non-curing mastic applied across the complete with of the panel. End laps to be tail stitched with carbon steel stitching screws, complete with 14mm diameter bonded stainless steel washers. Tail stitching to be positioned 25mm upslope from end lap and five number per panel. Fasteners to penetrate the factory applied end lap stitching plate positioned in the downslope panel at the flush end. An additional 150mm length of gun applied non-curing mastic to be applied over 4 way laps. Profiled Fillers Where flashings are fixed across the profile of the insulated panel, EPDM closed cell foam fillers should be used to seal and close the profile. Seal the top, bottom and sides of each profiled filler with non-setting gun-grade sealant, Scapa Tapes Ref: 0100 or similar. The flashing and filler to be supported using an apex dam, Ref: LP1. Junctions Junctions between the roof panel system and walls / penetrations insulated with PIR board insulation any gaps filled with Alfasbond FR or similar fire rated gun applied canister urethane insulation. Internal face of panel to be air sealed along the full length by an unbroken 6mm diameter butyl rubber sealant tape, Class A, Ref NFRC TB93. Fasteners Primary All primary fasteners must be the high threaded type, manufactured from carbon steel and fitted with a 16mm diameter bonded stainless steel washer. All fasteners to be located at the side profile of the panel. To comply with the requirements of BS 6399: Part 2: 1997, it may be necessary to provide additional fixings in areas of high local suction. Secondary Flashings to be stitched at 450mm centres (maximum) with carbon steel, stitching screws, complete with 14mm diameter bonded stainless steel washers with integral colour matched heads. Fasteners General Note Recommended fasteners are available from SFS Intec Ltd, Ejot UK Ltd, Mage Fasteners Ltd, or Ash and Lacy Building Systems Ltd. 21

22 Model Specifications KS1000 LP/Zero ODP/LPCB Lo-Pitch Roof System Lo-Pitch of 4 or below Roof LPS 1181 Grade EXT-B Ref No: 1/5.74B/LPS-B Construction Details Flashings All external flashings to be made from 0.63mm thick steel to the same specification as the outer sheet of the panel. Colour Standard. All flashings to be weather sealed at laps and along the full length by an unbroken bead of 20mm wide x 3mm thick butyl rubber sealant tape, Class A, Ref NFRC TB93. All internal flashings to be made from 0.4mm thick steel substrate, to the same specification as the inner sheet. Colour - white. All internal flashings to be air sealed at laps and along the full length by an unbroken bead of 6mm diameter butyl rubber sealant tape, Class A, Ref NFRC TB93. End laps to be air sealed with Scapa Tapes Vapourflex or similar, or gun-grade sealant. Ridge and Eaves The outer sheet of the panel must be turned up and turned down using cladding manufacturers supplied tool at ridge and eaves respectively. Panel Lengths Exact lengths to be determined by the cladding contractor from the steelwork drawing, but typically using minimum number of panels from ridge to eaves up to a maximum panel length of 28.5 metres. Construction Requirements Steelwork Tolerance The steel frame must be made and assembled to an accuracy of L/600 between fixing planes of adjacent purlins, +/- 5mm. Installation All fasteners, seals and fillers to be of correct specification and installed as indicated on the project construction drawings. Site cut panels must provide accurate, true lines with no distortion. Panels to be cut with powered reciprocating type saw and all exposed site cut panels to be treated with a suitable edge protection lacquer. Cut openings for outlets, vents, flues etc. to be the minimum size necessary. Remove all swarf and any foreign matter immediately from the external surface of panels. Fasteners to be checked and adjusted if necessary to ensure they are weather tight and external panel facing is not distorted. Safety The contractor is to determine and use a safe method of working throughout the installation and construction period, which complies with HSE & CDM requirements. NBS Format Specification H43 - Metal Composite Panel Cladding/Covering To be read with Preliminaries/General conditions. 122A - Metal Composite Panel Drawing reference(s): Supports: Cold rolled purlins Bearing width: 50mm Pitch: Min 1.5 or above (Finished roof slope after deflections). Manufacturer and reference: Kingspan roof cladding system for standard internal and external environments and Loss Prevention Certification Board certified to LPS 1181 Grade B. Test results: LPS 1181, Issue 3, ceiling lining tests: Passed all requirements. Panels: Profile reference: KS1000 LP/Zero ODP/LPCB - Lo-Pitch Insulated Roof Panel. External facings: Material: Galvalloy hot-dip ZA255 coated steel to BS EN 10212, Grade S220GD+ZA. Thickness: 0.5mm Finish/Colour: Nominal 200 micron Plastisol, standard colour. Internal facings: Material: Hot-dip zinc coated steel to BS EN Thickness: 0.4mm Finish/Colour: Lining Enamel, colour White. Core insulation: Zero ODP and LPCB certified. Panel thickness: 115mm overall (80mm core) End laps: 75mm. End lap sealant: Single line of 18mm x 4mm U shaped butyl rubber sealant, Class A, Ref NFRC TB93, site applied at lap in external facings. Single line of non-setting gun-grade, Scapa Tapes, Ref: 0100 or similar, site applied at lap in external facings. Non-setting gun-grade, Scapa Tapes, Ref: 0100 or similar, site applied to corners of profile at end lap. Side lap sealant: Two anti-condensation tapes, factory applied at butt joint between panels. Fasteners: As determined by Clause 220C. Number and location: Primary fasteners: As determined by Clause 197A, but with each panel fixed to each support using not less than two fastenings, located through the side panels as recommended by cladding manufacturer. Secondary fasteners: Stitch external end laps using five fastenings per panel, located 25mm upslope from end lap, penetrating factory applied stitching plate on underside of down slope panel. 22

