RETHINK METAL FRAMING

Size: px
Start display at page:

Download "RETHINK METAL FRAMING"

Transcription

1 RETHINK METAL FRAMING StudRite FrameRite connectors FASTrack QuickFrame JoistRite GenieClip

2 RETHINK WALL FRAMING StudRite weighs less than traditional studs making it easier to handle. The unique design is more user-friendly and requires less time to finish the job right. The versatile StudRite wall system adds increased efficiencies, making it the best tool for the trade. Less Weight Less Time More Design Flexibility Tall Walls Fire Rated Fewer Callbacks Sound Tested Great for Trades Excellent for Panelizers StudRite Demo!

3 RETHINK FIRE CAULKING TRACK 1000 Factory-installed intumescent on FAS Track 1000 means faster framing for the contractor and no fire caulk needed. Work faster with FAS Track Costs Less No Sealant Needed Code Compliant Sound Tested Fire Rated Air Leakage Rated Slotted Track Deep Leg Track J-Track FASTrack Demo!

4 RETHINK FLOOR FRAMING JoistRite weighs less than traditional joists which makes it easier to handle. The unique design is more user-friendly and requires less time to finish the job right. The versatility of JoistRite floor systems means increased efficiencies, making it the best tool for the trade. Less Weight Large Knockouts More Design Flexibility Precise Length Fire Rated Fewer Callbacks Sound Tested Easy Handling Great for Trades JoistRite StudRite Demo!

5 RETHINK CONNECTORS Marino/Ware designed FrameRite Connectors to significantly reduce time, labor, materials and costs. FrameRite Connectors facilitate quicker, more cost-effective installation which make them the best tools for the trade. Less Cost Less Time Load Rated Bridging Clips Rigid Clips Clip Angles Slide Clips Joist Hangers Sound Clips FrameRite Demo!

6 RETHINK HEADERS Rough Opening System The QuickFrame Rough Opening System streamlines installation by reducing the number of components required to frame windows and doors. QuickFrame allows for quicker, more cost-effective installation which makes it the best tool for the trade. Increased Performance Less Weight Fewer Pieces Eliminates Build-Up Jambs Eliminates Build-Up Headers 50% Labor Reduction Pre-Drilled Holes Pre-Cut Lengths One Piece Clips Snap here for a a 3D 3D JoistRite QuickFrame Demo!

7 RETHINK ACOUSTICS The GenieClip is engineered to reduce the transmission of airborne and impact sound through wall and floor/ceiling assemblies. The GenieClip s unibody construction translates to reduced assembly weight, making it the best tool for the trade. Increased Performance Less Weight 150 Lab and Field Tests Galvanized Steel Mount Molded Rubber Unibody 40 UL Certifications Installation Stability Reduces Gypsum Required High Load Capacity GenieClip Demo!

8 New Jersey Facility 400 Metuchen Road South Plainfield, NJ Fax: Georgia Facility 777 Greenbelt Parkway Griffin, GA Fax: Indiana Facility 4245 Railroad Avenue East Chicago, IN Fax: Texas Facility Bay Area Boulevard Pasadena, TX Fax: New York Sales Office 137 Broadway, Suite B1 Amityville, NY Fax: Engineering Office 100 Hendrick Drive, Suite 200 McDonough, GA Fax: For more information, please contact Marino\WARE Technical Services at This technical information reflects the most current information available and supersedes any and all previous publications effective May 25, 2017 WARE Industries, Inc. 2017

It s not magic, it s engineering. Impact and Airborne Sound Control. GenieClip. US Patent No. 7,895,803

It s not magic, it s engineering. Impact and Airborne Sound Control. GenieClip. US Patent No. 7,895,803 It s not magic, it s engineering. Impact and Airborne Sound Control GenieClip US Patent No. 7,895,803 GenieClip An innovative, and reliable sound solution Engineered for superior acoustical performance

More information

Shaftwall and Area Separation Wall Systems.