23 KS1000 LP/Zero ODP/LPCB Lo-Pitch or Curved Roof System Lo-Pitch of 4 or below Roof LPS 1181 Grade EXT-B Ref No: 1/5.74B/LPS-B Cover Caps: Material: As per external facings. Thickness: 0.5mm Finish/Colour: Colorcoat as per external facings, colour standard. Sealant: Single line of non-setting gun-grade, Scapa Tapes, Ref: 0100 or similar, site applied at 4 way laps. Accessories: Profiled fillers as Clause 300A. Apex dams and profiled fillers as per manufacturers recommendations, where flashing cross the profile of the panel. Apex dams as determined by Clause 310A. Thermal Transmittance (U Value) calculated using the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Part J (Scotland): 0.25 W/m 2 K Air leakage rate of 10m 3 /hr/m 2 at 50 Pa. Other requirements: Internal face of panel to be air sealed along the full length by an unbroken run of 6mm diameter butyl rubber sealant, Class A, Ref NFRC TB93. Turn up and turn down using cladding manufacturers supplied tool at ridge and eaves respectively. 197A - Attachment Determine the number and location of cladding fasteners recommended by the cladding manufacturer to resist wind loads calculated in accordance with BS 6399: Part 2 Standard Method and BS 5427: Part 1. Calculate wind loads on roof and wall cladding appropriate to location, exposure, roof height, building shape and size in accordance with BS 6399: Part 2 Standard Method and BS 5427: Part 1. Basic wind speed (Vb): m/s Altitude factor (Sa): Direction factor (Sd): Seasonal factor (Ss): 1 Probability factor (Sp): 1 Terrain and building factor (Sb): External and internal size effect factors (Ca): 1 External pressure coefficients (Cpe): As determined from BS 6399: Part 2, Clauses 2.4 and 2.5. Internal pressure coefficients (Cpi): As determined from BS 6399: Part 2, Clause 2.6. Dominant opening: 220C Fasteners Recommended Manufacturer: One of the following: SFS Intec Limited, tel Ejot UK Limited, tel Mage Fasteners Limited, tel Ash and Lacy Building Systems Limited, tel Primary fasteners: High threaded screws with bonded washers. Type(s), size(s) and drilling capacity: As re-commended by fastener manufacturer to suit type and thickness of supports, and thickness of cladding panels. Screw material: Anti-corrosion coated carbon steel. Washer material: Grade 304 austenitic stainless steel. 23 Washer size: 16mm diameter. Heads: Not coloured Secondary fasteners: Stitching screws with bonded washers. Screw/washer material: As primary fasteners. Washer size: 14mm diameter. Heads: Coloured plastic heads. 275A - Continuity Thermal Insulation Junctions between the roof panel system and walls/penetrations insulated with PIR board insulation any gaps filled with Alfasbond FR or similar fire rated gun applied canister urethane insulation. Placement: Secure and continuous with cladding/covering insulation. 300A - Profiled Fillers Drawing reference(s): Manufacturer and reference: Premier Sealant Systems Limited Ref: E25 or similar, type to suit cladding profile. Material: EPDM foam. Colour: Black. Fixing: Seal the top, bottom and sides of each profiled filler with a non-setting gun-grade, Scapa Tapes, Ref: 0100 or similar. Locate where shown on drawings and wherever necessary to close off corrugation cavities from the inside and outside of the building. Ensure a tight fit and leave no gaps. 310A - Purpose Made Cold Formed Metal Accessories External Drawing reference(s): Material/finish: As external face of cladding. Thickness: 0.63mm Colour: To match external face of cladding. Workmanship as section Z11. Fixing: Stitch to external face of panels at 400mm centres using secondary fasteners as specified for the cladding system. Sealing: Single line of 20mm x 3mm butyl rubber sealant, Class A, Ref NFRC TB93, site applied between flashing and panel. 311A - Purpose Made Cold Formed Metal Accessories - Internal Drawing reference(s): Material/finish: As internal face of cladding. Thickness: 0.4mm Colour: White. Workmanship as section Z11. Fixing: Stitch to internal face of panels at 450mm centres using stainless steel secondary fasteners as specified for the cladding system. Sealing: Single line of 6mm diameter butyl rubber sealant, Class A, Ref NFRC TB93, site applied between flashing and panel. End laps to be air sealed with Scapa Tapes Vapourflex or similar, or gun-grade sealant.

24 Model Specifications KS1000 LP/Zero ODP/LPCB Lo-Pitch Roof System Lo-Pitch of 4 or below Roof LPS 1181 Grade EXT-B Ref No: 1/5.74B/LPS-B Detail 1 - Side Lap Detail 2 - End Lap Snap-on matching/ contrasting cover cap Factory applied anti-condensation tape Panel fastener Position of tail stitching screws 25mm 75mm 18mm x 4mm U section butyl rubber end lap sealant Continuous bead of gun-grade sealant Concealed through fastener Factory applied end lap stitching plate Detail 3 - Fastener Locations Note: For curved end lap details please see page 35 End lap tail stitching screws Panel fastener Detail 4 - Ridge Detail Ridge flashing with 150mm sealed butt straps Cover cap Profiled filler set back 80 to 100mm to prevent bird attack Outer sheet turned up Site applied Alfasbond fire rated (FR) canister insulation Apex dam (Ref: LP1) Bead of non-curing gun-grade sealant Profiled filler sealed top and bottom with gun-grade sealant KS1000 LP/LPCB insulated roof panel 2 No. runs of noncuring gungrade sealant Air seal - 8mm Ø butyl rubber sealant Internal ridge flashing with 150mm overlap sealed with Vapourflex or gun-grade sealant Purlin Note: For KS1000 CR (Curved) Model Specification construction details contact Kingspan Technical Design Bureau. 24

25 25

26 Construction Details 26

27 Panel Dimensions 1000 cover width A B Fastener location Anti condensation tape (Factory applied) 3mm Radius External weather sheet Fastener location 53 3 Anti condensation tape (Factory applied) Insulation core Internal liner sheet Note: Two sets of construction details have been produced to give the building designer flexibility within the Part L2 calculation for the total building heat loss Alpha (α). The decision on the choice of STANDARD or ENHANCED details is taken by the building designer and is determined from the Part L2 total heat loss methodology. A mixture of both standard and enhanced details may be required for some projects. Available Panel Thicknesses Insulation Overall Panel Core (A) Thickness (B) Note: Above dimensions are theoretical, actual dimensions will vary due to manufacturing tolerances. Exactly precise dimensions must always be measured from actual samples All dimensions in millimetres. 27

28 Construction Details End Lap Detail Snap-on cover cap over lower cover cap End of cover cap pointed with mastic Cover cap 18mm x 4mm U section butyl rubber sealant End lap fixing/ stitching screw 10mm Max 75mm End lap 25mm 15mm 75mm factory formed joint Continuous bead of gun-grade sealant 2 runs of noncuring gungrade mastic to side joint Factory fitted end lap stitching plate 30mm Min 10mm Min Minimum of 300mm between panel end lap and cover cap end lap Continuous bead of non-curing gun-grade sealant End Lap Stitching Screw Locations 28

29 Ridge Detail STANDARD Mineral fibre insulation ENHANCED Ridge flashing with 150mm sealed butt straps Cover cap Profiled filler set back 80 to 100mm to prevent bird attack Site applied Alfasbond or similar fire rated (FR) canister insulation Outer sheet turned up with roof slopes below 4 Apex dam (Ref: LP1) Bead of non-curing gun-grade sealant Profiled filler sealed top and bottom with gun-grade sealant Air seal - 8mm Ø butyl rubber sealant KS1000 LP/LPCB insulated roof panel Internal ridge flashing with 150mm overlap sealed with Vapourflex or gungrade sealant or similar STANDARD Building Regulations Part L2 Thermal Data fmin = 0.97 Ψ = 0.01 W/mK The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values. 2 No. runs of non curing gungrade sealant Air seal - 8mm Ø butyl rubber sealant ENHANCED Purlin Building Regulations Part L2 Thermal Data fmin = 0.97 Ψ = W/mK The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values. 29

30 Construction Details Eaves Detail Parapet Detail -Boundary Wall Gutter Parapet flashing with 150mm sealed butt straps Mineral fibre insulation site applied Butyl rubber sealant Parapet rail with air seal - Vapourflex or similar to rail joints Air seal - 6mm Ø butyl rubber sealant Profiled filler sealed top and bottom with gun-grade sealant Air seal - 6mm Ø bead of gun-grade sealant 4mm Ø butyl rubber sealant Air seal - 6mm Ø butyl rubber sealant KS1000 MR/ LPCB wall panel horizontally laid KS1000 RW/ LPCB wall panel vertically laid Sheeting rail Mineral fibre insulation site applied 60mm 35mm min Top sheet turned down on site with roof pitches below 4 Gun-grade seal at panel joints inline with 8mm butyl Air seal - 8mm Ø butyl rubber sealant 2mm external non-thermally broken factory made gutter with PIR insulation to 0.25 or 0.35 W/m 2 K U-value 75mm KS1000 LP/LPCB insulated roof panel Purlin Direction of lay STANDARD Building Regulations Part L2 Thermal Data 0.25 W/m 2 K gutter fmin = 0.48 Ψ = 1.63 W/mK 0.35 W/m 2 K gutter fmin = 0.48 Ψ = 1.72 W/mK 0.35 sole width 300mm and depth 150mm, values for other widths available on request. The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values. Gutter outlet Eaves beam gutter support ENHANCED ENHANCED Site applied Alfasbond or similar fire rated (FR) canister insulation Site applied PIR board insulation ENHANCED Site applied Alfasbond or similar fire rated (FR) canister insulation Factory made thermally broken membrane lined gutter with PIR board insulation to 0.25 or 0.35 W/m 2 K U-value Building Regulations Part L2 Thermal Data 0.25 W/m 2 K gutter fmin = 0.90 Ψ = 0.13 W/mK 0.35 W/m 2 K gutter fmin = 0.90 Ψ = 0.21 W/mK 0.35 sole width 300mm and depth 150mm, values for other widths available on request. The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values. 30

31 Eaves Detail Eaves Detail - External Gutter Gutter support 0.63mm thick doubled sided plastisol coated 75mm Approx 200mm fixing centres 200mm fixing centres Top sheet turned down on site with roof pitches below 4 0 Gun -grade sealant at panel joints inline with 8mm butyl 20mm x 3mm butyl rubber sealant Stitching screw fixings for gutter brackets KS1000 LP/LPCB insulated roof panel Double sided Plastisol Highline type gutter Eaves beam 20 mm mm 35 mm 20 KS1000 MR/ LPCB wall panel horizontally laid Air seal - Vapourflex or similar sealant * is to be applied over any breaks in supporting secondary steelwork to give a continuous bearing face. STANDARD Building Regulations Part L2 Thermal Data fmin = 0.95 Ψ = 0.31 W/mK The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values. * Air seal - 8mm Ø butyl rubber sealant STANDARD Mineral fibre insulation site applied ENHANCED Site applied Alfasbond or similar fire rated (FR) canister insulation Air seal - 6mm Ø butyl rubber sealant ENHANCED Building Regulations Part L2 Thermal Data fmin = 0.95 Ψ = 0.13 W/mK The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values. 50mm Gutter support 0.63mm thick HPS200 coating both sides Cover cap 40mm 30mm Stitching screw fixings for gutter brackets Internal liner sheet Concealed through fastener 31

32 Construction Details Valley Gutter Detail Valley Gutter Detail Cover cap Top sheet turned down on site with roof pitches below 4 75mm Gun-grade seal at panel joints inline with 8mm butyl Air seal - 8mm Ø butyl rubber sealant 2mm external non-thermally broken factory made gutter with PIR insulation to 0.25 or 0.35 W/m 2 K U-value Stanchion head tie if necessary as steelwork design Gutter outlet offset to miss stanchion head tie Air seal - 8mm Ø butyl rubber sealant Purlin STANDARD Building Regulations Part L2 Thermal Data 0.25 W/m 2 K gutter fmin = 0.74 Ψ = 1.07 W/mK 0.35 W/m 2 K gutter fmin = 0.71 Ψ = 1.38 W/mK 0.35 sole width 600mm and depth 150mm, values for other widths available on request. The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values. Valley Gutter Detail Cover cap ENHANCED 75mm Gun-grade seal at panel joints inline with 8mm butyl Top sheet turned down on site with roof pitches below 4 Air seal - 8mm Ø butyl rubber sealant Factory made thermally broken membrane lined gutter with PIR board insulation to 0.25 or 0.35 W/m 2 K U-value Stanchion head tie if necessary as steelwork design Gutter outlet offset to miss stanchion head tie Air seal - 8mm Ø butyl rubber sealant Purlin ENHANCED Building Regulations Part L2 Thermal Data 0.25 W/m 2 K gutter fmin = 0.96 Ψ = 0.13 W/mK 0.35 W/m 2 K gutter fmin = 0.96 Ψ = 0.25 W/mK 0.35 sole width 600mm and depth 150mm, values for other widths available on request. The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values. 32