Shaftwall and Area Separation Wall Systems. Shaftwall and Area Separation Wall Systems www.marinoware.com Marino\WARE S Fire Rated Wall Systems Quality that takes you to the top. Marino\WARE created its CT Shaftwall System, to be a flexible shaftwall

More information

Marino\WARE Cold-Rolled Steel Framing Systems

Marino\WARE Cold-Rolled Steel Framing Systems Name Marino\WARE Cold-Rolled Steel Framing Systems Product ID Classification 05 40 00.00 Metals (beams): Cold- Formed Metal Framing Website www.marinoware.com Manufacturer Address Marino\WARE 100 Hendrick

More information

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

AND ACCESSORIES FOR DRYWALL CONSTRUCTION STEEL TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION Quality in your corner. THE STRENGTH WITHIN MONTREAL TORONTO CALGARY EDMONTON VANCOUVER STEEL TRIMS AND ACCESSORIES for Construction BAILEY HAS YOUR

More information

The Perfect Choice for Mezzanines in Custom Metal Buildings

The Perfect Choice for Mezzanines in Custom Metal Buildings The Perfect Choice for Mezzanines in Custom Metal Buildings Ecospan composite floor system. The Ecospan Composite Floor System is an innovative, simple, effective and economical method of providing all

More information

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000? TRACK 1000 FIRE MANAGEMENT PRODUCTS TECHNICAL PRODUCT GUIDE www.cemcosteel.com WHY I SHOULD SPECIFY AND USE FAS TRACK 1000? SOUND BENEFITS: Whether the protection you need is Fire, Air (Smoke), or Sound

More information

Installation Guide and Safety Manual

Installation Guide and Safety Manual Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips) REQUIRED FURRING CHANNEL REQUIRED FURRING CHANNEL* 1 4" 2 2" Minimum f" Gauge:...25 Gauge With Hemmed Edge (Do Not

More information

Pliteq Inc. - LEED Summary

Pliteq Inc. - LEED Summary Pliteq Inc. - LEED Summary At Pliteq, we re committed to serving the health and safety of both our environment and our community. Pliteq is an engineering company dedicated to providing creative solutions

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

Utility Cabinet System (UCS)

Utility Cabinet System (UCS) (UCS) The Ultimate in Stainless Steel Modular Walls UCS: Eliminates the need and the costs of constructing a traditional wall Provides easier access and faster installation of the utilities compared to

More information

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD AND TRACK FOR DRYWALL PARTITIONS TAKE ADVANTAGE OF THE SAVINGS IN TIME

More information

BEARING METAL STUD FRAMING

BEARING METAL STUD FRAMING L-1 Section 05410 Long Form Specification LOAD BEARING METAL STUD FRAMING This section includes axially loaded steel studs, with unique slotted top channels, usually of 0.91, 1.2 and 1.5 mm (16, 18, or

More information

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO SECTION 09265 - GYPSUM BOARD SHAFT-WALL ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 22 16 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS

ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS 13080/KIN BuyLine 1062 Providing solutions to common noise and vibration problems since 1958. ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS IIC 51 STC 72 FLOOR/CEILING STC 84 IIC 70 FLOOR/CEILING

More information

Cavity ShAftwall System

Cavity ShAftwall System 09 9 00/NGC Cavity shaftwall systems are non-load-bearing, -hour to -hour, fire-rated partitions constructed from one side used to enclose elevator shafts, stairs and mechanical shafts where the design

More information

ICFs. Insulating Concrete Forms. Shorten Construction Schedule Enhance Comfort and Safety Reduce Energy Costs

ICFs. Insulating Concrete Forms. Shorten Construction Schedule Enhance Comfort and Safety Reduce Energy Costs ICFs Shorten Construction Schedule Enhance Comfort and Safety Reduce Energy Costs Build An Environmentally Friendly Home Add up residential heating and cooling, lighting, appliances and other electronic

More information

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

Retain Preinstallation Conference Paragraph below if Work of this Section is extensive or complex enough to justify a conference. SECTION 05 40 00 - COLD-FORMED METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

HAMBRO COMPOSITE FLOOR SYSTEM

HAMBRO COMPOSITE FLOOR SYSTEM HAMBRO COMPOSITE FLOOR SYSTEM OUR EXPERTISE AT YOUR SERVICE Canam has been offering owners, real estate developers, architects, engineers and contractors an array of construction solutions since 1970.