Lo-Pitch & Curved. Insulated Roof System. Product Data 257. Model Specifications 261. Fastener Selection 271. Construction Details 273

Lo-Pitch & Curved. Insulated Roof System. Product Data 257. Model Specifications 261. Fastener Selection 271. Construction Details 273 Product Data 257 Model Specifications 261 Fastener Selection 271 Construction Details 273 Panel Dimensions 273 Side Joint & Panel/ Cover Cap Lap 274 End Lap 275 Ridge 276 Eaves 278 Valley Gutter 281 Verge

More information

Insulated Roof & Wall Panels. Product Data Sheet. Lo-Pitch Insulated Roof Panel KS1000 LP

Insulated Roof & Wall Panels. Product Data Sheet. Lo-Pitch Insulated Roof Panel KS1000 LP Insulated Roof & Wall Panels Insulated Roof Panel KS1000 LP Applications The KS1000 LP is a secret-fix shallow profiled insulated roof panel with raised side joints. This panel is ideal for all applications

More information

Insulated Roof & Wall Panels. Product Data Sheet. Curved Roof Insulated Panel KS1000 CR

Insulated Roof & Wall Panels. Product Data Sheet. Curved Roof Insulated Panel KS1000 CR Insulated Roof & Wall Panels Insulated Panel KS1000 CR Applications The KS1000 CR is a secret-fix shallow profiled insulated roof panel with raised side joints. This panel is ideal for all curved roof

More information

Product Data Sheet. Product: Benchmark Wall Liner System

Product Data Sheet. Product: Benchmark Wall Liner System APPLICATION The Benchmark Wall Liner system is to be used as an insulated composite wall panel under site applied fully supported or self-supported aluminium, copper, zinc and stainless steel cladding

More information

KS1000TS Trapezoidal EcoSafe Insulated Tile Support Roof Panel

KS1000TS Trapezoidal EcoSafe Insulated Tile Support Roof Panel Product Data Sheet Product: KS1000TS Trapezoidal EcoSafe Insulated Tile Support Roof Panel APPLICATION The KS1000TS Trapezoidal EcoSafe Insulated Tile Support Roof Panel is a through fixed roof panel system

More information

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal Insulated Wall Panel KS1000 RW

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal Insulated Wall Panel KS1000 RW Insulated Roof & Wall Panels Solutions Insulated Wall Panel KS1000 RW Applications The KS1000 RW is a metre wide through-fix trapezoidal profiled insulated wall panel which is ideal for both horizontal

More information

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panel KS1000 RW

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panel KS1000 RW Insulated Roof & Wall Panels Insulated Roof Panel KS1000 RW Applications The KS1000 RW is a through-fix trapezoidal profiled insulated roof panel which can be used for building applications with roof pitches

More information

Hip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation

Hip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation Hip Detail Hip Detail STANDARD Mineral fibre insulation ENHANCED Hip flashing with 150mm sealed butt straps Panels site cut to suit rake angle Apex dam (Ref: LP1/A) Rake cut profiled filler sealed top

More information

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Topdek Single Ply Insulated Roof Deck KS1000 TD

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Topdek Single Ply Insulated Roof Deck KS1000 TD Insulated Roof & Wall Panels Solutions Single Ply Insulated Roof Deck KS1000 TD Applications The KS1000 TD is a single component, factory pre-engineered roof deck, comprising a high performance single-ply

More information

Core. Thickness. Karrier Panel Thickness (mm) Weight (Kg/m²)*

Core. Thickness. Karrier Panel Thickness (mm) Weight (Kg/m²)* RENDER PANEL Design Wall Series Benchmark Render Panel is a pre-rendered secret fix PIR insulated wall panel. The system can be laid vertically or horizontally. Available Lengths Standard length is 1.8

More information

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal SF Insulated Roof Panel KS1000 RW SF

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal SF Insulated Roof Panel KS1000 RW SF Insulated Roof & Wall Panels Solutions Insulated Roof Panel KS1000 RW SF Applications KS1000 RW SF is a secret-fix, trapezoidal profiled insulated roof panel which can be used for building applications

More information

Core. Thickness. Biological

Core. Thickness. Biological LOUVRE DW Design Wall Series Benchmark Louvre forms part of the Design Wall Series. It is a secret fix system that can be laid horizontally or vertically giving the appearance of a Louvre Wall. Available

More information

Insulated Roof & Wall Panels. Product Data Sheet. Sinusoidal Insulated Roof Panel KS1000 SRW

Insulated Roof & Wall Panels. Product Data Sheet. Sinusoidal Insulated Roof Panel KS1000 SRW Insulated Roof & Wall Panels Insulated Roof Panel KS1000 SRW Applications The KS1000 SRW is a through-fix sinusoidal profiled insulated roof panel which can be used for building applications with roof

More information

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Trapezoidal Plus KS1000 DLTR PLUS 1.3 & 0.8

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Trapezoidal Plus KS1000 DLTR PLUS 1.3 & 0.8 Fabrications, Safety & Lighting Solutions Kingspan Day-Lite KS1000 DLTR PLUS 1.3 & 0.8 Applications Designed to be an integral part of the Trapezoidal Roof panel system, Kingspan Day-Lite is a range of

More information

ZINC. Product Data Sheet

ZINC. Product Data Sheet ZINC Benchmark Zinc system is available in two different cassette options in a range of finishes and is installed onto a specifically designed Benchmark. Images above courtesy of VMZinc FAÇADE DATA Materials

More information

Product Data Sheet. UltraTemp Insulated Panels for Chilled Storage Applications with a Temperature Range of 0 C to +5 C KS1100 CS

Product Data Sheet. UltraTemp Insulated Panels for Chilled Storage Applications with a Temperature Range of 0 C to +5 C KS1100 CS Product Data Sheet UltraTemp Insulated Panels for Chilled Storage Applications with a Temperature Range of 0 C to +5 C Product Data Sheet Applications UltraTemp insulated roof, wall and ceiling panels

More information

ACM. Product Data Sheet

ACM. Product Data Sheet ACM Benchmark Aluminium Composite Material (ACM) façade system, is available in three cassette options and installed on a specifically designed Benchmark. Images above courtesy of Alucobond FAÇADE DATA

More information

Product Data Sheet. QuadCore Karrier. Applications

Product Data Sheet. QuadCore Karrier. Applications Applications The Quad Karrier system is face fixed, provides the support, thermal and weathering functions to the Benchmark facades. The panel can be laid horizontally or vertically. Suitable for all building

More information

Insulated Roof & Wall Panels Solutions. Product Data Sheet. X-Dek Multi-Span Insulated Roof Panel KS1000 XD Multi-Span

Insulated Roof & Wall Panels Solutions. Product Data Sheet. X-Dek Multi-Span Insulated Roof Panel KS1000 XD Multi-Span Insulated Roof & Wall Panels Solutions X-Dek Insulated Roof Panel KS1000 XD Dimensions, Weight & Thermal Performance X-Dek 50 X-Dek 70 Core Thickness (mm) 46 66 Overall Thickness (mm) 154 174 U-value (W/m²K)

More information

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS INTRODUCTION BENCHMARK Wall Liner is an engineered insulated panel system that is ideal for fully supporting single skin metal sheeting such as zinc,

More information

QuadCore Controlled Environment Series Food Processing Datasheet

QuadCore Controlled Environment Series Food Processing Datasheet Insulated Panel Envelope Systems Roof Wall Façades Lighting Rooftop PV Steel Coldstore Cleanrooms UK & Ireland QuadCore Controlled Environment Series Food Processing Datasheet UltraTemp Insulated Panels

More information

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS Controlled Environments Controlled Environment Panel System KS1100 CS Overview Kingspan controlled environment panel systems are designed for use within temperature controlled and hygiene safe environments

More information

BENCHMARK KREATE FAÇADE & ROOF SYSTEMS

BENCHMARK KREATE FAÇADE & ROOF SYSTEMS Kreate without Compromise BENCHMARK KREATE FAÇADE & ROOF SYSTEMS THE FIRST TRULY INTEGRATED FAÇADE SYSTEM A revolutionary development in metal façade systems, BENCHMARK Kreate is set to transform the

More information

Controlled Environments. KS1100 CS Data Sheet. Controlled Environment Panels. Insulated Panels

Controlled Environments. KS1100 CS Data Sheet. Controlled Environment Panels. Insulated Panels Controlled Environments KS1 CS Data Sheet Controlled Environment Panels Insulated Panels KS1 CS Technical Data Product Overview Kingspan Controlled Environment panels are designed for use within temperature

More information

Insulated Panels. CI/SfB. January CurveWall & Louvre. Architectural Wall Panel Systems. Approved to LPS 1181 Certificate No.

Insulated Panels. CI/SfB. January CurveWall & Louvre. Architectural Wall Panel Systems. Approved to LPS 1181 Certificate No. Insulated Panels CI/SfB (4-) Rh2 January 2010 INSULATED WALL SYSTEMS CurveWall & Louvre Architectural Wall Panel Systems Approved to LPS 1181 Certificate No. 186a & 260a The paper we have printed on is

More information

BENCHMARK Evolution Axis

BENCHMARK Evolution Axis Sheet List EVO VT 00 B DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL

More information

Standing Seam Systems. NBS Specification. KingZip SF Standing Seam Roofing System

Standing Seam Systems. NBS Specification. KingZip SF Standing Seam Roofing System NBS Specification KingZip SF Standing Seam Roofing System H31 METAL PROFILED/FLAT SHEET CLADDING/COVERING To be read with Preliminaries/General conditions. TYPE OF CLADDING SYSTEM 140 METAL PROFILED CLADDING

More information

Cleanroom Systems UltraTech

Cleanroom Systems UltraTech Cleanroom Systems UltraTech High Specification Cleanroom Systems Technical Data Sheets System Overview The UltraTech systems from Kingspan offer the ultimate in cleanroom solutions, satisfying the most

More information

Insulated Roof & Wall Panels. Foilback KS1000 FB Insulated Roof Panels. Product Data Sheet

Insulated Roof & Wall Panels. Foilback KS1000 FB Insulated Roof Panels. Product Data Sheet Insulated Roof & Wall Panels Foilback KS1000 FB Insulated Roof Panels Overview Kingspan Foilback is supplied with a pre-painted Steel external (Aluzinc also available on request) with a choice of silver

More information

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Upstand KS1000 DLU

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Upstand KS1000 DLU Fabrications, Safety & Lighting Solutions Kingspan Day-Lite KS1000 DLU Applications Kingspan Day-Lite is a factory-assembled polycarbonate upstand rooflight integrated into an insulated roof panel, which

More information

Insulated Panels. Insulated Roof Systems. Kingspan X-dek. KS1000 XD Longspan Roofpanel. Systems. Insurer Approved

Insulated Panels. Insulated Roof Systems. Kingspan X-dek. KS1000 XD Longspan Roofpanel. Systems. Insurer Approved Insulated Panels 02 2010 Insulated Roof Systems Kingspan X-dek KS1000 XD Longspan Roofpanel Insurer Approved Systems X dek TM Frame-to-Frame Long Spanning Insulated Roof Deck X dek TM is an insulated roof