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD SECTION 09250 GYPSUM BOARD PART 1GENERAL 1.1 SUMMARY A. Related Documents: General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and Drawings are collectively applicable

More information

RESILIENT SOUND ISOLATION CLIPS

RESILIENT SOUND ISOLATION CLIPS RESILIENT SOUND ISOLATION CLIPS For Wall & Floor Ceiling Assemblies RSIC-1 Resilient Sound Isolation Clip Isolation Clip RSIC-1 Isolation Clip Soundproofing Products SonexTM Ceiling & Wall Panels Sound

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

ALL-ALUMINUM DOOR & WINDOW FRAMING

ALL-ALUMINUM DOOR & WINDOW FRAMING ALL-ALUMINUM DOOR & WINDOW FRAMING WITH INTEGRATED ALUMINUM DOOR STOP SECTION 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONTS SPECIFICATION PART 1 GENERAL 1.1 SECTION INCLUDES: A. Prefinished aluminum

More information

REPORT HOLDER: WARE INDUSTRIES, INC. (DBA Marino\WARE) 400 METUCHEN ROAD SOUTH PLAINFIELD, NEW JERSEY EVALUATION SUBJECT:

REPORT HOLDER: WARE INDUSTRIES, INC. (DBA Marino\WARE) 400 METUCHEN ROAD SOUTH PLAINFIELD, NEW JERSEY EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2620 Reissued 07/2017 This report is subject to renewal 07/2019. DIVISION: 05 00

More information

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD ASSEMBLIES SECTION 09 21 16 GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal stud wall and ceiling framing, 20 gauge. B. Metal channel suspended ceiling framing. C. Gypsum board. D. Gypsum sheathing.

More information

TYPICAL BEARING WALL FRAMING

TYPICAL BEARING WALL FRAMING BASIC WOOD FRAMING City of Grand Rapids Building Safety Division 218-326-7601 www.grandrapidsmn.org This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code,

More information

ARCHITECTURAL CEILING HANGERS

ARCHITECTURAL CEILING HANGERS , Inc. Manufacturers of Vibration Control Products 350 Rabro Drive 2101 W. Crescent Ave., Suite D Hauppauge, NY 11788 Anaheim, CA 92801 631/348-0282 714/535-2727 FAX 631/348-0279 FAX 714/535-5738 Info@Mason-Ind.com

More information

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866) TECHNICAL NOTE On Cold-Formed Steel Construction $5.00 Light Gauge Steel Engineers Association Washington, D.C. 20005 Toll Free (866) 465-4732 www.lgsea.com DESIGN OF BY-PASS SLIP CONNECTORS IN COLD-FORMED

More information

138 H-STUD AREA SEPARATION WALL SYSTEM

138 H-STUD AREA SEPARATION WALL SYSTEM H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic fashion by the results of this actual townhouse fire in which the two-hour fire-rated

More information

where high efficiency is the standard

where high efficiency is the standard Access Doors 2016 where high efficiency is the standard Experience Milcor offers years of experience in the manufacture of a broad range of products and services for residential, commercial, institutional

More information

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Page 1 or 8 APPLICATION This fi re damper is intended to restrict the passage of fl ame. The standard installation requires that the

More information

SECTION SOUND ISOLATION

SECTION SOUND ISOLATION SECTION 13085 SOUND ISOLATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Resilient sound isolation clips installed with drywall furring channels for support of gypsum board for noise control (de-coupling)

More information

Smarter. Safer. Leaner.

Smarter. Safer. Leaner. Smarter. Safer. Leaner. Fast Installation and Removal Decrease Leading Edge Exposure by 87% OSHA Compliant Versatile and Reusable Use Perimeter Protection Posts During Construction: At Building Perimeter

More information

RSIC-1 SOUND ISOLATION SYSTEMS RSIC-1 INSTALLATION GUIDE

RSIC-1 SOUND ISOLATION SYSTEMS RSIC-1 INSTALLATION GUIDE RSIC-1 INSTALLATION GUIDE PAC International, Inc. Tel: (866) 774-2100 Technical: (866) 649-2710 Web Site: www.pac-intl.com RSIC is a registered Trade Mark of PAC International, Inc. Page 1 Drywall Furring

More information

Knauf MF Suspended Ceilings

Knauf MF Suspended Ceilings Suspended Ceilings The Suspended Ceiling system is versatile and easy to install. Deep voids are easily created to hide services and the ceiling can be used to provide fire protection. Metal Components

More information

SECTION VIBRATION ISOLATION

SECTION VIBRATION ISOLATION SECTION 15240 VIBRATION ISOLATION PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15450 - Plumbing Equipment. 2. 15510 - Piping (HVAC). 3. 15515 Valves, Hangers, and Specialties. 4. 15540 - Pumping

More information

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer... SECTION DIRECTORY General Information Introduction... V250-ID-886 Installation Accessories and Applications... V250-ID-886 Typical Sealant Placement Details... V250-ID-887 Fin Installation Details Wood

More information

The GlasRoc Shaftliner Type X advantage...

The GlasRoc Shaftliner Type X advantage... C e r t a i n T e e d SHAFTLINER F o r A r e a S e p a r a t i o n F i r e w a l l s Shaftliner S Type X for Area Separation GlasRoc Shaftliner is a specially formulated product for applications where

More information

GROUP SWL....Delivering complete storage solutions

GROUP SWL....Delivering complete storage solutions ...Delivering complete Introduction Group is a family run business established in 1979, supplying a wide range of and services throughout the United Kingdom. Our aim is to provide our customers with top

More information

Specifying metal studs for interior and exterior walls can be simple.

Specifying metal studs for interior and exterior walls can be simple. by Thomas Castle, SE Specifying metal studs for interior and exterior walls can be simple. However, openings in the walls for doors, windows, and HVAC ducts require headers, jambs, and sills around them.

More information

AXIOM Indirect Light Coves

AXIOM Indirect Light Coves AXIOM Indirect Light Coves Assembly and Installation Instructions 1. GENERAL 1.1 Description The Axiom Indirect Light Cove system is a pre-engineered lighting solution designed to be used at a ceiling-to-wall

More information

FrameFast Shoring System

FrameFast Shoring System FrameFast FrameFast Shoring System The FrameFast shoring system is engineered for maximum strength, labor productivity and reuse capabilities. FrameFast components feature high strengthto-weight ratios.

More information

SECTION GYPSUM WALLBOARD. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION GYPSUM WALLBOARD. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 092116 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

Ceiling Attenuation Class Systems SYSTEMS 280

Ceiling Attenuation Class Systems SYSTEMS 280 SYSTEMS 280 Ceiling Attenuation Class Ceiling Attenuation Class (CAC) ceiling systems display resistance to sound passing up and over a wall. The sound insulation rating given for the ceiling system indicates

More information

Product Guide Specification

Product Guide Specification PAC International, Inc. December 2007 Las Vegas, NV 89128 Toll Free (866) RSIC-100 (866) 774-2100 Fax (866) 649-2710 Web Site www.pac-intl.com E-Mail info@pac-intl.com Product Guide Specification Specifier

More information

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers. SECTION 05 31 13 STEEL FLOOR DECKING PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 - Specification