More information

Kingspan Day-Lite Kapture Data Sheet

Kingspan Day-Lite Kapture Data Sheet Light + Air UK & Republic of Ireland Kingspan Day-Lite Data Sheet KS700DLK, KS1400DLK, KS0DLK 2 Kingspan Day-Lite KS700DLK, KS1400DLK, KS0DLK Application KS700DLK, KS1400DLK, KS0DLK & KS2750DLK rooflights

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. A comprehensive waterproofing system comprising two reinforced bituminous membranes fully adhered to thermal

More information

4257M METALCRAFT INSULATED PANEL SYSTEMS

4257M METALCRAFT INSULATED PANEL SYSTEMS 4257M METALCRAFT INSULATED PANEL SYSTEMS 1. GENERAL This section relates to the fabrication, supply and installation of prepainted steel clad, insulating panels and cladding system for ambient controlled

More information

Insulated Panel Systems. 1, d0 IND E N 1350

Insulated Panel Systems. 1, d0 IND E N 1350 Insulated Panel Systems DING TO OR 1, d0-1 ACC IND E N 1350 1 Project: TransWest nv, Kampveldstraat 45, 8020 Oostkamp, Belgium Use: Logistical platform with a negative temperature Technical Information

More information

MANUFACTURING TOLERANCES FOR PROFILED METAL ROOF AND WALL CLADDING

MANUFACTURING TOLERANCES FOR PROFILED METAL ROOF AND WALL CLADDING CI/SfB (4-) Rh2 MAY 2006 MANUFACTURING TOLERANCES FOR PROFILED METAL ROOF AND WALL CLADDING Contents Page 1.0 General 1 2.0 Methods for measuring tolerances 2 2.1 Sheet length 2 2.2 Sheet cover width,

More information

Sandwich panel SPA Product description

Sandwich panel SPA Product description Sandwich panel SPA Product description Ruukki offers a sandwich panel system that combines an attractive appearance with excellent thermal insulation and fire-resistance. The panels are of a lightweight,

More information

Architectural Wall Panels (AWP) KS CX/EB/FL/FL-S/ MR/MM/PL/WV KS1000 CW/LV/TL

Architectural Wall Panels (AWP) KS CX/EB/FL/FL-S/ MR/MM/PL/WV KS1000 CW/LV/TL Architectural Wall Panels (AWP) KS600-1000 CX/EB/FL/FL-S/ MR/MM/PL/WV Insulated Roof & Wall Panels Installation Guide November 2017 Architectural Wall Panel Primary / Main fastener Non-setting gun-grade

More information

Insulated Roof & Wall Panels. Daylighting Systems. Natural Light Translucent Polycarbonate Systems

Insulated Roof & Wall Panels. Daylighting Systems. Natural Light Translucent Polycarbonate Systems Insulated Roof & Wall Panels Daylighting Systems Natural Light Translucent Polycarbonate Systems Daylighting Systems Kingspan provides daylighting solutions that deliver the optimum balance between energy

More information

Insulated Panel System. QuadCore IND. Superior FIRE Protection. Unrivalled THERMAL Efficiency. ENHANCED Environmental Credentials

Insulated Panel System. QuadCore IND. Superior FIRE Protection. Unrivalled THERMAL Efficiency. ENHANCED Environmental Credentials 1 Superior FIRE Protection 2 Unrivalled THERMAL Efficiency 3 ENHANCED Environmental Credentials 4 Longest Performance GUARANTEE Insulated Panel System QuadCore IND Technical Information Projet / Usage

More information

Hoesch isodach integral Technical information

Hoesch isodach integral Technical information Technical information A company of ThyssenKrupp Steel tk Contents Page General 3 Main dimensions and properties 4 Corrosion protection 5 Thermal protection / Insulating core 5 Fire protection 5 Information

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. TYPES OF COVERING 110 BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Substrate: Plywood to

More information

B5 for garages, equestrian and other single storey buildings

B5 for garages, equestrian and other single storey buildings Cl/SfB l (4-) l Nf9 l March 2017 l B5 for garages, equestrian and other single storey buildings Corrugated sheet and accessories www.cembrit.co.uk Cembrit companies have been manufacturing corrugated sheets

More information

Corrugated sheet for single storey, sectional buildings and stables

Corrugated sheet for single storey, sectional buildings and stables Cl/SfB l (4-) Nf9 l l September 2011 l Corrugated sheet for single storey, sectional buildings and stables B5 Corrugated sheet and accessories Cembrit companies have been manufacturing corrugated sheets

More information

Type II Environmental Declaration according ISO 14021:2001/A1:2011

Type II Environmental Declaration according ISO 14021:2001/A1:2011 Type II Environmental Declaration according ISO 14021:2001/A1:2011 Product: Hunter Douglas Panels Module 200-600mm Product code: 26005 Module 601-900mm Product code: 26025 Module 901-1200mm Product code:

More information

August Corus Colors. Colorcoat. Technical Paper. Creating an air-tight building envelope

August Corus Colors. Colorcoat. Technical Paper. Creating an air-tight building envelope August 2007 Corus Colors Colorcoat Technical Paper Creating an air-tight building envelope Corus and Part L Over 40 years, Corus has developed close strategic relationships with a number of market-leading

More information

TR26 LPC/FM / TR27 LPC/FM

TR26 LPC/FM / TR27 LPC/FM Insulation A4/8 TR26/27 AW2163 Issue 2 Jan 2017 TR26 LPC/FM / TR27 LPC/FM INSULATION FOR WATERPROOFED FLAT ROOFS Super high performance rigid thermoset insulation LPCB approved to LPS 1181: Part 1 FM approved

More information

Code Compliance Research Report CCRR-0228

Code Compliance Research Report CCRR-0228 Code Compliance Research Report CCRR-0228 Issue Date: 05-09-2017 Renewal Date: 05-11-2018 Revision Date: 06-23-2017 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 40 00 Roofing and Siding

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC. 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL

More information

SECTION METAL ROOF PANELS

SECTION METAL ROOF PANELS SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof

More information

JI WALL 1150 Insulated panels (PIR core)

JI WALL 1150 Insulated panels (PIR core) JI WALL 1150 Insulated panels (PIR core) Index JI Wall 1150 1 Description 2 Weight and thermal performance 2 Materials 3 A1. External weather sheet 3 A2. Internal liner sheet (Liner profile) 3 A3. Insulation

More information

Trisomet External roof and wall panel system

Trisomet External roof and wall panel system Uniclass L5221:P41 CI/SfB (-4) December 2014 Nh2 Trisomet External roof and wall panel system Contents 4-5 Introduction and benefits 6 Platinum Plus system guarantee 7 Colorcoat products and services 8-10

More information

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces. Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces. BRANZ Appraised No. 678 Ref: P3200 Rev 1 February 2016 Page 1 of 5 1.0 PREAMBLE:

More information

Kingspan Day-Lite Klick

Kingspan Day-Lite Klick Insulated Panel Envelope Systems Roof Wall Façades Lighting Rooftop PV Coldstore Structural Products Cleanrooms UK & Ireland Kingspan Day-Lite Klick Installation Guide Page 2 Accessories Overview Designation

More information

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED ConquererTM Panel Products Introduction ConquerorTM International Ltd is New Zealand s only manufacturer

More information

(Project Location) (your firm's name)

(Project Location) (your firm's name) SECTION 07 21 00 THERMAL INSULATION PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the Conditions of the Contract and Division 01 Specification Sections

More information

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Alply CLASSIC WALL Architectural Insulated Panel Wall System SECTION 07 42 13 INSULATED METAL WALL PANELS ALPLY Insulated Panels Alply CLASSIC WALL Architectural Insulated Panel Wall System PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Smooth, non-embossed steel, insulated

More information

Western States 7/8 Corrugated

Western States 7/8 Corrugated Western States 7/8 Corrugated Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

HP Partial Fill. Robust, long-lasting protection

HP Partial Fill. Robust, long-lasting protection 1 CONSTRUCTION TYPE: cavity walls HP Partial Fill Cavity Walls Robust, long-lasting protection HP Partial Fill slabs have a robust outer surface, designed to withstand on-site rigours and maintain a clearly

More information

INSULATED PANELS. Roof & Wall

INSULATED PANELS. Roof & Wall INSULATED PANELS Roof & Wall Table of Contents 0 0 0 06 07 09 6 7 8 9 9 Introduction Production Technology EIP Panel Benefits Products Material Specifications Roof Panel / EIP TRP 0/ Roof Panel / EIP TRP

More information

D Side lap. Side lap screw spacing < 500mm factory-installed seals on side lap. Decoupling tape > 60mm

D Side lap. Side lap screw spacing < 500mm factory-installed seals on side lap. Decoupling tape > 60mm 25 Side lap screw spacing < 500mm 333.3 15 42 Decoupling tape > 60mm 3 factory-installed seals on side lap Side lap D 201.1 SECTION VIEWS Type L Ridge profile Type R Ridge flashing FLOOR PLAN > 200 overlap

More information

PowerDeck F. PIR insulation for Warm Flat Roofs. Product Guide

PowerDeck F. PIR insulation for Warm Flat Roofs. Product Guide PowerDeck F PIR insulation for Warm Flat Roofs. Product Guide Introduction The Company. Driven by a culture of innovation, technical competence and flair, Recticel Insulation Products is dedicated to raising

More information

Insulated Roof & Wall Panels. Kingspan K-Dek Product Guide. Kingspan K-Dek (KS1000 KD) High Performance Insulated Membrane Roofdeck System

Insulated Roof & Wall Panels. Kingspan K-Dek Product Guide. Kingspan K-Dek (KS1000 KD) High Performance Insulated Membrane Roofdeck System Insulated Roof & Wall Panels Kingspan K-Dek Product Guide Kingspan K-Dek (KS1000 KD) High Performance Insulated Membrane Roofdeck System Kingspan K-Dek Insulated Membrane Roofdeck Kingspan K-Dek is an

More information

Thermal Laminate Board.

Thermal Laminate Board. Thermal Laminate Board www.speedlinedrywall.co.uk The Dry Lining and Thermal Insulation Solution The Dry Lining and Thermal Insulation Solution Around a third of all heat lost within un-insulated or poorly

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 GENERAL REQUIREMENTS 185 FRAMING 185 PLASTERBOARD LAYOUT 189 PLASTERBOARD FIXING 190 EXTERIOR

More information

RS32 Multi-Section Skylight System under/over seam clip double diverter

RS32 Multi-Section Skylight System under/over seam clip double diverter INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series

More information

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 1 Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) PRODUCT DESCRIPTION This Detail Sheet relates to Xtratherm Thin-R Partial Fill Cavity Wall Board, as

More information

Alfa Roof 40/3-40/10-40/25

Alfa Roof 40/3-40/10-40/25 Alfa Roof 40/3-40/10-40/25 Structural mechanical properties Alfa Roof 40/3-10-25 sheeting comes in excellent, practical shapes and sizes, designed to meet the specific roofing application needs of industrial

More information

Roof System KS1000 X-dek. Product Data. Application. Dimensions & Weight. Product Tolerances. Available Lengths

Roof System KS1000 X-dek. Product Data. Application. Dimensions & Weight. Product Tolerances. Available Lengths KS1000 X-ek Prouct ata Application X-ek panels are insulate membrane covere roof panels suitable for flat roofs for all builing applications except where there are low temperature internal conitions. The

More information

COMPOSITE PANEL ROOFLIGHTS - FAIRS

COMPOSITE PANEL ROOFLIGHTS - FAIRS www.brettmartin.com COMPOSITE PANEL ROOFLIGHTS - FAIRS Introduction 2 3 Save energy with natural daylight Daylight not only improves the internal environment of a building but, also significantly impacts

More information

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only) Outline NBS Specification Protec System to PVC Single Ply (Waterproofing Only) This document is a guide to assist in the production of tender documents only and is not project specific. A site survey is