More information

Introducing TJ Insulated Structural Framing Components

Introducing TJ Insulated Structural Framing Components #TJ-9009 SPECIFIER S GUIDE TJ INSULATED HEADERS, RIM BoaRD, AND CORNERS Introducing TJ Insulated Structural Framing Components Helps meet the 2011 Federal Energy Star Homes and 2009 International Energy

More information

Installation Instructions

Installation Instructions Installation Instructions RainTight Decks www.raintightdecks.com Underdeck Installation Instructions Table of Contents Page 3 Page 4 Page 5 Page 6 Page 7 Tools Required Introduction and How the system

More information

I-STUD Shaftwall System

I-STUD Shaftwall System I-STUD Shaftwall System Summit Tower I-Stud and CertainTeed Shaftliner TM MILL CERTIFIED Steel-Con 00% GALVANIZED Steel Construction Systems UL Evaluation Report No. ER3660-02 Intertek The I-Stud is approved

More information

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual FORM HEADWALL (floating) Installation Manual FORM HEADWALL (floating) OVERVIEW The Form is a UL-listed configurable headwall system. This system includes multiple horizontal equipment channels integrated

More information

CEILING SYSTEMS. DRYWALL GRID and FRAMING SYSTEM. Between us, ideas become reality

CEILING SYSTEMS. DRYWALL GRID and FRAMING SYSTEM. Between us, ideas become reality CEILING SYSTEMS Between us, ideas become reality DRYWALL GRID and FRAMING SYSTEM Pre-engineered systems from Armstrong are designed so you know what the details of finished installations will look like

More information

Cultivation Rooms. Modular Cleanroom Systems for the Cannabis Industry

Cultivation Rooms. Modular Cleanroom Systems for the Cannabis Industry Cultivation Rooms Modular Cleanroom Systems for the Cannabis Industry Construction Simplified Why Choose Modular? Explore the Benefits of Modular Construction Clean Installation Modular components are

More information

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual FORM HEADWALL (floor mount) Installation Manual FORM HEADWALL (floor mount) OVERVIEW The Form is a UL-listed configurable headwall system. This system includes multiple horizontal equipment channels integrated

More information

SECTION MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS

SECTION MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS SECTION 13096 MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS Prepared by: NELCO 125 Chenoweth Lane, Ste. 206 Louisville, KY 40207 (502) 899-3726 13096-1 MODULAR GALVANIZED RF SHIELDING SYSTEM PART

More information

Benefits.

Benefits. PARTITIONING Systems Stud & Track An economical friction-fit system to assemble frames for strong, compact, lightweight non load-bearing partitions. The metal stud partitioning is ideal for use in domestic

More information

The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary

The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM Expanding spaces to the extraordinary Overview Elevation View of a 4-panel Lift & Slide Door System - Stacked Configuration Panda s Lift & Slide Door Systems

More information

The System Slotted Deflection Track (pat# 5,913,788)

The System Slotted Deflection Track (pat# 5,913,788) The System Slotted Deflection Track (pat# 5,913,788) UBC 1997/CBC 1997 Section 702. Definitions A FIRE-RESISTIVE JOINT SYSTEM is an assemblage of specific materials or products that are designed, tested,

More information

RS24-10 Single-Section Skylight System

RS24-10 Single-Section Skylight System INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980

More information

AREA SEPARATION WALL SYSTEMS

AREA SEPARATION WALL SYSTEMS 13 AREA SEPARATION WALL SYSTEMS Fire-resistance protects lives and property. Area separation walls are non-load bearing, 2-hour and 3-hour rated vertical wall assemblies that provide fire-resistant protection

More information

Area Separation Walls

Area Separation Walls Area Separation Walls G-P Gypsum Your Complete Resource for Innovative Gypsum Products Overview When tested, as manufactured, in accordance with ASTM D 3273, DensGlass Ultra Shaftliner TM panels scored

More information

Jean Vaillancourt Fire Protection Specialist Hilti (Canada) Corp.

Jean Vaillancourt Fire Protection Specialist Hilti (Canada) Corp. Cable Management Firestop Jean Vaillancourt Fire Protection Specialist Hilti (Canada) Corp. FIRESTOPPING KNOWLEDGE FOR BETTER SPECIFICATION AND DESIGN OF FIRE-RATED CONSTRUCTION Presentation Topics and

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Manufacturer's Representative: Rectorseal - Technical Services Ph (713) 263-8001

More information

Post Style with ABS Real Tuff

Post Style with ABS Real Tuff Post Style with ABS Real Tuff Mantova s patented Post Shelving with ABS Real Tuff removable shelves have been making life easier for thousands of Australian businesses for more then a decade. Removable

More information

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions.

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions. 15240 VIBRATION ISOLATION ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 230548 An optional keynote

More information

4-5/8" Offset Projected Architectural Thermal Aluminum Windows. Project In TR-740 (AW-PG80-AP) or Project Out TR-750 (AW-PG80-AP)

4-5/8 Offset Projected Architectural Thermal Aluminum Windows. Project In TR-740 (AW-PG80-AP) or Project Out TR-750 (AW-PG80-AP) 4-5/8" Offset Projected Architectural Thermal Aluminum Windows Project In TR-740 (AW-PG80-AP) or Project Out (AW-PG80-AP) TR-700 Window Wall Multifaceted Window System for Flexible Design The Admiral at

More information

ENGINEERS ENGINEERED SOLUTIONS DEEP-DEK COMPOSITE COMPOSITE LONG SPAN FLOOR DECK.

ENGINEERS ENGINEERED SOLUTIONS DEEP-DEK COMPOSITE COMPOSITE LONG SPAN FLOOR DECK. ENGINEERS ENGINEERED SOLUTIONS DEEP-DEK COMPOSITE COMPOSITE LONG SPAN FLOOR DECK www.metaldek.com DEEP-DEK 4.5 COMPOSITE DEEP-DEK 6 COMPOSITE DEEP-DEK COMPOSITE Deep-Dek Composite* is a long-span composite

More information

Contec is AAC. 1. Contec is AAC

Contec is AAC. 1. Contec is AAC 1. Contec is AAC 1.1 Introduction 1.2 About Contec 1.3 Contec and AAC 1.4 List of Products 1.5 Applications of Contec AAC Products 1.6 Manufacturing Process 1.7 Quality control 1.8 Benefits of Contec AAC

More information

2012 & 2015 International Building Code. Section Section Section Section Section Section 713.4

2012 & 2015 International Building Code. Section Section Section Section Section Section 713.4 Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Assembly Evaluation Report represents a product that Pei ES has Evaluated and has an Assembly Evaluation

More information

Structural Technical Report #2 By Robert Whitaker

Structural Technical Report #2 By Robert Whitaker Structural Technical Report #2 By Robert Whitaker Robert Whitaker Structural ~ Parfitt Parkview at Bloomfield Station Bloomfield, NJ 10-31-05 Executive Summary This report covers the comparative redesign

More information

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems.

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems. SECTION 09 51 13 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Patent No. 9,045,900 Technical Glass Products Architectural Specification Manual

Patent No. 9,045,900 Technical Glass Products Architectural Specification Manual Technical Glass Products Architectural Specification Manual 800.426.0279 fireglass.com FIREFRAMES ALUMINUM SERIES INTERIOR APPLICATION ONLY Fireframes Aluminum Series combined with Pilkington Pyrostop

More information

Built to Order. Stile. Frames. Section Contents. Profiles. Elevations. Double Egress Frames Pocket Frames