More information

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS Insulation A4/8 K12 AW2194 Issue 10 Sep 2017 INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS Super high performance rigid thermoset phenolic insulation Fibre-free, closed cell insulation core Can

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

K12 Framing Board. Insulation

K12 Framing Board. Insulation Insulation A4/8 K12 AW2161 Issue 7 Dec 2016 INSULATION FOR USE BEHIND wall lining AND FRAMED WALLS Super high performance rigid thermoset phenolic insulation Fibre-free, closed cell insulation core Can

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV

More information

Guidance document GD 20 April 2015 amended May 2017 GUIDANCE DOCUMENT ON SERVICEABILITY STATES AND DEFLECTION CRITERIA

Guidance document GD 20 April 2015 amended May 2017 GUIDANCE DOCUMENT ON SERVICEABILITY STATES AND DEFLECTION CRITERIA Guidance document GD 20 April 2015 amended May 2017 GUIDANCE DOCUMENT ON SERVICEABILITY STATES AND DEFLECTION CRITERIA 1 INTRODUCTION The Metal Cladding and Roofing Manufacturers Association had noticed

More information

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION 07530CP EPDM MEMBRANE ROOFING PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL

More information

CS-100 Guide Specifications

CS-100 Guide Specifications MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification

More information

Industry Standard Terms & Definitions Of The Steel Deck Institute

Industry Standard Terms & Definitions Of The Steel Deck Institute Industry Standard Terms & Definitions Of The Steel Deck Institute A specialized set of jargon to describe common terms used by manufacturers and other professionals associated with the usage of Steel Deck

More information

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION PRE-ENGINEERED BUILDING INSULATION PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered

More information

CLASSIFICATION OF FIRE RESISTANCE IN ACCORDANCE WITH BS EN : A1:2009

CLASSIFICATION OF FIRE RESISTANCE IN ACCORDANCE WITH BS EN : A1:2009 Page 1 of 11 CLASSIFICATION OF FIRE RESISTANCE IN ACCORDANCE WITH BS EN 1501-2:2007 + A1:2009 Sponsor: Notified body number: Product name: Classification report number: Kingspan Limited ISOCAB France SAS-France

More information

Cold Storage. Controlled Environments. CLEANsafe Solutions designed for the most demanding Controlled Environments

Cold Storage. Controlled Environments. CLEANsafe Solutions designed for the most demanding Controlled Environments Cold Storage Controlled Environments Solutions designed for the most demanding Controlled Environments Cold Storage Finishes Kingspan Controlled environments take many different forms and the performance

More information

ROOF RENOVATION OVERSHEETING SYSTEM

ROOF RENOVATION OVERSHEETING SYSTEM CI SfB (4-) Nn2 ROOF RENOVATION OVERSHEETING SYSTEM BBA BRITISH BOARD OF AGREMENT CERTIFICATE NO. 87 / 1823/C Renovation Oversheeting System The system has been developed using the proven Onduline weathering

More information

INSULATED PANEL OVERVIEW

INSULATED PANEL OVERVIEW INSULATED PANEL OVERVIEW Our various series of wall and roof panels are filled with non CFC polyisocyanurate foam. The panels are manufactured in a uniform pressure laminating process that bonds metal

More information

AirSmart. The intelligent choice in airtight systems. Superior strength and quality. Energy saving and cost effective. Reduces condensation risk

AirSmart. The intelligent choice in airtight systems. Superior strength and quality. Energy saving and cost effective. Reduces condensation risk AirSmart Superior strength and quality Energy saving and cost effective Reduces condensation risk Enhances thermal performance Complete airtight solution The intelligent choice in airtight systems The

More information

URSA 20 Plus and URSA 20

URSA 20 Plus and URSA 20 URSA GLASSWOOL E-mail : ursauk@uralita.com URSA UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk E-mail

More information

Guide Specification SDP 200

Guide Specification SDP 200 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sheet metal roofing panels, metal trim, accessories, fasteners, closures, and sealants. [Specifier Note: Edit paragraph below to suit project requirements.]

More information

Brick Veneer Walls. Insulation

Brick Veneer Walls. Insulation Insulation A4/8 BV AW2157 Issue 7 Nov 2016 Brick Veneer Walls Insulation guide Helps achieve a 6-star house energy rating Rigid Kingspan Kooltherm and flexible Kingspan AIR-CELL solutions available Fibre-free,

More information

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE DIVISION 13 - SPECIAL CONSTRUCTION SECTION 13080 - ACOUSTICAL PANEL ENCLOSURE 1 GENERAL 1.01 SUMMARY A. ACOUSTIC ENCLOSURE CONSISTING OF WALLS, CEILING, STRUCTURAL FRAMING, CONNECTING MEMBERS, DOORS, WINDOWS,

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2218 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00

More information

Choosing & using. Customer Services Tel Fax

Choosing & using. Customer Services Tel Fax CI/SfB (4-) Rf9 January 2013 Choosing & using Customer Services Tel 01283 722588 Fax 01283 722219 E-mail info@marleyeternit.co.uk www.marleyeternit.co.uk Marley Eternit Limited, Lichfield Road, Branston

More information

PRE-ENGINEERED METAL BUILDING SYSTEM

PRE-ENGINEERED METAL BUILDING SYSTEM PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,

More information

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate

More information

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION Insulation A4/6 TB055F AW2002 Issue 4 Sept 2015 THERMO REFLECTIVE INSULATION Innovative cross-linked closed-cell insulation core Improved Class 0 fire performance to stringent international standards 3-in-1

More information

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of

More information

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION Insulation A4/6 TB055W AW2244 Issue 6 Oct 2017 WHITE-FACED THERMO REFLECTIVE INSULATION Innovative cross-linked closed cell insulation core 3-in-1 Insulation, vapour barrier and radiant barrier Helps achieve

More information

Page 1 of 5

Page 1 of 5 SPECIFICATIONS COMPOSITE MATERIAL PANEL SYSTEM ESTOLGA 1000 DRY SEAL SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary

More information