Built to Order. Stile. Frames. Section Contents. Profiles. Elevations.  Double Egress Frames Pocket Frames Frames Section Contents General Frame Construction Profiles F-1.0 Typical Jamb & Sill Profiles F-2.0-2.1 Frame Welding Elevations F-3.0 Frame Elevations F-4.0-4.2 Custom Frame Elevations Panel Types +

More information

Fabline Modular Cleanroom Wall Systems For The Most Demanding Cleanroom Requirements

Fabline Modular Cleanroom Wall Systems For The Most Demanding Cleanroom Requirements C l e a n r o o m W a l l S y s t e m s Fabline Modular Cleanroom Wall Systems For The Most Demanding Cleanroom Requirements Innovative Industries Demand Flexibility FabLine modular cleanroom wall systems

More information

Tate Strut. Steel Structural Ceiling Grid System for Data Centres. Metric Edition

Tate Strut. Steel Structural Ceiling Grid System for Data Centres. Metric Edition Tate Strut Steel Structural Ceiling Grid System for Data Centres Metric Edition Tate Strut Steel Structural Ceiling Grid System for Data Centres Tate Strut is the ideal solution for any application where

More information

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components Moduline Acoustic Enclosure System Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components Lab certified acoustic ratings Broad range of performance levels 63 Hz

More information

2.2E Parallam PSL Deep Beam

2.2E Parallam PSL Deep Beam #TJ-7001 SPECIFIER S GUIDE 2.2E Parallam PSL Deep Beam Featuring 20" 24" Deep Trus Joist Parallam PSL Beams Ideal for multi-family and light commercial applications Offers high strength and consistent

More information

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3207 Reissued 10/2016 This report is subject to renewal 10/2018. DIVISION: 09 00 00 FINISHES

More information

SECTION COLD-FORMED METAL FRAMING

SECTION COLD-FORMED METAL FRAMING SECTION 05400 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work of this Section shall include all materials and installation necessary to provide all cold formed metal framing. B. This Section includes:

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system Pizza Express, York 30 Metal framed wall lining system wall lining system is a cost-effective, virtually independent metal frame drylining. It is a general purpose system

More information

GypLyner (walls) Metal framed wall lining system. GypLyner.

GypLyner (walls) Metal framed wall lining system. GypLyner. GypLyner GypLyner (walls) Metal framed wall lining system GypLyner is a cost-effective, virtually independent metal frame drylining system for lining walls. General purpose and suitable for all internal

More information

Fire protection for townhouses that share a common wall. AreaSeparationWall Systems

Fire protection for townhouses that share a common wall. AreaSeparationWall Systems Fire protection for townhouses that share a common wall AreaSeparationWall Systems Area separation walls between adjoining townhouses must provide fire-resistive ratings to ensure the safety of occupants

More information

Weep Valves Stucco Wire Mesh Reinforcement Weather Resistive Barrier Sheathing Insulation Framing

Weep Valves Stucco Wire Mesh Reinforcement Weather Resistive Barrier Sheathing Insulation Framing INSTALLATION INSTRUCTION FOR SINGLE-HUNG AND FIXED WINDOW REPLACEMENT using FLUSH FLANGE Installation Instructions for replacing windows in a Typical Stucco Application. These instructions were developed

More information

Cold-Formed Steel Framing: Engineering the Details of Your Next Project BUILDSTEEL.ORG

Cold-Formed Steel Framing: Engineering the Details of Your Next Project BUILDSTEEL.ORG Cold-Formed Steel Framing: Engineering the Details of Your Next Project Cold-Formed Steel Framing Resource Center for Building Professionals Table of Contents INTRODUCTION 1 How to Engineer Cold-Formed

More information

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control It s not magic, it s engineering. Impact Sound Control GenieMat FF Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation Patents: US 8240430, US8556029, CA 2500956, CA 2503420 GenieMat

More information

MID-RISE DESIGN & CONSTRUCTION

MID-RISE DESIGN & CONSTRUCTION TECHNICAL BULLETIN No.38-021616 Rev072116 MID-RISE DESIGN & CONSTRUCTION Logix effective R-values range from R-24 to R-28+ Insulated concrete forms (ICF) are becoming a main stream choice for the construction

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 095133 - ACOUSTICAL METAL PAN CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society

More information

TOP CAP Snaps into bottom track Aluminum - trimmed to length. RAMPS Covered by carpet ABS plastic and MDF QUESTIONS? CALL US AT !

TOP CAP Snaps into bottom track Aluminum - trimmed to length. RAMPS Covered by carpet ABS plastic and MDF QUESTIONS? CALL US AT ! IN-CARPET WIREWAY INSTALLATION GUIDE 2.7 These components are typical for each wireway installation: WALL BASE TRIM Finishes cable opening at wall BOTTOM TRACK Screws to concrete Aluminum - trimmed to

More information

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Assembly Evaluation Report represents a product that Pei ES has Evaluated. This Assembly Evaluation

More information

Innovation in Steel Collar Fastening Technology - Connecting Steel

Innovation in Steel Collar Fastening Technology - Connecting Steel Innovation in Steel Collar Fastening Technology - Connecting Steel Introduction to Rosette Philosophy and Technology 2003 Thank you for your interest in Rosette technologies, the new-generation in light-gauge

More information

Breeze Modular Atmosphere and Environment

Breeze Modular Atmosphere and Environment Breeze Modular Atmosphere and Environment Breeze Modular Fully demountable, this suite exudes innovation and practicality. The Breeze Modular allows future alterations and extensions to be performed simply

More information

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE DIVISION 13 - SPECIAL CONSTRUCTION SECTION 13080 - ACOUSTICAL PANEL ENCLOSURE 1 GENERAL 1.01 SUMMARY A. ACOUSTIC ENCLOSURE CONSISTING OF WALLS, CEILING, STRUCTURAL FRAMING, CONNECTING MEMBERS, DOORS, WINDOWS,

More information

2.2E Parallam PSL Deep Beam

2.2E Parallam PSL Deep Beam #TJ-7001 SPECIFIER S GUIDE 2.2E Parallam PSL Deep Beam Featuring 20" 24" Deep Trus Joist Parallam PSL Beams Ideal for multi-family and light commercial applications Offers high strength and consistent

More information

H y a t t C e n t e r Chicago, Illinois (71 South Wacker Drive) Acoustics Study

H y a t t C e n t e r Chicago, Illinois (71 South Wacker Drive) Acoustics Study 8.0 Acoustics and Fire Rating Study Introduction An acoustics and fire rating study was performed on the Hyatt Center to establish an acceptable infill wall assembly for use in the proposed braced frame

More information

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS Ideal for applications requiring space division, visibility and security Used in bank lobbies, offices, conference areas, interior storefronts and arena skyboxes

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-10 22 19 (August 2017) --------------------------- Preparing Activity: USACE Superseding UFGS-10 22 19 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge Assembly Manual 8x9 PATENTS ARE PENDING Approximate Size 7640303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth

More information

RSIC-1. RSIC-1, the Low Cost, High Performance, Noise control Solution. RSIC-1 specifications:

RSIC-1. RSIC-1, the Low Cost, High Performance, Noise control Solution. RSIC-1 specifications: RSIC-1 The RSIC-1 is designed for use with any wood framed, steel framed, CMU, or concrete wall and ceiling system where noise control is needed. The RSIC-1 assembly decouples and isolates the gypsum board

More information

LISTING INFORMATION OF ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies SPEC ID: 26662

LISTING INFORMATION OF ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies SPEC ID: 26662 LISTING INFORMATION OF ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies SPEC ID: 26662 ClarkDietrich Building Systems 9100 Centre Pointe Drive, Suite 210

More information

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START CLICK TO START About Knauf Metal Knauf Metal is part of the Knauf Group, leaders in lightweight construction materials, and a major supplier and manufacturer of metal building systems to the Australian

More information